Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.



Similar documents
Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

RY2 miniature industrial relays

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Manual motor starter MS116

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Switching Devices Contactors and Contactor Assemblies Special Applications

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

INDICE MINI-CONTATTORI / CONTENTS MINI-CONTACTORS. Criteri di scelta pag Product selection. Caratteristiche tecniche pag Tecnical data

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Type: DILM32 10(24V50HZ) Article No.:

49 Series - Relay interface modules A. Features

48 SERIES Relay interface modules 10 A

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Safety automation solutions

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Three-phase monitoring relay CM-PFE

40 Series - Miniature PCB/Plug-in relays A. Features

Thermistor motor protection

Technicaldata General

60 Series - General purpose relays 6-10 A. Features

Technical catalogue. Modular DIN rail components Installation contactors

Series 8146/5-V37 and Series 8150/5-V37

RM4TG20 three-phase network control relay RM4-T - range V

Type: DILM9 10(24VDC) Article No.:

Cable Plug acc. to DIN EN , Form A

Catalog. Modular DIN rail components Installation contactors

D-Line Contactors, Overload Relays and Accessories

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

38 Series - Relay interface modules A

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Manual Motor Starter MS 116 up to 16 A Technical Data

R.C.C.B. s two-pole LEXIC

Relés e Contatores de Estado Sólido SIRIUS

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

38 Series - Relay interface modules A

Pluggable interface relays CR-P Pcb relays

MasterINTERFACE 39 Series - Relay interface modules

Technical Catalogue. Mini Contactors. Type B 6, B 7

Safety detection solutions

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

E-STOP relays, safety gate monitors

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Description Part-No. Type PU. Nominal voltage DC12V Relais-SNR 12V 1W 20 DC 24 V Relais-SNR 24V 1W 20

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Model Number Structure

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Emergency lighting units EM powerled

Catalog January. Heavy industrial power applications Motor contactors and starters

Model Number Structure

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

MasterINTERFACE 39 Series - Relay interface modules

Plug and Socket Devices CES 63 A Series 8579

5SV Residual Current Protective Devices

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

General Purpose Relays Accessories. Accessories Miniature Relay PT

BETA Protecting SITOR Semiconductor Fuses

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

Fieldbus slave modules with I/Os, DIO

NX safety stand-alone

Preventa Machine Safety Products

Inductive sensor NI10-M18-Y1X-H1141

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

HYUNDAI U-Series Magnetic Contactor Overload Relay

Plug-in relays Mini ISO relays

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Actuator-Sensor-Interface

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Catalog EN. Content Transformers for industrial applications

TISP4600F3, TISP4700F3 OBSOLETE

PSR The compact range Description

CompactLogix Power Supplies Specifications

Power Supplies 3. SDN-P DIN Rail Series

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

MINI CONTATTORI / MINI CONTACTORS

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Product and functional description

PLC-RS /21. PLC INTERFACE With PDT Relay, Universal Version. INTERFACE Data Sheet _en_02. 1 Description

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Transcription:

Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9

Micro Contactor Relays 4pole C Operated RatingsTherm. Contacts 2) Coil voltage ) Distinc. dditional 50/60Hz Number Contact 2 50Hz/60Hz C5 Rated Current 400 I th acc. to Blocks Pack Weight NO NC EN500 pcs. kg/pc. 4pole, With Screw Terminals 3,5 5 4 40E K004D40... 0 3,5 5 3 3E K004D3... 0 3,5 5 2 2 22E K004D22... 0 K004D40 K004D3 K004D22 ) Other coil voltages on request. 2) Contacts suitable for electronic circuits, according to EN94754 for rated voltage DC (test ratings 7 DC, 5m). Positively guided contacts. 0

Micro Contactors C Operated Power Ratings C2, C3 C 380 400 660 45 690 Rated Current ux. Contacts2) Builtin dditional 440 NO NC Coil voltage ) 50/60Hz 2 50Hz/60Hz Pack pcs. W Weight kg/pc. 3pole, With Screw Terminals K005D0... 0 K005D0... 0 K005D0040... 0 4pole, With Screw Terminals K005D0 K005D0 K005D0040 ) Other coil voltages see page. 2) Contacts suitable for electronic circuits, according to EN94754 for rated voltage DC (test ratings 7 DC, 5m). Positively guided contacts.

Micro Contactors C Operated Power Ratings Rated Current C2, C3 C 380 400 660 45 690 690 ux. Contacts2) Built dditional in NO NC Coil voltage ) 50/60Hz 2 50Hz/60Hz Pack pcs. W Weight kg/pc. 3pole, with Solder Pins Ø,5 for Printed Circuit pplications xxx3) K005L0... 0 xxx3) K005L0... 0 0 4pole, with Solder Pins Ø,5 for Printed Circuit pplications xxx3) K005L0 K005L0040... K005L0 K005L0040 Coil voltages for C operated contactors Suffix to contactor type e.g. K09D0 48 oltage Marking Rated Control oltage Us at the coil for for 50Hz 60Hz range for 50Hz min. max. 48 48 90 95 00 00 9500 00 00 050 05 05 0 80 050 05 50 05 22 38,5 48 for 60Hz min. max. Suffix to contactor type e.g. K09D0 oltage Marking Rated Control oltage Us at the coil for for 50Hz 60Hz range for 50Hz min. max. 50 48 52 20 20525 20 90 95 00 00 00 05 00 05 0 05 0 5 0 0 05 0 85 0 5 5 0 0 5 20 2 250 95 205 20 205 25 0 250 0 250 260 Standard voltages in bold type letters Operating range of magnetcoils: 0,85 x Us (min. value of rated control voltage) up to, x Us (max. value of rated control voltage) Coil not exchangeable ) Other coil voltages see page. 2) Contacts suitable for electronic circuits, according to EN94754 for rated voltage DC (test ratings 7 DC, 5m). Positively guided contacts. 3) Data on request. for 60Hz min. max.

Micro Reversing Contactors, Mechanical Interlocked C Operated Power Ratings Rated Current C2, C3 380 400 660 45 690 C ux. Contacts2) Builtin dditional on left on right hand side hand side Contactor Contactor 690 NO NC K K2 Coil voltage ) 50/60Hz 2 50Hz/60Hz W Pack pcs. Weight kg/pc. 3pole, with Screw Terminals K0W05D0MC... 0,4 K0W05D0MC... 0,4 K0W05D0040MC... 0,4 4pole, with Screw Terminals 3pole, with Solder Pins Ø,5 for Printed Circuit pplications xxx3) K0W05L0MC... 0,4 xxx3) K0W05L0MC... 0,4 K0W05D0MC K0W05D0MC K0W05D0040MC ) Other coil voltages see page. 2) Contacts suitable for electronic circuits, according to EN94754 for rated voltage DC (test ratings 7 DC, 5m). Positively guided contacts. 3) Data on request. 3

Micro Contactors Data according to IEC 609474, DE 0660, EN 609474 Main Contacts K005D.. Rated insulation voltage U i C 480 ) Making capacity I eff at U e = 440 C 65 Breaking capacity I eff 400 C 50 cosϕ = 0,65 Utilization category C Switching of resistive load Rated operational current I e (=I th ) at 40 C, open Rated operational power of threephase resistive loads 4,7 5060Hz, cosj = 0 4,8 400 8,3 45 8,6 480 9,5 Rated operational current I e (=I th ) at 60 C, enclosed 8 Rated operational power of threephase resistive loads 3, 5060Hz, cosj = 0 3,3 400 5,5 45 5,7 480 6,5 Minimum crosssection of conductor at load with I e (=I th ) mm²,5 Utilization category C2 and C3 Switching of threephase motors Rated operational current I e 6,2 open and enclosed 6,2 0 5,6 380400 5 45440 5 480 5 Rated operational power of threephase motors 2,5 5060Hz 380440 480 Utilization category C4 Switching of squirrel cage motors, inching Rated operational current I e 4,9 open and enclosed 4,9 0 4, 380400 5 45440 5 480 5 Rated operational power of threephase motors 2, 5060Hz 380440 480 ) Suitable at 690 for: earthedneutral systems, overvoltage category I to III, pollution degree 3 (standardindustry): Uimp = 4k. Data for other conditions on request. 4

Micro Contactors Data according to IEC 609474, DE 0660, EN 609474 Main Contacts Utilization category DC Switching of resistive load Time constant L/R ms Rated operational current Ie K005D.. pole 60 0 3 poles in series 60 0 C C C C 40 to +60 (+90) ) 40 to +40 25 to +60 25 to +40 C 50 to +90 Utilization category DC3 and DC5 Switching of shunt motors and series motors Time constant L/R 5ms Rated operational current Ie pole 60 0 3 Pole in Serie 60 0 Maximum ambient temperature Operation open enclosed open enclosed with therminal overload relay Storage Short circuit protection for contactors without thermal overload relay Coordinationtype "" according to IEC 9474 Contact welding without hazard of persons max. fuse size gl (gg) 20 Coordinationtype 2 according to IEC 9474 Light contact welding accepted max. fuse size gl (gg) Contact welding not accepted max. fuse size gl (gg) For contactors with thermal overload relay the device with the smaller admissible backup fuse (contactor or thermal overload relay) determines the fuse size. Cable crosssections for contactors main connector solid or stranded flexible flexible with multicore cable end Cables per clamp mm² mm² mm² 0,5,5 0,5,5 0,5,5 2 WG 20 4 without load C3, Ie C4, Ie DC3, Ie /h /h /h /h 0000 600 0 600 Sx Sx 06 06 3 xxx2) 0scurrent 50 at Ie /C3 400 W 0,2 NO NC g g 2,5 2,5 solid or stranded Frequency of operation z contactors without therminal oberload relay Mechanical life C operated DC operated Short time current Power loss per pole Resistance to shock according to IEC 68227 Shock time 20ms sinewave C operated ) With reduced control voltage range 0,9 up to,0 x Us and with reduced rated current Ie /Caccording to Ie /C3. 2) Data on request. 5

Micro Contactors Data according to IEC 609475, DE 0660, EN 609475 uxiliary Contacts K004D.. K005D.. Rated insulation voltage U i C 440 ) Thermal rated current I th bis 440 mbient temperature 40 C 5 60 C 3 erlustleistung pro Pol bei I th W 0,25 Utilization category C5 Rated operational currrent I e 2 3 38045,5 440 Utilization category DC3 Rated operational current I e 60 0,5 Maximum ambient temperature Operation open C 40 bis +60 (+90) 2) enclosed C 40 bis +40 Storage C 40 bis +90 Short circuit protection shortcircuit current k, contact welding not accepted max. fuse size gl (gg) 0 For contactors with thermal overload relay the device with the smaller admissible control fuse (contactor or thermal overload relay) determines the fuse size. Power consumption of coils C operated inrush 9 sealed 4 W,8 Operation rage of coils in multiples of control voltage U s 0,85, Switching time at control voltage U s ±0% C operated make time ms 3 8 release time ms 5 0 arc duration ms 0 5 DC operated make time ms release time ms arc duration ms Cablecrosssection all connectors solid mm 2 0,5,5 flexible mm 2 0,5,5 flexible with multicore cable end mm 2 0,5,5 Clamps per pole 2 solid or stranded WG 20 4 3) 4) ) Suitable at 690 for: earthedneutral systems, overvoltage category I to III, pollution degree 3 (standardindustry): Uimp = 4k. Data for other conditions on request. 2) With reduced control voltage range 0,9 up to,0 x U s and with reduced thermal rated current I th to I e /C5. 3) Summary switching time = release time + arc duration. 4) Release time of NC make time of NO increase when suppressor units for voltage peak protection are used (aristor, RCunits, Diode units). 5) Data on request. 6

Micro Contactors for North merica Data according to UL508 Main Contacts (culus) Rated operational current "General Use" 5 00 208 2 277 440480 550600 ½ ½ 00 208 2 ½6 ½ ¾ Rated operational power of three motors at 60Hz (3ph) Rated operational power of C motors at 60Hz (ph) K005D.. K0W05D0.. K004D.. Fuse / Shortcircuit current /k 30/5 Rated voltage C 300 300 C DC B300 R300 B300 R300 uxiliary Contacts (culus) Motor Rating Pn = C4 heavy pilot duty standard pilot duty Motor Rating Pn = C3 Breaking Current Ia ( = Ie = C) Millions of Operations 7

Micro Contactors Dimensions C operated with screw terminals K004D.. K005D.. C operated with solder connections K004L.. K005L.. Reversing Contactors with screw terminals K0W05D..MC Reversing Contactors with solder connections K0W05L..MC 8