GENERAL PRINCIPLES OF CONSTRUCTION OF AN ENERGY EFFICIENT DATA CENTER FOR AN ORGANIZATION

Size: px
Start display at page:

Download "GENERAL PRINCIPLES OF CONSTRUCTION OF AN ENERGY EFFICIENT DATA CENTER FOR AN ORGANIZATION"

Transcription

1 GENERAL PRINCIPLES OF CONSTRUCTION OF AN ENERGY EFFICIENT DATA CENTER FOR AN ORGANIZATION AUTHOR Mr. S. N. Chavan Retd. A.G.M.(Elec.) S.B.I. & An Electrical Consultant ShreeLakshmi Electro-Tech. India has a biggest treasure of intelligent, dedicated and hard working people. It has become the hub of I.T. activities. Most of the Multinational organizations are out-sourcing their information technology related work to India. In today s fiercely competitive market immediate/speedy service to the customers has gained extreme importance. In this context availability of Information/Data at your finger tips is crucial. Hence the trend has shifted from paper-based to digital information management This involves digital storage whose demand in India has increased exponentially from about 34 Petabytes in 2007 to about 100 petabytes. This demand is growing at a compounded rate of 25-30%. Hence most of the organizations are constructing the Data Centers. Due to the above scenario the adoption of Energy Efficient measures in new and existing Data Centers has become crucial. Different Types of Data Centers Data Centers are basically divided in two categories namely Internet Data Center and Enterprise Data Center. Internet Data Centre ( I.D.C.) Internet Data Centers are also referred to as Colocation & Managed Data Center. These are built & operated by service providers. IDC s are built & maintained by the enterprises whose business is based on internet commerce. The service provider make s an agreement with customers to provide functional support to the customer s I.T equipment. The service provider s IDC infrastructure is similar to that of other type i.e. Enterprise Data Center, however the scalability need of Enterprise Data Centre is smaller because of smaller user base and services provided are comparatively less. Enterprise Data Center Enterprise Data Center s support many functions that enables different business strategies. Enterprise Data Center are evolving and this evolution is partly resulting in new trends mainly because of the criticality of the data held in Datacenters. These trends are use of n-tier, web services and grid computing etc. Due to criticality of operation and maintenance of Data Centers the Telecommunication Association( TIA) has formulated operating standards ( TIA-942) to address the requirements of Data Center Infrastructure. TIA-942 Standards Telecommunication Industry Association (TIA) has developed a TIA-942 standard for planning and building Data Center s particularly with regards to cabling systems and network design by the Data Center designer s & planners. TIA covers the following: 43

2 A. Site Selection & layout B. Cabling Infrastructure C. Reliability D. Environmental Considerations Major Factors in Selection of Site for Data Center A. Power availability B. Preferred Seismic Zone Below Zone 3. C. Adequate water Availability( for Big Data Centers where water cooled cooling systems are provided which are energy efficient) D. Free from security threat. Major advantages of Designing Datacenter s as per TIA-942 standards are as under; A. Standard nomenclature. B. Fail-safe operation. C. Robust protection against natural or human made disaster s. D. Long term reliability, flexibility and scalability. The Data center redundancy is one of the most important factor s in the designing of Data Center. Redundancy in a system design makes available alternate components to provide alternative in case of component failure. Based on the redundancy level maintained in Data Centers, the Data Center s are categorized in to four Tier Levels, namely Tier 1, Tier 2, 3,4 etc. Data Center standards define availability factor of D.C. facility. Classification of Data Center s on basis of their Tier level identifies the different Data Center site design topologies. Tier IV Data Center Infrastructure is considered to be most robust, scalable and failure-proof. Sources Contributing Towards Power Consumption in a Data Center: In a Data Center I.T. equipment s consume about 50% and Air-conditioning equipment s needed for cooling consume almost 37% of total power consumed by the Data Center (D.C.). Remaining 13% is consumed by U.P.S. P.D.U. and other accessories including the lighting. Due to the use of latest high density servers such as blade servers the power consumption has increased from earlier value of around 3-4 K.W.per rack to almost 24 K.W.per rack This has a major impact on the cooling needs of the Data Center resulting in higher demand of power for the same area of Data Center and the consequent increase in energy consumption. Ultimate result is exponential rise in monthly electricity bill of an organization. Hence selection of energy efficient components while modernization/expansion of existing D.C. Or construction of a new D.C. play a significant role. It is a very big topic and in this paper we are confining the issue to the Electrical Components involved in the power network from sub-station to the Server Room of a D.C. Most of the big and reputed organizations are adopting Tier 3 type of Data Centers in India as Tier 4 D.C. needs two different incoming power sub-stations getting incoming power supply from separate feeders coming from different switchyards which is not economically feasible at all the locations. Major electrical components of A Data Center Power Infrastructure are as under : (A) H.T. Circuit Breaker. (B) Step Down Distribution Transformer. (C) L.T. C.B. (D) Main Power Distribution Panel. (E) Diesel Generator. (F) Transient Voltage Surge suppressor/s. (G) U.P.S. with Battery Bank. (H) Automatic Transfer Switches. (I) Sub Distribution Boards (J) Power Distribution Units (P.D.U.) (K) Power Distribution Cables OR Bus-Bar Distribution system. (L) Power Strips in the Server racks. (M) Static Transfer Switches. (N) Grounding. (O) Monitoring Equipment s (B.M.S.)etc. 44

3 (A)& (C) : H.T. & L.T. Circuit Breakers. Energy saving in above breakers is comparatively negligible as compared to the scope in other components and it s major role is to safe guard the Data Center (D.C.) equipment s from any electrical faults in incoming supply or from the load side. They are designed as per the fault level of the power supply utilities and S.C. current levels of the load (for L.T. C.B.). (B) Main Distribution Transformer/ Utility Transformer for a Data Center Transformer is the heart of Power distribution network of any organization. Data Center load increases exponentially due to business needs and for business continuity of an organization adequate spare capacity of transformer needs to be ensured. Secondly, good After-Sales Service with adequate spares at a location nearer to Data Center is a necessity. All Data Centers have Non Linear loads which generate the harmonics which flow from load towards the power source. Transformers are vulnerable to overheating and premature failure due to harmonic currents generated by non linear loads. Hence K-rated transformer which is specifically designed to accommodate harmonic currents need to be selected for a Data Center. These transformers are preferred because they have additional thermal capacity to take care of overheating due to harmonics. Generally, for non-linear loads and computer rooms, the recommended K-factor is 4 to 9. (E) Diesel Generator Diesel generator is used as a backup power source during the grid failure or other failures in power system components of a D.C. Following factors need consideration during selection of a D.G. set for a D.C. 1. Reliability of a D.G. set is gravely impacted under light load conditions which lead to engine damage. Hence, operating a D.G. set below 30% of rated load is never recommended. 2. At high altitudes& high temperatures de-rating of the prime mover to deliver the torque required for full generator output needs to be done. 3. Sizing of a D.G.set depends upon load demand. Stand-by D.G. set generally have no overload capacity. It has a limited 10% overload capacity at intermittent period. In case of a D.C. the D.G. set has to be designed for prime power rating. 4. A leading power factor current can destabilize the D.G. set. The most common sources causing leading p.f. are lightly loaded UPS systems with input filters and power factor correction devices for motors. It is most desirable to ensure that load power factor is supported by the generator. 5. For an energy efficiency of a Data Center a D.G. with lower specific fuel consumption needs to be preferred. 6. Few Energy Saving Measures For D.G. Set Are As Under : A. To ensure availability of cold & dust free air at intake for engine cooling. Air filtration to be improved. B. Parallel operation of D. G. sets with load sharing capability for improving load factor and fuel economy to be given a weightage. C. Fuel injection pumps be calibrated frequently. (F.) Transient Voltage Surge Suppressor : Transient surges are caused mainly by LIGHTNING, SWITCHING & ELECTRICAL FAULTS. Secondary effect of lightning causes transient Over voltages which damage sensitive electrical and electronic equipment s installed in a D.C. The commonly used protective devices like H.R.C. fuses, M.C.B s, E.L.C.B s etc are current sensing devices and they sense & operate in few milli seconds. As the surge is a Transient Over Voltage which occurs for a few micro seconds these devices can not sense them. Hence, Indian & international standards recommend installation of Surge Protection devices at the input of the U.P.S. and the associated By-pass circuits ( including manual By- pass circuit) as well as connected branch panel. As critical loads are installed in a D.C. provision of TVSS is now mandatory. 45

4 (G) Selection of U.P.S. & Batteries Commercial power containing spikes, sags, and outages would cause Loss Of Valuable Data and severe damage to I.T. infrastructure in a Data Center. U.P.S. is one of the critical equipment in operation of a Data Center. Among the various types of U.P.S. systems ON-LINE U.P.S. model is preferred in the D.C. Apart from the reliability the Efficiency of an U.P.S. system becomes a major consideration. An U.P.S. has an incomer power transformer which should be K- rated to take care of harmonics generated by the Non linear loads in the D.C. Efficiency of an U.P.S. depends upon loading of U.P.S. Efficiency is maximum at full loads and falls sharply as the load decreases. For Reliability & Business Continuity very often N+1 combination of U.P.S. is used in a smaller and Tier 2 D.C. s. In this case the total load of a D.C.is shared equally by both the U.P.S. who get Incoming supply from a single common source. However, breakdown in the common incoming supply to both the U.P.S. will still cause shutdown of the D.C. In the case of Tier 3&4 D.C. an N+N model of U.P.S. system (where in both the U.P.S. get supply which is independent from each other) is implemented. Here also both the U.P.S. can be loaded up to Max. 45% of their rated capacity so that in the event of power failure on In- coming side of one of the U.P.S. causing its tripping the other U.P.S. will take over the full load of the D.C. with a total loading of 90%. For a design of an energy efficient U.P.S. for a D.C. it is essential to specify an efficiency of 90% at 30% load and an efficiency of minimum of 92% at 60% and above loading, which is possible and some of the manufacturers are manufacturing such U.P.S. Normally, the current harmonics in an U.P.S. at full load is designed to be 10% and at lower loads the percentage of current harmonics increase. However, as stated above in Tier 3 and 4 Data Center s the load on both the U.P.S. is shared equally and is normally below 50% and hence it is essential to specify 5% current harmonics at 50% loading which is feasible. Third major point is to specify the crest factor of around 3 as against 2.5 normally provided by all. In India the voltage fluctuation at times is very wide and hence specifying In coming voltage range of 415V 20% and 415 V + 15% for a reliable energy efficient U.P.S. is an ideal specification. Galvanic isolation by double conversion of supply initially from A.C. to D.C.( rectification) and then from D.C. to A.C.(Inversion) and use of 12 pulse I.G.B.T. is an added essential requirement in the design of a most reliable and energy efficient U.P.S. For maximum energy efficiency and reliability the latest modular U.P.S which are normally transformer less are given preference. Each module can be of as low as 1 K.V.A and as high as 50 K.V.A. These modules are hot swappable. Back up power to U.P.S. in case of failure of Utility Power supply and taking over by the Auxiliary/Standby source is provided by the batteries. Among Various types of batteries such as Lead Acid, Tubular and Sealed Maintenance Free ( S.M.F.) the S.M.F. is a preferred choice. Of late latest technology & battery less U.P.S. systems are slowly gaining importance and are being used. (H), (I ), (J) : Automatic Transfer Switches. ( A.T.S.) Sub-Distribution Boards & Power Distribution Units ( P.D.U.) : (H) : Automatic Transfer Switches : Automatic Transfer switches (A.T.S.) are recommended when no down time from power outage is tolerated. The A.T.S. enables the redundant U.P.S., back up Generators, D.C. to A.C. invertors, and other A.C. power sources etc. to be used for a single source in a D.C. The A.T.S. & accessories shall confirm to the requirements of UL1008 standards, NEPA 70 & 110,IEE 446, etc. (K )& (L) : Power Distribution Cables/ Bus-Bars & Power Strips in a Server Rack. Depending upon total floor height and clearance available between the base floor and false floor, the obstructions etc. Server Racks are connected to P.D.U. s either by the Power cables Or by an under floor Bus-Bar system having Tap-off boxes. Similarly, the P.D.U. s get the incoming power supply from the sub-distribution boards either through the power cables or the Over-head /under floor bus-bar system with tap-off boxes. Each server rack has two power strip which get incoming power supply through two different U.P.S. systems and dual power racks are plugged in to these power strips which ensures continuous power supply 46

5 to the critical servers. Modern power strips are equipped with a master Circuit Breaker and 8/12/16 sockets with a load manager which displays voltage, current consumed by the power strip which helps in effective monitoring of Data Center loads. (M) : Static Transfer Switches In a Data Centre some of the communication equipment s have only one In-built power supply source and are susceptible to failures. To prevent such an eventuality a Static Transfer Switch is provided. Function of S.T.S. is similar to A.T.S. It receives incoming power from two different U.P.S. and delivers continuous power to single supply source devices. (N) : Grounding In a D.C. all the equipment s have to be at the same potential to prevent any circulating current and the potential difference to protect sensitive electronic equipment s. Accordingly, the false floor metallic grid, server racks, U.P.S., D.B. s etc are all connected together to a common earth grid inside a D.C. On ground floor multiple earth pits are connected in a grid and two separate insulated power cables of adequate capacity depending on D.C. load run from the ground earthing grid to the D.C earthing grid and are solidly connected to each other. (O) : Monitoring/ B.M.S. system All the electrical, A.C. Fire, C.C.T.V.and Access control systems etc. are connected by the control cables to a B.M.S. system which effectively monitors satisfactory operation of all the equipment s in a Data Center. Thus planning and design of a modern Data Center is a challenging job and needs detailed and thorough study of each and every equipment to determine it s exact utility to ensure business continuity and energy efficiency. 47

6 INDEX TO ADVERTISERS ABB India Ltd. 12 ABB India Ltd. 73 Anchor Panasonic 76 ASCO Power Technologies Front Inside Cover Ashida Electronics Pvt. Ltd. 74 Classic Electricals 9 Crompton Greaves Ltd. DEIF India Pvt. Ltd. Back Inside Cover Back Cover Dynatek 97 Electronicon Systems 92 Elleys Industries (I) Pvt. Ltd. 75 Energy Economics 92 Galaxy Earthing Electrodes 91 Global Power System Engineers 89 GRD Power Corporation 10 HPL 94 KNX Madhura International Polycab Wires Pvt. Ltd. vii v Gatefold Back Cover Power Control Electro Sysems 96 Prolite Autoglo Limited R.R. Kabel iii Gatefold Front Cover Seva Engg 97 Shree Engineering 11 Shreem Electric Ltd. 95 Telawane Power Equipments Pvt. Ltd. 90 Visa Power Tech 93 48

Opportunity of Energy Saving in electrical path is lesser as compared to other areas

Opportunity of Energy Saving in electrical path is lesser as compared to other areas Data Centre Power Map ` Energy Optimization Techniques Data Center Power Chain Venkat Rao B Country Manager Power Products Data Center Power Draws Cooling About 35 40 % Sources of Energy Waste Fans / Blowers

More information

Power Distribution Considerations for Data Center Racks

Power Distribution Considerations for Data Center Racks Power Distribution Considerations for Data Center Racks Power Distribution Considerations for Data Center Racks Table of Contents 3 Overview 4 At what voltage do you run all the IT equipment? 4 What electrical

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management. AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled

More information

Galaxy VM. Three-phase power protection. schneider-electric.com

Galaxy VM. Three-phase power protection. schneider-electric.com Galaxy VM Three-phase power protection schneider-electric.com 2 schneider-electric.com schneider-electric.com 3 Galaxy VM trusted partner for your business continuity Features and benefits Highly efficient,

More information

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES UNINTERRUPTIBLE POWER SUPPLIES 9900A >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES 9900A The 9900A UPS system uses the most advanced IGBT in both the converter and inverter with Digital Signal Processor (DSP)

More information

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management. AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled

More information

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers CEMEP UPS The high environmental performance solution for power supply to high-availability data centers Exchanges of information and communication needs are growing at an exponential rate. That growth

More information

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009 Optimum Climate Control For Datacenter - Case Study T. Prabu March 17 th 2009 Agenda 2 About EDEC (Emerson) Facility Data Center Details Design Considerations & Challenges Layout Design CFD Analysis Of

More information

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS Capacity Technology Inverter Technology Noise Level Operating Temperature Humidity Harmonic Distortion Total DC bus voltage Battery recharge time (After Complete discharge) to 100% charge Crest Factor

More information

415V DISTRIBUTION FOR GREEN DATA CENTERS

415V DISTRIBUTION FOR GREEN DATA CENTERS White Paper: HMRP-WP001-A5 June 5, 2012 415V DISTRIBUTION FOR GREEN DATA CENTERS Prepared by: Anthony (Tony) Hoevenaars, P. Eng President and CEO Mirus International Inc. Copyright 2012 Mirus International

More information

RVH/BCH Data Centres Proposals for Surge Protection and Ventilation

RVH/BCH Data Centres Proposals for Surge Protection and Ventilation REPORT Proposals for Surge Protection and Ventilation BELFAST HEALTH AND SOCIAL CARE TRUST ROYAL GROUP OF HOSPITALS GROSVENOR ROAD BELFAST BT12 6BA Rev. 01 6th September 2013 Table of Contents 1.0 Ventilation

More information

Zone B: comprises of NOC room, reception area, Help Desk area, Call Centre, Testing/Monitoring room. This zone requires approximately 1500 sq. feet.

Zone B: comprises of NOC room, reception area, Help Desk area, Call Centre, Testing/Monitoring room. This zone requires approximately 1500 sq. feet. Annexure 1 Best practices and Guidelines to Physical Security of the State Data Centre The Data Centre should ideally be built in a central location within the building complex. An approximate area of

More information

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management. AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled

More information

Power to the adaptable data center

Power to the adaptable data center Business Unit Manager, Data Center Solutions, Eaton s electrical group IT managers have more options than ever to tailor the power infrastructure to their unique data center and business requirements.

More information

Building a Tier 4 Data Center on a Tier 1 Budget

Building a Tier 4 Data Center on a Tier 1 Budget Building a Tier 4 Data Center on a Tier 1 Budget A Walk Through of TIA-942 Peter P. Charland III, RCDD/NTS/WD, CET RTKL Associates Inc. March 27, 2008 BICSI South Central Region Meeting Denver, CO TIA-942

More information

Fundamentals of Power

Fundamentals of Power Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At

More information

The Different Types of UPS Systems

The Different Types of UPS Systems The Different Types of UPS Systems By Neil Rasmussen White Paper #1 Revision 5 Executive Summary There is much confusion in the marketplace about the different types of UPS systems and their characteristics.

More information

UPS Topologies & Architectures. Don Lemmon Tubbesing Solutions (214) 690-6866 [email protected]

UPS Topologies & Architectures. Don Lemmon Tubbesing Solutions (214) 690-6866 don@tubbesing.com UPS Topologies & Architectures Don Lemmon Tubbesing Solutions (214) 690-6866 [email protected] Tubbesing Solutions & Tubbesing Solutions Mike Farrell Mobile No. (214) 355-0493 Tubbesing Solutions Portfolio

More information

Building a data center. C R Srinivasan Tata Communications

Building a data center. C R Srinivasan Tata Communications Building a data center C R Srinivasan Tata Communications Introduction Data Center as defined by TIA 942 A building or a portion of a building whose primary function is to house a computer room and its

More information

Specifying a Variable Frequency Drive s

Specifying a Variable Frequency Drive s Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable

More information

South Asia s First Uptime Institute Certified TIER- IV IDC in Mumbai delivering 99.999% uptime

South Asia s First Uptime Institute Certified TIER- IV IDC in Mumbai delivering 99.999% uptime South Asia s First Uptime Institute Certified TIER- IV IDC in Mumbai delivering 99.999% uptime GPX India Pvt Ltd The Leader In Carrier Neutral TIER IV IDC s In Emerging Markets Incorporated in August 2002,

More information

Intelligent Power Distribution in the Data Center

Intelligent Power Distribution in the Data Center Rack Power Intelligent Power Distribution in the Data Center Agenda Data Centre Power UPS Power Distribution Rack Mount PDU s UPS Power problems Configuration Capacity Power Distribution Types of Distribution

More information

30-120 3 Phase Modular Finally the benefits of Modular ups are for all

30-120 3 Phase Modular Finally the benefits of Modular ups are for all MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion

More information

Data Center Commissioning: What you need to know

Data Center Commissioning: What you need to know Data Center Commissioning: What you need to know Course # CXENERGY1511 AIA Provider # 50111116 AABC Commissioning Group CxEnergy Conference Henderson, NV April 30, 2015 Presented by: Judson H. Adams, P.E.,

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Harmonics in your electrical system

Harmonics in your electrical system Harmonics in your electrical system What they are, how they can be harmful, and what to do about them Abstract Harmonic currents, generated by non-linear electronic loads, increase power system heat losses

More information

415V DISTRIBUTION FOR GREEN DATA CENTERS

415V DISTRIBUTION FOR GREEN DATA CENTERS White Paper: HMRP-WP001-A1 October 1, 2010 415V DISTRIBUTION FOR GREEN DATA CENTERS Prepared by: Anthony (Tony) Hoevenaars, P. Eng President and CEO Mirus International Inc. Copyright 2005 Mirus International

More information

Data Centre Testing and Commissioning

Data Centre Testing and Commissioning Data Centre Testing and Commissioning What is Testing and Commissioning? Commissioning provides a systematic and rigorous set of tests tailored to suit the specific design. It is a process designed to

More information

Electrical Systems. <Presenter>

Electrical Systems. <Presenter> Review Root Causes of Energy Inefficiency Roadmap to Maximize Energy Efficiency Best Practices Alternative Energy Sources Controls Take Aways Seek Professional Help. ENERGY INEFFICIENCY OF

More information

Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria

Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria Tier 3+ 1 Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria Abstract: Schoolcraft College is constructing a High Availability (HA) Data Center

More information

LAP ENERGIA PARA DATACENTERS

LAP ENERGIA PARA DATACENTERS LAP ENERGIA PARA DATACENTERS Latin American Power. CABA, Argentina. 2 UPS INDOOR Latin American Power. CABA, Argentina. ALI ELITE SERIES Line Interactive UPS Tower/19 Rack Mount Versions 19 Rack Mount

More information

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690 V - 1000 V (at 50 Hz)

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690 V - 1000 V (at 50 Hz) 24 1. NETWORK CONFIGURATIONS definition Standard IEC 38 defines voltage ratings as follows: - Low voltage () For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690

More information

OPERATOR - FACILITY ADDRESS - DATE

OPERATOR - FACILITY ADDRESS - DATE . Facility Criteria (RFP).0 Location Characteristics Criteria Requirements 1 Ownership and Management: Please identify the owner(s) and managers of the property and indicate if there is on-site management.

More information

21 st Century Facilities

21 st Century Facilities Electrical Testing 21 st Century Facilities Facility Owners face tough challenges 24 X 7 reliability needed Non linear loads cause harmonics VFD Computers Switching transients disrupt operations Less customer

More information

Safeguard your critical IT assets in a highly secure, fully redundant, environmentally-conditioned and constantly monitored hosting space to receive

Safeguard your critical IT assets in a highly secure, fully redundant, environmentally-conditioned and constantly monitored hosting space to receive Co-Location Services Safeguard your critical IT assets in a highly secure, fully redundant, environmentally-conditioned and constantly monitored hosting space to receive optimum performance 24x7. SERVICE

More information

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications W H I T E P A P E R Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications Executive Summary One of the fundamental decisions in the design of data centers, server rooms

More information

Wireless Networks and Power Quality

Wireless Networks and Power Quality Will installing wireless networking change my back-up power requirements? What data do I need to know in order to determine my wireless network back-up power requirements? What other issues should I consider

More information

Power Quality. Uninterruptible Power Supply

Power Quality. Uninterruptible Power Supply Quality Uninterruptible Supply In the electrical system environment, power disturbances will occur. These can be caused by faults on the distribution system, the operation of nearby equipment, lightning

More information

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M Power Protection for Business Critical Continuity Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications Compact Three-phase UPS with Optimum Load Performance And

More information

SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /

More information

Power Quality for Information Technology System

Power Quality for Information Technology System Power Quality for Information Technology System ITS OBVIOUS THE TOLERANCE IS DIFFRENT But What isn t Tobvious? HOW MANY OF YOU HAVE : A COMPUTER AT HOME? = Computers are not screens and Keyboards COMPUTERS

More information

Increased power protection with parallel UPS configurations

Increased power protection with parallel UPS configurations Increased power protection with parallel UPS configurations Making the selection between Centralized Bypass and Distributed Bypass systems Janne Paananen Application Engineer, Large Systems Group Eaton

More information

PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR

PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR CLASSIFICATION CLASSIFICATION ACC. TO - AEG S UPS PRODUCT PORTFOLIO - IT S APPLICATION ORIENTED USE - UPS PRODUCT

More information

Optimizing Power Distribution for High-Density Computing

Optimizing Power Distribution for High-Density Computing Optimizing Power Distribution for High-Density Computing Choosing the right power distribution units for today and preparing for the future By Michael Camesano Product Manager Eaton Corporation Executive

More information

Power Management Module 2. Installation

Power Management Module 2. Installation Power Management Module 2 30 300 kva Installation Table of Contents Safety... 1 Safety Instructions... 1 Certification Standards Three Phase... 1 Product Safety... 2 Special Precautions... 2 System Description...

More information

South Asia s First Uptime Institute Certified TIER-IV IDC in Mumbai delivering 99.999% guaranteed uptime

South Asia s First Uptime Institute Certified TIER-IV IDC in Mumbai delivering 99.999% guaranteed uptime South Asia s First Uptime Institute Certified TIER-IV IDC in Mumbai delivering 99.999% guaranteed uptime GPX India Pvt Ltd The Leader In Carrier Neutral TIER IV IDC s In Emerging Markets Incorporated in

More information

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group www.6dg.co.uk

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group www.6dg.co.uk Dedicated managed environment for mission critical services www.6dg.co.uk Our datacentres are the core of our business. At we own and manage 30,000 square feet of highly available, geographically diverse

More information

MGE Galaxy 7000. 160/200/250/300/400/500 kva Power efficiency for business continuity

MGE Galaxy 7000. 160/200/250/300/400/500 kva Power efficiency for business continuity MGE Galaxy 7000 160/200/250/300/400/500 kva Power efficiency for business continuity Performance three-phase power protection with high adaptability to meet the unique requirements of medium to large data

More information

SSPI-APPN OTES: PARALLEL C ONNECTIONS

SSPI-APPN OTES: PARALLEL C ONNECTIONS There are two distinct reasons to connect power supplies in parallel: Current Sharing and Redundancy. Combining of these reasons is common, and there are many ways to implement them. The unique considerations

More information

Managing Cooling Capacity & Redundancy In Data Centers Today

Managing Cooling Capacity & Redundancy In Data Centers Today Managing Cooling Capacity & Redundancy In Data Centers Today About AdaptivCOOL 15+ Years Thermal & Airflow Expertise Global Presence U.S., India, Japan, China Standards & Compliances: ISO 9001:2008 RoHS

More information

Data center power dynamics within the settings of regional power grid

Data center power dynamics within the settings of regional power grid Data center power dynamics within the settings of regional power grid Gulnara Zhabelova 1, Alireza Yavarian 1, Valeriy Vyatkin 1,2 1 Department of Computer Science, Electrical and Space Engineering Lulea

More information

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings *** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not

More information

The Different Types of UPS Systems

The Different Types of UPS Systems White Paper 1 Revision 7 by Neil Rasmussen > Executive summary There is much confusion in the marketplace about the different types of UPS systems and their characteristics. Each of these UPS types is

More information

ENGINEERING REPORT. XYZ Corporation 100 Anyplace Drive Chicago, Illinois 60613

ENGINEERING REPORT. XYZ Corporation 100 Anyplace Drive Chicago, Illinois 60613 ENGINEERING REPORT XYZ Corporation 100 Anyplace Drive Chicago, Illinois 60613 PERFORMED BY: MIDWEST ELECTRICAL CONSULTANTS, INC 18055 UPLAND DRIVE TINLEY PARK, ILLINOIS 60487 (708) 444-0001 fax: 444-0003

More information

PowerGem Pro Uninterruptible Power Supply

PowerGem Pro Uninterruptible Power Supply Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity

More information

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Increasing Data Center Efficiency by Using Improved High Density Power Distribution Increasing Data Center Efficiency by Using Improved High Density Power Distribution By Neil Rasmussen White Paper #128 Executive Summary A new approach to power distribution for high density server installations

More information

Calculating Total Power Requirements for Data Centers

Calculating Total Power Requirements for Data Centers Calculating Total Power Requirements for Data Centers By Richard Sawyer White Paper #3 Executive Summary Part of data center planning and design is to align the power and cooling requirements of the IT

More information

Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work.

Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work. Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work. Data security is first of all electrical Maximizing security while providing efficiency

More information

Isolated-Parallel UPS Configuration

Isolated-Parallel UPS Configuration Isolated-Parallel UPS Configuration 1 Inhalt 1 Introduction... 4 2 IP systems configuration... 6 3 Projects... 17 4 Conclusions... 17 2 Abstract The isolated-parallel UPS configuration has become well

More information

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME 2 AGENDA SESSION -1 What is Data Center? SESSION -2 Equipment and Components SESSION -3 Standard in designing Data Center

More information

SG Series UPS 10-150 kva. high efficiency systems

SG Series UPS 10-150 kva. high efficiency systems SG Series UPS 10-150 kva high efficiency systems Touching all Areas of the Energy Industry With more than 100,000 employees in over 100 countries, GE s diverse portfolio of products and services is helping

More information

APC 3Phase Power Distribution

APC 3Phase Power Distribution APC 3Phase Power Distribution North American 3 Phase Business Development Team All content in this presentation is protected 2008 American Power Conversion Corporation Objectives Understand the entire

More information

Automation's Modular Containerized Datacenter Solutions

Automation's Modular Containerized Datacenter Solutions SAFE Automation's Modular Containerized Datacenter Solutions Automation's SAFE (Secure, Autonomous, Flexible, Efficient) Modular Containerized Datacenter offers a fast, flexible and efficient solution

More information

GE Digital Energy. TLE Series UPS. 160-400 kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

GE Digital Energy. TLE Series UPS. 160-400 kw three phase 400 Vac. with best-in-class efficiency. gimagination at work GE Digital Energy TLE Series UPS 160-400 kw three phase 400 Vac with best-in-class efficiency gimagination at work GE provides clean, efficient and reliable power for today s digital world with the ultra

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information

Always On UPS Systems Inc., #100-150 Campion Road, Kelowna, BC Canada V1X 7S8

Always On UPS Systems Inc., #100-150 Campion Road, Kelowna, BC Canada V1X 7S8 Door Mount UPS (Patent Pending) Shelf Mount UPS (Patent Pending) DESCRIPTION: The Always On NDM (door mount) and NSM (shelf mount) Series UPS s are dual conversion online UPS systems provided in slim,

More information

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY The Aegis Services Power and Assessment Service provides an assessment and analysis of your data center facility and critical physical

More information

RIELLO ELETTRONICA. Master HP

RIELLO ELETTRONICA. Master HP RIELLO ELETTRONICA Master HP LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTRES TELECOM- MUNICATIONS DEVICES E-BUSINESS (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCS ELECTRO- MEDICAL DEVICES

More information

The Different Types of UPS Systems

The Different Types of UPS Systems Systems White Paper 1 Revision 6 by Neil Rasmussen Contents Click on a section to jump to it > Executive summary There is much confusion in the marketplace about the different types of UPS systems and

More information

The Anatomy of a. High-Availability Rack. November 2009. Online Tech, Inc. 220 E. Huron Ann Arbor, MI 48104 (734) 213-2020. www.onlinetech.

The Anatomy of a. High-Availability Rack. November 2009. Online Tech, Inc. 220 E. Huron Ann Arbor, MI 48104 (734) 213-2020. www.onlinetech. Online Technologies Corporation September 2008 If you have questions, please contact: The Anatomy of a Onl (734) 213-2020 phone High-Availability Rack November 2009 Online Tech, Inc. 220 E. Huron Ann Arbor,

More information

Common Power Problems & Power Protection Solutions

Common Power Problems & Power Protection Solutions W H I T E P A P E R Common Power Problems & Power Protection Solutions Executive Summary All systems, from home theaters and office desktops to enterprise IT equipment in data centers, are prone to downtime,

More information

DISTRIBUTED REDUNDANCY:

DISTRIBUTED REDUNDANCY: DISTRIBUTED REDUNDANCY: MAXIMUM AVAILABILITY AT MINIMAL COST A White Paper by: Liebert Corporation As the need for greater system availability intensifies across virtually every industry from global banking

More information

ACTURA 4855. -48 V DC, 3-40 kw, 60-800 A. The Regional DC power system with Global Muscle

ACTURA 4855. -48 V DC, 3-40 kw, 60-800 A. The Regional DC power system with Global Muscle ACTURA 4855-48 V DC, 3-40 kw, 60-800 A The Regional DC power system with Global Muscle Reliability or Price Efficiency? Now you can have both! Customized power systems with high reliability at a competitive

More information

Increasing safety, reliability and efficiency for today s data centers

Increasing safety, reliability and efficiency for today s data centers Increasing safety, reliability and efficiency for today s data centers Products and expertise for data center success Drawing upon vast experience in complex industries where uptime is critical, ABB provides

More information

Comparative study for cables and busbars

Comparative study for cables and busbars Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary

More information

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Variable Frequency Drives - a Comparison of VSI versus LCI Systems Variable Frequency Drives - a Comparison of VSI versus LCI Systems Introduction TMEIC is a leader in the innovative design and manufacture of large ac variable f requency drive systems. TMEIC has been

More information

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants Installation instructions Contents Key points of installation Before installation Installation Installation check

More information

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Reference Guide: SmartDesign Approach: Common Data Center Challenges: Smart Solutions Reference Guide Solutions For Business-Critical Continuity 1100kW Tier 3 With High Density Design Intelligent, Integrated Infrastructure for the Data Center Reference Guide: 1100kW Tier

More information

Applications for Infrared Thermography at Computer Centers

Applications for Infrared Thermography at Computer Centers Applications for Infrared Thermography at Computer Centers By Eric Stockton CompuSCANIR, a division of Stockton Infrared Thermographic Services, Inc. 8472 Adams Farm Road Randleman, NC 27317 http://www.compuscanir.com/

More information

Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理. Schneider Electric - Division - Name Date

Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理. Schneider Electric - Division - Name Date Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理 1 Agenda 1 2 3 相 UPS 總 覽 Introduction & Overview of 3 Phase UPS 理 解 客 戶 最 大 的 考 量 點 Understanding Top Customer Concerns 3 Galaxy VM 關 鍵 技 術 創

More information

Consulting Engineering Outsourcing

Consulting Engineering Outsourcing Consulting Engineering Outsourcing Opportunities, challenges and strategies 5.º Fórum Lusófono das Comunicações Maputo, 24 de Abril de 2014 Maksen 2014 Consulting Engineering Outsourcing AGENDA 01. Data

More information

TLE Series UPS 160-800 kva/kw three phase 400 Vac with best-in-class efficiency

TLE Series UPS 160-800 kva/kw three phase 400 Vac with best-in-class efficiency GE Critical Power TLE Series UPS 160-800 kva/kw three phase 400 Vac with best-in-class efficiency imagination at work GE provides clean, efficient and reliable power for today s digital world with the

More information

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION Please read and understand the product instruction manual before installing, servicing or operating Yaskawa products. Technical content

More information

LEVEL 3 DATA CENTER ASSESSMENT

LEVEL 3 DATA CENTER ASSESSMENT Nationwide Services Corporate Headquarters 410 Forest Street Marlborough, MA 01752 USA Tel: 800-342-5332 Fax: 508-303-0579 www.eecnet.com LEVEL 3 DATA CENTER ASSESSMENT Submitted by: Electronic Environments

More information

DESIGNING DATA CENTERS & SERVER ROOMS

DESIGNING DATA CENTERS & SERVER ROOMS DESIGNING DATA CENTERS & SERVER ROOMS Compton s Designing Data Center Services are an enterprise-wide, consultative approach to help you manage mission critical environments. The services encompass the

More information

Circuit Breakers in Data Centers: The Hidden Danger

Circuit Breakers in Data Centers: The Hidden Danger Circuit Breakers in Data Centers: The Hidden Danger How to efficiently protect critical IT equipment by choosing the most reliable overcurrent protection device for your Rack Power Distribution Unit. By

More information

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications ZP110 on-line UPS 1, 2, 3, 6, 10kVA single/single phase LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs Emergency Devices (Lights/Alarms) Electro-Medical Devices

More information

Datacentre London 1. Dedicated managed environment for mission critical services. Six Degrees Group www.6dg.co.uk

Datacentre London 1. Dedicated managed environment for mission critical services. Six Degrees Group www.6dg.co.uk Dedicated managed environment for mission critical services www.6dg.co.uk Our datacentres are the core of our business. At we own and manage 30,000 square feet of highly available, geographically diverse

More information

High-density modular data center making cloud easier. Frank Zheng Huawei

High-density modular data center making cloud easier. Frank Zheng Huawei High-density modular data center making cloud easier Frank Zheng Huawei 2012-10-10 Content 1 2 3 4 Cloud s impact to data center Concerns of DC construction 4S DC making cloud easier Success stories Cloud?

More information

Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM

Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM Power Management Strategies for High-Density IT Facilities and Systems A White Paper from the Experts in Business-Critical Continuity TM Executive Summary Increases in data center density and diversity

More information

Eaton 93PM UPS Where aesthetics meet intelligence.

Eaton 93PM UPS Where aesthetics meet intelligence. Brochure 100 kw Eaton 93PM UPS Where aesthetics meet intelligence. 93PM features and benefits The Eaton 93PM UPS combines unprecedented and reliability with eye-catching design. A space-saving, flexible

More information

CONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 2

CONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 2 IT Power Solutions CONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 2 Thomas B. Jones 1 Introduction Operators and managers consider outages, operational

More information

SG Series UPS 10-600 kva three phase 400 Vac

SG Series UPS 10-600 kva three phase 400 Vac GE Critical Power SG Series UPS 10-600 kva three phase 400 Vac with ultra-high efficiency eboost TM technology imagination at work From protecting assets such as generators, transmission lines and motors,

More information

National Aluminium Co. Ltd.

National Aluminium Co. Ltd. National Aluminium Co. Ltd. [NALCO] EXPRESSION OF INTEREST FOR DATA CENTRE CO-LOCATION SERVICES Address for Communication The Project Manager ERP P/1, NALCO BHAWAN NAYAPALLI, BHUBANESWAR 751061 E mail:

More information

in other campus buildings and at remote campus locations. This outage would include Internet access at the main campus.

in other campus buildings and at remote campus locations. This outage would include Internet access at the main campus. DATA CENTER The current Campus Data Center is located within historic Founders Hall which is in a less-than ideal location for a variety of reasons, but is typical of an existing campus IT infrastructure

More information