Product Catalogue August 2015. Energy management Switches and controls



Similar documents
EBDSPIR-PRM, EBDSPIR-PRM-IP

EBDSPIR-DD, EBDSPIR-DD-IP

Lighting Management solutions

Operating instructions II / 2004

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

5W LED Energy Saver PIR Bulkhead

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

Quantec Wiring Instructions

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

5YR. Advanced LED lighting. High performance industrial lighting. 50% energy against traditional fittings Up to 75% energy saving with sensing

Emergency voice communications Product Name

Fused Spur Time Switch

Drayton Digistat +2RF/+3RF

APPLICATION GUIDE MINI PRODUCT GUIDE

FIREDEX Conventional Fire Panels

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

Power Socket (2 Gang)

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Operating instructions IV / 2007

Industrial Linergy LED

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

Medical Lighting. XL4 Patient Light

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

ABB i-bus KNX Security Solutions with KNX Security Terminal Product Information

Fire Alarm System Plans Review Checklist Property location Date of Review

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Wiring diagrams for luminous 1P 1-way switches with 110 V~ or 250 V~ signalling units

Fire. The Fire Installers Mate. A guide to fire alarm systems design

15 Series - Electronic step relay and dimmer. Features SERIE

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

Rogers Smart Home Monitoring QUICK START GUIDE ROG_6093_QST_GDE_EN.indd 1 9/22/12 8:29 AM

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

BS5839 Part 1:2002 Overview

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

500r+ Installation and User Guide

Solid as a rock Soliroc

C-Bus Solutions. Complete commercial control. Make the most of your energy SM

V94 BULK TAPE DEGAUSSER

Wireless Home Security Alarm System AM 500

Repeaters and Mimics Data Sheet

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Robust and waterproof

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

Digital Keypad Use s Manual

I.S :2013 Fire Detection & Alarm Systems

ELECTRIC CENTRAL HEATING FLOW BOILER

User Manual THR840DUK Digital Thermostat

Innovative DOOR STATION Solutions

Passive Infrared Motion Detector 5420/90. Installation Instructions

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Conventional Fire Detection and Extinguishant Control System Specification

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

High Bay Occupancy Sensor Selection Guide

bulkhead luminaires distributed by distributed by EXCLUSIVELY EXCLUSIVELY Available throughout 420 Branches Available throughout 420 Branches

SFERA. NEw. 2 wire. audio ViDEO PUSHBUTTON PANELS

600-GD & 600-GDL 600 SERIES GAS DETECTOR

Stove Guard Kit User Manual

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

Unica for KNX system 226

in a new light. Occupancy sensors and sensor lights. Sleek new styling and more features than ever before.

Installation Instructions

GUARDIAN REFUGE & EMERGENCY VOICE COMMUNICATION SYSTEMS

id led 4" square housing FL44

KNX Lighting Control System

SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

ST815 Illumination Sensor with LCD

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

Smart Sensing Solutions Since 1954

How To Use A Power Supply On A Powerline 2.2 (Ai)

RGB Light Panel Applications. RGB LED Light Panel FEATURES & BENEFITS SPECIFICATION SHEET

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

7 Lighting Technology

PIR Motion Detector INSTALLER GUIDE E-700. SF-SA-140 -B.qxd 16/05/ :19 Page 1

Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE

CB200W Water Leak Detection Panel Application Guide

I.S :2013 Fire Detection & Alarm Systems

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15

ACS-30-EU-EMDR-10-MOD

ACTIVE 5 ENGINEERING MANUAL

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810

Industrial Batteries / Motive Power Chargers 2100.NET.»For improved efficiency and durability«

PRESENCE DETECTOR PD-C360i/24 KNX ECO (EP )

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

FACTORY AUTOMATION EXPERTISE AND SERVICE OPEN DOORS RADAR SENSORS FROM PEPPERL+FUCHS

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

basicdim DGC Compact control module

Transcription:

Product Catalogue August 2015 Energy management Switches and controls

Energy management Switches and controls Introduction Range overview Timers & Outdoor timers & Technical section Cable glands & terminal blocks Aquasafe Technical section Index Chapter 10 1 2 3 4 5 6 7 8 9 10 Chapter 11 Chapter 12 Chapter 13 Chapter 14 Chapter 15 Chapter 16 Chapter 17 Chapter 18 Elkay Elkay Product Catalogue LIT-057GB 08/15 08/151/11

Introduction Introduction Carbon footprint 1/2 Energy survey 1/3 Product applications 1/4 1 Elkay Product Catalogue LIT-057GB 08/15 1/1

Introduction Carbon footprint 1 Climate change is a serious problem that affects us all. There is now an overwhelming body of scientifi c evidence that emissions of greenhouse gases are changing the world s climate. Reducing energy consumption therefore not only saves money, but also will reduce our carbon footprint. The new Energy Range from Elkay provides a cost effective practical step along this important journey. Backing up the science, the UK government passed the Climate Change Act 2008 which introduces the world s first long-term legally binding framework to tackle climate change. The Act aims to encourage the transition to a low-carbon economy in the UK through legally binding emissions reduction targets. This is enforced by EU Energy Performance Directives, which now stipulate key areas for improvement in the energy performance of buildings. The new Elkay Energy Range gives architects, planners and electrical contractors a broad selection of simple but highly effective solutions to minimise the amount of energy used in all types of commercial and industrial environments. In a domestic setting, the Elkay Range gives an excellent opportunity to increase style and functionality around the home, whilst making an important contribution to the reduction in our carbon footprint at the same time. 1/2 Elkay Product Catalogue LIT-057GB 08/15

Introduction Energy survey 1 Businesses of all sizes have never been more aware of the need to reduce energy consumption. Mention the spiralling costs of fuel all of which contribute to make reducing energy consumption a necessity rather than a luxury. But where do you begin? How can you be sure you re cutting costs not corners? After all you re in business to make a profit and cannot afford to cut energy consumption at the expense of running your business. To reinforce these findings, one nationally known UK retailer has cut their energy bill for lighting in back room areas by a massive 87 percent at just one of their branches after implementing the recommendations made in their energy survey. To find out more about Elkay Energy Surveys or to arrange one for your business call 01675 468232 or email techinfo-elk@tnb.com This is where Elkay can help. Decades of experience in energy management have given us the expertise to come into your organisation and carry out a complete audit of your energy expenditure. When we undertake an Energy Survey, we ll tell you not only where you are wasting energy but recommend practical steps, by utilising the Elkay Energy Range, to reduce waste and tell you exactly how much you ll save - in terms of energy output and money. It s a service which many blue-chip companies have already taken advantage of - and the savings can be staggering. Elkay Product Catalogue LIT-057GB 08/15 1/3

Introduction Product applications 1 350A-1 Pushbutton Timer 374B-1 Ceiling PIR Office corridor Visitor s parking Warehouse Cleaning cupboard Ladies toilet Mens toilet Reception Stairwell Disabled toilet Lobby Open plan office Stairwell Stairwell Meeting room Storage Canteen 4 5 7 9 Warehouse office Director s parking Smoking area Staff entrance Outdoor area 560A-1 Outdoor Touch Timer 1/4 Elkay Product Catalogue LIT-057GB 08/15

374B-1FPC Fireproof Ceiling PIR 1 380A-1 Microwave Sensor Office Office Office Office Open plan office Meeting room Corridor Fire exit Factory warehouse Delivery bays 374B-1 Ceiling PIR 380A-1 Microwave Sensor Parking Parking 370B-1 3 wire wall PIR Elkay Product Catalogue LIT-057GB 08/15 1/5

Energy management Range overview Range overview Timers & - Technical specification 2/2 Outdoor timers & - Technical specification 2/4 2 Elkay Product Catalogue LIT-057GB 08/15 2/1

Range overview Timers & - Technical specification 2 Columbus Type Columbus Timer Columbus Timer Electronic Timer Pushbutton Timer Pushbutton Timer Reference 400A 400A-3 400E 350A-1 3875A-1 Configuration Single contacts Double contacts 2 Wire 3 Wire Colour White White White White White Hidden Screws Fascia Plate Height 10 mm 10 mm 10 mm 8 mm 8 mm Back Box Depth (Not supplied) 10 mm 10 mm 10 mm 25 mm 25 mm Max Load Rating @240V Resistive / Incandescent 6A 6A 2A Max Load Rating @240V Fluorescent 3A (max 6 fittings) 3A (max 6 fittings) 2A (max 6 fittings) Max Load Rating @240V Compact Fluorescent 3A (max 6 fittings) 3A (max 6 fittings) 2A (max 6 fittings) Max Load Rating @240V LED 3A 3A 2A Blue Locator Ring Red Signal LED Neutral Required Timing Range 5sec - 5min 5sec - 5min 20sec - 25min 2min - 2h 2min - 2h Timing Cancellation Illuminated Switches Intelligent Power Search Facility N/A Use with Contactor ** Section 3 / Page No. 3/4 3/4 3/4 3/5 3/5 PIR Slave Standard PIR Standard PIR Type PIR Timer PIR Timer Electronic Timer Timer Timer Reference 376A-1 370A-1 376A-3 370B-1 376B-1 Configuration 2 Wire 3 Wire 3 Core connection 3 Wire 2 Wire Colour White White White White White Hidden Screws Fascia Plate Height 8 mm 8 mm 8 mm 8 mm 8 mm Back Box Depth (Not supplied) 25 mm 25 mm 25 mm 25 mm 25 mm Max Load Rating @240V Resistive / Incandescent 10A 10A Max Load Rating @240V Fluorescent 10A 10A Max Load Rating @240V Compact Fluorescent 10A 10A Max Load Rating @240V LED 10A 10A Blue Locator Ring Red Signal LED Neutral Required Sensitivity Control Timing Range 2min - 1h 2min - 1h 2min - 1h 2min - 1h LUX Level Adjustment Timing Cancellation Illuminated Switches Intelligent Power Search Facility N/A N/A Use with Contactor ** ** Section 3 / Page No. 3/6 3/6 3/6 3/6 3/6 NOTE: 3 Wire products have a neutral. 2 Wire products have no neutral. Slaves must be used with illuminated and connected with 3 Core cables to Master unit 2/2 Elkay Product Catalogue LIT-057GB 08/15

Pushbutton Standard Standard Pushbutton Slave Long Timer Pushbutton Timer Pushbutton Timer Touch Timer Touch Timer Touch Slave 350A-3 3875A-1-LT 350B-1 3875B-1 360A-1 2235A-1 360A-3 3 Core connection 3 Wire 2 Wire 3 Wire 2 Wire 3 Wire 3 Core connection White White White White White White White 8 mm 8 mm 8 mm 8 mm 8 mm 8 mm 8 mm 25 mm 25 mm 25 mm 25 mm 25 mm 25 mm 25 mm 10A 10A 10A 10A 10A 10A 10A 10A 8min - 8h 2min - 1h 2min - 1h 2min - 2h 2min - 2h N/A N/A N/A N/A ** ** ** 3/5 3/5 3/5 3/5 3/6 3/6 3/6 Ceiling Mount Fireproof Ceiling PIR Timer Mount PIR Microwave Timer Remote Timer Mount Box Wall Surface Wall Spacer Plate capacitor 374B-1 374B-1FPC 380A-1 320A-1 210A-1 220A-1 PFCC-1 3 Wire 3 Wire 3 Wire 3 Wire White White White White White Black N/A 4 mm 4 mm 8 mm 8 mm N/A 55 mm 92 mm 35 mm 25 mm 25mm 10mm N/A 10A 10A 4µF 10A 10A 4µF 10A 10A 4µF 10A 10A 4µF N/A N/A N/A N/A 2min - 1h 2min - 1h 2min - 2h 2min - 2h N/A N/A N/A N/A N/A N/A N/A ** ** ** ** ** 3/7 3/7 3/8 3/9 3/9 3/9 3/9 *PFCC-1 Capacitor will often be required with circuits switching low wattage loads **PFCC-1 Capacitor must be fitted at contactor - see Section 3/15 or contact Elkay Technical NOTE: Slaves must be used with illuminated and connected with core cables to Master Unit. Elkay Product Catalogue LIT-057GB 08/15 2/3 2

Range overview Outdoor timers & - Technical specification 2 Standard Standard Type Pushbutton Timer Pushbutton Timer Pushbutton Slave Pushbutton Timer Pushbutton Timer Reference 550A-1 550A-3 550A-5 550B-1 550B-3 Configuration 3 Wire 2 Wire 3 Wire 2 Wire Colour White White White White White Hidden Screws Fascia Plate Height 8 mm 8 mm 8 mm 8 mm 8 mm Back Box Depth 65 mm 65 mm 65 mm 65 mm 65 mm Max Load Rating @240V Resistive / Incandescent 10A 10A Max Load Rating @240V Fluorescent 10A 10A Max Load Rating @240V Compact Fluorescent 10A 10A Max Load Rating @240V LED 10A 10A Blue Locator Ring Red Signal LED Neutral Required Timing Range 2min - 2h 2min - 2h 2min - 1h 2min - 1h Timing Cancellation Timing Re-Trigger Intelligent Power Search Facility N/A N/A Use with Contactor ** ** Section 4 / Page No. 4/4 4/4 4/4 4/4 4/4 NOTE: 3 Wire products have a neutral. 2 Wire products have no neutral. Slaves must be used with illuminated and connected with 3 Core cables to Master unit 2/4 Elkay Product Catalogue LIT-057GB 08/15

2 Touch Timer Touch Timer Touch Slave PIR Timer PIR Timer PIR Slave 560A-1 560A-3 560A-5 570A-1 570A-3 570A-5 3 Wire 2 Wire 3 Wire 2 Wire White White White White White White 8 mm 8 mm 8 mm 8 mm 8 mm 8 mm 65 mm 65 mm 65 mm 65 mm 65 mm 65 mm 2min - 2h 2min - 2h 2min - 2h 2min - 2h N/A N/A N/A N/A ** ** 4/5 4/5 4/5 4/5 4/5 4/5 **PFCC-1 Capacitor must be fitted at contactor - see Section 3/15 or contact Elkay Technical Elkay Product Catalogue LIT-057GB 08/15 2/5

Energy management Timers & Timers & Introduction 3/3 Columbus Timer - Single contacts 3/4 Columbus Timer - Double contacts 3/4 Columbus Electronic Timer 3/4 Pushbutton Timer - 2 Wire 3/5 Pushbutton Timer - 3 Wire 3/5 Pushbutton Timer Slave - 3 Core 3/5 Pushbutton Long Timer - 3 Wire 3/5 Standard Pushbutton Timer - 2 Wire 3/5 Standard Pushbutton Timer - 3 Wire 3/5 Touch Timer - 2 Wire 3/6 Touch Timer - 3 Wire 3/6 Touch Slave - 3 Core 3/6 PIR Timer - 2 Wire 3/6 PIR Timer - 3 Wire 3/6 PIR Slave - 3 Core 3/6 Standard PIR Timer - 3 Wire 3/6 Standard PIR Timer - 2 Wire 3/6 Ceiling Mount PIR - 3 Wire 3/7 Fireproof Ceiling Mount PIR - 3 Wire 3/7 Microwave Timer - 3 Wire 3/8 Remote Timer - 3 Wire 3/9 3 Accessories PFCC-1 Capacitor 3/9 Wall Surface Mount Box 3/9 Wall Spacer Plate 3/9 Elkay Product Catalogue LIT-057GB 08/15 3/1

3 3/2 Elkay Product Catalogue LIT-057GB 08/15

Timers & Introduction The Timers & Switches range from Elkay Electrical provides a simple and highly cost effective way of saving energy, which can be easily installed in existing buildings as it can be incorporated into new build schemes. 3 With a wide choice of timer controls for lighting and other types of electrical loads, products across the Energy Sense range provide a fast track route to substantial reduction both in energy bills and carbon emissions. From the Columbus pneumatic time delay switch to intelligent pushbutton, touch and PIR timers, the Energy Sense range offers extensive features, attractive styling and practical solutions. Elkay Product Catalogue LIT-057GB 08/15 3/3

Timers & Columbus timer & Columbus electronic timer Columbus Timer - Timers & Columbus Timer is an easy to fit and cost effective way of automatically turning lighting off after a set period of time. Pushing the button the contacts and activates the time delay, which can be set at installation anywhere between 5 seconds and 5 minutes (Note timings are approximate). 3 The unit has single or double contacts as standard and can be fitted to existing single gang, making it a perfect low cost energy saving solution in areas such as stairways, corridors and storerooms. Columbus Timer Timers & Key Features: For fluorescent (6 fittings max) and incandescent lighting Available in white finish No neutral required Replaces existing single gang wall switch 5 seconds to 5 minutes Pnuematic time delay switch - Technical specification Part No. Type Configuration Finish Rating 400A Columbus Timer SIngle contact arrangement White 3A-6A-240V 400A-3 Columbus Timer Double contact arrangement White 3A-6A-240V See Technical Section 5/2 for wiring diagram Columbus Electronic Timer - Timers & Columbus Electronic Timer is an easy to fit and cost effective way of automatically turning lighting off after a set period of time. Pushing the button the switch and activates the time delay, which can be set at installation anywhere between 20 seconds and 25 minutes. The unit can be fitted to existing single gang, making it a perfect low cost energy saving solution in areas such as stairways, corridors and storerooms. Columbus Electronic Timer Timers & Key Features: For fluorescent (2A) and incandescent (2A) lighting ONLY Available in white finish No neutral required Replaces existing single gang wall switch Capacitor required Easy loop in and out terminals for easy wiring Electronic time delay switch - Technical specification Part No. Type Finish Rating 400E Columbus Electronic Timer White 2A-240V *PFCC-1 Capacitor will often be required when switching certain types of load - see Section 3/15 for full details or contact Elkay Technical See Technical Section 5/2 for wiring diagram 3/4 Elkay Product Catalogue LIT-057GB 08/15

Timers & Pushbutton timer & Pushbutton long timer Pushbutton Timer - Timers & A stylish, electronic time delay switch for lighting and other power use, the pushbuttontimer can replace an existing switch to provide energy saving functionality by timing lighting and power sources off to avoid unnecessary power usage. This illuminated unit provides variable timing selection, with a backlit blue neon indicator ring available for aiding location in the dark. It also has the ability to latch back on to the mains power supply and reset in the event of a power cut. 3 Pushbutton Timer Timers & Key Features: For general purpose loads including resistive loads and incandescent / flourescent lighting Re-trigger function Concealed fixing screws on illuminated Last minute indicator on illuminated Time cancellation functions Standard Pushbutton Timer Timers & Electronic time delay switch - Technical specification Part No. Type Configuration Finish Rating 3875A-1*** Pushbutton Timer Master 3 Wire White -240V 350A-1*** Pushbutton Timer Master 2 Wire* for lighting only White -240V 350A-3 Pushbutton Slave 3 Core** White -240V 3875B-1 Standard Pushbutton Timer 3 Wire White 10A-240V 350B-1 Standard Pushbutton Timer 2 Wire* for lighting only White 10A-240V *PFCC-1 Capacitor will often be required when switching certain types of load - see Section 3/15 for full details or contact Elkay Technical **Slaves must be used with illuminated range and connected with 3 Core cables to Master unit. ***Slave unit required for multiway switching See Technical Section 5/4, 5/5 & 5/6 for wiring diagrams Pushbutton Long Timer - Timers & This version of our Push button timer can time from 8 minutes minimum to 8 hours maximum to provide longer time control. Ideal for long timing applications such as battery chargers, mobility scooters or areas with long occupation. Pushbutton Long Timer Timers & Key Features: For general purpose loads including resistive loads and incandescent / flourescent lighting Re-trigger function Concealed fixing screws on illuminated Last minute indicator on illuminated Time cancellation functions 8 minutes, 20,40,60,80,120,160,200,240, 280,320,360,400,440 and 480 minutes. Electronic time delay switch - Technical specification Part No. Type Configuration Finish Rating 3875A-1LT** Pushbutton Long Timer Master 3 Wire White -240V *PFCC-1 Capacitor will often be required when switching certain types of load - see Section 3/15 for full details or contact Elkay Technical **Slaves must be used with illuminated range and connected with 3 Core cables to Master unit. ***Slave unit required for multiway switching See Technical Section 5/4, 5/5 & 5/6 for wiring diagrams Elkay Product Catalogue LIT-057GB 08/15 3/5

Timers & Touch timer & PIR timer Touch Timer - Timers & The Touch Timer offers energy saving features at the lightest of touches. With the reliability of a fully electronic unit, with no mechanical moving parts, it has all the features of the Elkay push button timer unit with the additional benefit of tactile, feather light touch activation. 3 Variable timing selection, a backlit blue neon indicator ring and automatic reset are all part of this feature-packed device. It is also suitable for multi-way applications thanks to slave switch options with the 2 wire and 3 wire master devices. Touch Timer Timers & Key Features: Feather light touch activation For general purpose loads including resistive loads and incandescent / fluorescent lighting Re-trigger function Concealed fixing screws on illuminated Last minute indicator Electronic time delay switch - Technical specification Part No. Type Configuration Finish Rating 2235A-1*** Touch Timer Master 3 Wire White -240V 360A-1*** Touch Timer Master 2 Wire* (for lighting only) White -240V 360A-3 Touch Slave 3 Core** White -240V *PFCC-1 Capacitor will often be required when switching certain types of load - see Section 3/15 for full details or contact Elkay Technical **Slaves must be used with illuminated range and connected with 3 Core cables to Master unit. ***Slave unit required for multiway switching See Technical Section 5/4, 5/6 for wiring diagrams PIR Timer - Timers & The PIR Timer is a fully automatic device which controls various power loads through the detection of body heat. Activated by the detection of moving body heat, the lighting or power load will then stay on for a preset period of time. If body heat is no longer detected, the time period will elapse and the load will be switched off. An internal light sensor will keep the lighting switched off when suffi cient ambient light is available, further increasing the energy saving potential of the PIR Timer. The unit also has an override switch on the faceplate (illuminated only). By removing user interaction, the PIR Timer has ultimate reliability, resulting in a fi t and forget way of introducing active energy management. PIR Timer Timers & Key Features: Passive Infra Red movement sensor For general purpose loads including resistive loads and incandescent / fluorescent lighting Re-trigger function Concealed fixing screws on illuminated Last minute indicator on illuminated Standard PIR Timer Timers & Passive infra red (PIR) timer switch - Technical specification Part No. Type Configuration Finish Rating 370A-1*** PIR Timer Master 3 Wire White -240V 376A-1*** PIR Timer Master 2 Wire* (for lighting only) White -240V 376A-3 PIR Slave 3 Core** White -240V 370B-1 Standard PIR Timer 3 Wire White 10A-240V 376B-1 Standard PIR Timer 2 Wire* (for lighting only) White 10A-240V *PFCC-1 Capacitor will often be required when switching certain types of load - see Section 3/15 for full details or contact Elkay Technical **Slaves must be used with illuminated range and connected with 3 Core cables to Master unit. ***Slave unit required for multiway switching See Technical Section 5/4, 5/5 & 5/6 for wiring diagrams 3/6 Elkay Product Catalogue LIT-057GB 08/15

Timers & Ceilingmount PIR & Fireproof ceilingmount PIR Ceilingmount PIR - Timers & (New improved design) This PIR timer unit has been specifically designed for ceiling mounting and includes spring fixing arms for quick and easy installation. This compact unit is one of the smallest most discrete units available and can be fl ush mounted or surface mounted with a surface mounting box. It can also be mounted on BESA boxes. The PIR is activated by the detection of moving infra red and has the added feature of a red indicator LED to signify when timing has been retriggered and when the unit is in its fi nal minute of countdown. The time control is from 2 minutes to 1 hour and it features a white and chrome bezel alowing easy access to timing, lux and sensitivity control without the need for removing from the ceiling. 3 Ceilingmount PIR Timers & Key Features: For general purpose use and 10A for all load types Sensitivity Adjustment control Auto Lux and Manual Lux for extra daylight saving control 10 second test mode to speed up installation time Easy fit secure arm fixing for flush mounting Compact 64mm Diameter Surface mount option built in Ceiling mounted (PIR) timer - Technical specification Part No. Type Configuration Finish Rating 374B-1 Ceilingmount PIR 3 Wire White 10A-240V *PFCC-1 Capacitor will often be required when switching certain types of load - see Section 3/15 for full details or contact Elkay Technical See Technical Section 5/3 for wiring diagram and detection zones Fireproof Ceilingmount PIR - Timers & This PIR timer unit has been specifi cally designed to meet the growing need from building control to maintain fi reproof qualities in ceilings in public buildings and new builds extensions. Its intelligent pre wired design is particularly useful for ceilings where access above is limited or difficult. This compact unit is one pre wired for your convenience and has intumescent seals designed to comply with domestic and commercial fire requirements from building control. Fireproof Ceilingmount PIR Timers & The PIR is activated by the detection of moving infra red and has the added feature of a red indicator LED to signify when timing has been retriggered and when the unit is in its final minute of countdown. The time control is from 2 minutes to 1 hour and it features a white and chrome bezel alowing easy access to timing, lux and sensitivity control without the need for removing from the ceiling. Key Features: For general purpose use and 10A for all load types Sensitivity Adjustment control Auto Lux and Manual Lux for extra daylight saving control 10 second test mode to speed up installation time Easy fit secure arm fixing for flush mounting Compact 84mm Diameter Pre wired in 3 core cable for your convenience Fireproof ceiling mounted (PIR) timer - Technical specification Part No. Type Configuration Finish Rating 374B-1FPC Fireproof Ceilingmount PIR 3 Wire White 10A-240V *PFCC-1 Capacitor will often be required when switching certain types of load - see Section 3/15 for full details or contact Elkay Technical See Technical Section 5/3 for wiring diagram and detection zones Elkay Product Catalogue LIT-057GB 08/15 3/7

Timers & Microwave timer Microwave Timer - Timers & This Microwave Sensor is a high performance presence detector with a built in Lux level and sensitivity adjustment that is ideal for corridors, and other larger areas. The Microwave Sensor sends out a high frequency sound wave over a range of up to 30 metres. 3 Microwave Timer Timers & Key Features: 16amp switching regardless of load type Timing from 2minutes to 2 hours Lux level/daylight adjustment Clip on front cover to conceal screws Adjustment on the sensitivity Option to retrofit into existing systems Cost effective switch with reduced cabling and labour costs to installers - see diagram below 15-30 metre detection zone Microwave sensor - Technical specification Part No. Type Configuration Finish Rating 380A-1 Microwave Timer 3 Wire White -240V *PFCC-1 Capacitor will often be required when switching certain types of load - see Section 3/15 for full details or contact Elkay Technical See Technical Section 5/7 for wiring diagram When using PIRs in long corridors or spaces, there is often a need to position them every 6 to 8 metres. This incurs additional cabling, labour and connection costs at install. Maintenance costs over time are also increased from a PPM perspective as there are more devices to check and maintain. With the Elkay Microwave detector 380A-1 mounted on the wall only one device is needed to cover areas up to 30 metres with lateral cover provided for up to 8 metres which increases overall flexibility. Microwave Detectors reduce cabling,connection, labour and future PPM costs simply because fewer detectors are needed. They can be mounted from 2 to 5m in height and should be wall mounted for best effect. They can also be used in hi bay lamps that are PL types or hot re strike luminaires. 3/8 Elkay Product Catalogue LIT-057GB 08/15

Timers & Remote timer & Accessories Remote Timer - Timers & The Remote Timer is suitable for use in inaccessible areas, such as stairwells and corridors, using slave activators or momentary to operate the timer. The unit has a blank faceplate and is therefore tamper proof. The Remote Timer is designed for general purpose loads, which enables it to be used on a variety of applications from lighting through to heating and ventilation. On installation the timing delay can be set for periods of between 2 minutes and 2 hours. 3 Remote Timer Timers & Key Features: For general purpose loads including resistive loads and incandescent / fluorescent lighting Adjustable from 2 minutes to 2 hours Clip on front plate 8mm deep 16 Amp max load regardless of load type Works in conjunction with all Elkay slave and momentary Remote activated timer switch - Technical specification Part No. Type Configuration Finish Rating 320A-1 Remote Timer 3 Wire White -240V See Technical Section 5/3 for wiring diagram Pushbutton Accessories Wall Mount Box Accessories Wall Spacer Plate Accessories PFCC-1 Capacitor The PFCC-1 Capacitor is designed to assist in switching low wattage and low voltage loads. The Capacitor MUST be fitted with the following types of load: Low voltage Low wattage LED loads Contactors Wall Spacer Plate Designed to fit between a switch or timer and the wall where standard 16mm cavity boxes have already been installed, saving installation time and not having to replace cavity back box with a 25mm deep box. Power factor correction capacitor - Technical specification Part No. Type PFCC-1 Power Factor Correction Capacitor In addition all 2 wire without a neutral will need a capacitor in circuit ITEM IS SOLD SEPARATELY Wall mount box & wall spacer plate - Technical specification Part No. Type Finish 210A-1 Wall Mount Box White 220A-1 Wall Spacer Plate White metres approx. metres Maintained Maintained approx. 7 metres approx. metres Maintained approx. Live Maintained Maintained Live Live Live Switched Switched Switched Live Switched Switched Live Live Live Neutral Neutral Neutral Neutral Please PLEASE Note: NOTE: The The maintained live liveis Please not is not always always Note: present The present maintained on on all fittings. all fittings live is not Please Please always Note: Note: present The maintained The maintained on all fittings. live is live is not always present on all fittings. not always present on all fittings. PFCC-1 PFCC-1 PFCC-1 PFCC-1 4uf 250V PFCC-1 4uf ac 250V 4uf 4uf ac 250V ac 250V ac Elkay Product Catalogue LIT-057GB 08/15 3/9

Energy management Outdoor timers & Outdoor timers & Introduction 4/3 Pushbutton Timer Master - 3 Wire 4/4 Pushbutton Slave - 3 Core 4/4 Standard Pushbutton Timer - 3 Wire 4/4 Standard Pushbutton Timer - 2 Wire 4/4 Touch Timer Master - 3 Wire 4/5 Touch Slave - 3 Core 4/5 PIR Timer Master - 3 Wire 4/5 PIR Slave - 3 Core 4/5 4 Elkay Product Catalogue LIT-057GB 08/15 4/1

4 4/2 Elkay Product Catalogue LIT-057GB 08/15

Outdoor timers & Introduction With Elkay, energy saving can now be extended to suit your outdoor requirements. With the brand new range of Outdoor Timers & Switches, ambient and security lighting and power applications can be timer controlled in outdoor environments including parking areas and gardens. 4 Designed to give IP66 waterproof rating, the easy to fit products are supplied complete with an enclosure, mounting screws and screw cover seals and are suitable for use with M20 cable glands or Adaptalok flexible conduit system. Offering a choice of pushbutton, touch, PIR and outdoor timers giving functionality, style and durability to outdoor energy saving. Elkay Product Catalogue LIT-057GB 08/15 4/3

Outdoor timers & Pushbutton timer & Standard pushbutton timer Pushbutton Timer - Outdoor timer & The Outdoor Pushbutton Timer provides an electronic time delay switch for lighting and other power uses in outdoor environments. Ideal for use in driveways, gardens and patio areas. This easy to fit and highly cost effective unit offers energy saving functionality by timing lighting and power sources off to avoid unnecessary power usage. 4 Pushbutton Timer Outdoor timers & Featuring a backlit blue neon indicator ring to aid location in the dark, these intelligent units have the ability to latch back on to the mains power supply and reset in the event of a power cut. The unit is supplied with a surface mounted back box with knockouts on five faces, mounting screws and screw cover seals. Key Features: For general purpose loads including resistive loads and incandescent / flourescent lighting Re-trigger function Time cancellation functions Outdoor electronic time delay switch - Technical specification Part No. Type Configuration Finish Rating 550A-1*** Pushbutton Timer Master 3 Wire White -240V 550A-3*** Pushbutton Timer Master 2 Wire* (for lighting only) White -240V 550A-5 Pushbutton Slave 3 Core** White -240V *PFCC-1 Capacitor will often be required when switching certain types of load - see Section 3/15 for full details or contact Elkay Technical **Slaves must be used with illuminated range and connected with 3 Core cables to Master unit. ***Slave unit required for multiway switching See Technical Section 5/4 & 5/6 for wiring diagrams Standard Pushbutton Timer - Outdoor timers & The Outdoor Pushbutton Timer provides an electronic time delay switch for lighting and other power uses in outdoor environments. Ideal for use in driveways, gardens and patio areas. This easy to fit and highly cost effective unit offers energy saving functionality by timing lighting and power sources off to avoid unnecessary power usage. Standard Pushbutton Timer Outdoor timers & Key Features: For general purpose loads including resistive loads and incandescent / flourescent lighting Re-trigger function Time cancellation functions Outdoor electronic time delay switch - Technical specification Part No. Type Configuration Finish Rating 550B-1 Standard Pushbutton Timer 3 Wire White 10A-240V 550B-3 Standard Pushbutton Timer 2 Wire* (for lighting only) White 10A-240V *PFCC-1 Capacitor will often be required when switching certain types of load - see Section 3/15 for full details or contact Elkay Technical See Technical Section 5/5 for wiring diagrams **Slaves must be used with illuminated range and connected with 3 Core cables to Master unit. ***Slave unit required for multiway switching See Technical Section 5/4, 5/5 & 5/6 for wiring diagrams 4/4 Elkay Product Catalogue LIT-057GB 08/15

Outdoor timers & Touch timer & PIR timer Touch Timer - Outdoor timers & The Energy Outdoor Touch Timer offers superb functionality and energy saving features with a subtle touch activation for a wide range of outdoor use. The Touch Timer, when used in outdoor environments offers increased reliability as a non-mechanical electronic unit. Knockouts on five faces, mounting screws and seal screw covers make for ease of installation. Touch Timer Outdoor timers & Variable timing selection, a backlit blue neon indicator ring and automatic reset are all part of this feature-packed device. It is also suitable for multi-way applications in slave switch options with the 2 wire and 3 wire Master devices. Key Features: For general purpose loads including resistive loads and incandescent / flourescent lighting Re-trigger function Time cancellation function Last minute indicator 16 Amp max load regardless of load type 4 Outdoor electronic time delay switch - Technical specification Part No. Type Configuration Finish Rating 560A-1*** Touch Timer Master 3 Wire White -240V 560A-3*** Touch Timer Master 2 Wire* (for lighting only) White -240V 560A-5 Touch Slave 3 Core** White -240V *PFCC-1 Capacitor will often be required when switching certain types of load - see Section 3/15 for full details or contact Elkay Technical **Slaves must be used with illuminated range and connected with 3 Core cables to Master unit. ***Slave unit required for multiway switching See Technical Section 5/4 & 5/6 for wiring diagrams PIR Timer - Outdoor timers & The PIR Timer acts on detection of moving body heat, activating the outdoor lighting or power load, which stays on during the selected time period. An internal light sensor can be adjusted to keep lighting switched of when sufficient ambient light is available. The unit has an override switch on the faceplate. This IP66 rated intelligent unit, provides variable timing selection and incorporates an override facility. These intelligent units have the ability to latch back on to the mains power supply and reset in the event of a power cut. PIR Timer Outdoor timers & Key Features: For general purpose loads including resistive loads and incandescent / flourescent lighting Re-trigger function Last minute indicator 16 Amp max load regardless of load type Passive infra red (PIR) timer switch - Technical specification Part No. Type Configuration Finish Rating 570A-1*** PIR Timer Master 3 Wire White -240V 570A-3*** PIR Timer Master 2 Wire* (for lighting only) White -240V 570A-5 PIR Slave 3 Core White -240V *PFCC-1 Capacitor will often be required when switching certain types of load - see Section 3/15 for full details or contact Elkay Technical Elkay Product Catalogue LIT-057GB 08/15 4/5

Energy management Technical section. Wiring & Connection Diagrams Wiring diagrams Columbus Timer 5/2 Columbus Electronic Timer 5/2 Ceilingmount PIR 5/3 Remote Timer 5/3 Illuminated PIR Timer - 2 Wire 5/4 Illuminated PIR Timer - 3 Wire 5/4 Illuminated Pushbutton / Touch Timer - 2 Wire 5/4 Illuminated Pushbutton / Touch Timer - 3 Wire 5/4 Standard Pushbutton / PIR Timer - 2 Wire (for lighting only) 5/5 Standard Pushbutton / PIR Timer - 3 Wire (for all load types) 5/5 Two Wire Master with Pushbutton, Touch or PIR Slave - 2 Wire 5/6 Three Wire Master with Pushbutton, Touch or PIR Slave - 3 Wire 5/6 Multiple Slave Fitting - Illuminated Timers 5/6 Microwave Timer 5/7 5 Timing diagrams Microwave Timer 5/8 Ceilingmount PIR and Fireproof Ceilingmount PIR 374B-1, 374B-1FPC 5/8 Dip for 3 Wire Units (except 374B-1 & 374B-1FPC) 5/9 Dip for all 2 Wire Units 5/9 Personalised wiring diagrams can be provided by Elkay Technical by calling 01675 468200 or by sending an email to techinfoelk@tnb.com Elkay Product Catalogue LIT-057GB 08/15 5/1

Technical section Wiring diagrams Columbus Timer Columbus Timer fitting 400A Single contact push button timer 400A-3 Double contact push button timer Rating at 240V a.c. Incandescent 6A Compact Fluorescent 3A Resistive 6A (max 6 Fittings) Time Delay 5sec - 5min Fluorescent 3A (max 6 Fittings) Typical Circuit for Corridor Lighting (i.e. Lights will stay on until last timer goes off) Typical Circuit for Staircase Lighting where the Live and Switch Live are at different positions 5 Lux level adjustment Columbus Electronic Timer Columbus Electronic Timer fitting 400E Rating at 240V a.c. 2A All load types Typical Circuit for Corridor Lighting (i.e. Lights will stay on until last timer goes off) Switched Live Switched Live Switched Live NOTE: Capacitor will be required when switching compact fluorescent or very low power lighting. For example: 2D fittings, energy saving lamps, LEDs or any low power consuming loads and must be used across contactors. IMPORTANT NOTICE: All wiring should be carried out by a competent person or a qualified Electrician in accordance with the current IET Wiring Regulations. If you believe the unit is faulty call Elkay technical on 01675 468200 or return to place of purchase. 5/2 Elkay Product Catalogue LIT-057GB 08/15

Technical section Wiring diagrams Ceilingmount PIR Ceilingmount PIR Fitting - Three Wire* 374B-1, 374B-1FPC Rating at 240V a.c. 10A 7 metres approx. Ceilingmount PIR sensor detection diagram 4 metres 7 metres approx. CEILING FLOOR 5 7 7 metres approx.. 4 metres 7 Remote Timer Remote Timer Fitting / Slave Fitting - Three Wire 320A-1 Rating at 240V a.c. All load types Time Delay 2min - 2h Slave options (350A-3, 360A-3, 376A-3) Momentary can also be used with Remote Timer REMOTE TIMER 320A-1 *See Section 5/8 for 3 Wire dip SLAVE OR MOMENTARY NOTE: Can also be used with momentary. Contact Elkay technical for details 01675 46822 IMPORTANT NOTICE: All wiring should be carried out by a competent person or a qualified Electrician in accordance with the current IET Wiring Regulations. If you believe the unit is faulty call Elkay technical on 01675 468200 or return to place of purchase. Elkay Product Catalogue LIT-057GB 08/15 5/3

Technical section Wiring diagrams Illuminated PIR Timer - 2 Wire Illuminated Pushbutton / Touch Timer - 2 Wire 5 PIR Timer fitting - 2 Wire* 376A-1, 570A-3 Rating at 240V a.c. Time Delay 2min - 2h IN Plan VIew Side VIew 4-6m 4-6m 4-6m Pushbutton / Touch Timer fitting (illuminated) - 2 Wire* 350A-1, 360A-1, 550A-3, 560A-3 Rating at 240V a.c. Time Delay 2min - 2h 4-6m 4-6m 3-4m 3-4m 4-6m 3-4m 3-4m 3-4m Lux level adjustment 3-4m Power Factor Correction Capacitor (PFCC-1) When using 2 wire units with compact fluorescent or very low power lighting a power factor correction capacitor of 4 microfarads will often be required. Illuminated PIR Timer - 3 Wire PIR Timer fitting - 3 Wire** 370A-1, 570A-1 Rating at 240V a.c. Time Delay 2min - 2h IN Plan VIew Side VIew 3-4m 4-6m 3-4m 3-4m 4-6m 4-6m Illuminated Pushbutton / Touch Timer - 3 Wire Pushbutton / Touch Timer fitting (illuminated) - 3 Wire** 3875A-1, 2235A-1, 550A-1, 560A-1 Rating at 240V a.c. Time Delay 2min - 2h 7 metres approx. 7 metres approx. 7 metres approx. LIVE OUT 4 metres 4 metres FLOOR NOTE: Capacitor 7 metres approx. will be 4 metres 4-6m 4-6m 3-4m CEILING 3-4m CEILING required when switching FLOOR compact 7 metres fluorescent approx. or very low power lighting. For example: 2D fittings, energy saving lamps, LEDs or any low power consuming loads and must be 7 metres approx. used across contactors. CEILING FLOOR *See Section 5/9 for 2 Wire dip **See Section 5/9 for 3 Wire dip IMPORTANT NOTICE: All wiring should be carried out by a competent person or a qualified Electrician in accordance with the current IET Wiring Regulations. If you believe the unit is faulty call Elkay technical on 01675 468200 or return to place of purchase. 5/4 Elkay Product Catalogue LIT-057GB 08/15

Technical section LIVE IN Wiring diagrams LIVE IN LIVE OUT Standard Pushbutton / PIR Timer - 2 Wire (for lighting only) 55 - - 7m 7m Standard Pushbutton / Standard PIR Timer SL L fitting - 2 Wire SL SLL L (for lighting only)* 350B-1, 376B-1, 550B-3 SL L SL SLL L Rating at 240V a.c. N SL L 10A N Time Delay 2min - 1h NSLSLL L Plan VIew SL LSL L LIVE IN LIVE OUT LIVE IN LIVE OUT Multiple Switching 4-6m 4-6m 55 - - 7m 7m 55 - - 7m 7m SL SL L L SL SL L L SL L N N SL SL L L Side VIew N SL L 5 SL L Single Switching 3-4m 3-4m 55 - - 7m 7m NOTE: 2 Wire devices not to be used with contactors. Capacitor will often be required when switching compact fluorescent or very low power lighting. For example: 2D fittings, energy saving lamps, LEDs or any low power consuming loads. Standard Pushbutton / PIR Timer - 3 Wire (for all load types) Standard Pushbutton / Standard PIR Timer fitting - 3 Wire** 3875B-1, 370B-1, 550B-1 Rating at 240V a.c. 10A Time Delay 2min - 1h Plan VIew IN IN Multiple Switching LIVE OUT 4-6m 4-6m 55 - - 7m N SL L N NSLSLL L N SL L N NSLSLL L N SL L N NSLSLL L Side VIew N SLN LSL L LIVE IN LIVE LIVE OUT OUT Single Switching LIVE IN LIVE LIVE OUT OUT NOTE: Capacitor will be required when switching compact fluorescent or very low power lighting. For example: 2D fittings, energy saving lamps, LEDs or any low power consuming loads and must be used across contactors. 3-4m 3-4m 55 - - 7m 7m 55 - - 7m 7m N SL L N SL L N SL L N SL L N SL L *See Section 5/9 for 2 Wire dip **See Section 5/9 for 3 Wire dip N SL L N SL L N SL L N SL L IMPORTANT NOTICE: All wiring should be carried out by a competent person or a qualified Electrician in accordance with the current IET Wiring Regulations. If you believe the unit is faulty call Elkay technical on 01675 468200 or return to place of purchase. N SL SLL N SL L Elkay Product Catalogue LIT-057GB 08/15 5/5 55 - - 7m 7m

Technical section Wiring diagrams Two Wire Master with Pushbutton, Touch or PIR Slave 5 Pushbutton Slave / Touch Slave / PIR Slave fitting (illuminated) 3 Core connection to Master SLAVE PART NUMBERS: 350A-3, 360A-3, 376A-3, 550A-5, 560A-5, 570A-5 Rating at 240V a.c. Masters & Slaves - 2 Wire Masters Slaves 350A-1 350A-3 360A-1 360A-3 376A-1 376A-3 550A-3 550A-5 560A-3 560A-5 570A-3 570A-5 Lux level adjustment Lux level adjustment Lux level adjustment Lux level adjustment Lux level adjustment Lux level adjustment *Optional wire for blue indicator ring on pushbutton slaves only. 2 WIRE MASTER SLAVE *Optional wire for blue indicator *Optional wire for blue indicator only. *Optional ring pushbutton ring wire for blue slaves pushbutton indicator only. *Optional wire for blue slaves indicator only. ring on pushbutton slaves only. ring on pushbutton slaves only. *Optional wire for blue indicator ring on pushbutton slaves only. Three Wire Master with Pushbutton, Touch or PIR Slave Lux level Pushbutton Slave / Touch Slave / PIR Slave fitting (illuminated) - 3 Core SLAVE PART NUMBERS: 350A-3, 360A-3, 376-A, 550A-5, 560A-5, 570A-5 Rating at 240V a.c. Masters & Slaves - 3 Wire Masters Slaves 3875A-1 350A-3 2235A-1 360A-3 370A-1 376A-3 550A-1 550A-5 560A-1 560A-5 570A-1 570A-5 320A-1 Any Slave above 520A-1 Any Slave above Multiple Slave Fitting - Illuminated Timers adjustment 3 WIRE MASTER Lux level adjustment Lux level adjustment LIVE Lux OUT level adjustment Lux level adjustment *Optional wire for blue indicator ring on pushbutton slaves only. *Optional wire for blue indicator ring *Optional pushbutton wire for blue slaves indicator only. *Optional wire for blue indicator ring *Optional pushbutton wire for blue slaves indicator only. ring on pushbutton slaves only. ring on pushbutton slaves only. *Optional wire for blue indicator *Optional ring pushbutton wire for blue slaves indicator only. *Optional wire for blue indicator LIVE IN ring *Optional pushbutton wire for blue slaves indicator only. ring on pushbutton slaves only. ring on pushbutton slaves only. *Optional wire for blue indicator ring on pushbutton slaves only. ring on pushbutton slaves only. SLAVE *Optional wire for blue indicator *Optional wire for blue ring pushbutton indicator *Optional wire for blue slaves indicator only. ring on pushbutton slaves only. ring on pushbutton slaves only. Lux level adjustment MASTER SLAVE SLAVE *Optional wire for blue indicator ring on pushbutton slaves only. IMPORTANT NOTICE: All wiring should be carried out by a competent person or a qualified Electrician in accordance with the current IET Wiring Regulations. If you believe the unit is faulty call Elkay technical on 01675 468200 or return to place of purchase. 5/6 Elkay Product Catalogue LIT-057GB 08/15

Technical section Wiring diagrams Microwave Timer Microwave Timer fitting - 3 Wire* 380A-1 Rating at 240V a.c. Time Delay 2min - 2hrs Wiring diagram for a 3 Wire Microwave unit Wiring diagram for additional Microwave units TOP LUX SEN TOP LUX SEN TOP LUX SEN 5 TOP N SL L TOP N SL L TOP N SL L N SL L LUX SEN LUX SEN LUX SEN N SL L N SL L N SL L Power Factor Correction Capacitor (PFCC-1) When using 2 wire units with compact fluorescent or very low power lighting a power factor correction capacitor of 4 microfarads will often be required. N SL L Plan view of Micowave pattern 30m AREA OF HIGH SENSITIVITY 6m 30m AREA OF LOW SENSITIVITY AREA OF HIGH SENSITIVITY 6m AREA OF LOW SENSITIVITY *See Section 5/8 for 3 Wire dip IMPORTANT NOTICE: All wiring should be carried out by a competent person or a qualified Electrician in accordance with the current IET Wiring Regulations. If you believe the unit is faulty call Elkay technical on 01675 468200 or return to place of purchase. Elkay Product Catalogue LIT-057GB 08/15 5/7

N SL L Technical section Timing diagrams 30m 30m Dip for Microwave Timer - 380A-1 Please note that the black bar denotes the position of the dip switch: 6m 6m AREA OF HIGH SENSITIVITY AREA OF HIGH SENSITIVITY AREA OF LOW SENSITIVITY AREA OF LOW SENSITIVITY 5 ON DIP ON DIP 2 mins 5 mins 10 mins 15 mins 20 mins 25 mins 30 mins 40 mins ON DIP ON DIP ON DIP ON DIP ON DIP ON DIP ON DIP ON DIP ON DIP ON DIP ON DIP ON DIP ON DIP ON DIP 50 mins 60 mins 70 mins 80 mins 90 mins 100 mins 110 mins 120 mins Dip for Ceilingmount PIR & Fireproof Ceilingmount PIR - 374B-1, 374B-1FPC Please note that the black bar denotes the position of the dip switch: Auto Lux Manual Lux Dip switch 4 is only used for Setting Automatic (150 Lux) or Manual Lux ONLY. Test Mode 10 Secs 2 mins 5 mins 10 mins 15 mins 20 mins 30 mins 60 mins TEST SETTINGS (Test Mode to 60 mins) IMPORTANT NOTICE: All wiring should be carried out by a competent person or a qualified Electrician in accordance with the current IET Wiring Regulations. If you believe the unit is faulty call Elkay technical on 01675 468200 or return to place of purchase. 5/8 Elkay Product Catalogue LIT-057GB 08/15

Technical section Timing diagrams 30m 30m AREA OF HIGH AREA SENSITIVITY OF HIGH SENSITIVITY Dip for TOP3 Wire Illuminated Switches TOP & Wall sensors (except 374B-1, TOP 374B-1FPC) LUX SEN LUX SEN LUX SENSITIVITY Please note that the black bar denotes the position of the dip switch: 6m 6m AREA OF LOW AREA SENSITIVITY OF LOW ILLUMINATED N SL L 3 WIRE 3875A-1 2235A-1 370A-1 550A-1 560A-1 570A-1 STANDARD 3 WIRE 3875B-1 370B-1 550B-1 ON DIP ON DIP N SL L ON DIP ON DIP ON DIP ON DIP ON DIP ON DIP N 2 mins 5 mins 10 mins 15 mins 20 mins 25 mins 30 mins 40 mins 50 mins 60 mins 70 mins 80 mins 90 mins 100 mins 110 mins 120 mins 30m 2 mins 5 mins 10 mins 15 mins 20 mins 30 mins 40 mins 60 mins 6m SL L ON DIP ON DIP ON DIP ON DIP ON DIP ON DIP ON DIP ON DIP N SL L AREA OF HIGH SENSITIVITY 5 AREA OF LOW SENSITIVITY Dip for 2 Wire Switches & Wall Sensors Please note that the black bar denotes the position of the dip switch: ILLUMINATED MASTER TIMER 350A-1 360A-1 376A-1 550A-3 560A-3 570A-3 2 mins 5 mins 10 mins 20 mins 40 mins 60 mins 90 mins 120 mins STANDARD TIMER 350B-1 376B-1 550B-3 2 mins 5 mins 10 mins 20 mins 40 mins 60 mins IMPORTANT NOTICE: All wiring should be carried out by a competent person or a qualified Electrician in accordance with the current IET Wiring Regulations. If you believe the unit is faulty call Elkay technical on 01675 468200 or return to place of purchase. Elkay Product Catalogue LIT-057GB 08/15 5/9

For your notes 5 5/10 Elkay Product Catalogue LIT-057GB 08/15

Contact us Elkay UK Head Office Station Road Coleshill Birmingham B46 1 HT Tel: +44 (0) 1675 468 222 Fax: +44 (0) 1675 464 930 www.elkay.co.uk Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2015 ABB All rights reserved Copyright ABB. LIT-057GB 08/15