CO2 Alarm. Operation. Application



Similar documents
ACS-30-EU-EMDR-10-MOD

TMS TANK MANAGEMENT SYSTEM

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

WD-AMX Water Detection Controllers

600-GD & 600-GDL 600 SERIES GAS DETECTOR

TS510 & TS500. Installation & User Guide. Compatible Equipment

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

Fire & Security DETECTORS

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Advantium 2 Plus Alarm

CB200W Water Leak Detection Panel Application Guide

HM-W536 Install Guide

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

Combi B Alarm box. Mounting instructions

MIC-WKT and MIC-WKT-IR

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

HERZ-Thermal Actuators

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

T5000 T000 LCD Digital Fan Coil Thermostat

Fire Pump Controllers Remote Alarm Panels

Problem / Solution. The problem:

DCP Fan Controller. Version 01/2009. The engineer s choice

UM-X Field display for continous level sensors

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

GAE953 Electrical Alarm Unit 19" with Indicator

Heating Controller. Building Technologies HVAC Products

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

Drayton Digistat +2RF/+3RF

RRV934. Multi-controller. Synco living

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

AlarmSense 2-wire detection and alarm system. Product Guide

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

, User s Manual

OCTOPLUS WARNING AND MEASUREMENT CONTROL UNIT FOR TOXIC AND FLAMMABLE GASES

How To Test A Power Distribution Unit

Floodlight Range Installation Guide

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Electronic Control Devices The European Product Catalogue 2007

Mureva Assembly surface mounted wiring devices

9448 Installation and User Guide

Operating Instructions

Product and functional description

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8

Model: DC-A2IO Advanced HVAC Controller

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

Heating and Hot Water Services Controls General Technical Specification

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P

User and installation manual

Universal control module for motorized devices

SMART SENSOR COLLECTION

Installation Guide for Hive Active Heating

Operating instructions IV / 2007

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Network Time Accessories LED CLOCK. (for NTP Synchronization)

MICROPROCESSOR BASED DIGITAL ALARM SYSTEM

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Y7230A CO 2 Alarm System

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

Water Leak Detection System

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Operating and Maintenance Instructions MEDIPOINT 125 MEDICAL GAS CENTRAL ALARM

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Operating & Maintenance Manual. Alert-2 Microprocessor Based Digital Alarm System v5.9

How To Use A Power Supply On A Powerline 2.2 (Ai)

9452/9453 Installation and User Guide

Modular I/O System Analog and Digital Interface Modules

GST301. (Single Protection Zone) Operation Manual

Inwall Room Temperature Unit

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

HCE80/HCC80/HCE80R/HCC80R

User Manual THR840DUK Digital Thermostat

TS93 EMR T/PT/TDE. Surface applied door closer

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

DTW Works Master Specification Version 2006

GREISINGER electronic GmbH

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ADM1TE 5/30A DIN rail single phase two wire energy meter

SYSTEM 45. C R H Electronics Design

T7560A,B,C Digital Wall Module

Conventional Fire Detection and Extinguishant Control System Specification

Ammonia Detection System Codes and Design Specifications

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Transcription:

CO Alarm 100-77V AC Supply Voltage Two pre-configured alarm and control thresholds Thresholds factory set to customer requirements on dispersive infrared sensing technology Optional internal audible alarm Digital display of carbon dioxide levels (ppm) Alarm status indicator lights Sensor fault indication Application The Duomo Carbon Dioxide Alarm has been developed to control and protect against the build up of carbon dioxide in environments where ventilation is essential to occupant safety and comfort such as; commercial catering establishments, science laboratories, classrooms, offices, cellars and more. This is a wall mounted, stand alone carbon dioxide alarm. It has two thresholds which can be preconfigured to switch the two on board alarm relays at any required level of carbon dioxide up to 10,000 ppm. Control and alarm threshold levels may vary. At Duomo we can configure the switching points to suit your personal preference. Operation When carbon dioxide levels rise to alarm threshold one an output at the supply voltage (100-77V AC) is generated. This is usually used for automatic ventilation control or remote alarm indication. The second relay changes over if carbon dioxide levels continue to rise. The second alarm contact can be used to either break the circuit to a combustion control or, in the case of commercial kitchens, break the supply to the gas safety shut off valve. At the second alarm threshold the audible alarm will sound (if fitted). The CO Alarm has an onboard digital display, alarm status indicator lights and optional audible alarm. i Carefully read the following instructions prior to installation of this device. Always keep this pamphlet for future reference. Always isolate the electrical supply before opening.

Installation Instructions The Duomo CO Alarm can be mounted on a standard double back box. To fit the enclosure it is necessary to remove the power module and the printed circuit board (PCB) (see Page 4).To open the enclosure see page 3. Fix the empty enclosure to the double socket back box (not included) then screw the power module back into position and click the PCB into place. Connect the electrical supply voltage; 30V AC live () to terminal A and neutral to terminal B. The first alarm terminal C becomes live in alarm. Therefore it can be connected to a remote audible flashing alarm e.g. the Duomo AF16. Alternatively this alarm level can be lowered to provide a comfort control output to open vents or boost fans etc. This level can only be adjusted by Duomo engineers prior to despatch. See model selection guide on page 6. The second alarm terminals D and E break the circuit in alarm.this pair of terminals are volt free so can be used to isolate the electrical supply to a gas valve. This alarm can also be configured to close in alarm. Again this modification can only be made by Duomo engineers prior to despatch. See model selection guide on page 6. Wiring Diagram www.duomo.co.uk AL1 Pe CO ALARM IPUT: 100~77V A.C. 50/60Hz. AL1: OUTPUT C 10A@50VAC. AL: D AD E 10A @ 77VAC. A B C D E Al 1 Fused and isolated 100-77V AC supply AL* Second alarm volt free contact * OTE: AL may break or make in alarm depending on your order. Carbon Dioxide Alarm Layout & Dimensions Key 15 450 ppm 1 1.. Digital display of parts per million carbon dioxide in air. Sensor fault indication. 3 3. Alarm status indication; Green = Safe Red&Green= Alarm 1 Red=Alarm 158 4

How To Remove The Enclosure Lid ote:turn off the power to this unit before opening the enclosure 30V FUSED AD ISOLATED SUPPLY ote: See FP45 wiring datasheet L1 ote: See FP45 wiring datasheet L1 TRIO GAS SAFESTART KS AUTOMATIC COTROL IPUT TERMIAL PLUG E E GD 1 EXTERAL LIMITS (EMERGECY STOP P.B., FIRE ALARM, ETC.) 30V AC POWER SUPPLY SUPPLY VETILATIO CURRET MOITOR 1 L1 L FP45 CURRET MOITOR 1 L1 L FP45 CURRET MOITOR 4 6 10 4 6 10 EXTRACT VETILATIO CURRET MOITOR IPUTS 4V dc 10mA MAX. 3 4 OUTPUTS 3A MAX 50Vac PF = 100% RU 5 6 OUTPUT TERMIAL PLUG L 7 8 L 9 10 L 11 1 13 14 WATER VALVE (IF FITTED) 3 1 4 P GAS PRESSURE SWITCH G61 WEEP BYPASS ASSEMBLY GAS - WEEP VALVE GAS - MAI VALVE D A B C 30V AC POWER SUPPLY E DUOMO CARBO DIOXIDE ALARM Alarm contact (opens in alarm) Alarm 1 contact (closes in alarm) Remote audiovisual alarm beacon VOLT FREE STATUS RELAYS FAIL 15 16 POWER 17 18 Commercial Kitchen - Typical connection with KS Trio and current monitor ventilation proving

Carbon Dioxide Alarm Internal Arrangement To remove the power module unscrew the fixings shown To release the PCB carefully push the retainer in the direction shown (see picture to the left) until it unclips. The board can then be withdrawn from the enclosure. Fixing positions and cable entry point ote: These fixing points are compatible with single and double gang back boxes. Recommended cable type is tri-rated 1mm cross sectional area (csa).

Operating Instructions The Duomo Carbon Dioxide Alarm has two alarm thresholds. These are configured prior to despatch from Duomo to suit customer requirements (see last page for order form). The default settings are for a commercial catering establishment.they are as follows; Alarm 1 on @ 800ppm - Alarm 1 off @ 500ppm Alarm on @ 5000ppm - Alarm off @ 4500ppm When power is applied to terminals A and B, the green light will illuminate and the digital display will show all symbols. This display will then change to HEAT for approximately 5 seconds. The display will then change to read the current ambient levels of carbon dioxide in the air. Alarm 1 (Terminal C) This output becomes live at the supply voltage when the pre-set threshold is reached. This output can be connected to a vent opening device, ventilation fan or a remote alarm indicator. There is no on-board audible alarm associated with this output. The status of the alarm is indicated by the green light flashing red and green alternately.this alarm output will stop when the levels of carbon dioxide drop below the alarm off threshold. Alarm (Terminals D and E) Available with either a normally open or normally closed contact. This contact actuates should levels reach the second alarm threshold.this contact is rated at 10 A at 77V AC.The purpose of this alarm is to break the ciruit to the gas supply valve or make the circuit to sound remote alarms. This alarm will reset when the levels of carbon dioxide drop below the level alarm off threshold. 5000 4500 4000 3500 3000 500 000 1500 1000 Carbon Dioxide Levels (ppm) Alarm 1 off Alarm 1 on Alarm 1 off Time Alarm 1 on Alarm 1 and on Alarm 1 on Guarantee This device is guaranteed for a period of 3 years from the year of production. Conditions; Substitution or repair free of charge of any component recognised as being faulty from production. The unit must be delivered to the resaler or directly to Duomo. ote: All wiring must comply with relevant local electrical standards. The installation of this product should only be undertaken by qualified personnel. Duomo (UK) Ltd will not be held responsible for any damage to property or personnel resulting from incorrect installation. If you are in any doubt regarding the installation or function of this product please call our Technical Department on 01905 79746.

CO Alarm Model Selection Carbon Dioxide Alarm Carbon Dioxide Alarm Levels Alarm 1 on at ppm Alarm 1 off at ppm Alarm on at ppm Alarm off at ppm Alarm actuation method Make in alarm Break in alarm M B Audible alarm With audible alarm o audible alarm A - ame: Company: Contact no.: Please complete this order form and fax it back to us on 01905 77496.