Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure



Similar documents
Buckeye Detection Systems Fixed Detection Systems Application Survey

Ammonia Detection System Codes and Design Specifications

Chapter 9 N.C. C. N.O. Single-Pole Double-Throw

sierra monitor corporation Fire and Gas Detection Systems

PortaSens ll G AS DETECTOR

Fire & Security DETECTORS

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

SECTION DETECTION AND ALARM

Series B14 Monitor System

WD-AMX Water Detection Controllers

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Alarm and Detection/Suppression

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Life Alarm Fire Alarm Controls

Fire Pump Controllers Remote Alarm Panels

Ultima X Series Gas Monitors

Manual for Fire Suppression & Methane Detection System

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Application Requirement

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Lockout Specification BW Clip Maintenance-free single gas detector

MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE

TABLE OF CONTENT

Residential & Commercial Alarm Systems by Gross Security, LLC

SECTION NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS

EXPLORER 4 MULTIPOINT

ALTAIR 5X Multigas Detector Bid Specification

ERS-2400B. PERS-2400B Personal Emergency Reporting System

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

ICP-CP500. User's Guide ICP-CP500 Codepads

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

PowerCode Wireless. Fully supervised wireless system. Features

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

How To Use An Irius Pid Detector

T a b l e o f C o n t e n t s

The Ambient Air Monitoring System

Conventional Fire Detection and Extinguishant Control System Specification

CBD-233. Fire Alarm and Detection Systems

Touchpoint Pro. Flexible Gas Control System

Engineering Specifications XNX Universal Transmitter

Multipoint Scanning Alarm System

Carbon Monoxide (CO) Gas Detection and Control System

SEC 1500 Gas Detector Instruction Manual

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Module 5. Fire and Emergency Alarm System Part I- Basics

ENMET Corporation PO Box 979 Ann Arbor, MI ENG 97D STAND-ALONE MANUAL. Manual Part Number MCN-389, 01/21/08

Triple Waveband Infra-Red Flame Detection

Honeywell Analytics Lines of Business

Self Monitoring Power Supply (BPSM)

S4000TH HART. HART Communication Manual

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Gas and flame detection Stack gas and dust analysis

PowerMaxComplete. All-in-one Professional Grade Wireless Security

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Ammonia Detection System Codes and Design Specifications. Brian EuDaly, P.E. Calibration Technologies, Inc.

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

Solution 880 Operators Manual ISSUE 1.10

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Water Leak Detection System

Module 4, Lesson 12 Fire Alarm Systems

RECON-4 Portable Multi-gas Detector Software Manual

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

SMART SENSOR COLLECTION

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

EXHIBIT A SCOPE OF WORK

Product Guide CM-Relay

Data Logging Solutions from Lascar Electronics

ICP-CC404 ICP-CC404 EN. Control Panel. User s Guide

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

SERIES ͲΝΒΣΞ ΒΟΘΖ Swann 2013

INSTALLATION / OPERATION MANUAL

GC2 Panel User Guide

DUCT SMOKE DETECTOR D4120

integrated fire and security solutions Maximum protection for buildings

Global System Technology(UK) PLC The Intelligent Solution

AC-115 Compact Networked Single Door Controller. Installation and User Manual

DTW Works Master Specification Version 2006

ICP-CC488. Installation Guide ICP-CC488 Control Panel

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Street Smart Home Control

O C M III. Open Channel Flow Monitor

RPC Safety System Blue Sheet Certification Test Procedure

AIS750 Series Alarm Annunciator

SECTION FIRE ALARM SYSTEM

MSA Fixed Gas & Flame Detection for the Water & Wastewater Industries

Y7230A CO 2 Alarm System

Chlorine Gas Detection System Operation & Maintenance

ARCHITECT AND ENGINEER SPECIFICATION SECTION DETECTION AND ALARM SECURITY ACCESS AND SURVEILLANCE. DSC MAXSYS PC4020 V3.

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Control/Communicator Installation Manual

Always on the Lookout Perfect Protection against Burglary

Transcription:

QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER

QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER Centralizes Monitoring and Alarming for Gas Transmitters and Fire Detectors. The QuadScan II receiver offers an abundance of built-in, flexible features that make it the ideal receiver to economically centralize display and alarming for up to four gas transmitters, fire detectors, or other 4-20mA instruments. QuadScan II s in-the-field Channel Expansion feature allows users to initially purchase only the channels they need. Unused channels can then be easily activated with the purchase of a passcode. Housed in a NEMA-4X wallmount enclosure, the QuadScan II receiver provides power to 2-, 3-, or 4-wire transmitters and is available with an uninterruptible, battery-backed power supply to ensure constant operation during power outages. The highly visible interface includes a backlit LCD and bright LEDs that display each channel s concentration and alarm status while the built-in, 85 decibel horn provides audible notification to personnel of alarm conditions. The LCD s six alphanumeric characters can be programmed to identify each input. Standard concentration units such as PPM, PPB, or % are selectable. The QuadScan II receiver provides 4-20mA outputs for retransmission to other system controllers such as a DCS or PLC. Outputs are easily field calibrated to overcome line loss. On-screen data logging. Programmable lock-out mode. Loud built-in horn. Powerful Alarm and Relay Features The QuadScan II receiver provides common low alarm, high alarm, fail, and horn relay outputs. The alarm relays can be programmed to operate with time delay, as failsafe/non-failsafe, and automatic/manual reset.a front panel horn silence button enables user to deactivate the horn relay during alarm conditions, while the reset button deactivates latching alarms when alarm conditions have ended. For additional relay options, the QuadScan II receiver offers powerful relay programming features through a separate external relay module with a built-in power supply that provides eight individual 5 amp relays.

QUADSCAN II RECEIVER DISPLAY Each input channel is simultaneously displayed on a large, Individual or simultaneous display of each channel's output. back lit LCD. Programmable six character channel "tags" make for easy Identification of the input. Plug-in terminal connection for easy wiring. Features of the QuadScan II Receiver Accepts input from any 4-20mA transmitter. Individual or simultaneous display of each channel s output. Individual Inhibit/Fail, Warn, and Alarm LEDs. Common 5A SPDT relays for Fail, Warn, Alarm, and Horn. Programmable time delay, failsafe/non-failsafe, and manual/automatic reset. Optional relay module for up to 8 relays. Programmable and assignable to provide: - relay activation for each channel - voting logic - zoning logic 0/4-20mA output for each channel. Universal 90 to 280VAC power supply. Remote relay reset. Programmable Lock-Out mode. Built-in horn. Optional 24VDC battery back-up.

Intelligent Control with the QuadScan II Receiver The QuadScan II receiver brings intelligent control to a wide range of applications. Package any of the Scott gas or flame detectors into a powerful, small-scale detection system for your facility. Applications for the QuadScan II Receiver Pumpstation Monitoring/Sewage Treatment Facilities Hydrogen sulfide, oxygen deficiency and combustible gas transmitters combine to protect facility and personnel. Gas Cylinder Storage Areas For protection against a variety of potential gas leaks in multiple locations. Flame Detection and Fire Suppression Systems Use FlameVision gas detectors and the QuadScan II receiver s voting and zoning logic to detect and suppress fire hazards. Oil and Gas Refineries Infrared and electrochemical based detectors provide the detection capabilities for gases typically found in or around refineries Chemical Industries From textiles to pharmaceutical applications, the QuadScan II receiver and other Scott instruments and gas transmitters are used for the detection of a complete spectrum of airborne hazards. Power, Metal, and Coal Production Detect the presence of carbon monoxide, hydrocarbons (%LEL), hydrogen, and hydrogen sulfide. Parking Garages Multiple carbon monoxide and/or nitrous oxide detectors provide protection from hazardous build-ups of gases from automobiles and generators. Food and Beverage From breweries to juice production facilities, Scott instruments protect facility and personnel from carbon dioxide, carbon monoxide, oxygen deficiency, and more. Semiconductor Facilities Detect hydrogen or 40+ toxic gases such as arsine, boron trifluoride, chlorine, and much more.

Zoning and Voting Logic The QuadScan II receiver and its optional relay module bring the power of zoning and voting logic to your relays. Users determine how and when a relay or group of relays should operate through the easy-to-use interface. Voting Logic Provides extra protection against false alarms while permitting two or more transmitters to determine the presence of a hazard. In the example above, Flame Detectors #1 and #2 must both agree that a fire is present before initiating a flame suppression system. A single unit in alarm will activate audible and visual alarms alerting personnel of a potential fire. Zone Logic Permits operators to define (relay) zones for the operation of auxiliary devices. In the example above, Gas Detector #2 has detected a gas release in Room 2, relays have been zoned so that both Horns #1 and #2 activate, however, only Strobe #2 is activated for visual confirmation of which area the release has taken place. Time Delay On/Hold Gives added flexibility to the operation of auxiliary devices by permitting users to determine the amount of time a relay will either take to become active or how long it will continue to be active after a detection condition has occurred. In the example above, the relay operating the ventilation system has been selected to remain activated for 15 minutes to ensure the area has been cleared of the hazard. The gas detectors have been programmed with five second time delay to prevent nuisance alarms.

SPECIFICATIONS/INSTALLATION QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER GENERAL Enclosure.................NEMA-4X Wall Mount Temperature Range........-14 F to 122 F (-25 C to 50 C) Sensor....................Depends on gas type. Weight...................4 lbs. (1.8Kg) Optional Relay Enclosure....1 lb. (.5Kg) Horn.....................Integral - 85dB @ 3 ft. Power....................90 to 280VAC 50/60Hz or 24VDC..........................400mA max [without transmitters] User Interface.............Non-intrusive via magnet Display...................4 line/16 digit per line backlit.........................lcd for individual or simultaneous.........................display of each channel output..........................individual (per channel) LED.........................indication for Fail, Low Alarm,.........................High Alarm, and Inhibit Repeatability..............± 0.5% full scale Accuracy.................± 1% full scale Common Relays...........Low alarm, high alarm, fail and horn. APPROVALS SPDT rated 5A@250VDC Warranty.................1 year Individual Relays Battery Backup (optional).................total of eight programmable relays Enclosure (optional)........7.5 in.(d) x 12 in.(w) x 12 in.(h).........................(6) SPDT 5A@30VDC/277VAC.........................(2) DPDT 5A@ 30VDC/ 277VAC.........................Relays are installed in a separate............................nema-4x wallmount enclosure and must............................be mounted within 50 ft. of the 7400 monitor. Monroe Corporate Center P.O. Box 569 Monroe, NC 28111 Telephone: 800.247.7257 Facsimile: 704.291.8330 www.scotthealthsafety.com sh-sale@tycoint.com H/S 6724 5/08 ISO 9001 Registered. All rights reserved.