SNK BA (6ES7132-6BF60-0AA0)

Similar documents
SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) SIMATIC. S7-1500/ET 200MP DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) Preface

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Programming and Operating Manual

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

Validity 1. Installation 2 SIMATIC. WinCC flexible Tag simulator Update 1. Readme

Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3. Simatic. Readme. Readme

Creating the project and hardware. TIA Portal. SIMATIC Creating the project and hardware. Introduction to the TIA Portal 1. Creating a project

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

WinCC Runtime Professional Readme SIMATIC HMI. WinCC V11 SP1. Readme WinCC Runtime Professional. Special considerations for Windows 7.

Configuration limits for products of the SIMATIC NET PC Software V12 SIMATIC NET. Configuration limits for products of the SIMATIC NET PC Software V12

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

S SIMATIC S Welcome. Automation task. Hardware section 2. Software section 3. Security. Getting Started 05/2014 A5E AC

SIMATIC. ET 200S distributed I/O 2AI U ST analog electronic module (6ES7134-4FB01-0AB0) Preface. Properties 1. Parameters 2.

Short-circuit current rating (SCCR) of. industrial control panels. NEC Article 409 and UL 508A

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection (V12.1) Preface 1. Virus scanner administration 2.

COMOS. Lifecycle COMOS Snapshots. "COMOS Snapshots" at a glance 1. System requirements for installing "COMOS Snapshots" Database management 3

S7-400H SIMATIC. Fault-tolerant systems S7-400H. Preface 1 Fault-tolerant automation systems. S7-400H setup options 3.

Modular I/O System Analog and Digital Interface Modules

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

Web server SIMATIC. S Web server. Preface. Documentation guide. General information. Websites 3. Function Manual 12/2014 A5E AD

Performing an automated installation

Patch management and security. updates SIMATIC. Process Control System PCS 7 Patch management and security updates. Preface 1

SIMATIC. S7 300 PLC CPU 317T-2 DP: Controlling a virtual axis. Introduction. Preparation. Learning units 3. Further information 4.

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives. Load-balanced control application

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

LOGO! LOGO! App V.10. LOGO! app 1. Making basic settings and establishing a connection to LOGO! Using the device overview 3. Creating controls 4

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

SIMATIC NET. Functions (FC) and function blocks (FB) for SIMATIC NET S7 CPs. Preface. Overview and general information on working with FCs and FBs

CP Page 1342 Mar 2008 Siemens ITS

SIMATIC. ET 200S distributed I/O IM151-1 STANDARD interface module (6ES7151-1AA05-0AB0) Preface. Properties 1. Parameters 2.

The CP provides access to different communication services of the PROFIBUS bus system:

Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1

Permissible ambient temperature Operation Storage, transport

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

6ES BE01-0AB0 6ES BE01-0AB0

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

CP SIMATIC NET. S Telecontrol CP Preface. Application and properties. Displays and connectors 2

The CP FO provides access to different communication services of the PROFIBUS bus system:

SIMATIC HMI. WinCC flexible 2008 Getting Started - First-Time Users Getting Started. Printout of the Online Help 06/2008 A5E

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Part 1: User information SIMATIC ET 200B Distributed I/O Station Manual Part 2: Reference information Appendices EWA 4NEB c Edition 04

2 Counter Module SIMATIC. S7-300 FM Counter module. Preface. Product Overview. How the FM Counts 2. Installing and Removing the FM 350-

Information Server Documentation SIMATIC. Information Server V8.0 Update 1 Information Server Documentation. Introduction 1. Web application basics 2

SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

SITOP UPS1600 / UPS1100. SITOP power supply SITOP UPS1600 / UPS1100. Overview. Safety information. Description, device design, dimension drawing 2

1 Application Description Objective Goals... 3

CPUs - CPU PN/DP

Fieldbus slave modules with I/Os, DIO

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

PROFINET CPU 314C-2 PN/DP, PN/DP, PN/DP, PN/DP: Configuring the PROFINET interface

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents

How To Write A Profibus Dpl (Profibus) Program

Realize your full potential with the new version of SIMATIC PCS 7

SIMATIC. SIMATIC Logon. User management and electronic signatures. Hardware and Software Requirements. Scope of delivery 3.

SIMATIC HMI. WinCC V7.3. WinCC/DataMonitor. WinCC/DataMonitor. Installation Notes 1. WinCC/DataMonitor Release Notes 2

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

Non-Isolated Analog Voltage/Current Output module IC695ALG704 provides four configurable voltage or current output channels. Isolated +24 VDC Power

mecotron Safety relay ESTOP-2 For emergency stop monitoring

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Allen-Bradley/Rockwell

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

Service & Support. Higher-level safe switch-off of the power supply of functionally nonsafe standard modules? Wiring Examples.

Security basics and application SIMATIC NET. Industrial Ethernet Security Security basics and application. Preface. Introduction and basics

Safety Relays ESM/ESM-F

L5354 ControlNet Communications Interface

User Manual Revision English

PROFINET IO Diagnostics 1

User Manual Revision English

Digital input modules

Addendum to the Operating Instructions

PCS0100en Persy Control Services B.V. Netherlands

SIMATIC. Open TCP/IP Communication via Industrial Ethernet. Contents Open TCP/IP Communication via Industrial Ethernet 1. Index.

s Preface SIMATIC Configuring Hardware and Communication Connections with STEP 7 Contents Basics of Configuring Hardware with STEP 7 1

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

SIMATIC NET. DP Base Programming Interface for CP 5613/CP Preface, Contents. Basic Steps in Creating a DP Application 1

BK MIKRO9. Tool monitoring system. Getting Started with Profibus Release 1.00 /

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB Drives. User s Manual HTL Encoder Interface FEN-31

IEEE P802.3af DTE Power via MDI Task Force Presentation Phil Holland

DB Administration COMOS. Platform DB Administration. Trademarks 1. Prerequisites. MS SQL Server 2005/ Oracle. Operating Manual 09/2011

CPU PN/DP. Function

Software redundancy for SIMATIC S7 SIMATIC. S7-300/S7-400 Software redundancy for SIMATIC S7. Contents 1

S7 CPs for Industrial Ethernet - SIMATIC NET. S Industrial Ethernet S7 CPs for Industrial Ethernet - CP Advanced.

Cross-beam scanning system to detect slim objects. 100 mm in

Overview of service and diagnostics. options SIMOTION. SIMOTION SCOUT Overview of service and diagnostics options. Preface 1.

5SV Residual Current Protective Devices

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Transcription:

SIMATIC ET 200SP Digital output module DQ 8x24VDC/0,5A SNK BA (6ES7132-6BF60-0AA0) Manual Edition 02/2014 Answers for industry.

DQ 8x24VDC/0,5A SNK BA Digital Output Module (6ES7132-6BF60-0AA0) SIMATIC ET 200SP DQ 8x24VDC/0,5A SNK BA digital output module (6ES7132-6BF60-0AA0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Parameters/address space 4 Interrupts/diagnostics alarms 5 Technical specifications 6 A Parameter data record 02/2014 A5E32855878-AA

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY A5E32855878-AA P 02/2014 Technical data subject to change Copyright Siemens AG 2014. All rights reserved

Preface Purpose of the documentation This device manual complements the system manual ET 200SP distributed I/O system (http://support.automation.siemens.com/ww/view/en/58649293). Functions that generally relate to the system are described in this manual. The information provided in this manual and in the system/function manuals supports you in commissioning the system. Conventions Please also observe notes marked as follows: Note A note contains important information on the product described in the documentation, on the handling of the product and on the section of the documentation to which particular attention should be paid. Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. You can find more information about industrial security on the Internet (http://www.siemens.com/industrialsecurity). To stay informed about product updates as they occur, sign up for a product-specific newsletter. You can find more information on the Internet (http://support.automation.siemens.com). Manual, 02/2014, A5E32855878-AA 3

Table of contents Preface... 3 1 Documentation guide... 5 2 Product overview... 6 2.1 Properties... 6 3 Wiring... 8 3.1 Pin assignment... 8 3.2 Block diagram... 9 4 Parameters/address space... 10 4.1 Parameters... 10 4.2 Explanation of parameters... 11 4.3 Address space... 11 5 Interrupts/diagnostics alarms... 12 5.1 Status and error displays... 12 5.2 Interrupts... 14 5.3 Diagnostics alarms... 14 6 Technical specifications... 15 6.1 Technical specifications... 15 A Parameter data record... 18 A.1 Parameter assignment and structure of parameter data record... 18 Manual, 02/2014, A5E32855878-AA 4

Documentation guide 1 Introduction The documentation of the SIMATIC products has a modular structure and covers topics relating to your automation system. The complete documentation for the ET 200SP distributed I/O system consists of the system manual, function manuals and device manuals. The STEP 7 information system (online help) also helps you to configure and program your automation system. Overview of the documentation for digital output module DQ 8 24VDC/0,5A SNK BA The table below lists additional documentation that you will need when using the DQ 8 24VDC/0,5A SNK BA digital output module. Table 1-1 Documentation for digital output module DQ 8 24VDC/0,5A SNK BA Topic Documentation Most important contents System description BaseUnits Enhancements and special features of the ET 200SP Distributed I/O System System manual ET 200SP distributed I/O system (http://support.automation.siemens.co m/ww/view/en/58649293) Manual ET 200SP BaseUnits (http://support.automation.siemens.co m/ww/view/en/59753521) Product information Amendments to ET 200SP documentation (http://support.automation.siemens.co m/ww/view/en/73021864) Application planning Installation Wiring Commissioning Technical specifications Current information not yet documented in the system manuals, function manuals, or other manuals. SIMATIC manuals All of the current manuals for SIMATIC products are available for download free of charge from the Internet (http://www.siemens.com/simatic-tech-doku-portal). Manual, 02/2014, A5E32855878-AA 5

Product overview 2 2.1 Properties Part number 6ES7132-6BF60-0AA0 View of the module Figure 2-1 View of the DQ 8 24VDC/0,5A SNK BA module Manual, 02/2014, A5E32855878-AA 6

Product overview 2.1 Properties Properties The module has the following technical properties: 8 digital outputs Sink output (NPN, M switching) Supply voltage L+ Output current 0.5 A (per channel) Configurable diagnostics (per module) Suitable for solenoid valves, DC contactors, and indicator lights The module supports the following functions: Firmware update Identification data I&M0 to I&M3 Parameter assignment in RUN You can configure the module with STEP 7 (TIA Portal) and with a GSD file. Accessories The following accessories are supplied with the module and can also be ordered separately as spare parts: Labeling strips Color identification labels Reference identification label Shield connector See also You can find additional information on the accessories in the ET 200SP Distributed I/O System (http://support.automation.siemens.com/ww/view/en/58649293) system manual. Manual, 02/2014, A5E32855878-AA 7

Wiring 3 3.1 Pin assignment General pin assignment The following table shows the pin assignment for DQ 8 24VDC/0,5A SNK BA. Table 3-1 Pin assignment for DQ 8 24VDC/0,5A SNK BA Terminal Pin assignment for DQ 8 24VDC/0,5A SNK BA (6ES7132-6BF00-0BA0) Terminal Assignment Assignment 1 DQ0 2 DQ1 DQn: Output signal, channel n 3 DQ2 4 DQ3 5 DQ4 6 DQ5 Description BaseUnit 1 Color identification label (terminals 1 to 16) L+: Actuator supply A0 7 DQ6 8 DQ7 9 L+ 10 L+ 11 L+ 12 L+ 13 L+ 14 L+ 15 L+ 16 L+ L+ 24 V DC M M 2-wire CC01 6ES7193-6CP01-2MA0 1 BaseUnit types that can be used are identified by the last two digits of the part number. See also "ET 200SP distributed I/O system" system manual. Note The first BaseUnit of an ET 200SP station must be a light-colored BaseUnit. Keep this in mind also during the configuration. See also ET 200SP distributed I/O system (http://support.automation.siemens.com/ww/view/en/58649293) Manual, 02/2014, A5E32855878-AA 8

Wiring 3.2 Block diagram 3.2 Block diagram Block diagram The figure below shows the block diagram of the DQ 8x24VDC/0,5A SNK BA. Figure 3-1 Block diagram DQ 8 24VDC/0,5A SNK BA Manual, 02/2014, A5E32855878-AA 9

Parameters/address space 4 4.1 Parameters DQ 8x24VDC/0,5A SNK BA parameters Specify the module properties with the various parameters in the course of your STEP 7 configuration. The following table lists the configurable parameters. The effective range of the configurable parameters depends on the type of configuration. The following configurations are possible: Distributed operation on PROFINET IO in an ET 200SP system Distributed operation on PROFIBUS DP in an ET 200SP system When assigning parameters in the user program, use the "WRREC" instruction to transfer the parameters to the module by means of data records (see chapter Parameter assignment and structure of the parameter data record (Page 18)). Table 4-1 Configurable parameters and their defaults (GSD file) Parameter Value range Default Reconfiguration in RUN Scope with configuration software, e.g., STEP 7 (TIA Portal) Diagnostics No supply voltage L+ Disable Enable GSD file PROFINET IO GSD file PROFIBUS DP 1 Disable Yes Module Module Channel activated Disable Enable Yes Channel Channel Enable Reaction to CPU STOP Turn off Keep last value Output substitute value 1 Potential group Use potential group of the left module Enable new potential group Turn off Yes Channel Module (reaction) Channel (substitute value) Use potential No Module Module group of the left module 1 Only when configuring using a PROFIBUS GSD file; does not apply to configuration with STEP 7 via HSP. The parameter assignment options are limited because PROFIBUS GSD configuration limits the number of parameters to a maximum of 244 bytes for each ET 200SP station. If required, you can still assign these parameters using the data record 128 as described in the column "GSD file PROFINET IO" (see table above). The parameter length of the I/O module is 4 bytes. Manual, 02/2014, A5E32855878-AA 10

Parameters/address space 4.2 Explanation of parameters 4.2 Explanation of parameters Diagnostics: No supply voltage L+ Enabling of the diagnostics for no or insufficient supply voltage L+. Operating mode Determines whether a channel is activated or deactivated. Reaction to CPU STOP Determines the behavior of the module in the event of a CPU STOP. Potential group Specifies whether a BaseUnit with incoming voltage supply is located on this slot. Principle ET 200SP distributed I/O system (http://support.automation.siemens.com/ww/view/en/58649293) 4.3 Address space Address space of the digital output module DQ 8 24VDC/0,5A SNK BA The figure below shows the assignment of the address space for DQ 8 24VDC/0,5A SNK BA. Figure 4-1 Address space of the digital output module DQ 8 24VDC/0,5A SNK BA Manual, 02/2014, A5E32855878-AA 11

Interrupts/diagnostics alarms 5 5.1 Status and error displays LED displays The figure below shows the LED displays (status and error displays) of the DQ 8x24VDC/0,5A SNK BA. 1 2 3 DIAG (green/red) Channel status (green) PWR (green) Figure 5-1 LED displays Manual, 02/2014, A5E32855878-AA 12

Interrupts/diagnostics alarms 5.1 Status and error displays Meaning of the LED displays The tables below explain the meaning of the Status and error displays. Remedial measures for diagnostics alarms can be found in section Diagnostics alarms (Page 14). LED DIAG Table 5-1 Error display of the LED DIAG LED DIAG Off Flashes On Flashes Meaning Backplane bus supply of the ET 200SP not OK Module parameters not assigned Module parameters assigned and no module diagnostics Module parameters assigned and module diagnostics LED channel status Table 5-2 Status display of the LED channel status LED channel status Meaning Channel deactivated or activated and process signal = 0 Off Channel activated and process signal = 1 On LED PWR Table 5-3 Status display of the LED PWR LED PWR Off On Meaning No supply voltage L+ Supply voltage L+ present Manual, 02/2014, A5E32855878-AA 13

Interrupts/diagnostics alarms 5.2 Interrupts 5.2 Interrupts The DQ 8 24VDC/0,5A SNK BA digital output module supports diagnostics alarms. Diagnostics interrupts The module generates a diagnostic interrupt at the following event: No supply voltage Detailed information on the event is available in the STEP 7 online help. 5.3 Diagnostics alarms Diagnostics alarms A diagnostics alarm is output for each diagnostics event and the LED DIAG flashes on the module. The diagnostics alarms can, for example, be read from the diagnostics buffer of the CPU. You can evaluate the error codes with the user program. Table 5-4 Diagnostics alarms, their meaning and corrective measures Diagnostics alarm Error code Meaning Remedy No supply voltage 11H No or insufficient supply voltage L+ Check supply voltage L+ on the BaseUnit Check BaseUnit type 14 Manual, 02/2014, A5E32855878-AA

Technical specifications 6 6.1 Technical specifications Technical specifications of the DQ 8 24VDC/0,5A SNK BA Product type designation General information Usable BaseUnits Product function I&M data Engineering with STEP 7 TIA Portal can be configured/integrated as of version 6ES7132-6BF60-0AA0 DQ 8x24VDC/0,5A SNK BA BU type A0 Yes; I&M0 to I&M3 V13 / V13 STEP 7 can be configured/integrated as of version V5.5 SP3 / V5.5 SP4 PROFIBUS as of GSD version/gsd revision GSD revision 5 PROFINET as of GSD version/gsd revision V2.3 / - Operating mode Multi-output Oversampling MSI MSO Supply voltage Rated value (DC) Valid range low limit (DC) Valid range high limit (DC) Output voltage Rated value (DC) Power loss Power loss, typ. Address area Address space per module Address space per module, max. Output No No No No 24 V 19.2 V 28.8 V 24 V 1.5 W 1 bytes 1 bytes Manual, 02/2014, A5E32855878-AA 15

Technical specifications 6.1 Technical specifications 6ES7132-6BF60-0AA0 Digital outputs Number of outputs 8 Switching to M potential Short-circuit protection Yes Yes Response threshold, typ. 1.5 A Wire-break detection Limitation of inductive shutdown voltage to Controlling a digital input Switching capacity of outputs With resistive load, max. With lamp load, max. Load resistance range Low limit High limit Output current for signal "1" rated value No Typ. 47V Yes 0.5 A 5 W 48 Ω 3400 Ω 0.5 A for signal "0" residual current, max. 5 µa Output delay with resistive load "0" to "1", max. 300 µs "1" to "0", max. 600 µs Parallel switching of 2 outputs For increased performance For redundant control of a load Switching frequency With resistive load, max. With inductive load, max. With lamp load, max. Total current of the outputs Max. current per channel Max. current per module Isochronous mode Isochronous mode (application synchronized up to terminal) Interrupts/diagnostics/status information Diagnostics alarms Diagnostics Monitoring of supply voltage Diagnostics indicator LED Monitoring of supply voltage Channel status display For module diagnostics No Yes 100 Hz 0.5 Hz 10 Hz 0.5 A 4 A No Yes Yes Yes; green LED PWR Yes; green LED Yes; green/red LED DIAG 16 Manual, 02/2014, A5E32855878-AA

Technical specifications 6.1 Technical specifications 6ES7132-6BF60-0AA0 Electrical isolation Electrical isolation channels Between the channels Between the channels and the backplane bus Permissible potential difference Between different circuits Isolation Isolation tested with Dimensions Width Weights Weight, approx. No Yes 75 V DC / 60 V AC (basic isolation) 707 V DC (type test) 15 mm 30 g Dimensional drawing See the manual ET 200SP BaseUnits (http://support.automation.siemens.com/ww/view/en/58532597/133300) Manual, 02/2014, A5E32855878-AA 17

Parameter data record A A.1 Parameter assignment and structure of parameter data record The data records of the module have an identical structure, regardless of whether you configure the module with PROFIBUS DP or PROFINET IO. Parameter assignment in the user program You have the option to re-configure the module in RUN (e.g. the response of selected channels to the CPU-STOP state can be changed in RUN without having an effect on the other channels). Changing parameters in RUN The "WRREC" instruction is used to transfer the parameters to the module using data record 128. The parameters set in STEP 7 are not changed in the CPU, which means the parameters set in STEP 7 will be valid again after a restart. Output parameter STATUS The module ignores errors that occur during the transfer of parameters with the "WRREC" instruction and continues operation with the previous parameter assignment. However, a corresponding error code is written to the STATUS output parameter. The description of the "WRREC" instruction and the error codes is available in the STEP 7 online help. Manual, 02/2014, A5E32855878-AA 18

Parameter data record A.1 Parameter assignment and structure of parameter data record Structure of data record 128 Note Channel 0 includes the diagnostics for the entire module. Figure A-1 Structure of data record 128 Header information The figure below shows the structure of the header information. Figure A-2 Header information Manual, 02/2014, A5E32855878-AA 19

Parameter data record A.1 Parameter assignment and structure of parameter data record Parameters The figure below shows the structure of the parameters for channels 0 to 7. Enable a parameter by setting the corresponding bit to "1". Figure A-3 Structure byte x to x+1 for the channels 0 to 7 20 Manual, 02/2014, A5E32855878-AA