SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION
|
|
|
- Caroline McKinney
- 9 years ago
- Views:
Transcription
1 SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION Please read and understand the product instruction manual before installing, servicing or operating Yaskawa products. Technical content and illustrations are provided as technical advice to augment the information in the manual, not supersede it. It is not possible to give detailed instruction for all types of installation or support activities. The information described in this document is subject to change without notice. Yaskawa assumes no responsibility for errors, omissions or damages resulting from the use of the information contained in any technical document. All warnings, cautions and product instruction for product use must be followed. Installation, operation and maintenance should be carried out by qualified personnel. Failure to observe these and other precautions highlighted in the product manuals will expose the user to high voltages resulting in serious injury or death. Qualified personnel are defined as individuals who are familiar with the installation, starting, operation, and maintenance of Yaskawa products of the type described and has proper qualifications to perform the work. June 14, 2010 Copyright Yaskawa America, INC of 12
2 INTRODUCTION VFD Use with Single-Phase Power Systems Most commercial and industrial electrical equipment requires three-phase power based on electrical demand of heavy manufacturing population and general industry. In rural areas or commercial office buildings that were not originally designed to support heavy manufacturing, utilities do not install three-phase power because the cost is significantly more than single-phase installation. For many years, people have been using different technology to generate three-phase power from single-phase sources. Common technologies include rotary phase converters, static phase converters and variable frequency drives (VFDs). As initial investment costs of VFDs have lowered and product reliability has increased, more users are turning to VFDs as the best solution to convert single-phase motor applications to three-phase, because their process demands have changed requiring variable speed control. Common applications utilizing VFDs with single-phase input are submersible well pumps, centrifugal pumps, irrigation systems, fountain systems, and pump jacks. Using VFDs specifically designed for single-phase use is not always practical as manufacturers may offer single-phase models only in low horsepower ratings. Therefore, it may be necessary to apply a three-phase VFD in larger capacity single-phase situations. When applying single-phase power to a three-phase VFD, there are several constraints that need to be considered. Standard Pulse-Width-Modulated (PWM) VFDs use a 6-pulse diode rectifier because of its simplicity and low cost structure. The 6-pulse rectification results in 360 Hz DC bus ripple when used with a three-phase 60 Hz supply. However, under single-phase use, the DC bus ripple becomes 120 Hz and the VFDs DC bus circuit is subject to higher stress in order to deliver equivalent power. Additionally, input currents and harmonics increase beyond those encountered with three-phase input. Input current distortion of 90% THD and greater can be expected under single-phase input, compared to approximately 40% with three-phase input as indicated in Figure 2.0. Therefore, single-phase use requires the three-phase VFD power rating be reduced (derated) to avoid over stressing the rectifier and DC link components. June 14, 2010 Copyright Yaskawa America, INC of 12
3 Figure 1.0 Typical Three-Phase Configuration DCL Figure 2.0 Typical Single-Phase Configuration DC capacitor 1-phase input June 14, 2010 Copyright Yaskawa America, INC of 12
4 Important Considerations When Using a Three-Phase Drive with Single-Phase Input Yaskawa E7, F7, and P7 drives have been tested and UL approved for single-phase input power applications provided that an appropriate derate is applied. It is imperative that the guidelines outlined in this document are followed to determine the correct drive selection for the connected motor and load, ensuring satisfactory operation and drive longevity. Drive HP, Input Current and Output Current When using a three-phase VFD with single-phase input, derating the drive s output current and horsepower will be necessary because of the increase in DC bus ripple voltage and current. In addition, the input current through the remaining two phases on the diode bridge converter will approximately double, creating another derating consideration for the VFD. The increase in input current is due to the conversion of three-phase to single-phase power ( 3 factor) and the reduced overall power factor. Input current harmonic distortion will increase beyond that with a three-phase supply making the overall input power factor low. An overall power factor of 0.7 is typical with single-phase input on units incorporating the recommended DC link choke. A power factor of 0.9 is typical with units incorporating DC link chokes with three-phase input. Input current distortion over 100% is likely under single-phase conditions without a DC link choke. Therefore, DC link chokes are always required. Use Table 1 to select the appropriate drive and DC link choke for the applied motor. As indicated in Table 1, Yaskawa VFDs larger than 18 kw incorporate built-in DC link chokes as standard. Therefore, these models will not require external DC link chokes. Be sure to oversize the drive as necessary to accommodate for operating the motor into its service factor. The selected drive ratings must meet or exceed both the motor nameplate HP and the motor nameplate full load amperage (FLA), along with satisfying any service factor HP and FLA requirements. Selecting a drive that meets only one of these two requirements may result in poor performance, premature drive failure and void the factory warranty. Input Frequency and Voltage Tolerance The drive ratings in Table 1 are valid for 60Hz input only. Operation at input frequencies other than 60Hz will require further review by the factory. The AC supply voltage must be within the required voltage range of 240/480Vac +10% to 5% to maximize motor power production. Standard product with three-phase voltage input has an allowable range of +10% to 15%. Therefore, a stricter input voltage tolerance of +10 to 5% applies when using the drive with a single-phase supply. The average bus voltage with single-phase input is lower than the equivalent of a three-phase input. Therefore, the maximum output voltage (motor voltage) will be lower with a single-phase input. The minimum input voltage must be no less than 228Vac for 240 volt models and 456Vac for 480 volt models, to ensure motor voltage production of 207Vac and 415Vac, respectively. Thus, if full motor torque must be developed near base speed (full power) it will be necessary to maintain a rigid incoming line voltage so that adequate motor voltage can be produced. Increasing the incoming voltage by tapping-up the supply transformer, will be advantageous, should rated motor HP be required. However, caution should be used to ensure the input voltage does not increase to damaging levels during periods of low demand such as off-peak and/or weekend hours. Operating a motor at reduced speed (reduced power), or using a motor with a base voltage that is lower than the incoming AC supply rating (ex. 208Vac motor with a 240Vac supply), will also minimize the effect of voltage deprivation. Table 1 incorporates motors rated at 208Vac and 400Vac to help out with the selection process should optimum performance be required with low input voltage. June 14, 2010 Copyright Yaskawa America, INC of 12
5 DC Link Choke, Input Wiring, and Branch Circuit Protection It is important that input wiring and branch circuit protection be selected based on the drive s single-phase input current rating indicated in Table 2. The single-phase input current after derating differs from the three-phase input indicated on the VFD nameplate. Connect the AC single-phase supply to VFD terminals L1(R) and L2 (S) to accommodate models that have cooling fans and soft charge circuits that utilize the AC line supply. The drive s internal AC fan(s) and soft charge contactor are wired to terminals L1 (R) and L2 (S) from the factory. As previously stated, external DC link chokes are required on ALL models that do not have them built-in as standard to limit the DC bus ripple, converter currents, and improve input power factor. Select DC link chokes are based on the information in Table 1. The DC link chokes incorporated in Table1 have been selected to optimize the VFD s output current and HP rating, while minimizing voltage drop. For this same reason, the use of three-phase line reactors is undesirable. The voltage drop associated with three-phase line reactors is significantly larger compared to that of the DC link choke. A large reduction in motor power generation may result when using a three-phase line reactor due to excessive drop in line/bus voltage. If power quality concerns such as line transients and notching dictate a three-phase line reactor must be used, consider using a reduced voltage motor (i.e. a 208V or 400V motor) to reduce the effect of voltage deprivation. Table 3 contains information pertaining to the DC link choke specifications. Physically locate the DC link choke as close to the drive as possible to minimize the wire length. Use terminals +1 and +2 to connect the choke to the drive and remove the factory supplied shorting bar between these terminals prior to connecting the DC link choke. WARNING: The DC link chokes referred to in Table 1 and 3 are open chassis and are designed to be installed within an enclosure. Do not mount DC link chokes directly to any surface without the proper enclosure protection due to high DC bus voltage on power terminals. Failure to do so could result in death or serious injury. VFD Overload Capacity Under single-phase use the DC bus ripple will increase and the minimum bus level will decrease below what is normally generated with three-phase input. For this reason, any overload requirements must be fully identified and understood. The VFD can supply 120% of the drive rated output current indicated in Table 1 for starting purposes (maximum one minute duration under non-repeating conditions). The VFD will not generate overload in excess of 120%, except at low speeds where motor power production remains low. The DC bus voltage may drop beneath critical levels, when load in excess of 120% occurs at higher speeds. Therefore, be sure to select the drive anticipating no more than 120% of motor rated current for starting purposes only. Please consult the factory for additional guidance concerning repeating overloads (cyclic loads) or when overload in excess of 120% is required. Generator Applications When used on generator sets, because of their non-linear load characteristics, many VFDs can induce distortion into the generator output voltage feeding the VFD. Typically, over sizing the generator will be required to prevent the generator from overheating due to increased harmonic currents and lower power factor induced by the VFD. When applying any VFD to a generator, it is recommended that the generator manufacturer be consulted to review the application and system loads to prevent any power issues. June 14, 2010 Copyright Yaskawa America, INC of 12
6 Single-Phase Drive Selection The following tables must be used to ensure proper drive selection for single-phase input applications. Before you begin your selection, make sure you know the motor nameplate data including motor horsepower (HP) and the full load amps (FLA). The chosen drive must meet or exceed both the nameplate motor HP and nameplate motor FLA requirements. Account for any known operating conditions, such as operating the motor into its service factor by using the motor s service factor horsepower and amperage to make your selection. The following tables must be adhered to, because the specifications below are unique to single-phase power system configuration and differ from the standard Yaskawa three-phase VFD specifications. Single-Phase Application Specification Summary Input Voltage: 240/480VAC +10% / -5%, 1 Phase, 60 Hz Drive Single-Phase Ratings must meet or exceed both motor HP and motor FLA (include service factor if applicable) DC Link Chokes must be used on all models below 4022 and 2022 (refer to Table 1 for proper selection) consult factory if DC link chokes cannot be accommodated VFD Output Overload Capacity: 120% of drive rated output current maximum for 60 seconds, non re-occurring (starting motor only) consult factory with cyclic loads or when overload in excess of 120% is required At rated motor HP and 228 VAC (456VAC) single-phase input, maximum motor voltage of 207Vac (415Vac) is to be expected. Recommended motor voltage when optimum performance is required near base speed: 240 VAC Input 208 V motor, 480 VAC input 400 V motor. Use of three-phase line reactors with DC Link chokes is not recommended as the three-phase line reactor will reduce available maximum output voltage that may result in increased motor current. NOTE: When using the Drive with single-phase input power the drive s input phase loss protection must remain enabled. If Input Phase Loss (PF) faults are encountered, be sure to check the load current and incoming voltage levels to ensure both are within specification as outlined in this document. Input phase loss faults generally indicate the drive is undersized for the applied load. Disabling input single-phase protection will result in permanent drive damage and void the warranty. June 14, 2010 Copyright Yaskawa America, INC of 12
7 Model E7/F7/P7 Table 1 Single-Phase Ratings (240V / 60Hz Input) with DC Link Choke Drive Single-Phase Rating Max. Output HP Output Amps Input Amps 208V Motor 230V Motor DC Link Choke HP* Amps* HP* Amps* YEA Part Number Inductance (mh) 20P URX P P P P P P P URX P URX P URX URX URX URX Built-In * Motor HP and Amps values based on NEC 2008 Table with Amp values for 400V motors extrapolated from 460V motor data. WARNING: The DC link chokes referred to in Table 1 are open chassis and are designed to be installed within an enclosure. Do not mount DC link chokes directly to any surface without the proper enclosure protection due to high DC bus voltage on power terminals. Failure to do so could result in death or serious injury. June 14, 2010 Copyright Yaskawa America, INC of 12
8 Model E7/F7/P7 Table 1 Single-Phase Ratings (480V / 60Hz Input) with DC Link Choke Drive Single-Phase Rating Max. Output HP Output Amps Input Amps 400V Motor 460V Motor DC Link Choke HP* Amps* HP* Amps* YEA Part Number Inductance (mh) 40P URX P URX P URX P P P P P P P URX P P P URX URX Built-In * Motor HP and Amps values based on NEC 2008 Table with Amp values for 400V motors extrapolated from 460V motor data. WARNING: The DC link chokes referred to in Table 1 are open chassis and are designed to be installed within an enclosure. Do not mount DC link chokes directly to any surface without the proper enclosure protection due to high DC bus voltage on power terminals. Failure to do so could result in death or serious injury. June 14, 2010 Copyright Yaskawa America, INC of 12
9 Table 2 Wiring and Branch Circuit Recommendations (240V Single-Phase Input) Model Single-Phase 208V Motor 230V Motor Wire Selection* E7/F7/P7 Input Amps HP Amps HP Amps Single Conductor (AWG) Multiple Conductor (AWG) Fuse Selection (Amps) ** Non- Time Time Delay Delay Fuse Fuse (max.) (max.) CB Selection (Amps) Inverse Time Type or MCP Type (max.) 20P P P P P P P AWG x 2P AWG x 2P /0 3 AWG x 2P /0 2 AWG x 2P /0 1/0 x 2P /0 x 2P /0 x 2P x 2P * Wire selection is based on 75 o C Copper Wire per Table 28.1 of UL508A (multiple conductors selected at 80%). ** Refer to NEC 430 when selecting fuses for branch short circuit protection. June 14, 2010 Copyright Yaskawa America, INC of 12
10 Table 2 Wiring and Branch Circuit Recommendations (480V Single-Phase Input) Model Single-Phase 400V Motor 460V Motor Wire Selection* E7/F7/P7 Input Amps HP Amps HP Amps Single Conductor (AWG) Multiple Conductor (AWG) Fuse Selection (Amps) ** Non- Time Time Delay Delay Fuse Fuse (max.) (max.) CB Selection (Amps) Inverse Time Type or MCP Type (max.) 40P P P P P P P P AWG x 2P AWG x 2P AWG x 2P AWG x 2P /0 3 AWG x 2P /0 2 AWG x 2P /0 1/0 x 2P /0 x 2P /0 x 2P x 2P x 2P /0 x 4P * Wire selection is based on 75 o C Copper Wire per Table 28.1 of UL508A (multiple conductors selected at 80%). ** Refer to NEC 430 when selecting fuses for branch short circuit protection. June 14, 2010 Copyright Yaskawa America, INC of 12
11 Drive Selection Example A 240V single-phase submersible pump application incorporates a 7.5 HP, 230Vac pump assembly rated at 20A RMS with a service factor rating of 23A RMS. Determine the proper drive assuming: A) No service factor operation is required B) Service factor operation is required Solution: A) No service factor operation is required: Requirements: 7.5 HP 20 Amps RMS Variable Torque (120% overload is sufficient) Selection: P7U2011 rated 24.2 A RMS and 8.32 HP with DC Link Choke URX B) Service factor operation is required: Requirements: 8.6 HP (7.5 HP 23A/20A) 23 Amps RMS Variable Torque (120% overload is sufficient) Selection: P7U2015 rated 30.8 A RMS and 11.2 HP with DC Link Choke URX Note: Depending on input line voltage level and maximum load HP required, it will be advantageous to consider using a 208Vac pump assembly to ensure adequate HP production for Solution A and Solution B. June 14, 2010 Copyright Yaskawa America, INC of 12
12 DC Link Choke Data for Single-Phase Operation WARNING: The DC link chokes referred to in Table 3 are open chassis and are designed to be installed within an enclosure. Do not mount DC link chokes directly to any surface without the proper enclosure protection due to high DC bus voltage on power terminals. Failure to do so could result in death or serious injury. Table 3 DC Link Choke Dimensions Motor Model DC Link Choke DC Link Choke Dimensions (inches) VAC VAC E7/F7/P7 HP HP YEA Part Inductance Length Depth Height Mtg Hole Mtg Hole Mtg Hole Figure Number (mh) A C B D E Diameter 20P4 - - URX N/A P P x P P x P P x P URX x P URX x P URX x URX x URX x URX x.328 Motor Model DC Link Choke DC Link Choke Dimensions (inches) VAC VAC E7/F7/P7 HP HP YEA Part Inductance Length Depth Height Mtg. Hole Mtg. Hole Mtg. Hole Figure Number (mh) A C B D E Diameter 40P4 - - URX N/A P URX N/A P URX x P P N/A P P x P P x P URX x P P x P x URX x URX x.328 Note: Connect DC link chokes to drive terminals +1 and +2 after removing the factory supplied shorting bar. June 14, 2010 Copyright Yaskawa America, INC of 12
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
Specifying a Variable Frequency Drive s
Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable
Data Bulletin Variable Frequency Drives and Short-Circuit Current Ratings
Data Bulletin Variable Frequency Drives and Short-Circuit Current Ratings 8800DB1203 03/2013 Retain for future use. Introduction Short-circuit current s (SCCRs) for variable frequency drives (VFDs) is
Rotary Phase Converters
FACTS from Ronk Electrical Industries, Inc. Bulletin 11981 Rotary Phase Converters ROTOVERTER Pat. No. 3,670,238 ROTO-CON Pat. No. 4,158,225 What are the ROTO-CON and ROTOVERTER power converters? The ROTO-CON
Line Reactors and AC Drives
Line Reactors and AC Drives Rockwell Automation Mequon Wisconsin Quite often, line and load reactors are installed on AC drives without a solid understanding of why or what the positive and negative consequences
Installation Manual Version 7.3 IMPORTANT:
Installation Manual Version 7.3 IMPORTANT: READ ENTIRE MANUAL CAREFULLY, THIS PHASE CONVERTER MUST BE INSTALLED BY A INDUSTRIAL LICENSED ELECTRICIAN 230 VOLTS MODEL ONLY READ FIRST!!!!!! DANGER: HIGH VOLTAGE
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02
AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5
AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC
Variable Frequency Drives - a Comparison of VSI versus LCI Systems
Variable Frequency Drives - a Comparison of VSI versus LCI Systems Introduction TMEIC is a leader in the innovative design and manufacture of large ac variable f requency drive systems. TMEIC has been
The Facts About Harmonics and Power Factor. Power Quality: Harmonics & Power Factor Correction
The Facts About Harmonics and Power Factor Power Quality: Harmonics & Power Factor Correction 1 Agenda I. Harmonic Basics II. Harmonic Mitigation Methods III. Active Harmonic Filters IV. Applications V.
Product Data Bulletin
Product Data Bulletin Power System Harmonics Causes and Effects of Variable Frequency Drives Relative to the IEEE 519-1992 Standard Raleigh, NC, U.S.A. INTRODUCTION This document describes power system
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
Power System Harmonics
Pacific Gas and Electric Company Power System Harmonics What are power system harmonics? Ideally, voltage and current waveforms are perfect sinusoids. However, because of the increased popularity of electronic
PHASE CONVERSION TECHNOLOGY OVERVIEW
Dr. Larry Meiners, Ph.D. PHASE CONVERSION TECHNOLOGY OVERVIEW Introduction A wide variety of commercial and industrial electrical equipment requires three-phase power. Electric utilities do not install
EET272 Worksheet Week 9
EET272 Worksheet Week 9 answer questions 1-5 in preparation for discussion for the quiz on Monday. Finish the rest of the questions for discussion in class on Wednesday. Question 1 Questions AC s are becoming
32VFD Variable Frequency Drives for Centrifugal Chillers
32VFD 32VFD Variable Frequency Drives for Centrifugal Chillers ENERGY-SAVING CONTROL FOR CENTRIFUGAL CHILLERS Reduce energy consumption in your existing centrifugal chiller Your chiller was specified to
The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY
The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY PowerGate - Cost effective solutions for F 1 Horsepower Rating 001 1-40 HP (208V) 075 1-75 HP (480V) Input Voltage 2V 208-240V 4V 380-480V Disconnect
VARIABLE FREQUENCY DRIVE OPERATION AND APPLICATION OF VARIABLE FREQUENCY DRIVE (VFD) TECHNOLOGY
VARIABLE FREQUENCY DRIVE OPERATION AND APPLICATION OF VARIABLE FREQUENCY DRIVE (VFD) TECHNOLOGY Carrier Corporation Syracuse, New York October 2005 TABLE OF CONTENTS INTRODUCTION..........................2
1321 Power Conditioning Products
Technical Data 1321 Power Conditioning Products Don t Ignore the Cost of Power Line Disturbance Topic Page Product Overview 2 1321-3R, 1321-3RA, and 1321-3RB Series Line Reactors 3 1321 Reflective Wave
HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80
Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...
Harmonic Distortion and Variable Frequency Drives
Harmonic Distortion and Variable Frequency Drives Definitions Variable Frequency Drives (VFDs); sometimes referred to as variable speed drives. Harmonic Distortion is a measure of the amount of deviation
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
RC NETWORKS SALES GUIDE
SALES GUIDE INTRODUCTION TO Recent developments in electronic equipment have shown the following trends: Increasing demands for numerical control machines, robotics and technically advanced appliances
MC1000 Series Installation and Operation Manual
MC1000 Series Installation and Operation Manual NOTE! The manual covers software version M108314 and above. Refer to parameter 63 for the software version of the drive you are working with. If you are
Buck - Boost Transformers
Buck - Boost Transformers Contents Buck - Boost Transformers - Terms & Definitions... 48 Buck - Boost Transformers - Sizing... 50 Quick Reference Chart - 08, 0, 40 Volts Single & Three Phase... 5 Single
VARIABLE FREQUENCY DRIVES Revised 4/30/2015 23 81 07-1 Mechanical Systems
SECTION 23 81 07 - VARIABLE FREQUENCY DRIVES PART 1 - GENERAL 1.1 SUMMARY A. This section includes all variable frequency drives. All standard and optional features shall be included within the VFD panel
ELECTRONIC POWER SYSTEMS
ELECTRONIC POWER SYSTEMS TRADEOFFS BETWEEN SINGLE-PHASE & THREE-PHASE POWER WHITE PAPER: TW0057 1 Executive Summary Modern Electronic Systems are quite often powered from a three-phase power source. While
EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.
EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. A Regal Brand EVERGREEN SOLUTIONS Powered by ECM Technology Upgrade/Replace PSC motors with Evergreen IM Residential/Light Commercial HVAC Systems Reduce
CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING
PART 1-GENERAL 1.01 DESCRIPTION A. This specification is to cover a complete Variable Frequency motor Drive (VFD) consisting of a pulse width modulated (PWM) inverter designed for use on a standard NEMA
GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta
GENERATOR SELECTION Generators must be sized to handle their load based on the continuous KW, kilowatt load, and KVA, kilovoltamp load, and the worst case starting load KW + KVA. They must be derated for
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: [email protected] www.juicegoose.com 06-06 CONGRATULATIONS
UL guidelines, chapter 6.2 / 6.3 Motor Branch Circuits acc. to UL
UL guidelines, chapter 6.2 / 6.3 Motor Branch Circuits acc. to UL Definition of Terms / Explanations Overview of Basic Devices Construction Types acc. to UL 508 Self-Protected Combination Motor Controller
Fundamentals of Inverter Fed Motors
Fundamentals of Inverter Fed Motors Technical Manual 10/02 MN780 Contents Page The Growing Use Of Inverters.................................................................. 1 How Inverters Affect Motors....................................................................
Motor Circuit Protection Tables
NEC Article 40 and Tables Explanation Columns & 2 Motor horsepower ratings are listed in Column. Full load amps from Tables 40.247 through 40.250 are provided in Column 2. Column Various fuse types are
Fronius IG Plus. The next generation grid-connected PV inverter
Fronius IG Plus The next generation grid-connected PV inverter Maximum energy harvest cloudy or clear The first complete inverter solution. Reliable. Proven. Smart. An outstanding addition to the family:
Single Phase Soft Starter
Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS
Braking Resistors for Variable Frequency Drives APPLICATION AC variable frequency drives are commonly used with a general purpose AC induction motor to form a reliable variable speed drive system. For
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The
FREQUENCY CONTROLLED AC MOTOR DRIVE
FREQUENCY CONTROLLED AC MOTOR DRIVE 1.0 Features of Standard AC Motors The squirrel cage induction motor is the electrical motor motor type most widely used in industry. This leading position results mainly
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION
City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION This Appendix A includes technical documents and specifications for the Toshiba 4200 FA 30 kva Uninterruptable Power
Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance
Owner s Manual For Automatic Transfer Switch 100-200 Amp, Service Entrance/Non-Service Entrance Model Numbers RTST100A3 RTSP100A3 RTST150A3 RTST200A3 RTSP200A3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:
ST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C
Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
1000 Hz High Frequency Custom Software
YASKAWA AC Drive - V1000 Option 1000 Hz High Custom Software Supplement Software No. VSV91005X To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance.
12-Volt 10-Amp Regulated Power Supply
22-506.fm Page 1 Friday, August 6, 1999 12:55 PM Cat. No. 22-506 OWNER S MANUAL Please read before using this equipment. 12-Volt 10-Amp Regulated Power Supply 22-506.fm Page 2 Friday, August 6, 1999 12:55
A1000 Cheat Sheet (Open Loop Vector)
A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to
9000X AF Drives. User Manual. May 2011 Supersedes June 2009
9000X AF Drives User Manual May 2011 Supersedes June 2009 9000X AF Drives Disclaimer of Warranties and Limitation of Liability The information, recommendations, descriptions, and safety notations in this
METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D
12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section
Guidelines on the Short Circuit Current Rating for Industrial Control Panels
usa.siemens.com/sccr Guidelines on the Short Circuit Current Rating for Industrial Control Panels Technical Paper for Practical Applications White Paper I October 2014 As per NEC Edition 2014, and UL508A
The full wave rectifier consists of two diodes and a resister as shown in Figure
The Full-Wave Rectifier The full wave rectifier consists of two diodes and a resister as shown in Figure The transformer has a centre-tapped secondary winding. This secondary winding has a lead attached
ABB industrial drives ACS800, drive modules
ABB industrial drives ACS800, drive modules Technical catalog 0.75 to 250 HP @ 240 Vac 2 to 2200 HP @ 480 Vac 5 to 1900 HP @ 600 Vac BUSINESS PROFILE INDUSTRIES PRODUCTS APPLICATIONS EXPERTISE PARTNERS
HVAC Applications. VFD considerations for HVAC systems...
HVAC Applications VFD considerations for HVAC systems... 1 COMMON TERMINOLOGY VFD (VARIABLE FREQUENCY DRIVES) AFC (ADJUSTABLE FREQ. CONTOLLER) ASD (ADJUSTABLE SPEED DRIVES) VSD (VARIABLE SPEED DRIVES)
Automatic Voltage Regulator User s Manual
Resp. dept. R&D We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Copyright
Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 [email protected]
CURRENT TRANSFORMER MODEL J " x 7" PAGE No 2-2 REV 8DEC00 TERMINAL OPTION LEAD WIRE OPTION 8-2 BRASS SCREW TERMINALS (2 PLACES) SEE NOTE 9 6 9 8 6 Ø 2 9 (4 PLACES) UL 05 #6 AWG LEAD WIRE, STANDARD LENGTH
Softstarters Type PSR
Catalog Softstarters Softstarters ABB Softstarters General To the left: A combination with PSR and a manual Motor Starter MS116 Above: PSR16, PSR30 and PSR 45 1 ABB Automation Products serve customers
VLT Series 300 Watt True Sine Wave Inverter
VLT Series 300 Watt True Sine Wave Inverter PURE SINE WAVE INVERTER I ON 0 OFF REMOTE CONTROL AC OUTPUT POWER STATUS Vout Vin Models VLT12-300 VLT24-300 300 Watt VLT Series Inverter - 1 - TABLE OF CONTENTS
PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit
PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives
Harmonics in your electrical system
Harmonics in your electrical system What they are, how they can be harmful, and what to do about them Abstract Harmonic currents, generated by non-linear electronic loads, increase power system heat losses
BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.
SUBMERSIBLE PUMP selection A submersible pump consists of the following basic elements: < Bowl Assembly < Motor < Cable < Drop Pipe < Surface Plate (with)(without) discharge elbow DATA REQUIRED FOR SELECTION
RADIANT PLASMA 4700 Plasma Spark Generator
RADIANT PLASMA 4700 Plasma Spark Generator Installation Guide / User Manual A S P A R K O F F R E S H A I R Aquapulser.com Contents 1 Introduction 2 1.1 About the Product....................................
WHITE PAPER. DC Motors Explained. DC Motors Explained: White Paper, Title Page
DC Motors Explained: White Paper, Title Page DC Motors Explained By Joe Kimbrell, Product Manager, Drives, Motors & Motion, AutomationDirect DC Motors Explained: White Paper, pg. 2 How many types of DC
ABR Brake Rectifier Instruction Manual
ABR Brake Rectifier Instruction Manual Part Number: 552074 Copyright 2012 Magnetek 1. Preface and Safety All rights reserved. This notice applies to all copyrighted materials included with this product,
PSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
Interpreting IEEE Std 519 and Meeting its Harmonic Limits in VFD Applications
Interpreting IEEE Std 519 and Meeting its Harmonic Limits in VFD Applications Copyright Material IEEE Paper No. PCIC-2003-15 Tony Hoevenaars, P. Eng. Kurt LeDoux, P.E. Matt Colosino Member IEEE Member,
98% Efficient Single-Stage AC/DC Converter Topologies
16 POWER CONVERTERS www.teslaco.com 98% Efficient Single-Stage AC/DC Converter Topologies A new Hybrid Switching Method is introduced in this article which for the first time makes possible AC/DC power
VLT Series 3500 Adjustable Frequency Drive Instruction Manual
Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software
Understanding Variable Speed Drives
Understanding Variable Speed Drives April 1, 1997 Solomon S. Turkel, Solomon S. When applied properly, the variable frequency drive (VFD) is the most effective motor controller in the industry today. Modern
Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.
Diode Applications Diode Switching As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off. Voltage Rectifier A voltage rectifier is a circuit that converts an
O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications
Features UniversalACinput/Fulrange Built-inactivePFCfunction Higheficiencyupto91% Protections:Shortcircuit/Overcurent/ Overvoltage/Overtemperature Fanlesdesign,colingbyfreairconvection Colingbyfreairconvection
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings
*** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not
Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter
FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current
IRRIGATION PUMPING Table of Contents - Section 900
IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS
HM-W536 Install Guide
HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
Conext Grid Tie Solar Inverter Conext TX 2800 NA Conext TX 3300 NA Conext TX 3800 NA Conext TX 5000 NA
Conext Grid Tie Solar Inverter Conext TX 2800 NA Conext TX 3300 NA Conext TX 3800 NA Conext TX 5000 NA Owner s Manual www.schneider-electric.com Conext Grid Tie Solar Inverter Owner s Manual www.schneider-electric.com
Current Transformers
Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 Current Transformers Current transformers (CT's) provide
PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?
Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 1) What is a transformer and how does it work? A transformer
Three-Phase Electric Power Distribution for Computer Data Centers
Three-hase Electric ower Distribution for Computer Data Centers WHITE AER E901 Geist January 008 Summary This paper will describe the characteristics of three-phase power and outline the advantages of
Video Camera Installation Guide
Video Camera Installation Guide The intent of this guide is to provide the information needed to complete or modify a video camera installation to avoid lightning and induced power surge damage. This guide
Z1000 HVAC Drive. 3 HP to 500 HP Fan and Pump Applications. Specifications
Z1000 HVAC Drive 3 HP to 500 HP Fan and Pump Applications The Z1000 variable speed drive is designed for building automation applications such as fans, pumps, and cooling towers through 500 HP. The Z1000
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
What Is Regeneration?
What Is Regeneration? Braking / Regeneration Manual Regeneration Overview Revision 1.0 When the rotor of an induction motor turns slower than the speed set by the applied frequency, the motor is transforming
Type SA-1 Generator Differential Relay
ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065 Instruction Leaflet 41-348.11C Effective: November 1999 Supersedes I.L. 41-348.11B, Dated August 1986 ( ) Denotes
Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager
Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager Introduction There is a growing trend in the UPS industry to create a highly efficient, more lightweight and smaller UPS
WIND TURBINE TECHNOLOGY
Module 2.2-2 WIND TURBINE TECHNOLOGY Electrical System Gerhard J. Gerdes Workshop on Renewable Energies November 14-25, 2005 Nadi, Republic of the Fiji Islands Contents Module 2.2 Types of generator systems
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles
AC Induction Motors Simplest and most rugged electric motor Consists of wound stator and rotor assembly AC in the primary member (stator) induces current in the secondary member (rotor) Combined electromagnetic
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
Installation & Operation Manual Dial-A-Flow Adjustable Frequency Drives
GM 04-13 Installation & Operation Manual Dial-A-Flow Adjustable Frequency Drives for 1/8 HP thru 1HP 3-Phase AC Motors rated 208 230 VAC, 50 & 60 Hz NEMA-1 / IP-40 Operates from 115 and 208/230 Volt 50/60
Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity
Proper Application of 415V Systems in North American Data Centers A White Paper from the Experts in Business-Critical Continuity Introduction Increasing pressure to reduce operating expenses and be more
50Hz SUBMERSIBLE MOTORS APPLICATION INSTALLATION MAINTENANCE
50Hz SUBMERSIBLE MOTORS APPLICATION INSTALLATION MAINTENANCE Commitment To Quality Franklin Electric is committed to provide customers with defect free products through our program of continuous improvement.
Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008
Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be
Power Quality Issues, Impacts, and Mitigation for Industrial Customers
Power Quality Issues, Impacts, and Mitigation for Industrial Customers By Kevin Olikara, Power and Energy Management Products Rockwell Automation, Inc. Now, more than ever, electronic equipment and computing
