continuing professional education. As such, it construed to be an approval or endorsement by



Similar documents
Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls and Sloped Glazing Systems

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

FIELD TESTING SERVICES

Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

WATER LEAKAGE IN GLAZED CURTAIN WALL SYSTEMS:

Specifying Windows. Performance Standards

Testing Water Penetration Resistance of Window Systems Exposed to Realistic Dynamic Air Pressures

DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1

TEST REPORT. Report No.: B Rendered to: CROFT, LLC. Magnolia, Mississippi. PRODUCT TYPE: Aluminum Single Hung Window SERIES/MODEL: 95

PERFORMANCE TEST REPORT

Assessing Curtain Walls

Architectural Testing

Field Water Testing - Lessons Learned

resist water infiltration and avoid water damage to buildings.

PERFORMANCE TEST REPORT. Rendered to: TREMCO INCORPORATED. SERIES/MODEL: Proglaze ETA PRODUCT TYPE: Engineered Transition Assembly

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems

T H E A A M A C E R T I F I C A T I O N P R O G R A M

REPORT NUMBER: COQ-003 ORIGINAL ISSUE DATE: July 19, 2013

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: Atrium Companies, Inc. SERIES/MODEL: 50/305 HS PRODUCT TYPE: Vinyl Horizontal Slider

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

WATER TESTING MISCONCEPTIONS: F ENESTRATION PRODUCT CERTIFICATION AND FORENSIC INVESTIGATION OF BUILDING LEAKAGE

Installer Training and Certification Overview

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Table of Contents PART 1 WINDOW SELECTION GUIDE. Window and Door Selection Guide

Williamson and Associates, Inc. Report of Building Exterior Condition Evaluation, dated January 2 nd, (68 pages)

research highlight Water Penetration Resistance of Windows - Study of Codes, Standards,Testing, and Certification

PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM CORPORATION. SERIES/MODEL: 450 Center Glaze PRODUCT TYPE: Aluminum Curtain Wall

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: EAGLE WINDOW & DOOR COMPANY

TEST REPORT. Rendered to: INTERNATIONAL WINDOW Hayward, California. PRODUCT TYPE: Aluminum Hopper SERIES/MODEL: 7222

City of San Diego, CWP Guidelines

PERFORMANCE EVALUATION OF THE CERAMITEX RVR SYSTEM IN ACCORDANCE WITH AAMA FOR PRESSURE EQUALIZATION BEHAVIOR & WATER PENETRATION RESISTANCE

SECTION METAL WALL PANELS

Exterior Elevated Elements Inspection Guidelines

JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC ALUMINUM WINDOWS Guide Specs

Mario D. Gonçalves, Patenaude-Trempe 1 Pierre Gendron, Patenaude-Trempe 2 Tony Colantonio, PWGSC 3. Abstract

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

PERFORMANCE TEST REPORT. Rendered to: ARCHITECTURAL METAL SOLUTIONS, INC.

10DBMC International Conference On Durability of Building Materials and Components LYON [France] April 2005

TEST REPORT. Rendered to: DEXERDRY. For: Deck Weatherproofing System Installed with AZEK Deck Boards

Total Building Commissioning: Case Study of the U.S. District Courthouse in Salt Lake City, Utah, USA

BECx& Building Airtightness. Presented by: Eric Amhaus Principal

BUILDING ENVELOPE COMMISSIONING FOR THE EVERYDAY COMMISSIONING AGENT

Non Invasive Roof Leak Detection Using Infrared Thermography

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: NORSE, INC.

Preventing Ice Dams on Roofs

Window Sill Details for Effective Drainage of Water

UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

Sun Windows General Information Sun New Construction Window Installation Instructions

How To Control Water Penetration In A Window

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

WATER PENETRATION TESTING OF STUCCO ON CONCRETE MASONRY CONSTRUCTION

SECTION STANDING SEAM METAL ROOF

NAFS and The 2012 Building Code

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

Appendix B Florida Building Code Building Section Public Shelter Design Criteria

AAMA Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure

The Science of Rough Opening Preparation and Window Installation to Minimize Air Leakage

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

RDH Building Sciences Inc.

Techniques for Finding and Documenting Moisture Intrusion in Buildings with an Infrared Imager by: R.W. Olsen & Greg Stockton

Window Installation Instructions

How To Test For An Architectural Test

Impact-Resistant Windows and Sliding Glass Doors

The Florida Building Code

March 14, Installation of Bay, Bow and Garden Windows

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS WINDOWS

How To Test Water Penetration On Concrete Block And Mortar

Introduction...COMB-2 Design Considerations and Examples...COMB-3

SECTION SERIES 1500 VINYL PATIO DOORS

CH. 2 LOADS ON BUILDINGS

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

Building Code Clarifications - 7. Fire Resistance

Figure 1A. Typical brick veneer installation over wood frame construction.

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida

Windows, skylights, vents, and glazed portions of doors are critical components of a building s

Waterproofing Problems: A Simple Explanation, A Simple Solution

SECTION STANDING SEAM METAL ROOFING

The replacement or modification of existing windows shall comply with the following requirements:

StuccoSpec Moisture Testing Inspection

Simplified Steel Stair Design for Commercial and Institutional Buildings

Weather Resistive Barriers: Building Science Makes a Case for Two Layers by Dave Olson Technical Services Manager, Fortifiber Building Systems Group

Clad Direct Glaze Window Installation Instructions

TEST REPORT. Rendered to: BRISTOLITE SKYLIGHTS Santa Ana, California

I S S U E 1/2013 VOLUME 30 NUMBER 1. Water Testing: Richard P. Kadlubowski, AIA and Courtenay Bauer

AST M F /GSA TS01 T EST R EPO R T. Rendered to: UNI T E D ST A T ES A L U M INU M

AIA PRESENTATION. Standing Seam Metal Roofing Seminar SSRLU2B 1 LU/HSW Hour

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: CR LAURENCE CO., INC. SERIES/MODEL: 7500 Concealed Vent TYPE: Projecting (Awning)

Colorado State University. Durrell Center Roof Repair

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

A. Work on this project shall consist of, but is not limited to, the following:

Water Damage & Repair

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

Transcription:

This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product. Questions related to specific materials, methods, and services may be addressed at the conclusion of this presentation.

This presentation is protected by U.S. and International copyright laws. Reproduction, distribution, display and use of the presentation without written permission of the speaker is prohibited. American Architectural American Architectural Manufacturers Association 2010

Comparison of the AAMA/WDMA/CSA 101/I.S.2/A440-08 lab test (referred to as NAFS-08) to the AAMA 502 quality assurance field test and the AAMA 511 forensic evaluation Determination of appropriate water test pressures, test durations and water applications via NAFS-08, AAMA 502-08, 503-08 and 511-08 How to specify project-specific p quality assurance field testing The proper use of AAMA 511 for forensic The proper use of AAMA 511 for forensic evaluations

NAFS-08 Lab Testing Performed on prototype specimen to validate product performance ratings Intro oduc ction 502 Quality Assurance Field Testing Performed on newly installed products to verify installed performance of the product and the installation 511 Forensic Testing Performed on wall assemblies with known water control problems as a means to accurately identify suspect wall construction components and details

NAFS Overview

iew verv FS Ov NAF Utilizes ASTM E 547 and/or E 331 for test methodology Test is performed under controlled environmental conditions Test sample is installed strictly per the manufacturer s instructions in a precise test buck opening

NAF FS Ov verv iew Conversion as per NAFS-08 15% for R, LC, CW 20% for AW Water Resistance Test Pressure is capped at 12.00 psf for the U.S. and 15.00 psf for Canada Gateway Requirements Performance Minimum i Minimumi Minimumi Class Design Structural test Water Pressure, Pa pressure, Pa Resistance (psf) (psf) Test Pressure, Pa (psf) R 15.0 22.5 2.90 LC 25.0 37.5 3.75 CW 30.0 45.0 4.50 AW 40.0 60.0 8.00

6.00 PSF (~50 mph) Equivalent hydrostatic water head 1.16 NAFS Overview

7.50 PSF (~55 mph) Equivalent hydrostatic water head 1.44 NAFS Overview

AAMA 502-08 AAMA 502

AAMA 502-90 Original publication by AAMA AAMA 502-02 Added reference to AAMA accredited laboratory and first introduced the 1/3 WTP reduction for water resistance testing of installed products AAM MA 502 AAMA 502-08 Defined newly installed as prior to issuance of the occupancy permit not to exceed 6 months after installation of the fenestration product.

ASTM E 783 Field Measurement of Air Leakage through Installed Exterior Windows and Doors AAM MA 502 ASTM E 1105 Field Determination of Water Penetration of Installed Exterior Windows, Curtain Walls and Doors by Uniform or Cyclic Static Air Pressure Difference

Requires testing agency to report and make adjustments for ambient conditions. In some cases, temporary enclosures are required to reduce adverse effects of wind and temperature at the project site. 502 MA 5 AAM

The default air leakage for quality assurance field testing is 1.5 times the applicable laboratory standard d for the product type and performance class 502 MA 5 AAM

TO OUTSIDE BAROMETRIC PRESSURE ALTERNATE TEST CHAMBER PRESSURE MEASURING DEVICE TEST CHAMBER EXHAUST VALVE AAM MA 502 PRESSURE GAUGE VALVE CALIBRATED WATER SPRAY RACK W THE CHAMBER SHALL NOT BE PERMITTED TO MAKE ANY CONTACT WITH THE FENESTRATION PRODUCT AIR SYSTEM INNERMOST PLANE FOR WATER PENETRATION (REFERENCE PARAGRAPH 4.3.4) 4)

Requires testing agency to report and make adjustments for ambient conditions Test is performed on the entire fenestration product opening 502 MA 5 AAM

The test pressure shall not be less than 91Pa(19psf) (1.9 502 MA 5 AAM Tests shall be conducted at a static test pressure equal to 2/3 of the tested and rated laboratory performance per AAMA/WDMA/CSA 101/I.S. 2/A440

AAM MA 502 1. Newly installed fenestration product(s) shall be field tested in accordance with AAMA 502, "Voluntary Specification for Field Testing of Newly Installed Fenestration Products." 2. Test three (unless otherwise specified) of the fenestration product specimens after the products have been completely installed for air leakage resistance and water penetration resistance as specified. 3. Air leakage resistance tests shall be conducted at a uniform static test pressure of Pa ( psf). The maximum allowable rate of air leakage shall not exceed L/s m2 ( cfm/ft2) 4. Water penetration resistance tests shall be conducted at a static test pressure of Pa ( psf). No water penetration shall occur as defined in Section 4.3.4 of AAMA 502

1/3 reduction to the laboratory rating of the WTP is the default Sill Dam test is removed from 502 and moved to the 511 document 502 MA 5 AAM

Method A Product only testing has been eliminated from the 502-08 and moved to AAMA 511. 502 MA 5 AAM If the source of the water cannot be determined, a forensic evaluation using the procedures outlined in AAMA 511 shall be performed

AAMA 503-08 AAMA 503

AAM MA 503 AAMA 503 was originally published in 1992 AAMA 503 is a similar document to AAMA 502 for Storefronts, Curtain Walls & Sloped Glazing Systems. Updated in 2003 & 2008 AAMA 503-08 Defined newly installed as prior to issuance of the occupancy permit not to exceed 6 months after issuance of the occupancy permit.

AAMA 503

Storefronts Curtain Wall Sloped Glazing AAMA 503

503 MA 5 AAM Curtain Wall Chamber Arrangement

Storefronts Curtain Wall Sloped Glazing AAMA 503

Sloped Glazing Systems Chamber Arrangement 503 MA 5 AAM

Storefronts Curtain Wall Sloped Glazing AAMA 503

Forensic Investigation

ASTM References in AAMA 511 n Fore ensic Inve estig gatio ASTM E 2128, Standard Guide for Evaluating Water Leakage of Building Walls This guide describes methods for determining and evaluating water leakage of exterior walls. A wall is considered a system including its exterior and interior finishes, fenestration, and structural components.

n Fore ensic Inve estig gatio Involves more than just testing The purpose of diagnostic testing is to recreate water leaks that t are known to occur AAMA 511 testing either follows up on AAMA 502 and 503 testing or is used in a water intrusion investigation

n Fore ensic Inve estig gatio The ultimate goal of 511 diagnostic testing is to recreate existing leakage behavior that occurs under in-service conditions.

n Fore ensic Inve estig gatio Four Preliminary Steps prior to testing Review of project documents Evaluation of design concept Determination of service history Inspection Three Steps During and After Testing Investigative Testing Analysis Report

n Fore ensic Inve estig gatio Step #1: Review Project Documents Architectural drawings Structural drawings Shop drawings Installation instructions Contracts Purchase orders Specifications Warranties

n Fore ensic Inve estig gatio Step # 2: Evaluation of Design Concept Water management concept Critical details Test reports Flashing Sealants Weep Holes

n gatio estig c Inve ensic Fore Step # 3: Determination of Service History Review maintenance records Interview knowledgeable personnel Research leak history

n Fore ensic Inve estig gatio Step #4: Inspection Interior observations Exterior observations Observe workmanship Observe product deficiency Develop a hypothesis for the source of the water intrusion

Forensic Investigation

n Fore ensic Inve estig gatio Determination is based on: Field Standards Laboratory Standards Prior Testing Weather Data Experience

n Fore ensic Inve estig gatio Simulate the weather events Obtain wind speed If calculated wind speed is greater then 2/3 of the rated WTP for the product it may be that the product was not the most appropriate for the project. At least one pressure difference test must be done at the 2/3 pressure

n Fore ensic Inve estig gatio ASCE 7 accounts for: Exposure Height above grade Basic wind speed (or weather data) Location of specimen within façade

Forensic Investigation

n gatio estig c Inve ensic Fore The objective of testing is to identify the leak paths

Exam mple 1 MA 511- AAM Consistent leaks more than one year Heaviest leakage twice during September 2005 Class II Building height is 33 ft., window (z) is 27 ft. above ground Window is 4 high x 4 wide, wind area (A) of 16 ft 2 AAMA rating C35

AAMA 511 Example #1

Estimating the Test Pressure Exam mple 1 11- MA 5 AAM ASCE/SEI 7 05 analysis is used with the following information: Location of building (Newark, NJ) Building usage designation (Class II) Exposure level (Exposure B) Building ud gdesign (enclosed structure with a flat roof ) Building height (33 ft.) Window area (16 square ft.) From these features, the water resistance test pressure is, theoretically, 2.4 psf.

Exam mple 1 Local weather data is analyzed by daily readings for September of 2005, allowing the investigator to observe the weather condition, amount of precipitation it ti and maximum wind speed for each day MA 511- AAM

AAMA 511 Example #1

Exam mple 1 11- MA 5 AAM The maximum 5 second gust wind speeds are recorded for every day in September in which measurable rainfall occurred Date Rain Fall (in) Max Wind Speed (mph) 5-Sec. Gust 4-Sep-05 0.12 16 12-Sep-05 0.33 11 21-Sep-05 067 0.67 52

Exam mple 1 11- MA 5 AAM Only two leak events are reported during September 2005 Average wind determined to be 34 mph Date Rain Fall (in) Max Wind Speed (mph) 5-Sec. Gust 4-Sep-05 012 0.12 16 12-Sep-05 0.33 11 21-Sep-05 0.67 52

Exam mple 1 MA 511- AAM Result = 2.1 psf which is the differential pressure used to evaluate the window opening in question Weather data analysis is used to determine field water penetration resistance pressure Table 3 of AAMA/WDMA/CSA 101/I.S. 2/A440 0505 shows tested water penetration resistance pressure The result of the weather data analysis (2.2 psf ) is the differential pressure used to evaluate the window opening in question

Exam mple 2 MA 511- AAM Leak Reported during storm on September 21, 2005 Class II, Exposure C Building height is 60 ft., window (z) is 55 ft. above ground Window is 2 high x 2 wide, wind area (A) of 4 ft2 AAMA rating C35

Estimating the Test Pressure Exam mple 2 11- MA 5 AAM ASCE/SEI 7 05 analysis is used with the following information: i Location of building (Chicago, Il) Building usage designation (Class II) Exposure level (Exposure C) Building design (enclosed structure with a flat roof ) Building height (60 ft.) Window area (4 square ft.) From these features, the water resistance test pressure is, theoretically, 3.2 psf.

Exam mple 2 11- MA 5 AAM Referring to tabulated local weather data above, the investigator can determine and record the maximum 5 second gust speeds on the date of the reported leak Date Rain Fall (in) Max Wind Speed (mph) 5-Sec. Gust 21-Sep-05 0.67 52

11- Exam mple 2 AAM MA 5 52 mph can now be used in Eq. 6 15 from SEI/ASCE 7 05 to establish a wind pressure of 79 7.9 psf Since specimen height is above 60 feet above grade, this wind pressure is inserted into Eq. 6 23 to calculate maximum test pressure Result = 8.4 psf, which is greater than the laboratory water penetration ti resistance it test tpressure of 525 5.25 psf as prescribed for a C 35 product rating. Since calculated differential air test pressure exceeds the rated performance value for the product, investigator shall first perform at least 1 test at 2/3 of the product performance rating prior to testing at calculated pressure.

Interior Weep Holes Water shall cover all horizontal surfaces expected to be wet Tape applied over Exterior Weep Test Water Head measured from bottom of exterior wrap AAMA 511 Example #2

he Le eak reating t Recr Need to determine: How to apply water How long to run test Whether or not to include differential pressure How much air pressure How to step or phase pressure

Recreating the Leak

Recreating the Leak

eak reating the Le Recr How long would you test these substrates?

eak reating the Le Recr Which application best fulfills the objective?

Recreating the Leak

Recreating the Leak

eak reating the Le Recr How does differential pressure affect the test specimen?

eak reating the Le Recr Start with zero differential pressure then step up to higher pressures

Recreating the Leak

Recreating the Leak

ng t he Le eak Recr reati Start testing at lower elevations and work higher Introduce one new element at a time into each new water test Use isolation to protect features from water spray Do not turn the water off at the first moment a leak appears Try to trace the leak from the exterior to the interior and use destructive wall probes as required to identify this leak path Do not end non-leaking tests until you are confident the specimen is not contributing to leakage

he Le eak ng t reati Recr No or limited leak history Leak reported as window leak when leak is actually from another source Not enough water pressure Not able to achieve differential pressure Owner does not want to remove interior finishes No or limited access to concealed wall areas Inclement weather Isolation failures

Identifying the Source

Identifying the Source

Identifying the Source

Identifying the Source

Identifying the Source

Analysis s and Rep porti ng The forensic investigator has the responsibility to make every attempt to ascertain the exact path of water intrusion Conclusions are formed in this step on the basis of the inspection and testing data collected in the previous steps. If conclusions cannot be fully supported by sound scientific principles then additional investigation is needed

Analysis s and Rep porti ng All reports shall be self-contained documents Shall include justification for deviations from the methodology described in the standard The reports shall not include any unsubstantiated opinions or conclusions. If results are not conclusive the forensic investigator shall present options for obtaining conclusive results

Please take a moment to complete the evaluation form. Thank You.