High-density modular data center making cloud easier. Frank Zheng Huawei

Size: px
Start display at page:

Download "High-density modular data center making cloud easier. Frank Zheng Huawei"

Transcription

1 High-density modular data center making cloud easier Frank Zheng Huawei

2 Content Cloud s impact to data center Concerns of DC construction 4S DC making cloud easier Success stories

3 Cloud? Layman s view to Cloud: Complicated techniques Big business with large opportunities Resources sharing, on-demand use Intelligent High density Flexible High efficiency

4 Cloud s impacts to DCPI Operation manage Resource manage IT utilization works in 10-80% DC power consumption increases in times, that requires DCPI to be adjustable, especially the cooling system Cloud virtualization lead to more complex operation, requires intelligent operation DCPI should be aligned with business and IT which realized intelligent configuration Intelligent Flexible 10-80% IT utilization changes widely Huawei E6000 High density High efficiency Rapid upgrade of chips integration reduce the size of IT equipment Blades and rack type of servers deployed widely,10kw/rack becomes normal Resource constraints to centralized data centers High power consumption, and low carbon becomes the focus Lower OPEX to improve competitiveness

5 Content Cloud s impact to data center Concerns of DC construction 4S DC making cloud easier Success stories

6 Traditional data center challenged by Cloud Data center hard to meet cloud s requirements Long construction period Lack of flexibility Poor management Low efficiency 2 yrs average period of construction 2.5~3 PUE of traditional DC 120day Average commission time Load IT Load IT Load IT Load Load IT Load 5 8hr Site inspection/alarm Manual inspections 30% Average IT resource utilization 1/3 energy wasted!

7 Data center trends 1: high density, modular High density design, adapt to 7-30kW/rack, satisfy blade/rack servers deployment an ddynamic power consumption 14kW /cabinet 45kW/cabinet Modularization realizes on-demand deployment, avoid over investment

8 Trends 2: Green with lower PUE TDC modular Optimized floor Cold aisle contain High efficiency UPS High utilization rate Row Cooling Hot aisle containment Free cooling Intelligent management PUE (Power Usage Effectiveness) invented by Green Grid used to evaluate DC efficiency, now DC with PUE<1.6 considered high efficiency PUE = Total power usage of DC / IT power usage, lower PUE means high power utilization rate=more racks to be deployed =more income

9 Trends 3: Standardization and Prefabrication standardization Standardized design of core components Standardized design of system interface Simplification Components are prefabricated, assembled, and tested in factories to ensure project quality and reduce onsite work Construction period of a traditional DC: 450 days "I need greater capacity." To be evaluated Customizing auxiliary components, applications, and services "I have greater capacity." Running Design for one to two months Engineering design for three to four months Trial running for half a month to one month Eight to ten weeks Eight to ten weeks Four to six weeks One to two weeks Less than or equal to one week Constructing for seven to eigth months Planning and design Signing orders Finishing goods preparation Finishing transportation Finishing installation and commissioning Finishing acceptance

10 Trends 4: Intelligent management Uniformed management of DCPI Monitors infrastructures such as power supply, cooling, and fire control in the DC in real time. Uniformly manages, plans, and analyzes assets, capacity, and operation in the DC. Intelligently and automatically checks and outputs running data of the DC. Manpower saving 60% 3D view Integrated management system Monitoring center Unified management Interworking management Uniform monitor Information sharing Improve efficiency Reduce manpower NetE co CAPEX 15% OPEX 25% Interworking with the business Intelligently interworks with the up level-it system, automatically deals with incidents, and improves availability of the DC. Interworks with the upper service business level, properly schedules and distributes resources, and ensures safe and efficient service running. BMS 建 筑 设 备 监 控 Lighting Monitor Elec-system Network Security Firing Independent system Distributed 分 散 control 控 制 Separated failure Intelligent management improves the data center availability, increase efficiency, reduce OPEX and easy maintenance.

11 Content Cloud s impact to data center Concerns of DC construction 4S DC making cloud easier Success stories

12 Huawei 4S new generation DC Simple Scalable Smart Saving DCIM:NetEco Standard design Pre-engineering, easy site assemble Less site limits Modular design On-demand deployment Hybrid power density, high density and low density Unified monitor and manage Linked to business level Professional DCPIM OPEX saving 30% Construction times 50% DC utilization rate 30%

13 Huawei IDS (Intelligent DC Solution) IDS for full range cases 1. Fast deployment 2. On-demand construction 3. High density 4. Emergency and disaster redundancy 5. On-demand construction 1. Modular deploy with power density 2. Fast deployment 3. On-demand construction 4. On-demand construction 5. Wide range of IT capacity 1. Integrated and unified management 2. Green 3. High availability Container Modular Intelligent-building DC

14 Huawei DC solution overview CAD:Consult, Architecture & Design 5 Different Solutions V1 CCDC :Cluster Container DC V2 ICDC: Integrated Container DC IDS1000 container DC V1 LARGE DC V2 SMALL DC IDS2000 modular DC V3 MINI DC Diesel generator, high voltage power supply, chillers Engineering products 3 Core Products UPS UPS&PDU PDU Air Cooled Water Cooled Precision Air Conditioner Software Platform + Hardware NetEco Management System 4 Platform Techs Flexible Structure Predictable Cooling Intelligent Management High Efficiency Power Supply

15 服 务 1 ( 带 宽 ) 产 品 (IDC) 服 务 2 (IP 地 址 使 用 ) 服 务 n ( 安 全 服 务 ) 产 品 类 型 服 务 种 类 服 务 级 别 Huawei DC all levels full solution overview Consulting and Plan Professional consulting service Market, competition, and customer analysis Business analysis, plan, and operation suggestions Work plan and development suggestions consultation& design CFD emulation diagnose analyzing &evaluation DC location selecting &design L4: operation management support platform Resources management Network management Business management Operation management L3:Business Bandwidth renting Hosting Host renting L2:IT Equipment Network L1: Data center Power Supply Cabling In-depth design and implementation, and customization Security Room &device location renting Domain name registration Calculate Cooling System Enterprise post office Virtual host VPS Surge protection& grounding Storage Firewall Rack system Fire control system Anti-DDos and anti-virus Online storage & backup IDS 消 防 系 统 Management 云 业 务 Elastic host Virtual desktop Cloud computing Cloud storage E2E virtualization Inner decoration Delivery and Maintenance Integrated service mode Truss advices, cooperative mode Tabulation, performance analyzing Lifecycle, purchase management Performance of operation &maintenance, accident analyzing Maintenance, operation testing, security guaranty

16 Content Cloud s impact to data center Concerns of DC construction 4S DC making cloud easier Success stories

17 Huawei K3 Container Data Center Original Data center unable to support the company s business which is in rapid continuous expansion, new DC required to support 20,000 VDI and employees daily work. When the cloud market is booming, Huawei wishes success cases to drive the market. IT system facing challenges: Complicated IT environment, un-continuous service, blocked information; Short life (3-5 years) of traditional PC brings large cost; Power consumption of single PC upto 200W, low efficiency and high maintenance cost; Information security problem; High failure rate of PC, local hardware/operation system/software failure may cause business interruption; Complicated and difficult maintenance to permissions, software, security of many independent business systems.

18 Huawei K3 Container Data Center Scale:20,000 VDI (10,000 for 1 st phase), 500kW IT nominal capacity (250kW for 1 st phase), power supply: 1,600 kva Availability level:tier4 (Dual power, kW DG, 2N UPS, 2N cooling system configuration) IT configuration::56 baskets of E6000, 168 units storage, 4 network racks, double in future. Area:980m 2 for 1 st phase (L56m*W17.5m), including reserving zone 1680m 2 (L96m*W17.5m) Highlight:Outdoor deployment, with reinforced concrete based installation; Modular architecture ( 5000 virtual desktop/module, 2 modules for 1 st phase and 4 modules for future; Mid-high power density (>7kW/rack), designed PUE = 1.4.

19 Huawei K3 Container Data Center view

20 Huawei K3 Container Data Center view

21 Huawei K3 Container Data Center view Control IT Power

22 Huawei K3 Container Data Center view control power IT-cold aisle IT-hot container

23 Huawei K3 Container DC technique points Advanced IT hardware Cloud management architecture Chilled water cooling system High density row cooling Container modular deployment High efficiency UPS Intelligent management system

24 Huawei VDI values to customer Container DC takes green safety cloud desktop Improve working efficiency Higher reliability 99.5% % Down time 21hrs 7.1hrs DC reliability and SLA for business DC IT power reduced 50% Desktop cloud Lower CAPEX and OPEX Information safety Green and healthy working environment

25 Huawei container data center-ids1000 Modularized subsystem Container DC takes green safety cloud desktop Mid-high density, modular DC for large company, operators Cluster Consists of IT, power, cooling container Single or cluster deployment 20 or 40 ft standard container Low density, low cost, small DC for SME Modularized System All in one One container integrates all sub-systems 20 or 40 ft standard container

26 Huawei container DC values to customer High density, availability Max 30kW/rack End to end All in One or cluster 400kW/container T2-4 flexible Green, low TCO CAPEX save 20% Only network, power and water connection required All system integrated PUE to1.25 Saving energy 30% High efficiency, flexible cooling system IDS1000 Fast and easy 10 weeks manufacture 1 week installation Easy replication 1 5 Environment friendly -40 ~55 Closed water system, for dry area

27 Shanghai Telecom Zhoujiadu IDC Background Shanghai Telecom Zhoujiadu station located nearby the World EXPO China Pavilion, which made great contributions to the World. After the EXPO, the telecom station chosen as pilot project for cloud computing. Customer needs New deployment to breakthrough the power density limits of 7kW/rack Green and saving, PUE less than 1.6 HVDC, In-Row cooling techniques etc. Intelligent management, real time PUE display, reduce site maintenance manpower

28 Shanghai Telecom Zhoujiadu IDC 3 modules, 180kW/module Each module: 2 630A DC PDF 24 IT racks 8 air cooled in-row A/C Intelligent management Rack top wiring 300mm raised floor (A/C pipes fit underfloor) Core points: Prefabricated modules: Easy fast site deployment; HVDC 6 units 240V/630A DC PDF; In-Row cooling:meets power density of 9kW/rack; Cold aisle contain: PUE<1.6 Intelligent management

29 Shanghai Telecom Zhoujiadu IDC 3 modules Between modules (hot aisle) Module inside (cold aisle)

30 Shanghai Telecom Zhoujiadu IDC

31 HD modular DC, making easier cloud Container Modular

32 Thanks!

Huawei Data Center Facility Integration Solution

Huawei Data Center Facility Integration Solution Huawei Data Center Facility Integration Solution HUAWEI TECHNOLOGIES CO., LTD. As the growing demand for efficiency, flexibility and low-cost, enterprise need a more flexible and efficient data center

More information

Huawei IDS1000 Container Data Center Solution

Huawei IDS1000 Container Data Center Solution CloudPower Huawei IDS1000 Container Data Center Solution HUAWEI TECHNOLOGIES CO., LTD. Traditional data centers suffer from long construction periods, high energy consumption and high initial investment,

More information

Fast Deployment, Dynamic Expansion, Green

Fast Deployment, Dynamic Expansion, Green Fast Deployment, Dynamic Expansion, Green ZTE Mobility Modular Data Center (M2DC) Overview Based on current rapid growth business needs of the global data centers, and the special needs of some of the

More information

IPSIP M series-m Modular Data Center

IPSIP M series-m Modular Data Center IPSIP M series-m Modular Data Center IPSIP MODULAR TECHNOLOGIES. 1 With the rapid development of cloud computing and mobile Internet businesses, the growth of IT density and energy consumption are bringing

More information

Huawei IDS2000 Modular Data Center Solution

Huawei IDS2000 Modular Data Center Solution CloudPower Huawei IDS2000 Modular Data Center Solution HUAWEI TECHNOLOGIES CO., LTD. With the rapid development of cloud computing and mobile Internet businesses, the growth of IT density and energy consumption

More information

All-in-one Container Data Center solution HUAWEI TECHNOLOGIES CO., LTD.

All-in-one Container Data Center solution HUAWEI TECHNOLOGIES CO., LTD. All-in-one Container Data Center solution Contents All-in-one : Integrated one-stop data center solution All-in-one configuration and subsystems introduction Application scenarios and successful stories

More information

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert Data Center Consolidation Trends & Solutions Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert Agenda Traditional Data Centers Drivers of a Changing Environment Alternate

More information

Huawei Cloud and Virtualization introduction HUAWEI TECHNOLOGIES CO., LTD.

Huawei Cloud and Virtualization introduction HUAWEI TECHNOLOGIES CO., LTD. Huawei Cloud and Virtualization introduction HUAWEI TECHNOLOGIES CO., LTD. Lode pokladu admirala Zheng He Huawei Desktop Cloud E2E Solution Architecture Cloud Network Terminal Desktop managemen t FusionAccess

More information

How To Power And Cool A Data Center

How To Power And Cool A Data Center Architecting the Green Data Center Viktor Hagen Field Business Development Data Center & High Performance Computing 1 Where we are Today Environmental sustainability is a major global trend for the 21st

More information

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design. Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design. Equinix Telecity Kvastvägen 25-29 128 62 Sköndal Stockholm Sweden Tel: +46 (0) 8 799 3800 se.info@telecity.com www.telecitygroup.se

More information

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity SmartDesign Intelligent, Integrated Infrastructure For The Data Center Solutions For Business-Critical Continuity Prepare Your Data Center For What s Next Efficiency. Availability. Capacity. Control. One

More information

Building a data center. C R Srinivasan Tata Communications

Building a data center. C R Srinivasan Tata Communications Building a data center C R Srinivasan Tata Communications Introduction Data Center as defined by TIA 942 A building or a portion of a building whose primary function is to house a computer room and its

More information

AIRAH Presentation April 30 th 2014

AIRAH Presentation April 30 th 2014 Data Centre Cooling Strategies The Changing Landscape.. AIRAH Presentation April 30 th 2014 More Connections. More Devices. High Expectations 2 State of the Data Center, Emerson Network Power Redefining

More information

Enterprise Data Centres

Enterprise Data Centres Enterprise Data Centres 09/12/2014 MAR0064 Cannon Data Campus s Pre-Engineered, factory built modules and systems combine to produce a high performance, efficient, Data Centre Campus. s White Space, Mechanical

More information

Enabling an agile Data Centre in a (Fr)agile market

Enabling an agile Data Centre in a (Fr)agile market Enabling an agile Data Centre in a (Fr)agile market Phil Dodsworth Director, Data Centre Solutions 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without

More information

opdc Cut your data center OPEX upto 70%

opdc Cut your data center OPEX upto 70% opdc Cut your data center OPEX upto 70% Advantages Configuration Introducing the plug & play On Premises Data Center Introducing - The plug & play on premises data center The is a self-contained data center

More information

The Enterprise Journey to a Cloud based Data Centre

The Enterprise Journey to a Cloud based Data Centre Security Level: The Enterprise Journey to a Cloud based Data Centre www.huawei.com Author/ Email: Neo Teck Guan/ teckguan.neo@huawei.com Version: V1.0 (20131113) HUAWEI TECHNOLOGIES CO., LTD. Content 1.

More information

Convergence of Complexity

Convergence of Complexity Convergence of Complexity Optimize Existing Data Center Space Measure And Allocate Energy Cost Plan for new data centers or additional capacity How to make your Data Center Last Longer, Gartner, December

More information

POD S in Data Centres. The Frame Group Pty Ltd

POD S in Data Centres. The Frame Group Pty Ltd Presented by: Greg Goode The Frame Group Pty Ltd DATA Centres? POD SOLUTIONS REFERRED TO AS: Cells Modular Rooms High Density Zones Portable Modular Data Centres (Containers) Multiple Interpretations Varied

More information

Scalable. Affordable. Flexible. Fast.

Scalable. Affordable. Flexible. Fast. Modular Data Center Solutions Scalable. Affordable. Flexible. Fast. Build the data center you need today with the flexibility to meet tomorrow s challenges The only constant in business is change. Fluctuations

More information

Green Data Centre Design

Green Data Centre Design Green Data Centre Design A Holistic Approach Stantec Consulting Ltd. Aleks Milojkovic, P.Eng., RCDD, LEED AP Tommy Chiu, EIT, RCDD, LEED AP STANDARDS ENERGY EQUIPMENT MATERIALS EXAMPLES CONCLUSION STANDARDS

More information

IBM Portable Modular Data Center Overview for Critical Facilities Round Table

IBM Portable Modular Data Center Overview for Critical Facilities Round Table Brian Canney Global Services Executive, IBM GTS Site and Facilities Services April 2011 IBM Portable Modular Data Center Overview for Critical Facilities Round Table 2009 IBM Corporation Key messages Containers

More information

THE WORLD S MOST EFFICIENT DATA CENTER

THE WORLD S MOST EFFICIENT DATA CENTER THE WORLD S MOST EFFICIENT DATA CENTER HP POD 240a Ed Turkel Manager, WW HPC Marketing Hyperscale Business Unit 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

ICT and the Green Data Centre

ICT and the Green Data Centre ICT and the Green Data Centre Scott McConnell Sales Manager c/o Tanya Duncan MD Interxion Ireland Green Data Centres Our Responsibility Data centre greenhouse gas emissions are projected to quadruple by

More information

VISIT 2010 Fujitsu Forum Europe 0

VISIT 2010 Fujitsu Forum Europe 0 VISIT 2010 Fujitsu Forum Europe 0 Virtualization & Automation Room 13a Shaping tomorrow with you. Green Data Center Services Martin Provoost Director, Data Centers and Networks, Fujitsu UK & Ireland 14:00

More information

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009 Optimum Climate Control For Datacenter - Case Study T. Prabu March 17 th 2009 Agenda 2 About EDEC (Emerson) Facility Data Center Details Design Considerations & Challenges Layout Design CFD Analysis Of

More information

Data Center Solutions - The Containerized Evolution

Data Center Solutions - The Containerized Evolution Data Center Solutions - The Containerized Evolution Power IT Cooling 7 th Green Connected World Tsikogias Thanassis Data Centers Solutions Architect, IT Business Athens 2015 1 We are the global specialist

More information

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions Data Centre Solutions... energy efficient by design APC by Schneider Electric Elite Data Centre Partner APC s leading Elite Data Centre Solutions Partner providing customers with expert advice, integration

More information

The Pros and Cons of Modular Systems

The Pros and Cons of Modular Systems The Pros and Cons of Modular Systems Kevin Brown, Vice President Global Data Center Offer Schneider Electric Schneider Electric 1 Foundational BUSINESS OVERVIEW Rev 2 Desired characteristics of pre-fabricated

More information

FEAR Model - Review Cell Module Block

FEAR Model - Review Cell Module Block F.E.A.R. Returns: 5 Steps Toward Data Center Efficiency Today Objectives Benefits for ITS professionals Brief review of the FEAR data center Define data center efficiency Link efficiency to the FEAR data

More information

DATA CENTER ASSESSMENT SERVICES

DATA CENTER ASSESSMENT SERVICES DATA CENTER ASSESSMENT SERVICES ig2 Group Inc. is a Data Center Science Company which provides solutions that can help organizations automatically optimize their Data Center performance, from assets to

More information

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009 Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009 Agenda Overview - Network Critical Physical Infrastructure Cooling issues in the Server Room

More information

Automation's Modular Containerized Datacenter Solutions

Automation's Modular Containerized Datacenter Solutions SAFE Automation's Modular Containerized Datacenter Solutions Automation's SAFE (Secure, Autonomous, Flexible, Efficient) Modular Containerized Datacenter offers a fast, flexible and efficient solution

More information

IBM Twin Data Center Complex Ehningen Peter John IBM BS peter.john@de.ibm.com. 2011 IBM Corporation

IBM Twin Data Center Complex Ehningen Peter John IBM BS peter.john@de.ibm.com. 2011 IBM Corporation IBM Twin Data Center Complex Ehningen Peter John IBM BS peter.john@de.ibm.com Overview Profile IBM owned facility 6447 m² IT-Space Infrastructure concurrent maintainable (Tier Level 3) Feed-ins of Power

More information

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Overview of Green Energy Strategies and Techniques for Modern Data Centers Overview of Green Energy Strategies and Techniques for Modern Data Centers Introduction Data centers ensure the operation of critical business IT equipment including servers, networking and storage devices.

More information

Data Center Technology: Physical Infrastructure

Data Center Technology: Physical Infrastructure Data Center Technology: Physical Infrastructure IT Trends Affecting New Technologies and Energy Efficiency Imperatives in the Data Center Hisham Elzahhar Regional Enterprise & System Manager, Schneider

More information

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while

More information

Design Best Practices for Data Centers

Design Best Practices for Data Centers Tuesday, 22 September 2009 Design Best Practices for Data Centers Written by Mark Welte Tuesday, 22 September 2009 The data center industry is going through revolutionary changes, due to changing market

More information

HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution

HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution Group Data Center Concept: big center, small branch With the development and maturity of the IT automation age, rapid development

More information

Data Center Facility Basics

Data Center Facility Basics Data Center Facility Basics Ofer Lior, Spring 2015 Challenges in Modern Data Centers Management, Spring 2015 1 Information provided in these slides is for educational purposes only Challenges in Modern

More information

As close to perfection. development and production. Modular data center

As close to perfection. development and production. Modular data center As close to perfection development and production Modular data center August 2014 What is GreenMDC modular data center? Basically it is the modular design construction which is realized by the principle

More information

Questions to be responded to by the firm submitting the application. Why do you think this project should receive an award? How does it demonstrate:

Questions to be responded to by the firm submitting the application. Why do you think this project should receive an award? How does it demonstrate: Questions to be responded to by the firm submitting the application Why do you think this project should receive an award? How does it demonstrate: innovation, quality, and professional excellence transparency

More information

abstract about the GREEn GRiD

abstract about the GREEn GRiD Guidelines for Energy-Efficient Datacenters february 16, 2007 white paper 1 Abstract In this paper, The Green Grid provides a framework for improving the energy efficiency of both new and existing datacenters.

More information

Infrastructure as a Service

Infrastructure as a Service Infrastructure as a Service Next Generation Data Center & Cloud Paul Chen paul.chen@cskytech.com 2013 Csky Information All rights reserved. Changing More Users More Devices More Data >1 Billion More Netizen

More information

Colocation Selection Guide. Workspace Technology Ltd

Colocation Selection Guide. Workspace Technology Ltd Colocation Selection Guide Workspace Technology Ltd Technology House 5 Emmanuel Court Reddicroft Sutton Coldfield West Midlands B72 1TJ Tel 0121 354 4894 Fax 0121 354 6447 www.workspace-technology.com

More information

S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015

S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015 S c h n e i d e r E l e c t r i c BUSINESS IMPACT Datacenter means business - create the bridge between IT en Facilities. Jack Hack Enterprise System Engineer 19 November 2015 1 Your ability to compete

More information

Managing Cooling Capacity & Redundancy In Data Centers Today

Managing Cooling Capacity & Redundancy In Data Centers Today Managing Cooling Capacity & Redundancy In Data Centers Today About AdaptivCOOL 15+ Years Thermal & Airflow Expertise Global Presence U.S., India, Japan, China Standards & Compliances: ISO 9001:2008 RoHS

More information

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Reference Guide: SmartDesign Approach: Common Data Center Challenges: Smart Solutions Reference Guide Solutions For Business-Critical Continuity 1100kW Tier 3 With High Density Design Intelligent, Integrated Infrastructure for the Data Center Reference Guide: 1100kW Tier

More information

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers CURBING THE COST OF DATA CENTER COOLING Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers OVERVIEW Compare Cooling Strategies in Free- Standing and In-Building

More information

How To Build An Hpl Data Center

How To Build An Hpl Data Center Delivering the data center of the future Eva Beck Business Development Manager SCI EMEA 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice

More information

The Efficient Enterprise. Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric

The Efficient Enterprise. Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric Ee The Efficient Enterprise Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric Keystrokes Kilowatts Heat OUT Electricity IN Need for bandwidth exploding Going hyperbolic! 30,000

More information

Data Center Equipment Power Trends

Data Center Equipment Power Trends Green field data center design 11 Jan 2010 by Shlomo Novotny Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp. explores water cooling for maximum efficiency - Part 1 Overview Data

More information

Building a Real Data Center During the Great Recession

Building a Real Data Center During the Great Recession Building a Real Data Center During the Great Recession Steven Carlini Sr Director, Data Center Global Solution Offer Management APC by Schneider Electric Schneider Electric at a glance global, innovative

More information

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management. AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled

More information

Introduction to Hitachi Group Environment- conscious Data Center Programme for inspiring change

Introduction to Hitachi Group Environment- conscious Data Center Programme for inspiring change Introduction to Hitachi Group Environment- conscious Data Center Programme for inspiring change DATA CENTRE LOCATIONS Forum Kouvola, Finland Hitachi in Europe September 2011 By Ian Blond Head of Data Centre

More information

Direct Contact Liquid Cooling (DCLC ) PRODUCT GUIDE. Industry leading data center solutions for HPC, Cloud and Enterprise markets.

Direct Contact Liquid Cooling (DCLC ) PRODUCT GUIDE. Industry leading data center solutions for HPC, Cloud and Enterprise markets. Direct Contact Liquid Cooling (DCLC ) PRODUCT GUIDE Industry leading data center solutions for HPC, Cloud and Enterprise markets. Leadership, Collaboration & Expertise CooIIT Systems Innovates and Delivers

More information

Introduction to IT Infrastructure Components and Their Operation. Balázs Kuti

Introduction to IT Infrastructure Components and Their Operation. Balázs Kuti Introduction to IT Infrastructure Components and Their Operation Balázs Kuti Agenda Challenges faced by enterprises today, scale of the IT plant Diversity of an IT plant Key Server Infrastructure Components

More information

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling Joshua Grimshaw Director of Engineering, Nova Corporation

More information

Re Engineering to a "Green" Data Center, with Measurable ROI

Re Engineering to a Green Data Center, with Measurable ROI Re Engineering to a "Green" Data Center, with Measurable ROI Alan Mamane CEO and Founder Agenda Data Center Energy Trends Benchmarking Efficiency Systematic Approach to Improve Energy Efficiency Best Practices

More information

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED. Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED. Presentation Goals & Outline Power Density Where we have been- where we are now - where we are going Limitations of Air Cooling

More information

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power and cooling savings through the use of Intel

More information

Reducing Data Center Energy Consumption

Reducing Data Center Energy Consumption Reducing Data Center Energy Consumption By John Judge, Member ASHRAE; Jack Pouchet, Anand Ekbote, and Sachin Dixit Rising data center energy consumption and increasing energy costs have combined to elevate

More information

Solve your IT energy crisis WITH An energy SMArT SoluTIon FroM Dell

Solve your IT energy crisis WITH An energy SMArT SoluTIon FroM Dell Solve your IT energy crisis WITH AN ENERGY SMART SOLUTION FROM DELL overcome DATA center energy challenges IT managers share a common and pressing problem: how to reduce energy consumption and cost without

More information

How to build your Data Center Digitice roadshow Vaasa 3.12.2015

How to build your Data Center Digitice roadshow Vaasa 3.12.2015 How to build your Data Center Digitice roadshow Vaasa 3.12.2015 Mikko Aho Sales Director 044 593 4698 1 A Strong Family The Friedhelm Loh Group a successful business 11.500 employees worldwide 78 int.

More information

The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space.

The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space. The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space. Terminology: Telco: Dmarc: NOC: SAN: GENSET: Switch: Blade

More information

The art of the possible.

The art of the possible. IBM Scalable Modular Data Center The art of the possible. Rapidly deploying cost-effective, energy-efficient data centers APC InfraStruXure Rapidly deploying cost-effective, energy-efficient data centers

More information

Presented at Computing in High Energy & Nuclear Physics

Presented at Computing in High Energy & Nuclear Physics Presented at Computing in High Energy & Nuclear Physics CHEP - Prague, Czech Republic March 25, 2009 Dean Nelson Sr. Director, Global Lab & Datacenter Design Services (GDS) 1 Density is King - Moore s

More information

IMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT

IMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT DATA CENTER RESOURCES WHITE PAPER IMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT BY: STEVE HAMBRUCH EXECUTIVE SUMMARY Data centers have experienced explosive growth in the last decade.

More information

Data Center Components Overview

Data Center Components Overview Data Center Components Overview Power Power Outside Transformer Takes grid power and transforms it from 113KV to 480V Utility (grid) power Supply of high voltage power to the Data Center Electrical Room

More information

Elements of Energy Efficiency in Data Centre Cooling Architecture

Elements of Energy Efficiency in Data Centre Cooling Architecture Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total

More information

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits. This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits. DCD, DCOM, DCE DESIGN IMPLEMENTATION BEST PRACTICE OPERATION & MANAGEMENT DATA

More information

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management. AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled

More information

Virtual Machine in Data Center Switches Huawei Virtual System

Virtual Machine in Data Center Switches Huawei Virtual System Virtual Machine in Data Center Switches Huawei Virtual System Contents 1 Introduction... 3 2 VS: From the Aspect of Virtualization Technology... 3 3 VS: From the Aspect of Market Driving... 4 4 VS: From

More information

Data Centre Basiglio, Milan Flexible, advanced and efficient by design.

Data Centre Basiglio, Milan Flexible, advanced and efficient by design. Data Centre Basiglio, Milan Flexible, advanced and efficient by design. TelecityGroup Via Francesco Sforza 13 Milano 3 City 20080 Basiglio MI Italy Tel: +39 02 36679500 it.info@telecity.com www.telecitygroup.it

More information

SMART SHELTER CONTAINER

SMART SHELTER CONTAINER Da ta Ce nt er Total Flexibility and Security in a Modular Data Center Advantages Environmentally Friendly Short Delivery Time Smart Shelter Container (SSC) solution provides a fully functional Data Center

More information

CUSTOMER EXPERIENCE CENTER

CUSTOMER EXPERIENCE CENTER v CUSTOMER EXPERIENCE CENTER ABOUT THE CUSTOMER EXPERIENCE CENTER MAKE YOUR DATA CENTER AS DYNAMIC AS YOUR BUSINESS Emerson Network Power continuously strives to provide the best solutions by working collaboratively

More information

Datacentre Reading East 2 Data sheet

Datacentre Reading East 2 Data sheet Datacentre Reading East 2 Data sheet Data sheet Datacentre Reading East 2 Find us With 10 datacentres, over 4,500 racks and a 10Gb resilient core network between our datacentre locations, Pulsant has the

More information

A Blueprint for a Smarter Data Center Data Center Services helps you respond to change

A Blueprint for a Smarter Data Center Data Center Services helps you respond to change Bret W. Lehman, PE GTS Site and Facilities Services March 25, 2011 A Blueprint for a Smarter Data Center Data Center Services helps you respond to change 2011 IBM Corporation Change is accelerating IT

More information

Huawei: Soluciones para Empresas

Huawei: Soluciones para Empresas Security Level: Huawei: Soluciones para Empresas www.huawei.com Joan Vila Enterprise IP Solutions Manager Joan.Vila@huawei.com Contents Huawei Corporation Huawei Solution Highlights A Global Company with

More information

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity Modular architecture for high power UPS systems A White Paper from the experts in Business-Critical Continuity Abstract Today, more than ever before, energy efficiency and cost-savings are among the top

More information

GRNET Cloud Center economics and Green IT case studies

GRNET Cloud Center economics and Green IT case studies GRNET Cloud Center economics and Green IT case studies Anastasios Zafeiropoulos (tzafeir@grnet.gr) Greek Research & Technology Network Outline Driving forces for Green IT GRNET Data Centers Deployment

More information

EXAMPLE OF A DATA CENTRE BUILD

EXAMPLE OF A DATA CENTRE BUILD EXAMPLE OF A DATA CENTRE BUILD BT Harmondsworth Data Centre Hall 2 Upgrade Temperature Control have been involved in providing specialist to data centres for over 20 years, starting from providing specialist

More information

Data Center Infrastructure Management: ERP for the Data Center Manager

Data Center Infrastructure Management: ERP for the Data Center Manager Data Center Infrastructure Management: ERP for the Data Center Manager 1 2 Topics What s DCIM & the ERP Analogy Why DCIM How DCIM Works How DCIM Helps 3 DCIM by Definition DCIM is a system that collects

More information

Business Case for Data Center Network Consolidation

Business Case for Data Center Network Consolidation Business Case for Data Center Network Consolidation Executive Summary Innovations in cloud, big data, and mobility as well as users expectations for anywhere, anytime, and any device access are defining

More information

COLOCATION A BUYERS GUIDE

COLOCATION A BUYERS GUIDE COLOCATION A BUYERS GUIDE INTRODUCTION Colocation in a data centre offers organisations a place to securely house their IT equipment, as opposed to storing and running it on-site, which can be both expensive

More information

How To Run A Data Center Efficiently

How To Run A Data Center Efficiently A White Paper from the Experts in Business-Critical Continuity TM Data Center Cooling Assessments What They Can Do for You Executive Summary Managing data centers and IT facilities is becoming increasingly

More information

Managing Data Centre Heat Issues

Managing Data Centre Heat Issues Managing Data Centre Heat Issues Victor Banuelos Field Applications Engineer Chatsworth Products, Inc. 2010 Managing Data Centre Heat Issues Thermal trends in the data centre Hot Aisle / Cold Aisle design

More information

Huawei Smart Education Solution

Huawei Smart Education Solution Copyright Huawei Technologies Co., Ltd. 2013. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies

More information

Pursuing Operational Excellence. Better Data Center Management Through the Use of Metrics

Pursuing Operational Excellence. Better Data Center Management Through the Use of Metrics Pursuing Operational Excellence Better Data Center Management Through the Use of Metrics Objective Use financial modeling of your data center costs to optimize their utilization. Data Centers are Expensive

More information

Alternative data center power

Alternative data center power Alternative data center power A quantitative TCO comparison of 400V AC and 600V AC power systems Abstract Power efficiency has become a critical focus for IT and facilities managers as they struggle to

More information

Virginia Tech. Background. Case Summary. Results

Virginia Tech. Background. Case Summary. Results Background Virginia Tech When Virginia Tech initiated plans to build a supercomputer by clustering hundreds of desktop computers, it had ambitious goals for the performance of the new system and a very

More information

Future-Proof the Banking and Finance Data Center

Future-Proof the Banking and Finance Data Center Future-Proof the Banking and Finance Data Center Reinier Dungca Rey Perea Marketing Manager, Southeast Asia and North Asia Manager, Local Technical Support Emerson Network Power Emerson Network Power Philippines

More information

How To Test A Theory Of Power Supply

How To Test A Theory Of Power Supply A CASE STUDY ON: THE EFFECTS OF HIGHER OPERATING TEMPERATURES ON DATA CENTER EFFICIENCY Victor Garcia Director of Facilities Brocade October 24, 2012 Jeff Stein, PE Principal Taylor Engineering 2010 Brocade

More information

Modular Data Centre. Flexible, scalable high performance modular data centre solutions. Data Centre Solutions...energy efficient by design

Modular Data Centre. Flexible, scalable high performance modular data centre solutions. Data Centre Solutions...energy efficient by design Data Centre Solutions...energy efficient by design Modular Data Centre Flexible, scalable high performance modular data centre solutions Creating an effective workspace environment The Modular Data Centre

More information

Eudemon8000 High-End Security Gateway HUAWEI TECHNOLOGIES CO., LTD.

Eudemon8000 High-End Security Gateway HUAWEI TECHNOLOGIES CO., LTD. Eudemon8000 High-End Security Gateway HUAWEI TECHNOLOGIES CO., LTD. Product Overview Faced with increasingly serious network threats and dramatically increased network traffic, carriers' backbone networks,

More information

Airflow Simulation Solves Data Centre Cooling Problem

Airflow Simulation Solves Data Centre Cooling Problem Airflow Simulation Solves Data Centre Cooling Problem The owner s initial design for a data centre in China utilized 40 equipment racks filled with blade servers spread out in three rows along the length

More information

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers CEMEP UPS The high environmental performance solution for power supply to high-availability data centers Exchanges of information and communication needs are growing at an exponential rate. That growth

More information

Introducing UNSW s R1 Data Centre

Introducing UNSW s R1 Data Centre Introducing UNSW s R1 Data Centre R1-DC Our New High Density Data Centre Right here Right now - Welcome to our newest UNSW Data Centre R1-DC R1 Location on UNSW Randwick campus. Keeping it in the family

More information