CREEK Technical Services, LLC
|
|
- Robert Griffith
- 8 years ago
- Views:
Transcription
1 EVALUATION REPORT 2010 FLORIDA BUILDING CODE Manufacturer: Henry Company Report Issued February 20, North Sepulveda Blvd., Suite 800 El Segundo, CA (800) Manufacturing Plants: Quality Assurance: Bartow, FL Scarbourgh, Ontario PRI Construction Materials Technologies (QUA9110) SCOPE Category: Roofing Subcategory: Cements-Adhesives-Coatings Code Sections: , , Properties: Material Standards REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) HGC ASTM D e01 PRI Construction Materials Technologies (TST5878) HGC ASTM D (2007) PRI Construction Materials Technologies (TST5878) HGC ASTM D (2007) PRI Construction Materials Technologies (TST5878) HGC ASTM D (2007) PRI Construction Materials Technologies (TST5878) HGC ASTM D PRI Construction Materials Technologies (TST5878) HGC ASTM D PRI Construction Materials Technologies (TST5878) HGC ASTM D PRI Construction Materials Technologies (TST5878) HGC TAS 114(H) 1995 PRI Construction Materials Technologies (TST5878) HGC ASTM D PRI Construction Materials Technologies (TST5878) HGC ASTM D PRI Construction Materials Technologies (TST5878) HGC ASTM D PRI Construction Materials Technologies (TST5878) HGC TAS PRI Construction Materials Technologies (TST5878) HGC ASTM D (2007) PRI Construction Materials Technologies (TST5878) HGC ASTM D PRI Construction Materials Technologies (TST5878) HGC ASTM D PRI Construction Materials Technologies (TST5878) HGC ASTM D PRI Construction Materials Technologies (TST5878) HGC ASTM D PRI Construction Materials Technologies (TST5878) HGC ASTM D PRI Construction Materials Technologies (TST5878) HGC ASTM D PRI Construction Materials Technologies (TST5878) HGC ASTM D PRI Construction Materials Technologies (TST5878) HGC ASTM D PRI Construction Materials Technologies (TST5878) HGC ASTM D HEN13001 FL10889 Page 1 of 5
2 PRODUCT DESCRIPTION & APPLICATION Unless otherwise noted, all surfaces shall be clean, dry, and free of oil, grease, rust, scale, or other debris prior to application. Unless otherwise noted, coatings are not recommended over gravel, rubber or PVC sheet roofing, shingles of any kind, nor old, dry, brittle roofs unable to withstand shrinkage stresses. Consult product data sheets for detailed application instructions. HE505 FLASHMASTER FLASHING HE906 FLASHMASTER PLUS HE208 WET PATCH TM ROOF LEAK REPAIR HE204 PLASTIC ROOF HE554 GOLD MEDAL MB FLASHING HE208R RUBBERIZED WET PATCH ROOF LEAK REPAIR HE107 ASPHALT EMULSION SEALER AND DAMPROOFER HE555 ALUMINUM HE555FR ALUMINUM HE280DC WHITE ELASTOMERIC ASTM D 4586, Type I trowel-grade flashing cement made from heavybodied asphalt reinforced with organic fibers applied 1/8-inch thick at a rate of 1 gal/12.5 ft 2. Use with asphalt coated, SBS modified, metal and masonry ASTM D 4586, Type I and ASTM D 3409 trowel-grade rubber polymer modified mastic compound of asphalt, organic fibers and mineral fillers applied to wet or dry surfaces 1/8-inch thick at a rate of 1 gal/12.5 ft 2. Use with asphalt composition, SBS modified, metal and masonry ASTM D 4586, Type I/II and ASTM D 3409 trowel-grade compound for sealing roof leaks on wet surfaces applied 1/8-inch thick at a rate of 1 gal/12.5 ft 2. Use with asphalt, BUR, SBS modified, metal and masonry ASTM D 4586, Type I trowel-grade sealant made from refined asphalt for dry surfaces. Applied 1/8-inch thick at a rate of 1 gal/12.5 ft 2. ASTM D 4586, Type I Class I, trowel-grade rubberized flashing cement designed for use with SBS modified bituminous roofing and asphalt coated membranes. Applied at a rate of 1 gal/ 12.5 ft 2. ASTM D 4586, Type I Class II and ASTM D 3409, trowel-grade SBS modified bitumen used for repair of roof leaks on wet surfaces. Applied at a rate of 1 gal/ 12.5 ft 2. Use with asphalt, BUR, SBS modified, metal and masonry ASTM D 1227, Type II Class I, brush/spray-grade asphalt emulsion coating used for maintenance of roofing materials applied at a rate of 3-4 gal/ 100 ft 2. Use with composition ASTM D 2824, Type III, fibered aluminum roof coating used for maintenance of roofing materials. Applied at a rate of gal/ 100 ft 2. Use with asphalt, BUR, modified bituminous, and weathered galvanized and tin ASTM D 2824, Type III, applied at a rate of gal/ 100 ft 2. Use with asphalt, BUR, modified bituminous, metal, and primed masonry ASTM D 6083 water-based acrylic latex coating. Application rates are as follows: Smooth Surfaces: 2 to 2-1/2 gal/100 ft 2 applied in two coats Mineral Cap Sheet: 2 to 3 gal/ 100 ft 2 applied in two coats Use with concrete, galvanized steel, SBS modified, BUR, EPDM, and PVC. HEN13001 FL10889 Page 2 of 5
3 HE289 WHITE ROOFING SEALANT HE553 MBA GOLD MODIFIED BITUMEN ADHESIVE HE201 FIBERED BLACK ROOF COATING HE ASPHALT PRIMER PRO-GRADE ALL WEATHER FLASHING #27; PRO-GRADE ALL WEATHER FLASHING #225 PRO-GRADE SILVER MEDAL MB FLASHING #531 ELASTOMERIC PRO-GRADE 226 PLASTIC ROOF PRO-GRADE 812 FIBERED ALUMINUM PRO-GRADE 832 FIBERED ALUMINUM TAS 139, white, elastomeric patching compound used for repair of roof leaks prior to coating. Applied at a rate of 1 gal/ 12.5 ft 2. Use with SBS modified, metal, and masonry ASTM D 3019, Type III, fibrated rubberized adhesive for use with adhering modified bituminous and asphalt coated membranes. Applied at a rate of 1.5 gal/ 100 ft 2. ASTM D 4479, Type I, brush or spray-grade used for maintenance of roof materials. Applied at a rate of 1.5 gal/ 100 ft 2. Use with metal, SBS modified, or composition ASTM D 41 Type II, asphalt primer for use with smooth surface roofs, concrete, masonry, brick, and metal surfaces. Applied at a rate of 1 gal/200 ft 2. ASTM D 4586, Type I Class II and ASTM D 3409, trowel-grade flashing cement for sealing roof leaks on dry or wet surfaces applied at a rate of 1 gal/ 12.5 ft 2. ASTM D 4586, Type I Class I, trowel-grade plastic roof cement applied 1/8-inch thick at a rate of 1 gal/ 12.5 ft 2. Use with asphalt, metal and composition roof surfaces. ASTM D 2824, Type III, coating for use with smooth surface asphalt built-up and modified bitumen membranes applied at a rate of 1 gal/ 75 ft gal/ 100 ft 2. ASTM D 2824, Type I coating for use with smooth surface asphalt built-up and modified SBS and APP bitumen membranes. Application rates are as follows: Smooth Surfaces: gal/ 100 ft 2 Mineral Cap Sheet: gal/ 100 ft 2 Masonry and smooth surface SBS and APP roofs surfaced with hot asphalt must first be coated with fully-cured asphalt emulsion. PRO-GRADE 842 FIBERED ALUMINUM PRO-GRADE 331 COLD PROCESS ROOF ADHESIVE PRO-GRADE 441 FIBERED ROOF COATIING ASTM D 2824, Type III, coating for use with built-up asphalt, prepared roll roofing, smooth surface modified bitumen membranes, weathered galvanized iron or tin applied at a rate of gal/ 100 ft 2. ASTM D 3019, Type III, brush-grade, cold-applied, adhesive for use with asphalt coated or self-adhering modified bitumen products applied at a rate of 2 gal/ 100 ft 2. ASTM D 4479, Type I, heavy-bodied asphalt coating reinforced with fiber applied at a rate of 2 gal/ 100 ft 2. Use with asphalt, metal and composition roofs HEN13001 FL10889 Page 3 of 5
4 PRO-GRADE 535 SILVER MEDAL MBA MODIFIED BITUMEN ADHESIVE PRO-GRADE 162 FIBERED ASPHALT EMULSION BULL 100 PREMIUM ALUMINUM ROOF COATING BULL 900 SPECIAL FLASHING BULL 700 PLASTICE ROOF BULL 200 ASPHALT PRIMER SL1100- SUNNILAND PLASTIC SL1400 SUNNILAND PREMIUM MODIFIED SL1300 SUNNILAND ALL WEATHER FLASHING PR300 PREMIER PLASTIC ROOF PR350 PREMIER WET OR DRY PLASTIC ROOF PR400 PREMIER COLD PROCESS ADHESIVE ASTM D 3019, Type III, fibrated, rubberized adhesive for use with SBS modified bitumen and asphalt-coated membranes applied at a rate of 1.5 gal/ 100 ft 2. Not to be used with SBS membranes single ply with polyethylene backing or APP products. ASTM D 1227, Type II Class I, brush/spray-grade coating of an asphalt base with a clay emulsion that contains mineral fibers for use in damp proofing new or existing asphalt roofs, galvanized or ungalvanized metal, composition roofing or periodic maintenance recoating applied in two coats at a rate of 3-5 gal/ 100 ft 2 /coat. ASTM D 2824, Type III, coating used for smooth surface asphat builtup, modified bitumen membranes and metal applied at a rate of 1 gal/ 75 ft 2-1 gal/ 100 ft 2. compound for roof flashings applied to wet or dry surfaces 1/8-inch thick at a rate of 1 gal/ 12.5 ft 2. ASTM D 4586, Type I Class I, trowel-grade mastic compound applied 1/8-inch thick at a rate of 1 gal/ 12.5 ft 2. Not for use over coal tar. ASTM D 41 Type II, solution of asphalt base in a petroleum solvent applied at a rate of 0.5 gal/ 100 ft 2. ASTM D 4586, Type I Class I, trowel-grade mastic compound for vertical and horizontal applications applied 1/8-inch thick at a rate of 1 gal/ 12.5 ft 2. For use repairing leaks on metal roofs, shingles, composition roofing and asphalt. ASTM D 4586, Type I Class I, trowel-grade mastic compound applied to wet or dry surfaces 1/8-inch thick at a rate of 1 gal/ 12.5 ft 2. For use repairing leaks on metal roofs, shingles, concrete, masonry and brick. Not for use over coal tar. compound for wet or dry surfaces applied 1/8-inch thick at a rate of 1 gal/ 12.5 ft 2. For use repairing leaks on metal roofs, shingles, concrete, masonry and brick. Not for use over coal tar. ASTM D 4586, Type I Class I, trowel-grade mastic applied 1/8-inch thick at a rate of 1 gal/ 12.5 ft 2. For use with asphalt, metal and composition compound for wet or dry surfaces applied 1/8-inch thick at a rate of 1 gal/ 12.5 ft 2. For use repairing leaks in composition, mineral surface cap sheet, asphalt coated, SBS modified, metal, roofs, shingles, concrete, masonry and brick. ASTM D 3019, Type III, cold-applied asphalt roofing adhesive applied at a rate of 2 gal/ 100 ft 2. PR550 PREMIER ALUMINUM ROOF COAT ASTM D 2824, Type III, coating for use on smooth surface asphalt built-up, metal and modified bitumen membranes applied at a rate of gal/ 100 ft 2. HEN13001 FL10889 Page 4 of 5
5 ROOFER S CHOICE ASPHALT EMULSION ASTM D 1227, Type II Class I, brush/spray-grade coating for smooth surfaces applied in one coat or at right angles in two coats at a rate of 3 gal/ 100 ft 2 /coat. LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. Structural integrity of the roofing substrate or assembly is not within scope of this evaluation. Refer to the appropriate product approval for installation of these components within an Approved roof assembly. 3. Installation of the evaluated products shall comply with this report and the manufacturer s published application instructions. 4. Applications are valid for new and existing roof systems. COMPLIANCE STATEMENT The products evaluated herein have demonstrated compliance with the 2010 Florida Building Code as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT HEN13001 FL10889 Page 5 of 5
BITUMINOUS ROOF COATINGS, CEMENTS, PRIMERS AND ADHESIVES
BITUMINOUS ROOF COATINGS, CEMENTS, PRIMERS AND ADHESIVES ABOUT POLYGLASS U.S.A., INC. MODIFIED CEMENTS & ADHESIVES MASTICS ALUMINUM COATINGS EMULSIONS & PRIMERS PROTECTIVE COATINGS Polyglass manufactures
More informationQuality You Can Trust Since 1886... From North America s Largest Roofing Manufacturer
Quality You Can Trust Since 1886... From North America s Largest Roofing Manufacturer Leak Buster Repair & Maintenance Products Quality You Can Trust Since 1886...From North America s Largest Roofing Manufacturer
More informationROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
More informationRoof Systems Overview
Roof Systems Overview Cold Applied Built-Up Roofing Systems BURmastic Tremco s line of cold applied built-up roofing systems. BURmastic 200 Combines Tremco s expertise in asphalt blending technology with
More informationMaintenance & repair Solutions
Maintenance & repair Solutions low-slope ROOFING We ve got what you need in the sizes you need them and the options to match the results that building owners want Seal-fast Temporary roof sealer Now you
More informationWESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM SPECIFICATION NO. SMAA-2P-8xE UPGRADE SMOOTH SURFACE / CAP SHEET / SINGLE PLY 2 PLY POLYESTER REINFORCED ACRYLIC
More informationTable of Contents. Benefits of UNIFLEX Fluid Applied Roofing Systems 2 3. Elastomeric Finish Coats 4 5. Aluminum Finish Coats 6
PORTFOLIO Table of Contents Benefits of UNIFLEX Fluid Applied Roofing Systems 2 3 Elastomeric Finish Coats 4 5 Aluminum Finish Coats 6 Asphalt Emulsion Coatings 7 Base Coats & Primers 8 9 Patch & Repair:
More informationCHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
More informationA. This Section includes rubberized asphalt sheet membrane waterproofing systems.
SECTION 07110 SHEET MEMBRANE WATERPROOFING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationLAMA has developed over the years a wide range of products that can be used in the waterproofing
LAMA has developed over the years a wide range of products that can be used in the waterproofing and damp-proofing of roofs, decks, car parkings, walls, foundations, basements, roads, etc. In this catalogue,
More informationSmooth cap sheet - 0-10 SQ $ 139.00. Smooth cap sheet - 11-50 SQ $ 63.00. Smooth cap sheet - 51-100 SQ $ 36.00 Smooth cap sheet - 101-200 SQ $ 36.
Demolition/Removal of Work 4-ply built up roofing to the insulation (smooth cap sheet) Smooth cap sheet - 0-10 SQ $ 63.00 Smooth cap sheet - 11-50 SQ $ 63.00 Smooth cap sheet - 51-100 SQ $ 35.00 Smooth
More informationRoofing Systems. New Applications / Re-Roofing / Maintenance
Roofing Systems New Applications / Re-Roofing / Maintenance New Roof Installation In terms of the design and installation of an original roofing system (in conjunction with the construction of a new building),
More informationRoofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.
Roofing Systems There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. BUR (Built-Up Roofing) Built-Up-Roofing, BUR is a roof that
More informationBLACK JACK ALL WEATHER ROOF COATING
PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.
More informationAfter the business decisions
After the business decisions have been made and the wet insulation and deteriorated deck have been identified, the real challenge of a comprehensive roof restoration the job of finding and repairing the
More informationRead and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS
AC TOPSEAL SELF-ADHERED, GRANULAR SURFACED, SINGLE PLY, LOW SLOPE ROLLED ROOFING 3 X 33.3 = 100 SQ. FT. 10 YEAR MATERIAL LIMITED WARRANTY For Use on Porches / Sheds / Utility Buildings / Accessory Buildings
More informationPlease read the entire document before purchasing and installing any of these products
Please read the entire document before purchasing and installing any of these products USA SBS UNDERLAYMENT ROOFING UNDERLAYMENT SBS Mineral Surfaced MINERAL SURFACE CAP SHEET Ice and Water Protection
More informationhttp://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wgevxqwtdqtkahqb3dx8wn...
Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wgevxqwtdqtkahqb3dx8wn... Page 1 of 2 8/3/2015 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats
More informationWATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
More informationCommercial Roof Systems Selection Guide
CertainTeed Commercial Roof Systems Selection Guide Good Better Best. Don't specify less. The chart below is a quick guide to choosing the right roof system for your needs. Please note: the best roofs
More informationMASTICS. 275 Centre St., Unit 15 Holbrook, MA 02343 (617) 996-0400. 15236 Shedd Rd. Middlefield, OH 44062 (440) 345-6900
MASTICS AQUAHALT MASTIC- A AQUAHALT MASTIC- A is a heavily consistent, trowel- applied mastic formulated with refined asphalt, fibers and solvent. It is designed as an all- purpose repair cement, it bonds
More informationTHE EFFECT OF REFLECTIVE ROOF COATINGS ON THE DURABILITY OF ROOF SYSTEMS
THE EFFECT OF REFLECTIVE ROOF COATINGS ON THE DURABILITY OF ROOF SYSTEMS Joseph W. Mellott II and Donald C. Portfolio ROOF COATING MANUFACTURERS ASSOCIATION International Roofing Expo TU-03 Technical March
More informationHow to repair your existing low slope flat roof.
How to repair your existing low slope flat roof. Recycled Rubber Roofing is not a "Roof Coating." It is a liquid emulsion used as the underlayment of a new or retrofit, built-up roofing system. One of
More informationHigh Performance Solutions and Compounds for Roofing and Structural Waterproofing
High Performance Solutions and Compounds for Roofing and Structural Waterproofing IKO is a worldwide group of companies with extensive experience and specialist technical knowledge. IKO is a leader in
More informationCertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs
CertainTeed Self-Adhering Roof Systems for Low Slope Residential Roofs Goes down fast. Stays on strong. Flintlastic SA performs in all the right ways. What s more important to you? Speed of installation,
More informationRECOATING AND RENEWING SPF ROOFING SYSTEMS
RECOATING AND RENEWING SPF ROOFING SYSTEMS Procedures, Regional Differences and type of coating systems Bruce Schenke Premium Spray Products REASONS TO RECOAT/RENEW Add a new coating layer to renew the
More informationNRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS The (NRDCA) has prepared this document to provide customers and installers information that the industry
More informationRoofing and Sealants. Contents. Section 6. 6.6.3 Single-ply membrane splicing cement. 6.0.0 Most frequently used types of roofing
Section 6 Roofing and Sealants Contents 6.0.0 Most frequently used types of roofing 6.0.0.1 Built-up membrane roofing 6.0.0.2 Fluid-applied membrane roofing 6.0.0.3 Single-ply membrane roofs 6.0.0.4 Metal
More informationWATERPROOFING FOR CONCRETE STRUCTURES
MANUAL OF CONTRACT DOCUMENTS FOR ROAD WORKS VOLUME 1 SPECIFICATION FOR ROAD WORKS SERIES 2000 WATERPROOFING FOR CONCRETE STRUCTURES Contents Clause Title Page 2001 General 2 2002 Protection of Bridge Deck
More informationCOMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE
www.epdmroofs.org COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE By Ric Vitiello President Forensic Roof Consulting and Hail Damage Assessment Training www.benchmark-services.com
More informationBUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION
07560 BUR BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION PART 1: GENERAL 1.01 SCOPE: To extend the useful service life of the aged or new asphalt built-up roof system and to reduce cooling
More information1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.
SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance
More informationSECTION 07550 - MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.
SECTION 07550 - PART I GENERAL 1.01 SECTION INCLUDES A. Vapor barrier (base ply); cover board at existing roof deck. B. Roof insulation at new roof deck. C. Modified bitumen membrane. D. Fluid applied
More informationSECTION 07530 SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.
SECTION 07530 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section includes the flowing: 1. Removal of existing roofing membrane. Existing bur roof has one overlay and penetration mastic is asbestos containing.
More informationColorado State University. Durrell Center Roof Repair
Colorado State University Durrell Center Roof Repair SPECIFICATION: POLYURETHANE FOAM ROOFING l.0 GENERAL REQUIREMENTS The successful application of a polyurethane foam roofing system is dependent upon
More informationNEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
More informationCOMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
More informationDurapax Coal Tar BUR Application Guide
400 Old Reading Pike, Suite 304 Pottstown, PA 19464 Tel: 610-579-9075 Fax: 610-323-0115 www.durapax.com Durapax Coal Tar BUR Application Guide DESIGN CONSIDERATIONS The proper specifications of any roof
More informationROOF ASSEMBLIES CHAPTER 9
CHAPTER 9 ROOF ASSEMBLIES SECTION R901 GENERAL R901.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. SECTION R902 ROOF CLASSIFICATION
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationCOMMERCIAL & LOW SLOPED ROOF SPECIALISTS TOTAL NDL SYSTEM MANUFACTURER WARRANTIES
C COMMERCIAL & LOW SLOPED ROOF SPECIALISTS We are equipped to handle the largest of your commercial roof needs. Whether storm damage or simply needing a new commercial roof due to age, Cobalt allows you
More informationSECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
More informationCITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
More informationRoofer On-the-Job Training Guide
Roofer On-the-Job Training Guide Roofers install and maintain built-up roofs, flat deck roofs, steep roofs and other roofs with a variety of covering materials. Training Requirements: 4500 hours (3 years)
More informationSECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
More informationTreatment of a surface or structure to resist the passage of water in the absence of hydrostatic pressure. presence of hydrostatic pressure.
Recommend Approval: Team Leader Date Division Chief Date Approved: Director Date Maryland Department of Transportation State Highway Administration Office of Materials Technology MARYLAND STANDARD METHOD
More informationCHAPTER 6 ASPHALT ROLL ROOFING
CHAPTER 6 ASPHALT ROLL ROOFING Section I. DESCRIPTION AND GENERAL DISCUSSION 6.1.1 General 6.1.3 Mineral-Surfaced Asphalt roll roofing is roofing in sheet form Mineral-surfaced roll roofing is composed
More informationRoofing Repairs 07511-1
SECTION 07511 ROOF AND FLASHING RESTORATION WITH TITLE 24 / COOL ROOF SURFACING PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the contract, including General and Supplementary
More informationSCOPE OF WORK PROVISIONS FOR ROOFER: ROOFER PITCH WORK IMPERIAL AND SAN DIEGO COUNTIES
STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL RELATIONS Office of the Director Research Unit 455 Golden Gate Avenue, 9 th Floor San Francisco, CA 94102 Edmund G. Brown Jr., Governor MAILING ADDRESS: P.
More informationFOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
More informationWaterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries Introduction Wastewater of petrochemical industries and refineries contains high amounts of emulsified aliphatic or
More informationFIRESTONE BUILT-UP ROOFING SYSTEMS APPLICATION GUIDE 3/14/2011
FIRESTONE BUILT-UP ROOFING SYSTEMS APPLICATION GUIDE TABLE OF CONTENTS 2.01.1 GENERAL......2 2.02.1 JOB SITE CONSIDERATIONS (CAUTION AND WARNINGS)...2 2.03.1 ROOF SUBSTRATE PREPARATION...2 2.04.1 WOOD
More informationPeel & Seal Self-Stick Roofing Solutions
Peel & Seal Self-Stick Roofing Solutions Ideal for Low Slope Applications Waterproof and Weatherproof Energy Efficient Tough and Durable Versatile, Effective Sealing Around Protrusions Perfect for Vents,
More informationMaintaining Your Roof
Maintaining Your Roof Roofs play a key role in protecting building occupants and interiors from outside weather conditions, primarily moisture. The roof, insulation and ventilation must all work together
More informationBITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC.
93-106 Revised March 2007 BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC. BITEC APM-4.5T is a torch applied, mineral surfaced,
More informationFinal inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
More informationFirestone Modified Bitumen Roofing Systems DURABLE. RELIABLE. SUSTAINABLE
Firestone Modified Bitumen Roofing Systems DURABLE. RELIABLE. SUSTAINABLE I n t r o d u c t i o n t o M o d i Acres of Roofing. Decades of Performance. Over the past 20 years, Firestone Building Products
More informationARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials
ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials SECTION 03 92 50 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings,
More informationThe existing roof angle change terminations and flashings when sound and intact can be reused.
January 2, 2015 Summary Specification Re-Skinning an Existing Roof Maintenance and Repair Warranty Upgrade for Up to 30 Years Re-Skinning Over an Existing Roof with a New C-EPDM Membrane Using The Existing
More informationFAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING. Asphalt Roofing Manufacturers Association
FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING Roofing Manufacturers Association Why is a built-up roof considered a multi-ply roof? ARMA defines a built-up roofing system as a roof where multiple
More informationSEAMS SEAMING USING SEAM TAPE
SEAMING USING SEAM TAPE SEAMS The membrane should be positioned so that the width of the seam is 3. Remove excess chalk from a chalk line by snapping the line into the air and then chalk a line one-quarter
More informationITEM 599.06060008 THERMOPLASTIC MEMBRANE ROOFING
DESCRIPTION Construct adhered membrane roofing system, roof insulation, and vapor retarder in accordance with these specifications. MATERIALS: General: Provide installed roofing membrane and base flashings
More informationFIRESTOPPING & SMOKE SEALS
SPECIFICATION SECTION 07 84 00 FIRESTOPPING & SMOKE SEALS 1 GENERAL 1.1 SECTION INCLUDES 1.1.1 Comply with Division 1, General Requirements and Documents referred to therein. 1.1.2 It is the intent of
More informationCONTINENTAL MATERIALS, INC. ALL-WEATHER APP INSTALLATION GUIDELINES
CONTINENTAL MATERIALS, INC. ALL-WEATHER APP INSTALLATION GUIDELINES Page 1 APP INSTALLATION GUIDELINES This guide provides instructions for the installation of CMI All Weather APP roofing materials. Any
More informationHOT ASPHALT BUILT-UP ROOFING SYSTEMS MORE LAYERS MEANS MORE PROTECTION
HOT ASPHALT BUILT-UP ROOFING SYSTEMS MORE LAYERS MEANS MORE PROTECTION ADVANCED TECHNOLOGY FROM OWENS CORNING TRUMBULL ASPHALT TruLo Lo Odor and TruLo Max asphalt raising the roof on asphalt performance.
More informationMinor Cracks in Horizontal Surfaces
Cracks, chips and broken or flaking areas in concrete are not only unsightly, they can lead to further deterioration of the surface. The result is a costly replacement project as opposed to a simple repair.
More information!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!
Table of Contents Section 1: Most Common Types of Flat Roofing Section 2: Better Understand Your Flat Roof Section 3: Flat Roofing Cost in 2015: Four Factors that Dictate Section 4: Planning A Flat Roofing
More informationBuilding Owners Guide to a Duro-Last System!
Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof
More informationIndefinite Quantity Unit Price Schedule
Indefinite Quantity Unit Price Schedule DCS # 08002 THIS SET OF BID FORMS IS FOR AREA 4 WORK DESCRIPTION Unit Unit Price Specification Number 2.1 WATERPROOFING & DAMPPROOFING 2.1 10 100 Pressure cleaning.
More informationPrices Effective April 1, 2016
Domestic U.S. Warranty Pricing Guide Longer term warranties have additional installation requirements and not all warranty terms are available for all roofing specifications. Please refer to the Firestone
More informationTHERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER
THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER DESCRIPTION TORCH OVER (15,17,19 YR) TH/BS-TH/CS 2 1 0 No 0. SUBSTRATE 1. THERMOTEK USA 2.0 FV TORCH SMOOTH 2. THERMOTEK USA PRO FP TORCH GRANULE COMPONENTS
More informationClear Fork Valley Local School District. Roofing Repairs Spring/Summer 2015
Clear Fork Valley Local School District Roofing Repairs Spring/Summer 2015 Instructions to Bidders: Public Notice To Bidders (ORC 3313.46) Notice is hereby given that sealed bids will be received at the
More informationHoliday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.
PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standing-seam metal roofing, custom fabricated. 1.2 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Show installation
More informationTHERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS
THERMOTEK SELF ADHESIVE MEMBRANE +G OVER DESCRIPTION SELF ADHESIVE OVER (8YR) BS-SA/CS 1 0 No 0. SUBSTRATE 1. BASE SHEET G FIBER GLASS BASE. THERMOTEK SELF ADHESIVE 3.0 FP GRANULE COMPONENTS AND WEIGHTS
More informationWaterproof Rooftop Balconies & Decks. Or How To Keep Your Ceiling Dry When People Walk On Your Roof
Waterproof Rooftop Balconies & Decks Or How To Keep Your Ceiling Dry When People Walk On Your Roof Overarching Concerns That Apply to All Walkable Decks Over Roofs Structure must be strong enough to support
More informationUSER GUIDE Easier, Safer, Betta! www.gripsetbetta.com WATERPROOFING
USER GUIDE Easier, Safer, Betta! www.gripsetbetta.com WATERPROOFING Welcome to Gripset Betta, Over the past 3 decades through the tireless commitment to improve and enhance the way buildings are waterproofed,
More informationSECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND.
SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND. 623.10.1 Description. This work shall consist of preparing the surface,
More informationROOFING PRODUCTS. www.resisto.ca INSTALLATION GUIDE FOR RESISTO. Time-tested premium quality products
INSTALLATION GUIDE FOR RESISTO ROOFING PRODUCTS 3 EAVES PROTECTION Time-tested premium quality products Whether you re building or renovating, RESISTO products offer effective solutions for preventing
More informationThe Harold J. Becker Company, Inc.
The Harold J. Becker Company, Inc. It is the mission of The Harold J. Becker Company, Inc. to deliver the absolute best possible quality product at the most efficient cost to our clients, while providing
More informationADDENDUM NO. 2. DATE: September 14, 2015 INVITATION FOR BID: IFB J160004535 Fire Station #22 Roof Replacement Project DATED: August 25, 2015
ADDENDUM NO. 2 DATE: September 14, 2015 INVITATION FOR BID: IFB J160004535 Fire Station #22 Roof Replacement Project DATED: August 25, 2015 RECEIPT DATE: September 30, 2015 (CHANGED) OPENING DATE: October
More informationAsphalt-Applied and Cold Application Built-Up Roofing Application Guide
1.0 General Information 1.1 The following section provides the application specifications currently available from Johns Manville (JM) for built-up roofing membranes and covers both hot asphalt and cold
More informationSECTION 07560 FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)
SECTION 07560 FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE) PART 1 GENERAL 1.1 DESCRIPTION 1. Fluid applied flexible acrylic waterproofing system over concrete. This work shall include the
More informationFlorida Building Code Approval
Florida Building Code Approval GAF-Elk Roof Underlayments Updated 10/13/09 Your Best and Safest Choice Quality You Can Trust Since 1886! Florida Building Code Online http://floridabuilding.org/pr/pr_app_dtl.aspx?param=wgevxqwtdqtbnbey5v%2boq...
More informationSTANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.
More informationtamko.com RESIDENTIAL ROOFING PRODUCT GUIDE
tamko.com RESIDENTIAL ROOFING PRODUCT GUIDE RESIDENTIAL ROOFING PRODUCT GUIDE SHINGLES / LAMINATED LIMITED DESIGN PRODUCT SPECIFICATIONS WARRANTY CERTIFICATIONS U.L. Laminated Shadowtone Choose From Classic
More informationUSER GUIDE Easier, Safer, Betta! gripsetbetta.com WATERPROOFING
USER GUIDE Easier, Safer, Betta! WATERPROOFING INDEX Welcome to the Gripset Betta Range Over the past 3 decades through the tireless commitment to improve and enhance the way buildings are waterproofed,
More informationSite Inspection Report
Site Inspection Report Project Title: 1 Canada Square Location: 1 Canada Square, Canary Wharf, London Date of Inspection: 16/05/12 System / Products: TBA (suggested flame free application) Attendees: G
More informationROOF ASSEMBLIES AND ROOFTOP STRUCTURES
CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1501 GENERAL 1501.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies, and
More informationCOMMERCIAL ROOFING. Learning Objectives. Commercial Roofing Fundamentals May 2, 2012
COMMERCIAL ROOFING The Fundamentals Firestone Building Products is a Registered Provider with the American Institute of Architects Continuing Education Systems. Credit earned on completion of this program
More informationResidential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...
More informationCrescent Valley High School Roof Investigation
Crescent Valley High School Roof Investigation Project: Corvallis School District Crescent Valley High School Roof Date: July 26, 2011 Report By: Rowell Brokaw Architects: Mark Young, AIA, Chris Andrejko
More informationAir-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
More informationDELTA Premium Moisture Management Systems for Foundations.
DELTA protects property. Saves energy. Creates comfort. DELTA Premium Moisture Management Systems for Foundations. DELTA Premium Moisture Management Systems provide the best protection for foundations.
More informationBest Practices in Roof Design: Sustainable Energy Efficient Reroofing
Best Practices in Roof Design: Sustainable Energy Efficient Reroofing Best Practice Roof Design: Sustainable Energy Efficient Reroofing Presented by Edis Oliver, PE Principal 9511 Lake Creek Parkway Austin,
More informationTHERMAL AND MOISTURE PROTECTION 07100. WATERPROOFING
DIVISION 7 THERMAL AND MOISTURE PROTECTION 07100. WATERPROOFING 07110. MEMBRANE WATERPROOFING: The following are minimum requirements to assure adequately designed waterproofed floors for machine and equipment
More informationDetached accessory structures that contain no conditioned floor area are exempt.
RESIDENTIAL ROOFING PERMITS: A roofing permit is required for roofing of residential dwellings and garages in accordance with Section R105 of the International Residential Code. Updated 11/2013 City of
More informationATLAS Roofing Products
ATLAS Roll Roofing Products World s Largest producer of roofing s Preferred by roofing professionals. Atlas has you covered on every part of the job, even what goes under your roofing. We are proud to
More informationFIRESTONE APP ROOFING SYSTEMS APPLICATION GUIDE TABLE OF CONTENTS
FIRESTONE APP ROOFING SYSTEMS APPLICATION GUIDE TABLE OF CONTENTS 2.01.1 GENERAL...2 2.02.1 JOB SITE CONSIDERATIONS (CAUTION AND WARNINGS)...2 2.03.1 ROOF SUBSTRATE PREPARATION...2 2.04.1 WOOD NAILER LOCATION
More informationSECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) 55-1 GENERAL The Contractor shall perform all work required by the plans for construction of pipe for storm drains, precast polymer trench drains
More informationtamko.com RESIDENTIAL ROOFING PRODUCT GUIDE
tamko.com RESIDENTIAL ROOFING PRODUCT GUIDE RESIDENTIAL ROOFING PRODUCT GUIDE SHINGLES / LAMINATED LIMITED DESIGN PRODUCT SPECIFICATIONS WARRANTY CERTIFICATIONS Metric Size Shadowtone Choose From Classic
More information