SIMATIC. ET 200S distributed I/O 2AI U ST analog electronic module (6ES7134-4FB01-0AB0) Preface. Properties 1. Parameters 2.
|
|
|
- Lucas Daniel Walsh
- 9 years ago
- Views:
Transcription
1 SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AI U ST analog electronic module (6ES7134-4FB01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation 4 Connecting 5 04/2007 A5E
2 Safety Guidelines Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE Qualified Personnel Prescribed Usage Trademarks indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards. Note the following Disclaimer of Liability WARNING This device may only be used for the applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and assembly as well as careful operation and maintenance. All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Automation and Drives Postfach NÜRNBERG GERMANY Ordernumber A5E P 09/2007 Copyright Siemens AG Technical data subject to change
3 Preface Purpose of the manual This manual supplements the ET 200S Distributed I/O System Operating Instructions. General functions for the ET 200S are described in the ET 200S Distributed I/O System Operating Instructions. The information in this document along with the operating instructions enables you to commission the ET 200S. Basic knowledge requirements To understand these operating instructions you should have general knowledge of automation engineering. Scope of the manual This manual applies to this ET 200S module. It describes the components that are valid at the time of publication. Recycling and disposal Thanks to the fact that it is low in contaminants, this ET 200S module is recyclable. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste. Additional support If you have any questions relating to the products described in these operating instructions, and do not find the answers in this document, please contact your local Siemens representative. http// The portal to our technical documentation for the various SIMATIC products and systems is available at http// The online catalog and ordering system are available at http// Manual, 04/2007, A5E
4 Preface Training center We offer courses to help you get started with the ET 200S and the SIMATIC S7 automation system. Please contact your regional training center or the central training center in D , Nuremberg, Germany. Phone +49 (911) http// Technical Support You can reach technical support for all A&D projects using the support request web form http// Phone Fax For more information about our technical support, refer to our Web site at http// Service & Support on the Internet In addition to our documentation services, you can also make use of our comprehensive online knowledge base on the Internet. http// There you will find Our Newsletter, which constantly provides you with the latest information about your products. The right documentation for you using our Service & Support search engine. The bulletin board, a worldwide knowledge exchange for users and experts. Your local contact for Automation & Drives in our contact database. Information about on-site services, repairs, spare parts. Lots more can be found on our "Services" pages. 4 Manual, 04/2007, A5E
5 Table of contents Preface Properties Parameters Parameters Parameter description Diagnostics Diagnostics using LED display Error types Analog value representation Introduction Analog value representation for measuring range with SIMATIC S Measuring ranges Effect on analog value representation Effect of the supply voltage and the operating state on analog input values Effect of the value range on the 2AI U ST analog input Connecting Connecting measuring sensors Wiring unused channels of the analog input modules Using the shield connection...22 Index Manual, 04/2007, A5E
6 Table of contents 6 Manual, 04/2007, A5E
7 Properties Properties 2 inputs for measuring voltage Input ranges ± 10 V, resolution 13 bits + sign ± 5 V, resolution 13 bits + sign 1 V to 5 V, resolution 13 bits Isolated from the load voltage L+ Permissible common mode voltage 2 VACSS Extended temperature range from 0 to 50 C with vertical installation General terminal assignment Note Terminals 4, 8, A4, A8, A3 and A7 are only available at specified terminal modules. Terminal assignment for 2AI U ST (6ES7134-4FB01-0AB0) Terminal Assignment Terminal Assignment Notes 1 M0+ 5 M1+ Mn+ Input signal "+", channel n 2 M0-6 M1- Mn- Input signal "-", channel n 3 Mana 7 Mana Mana Ground of the module 4 n.c. 8 n.c. n.c. Not connected (max. 30 V DC can be connected) A4 AUX1 A8 AUX1 AUX1 Protective-conductor terminal or potential bus (freely usable up to 230 VAC) A3 AUX1 A7 AUX1 Manual, 04/2007, A5E
8 Properties 1.1 Usable terminal modules TM-E15C26-A1 (6ES7193-4CA50-0AA0) TM-E15S26-A1 (6ES7193-4CA40-0AA0) TM-E15N26-A1 (6ES7193-4CA80-0AA0) TM-E15C24-A1 (6ES7193-4CA30-0AA0) TM-E15S24-A1 (6ES7193-4CA20-0AA0) TM-E15N24-A1 (6ES7193-4CA70-0AA0) Usable terminal modules for 2AI U ST (6ES7134-4FB01-0AB0) TM-E15C24-01 (6ES7193-4CB30-0AA0) TM-E15S24-01 (6ES7193-4CB20-0AA0) TM-E15N24-01 (6ES7193-4CB70-0AA0) TM-E15C23-01 (6ES7193-4CB10-0AA0) TM-E15S23-01 (6ES7193-4CB00-0AA0) TM-E15N23-01 (6ES7193-4CB60-0AA0) Spring terminal Screw-type terminal Fast Connect Block diagram Figure 1-1 Block diagram of the 2AI U ST 8 Manual, 04/2007, A5E
9 Properties 1.1 2AI U ST technical specifications (6ES7134-4FB01-0AB0) Dimensions and weight Width (mm) 15 Weight Supports isochronous operation Approx. 40 g Module-specific data Number of inputs 2 Cable length Shielded Max. 200 m Parameter length Address space Rated load voltage L+ (from the power module) No 4 bytes 4 bytes Voltages, currents, potentials Reverse polarity protection Yes Electrical isolation Between the channels and backplane bus Yes Between the channels and load voltage L+ Yes Between the channels No Permissible potential difference 24 VDC Between the inputs and MANA (UCM) 2 VACSS Between MANA and the central grounding point (UISO) Insulation tested Current consumption 75 VDC / 60 VAC 500 VDC From load voltage L+ Max. 30 ma Power dissipation of the module Diagnostics function Typically 0.6 W Status, interrupts, diagnostics Group error Red "SF" LED Diagnostic functions readable Yes Measuring principle Integration and cycle time/resolution per channel Analog value generation Integration time can be assigned parameters Yes Integrative Interference frequency suppression in Hz Integration time in ms 16,7 20 Conversion time in ms Cycle time in ms Number of active channels per module x conversion time Resolution (including overshoot range) ± 10 V/13 bits + sign ± 5 V/13 bits + sign 1 V to 5 V/13 bits Manual, 04/2007, A5E
10 Properties 1.1 Suppression of interference, limits of error Interference voltage suppression for f = n x (f1 ± 1 %), (f1 = interference frequency) Common-mode interference (USS) Series-mode interference (peak interference value < rated value of input range) Crosstalk between the inputs Operational limit (in the entire temperature range, with reference to the input range) Basic error limit (operational limit at 25 C with reference to input range) Temperature error (with reference to the input range) Min. 90 db min. 70 db min. -50 db ± 0,6 % ± 0,4 % ±0.01 %/K Linearity error (with reference to the input range) ± 0,01 % Repeatability (in steady state at 25 C with ± 0,05 % reference to input range) Data for selecting a sensor Input range (rated value)/input resistance Voltage ± 5 V/min. 100 kω 1 V to 5 V/min.100 kω ± 10 V/min. 100 kω Permitted input voltage (destruction limit) 35 V continuous, 75 V at max. duration of 1 ms (sampling ratio 120) Smoothing of the measured values Yes, can be assigned parameters in 4 steps by means of digital filtering Step None Weak Medium Strong Time constant 1 x cycle time 4 x cycle time 32 x cycle time 64 x cycle time 10 Manual, 04/2007, A5E
11 Parameters Parameters Table 2-1 Parameters for analog input module 2 AI U ST Range of values Default setting Applicability Group diagnostics (parameter Disable assignment error, internal error) Enable Diagnostics Overflow/underflow Disable Enable Diagnostics Wire break* Disable Enable Smoothing None Weak Medium Strong Type/range of measurement Deactivated ±5 V ±10 V 1 to 5 V * Only in the measuring range of 1 to 5 V Disable Module Disable Module Disable Channel None Channel ±10 V Channel Manual, 04/2007, A5E
12 Parameters 2.2 Parameter description 2.2 Parameter description Smoothing The individual measured values are smoothed by digital filtering. The smoothing can be adjusted in four steps, in which the smoothing factor k multiplied with cycle time of the electronic module equals the time constant of the smoothing filter. The greater the smoothing, the greater the time constant of the filter. The figure below shows the step response with the various smoothing factors in relation to the number of subassembly cycles. Figure 2-1 Smoothing with the 2AI U ST 12 Manual, 04/2007, A5E
13 Diagnostics Diagnostics using LED display LED display 1 1 Batch error (red) Status and error displays Event (LED) SF On Cause No configuration or incorrect module plugged in. No load voltage.present There is a diagnostic message. Remedy Check the parameter assignment. Check the load voltage. Evaluate the diagnostics. Manual, 04/2007, A5E
14 Diagnostics 3.2 Error types 3.2 Error types Analog input module error types Table 3-1 Error types 16D Error type Meaning Remedy Parameter assignment error Module cannot use the parameter for the channel Inserted module does not match the one configured. Incorrect parameter assignment. 9D Error Internal module error (diagnostic message at channel 0 applies to the entire module) 7D Upper limit exceeded 8D Lower limit value undershot 6D Open circuit Value is above the overshoot range. Value is below the underrange. Line to the encoder interrupted. Correct the configuration (align actual and set configuration). Correct the parameter assignment (wire break diagnostics only parameterized for the permitted measuring ranges). Replace the module. Correct the module/final controlling element tuning. Correct the module/final controlling element tuning. Correct the process wiring. 14 Manual, 04/2007, A5E
15 Analog value representation Introduction Electronic modules with analog outputs With the electronic module with analog inputs, continuously variable signals, such as those occurring in temperature measurement and resistance measurement, can be acquired, evaluated, and converted to digital values for further processing. 4.2 Analog value representation for measuring range with SIMATIC S7 Analog value representation With the same nominal range, the digitized analog value is the same for input and output values. Analog values are represented in two's complement. The following table shows the analog value representation of the analog electronic modules. Table 4-1 Analog value representation (SIMATIC S7 format) Resolution Analog value Bit number Significance of the bits S Sign The sign (S) of the analog value is always in bit number 15 "0" + "1" Manual, 04/2007, A5E
16 Analog value representation 4.3 Measuring ranges Output value The following table shows the representation of the binary analog values and the corresponding decimal and hexadecimal representation of the units of the analog values. The table below shows the resolutions 11, 12, 13, and 15 bit + sign. Each analog value is entered left aligned in the ACCU. The bits marked with "x" are set to "0". Table 4-2 Output values (SIMATIC S7 format) Resolution in bits Units Analog value Decimal Hexadecimal High byte Low byte 11+S 16 10H S x x x x 12+S 8 8H S x x x 13+S 4 4H S x x 15 + sign 1 1H S Measuring ranges Introduction The following tables contain the digitized analog values for the measuring ranges of the analog input modules. Since the binary representation of the analog values is always the same, these tables only compare the measuring ranges with the units. Voltage measuring ranges ±5 V, ±10 V Table 4-3 SIMATIC S7 format Measuring ranges ±5 V and ±10 V Measuring range ±5 V Measuring range Units ±10 V Decimal Hexadecimal Range > 5,8794 > 11, FFFH Overflow 5, , EFFH Overshoot range 5, , C01H 5,00 3,75 10,00 7, C00H 5100H Nominal range -3,75-5,00-7,50-10, AF00H 9400H -5, , FFH Underrange -5, , H < -5,8796 < -11, H Underflow 16 Manual, 04/2007, A5E
17 Analog value representation 4.3 Measuring ranges Voltage measuring ranges 1 to 5 V Table 4-4 SIMATIC S7 format Measuring range 1 to 5 V Measuring range 1 to 5 V Decimal Units Hexadecimal > 5, FFFH Overflow 5, EFFH 5, C01H 5, C00H 4, H Nominal range 1, H 0, FFFFH Underrange 0, ED00H < 0, H Underflow Range Overshoot range Measured values in the event of a wire break in relation to enabled diagnostics The following additional information applies to the voltage measuring range 1 to 5 V Table 4-5 Measured values in the event of a wire break in relation to enabled diagnostics Format Parameter assignment 1 Measured values Description Decimal Hexadecimal S7 "Wire break" diagnostics enabled FFFH "Open circuit" diagnostic message "Wire break" diagnostics disabled H Measured value after leaving the underrange "Overflow/underflow" diagnostics enabled "Wire break" diagnostics disabled "Overflow/underflow" diagnostics disabled 1 Measuring range limits for wire break and underflow detection At V "Lower limit value undershot" diagnostic message H Measured value after leaving the underrange Manual, 04/2007, A5E
18 Analog value representation 4.4 Effect on analog value representation 4.4 Effect on analog value representation Effect of the supply voltage and the operating state on analog input values The input values of the analog modules are dependent on the supply voltage for electronics/encoders and on the operating state of the PLC (CPU of the DP master). This is illustrated by the table below. Table 4-6 Relationship between the analog input values for the operating state of the PLC (CPU of the DP master) and the supply voltage L+ Operating state of the PLC (CPU of the DP master) POWER ON RUN Supply voltage L+ on ET 200S (power module) L+ present Input value of the electronic module with analog inputs (evaluation possible on the CPU of the DP master) Process values 7FFFH until first conversion after startup, or after assignment of parameters for the module is completed. POWER ON STOP L+ missing 7FFFH L+ present Process value POWER OFF - L+ missing 7FFFH L+ present - L+ missing Effect of the value range on the 2AI U ST analog input The way electronic modules respond to analog inputs depends on where the input values fall within the value range. This is illustrated by the table below. Table 4-7 Response of the analog modules, depending on where the analog input value falls within the range of values Measured value within... Input value in SIMATIC S7 format Input value in SIMATIC S5 format Nominal range Measured value Measured value Over-/underrange Measured value Measured value Overflow 7FFFH End of the overshoot range +1 plus overflow bit Underflow 8000H End of the underrange -1 plus overflow bit Prior to parameter assignment, or with incorrect parameter assignment * 7FFFH 7FFFH * With product version 1 of the 2 AI U ST, the following applies If the parameter setting error diagnostic message is triggered because the parameters have been assigned incorrectly (e.g., wire break in measuring range ± 20 ma), the SF LED on the module lights up and the diagnostics can be evaluated. With this status, the correct input values are sent to the DP master. 18 Manual, 04/2007, A5E
19 Connecting Connecting measuring sensors Introduction You can connect encoders with voltage signals to the 2AI U ST analog input module. In this chapter you will find out how to connect the measuring encoders and what to watch out for when doing so. Cables for analog signals You should use shielded and twisted-pair cables for the analog signals. This reduces the effect of interference. You should ground the shield of the analog cables at both ends. If there are differences in potential between the cable ends, an equipotential bonding current that may interfere with the analog signals will flow across the shield. If this is the case, you should only ground the shield at one end of the cable. Analog input modules The analog input modules are electrically isolated Between the logic and backplane bus Between the load voltage and the channels. Electrical isolation No link between MANA and the central grounding point (UISO) Note Ensure that this difference in potential UISO does not exceed the permitted value. If there is a possibility of exceeding the permitted value, establish a connection between terminal MANA and the central grounding point. Connecting measuring encoders to analog inputs There can be only a limited potential difference UCM (common mode) between the measuring lines M- of the input channels and the reference point of the measuring circuit MANA. To ensure that the permitted value is not exceeded, you must take different steps depending on the whether the encoders are isolated or non-isolated. The steps you have to take are described in this chapter. Manual, 04/2007, A5E
20 Connecting 5.1 Connecting measuring sensors Abbreviations used The meanings of the abbreviations in the figures below are as follows M+ Measuring line (positive) M- Measuring line (negative) MANA Analog measuring circuit reference potential M Ground connection L+ Rated load voltage 24 V DC UCM Potential difference between inputs and reference potential of the measuring circuit MANA UISO Potential difference between MANA and central grounding point Isolated measuring encoders The isolated measuring encoders are not connected to the local ground potential. These can be potential-free. Depending on local conditions or interference, potential differences UCM (static or dynamic) can occur between the measuring lines M- of the input channels and the reference point of the measuring circuit MANA. To ensure that the permitted value for UCM is not exceeded in environments with strong EMC interference, the following applies For the 2 AI U analog input module Connect M- to MANA! The following schematic representation illustrates the connection of isolated measuring encoders to the optically isolated analog input modules Logic Backplane bus Ground bus Central grounding point Isolated measuring encoders 20 Manual, 04/2007, A5E
21 Connecting 5.1 Connecting measuring sensors Non-isolated measuring encoders The non-isolated measuring encoders are connected to the local ground potential. You must connect MANA to the ground potential. Depending on local conditions or interference, potential differences UCM (static or dynamic) can occur between the locally distributed measuring points. If the permitted value for UCM is exceeded, there must be equipotential bonding conductors between the measuring points. The following schematic representation illustrates the connection of non-isolated measuring encoders to an optically isolated analog input module Logic Backplane bus Ground bus Equipotential bonding conductor Non-isolated measuring encoders Manual, 04/2007, A5E
22 Connecting 5.2 Wiring unused channels of the analog input modules 5.2 Wiring unused channels of the analog input modules Rules Pay attention to the following instructions when wiring unused channels "Deactivate" unused input channels when assigning parameters. A deactivated channel always returns the value 7FFFH. The module cycle time is halved with the 2 AI U ST module. To adhere to the permissible potential differences (UCM), you must wire jumpers on the terminal module for the unused channels. 2 AI U ST Analog input module TM connecting terminal Channel 0 Channel Using the shield connection Rules To prevent interference we recommend the following for analog electronic modules Use shielded wires to the sensors and actuators. Lay out the wire shields on the shield connection. Connect the shield connection to the ground bus with low impedance. 22 Manual, 04/2007, A5E
23 Index 2 2A U ST analog electronic module Technical specifications, 9 2AI U ST analog electronic module Block diagram, 8 Properties, 7 Terminal assignment, 7 A Analog input modules Error types, 14 Analog value processing, 19 B Basic knowledge requirements, 3 C Cables for analog signals, 19 Connecting, 19 Connecting measuring encoders to analog inputs, 19 D Disposal, 3 I Internet Service & Support, 4 Isolated measuring encoders, 20 M Measured value resolution, 16 Measuring encoders, 19 Measuring ranges with SIMATIC S7, 15 N Non-isolated measuring encoders, 21 P Parameters For analog electronic modules, 11 R Recycling, 3 Response of the analog modules, 18 During operation, 18 When faults occur, 18 S Scope Manual, 3 Service & Support, 4 Shield connection, 22 Smoothing, 12 T Technical Support, 4 Training center, 4 L LED display, 13 Manual, 04/2007, A5E
24 Index 24 Manual, 04/2007, A5E
SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.
SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation
SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.
SIMATIC ET 200S distributed I/O SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Manual 04/2007 A5E01077339-01 Safety Guidelines
SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.
SIMATIC ET 200S distributed I/O SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Manual 04/2007 A5E01077385-01 Safety Guidelines
CPU 317-2 PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device
CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device SIMATIC PROFINET CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device Introduction 1 Preparation 2 Learning units 3 Further Information
SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves
SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300
SIMATIC SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300 Manual Preface, Contents Characteristics and Technical Specifications of the SM 335 Connecting the Inputs and Outputs of the
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
SIMATIC S7-300. Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01
SIMATIC S7-300 Getting Started for First Time Users Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01 Safety Guidelines This manual contains notices you have to observe in order to ensure your personal
SIMATIC HMI. WinCC flexible 2008 Getting Started - First-Time Users Getting Started. Printout of the Online Help 06/2008 A5E00279548-04
SIMATIC HMI WinCC flexible 2008 Getting Started - First-Time Users Getting Started Printout of the Online Help 06/2008 A5E00279548-04 Safety Guidelines This manual contains notices you have to observe
Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Programming and Operating Manual
Validity 1 Improvements in STEP 7 2 SIMATIC Improvements in WinCC 3 Readme Programming and Operating Manual 07/2013 Legal information Warning notice system This manual contains notices you have to observe
Fieldbus slave modules with I/Os, DIO
140 Fieldbus slave modules with I/Os, DIO 1534CF00 1534CH00 1534PF00 1534PH00 1536CH00 1536CL10 1536PH00 1536PL00 Order number 1534CF00 1534CH00 1534PF00 1534PH00 Figure Type SM 153, CANopen slave, DIO
Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20
Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation
DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) SIMATIC. S7-1500/ET 200MP DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) Preface
DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) SIMATIC S7-1500/ET 200MP DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) Manual Preface Documentation guide 1 Product overview 2 Wiring
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
SIMATIC. S7 300 PLC CPU 317T-2 DP: Controlling a virtual axis. Introduction. Preparation. Learning units 3. Further information 4.
Introduction 1 Preparation 2 SIMATIC S7 300 PLC CPU 317T-2 DP: Controlling a virtual axis Learning units 3 Further information 4 Getting Started 12/2005 A5E00266292-03 Safety Guidelines This manual contains
2 Counter Module SIMATIC. S7-300 FM 350-2 Counter module. Preface. Product Overview. How the FM 350-2 Counts 2. Installing and Removing the FM 350-
FM 350-2 Counter Module Preface Product Overview 1 SIMATIC S7-300 Manual How the FM 350-2 Counts 2 Installing and Removing the FM 350-2 3 Wiring the FM 350-2 4 Assigning Parameters to the FM 350-2 5 Programming
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5
SIMATIC WinCC V7.0 SIMATIC WinCC V7.0 Printout of the Online Help 1 Welcome 2 Icons 3 Creating a project 4 Configure communication 5 Configuring the Process Screens 6 Archiving and displaying values 7
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
SIMATIC. ET 200S distributed I/O IM151-1 STANDARD interface module (6ES7151-1AA05-0AB0) Preface. Properties 1. Parameters 2.
Preface SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O IM151-1 STANDARD interface module (6ES7151-1AA05-0AB0) Manual Properties 1 Parameters 2 Functions 3 Interrupt, error, and system
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks
Loading the block library 1 Deleting program block Main [OB1] 2 TIA Portal SIMATIC Getting Started Copying program blocks 3 Cyclic interrupt OB 4 Copying tag tables 5 Compiling a project 6 Load project
Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A
COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850
6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A
6ES7314-6CG03-0AB0 Page 1 Product data sheet 6ES7314-6CG03-0AB0 SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED
6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A
6ES7313-5BF03-0AB0 Page 1 Product data sheet 6ES7313-5BF03-0AB0 SIMATIC S7-300, CPU 313C, COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO 1 PT100, 3 FAST COUNTERS (30 KHZ), INTEGRATED 24V DC POWER SUPPLY,
ABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
SIMATIC. S7-300 and M7-300 Programmable Controllers Module Specifications. Preface, Contents. General Technical Specifications. Power Supply Modules
SIMATIC S7-300 and M7-300 Programmable Controllers Module Specifications Reference manual This manual is part of the following documentation packages with order nos: S7 300 Programmable Controller: 6ES7
Allen-Bradley/Rockwell
MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:
MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives. Load-balanced control application
SINAMICS DCM DC converters from 6 kw to 2500 kw for variable-speed direct-current drives Edition 01-12/2010 SINAMICS drives SINAMICS DCM Compact User Manual Legal information Warning notice system This
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
DANGER indicates that death or severe personal injury will result if proper precautions are not taken.
SIMATIC Process Control System PCS 7 V7.0 SP1 SIMATIC Process Control System PCS 7 V7.0 SP1 Preface 1 PC components of a PCS 7 system 2 Hardware for PC stations 3 Installing PC stations 4 Appendix 5 Operating
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Validity 1. Installation 2 SIMATIC. WinCC flexible Tag simulator Update 1. Readme
Validity 1 Installation 2 SIMATIC WinCC flexible Readme 05/2011 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well
DANGER indicates that death or severe personal injury will result if proper precautions are not taken.
Basic Settings 1 Configuring the firewall 2 SIMATIC HMI Configuring DCOM 3 Configuring DCOM Machine Default 4 Using OPC via DCOM with Windows XP SP3 Readme 01/2010 Safety Guidelines This manual contains
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
Specifications for EM223 24 VDC 4 In/4 Out and EM223 24 VDC 4 In/4 Relay Out
SIMATIC S7-200 EM223 Digital Combination Modules EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out Table 1 Specifications for EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out EM223 2VDC In/Out 6ES7 2231BF200XA0
SIMATIC. SIMATIC Logon. User management and electronic signatures. Hardware and Software Requirements. Scope of delivery 3.
SIMATIC SIMATIC SIMATIC User management and electronic signatures 1 Hardware and Software Requirements 2 Scope of delivery 3 Installation 4 5 Configuration Manual 08/2008 A5E00496669-05 Legal information
JUMPFLEX 857 Series. 0...20 ma 2...10 V. 4...20 ma. Transducers / Relay and Optocoupler Modules
0888-0172/0002-3601 JUMPFLEX 857 Series 2.0 E 12/08 Printed in Germany Subject to design changes 2...10 V 0...20 ma 4...20 ma WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 32385 Minden Hansastraße 27
http://support.automation.siemens.com/ww/view/en/4067870&td=1
6ES7316-2AG00-0AB0 SIMATIC S7-300, CPU 316 Technical / CAx data nmlkji Technical Data nmlkj CAx data As of 2010-01-24 Power supply Input voltage Rated value (DC) permissible range, lower limit (DC) permissible
SIMATIC NET. Functions (FC) and function blocks (FB) for SIMATIC NET S7 CPs. Preface. Overview and general information on working with FCs and FBs
Preface Overview and general information on working with FCs and FBs 1 SIMATIC NET Functions (FC) and function blocks (FB) for SIMATIC NET S7 CPs Programming Manual FCs / FBs for Industrial Ethernet 2
What ensures easy and fast wiring?
What ensures easy and fast wiring? SIMATIC TOP connect: the system cabling for connecting sensors and actuators to SIMATIC S7. Answers for industry. More efficient cabling made easy: SIMATIC TOP connect
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
SIMATIC HMI. WinCC flexible Getting Started First Time User. Order number 6ZB5370-1CL02-0BA2. Edition 04/2006 A5E00279548-03
SIMATIC HMI WinCC flexible Getting Started First Time User Order number 6ZB5370-1CL02-0BA2 Edition 04/2006 A5E00279548-03 Safety Guidelines This manual contains notices which you should observe to ensure
Automation Unit TM 1703 ACP Flexible automation and telecontrol
Automation Unit Flexible automation and telecontrol Power Transmission and Distribution Outstanding performance: Automate simply with Highly complex and yet fully transparent automation solutions are not
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
SIMATIC. Open TCP/IP Communication via Industrial Ethernet. Contents Open TCP/IP Communication via Industrial Ethernet 1. Index.
s Contents Open TCP/IP Communication via Industrial Ethernet 1 SIMATIC Index Open TCP/IP Communication via Industrial Ethernet Manual Edition 12/2005 A5E00711636-01 Safety Guidelines This manual contains
Creating the project and hardware. TIA Portal. SIMATIC Creating the project and hardware. Introduction to the TIA Portal 1. Creating a project
Introduction to the TIA Portal 1 Creating a project 2 TIA Portal SIMATIC Getting Started Creating an S7-1500 CPU 3 Running the hardware detection 4 Creating ET 200 interface modules 5 Networking ET 200
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Information Server Documentation SIMATIC. Information Server V8.0 Update 1 Information Server Documentation. Introduction 1. Web application basics 2
Introduction 1 Web application basics 2 SIMATIC Information Server V8.0 Update 1 System Manual Office add-ins basics 3 Time specifications 4 Report templates 5 Working with the Web application 6 Working
CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008
CAT AVR V2.3 Voltage regulator for generators March 2008 Instruction Manual Warnings WARNING The system should not be installed, operated, serviced or modified except by qualified personnel who understand
CQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4
Present sample project 1 HMI configuration 2 SIMATIC Getting Started Insert HMI device from libraries 3 Configuring HMI connection 4 Configuring system diagnostics 5 Simulating an HMI device 6 05/2014
ABB i-bus EIB Logic Module LM/S 1.1
Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...
EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.
Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the
Disturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
Installation guide H-5500-8554-03-A. HSI hardwired system interface
Installation guide H-5500-8554-03-A HSI hardwired system interface 2008-2011 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
LOGO! LOGO! App V.10. LOGO! app 1. Making basic settings and establishing a connection to LOGO! Using the device overview 3. Creating controls 4
LOGO! app 1 Making basic settings and establishing a connection to LOGO! 2 LOGO! Using the device overview 3 Creating controls 4 Settings and project information 5 Operating Manual 04/2016 A5E38071463-AA
Short-circuit current rating (SCCR) of. industrial control panels. NEC Article 409 and UL 508A
Short-circuit current rating (SCCR) of industrial control panels NEC Article 409 and UL 508A Short-circuit current rating (SCCR) of industrial control panels 1 Introduction 2 Overview of NEC Article 409
SIMATIC. PC Adapter USB. Preface, Contents Properties of the PC Adapter USB 1. Package Components
s SIMATIC Manual Preface, Contents Properties of the 1 Package Components 2 Requirements for Operation 3 Hardware Design of the 4 Working with the 5 on the MPI/DP Network 6 Firmware Update 7 Error Diagnostics
Part 1: User information SIMATIC ET 200B Distributed I/O Station Manual Part 2: Reference information Appendices EWA 4NEB 812 6089-02c Edition 04
Preface, Contents SIMATIC ET 200B Distributed I/O Station Manual Part 1: User information System Overview Technical Description Mechanical and Electrical 3 Installation Configuration and 4 Parameterization
Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1
Introduction 1 Connecting the drive unit to the PC 2 Startdrive SINAMICS Getting Started - SINAMICS Startdrive Getting Started Creating a project 3 Going online and incorporating devices 4 Commissioning
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Non-Isolated Analog Voltage/Current Output module IC695ALG704 provides four configurable voltage or current output channels. Isolated +24 VDC Power
July 2010 PACSystems* RX3i Non-Isolated Analog Output Module with HART Communications, IC695ALG728 Non-Isolated Analog Output Modules, IC695ALG704, IC695ALG708 MODULE OK FIELD STATUS TB IC695ALG708 Q1
SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M
SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M Compact Operating Instructions Legal information Qualified Personnel The product/system described in this documentation
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents
Preface, Contents SIMATIC NET AS-Interface - Introduction and Basics Manual AS-Interface (AS-i) 1 AS- Interface Safety at Work (ASIsafe) 2 AS-i System Components 3 The Master Mode - Commands, Sequence,
Configuration limits for products of the SIMATIC NET PC Software V12 SIMATIC NET. Configuration limits for products of the SIMATIC NET PC Software V12
Configuration limits for products of the SIMATIC NET PC Software V12 Communications partners and configuration limits for HARDNET-PB DP-Base 1 software Configuration limits, SOFTNET-PB DP 2 SIMATIC NET
S7-400H SIMATIC. Fault-tolerant systems S7-400H. Preface 1 Fault-tolerant automation systems. S7-400H setup options 3.
SIMATIC Fault-tolerant systems System Manual 12/2010 A5E00267695-07 Preface 1 Fault-tolerant automation systems 2 setup options 3 Getting Started 4 Assembly of a CPU 41x H 5 Special functions of a CPU
SIMADYN D Digital Control System. Interface module SE21.2. User Manual. Edition 05.95 DK-Nr. 282042
SIMADYN D Digital Control System User Manual Interface module SE21.2 Edition 05.95 DK-Nr. 282042 User Manual, Interface module SE21.2 Edition Edition status 1 Interface module SE21.2 04.91 2 Interface
Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA
Order Number: 8160.UANA Status: V6; 1425.03.2010 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 ANACON UMB ANALOGUE/DIGITAL CONVERTER...
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give
TEA1024/ TEA1124. Zero Voltage Switch with Fixed Ramp. Description. Features. Block Diagram
Zero Voltage Switch with Fixed Ramp TEA04/ TEA4 Description The monolithic integrated bipolar circuit, TEA04/ TEA4 is a zero voltage switch for triac control in domestic equipments. It offers not only
L5354 ControlNet Communications Interface
L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or
IO-DIM6 6-Channel, Digital to Analogue Converters
Page 1 of 6 IO-DIM6 6-Channel, Digital to Analogue Converters Features: Benefits: Input status indication Calibrated output DIN Rail mounting Expands controller input capacity Fault finding LED indication
EXTERNAL DIMENSIONS AND PARTS
FX2N-4DA SPECIAL FUNCTION BLOCK USER S GUIDE JY992D65901A This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4DA special
IRT Eurocard. Types DAX-3200
I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9489 3744 Fax: (02) 9439 7439 International: +61 2 9439 3744 +61 2 9439 7439 Email:
Product Information Sheet UH36 Hi Pot Tester
Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: [email protected] Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de
Original instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
Speed sensor MiniCoder GEL 247
Speed sensor MiniCoder GEL 47 Flange assembly Technical information version 08.0 The MiniCoder family from Lenord + Bauer offers spacesaving solutions for the contactless measurement of rotational movements
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common
Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04
Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL PROFINET with IO Controller CPU 315F-2 PN/DP and IO Device ET 200S T I A Training Document Page 1 of
Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.
The perfect solution for basic servo applications Brochure May 2011 SINAMICS Answers for industry. with 1FL5 servomotors The solution for basic servo applications There is a requirement to automate motion
IBS IP KIS A. Data Sheet INTERBUS-S. Digital I/O Module
IBS IP KIS A Data Sheet Digital I/O Module Data Sheet Revision C Product Description The IBS KIS IP A module is a digital I/O module for the extended installation remote bus. Features - InterBuS-S protocol
Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004
Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter
NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential
Inductive Proximity Sensors
M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12
Patch management and security. updates SIMATIC. Process Control System PCS 7 Patch management and security updates. Preface 1
Patch management and security updates SIMATIC Preface 1 Patch management and security updates 2 Practical information 3 Process Control System PCS 7 Patch management and security updates Commissioning
3M Wrist Strap and Footwear Tester 740. User s Guide
3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6
IRT Eurocard. Type DAX-3206. Audio Extractor for 270 Mb/s SDI
I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9439 3744 Fax: (02) 9439 7439 International: 61 2 9439 3744 61 2 9439 7439 Email:
Preset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage