Current Transformers



Similar documents
Eaton Generator and Automatic Transfer Switch Generator Start Connection Diagrams

Installation instructions for Series NRX INCOM communications adapter module

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Current Transformer (CT) Selection Guide

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Equipment. Metering. Metering Equipment 1. Contents

Voltage Loss Formula s

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Installation Instructions for EHD, EDB, EDS, ED, EDH, EDC, FDB, FD, HFD, FDC, HFDDC Circuit Breakers and Molded Case Switches

Series 8146/5-V37 and Series 8150/5-V37

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

LOW-VOLTAGE CURRENT TRANSFORMERS

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

Applications. Remote Display Mounting Kits

Tape Wound, Split Core and Ebony Current Transformers

8146/5 Series Breaker Panelboards

INFORMATION FOR METER SERVICE PROVIDERS (MSP) FOR ARIZONA CERTIFICATION

Tape Wound, Split Core and Ebony Current Transformers

FW-X240 AUTO TRANSFORMER Installation Manual

Giving You the Power to Stand Alone

Nordson Automatic Spray Gun Support Kits

Medium Voltage Motor Control Assemblies

Current Transformers

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

Enhanced Quality with a Touch of Style

Continuous Power... Continuous Protection

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

GRX-PWM Pulse Width Modulation Interface

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

Evolve LED Area Light

Rotary Disconnect Switch Specifications

Contents. Clean Control Center Harmonic Correction Unit. Selection Dimensions Specifications. Description

LIEBERT VNSA Installation Sheet

Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire

Emergency lighting units EM powerled

Engineers Edge, LLC PDH & Professional Training

CPS Y S K CPS Y S C

PowerChain Management solutions. PowerChain Management Solutions for Data Centers

Power Meter Series 700

FIELDPOINT BUS EXTENDER CABLE

AMP Standard Terminals and Splices. RoHS. Ready

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

Low Voltage Transformers Sealed, General Purpose, Dry Type

ATC-300 Automatic Transfer Switch Controller

Low Voltage Switchboards The Best Technical Solution for Your Ship

Socket P2RF-05-S P2RF-08-S Clip & Release Lever R99-11 nameplate for MY

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

DECLARATION OF PERFORMANCE NO. HU-DOP_TN _001

Fault Characteristics in Electrical Equipment

CURRENT TRANSFORMERS FOR ELECTRONIC WATTHOUR METERS ADVANCED MATERIALS THE KEY TO PROGRESS

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

Chapter 5 FLOOR LOADING AND WEIGHTS

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

The following components are common to most cubicles; this example is an ABB HK cubicle.

CompactLogix Power Supplies Specifications

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Solar monitoring gateway quick start guide

How To Test A Power Switch On A Power Supply

Metering Devices IQ Analyzer 6400/6600 Series

Fire Pump Controllers Remote Alarm Panels

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Installation and operating instructions

Surgelogic Surge Protective Device (SPD)

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

New XUY roller sensors

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number VERIZON

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

Produced by Alan Ward

Surgelogic Surge Protection Device EMA, EBA, and HWA Series

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Z-TRAUQ INC. Tel.: (450) Fax: (450)

EBS852 (Contrac) Power Electronic Unit

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Current Transformers Ratio / Polarity / Types

Centro-Matic Automatic Lubrication Systems System Controls

Toroidal Conductivity Sensor

How To Power A Schen

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Simple Electrical Utility Cost Allocation Solutions

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

HMI display Installation Guide

How To Read A Pipe From A Sensor

Color Mark Sensor with Red or Green LED E3S-VS

FP-4000 Feeder Protection

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

RoomMatch Utility RMU105 TECHNICAL DATA SHEET. ultra-compact foreground/fill loudspeaker. Key Features. Technical Specifications

AMPSEAL* Automotive Plug Connector and Header Assembly

Installation Instructions

Power Supplies 3. SDN-P DIN Rail Series

Extend the Life of Existing Switchgear

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

Testing Accessories. Test PaddleS. Insulated Socket Wrench Jumper Strips Test Lead Kit. Test Paddle Attachment Clips Plugs Binding Posts

Radiant Temperature Sensor TY7321

Transcription:

Supersedes December 2002 General Description Eaton s low voltage current transformers are available in both solid core and split core designs. Engineered for electronic metering applications, all solid core designs and selected split core designs offer ANSI metering quality accuracy. The current transformer offering has a 5A secondary at the rated primary current. Split core CTs are specifically designed to be installed around primary conductors without disconnecting wires or breaking the circuit to be monitored. These current transformers are perfect solutions for energy management applications and are manufactured for installation ease. Application Description For new construction and retrofit applications where no current transformer exists, Eaton offers a complete selection of low voltage (up to 600V) current transformers. These current transformers can be used in commercial grade applications such as control panels and panelboards. Additionally, they can be used for most industrial metering applications in switchboards, switchgear and motor control centers. NNote: Not for use with IQ 35M or IQ MESII.

Product Selection Solid Core ANSI Metering Accuracy Primary Current Rating ANSI B0.1 Metering Class at 60 Hz (Accuracy in %) Window Size in Inches (mm) Diameter Figure Mounting Number for Bracket Dimensional Catalog Data Number Catalog Number 300 0.3 1.56 (39.6) S050-301 1 S050BRAC 400 S050-401 500 S050-501 600 S050-601 750 S050-751 800 S050-801 1000 S050-102 1200 S050-122 50 1.2 1.25 (31.8) S060-500 2 a 100 0.6 S060-101 150 0.3 S060-151 200 0.3 S060-201 400 0.3 3.25 (82.6) S080-401 3 S080BRAC 500 S080-501 600 S080-601 750 S080-751 800 S080-801 1000 S080-102 1200 S080-122 500 0.3 4.25 (108.0) S090-501 4 S090BRAC 600 S090-601 750 S090-751 800 S090-801 1000 S090-102 1200 S090-122 1500 S090-152 1600 S090-162 2000 S090-202 2500 S090-252 3000 S090-302 600 0.3 6.31 (160.3) S025-601 5 S025BRAC 750 S025-751 800 S025-801 1000 S025-102 1200 S025-122 1500 S025-152 1600 S025-162 2000 S025-202 2500 S025-252 3000 S025-302 3500 S025-352 4000 S025-402 25 0.3 Wound W190-025 6 W190BRAC 50 Primary W190-050 a No mounting bracket required. Product Selection (cont.) Split Core ANSI Metering Accuracy Primary Current Rating ANSI B0.1 Metering Class at 60 Hz (Accuracy in %) Figure Number for Dimensional Catalog Data Number 7 M000-401 Window Size in Inches (mm) 400 2.4 2.00 x 5.50 500 2.4 (50.8 x 139.7) M000-501 600 2.4 M000-601 800 1.2 M000-801 1000 1.2 M000-102 1200 0.6 M000-122 1500 0.6 M000-152 1600 0.6 M000-162 2000 0.6 M000-202 600 4.8 4.10 x 7.10 8 M050-601 750 4.8 (104.1 x 180.3) M050-751 800 2.4 M050-801 1000 2.4 M050-102 1200 1.2 M050-122 1500 1.2 M050-152 2000 0.6 M050-202 2500 0.6 M050-252 3000 0.6 M050-302 3500 0.6 M050-352 4000 0.3 M050-402 Split Core Primary Current Rating Accuracy at 60 Hz (in %) Window Size in Inches (mm) Figure Number for Dimensional Data Catalog Number 100 5.0 0.80 x 1.95 9 M030-101 150 5.0 (20.3 x 49.5) M030-151 200 4.0 M030-201 300 2.0 M030-301 400 2.0 M030-401 100 5.0 1.42 x 1.53 10 M040-101 150 4.0 (36.1 x 38.9) M040-151 200 1.5 M040-201 300 1.5 M040-301 400 1.5 M040-401 200 1.0 2.75 x 2.70 11 M060-201 300 (69.9 x 68.6) M060-301 400 M060-401 500 M060-501 600 M060-601 750 M060-751 800 M060-801 1000 M060-102 1200 M060-122 500 1.0 2.60 x 6.25 12 M080-501 600 (66.0 x 158.8) M080-601 800 M080-801 1000 M080-102 1200 M080-122 1500 M080-152 1600 M080-162 2000 M080-202 2500 M080-252 3000 M080-302 2

Technical Data TD02601002E Dimensions in Inches (mm) Figure 1. S050 Approximate Dimensions (4) Open Slots 0.22 x 0.34 (5.6 x 8.6) 2.75 (69.9) S050 Mounting bracket 2.23 (56.6) 1.67 (42.4) 1.10 (27.9) 3.53 (90.0) 3.00 (76.2) 3.70 (94.0) 1.56 Dia. (39.6) 1.88 (47.8) 0.31 (7.9) Approximate weight: 1 lb (2) Holes 0.20 (5.1) Diameter 2.25 (57.2) Figure 2. S060 Approximate Dimensions 5.25 (133.4) 4.00 (101.6) (2) Slots 0.28 x 0.50 (7.1 x 12.7) (2) 0.28 x 0.50 Slots (7.1 x 12.7) 3.10 (78.7) 2.88 (73.2) 3.62 (91.9) 0.88 (22.4) 1.25 Dia. (31.8) 1.95 (49.5) 4.00 (101.6) Approximate weight: 5.25 lbs 3

Dimensions in Inches (mm) (cont.) Figure 3. S080 Approximate Dimensions (8) Open Slots 0.47 x 0.22 (11.9 x 5.6) 5.73 (145.5) 4.85 (123.2) S080 Mounting bracket 3.81 (96.8) 2.19 (55.6) (4) Holes 0.42 (10.7) Dia. 0.55 (14.0) 1.15 (29.2) 1.09 (27.7) 2.91 (73.9) 3.25 (82.6) Dia. 5.73 (145.5) 2.84 (72.1) Approximate weight: 2.5 lbs 0.51 (13.0) 4.70 (119.4) Figure 4. S090 Approximate Dimensions 5.92 (150.4) 4.85 (123.2) 3.81 (96.8) S090 Mounting bracket 0 1.15 (29.2) 2.91 2.19 (73.9) (55.6) (8) Open Slots 0.47 x 0.22 (11.9 x 5.6) 3.50 (88.9) 6.17 (156.7) 4.25 (108.0) Dia. 0.42 (10.7) 2.97 (75.4) 4.86 (123.4) Approximate weight: 3 lbs (4) 0.28 x 0.63 (7.1 x 16.0) Slots 4

Technical Data TD02601002E Dimensions in Inches (mm) (cont.) Figure 5. S025 Approximate Dimensions S025 Mounting bracket 2.98 (75.7) 1.28 (32.5) 4.10 (104.1) 0 0.56 (14.2) 6.37 (161.8) 8.50 (215.9) 0.75 (19.1) (4) Slots x 1.00 (11.2 x 25.4) 6.75 (171.5) 6.31 (160.3) 8.50 (215.9) 4.25 (108.0) Approximate weight: 3 lbs 0.88 (22.4) 6.75 (171.5) (4) 0.56 (14.2) Diameter Holes Figure 6. W190 Approximate Dimensions 2.75 (69.9) (4) Closed Slots 0.21 x 0.50 (5.3 x 12.7) H2 X2 4.12 (104.6) H2 3.50 (88.9) 4.50 (114.3) 0.75 (19.1) X2 2.19 (55.6) 3.25 (82.6) (4) Open Slots x 0.50 (11.2 x 12.7) 0.38 (9.7) W190 Mounting bracket 4.69 (119.1) 4.88 (124.0) 0.50 (12.7) Approximate weight: 4 lbs 3.48 (88.4) (2) Mounting Holes 0.38 (9.7) Diameter 5

Dimensions in Inches (mm) (cont.) Figure 7. M000 Approximate Dimensions Figure 8. M050 Approximate Dimensions X2 This End Removable This End Removable Approximate weight: 1.5 lbs 4.25 (108.0) 2.00 (50.8) 0.75 (19.1) This End Removable 7.75 (196.9) 5.50 (139.7) 4.10 (104.1) 7.10 (180.3) 10.00 (254.0) 10.90 (276.9) X2 3.50 (88.9) (2) 0.19 (4.8) Diameter Holes 0.38 (9.7) 1.13 (28.7) This End Removable 6.40 (162.6) 7.30 (185.4) 1.63 (41.4) (4) 0.31 (7.9) Dia. Holes Figure 9. M030 Approximate Dimensions 6

Technical Data TD02601002E Dimensions in Inches (mm) (cont.) Figure 10. M040 Approximate Dimensions 2.50 (63.5) X2 Terminal Arrangement for 3.38 (85.9) 1.20 (30.5) X2 3.52 (89.4) 4.78 (121.4) 1.53 (38.9) 4.12 (104.6) Ratios 100:5 through 200:5 1.42 (36.1) Figure 11. M060 Approximate Dimensions Figure 12. M080 Approximate Dimensions 2.70 (68.6) 6.25 (158.8) 5.80 (147.3) - WHITE X2 - BLACK 9.25 (235.0) - WHITE X2 - BLACK 2.75 (69.9) 6.05 (153.7) 1.75 (44.5) 2.60 (66.0) 6.05 (153.7) 1.75 (44.5) 7

Eaton Corporation Electrical Sector 1000 Cherrington Parkway Moon Township, PA 15108 United States 877-ETN-CARE (877-386-2273) Eaton.com/meters 2012 Eaton Corporation All Rights Reserved Printed in USA Publication No. TD02601002E / TN March 2012 Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.