Three phase connection



Similar documents
Medium-voltage Transformers

SUNNY TRIPOWER 5000TL 12000TL

Sunny Boy Accessories SMA POWER BALANCER

Technical Information Short-Circuit Currents Information on short-circuit currents of SMA PV inverters

Planning Guidelines SMA FLEXIBLE STORAGE SYSTEM WITH BATTERY-BACKUP FUNCTION

PID - The Problem and How to Solve It

Monitor Simply and Securely

CHANGING THE WORLD WITH COMPELLING IDEAS. German Indian Renewable Energy Dialogue 1st of October 2008

TechnologyCompendium 3.4. PV Grid Integration. Backgrounds, requirements, and SMA solutions

Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK

Grid Integration of Photovoltaic (PV) Systems

How To Make A Fronius Cl Power Inverter

SMA Bluetooth. Content. SMA Bluetooth Wireless Technology in Practice. Further Documents on SMA Bluetooth

Size template. Grid Connection Masterclass Energex John Lansley Senior Network Solutions Engineer

Sunny Family 2012 PRODUCT CATALOG

Romana Brentgens / photon-pictures.com (2)

Simple and secure monitoring

Designing PV Plants Optimised for Economic Efficiency

Criteria for Selecting a Residual-Current Device

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance

How To Use The Sunny Central Communication Controller

Anti-blackout system for grid connected solar installations (Solsafe concept)

Fronius IG Plus. The next generation grid-connected PV inverter

Technical Information Requirement for MV transformers and transformer for internal power supplies for SUNNY CENTRAL

Commercial Outlook for Solar Power Generation

4KVA/5KVA Parallel Installation Guide

System Monitoring SMA Safety and Password Concept for Password-protected PV Plants with Bluetooth Wireless Technology

Advisory Guide. Decentralized Inverter Technology in Large-Scale PV Plants. String inverters. Technical Information Edition1.1 BL-DezWT-UEN103511

Rule Fast Track Analysis for National Life Insurance Co.

Photovoltaic Solar Energy Unit EESFB

SUNNY BOY 2000HF / 2500HF / 3000HF

Issue 06 / StoraXe Home & Small Business Battery storage systems for professionals

PV And Storage: Solutions with Potential

FUNCTIONS AND CAPABILITIES OF PV INVERTERS TO BE PART OF A SMART GRID

Sunny Boy SB 700. String Inverter 700 W, grid-tied operation, grid frequency 777,00 50 Hz / 60 Hz auto-detection SB 1100LV

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

THREE PHASE CIRCUITS

Fronius IG Plus. The next generation grid-connectedpvinverter.

Ontario Electrical Safety Code 25 th Edition/ 2012

46120-F0 Solar Energy Training System

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

/ The allrounder with maximum yield. / WLAN interface / Smart Grid Ready

Solar Solutions and Large PV Power Plants. Oscar Araujo Business Development Director - Americas

SMA Solar Technology AG Analyst / Investor Presentation Quarterly Financial Report January to September 2008

Solar Energy. Energy is here

N.J.A.C. 14:8-4 NET METERING FOR CLASS I RENEWABLE ENERGY SYSTEMS

Installation Guide Solar Connect-11

FIT TIER 2 Application

Consumer Products Services Germany GmbH Türkheim Germany

Current Transformer (CT) Selection Guide

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

Accessories SUNNY REMOTE CONTROL

PV Inverter SUNNY TRIPOWER 8000TL/10000TL/12000TL/15000TL/17000TL

Operating Manual POWER PLANT CONTROLLER

sma FlexIble storage system

Technical Information Battery Management of the Sunny Island Gentle charging control for lead-acid batteries based on current state of the battery

SA Power Networks Planning for Solar PV? Customer information guide to network connected solar PV inverter systems

Training Systems for Renewable Energies. Acquiring Practical Skills and Project-oriented Expertise

Grid Connected Storage Various Applications Realised with Proven Technologies. Wilhelm van Butselaar Clean Energy Week 2013, Brisbane July 2013

Inverter / Charger Installation General Operations and AC and DC Connections

Innovation Powers Efficiency

Figure. 1 - Split Phase 240/120V circuit (180 phase shift)

One. Invest with confidence Smart Solar Inverter Solutions. solarinvertersolutions.com. Residential, commercial and large scale applications

A favorable investment in solar power

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

SURGE PROTECTIVE DEVICES

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

SUNNY BEAM USB Driver Installing the Sunny Beam USB Driver. 1 Sunny Beam USB Driver. Version: 1.4

Isolated-Parallel UPS Configuration

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Distribution Operations with High-penetration of Beyond the Meter Intermittent Renewables. Bob Yinger Southern California Edison April 15, 2014

Installation and Operating Manual

Reverse-feed applications for circuit breakers

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Trainers. Target Groups of Participants. General background

VOLTAGE CONTROL IN DISTRIBUTION SYSTEMS AS A LIMITATION OF THE HOSTING CAPACITY FOR DISTRIBUTED ENERGY RESOURCES

Configure Inverter output for two utility settings, (1)120V/60Hz, (2)220V/50Hz

Yield Reduction due to Shading:

Technical Information POWER PLANT CONTROLLER

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

DAVID WILSON LIBRARY

ABB central inverters PVS to 1000 kw

Visualization and remote access for small and medium-scale PV plants. Be a solar expert

TERMS AND CONDITIONS

SMA Solar Technology AG - Results For First Quarter 2010

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

2.5 MegaWattBlock for Solar Power Plants

SRS2025. Home & small Business. Energy Storage Solution

Register of Completed Embedded Generation Projects (Non-registered, typically 30kW to 5000kW)

ABB Inc. April 19, 2011 Slide 1

Central Inverter Planning of a PV Generator

Roy Allen, Technical Training, 17FEB2015 ABB Solar Days Residential Products, Design & Application Rapid Shutdown. ABB Feb 27, 2014 Slide 1

emobility WAGO Leading the Charge

Connecting and operating storage units in low voltage networks

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Transcription:

Three phase connection with SUNNY MINI CENTRAL Contents The inverters of the Sunny Mini Central product family have been especially conceived for their use in threephase feed-in systems. This technical information contains important material on the symmetrical grid operation of these systems as well as on the requirements which have to be taken into account during their design. NetzSMC-UEN084110 Version 1.0 1/6

Connection Principle 1 Connection Principle By joining three Sunny Mini Centrals into a group, a three-phase feed-in system can be established which takes the country-specific limits for unbalanced loads unto account 1. If, when considering the unbalanced loads, a distinction is made between a design based on the assumption of fault-free operation 2 and a design which assumes the possibility of a fault 3, or if more protective measures are needed in the case of particular installations, additional requirements for the system could arise. In order to react with flexibility to the requirements of the utility operator as well as to the regulations in force in the country where the system will be implemented, all Sunny Mini Centrals are equipped with the innovative Power Balancer. With it, three inverters can be connected to each other respectively. This way, a three-phase "unit" is formed which, technically, is no different from a three-phase inverter. 2 Regulations in Germany In Germany, the following regulation must be met when designing a system or when connecting it to the grid: VDEW regulation Power-Generating Systems on the Low-Voltage Grid, March 2004, 4th amended edition. The following requirements for connection to the grid follow from this regulation: Systems up to 30 kva The unbalanced load in the normal operation (4.6 kva) must be observed. The Power Balancer is not needed. A disconnection point which is accessible at all times is not necessary. Single-phase inverters can feed in independently from each other. An external ENS is not necessary. The individual ENSs of the inverters are approved. (ENS = Gridmonitoring device with its all-pole circuit breakers in series.) Example: a 30 kva PV system with 3 x Sunny Mini Central 10000 TL is possible, without the Power Balancer. 1 Total asymmetry between the external conductors. 2 System design which assumes fault-free operation 3 System design which considers the possibility of a fault: "Fehlerfall". SMA Solar Technology AG 2/6

What to do, when additional measures are required? Systems > 30 kva The unbalanced load in the normal operation (4.6 kva) must be observed. A disconnection point which is accessible at all times is necessary. A three-phase voltage monitor with overvoltage and reverse current protection and a circuit breaker is needed: By creating the feed-in units and activating the Power Balancer function (operating mode in Phase Guard or Fault Guard), a three-phase voltage monitor for every feed-in unit can be implemented. Additional operational safety is achieved through the internal circuit breaker, the function of which is tested before every starting procedure. By arrangement with the utility operator, an externally implemented "three-phase voltage monitor with circuit breaker" can be dispensed with, under certain circumstances. Example: a 99 kva PV system with 3 x 33 kw feed-in units. Each unit consists of 3 x SMA 11000TL; the 3-phase quality is achieved by the Power Balancer through the electric connection of the inverters. 3 What to do, when additional measures are required? When seeking a permit for a PV system, the technical connection requirements (TCR) of the appropriate utility operator must be observed, in addition to the applicable state regulations in the country of installation. In these situations and under certain circumstances different declarations or interpretations can lead to difficulties in obtaining the permit for the system. The activation of the Power Balancer function can be of aid in these cases. Through the activation, the following fundamental system properties are achieved: "Three-phase quality": this is achieved throught the electrical connection of three single-phase inverters into a three-phase feed-in unit. "The highest operational safety": by means of the "Fail-safe operation", the entire feed-in unit is switched off, or the feed-in is reduced to the highest unbalanced load allowed, if there is an unintended interruption in the electrical connection between the partial systems. Additional flexibility is afforded by the different operating modes of the Power Balancer. Here, the reaction of the feed-in unit to grid or device failures can be tailored to the corresponding utility operator's requirements. SMA Solar Technology AG 3/6

What to do, when additional measures are required? The Power Balancer's operating modes can be placed in the following four levels: Phase 1 Feed-in unit with systems independent from one another, operational mode "off" The feed-in of the unbalanced load in case of an error is possible, since feed-in continues in the phases not affected. Phase 2 Minimal yield losses in case of error. Feed-in unit with Power Balancer in "Power Guard" operating mode. In case of grid error or a device failure the feed-in unit continues to feed a maximum of 5 kva in the phases not affected. Phase 3 The unbalanced load is limited to a maximum of 5 kva. Feed-in unit with Power Balancer in "Phase Guard" operating mode. The Power Balancer substitutes a three-phase voltage monitoring. Phase 4 As in the case of external voltage monitoring, disconnection of the feed-in unit only takes place in case of grid errors. Feed-in unit with Power Balancer in "Fault Guard" operating mode. Appearance of an asymmetrical feed-in is avoided by means of immediate disconnection of the feed-in unit, in case of grid error (three-phase monitoring) or device failure. An advantage when compared to externally implemented voltage monitoring is that an unbalanced load will not be generated even in the case of a device failure. An external solution can only detect grid errors. Three-phase feed-in unit with electrical connection through the Power Balancer By using a multitude of the feed-in units mentioned above, large systems in up to the Megawatt range with symmetrical grid operation can be achieved. SMA Solar Technology AG 4/6

What to do, when additional measures are required? How is the Power Balancer activated? Device connection The Power Balancer function is already integrated in all Sunny Mini Central units. For this purpose, all the inverters are equipped with an internal terminal connection, with which three devices in each case can be connected with a simple communication cable. In this case one of the inverters must be configured as "master" (jumper). The new SMC 9000TL-10/10000TL-10/11000TL-10 are fitted with a plug system for connection. The electrical connection of three devices is carried out in the case of these inverters using a prefabricated connection cable (order number PBL-YCABLE-NR). The designation of a "master" is not necessary here. Activation of the desired operating mode The behavior of the three-phase feed-in system in case of a device failure or grid error can be determined by an installer by means of operating parameters. These adjustments can be carried out using SMA Solar Technology communication products. An additional password offers more security here. You can find more information in the documentation of your Sunny Mini Central and in the "Declaration on three-phase voltage monitoring by means of the Power Balancer", Source: www.sma.de. SMA Solar Technology AG 5/6

References 4 References Title image: Gehrlicher Solar AG "Ecoparque Solar de Bullas" (5 MW): Largest CdTe thin-film system in Spain. 250 three-phase feed-in units made up of 750 Sunny Mini Central 7000HV inverters. Images: SMA Solar Technology AG "Energiepark Fünfstetten", Fünftstetten (1.67 MWp): The largest PV system using silicon thin-film technology. 27,945 Kaneka K60 thin-film modules and 228 Sunny Mini Central 6000A inverters Operator: Erstes Bürgersolarkraftwerk Fünfstetten GmbH & Co. KG Planning and implementation: IBC Solarstrom Verwaltungs GmbH, IBC Solar AG Images: Schletter Solar Montagesysteme GmbH PV system on the Schletter company building (1.33 MW): 18,298 thin-film modules and 109 Sunny Mini Central 11000TL inverters. SMA Solar Technology AG 6/6