1 DISTRIBUTED REDUNDANCY: MAXIMUM AVAILABILITY AT MINIMAL COST A White Paper by: Liebert Corporation As the need for greater system availability intensifies across virtually every industry from global banking to justin-time manufacturing network, IT, and other information systems managers are asked to guarantee an unprecedented level of computer uptime. To compound the problem, the platforms on which these critical applications reside have never been more vulnerable. They are often a mixture of leading-edge and aging technology and housed far from the protected environments sensitive electronics once enjoyed. This white paper concerns the recently developed power protection system, distributed redundancy. Distributed redundancy ensures 100% power as it dramatically improves power availability, approaching the virtual 100% level. The unprecedented level of power protection is assured regardless of platform, application criticality, or downtime sensitivity when even one hour per year of power system downtime is unacceptable. Moreover, distributed redundancy doesn t compromise any aspect of system management, from the ability to easily perform equipment maintenance to the ability to fit within an investment/liability budgetary ratio. What follows is an examination of factors that led to the need for this level of protection as well as a detailed discussion of the components that comprise distributed redundancy. Information Needs Intensify: What Factors Affect Critical Data Integrity? Four factors combine in today s enterprise to create a business threat: 1. power reliability 2. electric equipment sensitivity 3. the advent of distributed processing 4. reliance on information as a critical, if not primary, business function creating the need for greater system availability. 5. Reliability is defined as the probability that some item will perform as intended for a specified period of time and under a stated set of conditions. It may seem as though power reliability is no longer an issue, particularly for USbased organizations. Power outages long enough to notice happen only a few times a year. But in most parts of the country, power fluctuations occur at an average of nearly one a day. One daily fluctuation is enough to cause many unexplained system problems. Effects can include system and drive crashes, data transmission errors or shutdowns, server shutdowns and reboots, even premature component failure. Micro-computers left the glass house as they became more tolerant of everyday office conditions. Unconnected, problems remained isolated. Today, high-speed computing and communications technologies across networks of every size are becoming the norm. So higher levels of sensitivity are creeping back into network hardware. An additional consideration: power fluctuations aren t the only problems out in the real world. Heat, dust, vibration and people can bring down a network even if the power source is perfect. Finally, the need for high availability is increasing at incredible rates, often approaching 100%. When the system goes down, the work place slows to a crawl or stops altogether. This is true across all industries, whether the organization is service-based or manufacturing. Determining Fault Tolerance: How Much is Enough Protection? Each year Contingency Planning Research (CPR) polls firms in various industries to identify the costs when vital networks go down for just one hour (Figure 1). Results range from a package shipping service with an hourly financial impact of up to $32,000 to an airline reservation center that tops out at a $112,000 loss per hour.
2 What Does it Really Cost? Each year, Contingency Planning Research (CPR) polls firms in various industries to identify the costs when vital networks go down for just one hour. The results are sobering: BUSINESS OPERATION HOURLY FINANCIAL IMPACT (RANGE) 900 Number Services $54,000-$70,000 Airline Reservation Centers $67,000-$112,000 Bank ATM Service Fees $12,000-$17,000 Stock Brokerage House $5.6-$7.3 million Catalog Sales Centers $60,000-$112,000 Cellular Service Activation $38,000-$44,000 Credit Card Sales Authorizations $2.2-$3.1 million Informecrcial 800 Number $175,000-$224,000 Promotions Network Connection Fees $23,500-$32,000 Package Shipping Service Requests $24,500-$32,000 Telephone Ticket Sales $56,000-$82,000 Are any of these business operations similar to yours? What would it cost you if they went down for an hour? To identify the level of power protection right for your organization, you must first determine your acceptable level of fault tolerance. Fault tolerance encompasses not only how quickly the network can recover from a power failure, but also how much protection it needs against both slow and fast power failures. Two elements have been used to determine fault tolerance. The most common is the acceptable mean time between failure or MTBF. A less understood but perhaps a more relevant determiner of acceptable fault tolerance is represented by redundancy objectives as they apply to protecting the network. Much has been published among business equipment suppliers and IS managers about MTBF. By definition, it is the average time before failure of an item under a specified set of conditions. The MTBF for critical support systems, such as UPSs, should be as high as 10 times the load MTBF. In and of itself, MTBF data has limited usefulness. By its very nature as an average, it tends to obscure critical information. The most basic MTBF calculations assume gaussian (normal) data distribution, which can distort or ignore many of the real-world challenges your network may face. For these reasons and others, the MTBF
3 characteristic alone should never be mistaken for a measure of availability; a predictor of risk failure prior to the calculated MTBF elapsed time; or an excuse to value one particular MTBF number over another. Redundancy objectives can serve as much more realistic predictors of your necessary level of fault tolerance. These objectives are formed around the question: how much protection is enough? Redundancy objectives hold 7x24x365 as the operational goal; adhere to a flexible power distribution; and plan for maintenance and upgrades without shutdown. If 100% availability seems too high for your system, consider what 99.9% availability translates into across user applications. One hour of unsafe drinking water. Two unsafe plane landings per airport per day. Twenty thousand incorrect surgical operations per week. Twenty-two thousand checks deducted from the wrong account every hour. Rating the Options: Traditional to Distributed Redundancy There are several levels of traditional configurations designed for power reliability and availability. However, many obvious and hidden factors affect the level achievable by these configurations. Single Module. Single Module Systems are popular and perhaps the most well known. They are typically configured as: Single Module Systems provide adequate continuous power protection under certain conditions. The UPS must be a true on-line topology; a static bypass switch should be in place to provide the utility to the load in the event of a UPS transfer from its inverter; and the entire critical load demand for the facility should not exceed 1000kVA. Disadvantages remain numerous and sometimes hidden among the statistics of an average MTBF of ( 100,000 hours. For example, there is only a 37% chance of achieving this MTBF figure. One reason may be the UPS itself. A UPS that has not been factory - or field-tested can actually reduce expected reliability by experiencing both infant mortality (e.g., failing soon after installation) and age-imposed mortality (i.e., factors that impact the longevity of the unit). Liebert s 600T, on the other hand, has a field-proven MTBF of > 1M hours. Another challenge with this configuration: the UPS has to be taken off-line for maintenance, service and IEEE battery testing as well. Therefore, it is obviously not available to the load at these times. A typical single module application would involve an information-intensive but not critical environment such as a hospital administration system (versus diagnostic systems).
4 Isolated Redundancy. An alternate UPS configuration is an isolated redundant configuration as shown in Figure 4. Isolated Redundant UPS In this configuration, a reserve UPS module supplies the bypass input of the primary UPS device. In this way, protection against the primary module s failure is obtained. This is true when the primary bypass power is not available as well during periods of primary UPS module maintenance. However, a distinct disadvantage of isolated redundancy is the same as its strength: the fact the entire load resides on a primary UPS until the moment when it is needed most i.e., at the point of power failure. This creates the potential for many risks. First and most obvious, the stand-by UPS must accept up to a 100% step load. Then, not only must the primary module s static bypass switches operate properly to obtain power from the reserve module, but also (should an output overload have occurred) both static switches must properly detect the situation and supply current from the utility source. Variations on the isolated redundancy configuration have included a single reserve module as backup to several independent primary UPSs. The reserve UPS generally is sized to support only one of the primary modules. This requires such complexity in the switch gear configurations and associated controls that it usually offsets any reliability gains. Parallel/Tied Systems. Another redundancy approach is the use of parallel redundant UPS modules with a static bypass switch as shown here.
5 Parallel Redundant (N+1) UPS While this is the most widely applied approach, it does require careful application of the number of UPS modules and their configuration. Principles of reliability dictate the fewer parallel modules required for the load capacity, the better. Consider that the calculated system MTBF of two parallel redundant modules is 2.27 million hours. The MTBF of the same UPS modules where three are used in the configuration drops to 757 thousand hours. When six of the same UPS modules are required with one module being redundant, the MTBF is reduced further to only 151 thousand hours. A variation of the parallel redundant system is the 1+1 configuration. As seen in this configuration, two single module UPS, each with an internal static switch, are connected in parallel. 1+1 Parallel Redundant UPS Some form of system-level control is still required to allow the modules to share the load and control transfers to the bypass source. Multiple static bypass switches must operate in parallel for proper reaction transfers and overload conditions. Further, system level maintenance bypass (which is not shown in Figure 6) is still required to do system level maintenance. Distributed Redundancy. The distributed redundant configuration requires a complete change in the approach to large UPS design. This change in thinking is probably best reflected in a recent Uptime Institute survey of large data processing center downtime. According to survey results, 79% of electrical infrastructure failures that caused interruption of critical load operation occurred between the UPS output bus and the critical load. The emphasis of critical power system designers needs to shift from building a bullet proof UPS system to creating a fault-tolerant uninterruptible power of the UPS to the input terminals of the load equipment. This change in thinking is reflected in the following configuration:
6 Distributed Redundant Dual UPS Bus System In its basic form, distributed redundancy involves creating dual, full capacity UPS system busses and redundant power distributed systems. This eliminates as many single points of failure as practical, all the way up to the load equipment s input terminals. In order to provide fault tolerance, some method of allowing the load equipment to receive power from both UPS power busses must be provided. Protecting against fast power system failures, such as circuit breaker trips or a power system fault, requires a commensurably fast switching method. Static transfer switches (STSs) have been applied to accomplish very fast break-before-make transfers between two AC power sources. It is important that the two AC power sources be designed as independent as practical to eliminate any common failures. Switching between the two power sources needs to be break-before-make for the same reason. A number of distributed redundancy power distribution configurations can be devised. Keep in mind, however, that redundancy needs to be as close to the load as possible to achieve its goal namely, keeping power available at the load equipment level. The ultimate distributed redundancy configuration would be two independent UPS power distribution systems with dual-input load equipment as redundant AC power is provided up to and inside the load equipment. Some may see the use of dual- input load equipment in this ultimate implementation as a drawback. After all, power system designers have little or no control over the selection or implementation of this type of load equipment. Remember, however, that more and more information technology equipment is being designed with dual-input capability. In this way, distributed redundancy not only provides the best assurance of power reliability and availability, but it also paves the way for an easy migration path as more dual-bus loads become deployed. Distributed Redundancy: A Critical Part of the Business Plan How can you determine if distributed redundancy is right for you? If high reliability, high availability and high probability of achieving the predicted MTBF are required, then redundancy such as that found in the parallel redundant configuration is a must. If loads are ultra- critical (i.e., you bought a very high MTBF/availability concept from your business equipment supplier) then the power system will need to be about 10 times more reliable than the load and redundant to avoid compromising the initial investment as well as the overall business plan. This almost certainly points to a distributed redundancy configuration. MEAN TIME BEFORE FAILURE (MTBF) 1.New Equipment Investment 2.Revenue 3.Case Savings YR1 YR2 YR3
7 4.Expense (Non Cash) 5.Depreciation ACRS 6.Materials Trade-In 7.Profit Improvement BIT (3-8+9) 8.Less Income Tax (%) 9.Investment Tax Credit 10.Net Profit Improvement (7-8+9) 11.Clash Flow (1+5+10) 12.Payback (cumulative cash flow) 13.PV ( % factor) 14.Discounted Cash Flow (11 x 13) 15.Net PV Cash Flow (14) 16.Return on Investment (10/1) Remember that facilities support systems cost nothing, just as critical loads cost nothing. Both are investments as opposed to overhead costs. This means they are expected to make money and to work to required levels within the business plan. The performance of the investment is the issue, not protection. Therefore, all components of the distributed redundancy configuration should be considered part of a performance package, not optional functions. # # # NOTE: You may obtain more information about distributed redundancy specific to your organization by calling Liebert Corporation, ; writing Liebert Corporation, 1050 Dearborn Drive, Columbus, OH 43229; or visiting the Liebert website: The Components of Configuration: Some Basic Definitions UPS: uninterruptible power supplies a power conditioning and supply system that provides protection against short-term power outages. Inverter: the DC to AC power converter driven by a UPS rectifier charger or battery via a DC bus. The inverter output drives the critical load, for example. Bus: a communication channel to which devices connect; many of today s IS managers must deal with a mixture of singleand dual-bus input devices. STS: a static transfer switch utilized to transfer between two sources of AC power close to the critical load. PDU: a power distribution unit that manages and protects sensitive electronic loads. About Liebert Corp. Headquartered in Columbus, Ohio, Liebert Corporation is an independent subsidiary of Emerson Electric Co. Liebert offers the broadest range of products in the power protection industry, from simple surge protection and power conditioning to Uninterruptible Power Supplies (UPSs) in an array of sizes, configurations and topologies. Represented in more than 100 countries, Liebert products are widely used in network, telecommunications, and medical imaging and industrial automation applications. Frost & Sullivan reports that among UPS end users, Liebert is the leading manufacturer in brand recommendation and brand use among Fortune 1000 companies. LIEBERT WEB NOTICE AND CONDITIONS Copyright Liebert Corporation. For more information, contact [email protected].
IT White Paper. N + 1 Become Too Many + 1?
IT White Paper Balancing Scalability and Reliability in the Critical Power system: When Does N + 1 Become Too Many + 1? Summary Uninterruptible Power Supply (UPS) protection can be delivered through a
IT White Paper IP TELEPHONY AND RELIABILITY: PROTECTING MISSION-CRITICAL PHONE SYSTEMS FROM POWER THREATS
IT White Paper IP TELEPHONY AND RELIABILITY: PROTECTING MISSION-CRITICAL PHONE SYSTEMS FROM POWER THREATS Executive Summary IT managers who are used to implementing power protection for IT network or data
High-Availability Power Systems, Part II: Redundancy Options
Liebert July 2003 High-Availability Power Systems, Part II: Redundancy Options SUMMARY High-Availability power systems require Reliability, Functionality, Maintainability, and Fault Tolerance. A few UPS
Advantages and Efficient Use of Programmable Sockets. By Miguel Rascon AC Power Senior Product Manager
Advantages and Efficient Use of Sockets By Miguel Rascon AC Power Senior Product Manager Abstract Emerson Network Power s most recent products feature programmable s embedded in the UPS to provide the
Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM
Power Management Strategies for High-Density IT Facilities and Systems A White Paper from the Experts in Business-Critical Continuity TM Executive Summary Increases in data center density and diversity
Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity
Modular architecture for high power UPS systems A White Paper from the experts in Business-Critical Continuity Abstract Today, more than ever before, energy efficiency and cost-savings are among the top
High Availability White Paper
High Availability White Paper This document provides an overview of high availability best practices for mission critical applications. Author: George Quinlan, Senior Consultant Background - High Availability
Industrial Ethernet How to Keep Your Network Up and Running A Beginner s Guide to Redundancy Standards
Redundancy = Protection from Network Failure. Redundancy Standards WP-31-REV0-4708-1/5 Industrial Ethernet How to Keep Your Network Up and Running A Beginner s Guide to Redundancy Standards For a very
Qualitative Analysis of Power Distribution Configurations for Data Centers
Qualitative Analysis of Power Distribution Configurations for Data Centers White Paper #4 2007 The Green Grid. All rights reserved. No part of this publication may be used, reproduced, photocopied, transmitted,
Opportunity of Energy Saving in electrical path is lesser as compared to other areas
Data Centre Power Map ` Energy Optimization Techniques Data Center Power Chain Venkat Rao B Country Manager Power Products Data Center Power Draws Cooling About 35 40 % Sources of Energy Waste Fans / Blowers
7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications
W H I T E P A P E R Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications Executive Summary One of the fundamental decisions in the design of data centers, server rooms
The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity
The Quest for Energy Efficiency A White Paper from the experts in Business-Critical Continuity Abstract One of the most widely discussed issues throughout the world today is the rapidly increasing price
Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity
Proper Application of 415V Systems in North American Data Centers A White Paper from the Experts in Business-Critical Continuity Introduction Increasing pressure to reduce operating expenses and be more
Evaluating the Opportunity for DC Power in the Data Center
A White Paper from the Experts in Business-Critical Continuity Evaluating the Opportunity for Power in the Data Center by Mark Murrill and B.J. Sonnenberg, Emerson Network Power Summary With data center
Designed for uptime. Defining data center availability via a tier classification system
Defining data center availability via a tier classification system MIETEK GLIKOWSKI All systems can fail this is a simple fact that every industry must deal with. The paramount concern for the data center
30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
Enterprise Remote Monitoring
Enterprise Remote Monitoring Alarm Management, Predictive Maintenance, Advanced Network Security Services For Business-Critical Continuity Can You Really Afford Not To Know? Loss of productivity and the
Power Quality. Uninterruptible Power Supply
Quality Uninterruptible Supply In the electrical system environment, power disturbances will occur. These can be caused by faults on the distribution system, the operation of nearby equipment, lightning
Power to the adaptable data center
Business Unit Manager, Data Center Solutions, Eaton s electrical group IT managers have more options than ever to tailor the power infrastructure to their unique data center and business requirements.
A COMPARISON OF TYPICAL UNINTERRUPTIBLE POWER SUPPLY (UPS) DESIGNS IN TODAY S MARKETS
A COMPARISON OF TYPICAL UNINTERRUPTIBLE POWER SUPPLY (UPS) DESIGNS IN TODAY S MARKETS October 22, 2010 Authored by: Kevin Binnie, Senior Product Portfolio Manager ALPHA TECHNOLOGIES LTD. Executive Summary
Maximizing UPS Availability
Maximizing UPS Availability A comparative assessment of UPS designs and deployment configurations for the highavailability data center By Chris Loeffler Product Manager, BladeUPS & Data Center Applications
Redundant Gigabit Backbone Adds Speed and Reliability to Industrial Networks
Adds Speed and Reliability to Industrial Networks by Harry Hsiao, MOXA Product Manager [email protected] Introduction Gigabit network applications are becoming more and more popular in the modern networking
Red Hat Enterprise linux 5 Continuous Availability
Red Hat Enterprise linux 5 Continuous Availability Businesses continuity needs to be at the heart of any enterprise IT deployment. Even a modest disruption in service is costly in terms of lost revenue
Availability and Disaster Recovery: Basic Principles
Availability and Disaster Recovery: Basic Principles by Chuck Petch, WVS Senior Technical Writer At first glance availability and recovery may seem like opposites. Availability involves designing computer
Security+ Guide to Network Security Fundamentals, Fourth Edition. Chapter 13 Business Continuity
Security+ Guide to Network Security Fundamentals, Fourth Edition Chapter 13 Business Continuity Objectives Define environmental controls Describe the components of redundancy planning List disaster recovery
Common Power Problems & Power Protection Solutions
W H I T E P A P E R Common Power Problems & Power Protection Solutions Executive Summary All systems, from home theaters and office desktops to enterprise IT equipment in data centers, are prone to downtime,
UPS For Efficient Data Data Centers Centers
UPS For Efficient Data Centers Eaton Corporation Agenda (1) Introduction Basics About UPS s (2) Trends and Challenges Affecting The Power Infrastructure Of Your Data Center (3) Selecting The Right Power
Creating A Highly Available Database Solution
WHITE PAPER Creating A Highly Available Database Solution Advantage Database Server and High Availability TABLE OF CONTENTS 1 Introduction 1 High Availability 2 High Availability Hardware Requirements
Understanding Delta Conversion Online "Output Power Factor Ratings" - Part 7
Application Note #45 Understanding Delta Conversion Online "Output Power Factor Ratings" - Part 7 Introduction This application note is the seventh in a series on delta conversion theory of operation.
Increased power protection with parallel UPS configurations
Increased power protection with parallel UPS configurations Making the selection between Centralized Bypass and Distributed Bypass systems Janne Paananen Application Engineer, Large Systems Group Eaton
The Different Types of UPS Systems
The Different Types of UPS Systems By Neil Rasmussen White Paper #1 Revision 5 Executive Summary There is much confusion in the marketplace about the different types of UPS systems and their characteristics.
Power and Cooling Best Practices for IP Communications. A White Paper from the Experts in Business-Critical Continuity
Power and Cooling Best Practices for IP Communications A White Paper from the Experts in Business-Critical Continuity Executive Summary IP telephony and Power over Ethernet (PoE) are driving the requirement
Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity
Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection AC Power for Business-Critical Continuity Liebert GXT MT+ CX UPS, 1000VA -3000VA Intelligent, Reliable UPS Protection Liebert
Alternative data center power
Alternative data center power A quantitative TCO comparison of 400V AC and 600V AC power systems Abstract Power efficiency has become a critical focus for IT and facilities managers as they struggle to
Selecting a UPS Topology for your Data Center. by Dr. Daniel Becker, Ph.D., Methode Active Energy Solutions
Selecting a UPS Topology for your Data Center by Dr. Daniel Becker, Ph.D., Methode Active Energy Solutions Uninterruptible Power Supplies (UPS) are both reaching into new markets and expanding in new ways
Data Center Commissioning: What you need to know
Data Center Commissioning: What you need to know Course # CXENERGY1511 AIA Provider # 50111116 AABC Commissioning Group CxEnergy Conference Henderson, NV April 30, 2015 Presented by: Judson H. Adams, P.E.,
UPS Applications and VRLA Battery Sizing
TECHNICAL BULLETIN 41-7334 UPS Applications and VRLA Battery Sizing 41-7334/0213/CD www.cdtechno.com The uninterruptable power system (UPS) is used to protect critical equipment and processes from the
The Anatomy of a. High-Availability Rack. November 2009. Online Tech, Inc. 220 E. Huron Ann Arbor, MI 48104 (734) 213-2020. www.onlinetech.
Online Technologies Corporation September 2008 If you have questions, please contact: The Anatomy of a Onl (734) 213-2020 phone High-Availability Rack November 2009 Online Tech, Inc. 220 E. Huron Ann Arbor,
Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency
A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency
Fault Tolerance & Reliability CDA 5140. Chapter 3 RAID & Sample Commercial FT Systems
Fault Tolerance & Reliability CDA 5140 Chapter 3 RAID & Sample Commercial FT Systems - basic concept in these, as with codes, is redundancy to allow system to continue operation even if some components
Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services
Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination
AC vs DC for Data Centers and Network Rooms
AC vs DC for Data Centers and Network Rooms White Paper #63 Revision 1 Executive Summary The use of DC power distribution as an alternative to AC in data centers and network rooms is uncommon. The considerations
The Different Types of UPS Systems
Systems White Paper 1 Revision 6 by Neil Rasmussen Contents Click on a section to jump to it > Executive summary There is much confusion in the marketplace about the different types of UPS systems and
Power protection for data centers
Power protection for data centers Power protection for data centers Data centers are major power users, with larger installations consuming tens of megawatts. As customers are often highly reliant on the
Working definitions of terms: Commercial vs. Industrial UPS Systems:
The Essential Differences Between Commercial & Industrial UPS Systems Page 1 of 8 Working definitions of terms: Commercial vs. Industrial UPS Systems: On-Line, Uninterruptible Power Systems (abbreviated:
Predictive Maintenance in a Mission Critical Environment
March 2009 Predictive Maintenance in a Mission Critical Environment This paper discusses the need to proactively protect mechanical and electrical support systems in data processing centers and data storage
System Migrations Without Business Downtime. An Executive Overview
System Migrations Without Business Downtime An Executive Overview Businesses grow. Technologies evolve. System migrations may be inevitable, but business downtime isn t. All businesses strive for growth.
Maximizing Data Center Uptime with Business Continuity Planning Next to ensuring the safety of your employees, the most important business continuity
Maximizing Data Center Uptime with Business Continuity Planning Next to ensuring the safety of your employees, the most important business continuity task is resuming business critical operations. Having
Liebert : The Right Cooling For IT Environments. Precision Cooling For Business-Critical Continuity
Liebert : The Right Cooling For IT Environments Precision Cooling For Business-Critical Continuity New Challenges To IT System Uptime Many IT professionals are finding that dedicated precision cooling
Fundamentals of Power
Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At
Ambient Temperature In Range Probe X
List of Events This section lists all events that are written to the Event Log. Some of these events can be configured through the Configuring Events to Take Actions page, and these are listed in the first
Power backup in data centers. Something going on. 24 I MTU Report 03/10
Power backup in data centers Something going on 24 I MTU Report 03/10 Energy All over the world, Internet commerce is growing at an incredibly rapid rate as more and more people become accustomed to banking,
Tough Decision: On-Line or Line-Interactive UPS?
W H I T E P A P E R Tough Decision: On-Line or Line-Interactive UPS? How to Choose the Right Protection for Your Network Executive Summary In today s data-driven, technology-dependent world, no organization
BICSI 002 / TIA 942 / Uptime
BICSI 002 / TIA 942 / Uptime Which Data Center Standard Should I Follow Phil Isaak, PE, P.Eng., RCDD, DCDC President, Master Instructor Isaak Technologies Inc. Standards Who are these People Standards
Parallel UPS configurations Connecting multiple UPS modules for added capacity or redundancy
Parallel UPS configurations Connecting multiple UPS modules for added capacity or redundancy By Ed Spears Product Manager, Eaton Power Quality Solutions Operation Abstract Increasingly, organizations are
A Comparison of AC and DC Power Distribution in the Data Center Transcript
A Comparison of AC and DC Power Distribution in the Data Center Transcript Slide 1 Welcome to the Data Center University course on the A Comparison of AC and DC Power Distribution in the Data Center. Slide
The Effect of Regular, Skilled Preventive Maintenance on Critical Power System Reliability
The Effect of Regular, Skilled Preventive Maintenance on Critical Power System Reliability A White Paper from the Experts in Business-Critical Continuity TM Executive Summary Emerson Network Power has
Welcome to the Tripp Lite UPS Systems Basics training module, part of Tripp Lite's "Products Expert" training course. 2008 Tripp Lite.
Welcome to the Tripp Lite UPS Systems Basics training module, part of Tripp Lite's "Products Expert" training course. 2008 Tripp Lite. All rights reserved. The policy of Tripp Lite is one of continuous
Is an energy-wasting data center draining your bottom line?
Abstract Is an energy-wasting data center draining your bottom line? New technology options and power distribution strategies can dramatically reduce the cost and carbon footprint of your data center.
Liebert APM from 30-150 kw. The Compact Row-Based UPS With FlexPower Technology TM
Liebert APM from 30-150 kw The Compact Row-Based UPS With FlexPower Technology TM Emerson Network Power, a division of Emerson, is a global company that combines technology with design to supply innovative
Increasing safety, reliability and efficiency for today s data centers
Increasing safety, reliability and efficiency for today s data centers Products and expertise for data center success Drawing upon vast experience in complex industries where uptime is critical, ABB provides
Five Nines and Infrared (IR) Testing at Data Centers
Five Nines and Infrared (IR) Testing at Data Centers By Gregory R. Stockton 99.999% uptime five nines. That is what IT (information technology) customers are looking for. Uptime or availability at data
Business Continuity: Choosing the Right Technology Solution
Business Continuity: Choosing the Right Technology Solution Table of Contents Introduction 3 What are the Options? 3 How to Assess Solutions 6 What to Look for in a Solution 8 Final Thoughts 9 About Neverfail
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications
Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability
Considerations for a Highly Available Intelligent Rack Power Distribution Unit A White Paper on Availability Introduction Data centers are currently undergoing a period of great change. Data center managers
High Availability Server Clustering Solutions
White Paper High vailability Server Clustering Solutions Extending the benefits of technology into the server arena Intel in Communications Contents Executive Summary 3 Extending Protection to Storage
The Different Types of UPS Systems
White Paper 1 Revision 7 by Neil Rasmussen > Executive summary There is much confusion in the marketplace about the different types of UPS systems and their characteristics. Each of these UPS types is
MaximumOnTM. Bringing High Availability to a New Level. Introducing the Comm100 Live Chat Patent Pending MaximumOn TM Technology
MaximumOnTM Bringing High Availability to a New Level Introducing the Comm100 Live Chat Patent Pending MaximumOn TM Technology Introduction While businesses have become increasingly dependent on computer-based
BUILDING THE CARRIER GRADE NFV INFRASTRUCTURE Wind River Titanium Server
BUILDING THE CARRIER GRADE NFV INFRASTRUCTURE Wind River Titanium Server TABLE OF CONTENTS Executive Summary.... 2 NFV Benefits... 2 Service Outage Challenge.... 2 NFV Carrier Grade Server.... 3 Wind River
Reducing the Risk, Cost and Frequency of Production Stoppages Using Network Redundancy
Introduction Reducing the Risk, Cost and Frequency of Production Stoppages Using Network Redundancy By Mike Miclot, Vice President of Marketing, Industrial Solutions Division at Belden and John Mower,
MGE Galaxy 7000. 160/200/250/300/400/500 kva Power efficiency for business continuity
MGE Galaxy 7000 160/200/250/300/400/500 kva Power efficiency for business continuity Performance three-phase power protection with high adaptability to meet the unique requirements of medium to large data
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
Electrical Systems. <Presenter>
Review Root Causes of Energy Inefficiency Roadmap to Maximize Energy Efficiency Best Practices Alternative Energy Sources Controls Take Aways Seek Professional Help. ENERGY INEFFICIENCY OF
10 How to Accomplish SaaS
10 How to Accomplish SaaS When a business migrates from a traditional on-premises software application model, to a Software as a Service, software delivery model, there are a few changes that a businesses
SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity
SmartDesign Intelligent, Integrated Infrastructure For The Data Center Solutions For Business-Critical Continuity Prepare Your Data Center For What s Next Efficiency. Availability. Capacity. Control. One
All Clouds Are Not Created Equal THE NEED FOR HIGH AVAILABILITY AND UPTIME
THE NEED FOR HIGH AVAILABILITY AND UPTIME 1 THE NEED FOR HIGH AVAILABILITY AND UPTIME All Clouds Are Not Created Equal INTRODUCTION Companies increasingly are looking to the cloud to help deliver IT services.
N.K. Srivastava GM-R&M-Engg.Services NTPC- CC/Noida [email protected]
N.K. Srivastava GM-R&M-Engg.Services NTPC- CC/Noida [email protected] JULY 2012 ARC- Transforming Industry and Infrastructure through New Processes and Technologies Presentation Road Map Introduction
CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers
CEMEP UPS The high environmental performance solution for power supply to high-availability data centers Exchanges of information and communication needs are growing at an exponential rate. That growth
PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions
PMCS Integrated Energy Management Solution Unlock the Full Potential of Power Networks Through Integration Power Management Control System (PMCS) is a highly customizable, fully integrated end-to-end Energy
> Executive summary. The Role of Isolation Transformers in Data Center UPS Systems. White Paper 98 Revision 0. Contents.
The Role of Isolation Transformers in Data Center UPS Systems White Paper 98 Revision 0 by Neil Rasmussen > Executive summary Most modern UPS systems do not include the internal s that were present in
The Real Cost of Manual Asset Management
The Real Cost of Manual Asset Management No Limits Software White Paper #3 By David Cole 2011 No Limits Software. All rights reserved. No part of this publication may be used, reproduced, photocopied,
Standardization and modularity as the foundation of data center UPS infrastructure
ABB White Paper Standardization and modularity as the foundation of data center UPS infrastructure - ABB Power Protection Product Group Doc name: Advantages of modular and standardized UPS Date: 19.11.2013