Product and functional description



Similar documents
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Transmitter Actuator 230V wave UP 560. Operation

Product and Application Description

DALI RC BASIC SO. Control unit Operating instructions

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

KNX Interface. User Manual PM00A00IRI

How To Use A Power Supply On A Powerline 2.2 (Ai)

Inwall 4 Input / 4 Output Module

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Emergency lighting units EM powerled

Operating instructions IV / 2007

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

ABB i-bus KNX DALI-Gateway DG/S 8.1

Push button 3gang standard flush-mounted xx

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Digital input modules

Tebis KNX Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 131

Light scene push button 8gang comfort flush-mounted xx

HERZ-Thermal Actuators

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M ES/M , ES/M

13 SERIES. Electronic step relays A

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ABB i-bus KNX SA/S Switch Actuators Product Manual

Actuator-Sensor-Interface

Drayton Digistat +2RF/+3RF

E-STOP relays, safety gate monitors

Operating instructions II / 2004

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

Quick Connect. quick - simple - efficient.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

MCR1900 Media Converter 19-Slot Chassis

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

ABB i-bus KNX Fan Coil Controller FC/S 1.1

is then retained absolutely without interruption.

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

5SV Residual Current Protective Devices

Modular I/O System Analog and Digital Interface Modules

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

Safety technique. Emergency stop module BO 5988 safemaster

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

MINI MCR-SL-R-UI(-SP)

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Installation Instructions. Thermo Call TC3

48 SERIES Relay interface modules 10 A

ACS-30-EU-EMDR-10-MOD

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

PCS0100en Persy Control Services B.V. Netherlands

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

KNX R. Rain Sensor. Installation and Adjustment

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

PHOENIX CONTACT Features

MasterINTERFACE 39 Series - Relay interface modules

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

HCR3.2/.. Chipcard reader HOTEL SOLUTION

TMS TANK MANAGEMENT SYSTEM

Redundancy Module QUINT-DIODE/40

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S Intelligent Installation Systems ABB

Tebis application software

Installation Instructions. ThermoCall TC4. Entry/Advanced

Operating instructions

PNOZsigma - Base units

Inwall Room Temperature Unit

15 Series - Electronic step relay and dimmer. Features SERIE

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

Type: DILM32 10(24V50HZ) Article No.:

ADM1TE 5/30A DIN rail single phase two wire energy meter

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Building Service Management System instabus EIB

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

PHOENIX CONTACT - 01/2007

Type: DILM50(230V50HZ,240V60HZ) Article No.:

LED Driver Compact dimming. Udriver LCAI 35W 350mA 900mA ECO C ECO series

2013 Wireless Video Intercom INSTALLATION GUIDE

Transcription:

Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected to. It is not allowed to connect DALI sensors to the DALI interface of the N 141/02. DALI (Digital Addressable Lighting Interface) is a bidirectional communications interface in accordance with IEC 60929, whose specification has been defined by manufacturers of electronic ballasts. It not only enables the receipt of e.g. switching and dimming commands but also the sending of status information such as the failure of a lamp or the report of a detected error in the electronic ballast. According to IEC 60929 up to 64 DALI devices can be connected to a DALI line and can each be assigned an individual device address. The enables communicating with up to 64 DALI devices including detection and transmission of DALI status and failure information via KNX. DALI actuators can be switched and dimmed either individually or in groups. If a DALI actuator is assigned to one of the 16 groups it cannot be controlled individually anymore. An individual name, a group, parameters and scenes (refer to the application program description) are assigned to the individual DALI electronic ballasts during commissioning with the ETS (Engineering Tool Software). The power supply unit integrated in the N 141/02 supplies the gateway electronics and generates the DALI voltage. Additionally, it enables the operation of the gateway and a direct switching of all lamps controlled over its DALI interface even if the N 141/02 has not yet been commissioned with the ETS or if the communication via the KNX bus has been interrupted. For this purpose, the N 141/02 has a pushbutton located bottom left on its front plate for switchingon the Direct mode as well as for switching back to the Bus mode. When this pushbutton has been pressed for the first time the yellow light emitting diode (LED) lights up permanently to indicate direct mode. Then all lamps controlled via DALI can be switched On or Off all together via the relevant two pushbuttons on the front plate of the gateway: pressing briefly the upper pushbutton switches the channel On while pressing briefly the lower push button switches the channel Off. A red LED integrated in the upper push button is used to indicate the On state of the lamps by a continuous light and to indicate a DALI cable error by flashing. If the direct mode button is pressed for a second time, the yellow LED to indicate direct mode is extinguished and the N 141/02 is switched to Bus mode. The can be used to control DALI actuators in emergency luminaires. Selfcontained emergency luminaires containing two DALI devices (ballast and an inverter, each with a DALI interface) only up to 32 selfcontained emergency luminaires may be connected to an N 141/02. The gateway automatically detects if a selfcontained emergency luminaire contains two or only one DALI actuators. Selfcontained emergency luminaires with two DALI interfaces and normal luminaires with only one DALI interface may be connected to the N 141/02, but the total number of 64 DALI devices may not be exceeded. Selftest of the inverters of selfcontained emergency luminaires can be started and the test result reported via the bus. The type of test (function test, short duration test or long duration test) that has to be started or has started can be commanded or queried. A test result will be reported automatically at the end of a test or can be queried. All luminaires controlled by a N 141/02 can be dimmed to the set Dimming value on emergency even when they are not effected by any mains or DALI power failure. By this all luminaires may be dimmed to the same brightness level as all selfcontained emergency luminaires. During Emergency Operation all luminaires will not respond to any on/off or dim commands and cannot be commissioned. Application program 07 B0 KNX / DALI Gateway 981C0C Siemens AG N 141/02, 6 pages Technical manual Low Voltage Distribution Siemens AG 2010 Update: http://www.siemens.com/gamma 2.5.2.3/1

Versorgung supply AC 230 V Busankoppler bus coupling unit Versorgung supply AC 230 V DALI GAMMA instabus Connection example instabus EIB instabus / DALI Gateway N 141 + PE N L AC 230V L PE N + N PE L DALI EVG DALI ECG 1 DALI Leuchtstofflampe fluorescent lamp + N PE L DALI EVG DALI ECG 64 DALI Leuchtstofflampe fluorescent lamp Installation notes The device can be used for permanent installation in dry, interior rooms and for insertion in distribution boards or miniature housings. V WARNING The device must be mounted and commissioned by an authorised electrician. Unoccupied sections of DIN rail with data rail inserted must be protected with the cover 5WG1 1928AA01. When connecting the device, it should be ensured that the device can be isolated. The device may not be opened. When planning and installing electrical installations, the relevant guidelines, regulations and specifications of the respective country must be observed. Technical data Power supply KNX Bus voltage: carried out via the bus line KNX bus current: 5 ma (only half a standard bus load! ) Electronics and DALI output: integrated power supply for AC/DC 110240 V, 50400 Hz power consumption: max. 7 W Inputs/outputs Mains connection: 3pole (PE, N, L) DALI output (according to IEC 60929): max. 64 DALI devices with > 8 kohm input impedance DALI bus voltage: approx. DC 19 V, floating, shortcircuitproof Operating elements 1 learning push button: for toggling between normal mode / addressing mode 1 push button: for toggling between bus mode / direct mode 2 push buttons: for switching all electronic ballasts ON / OFF Display elements 1 red LED: for checking the bus voltage and for displaying normal mode / addressing mode 1 green LED: for displaying the 230 V operating voltage 1 yellow LED: for displaying direct mode / bus mode 1 red LED per push button: for ON / OFF status indication (only in direct mode) and failure indication by blinking with 1 Hz (communication or lamp fairlure) Connections Plugin terminals for mains voltage and DALI output, insulation strip length 10... 11 mm The following conductor crosssections are permitted: 0.5... 3.3 mm 2 (AWG 12) singlecore 0.5... 3.3 mm 2 (AWG 12) stranded multicore 0.5... 3.3 mm² (AWG 12) finely stranded, untreated 0.5... 1.5 mm 2 finely stranded, with connector sleeve The supply cable to the N 141 must be fused with a circuitbreaker of characteristic B or C for a max. nominal current of 6 A! KNX Bus line: Pressure contacts on data rail and bus terminal Technical manual N 141/02, 6 pages Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2010 Low Voltage Distribution 2.5.2.3/2

Mechanical data Housing: plastic Dimensions: DIN rail mounted device in Nsystem dimensions, width: 4 module units (1 module unit = 18 mm) Weight: approx. 150 g Fire load: approx. 3400 kj Installation: Snapon mounting on DIN rail EN 60715TH357.50 Electrical safety Degree of pollution (according to IEC 606641): 2 Protection type (in accordance with EN 60529): IP 20 Overvoltage category (according to IEC 606641): III Bus: safety extralow voltage SELV DC 24 V Device complies with: EN 5009022 and EN 6066921 EMC requirements complies with EN 5009022 Environmental conditions Climatic withstand capability: EN 5009022 Ambient operating temperature: 5... + 45 C Storage temperature: 25... + 70 C Relative humidity (not condensing): 5 % to 93 % Reliability Failure rate: 465 fit at 40 C Markings KNX EIB CE mark In accordance with the EMC guideline (residential and functional buildings), low voltage guideline Location and function of the display and operating elements A5 A10 A9 A8 A6 A1 Figure 1: Location of the display and operating elements A1 Button for toggling between normal / addressing mode for transferring the physical address A2 LED (red) for displaying normal mode (LED off) or addressing mode (LED on); it is automatically extinguished once the physical address has been transferred A3 Plug for bus connecting terminal A4 Pushbuttons for direct operation (all lamps On / Off) A5 Red LED direct mode: status all lamps (On/Off) display DALI failure flash N times approx. 1s break flash N times N = 1: > 230V connect to DALI Input! N = 2: > shorted DALI cable! N = 3: > low DALI voltage! N = 4: > no DALI device connected! A6 Terminals for the DALI bus cable (D+, D) A7 Terminals for protective earth, neutral and phase conductor (PE, N, L) A8 LED (yellow) for displaying when direct mode = On A9 Button for toggling between bus / direct mode A10 LED (green) for displaying the operating voltage A2 A3 A4 A7 Siemens AG N 141/02, 6 pages Technical manual Low Voltage Distribution Siemens AG 2010 Update: http://www.siemens.com/gamma 2.5.2.3/3

Installation and wiring General description The DIN rail mounted device in N system dimensions (width 4 module units) can be inserted in N distribution boards, surface or flushmounted and wherever DIN rails EN 5002235 x 7.5 are available. The connection with the bus line is either carried out via a bus terminal or via the contact system to the data rail. Installing the DIN rail mounted device (Figure 2) Suspend the DIN rail mounted device (B1) on the DIN rail (B2) and Rotate the DIN rail mounted device backwards until the slide switch audibly clicks into position. Dismantling the DIN rail mounted device (Diagram 2) Remove all the connected cables, press the slide switch (C3) downwards with a screwdriver and remove the DIN rail mounted device (C1) from the DIN rail (C2) with a swivel action. Connecting the bus cable (Figure 3) The bus terminal (D2) is suitable for singlecore conductors with 0.6... 0.8 mm Ø. Strip approx. 5 mm of insulation from the conductor (D2.4) and plug in the terminal (D2) (red=+, black=). Disconnecting the bus cable (Figure 3) Remove the bus terminal (D2) and the conductor (D2.4) out of the bus cable by rotating it backwards and forwards. D2 D1 D2.1 D2.2 D2 D2.3 D2 D2.4 5 mm B2 C2 D2 B1 C1 Figure 2: Installing / dismantling the DIN rail mounted device Removing the bus terminal (Figure 3) The bus terminal is located on the top of the device (D1) The bus terminal (D2) consists of two sections (D2.1, D2.2), each with four terminal contacts. Care should be taken not to damage the two test sockets (D2.3), either by accidentally connecting them to the bus conductor or with the screwdriver (when trying to remove the bus terminal). Carefully insert the screwdriver in the wire entry slot underneath the bus terminal (D2) and pull the bus terminal forwards out of the device (D1). Note: Care should be taken as there is a risk of shorting the device! Connecting the bus terminal (Figure 3) Place the bus terminal in the guide slot and press the bus terminal (D2) backwards until it reaches the stop. C3 D2.4 Figure 3: Connecting and disconnecting the cable Connecting mains voltage and DALI bus cables The connections are designed with plugin technology. Strip approx. 1011 mm of insulation from the conductors and slide in the respective terminal. Crosssections: The following conductor crosssections are permitted: 0.5... 3.3 mm2 (AWG 12) singlecore 0.5... 3.3 mm2 (AWG 12) stranded multicore 0.5... 3.3 mm² (AWG 12) finely stranded, untreated 0.5... 1.5 mm2 finely stranded, with connector sleeve The mains connection must be fused with a circuitbreaker of characteristic B or C with a max. nominal current of 6 A! Mounting the insulating cap If the device should be mounted on a DIN rail without a data rail, the contact system must be covered with the supplied insulating cap. Removing the locating clamp (Figure 4) The locating clamp (E3) encloses the contact system (E2) on the rear of the DIN rail mounted device (E1). Insert the screwdriver between the DIN rail mounted device (E1) and the locating clamp (E3) and remove the clamp. Technical manual N 141/02, 6 pages Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2010 Low Voltage Distribution 2.5.2.3/4

Clipping on the insulating cap: (Figure 4) Place the insulating cap (E4) on the contact system and press so that it snaps in place. E3 E1 E2 E2 E4 E1 General notes The operating instructions must be handed over to the client. A faulty device shall be sent with a Return Good Note for Service provided by the appropriate Siemens sales office to the following address: SIEMENS AG, Siemensstr. 10, D93055 Regensburg If you have further questions concerning the product please contact our technical support. +49 (911) 8957222 +49 (911) 8957223 support.automation@siemens.com www.siemens.de/automation/supportrequest Figure 4: Covering the contact system Dimension drawing Dimensions in mm 90 45 b b = 4 module units 44 55 (1 module unit = 18 mm) Siemens AG N 141/02, 6 pages Technical manual Low Voltage Distribution Siemens AG 2010 Update: http://www.siemens.com/gamma 2.5.2.3/5

Space for notes Technical manual N 141/02, 6 pages Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2010 Low Voltage Distribution 2.5.2.3/6