1 LOWVOLTAGE CURRENT TRANSFORMERS 5 A Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra
2 CONTENTS General specification of lowvoltage current transformers...3 LCTM wound primary series...5 LCTR round conductor series A LCTB 45 busbar series...8 LCTB 50 busbar series...9 LCTB 6 busbar series... LCTB 74 busbar series...3 LCTB 86 busbar series...5 LCTB 00 busbar series...6 LCTB 04 busbar series...7 LCTB 40 busbar series...8 LCTB 5 busbar series...0 LCTS and 3phase split core... P4 and P43 Accessories.... Digital meter N30P type Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra
3 LOWVOLTAGE CURRENT TRANSFORMERS Current transformer is used for measurement of electric alternating currents. When current in a circuit (primary current) is too high to directly apply to measuring instruments, a current transformer produces a reduced current (secondary current) accurately proportional to the current in the circuit, which can be conveniently connected to measuring and recording instruments. A current transformer also isolates the measuring instruments from what may be very high voltage in the monitored circuit. Relationship between primary and secondary currents is called rated transformation ratio. I = I. N N where: I primary current, I secondary current, N number of turns of primary winding, N number of turns of secondary winding, N/N rated transformation ratio Current transformers are used mainly in such a way that the cable from the measured shock or bus current passes through the main hole transformer, which is equivalent to one coil primary winding. In this case, the above equation simplifies to: I = I. N The task is to reduce the transformer output current for currents of over 0% of measurement range, to protect against destruction of measuring devices connected to the transformer in case of surges or failures in the primary circuit. FEATURES : Class FEATURES: Wide range of accuracy classes: S,,, Wide range of supported primary currents, the dimensions of rails, the length of casing and hole diameters. Multiple mounting methods, including wall mounting, DIN rail 35mm, the conductor, a current bar. Shields designed to seal connections. GENERAL SPECIFICATION Applicable standard: Case: IEC/EN 60044, BS 3938, IS 705 0% glass filled polycarbonate, flame retardant grades classified UL 94V0 Connection: Two connection on each side. M4 screws with self lifting clamp strap. Insulation class E (0 C max) System voltage: 70 V maximum Operating frequency: 50 Hz Rated primary rating: A 7 Rated secondary output: 5 A or A Rated burden:,.5,.5,.5, 3.75, 5, 7.5, 0,.5, 5, 0, 30, 45, 60, 00 VA :, S for laboratory and power measurement for accurate measuring for general measurement, for analog meters Ambient temperature: 0 C +45 C Storage temperature: 50 C +80 C Thermal short circuit current (Ith): 40 x In for wound type 60 x In for bus bar type Dynamic short circuit current (Idyn):.5xIth Instrument security factor (FS):.5, 5, 0 Power network meters ND0 and ND type. N4Z and N5Z DEMAND FOR POWER MEASURING DEVICES: CT users expect these devices fulfill two basic conditions: a high degree of accuracy in the nominal current, security functions with overloads. In order to fulfill these stipulations it is necessary for the power of a current transformer offered to fully achieve the actual power requirements of the measurement setup. In ascertaining the actual power requirements, consideration is to be made not only of the loss of power of the appliances to be connected up, but also the losses incurred by the instrument leads. Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra 3
4 LOWVOLTAGE CURRENT TRANSFORMERS : FEATURES Class Power requirements for measuring apparatur and relays: Analog movingiron meters 0.7.5VA Rectifier current meters VA Multirange current meters VA Current recorders VA Bimmetalic ammeters VA Power meter 5.0 VA Power factor meter VA Meters VA Relays 6.0 VA Power transducers 0. Energy meters. Internal losses of copper wiring: P= Where: I Secondary nominal current, L Distance in [m], qcu wire crosssection in [mm]. I x L [VA] qcu x 56 Table for values appertaining to 5 A qcu m m 3m 4m 5m 6m 7m 8m 9m 0 m mm mm mm mm Table for values appertaining to A qcu 0 m 0 m 30 m 40 m 50 m 60 m 70 m 80 m 90 m 00 m.0 mm mm mm mm mm Factor of safety (FS) and 3phase P4 and P43. FS class and Transformer type Remarks Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra 4 Remarks Busbar series LCTB LCTM 6/W (40) LCTB 74/0 (45) LCTM 74/W (45) LCTB 74/30 (45) Range: 7 and 80A, FS 0, class: LCTB 74/40 (45) LCTR 45/4 (40) LCTB 74/50 (45) LCTR 50/4 (30) LCTB 86/40 (45) Range: 00A, 0A i, FS 0, class: LCTR 50/4 (50) LCTB 86/50 (45) Range: 0A and, FS 0, class: LCTR 6/R (40) LCTB 86/60 (45) Range: 00A, FS 0, class:, Range: 00A, FS 0, class: LCTB 00/00V (45) Range: 400A, 500A, 600A i 750A, FS 0, class: Range: 00A,0A and, FS 0, class: Busbar series LCTB FS class and Wound primary series LCTM Round conductor series LCTR Digital meter N30P type LCTB 45/ (40) LCTB 00/30V (45) Range: 400A, 500A and 600A, FS 0, class: LCTB 50/ (30) LCTB 04/60 (45) Range: 50A and 00A, FS 0, class:, Range: 00A, 0A and, FS 0, class: LCTB 50/30 (30) LCTB 04/80 (45) Range: 50A and 300A, FS 0, class: LCTB 50/ (50) LCTB 40/80 (45) LCTB 50/30 (50) LCTB 40/00H (45) Range: 00A and 50A, FS 0, class: LCTB 6/0 (40) LCTB 40/00V (45) Range: 00A, 50A and 300A, FS 0, class: LCTB 6/30 (40) LCTB 40/30V (45) Range: 4000A and 5000A, FS 0, class: and LCTB 6/40 (40) LCTB 5/5 (50) LCTB 6/30 (50) LCTB 5/67 (50) Range 000A, 6000A and 7500A, FS 0, class:
5 WOUND PRIMARY SERIES LCTM LCTM 6/W (40) LCTM 74/W (45) Depth 6 mm 74 mm Width 40 mm Primary winding A...5 A A...60 A Secondary winding A, 5 A A, 5 A ; ; ; ; LCTM 74/W (45) LCTM 6/W (40) LCTM 6/W (40) : LCTM 74/W (45) Rated primary current A...5 A A.. 0 A.. 5 A.. 0 A.. 5 A.. 30 A. 40 A. 50 A. 60 A. ORDER You must give: transformer type / primary current / secondary current / power / accuracy class Order example: LCTM 6/W (40) 5/, 5VA, cl. Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra 5
6 LCTR ROUND CONDUCTOR SERIES LCT R 45/4 (40) LCT R 50/4 (30) Ø 4 mm Ø 4 mm Ø 4 mm Ø mm Width 40 mm 3 mm 5 mm 40 mm Depth 50 mm 50 mm 6 mm 30 A A A A... A, 5 A A, 5 A A, 5 A A, 5 A ; ; ; ; ; Hole diameter Primary winding Secondary winding Accuracy class LCTR50/4(50) LCTR6/R(40) LCTR 50/4 (30) LCTR 45/4 (40) and 3phase P4 and P43. LCTR 45/4 (40) Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra 6 Rated primary current Digital meter N30P type LCTR 50/4 (30) 30 A 40 A 50 A.. 60 A.. 75 A.. 80 A.. 00 A A A A A A VA
7 ROUND CONDUCTOR SERIES LCTR LCTR 50/4 (50) LCTR 6/R LCTR 50/4 (50) LCTR 6/R Rated primary current 30 A 40 A 50 A A A A A A A A A A.. 7. ORDER You must give: transformer type / primary current / secondary current / power / accuracy class Order example: LCTR 50/4 (50) 00/, 5VA, cl. ACCESSORIES: DIN rail mounting base order code: Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra 7
8 LCTB 45 BUSBAR SERIES LCTB 45/ (40) Hole diameter Busbar 0 x 0 mm Depth 40 mm Width Primary winding Secondary winding Ø 0 mm 50 A... A, 5 A ; LCTB 45/0 (40) and 3phase P4 and P43. Rated primary current Digital meter N30P type Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra 8 LCTB 45/0 (40) 50 A. 60 A. 75 A. 80 A. 00 A A A A. 00 A A 3.7 ORDER You must give: transformer type / primary current / secondary current / power / accuracy class Order example: LCTB 45/ (40) 00/, 3.75VA, cl. ACCESSORIES: DIN rail mounting base order code:
9 BUSBAR SERIES LCTB 50 LCTB 50/ (30) LCTB 50/30 (30) LCTB 50/ (50) LCTB 50/30 (50) Ø mm Ø mm 0 x 0 mm 30x0mm,0x5mm, 0x0mm,x0x0mm 0 x 0 mm 30x0mm,0x5mm, 0x0mm,x0x0mm Depth 3 mm 3 mm 5 mm 5 mm Width 50 mm 50 mm 50 mm 50 mm 40 A A A A... Secondary winding A, 5 A A, 5 A A, 5 A A, 5 A Accuracy class ; ; ; ; Hole diameter Busbar Primary winding LCTB 50/30 (30) LCTB 50/ (30) LCTB 50/ (30) LCTB 50/30 (30) Rated primary current 40 A 50 A 60 A 75 A. 80 A.. 00 A... 0 A... 5 A A A A Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra 9
10 LCTB 50 BUSBAR SERIES LCTB50/ (50) LCTB 50/30 (50) LCTB 50/ (50) and 3phase P4 and P43. Digital meter N30P type Tel: (+48 68) ; ; ; ; ul. Słubicka 657 Zielona Góra 0 LCTB 50/30 (50) Rated primary current 50 A.. 60 A.. 75 A A.. 00 A.. 0 A A. 50 A 00 A A ORDER You must give: transformer type / primary current / secondary current / power / accuracy class Order example: LCTB 50/ (50) 00/, 5VA, cl. ACCESSORIES: DIN rail mounting base order code:
11 BUSBAR SERIES LCTB 6 LCTB 6/0(40) LCTB6/30(40) LCTB6/30(50) LCTB6/40(40) Hole diameter Ø 30 mm Ø 30 mm Ø 3 mm Busbar 0x mm, x5x6 mm 30x0 mm, x5 x0 mm 30x0 mm, x5x0 mm 40x0 mm, x30x0 mm Depth 40 mm 40 mm 50 mm 40 mm Width 6 mm 6 mm 6 mm 6 mm 50 A A A 00 A A 40 A A Secondary winding A, 5 A A, 5 A A, 5 A A, 5 A Accuracy class S; ; ; S; ; ; S; ; ; S; ; ; Primary winding LCTB 6/0 (40) LCTB 6/30 (40) LCTB 6/0 (40) LCTB 6/30 (40) S 50 A. 60 A 75 A 80 A 00 A. 0 A S VA A A VA A A A 800 A Power transformer Rated primary current Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra
12 LCTB 6 BUSBAR SERIES LCTB 6/40 (40) LCTB 6/30 (50) LCTB 6/30 (50) S Rated primary current and 3phase P4 and P43. Digital meter N30P type Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra LCTB 6/40 (40) S 40 A 50 A. 60 A. 75 A.. 80 A A.. 0 A... 5 A A VA VA A 3 VA A 3 VA... 3 VA A A 6.. ORDER You must give: transformer type / primary current / secondary current / power / accuracy class Order example: LCTB 6/40 (40) 00/, VA, cl. ACCESSORIES: DIN rail mounting base order code:
13 LCTB 74 BUSBAR SERIES LCTB74/0(45) LCTB74/30(45) LCTB74/40(45) LCTB74/50(45) Ø 0 mm Ø 6 mm Ø 35 mm Ø 4 mm 0x0 mm 30x5 mm, x0x0 mm 40x mm, x30 x5 mm 50x mm, x40x0 mm Depth Width 74 mm 74 mm 74 mm 74 mm 30 A A A 40 A A 00 A A A, 5 A A, 5 A A, 5 A A, 5 A S; ; ; S; ; ; S; ; ; Hole diameter Busbar Primary winding Secondary winding Accuracy class S; ; ; LCTB 74/0 (45) LCTB 74/30 (45) LCTB 74/0 (45) LCTB 74/30 (45) S 30 A. 40 A 50 A A 75 A A A A A A A.. 50 A A A Rated primary current S Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra 3
14 LCTB 74 BUSBAR SERIES LCTB 74/40 (45) LCTB 74/50 (45) LCTB 74/40 (45) S Rated primary current and 3phase P4 and P43. Digital meter N30P type Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra 4 LCTB 74/50 (45) S 40 A 50 A 60 A 75 A. 80 A. 00 A... 0 A... 5 A A A A A. 800 A A. ORDER You must give: transformer type / primary current / secondary current / power / accuracy class Order example: LCTB 74/50 (45) 00/,.5VA, cl. ACCESSORIES: DIN rail mounting base order code:
15 BUSBAR SERIES LCTB 86/40 (45) LCTB 86/50 (45) LCTB 86/60 (45) Ø 36 mm Ø 46 mm Ø 5 mm Busbar 40 x 0 mm, x 30 x 5 mm 50 x mm, x 40 x 5 mm 60 x mm, x 50 x 5 mm Depth 5 mm Width 86 mm 86 mm 50 mm 50 A A 00 A...50 A 50 A... A, 5 A A, 5 A A, 5 A S; ; ; S; ; ; S; ; ; Hole dimeter Primary winding Secondary winding LCTB 86 LCTB 86/50 (45) LCTB 86/40 (45) LCTB 86/60 (45) Accuracy class LCTB 86/40 (45) S LCTB 86/50 (45) S Rated primary current LCTB 86/60 (45) S 50 A. 60 A. 75 A. 80 A. 00 A A A A A A A A A. 00 A. 50 A. ORDER You must give: transformer type / primary current / secondary current / power / accuracy class ACCESSORIES: DIN rail mounting base Order example: LCTB 86/50 (45) 00/,.5VA, cl. order code: Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra 5
16 LCTB 00 BUSBAR SERIES LCTB 00/00V (45) LCTB 00/30V (45) Busbar 4 x 03 mm 38 x 8 mm Depth Width 00 mm 00 mm A, 5 A A, 5 A S; ; ; ; ; Primary current Secondary current LCTB 00/30V (45) LCTB 00/00V (45) and 3phase P4 and P43. Digital meter N30P type Tel: (+48 68) ; ; ; ; export@lumel.com.pl LCTB 00/00V (45) S Primary current LCTB 00/30V (45) A A A 00 A 50 A A A ul. Słubicka 657 Zielona Góra 6 ORDER You must give: transformer type / primary current / secondary current / power / accuracy class Order example: LCTB 00/30V (45) 400/,.5VA, cl. ACCESSORIES: DIN rail mounting base order code:
17 BUSBAR SERIES LCTB 04 LCTB 04/60 (45) LCTB 04/80 (45) Ø 54 mm Ø 65 mm Busbar 60 x mm, x 50 x 5mm, x 40 x 0 mm 80 x mm, x 60 x 5 mm, x 50 x 5 mm Depth Width 04 mm 04 mm 00 A A A A, 5 A A, 5 A S; ; ; S; ; ; Hole diameter Primary current Secondary current LCTB 04/80 (45) LCTB 04/60 (45) LCTB 04/60 (45) S Rated primary current LCTB 04/80 (45) S 00 A. 0 A. 5 A. 50 A.. 00 A. 50 A A 800 A A A 4 50 A A ORDER You must give: transformer type / primary current / secondary current / power / accuracy class Order example: LCTB 04/60 (45) 00/,.5VA, cl. ACCESSORIES: DIN rail mounting base order code: Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra 7
18 LCTB 40 BUSBAR SERIES LCTB 40/80 (45) LCTB 40/00H (45) LCTB 40/00V LCTB 40/30V (45) Ø 7 mm Ø 86 mm Ø 86 mm Busbar 80 x 30 mm, x 60 x 5 mm 00 x 30 mm, x 80 x 5 mm, x 70 x 30 mm 00 x 30 mm, x 80 x 5 mm, x 70 x 30 mm 70 x 30 mm Depth 5 mm Width 40 mm 40 mm 40 mm 40 mm 00 A A 00 A A 00 A A A A, 5 A A, 5 A A, 5 A A, 5 A S; ; ; S; ; ; S; ; ; S; ; ; Hole diameter Primary winding Secondary winding Accuracy class LCTB 40/00H (45) LCTB 40/80 (45) and 3phase P4 and P43. Digital meter N30P type Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra 8 LCTB 40/80 (45) S Rated primary current LCTB 40/00H (45) S 00 A A A A A 00 A. 50 A A A 4000 A
19 BUSBAR SERIES LCTB 40/00V (45) LCTB 40 LCTB 40/30V (45) LCTB 40/00V (45) S Rated primary current LCTB 40/30V (45) A. 50 A A A 7,. 000 A 00 A A A VA 3000 A 4000 A 5000 A ORDER You must give: transformer type / primary current / secondary current / power / accuracy class Order example: LCTB 40/00H (45) 00/, 3.75VA, cl. Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra 9
20 LCTB 5 BUSBAR SERIES LCTB 5/5 (50) LCTB 5/67 (50) Busbar 3 x 9 mm 66 x 65 mm Depth 50 mm 50 mm Width 5 mm 5 mm A 000 A...7 A, 5 A A, 5 A S; ; ; S; ; ; Primary winding Secondary winding LCTB 5/67 (50) LCTB 5/5 (50) and 3phase P4 and P43. Digital meter N30P type Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra 0 LCTB 5/5 (50) S 750 A 800 A 000 A 00 A 50 A LCTB 5/67 (50) S A A A A 00 VA 00 VA A 00 VA 00 VA Rated primary current ORDER You must give: transformer type / primary current / secondary current / power / accuracy class Order example: LCTB 5/5 (50) 600/, 0VA, cl.
21 SPLIT CORE SERIES LCTS Window dimensions LCTS 93/30SC (40) LCTS 5/50SC (40) LCTS 55/80SC (40) LCTS 95/80SC (64) 3 x 33 mm 8 x 5 mm 8 x mm 8 x 6 mm Depth 40 mm 40 mm 40 mm 64 mm Width 93 mm 5 mm 55 mm 95 mm 00 A A A 50 A A A Secondary winding A, 5 A A, 5 A A, 5 A A, 5 A Accuracy class ; ; 3 ; ; ; Primary winding LCTS 5/50SC, 55/80SC, 95/80SC LCTS 93/30SC (40) Side view Front view (dimension in mm) a b c d e 5/50SC (40) 50 55/80SC (40) /80SC (64) Front view Side view (dimension in mm) LCTS 93/30SC (40) Typ a b c d e 5/50SC (40) /80SC (40) /80SC (64) LCTS 5/50SC (40) 3 00 A A A. 50 A A 800 A 000 A 00 A 50 A LCTS 95/80SC (64) , A A A A 4 Rated primary current LCTS 55/80SC (40) ORDER You must give: transformer type / primary current / secondary current / power / accuracy class Order example: LCTS 93/30SC (40) 00/,.5VA, cl. Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra
22 ACCESSORIES Terminal Cap Terminal Thread Cutting Screw Swivel Core and 3phase P4 and P43. Shoe for Self Tapping Screw DIN Rail Plate Case Wall Mounting Clamp and 3phase P4 and P43. N4Z and N5Z Digital meter N30P type Description Thread cutting screw 8 x 35mm Thread cutting screw 8 x 45mm Thread cutting screw 8 x 75mm Wall mounting clamp Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra Swivel Shoe for self tapping M4 screw View
23 ACCESSORIES DIN Rail Mounting Base: Order code LCTR 50 (30), LCTB 50 (30) LCTR 45, LCTB LCTM 6W, LCTM 74W LCTR 6 LCTB 6 (40), LCTB 74, LCTB 86, LCTB 00, LCTB 04 View Busbar mounting kit: Kit order code Description No. of pcs Wall mounting clamp LCTR 45, LCTB 45, LCTM 6W, LCTM 74W Thread cutting screw 8 x 35mm Wall mounting clamp Swivel Shoe for self tapping M4 screw Thread cutting screw 8 x 45mm Wall mounting clamp Swivel Shoe for self tapping M4 screw Thread cutting screw 8 x 45mm 4 Wall mounting clamp Swivel 4 Shoe for self tapping M4 screw 4 Thread cutting screw 8 x 75mm 4 Wall mounting clamp Swivel 4 Shoe for self tapping M4 screw 4 Thread cutting screw 8 x 75mm Thread cutting screw 8 x 45mm 5 Wall mounting clamp Shoe for self tapping M4 screw 6 Thread cutting screw 8 x 75mm 6 Wall mounting clamp Shoe for self tapping M4 screw 6 Thread cutting screw 8 x 35mm 6 Wall mounting clamp Shoe for self tapping M4 screw LCTR 50, LCTB 50 LCTR 6, LCTB 6, LCTB 74, LCTB 86 Power network Analog meters meterseand0 type. series LCTB 04 Power network meters ND0 and ND type. LCTB 40 LCTB 40/30 V N4Z and N5Z N4Z and N5Z LCTB 5 LCTB 00/00 V, LCT 00/30 V Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra 3
24 5 A and 3phase P4 and P43. Digital meter N30P type Tel: (+48 68) ; ; ; ; export@lumel.com.pl ul. Słubicka 657 Zielona Góra 4 ul. S³ubicka, 657 Zielona Góra, POLAND Export department: (+48 68) ; ; ; ; fax: export@lumel.com.pl ver.6/ may 03
Vario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationCurrent transformers (CT) & Shunts
Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW 9 9 9 Current summation JVM 0 9 TCR usbar
More informationTape Wound, Split Core and Ebony Current Transformers
Tape Wound, Split Core and Ebony Current Transformers Current Transformers Contents Page Tape Wound Measuring and Protection Current Transformers 2 6 Split Core Current Transformers 7 9 3-in-1 Current
More informationTape Wound, Split Core and Ebony Current Transformers
Tape Wound, Split Core and Ebony Current Transformers Table of contents Tape Wound Measuring and Protection Current Transformers 2 MR Series Measuring Range 3 PR Series Protection Range 4 Class PX Current
More informationMedium-voltage transformers
Medium-voltage transformers We make energy measurable and take care of your future www.mbs-ag.com Page 2 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Contents Current transformers Technical characteristics
More informationH/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationkeep your measure under control
INSTRUMENTACIÓN INDUSTRIAL ZURC, S.A. keep your measure under control CURRENT For measuring instruments. Mounted in selfexinguishing, plastic, strengthened cases. Isolation voltage V Made as per UNEEN
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More informationZ-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com
CURRENT TRANSFORMER MODEL J " x 7" PAGE No 2-2 REV 8DEC00 TERMINAL OPTION LEAD WIRE OPTION 8-2 BRASS SCREW TERMINALS (2 PLACES) SEE NOTE 9 6 9 8 6 Ø 2 9 (4 PLACES) UL 05 #6 AWG LEAD WIRE, STANDARD LENGTH
More informationKOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB
KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB KOLMA and IHDA Indoor Type Cable Current Transformers Index Description... 3 Technical
More informationMeasurement and Instrumentation
POWER QUALITY ENERGY PERFORMANCE Measurement and Instrumentation Transformers and shunts Transformers Overview of ranges Selection guide Info & advice Standard industrial transformers TCR TCRO ranges Adaptable
More informationMeasurement devices Accessories for analogue and digital instruments
Accessories for analogue and digital instruments 1 2CSC96F0001 Current transformers Used to transform primary currents (max. 6000 A) into.../5 A and.../1 A low secondary currents indirectly supplying power
More informationCURRENT TRANSFORMERS INSTALLATION GUIDE
CURRENT TRANSFORMERS INSTALLATION GUIDE Information contained within this document is subject to change without notice and does not represent a commitment on the part of PRI Ltd or its agents. E&OE. Copyright
More informationCURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X
CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationEnhanced Quality with a Touch of Style
Rudolf Current Transformer Enhanced Quality with a Touch of Style Current Transformer Enhanced Quality with a Touch of Style New Products Rudolf launched our new encapsulated current transformer. Portraying
More informationDigital Energy ITI. Instrument Transformer Basic Technical Information and Application
g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationCurrent Transformers
Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 Current Transformers Current transformers (CT's) provide
More informationTemperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,
Accessories Temperature Sensors for Injection Molding Types 6192B, 6193B, 6194B, 6195B Temperature sensors for measuring the contact temperature directly in the cavity at the surface of the solidified
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationRISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationDRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
More informationLOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS
Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEB Standard 027: 1998 CEYLON
More informationA project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
More informationCopper and Aluminum busbars
Copper and Aluminum busbars Two metals are currently used as conductors in electric panel boards: copper and aluminum In particular, when in need to define a power distribution inside an electric panel
More informationSolid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C
Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting
More informationT7079A,B Solid State Remote Temperature Controllers
T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationCurrent transformer selection guide
The selection of a current transformer is a simple task. There are four phases in the selection procedure. Current transformer selection guide KEEP IN MIND efine customer requirements based on the primary
More informationElectro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N
More information3-Component Measuring System
Force 3-omponent Measuring System for utting Force Measurement During Turning Modular system for measurement of cutting forces when turning outside and inside diameters on turret lathes. Machine adapters
More informationRadiant Temperature Sensor TY7321
AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional
More informationAmmeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
More informationSMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
More informationH45 LED - Direct and indirect pendant
RAL 01 10 00 IP 20 230V 50/60Hz Specifications Direct and indirect light pendant linear luminaire. Aluminium profile. Diffusers in frosted polycarbonate profile. Driver included. Supplied with clear base,
More informationAmmeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
More informationADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
More information3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
More informationJ TB/TW Temperature limiter, temperature monitor
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationFeatures. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationCurrent and Energy. Measurement Technology
Current and Energy Measurement Technology Current Measurement and Evaluation WAGO s Solution for Energy Monitoring and Conservation Rogowski Coils, 855 Series Conversion of AC currents up to 500 A/2000
More informationSocket P2RF-05-S P2RF-08-S Clip & Release Lever R99-11 nameplate for MY
Screwless Clamp Terminal Socket Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double wiring
More informationPSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
More informationAZ420 MINIATURE GENERAL PURPOSE RELAY
MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 0 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available
More informationPluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationNIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES
NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity
More informationPhone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
More informationT 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationCurrent Transformers
Supersedes December 2002 General Description Eaton s low voltage current transformers are available in both solid core and split core designs. Engineered for electronic metering applications, all solid
More informationProduct data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
More informationTerminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
More informationDiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
More informationProduct and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
More informationGivare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
More information40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
More informationtype V46, solenoid or pneumatic operated
SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function
More informationIEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
More informationMeter Relays. 077 Series Analogue Meter Relays. Features. Applications
077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationSystem 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8
System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationCurrent Transformers Ratio / Polarity / Types
CT1 Current Ratio / Polarity / Types Application Current (CT s) are instrument transformers that are used to supply a reduced value of current to meters, protective relays, and other instruments. CT s
More informationLow Voltage Switchboards The Best Technical Solution for Your Ship
The Best Technical Solution for Your Ship Wärtsilä SAM Electronics Optimal Power Distribution The uninterrupted supply of power to systems and consumers onboard modern ships is an extremly important matter.
More informationVCE VET ENGINEERING STUDIES
Victorian Certificate of Education 2013 SUPERVISOR TO ATTACH PROCESSING LABEL HERE STUDENT NUMBER Letter Figures Words VCE VET ENGINEERING STUDIES Written examination Section Wednesday 20 November 2013
More informationELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
More informationDifferential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
More informationFeed-through terminal block - SSK 110 KER-EX - 0502058
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
More informationDuroSite TM High Bay Lighting
DuroSite TM High Bay Lighting LED White Lighting Brochure for Industrial Applications CE version Application: The first of its kind, the Dialight DuroSite TM LED High Bay luminaire was designed specifically
More information0.84" x 2.00" Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com SPLIT CORE CURRENT TRANSFORMER MODEL 1SP.
SPLIT CORE CURRENT MODEL 1SP 0.84" x 2.00" PAGE No 3-2 REV 18DEC00 UL 1015 LEAD WIRE, STANDARD LENGTH IS 36 E DIMENSIONS A = 0.84 MIN B = 2.00 MIN C = 3.31 MAX D = 3.09 MAX E = 0.61 MAX F = 0 MAX F C B
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationPosition Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
More informationDEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
More informationMedium voltage product. Instrument transformers for indoor applications Product overview
Medium voltage product Instrument transformers for indoor applications Product overview 02 Contents Introduction Current transformers Supporting type 6 TPU, TPE 7 KOFA, IHBF 10 Dummy Bus type 8 KOKS 12,
More informationPower Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
More informationProblem / Solution. The problem:
Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is
More information2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch
2 Wire Electronic Time Delay Switch Cat No. DS1 2 Wire Slave Switch Cat No. DSS 3 Wire Electronic Time Delay Switch Cat No. DS2 Installation & Operating Instructions DS1/DSS Instructions for Installation
More informationCircuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
More informationCalculation of the Current Transformer Accuracy Limit Factor Application Note
Calculation of the Current Transformer Application Note kansikuva_bw 1MRS 755481 Issued: 09.11.2004 Version: A/09.11.2004 Calculation of the Current Transformer Application Note Contents: 1. Scope...4
More informationNew Media Power Socket Outlets. New Media Power Socket Outlets
New Media Power Socket Outlets The New Media Modules offer a flexible build solution to a host of individual power socket outlet requirements. The clip fit grid modules are simple to install in their blank
More informationEGSTON Standard E2xFxWx 12W
General description The family of switchmode power supplies offers an unmatched degree of flexibility and performance fulfilling even the most stringent requirements. Highly flexible electrical configuration
More informationContact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationDigital display DA 48
Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital
More informationUncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection
More informationMagnetic proximity switches
Magnetic proximity switches Magnetic proximity switches Overview Page 38 Functional principle and installation Page 39 Cylindrical designs Page 41 Rectangular designs Page 42 37 Kurzübersicht Magnetoresistive
More informationHPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80
Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...
More informationApplication/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More information