Eurovent Certification



Similar documents
Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice

HVAC Systems: Overview

The natural ombination

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction

Knowledge for optimal efficiency

Tim Facius Baltimore Aircoil

Optimization of Water - Cooled Chiller Cooling Tower Combinations

DAikin Altherma low temperature heat pump. end user leaflet

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

Elements of Energy Efficiency in Data Centre Cooling Architecture

Chapter 3.4: HVAC & Refrigeration System

Creating Efficient HVAC Systems

Cooling kw Heating kw

3/29/2012 INTRODUCTION HVAC BASICS

Air Conditioners Technical Data

APPLICATIONS AND DEFINITIONS

Building Energy Systems. - HVAC: Heating, Distribution -

Small-Scale Solar Heating and Cooling Systems

Drives and motors. A guide to using variable-speed drives and motors in retail environments

Air-Conditioning Buying Guide

State of the Art Energy Efficient Data Centre Air Conditioning

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

HIGH PERFORMANCE CHILLED WATER SYSTEMS. EarthWise HVAC. EarthWise HVAC High Performance CHW Plants

2015 C&I HVAC RETROFIT APPLICATION FOR PRESCRIPTIVE REBATES

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology

Air Conditioners Technical Data

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

HVAC Processes. Lecture 7

Todd M. Rossi, Ph.D. President

Poor Performing AC? High Electric Bills? High Humidity?

Company Presentation

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Heating & Cooling Efficiency

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Commissioning - Construction Documents (Page 1 of 6)

Defining Quality. Building Comfort. Precision. Air Conditioning

Residential Air Conditioning. Program Standards

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates

EarthCents (DSM) Program Summary

Quality approaches for residential ventilation systems in different countries and applicability in the Belgian Context

Heating, Ventilation & Air Conditioning Equipment

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

your comfort. our world. R22 replacement A complete solution for R22 Sky Air systems

Glossary of Heating, Ventilation and Air Conditioning Terms

Moisture Control. It s The Dew Point. Stupid! Its not the humidity.

Inverter technology. bulletin

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

EcoCooler New possibilities with Sales international. New! chilled air central cooling. Please contact the agent for your country or our head office:

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air. Trevor Wende Vice President, Marketing Advantix Systems, Inc.

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

WORKING DOCUMENT ON. Possible requirements for air heating products, cooling products and high temperature process chillers TRANSITIONAL METHODS

Information Guide Domestic Air Source Heat Pumps

COMMERCIAL HEATING VENTILATION & AIR CONDITIONING (HVAC)

Preliminary Final Proposal

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air

How To Design A Building In New Delhi

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

Process and Impact Evaluation of Roseville Electric s Residential New Construction, HVAC Retrofit and Commercial Custom Rebate Programs: FY2007/08

Nordic Heat Pump Product Guide

Residential Duct Systems for New and Retrofit Homes

INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling ,000 kw

ARP Food Industry, Portugal

Serenbe Green Geothermal Solutions with Bosch Thermotechnology

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM

Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics

Heating, Ventilation & Air Conditioning Equipment

Guidelines for inspection of air-conditioning systems Prof. Dr. Ing. Iolanda Colda UTCB

Achieving ENERGY EFFICIENCY with Standard Air-Conditioning Units. Mike West, PhD, PE Advantek Consulting, Inc

Climate solutions. evaporative cooling, adiabatic humidification and programmable controllers. energy saving solutions for data centers. carel.

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

Year project completed or estimated year of completion: October 2014

Energy Efficiency. Energy Efficient Home Cooling:

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Energy Efficient HVAC-system and Building Design

New energy evaluating methodology of Air conditioner and Heat pump

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

Rittal White Paper 508: Economized Data Center Cooling Defining Methods & Implementation Practices By: Daniel Kennedy

Modular Data Center Cooling. Ultra High Efficiency. Oasis Optimum DCIE

Top 10 Energy Efficiency Opportunities

your comfort. our world. Daikin Aftercare Service For total peace of mind

BEC 2012 Vs BEC Summary of Major Amendments

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0

Lower Energy Costs with Rooftop Air-Conditioning Package Units

Heat Pumps The Future of Heating in the UK?

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

Energy efficient room air conditioners best available technology (BAT)

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Wet Bulb Temperature and Its Impact on Building Performance

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Transcription:

Eurovent Certification Performance Testing and Certification Dedicated Outdoor Air Systems AHU s & Cooling Towers REHVA Seminar ACREX 7 th March 2013 Ian Butler ECC Audit Manager & Key Speaker

2/30 First to THANK ALL the drivers for getting me HERE!

3/30 Quite a big light bulb from the sky

4/30 This is not one countries problem BUT every countries problems! Where is the power coming from? Is it sustainable in what we have & are doing TODAY! Renewable Energy: Is this the only answer? Can 3 rd Party Certification help?

5/30 Look Back in History

6/30 March 2013 Can you TRUST this Products Performance? I am sure it has not been CERTIFIED!

Introduction and Plan 7/30 March 2013 Introduction Eurovent Certification Company (ECC) 18 Certification programmes, constant evolution 14 independant laboratories, recognized accreditations Process map Overview: AHU & Cooling Tower Programme s Summary & Formula for Success. Publication of data

ECC Product Certification in Detail REHVA Special Addition Journal 8/30 March 2013 http://www.rehva.eu/en/rehva-european-hvac-journal

9/30 March 2013 18 certification programmes + including VRF (publication mid-2013) (3) Air conditioners Close control AC Fan coil units Air filters Chilled beams Refrigerated display cabinets Heat exchangers Chillers & Heat pumps Air handling units Rooftops (2) Heat recovery systems Cooling towers Drift eliminators Variable refrigerant flow

10/30 March 2013 Eurovent Certification Company Much more : Committees and Commissions Certification Programmes cohabit with market expectations and legislation through Europe Continuous change progression through 12 Compliance Committees Committees made up of representatives from manufacturers, be they small or big, covering all Europe 150 people working together makes progress smooth and profitable to the whole HVAC & R industry and to its end-users Harmonisation and Integrity in Commission with associations of contractors, laboratories and end-users

11/30 March 2013 14 Independent Laboratories & testing agencies, through Europe (and more..) accredited ISO 17025 Madrid Spain CETIAT Lyon France CTI Houston USA DMT Essen Germany DTI Copenhagen Danemark HOCHSHULE Luzern Switzerland IMQ Amaro Italy MC HALE Washington USA TNO Apeldoorn Holland SP Boras Sweden TÜV-NORD Essen Germany TÜV-SÜD Munich Germany VTT Espoo Finland WSP Stuttgart Germany ECC is accredited according to EN45011:1998 equivalent ISO 17065:2012)

12/30 March 2013 Certification How does it work? Declaration lists Product ranges (and models) + Technical characteristics & Performances or Selection software Selection on-site & visit of the Production place After study of the list Selection Random selection of models No. of tests based on lifetime of models or Selection software Performance data registered from Software outputs Delivery, verification of testing object Testing in an independent laboratory Comparison declared vs. measured data If necessary: correction of catalogues or software File rejected Review, Approval, certificate and Publication of data www.eurovent-certification.com & www.certiflash.com

Independent Third Party Control in Collaboration with ECC Participants ASSURANCE THAT RULES ARE ADHERED TO! 29

CAR EXAMPLE: (Close the loop during factory audit for AHU Model Box standard manufacture) Standard Certified UNIT from Software & Factory Production You Can TRUST Special UNIT just for your test Mr Customer! NO Control

ECC website QUICK SEARCH DIFFERENT WAYS OF ACCESSING DATA

Certiflash TM - pop-up from search engines - on manufacturer websites - an app Ljgmoeigh nvoiuhva Vojziuvnû(nûnvav, V;*»p (inv,*ât,*^v Nfmehfmoifh Ahoghamo»igh Manufacturer Ljgmoeigh nvoiuhva Vojziuvnû(nûnvav, Vojzuv nûnvav,

Overview of energy labels & performances for HVAC products Res. 17/30 2012 Product AC<12kW Vent. units 2002 2013 2015? MEPS Energy performances 2013 1995 2015? 2015? Description (S)EER, (S)COP SEC Boilers/HP 2015 2015 1995 (HP) η s Chillers/HP 2004 2015? 1995 (S)EER, (S)COP, ESEER Non Res. Fans VRF Rooftops AC>12kW AHU Fan Coils? 2010? 2008 2011 2013 2015? 2015? 2015? 2015? 2013 2007 1995 2007 1995 η (S)EER, (S)COP (S)EER, (S)COP (S)EER, (S)COP f(v,η, p,f) FCEER, FCCOP Air Filters 2012 2007 An. En. Cons HEx 2005 2001 R

18/30 March 2013 Air handling units Key facts 6 classes from A to <E: complex interrelationships to evaluate the energy efficiency of AHU, can even depend on climate conditions One letter to represent balanced effects of: Air velocity in the fan section (v) Heat recovery efficiency (η) and pressure drop (Δp) Fan efficiency (f) 3 subgroup of products: Design outdoor temperature < 9 C (HRS will significantly save energy) Design outdoor T > 9 C : N Single supply / extract units : h Timeframe 2 nd draft commission working document expected mid-march 2013 Units for full or partial All Units outdoor air at design winter CLASS temperature 9 C Absorbed power Velocity Heat recovery system factor v class [m/s] η class [%] Δp class [Pa] f class Pref [-] A / AN / Ah 1.8 75 280 0.9 B / BN / Bh 2.0 67 230 0.95 C / CN / Ch 2.2 57 170 1.0 D / DN / Dh 2.5 47 125 1.06 E / EN / Eh 2.8 37 100 1.12 <E / <EN /<Eh No calculation required No requirement

19/30 March 2013 1200 1000 800 ECC energy label for Fan coil units Others Variable speed fan 600 400 200 0 G F E D C B A Classes A and B only achieved by variable speed fan units Technology & Innovation driving Efficiency

20/30 March 2013 ECC energy label for Fan coil units Timeframe Available since 2011 First energy label for FCU in the world! Key facts Weighted average of performance of low, medium and high speeds FCEER 5% Pc 5% Pe( c) high high 30% Pc med 30% Pe( c) med 65% Pc low 65% Pe( c) low 5% Ph FCCOP 5% Pe( h) high high 25% Ph Consider both sensible and latent capacities med 25% Pe( h) med 70% Ph low 70% Pe( h) low

ECC Collaboration & Incentives Eurovent Certification & Cooling Technology Institute For Cooling Tower Certification (Joint Certification Programme) NEW PROGRAMME Eurovent Certification Liquid Chiller Package / Heat Pump & NFCAP French Heat Pump Certification, Recognition of Products that Meet Specified Quality Requirements i.e. COP with Min Thresholds Eurovent Certification Members AHU s & VLA (Netherlands) Government Capital Rebate programme (For ECC Air Handling Members with Certified A Class products) Eurovent Certification Members Remote Refrigeration Display Cabinet s & Spanish Government Government incentives for High Efficiency Refrigeration Display Cabinets (Energy Class A & B only)

Cooling Tower Certification Started Feb,2012 22/30 March 2013 3 rd Party Performance Labels you can trust

23/30 March 2013 Cooling Tower Certification for Open Circuit & soon to announce inclusion of Closed Circuit The importance of air conditioning and industrial cooling is constantly increasing in modern architecture and industrial process cooling. The human perception of comfort and the new challenges to reduce the electrical power consumption and CO2 footprint have designers striving for optimal system performances with the highest possible efficiencies. Reliable thermal performances are crucial to ensure these best efficiencies which are typical for cooling circuits driven by evaporative cooling equipment. Eurovent Certification Company guarantees the consistency of thermal testing and manufacturing of European and non- European companies that subscribe to the program.

24/30 March 2013 Summary Key benefits in one glance Easy product selection in HVAC-R Direct comparison of competitive products Good for customer, good for the planet New installations as well as retrofitting Less energy consumption as the unit runs as expected to achieve the required performance reduced product climate and environmental impact as well as electricity costs Possible Incentives for more energy savings? In all cases, the best practice: Good design (avoid oversizing) ask for third party certified performances Good energy efficiency ask for third party certified best classes

Formula For Success: Certified efficient products, Optimized system designs, & Professional installations Some key issues: Air Re-circulation Noise Amplification Control Strategy Poor Installation Regular Maintenance Cleaning!

Stand No. C41, Area 18 Thank you for your attention