Equipment. Metering. Metering Equipment 1. Contents

Size: px
Start display at page:

Download "Equipment. Metering. Metering Equipment 1. Contents"

Transcription

1 1 October 00 Utilities Servicing Texas Metering Equipment Contents Page Logic ing System Product Selection by Utility CenterPoint Energy (Reliant & HL&P) AEP WEST (Arkansas, Louisiana, Oklahoma, Texas) CoServ Utility Texas New Mexico Power Utility ONCOR (Texas Utilities TXU Area) Xcel Utility Technical Data Knockout Drawings Meter Packs Product Product Selection Main Tenant Circuit Breakers Product Product Selection Dimensions and Knockouts Accessories Meter Packs Group Metering TD00001E

2 s Logic October 00 ing System Table 1. RS Group ing System UT RS 0 B CH Standard Prefix (See Prefix Guide) See Product Group Designators Ampere Rating 1 = 100 Amperes = 00 Amperes = 10 Amperes Service Design 0 = Overhead 1 = Combination Overhead/ Underground = Underground, Side Wired 3 = Combination, Overhead/ Underground, Side Wired Maximum Conductor (Line & Load) 0 = Connectors 1 = #/0 Connectors = #0 kcmil Connectors 3 = #30 kcmil Connectors Standard Suffixes A = Solid Top B = Small Hub Opening C = Small Hub Closure Plate L = 1-1/" Hub M = 1-1/" Hub N = " Hub P = -1/" Hub T = Large Hub Opening U = Large Hub Cover Plate V = -1/" Large Hub Q = 3" Large Hub R = 3-1/" Large Hub S = " Large Hub Z = Large to Small Hub Adapter Mounted RS Group = Residential Service, Single Position. Note: Some sockets that are built for specific utilities have their own unique catalog numbers. These can be found on the utility selection pages. Prefix Guide A B F G H I M N R S T TT U Z Aluminum enclosure Barrel lock provision, for an exposed INNER-TITE or Brooks barrel lock; unit includes an internal lock receiver bracket. Barrel lock with guard provision, for a lock guard INNER-TITE or Brooks barrel lock; unit includes an internal lock receiver bracket. Grounded fifth terminal (9 o clock position) Horn bypass Inhibitor installed in wire connectors Temporary meter cover (waxed cardboard) No sealing ring (applies only to ring style sockets) Ring style socket Aluminum screw type sealing ring (applies only to ring style sockets) Grounding connector (#1 # Cu) for Tri-Plex ground Two () grounding connectors (#1 # Cu) for Quad-Plex ground UL (Underwriters Laboratories) labeled /16 Hex head connector screw in place of slotted (100 amperes only) Note: The U prefix is always used first followed by other prefixes required in alphabetical order. TD00001E

3 October 00 s Logic 3 Table. R-6R and H-6H Group ing System UT R B CH Standard Prefix (See Prefix Guide on Page ) See Product Group Designators Ampere Rating 1 = 100 Amperes = 00 Amperes Service Design 0 = Overhead 1 = Combination Overhead/ Underground = Underground, Side Wired 3 = Combination Overhead/ Underground, Side Wired = End Feed Maximum Conductor (Line & Load) 0 = Connectors 1 = #/0 Connectors = #0 kcmil Connectors 3 = #30 kcmil Connectors = #00 kcmil Connectors 6 = # kcmil Connectors 7 = #70 kcmil Connectors 8 = Dual #0 kcmil Connectors 9 = Dual #00 kcmil Connectors Standard Suffixes A = Solid Top B = Small Hub Opening C = Small Hub Closure Plate L = 1-1/" Hub M = 1-1/" Hub N = " Hub P = -1/" Hub T = Large Hub Opening U = Large Hub Cover Plate V = -1/" Large Hub Q = 3" Large Hub R = 3-1/" Large Hub S = " Large Hub Z = Large to Small Hub Adapter Mounted R-6R Group = Residential Service, Multiple Position. H-6H Group = Commercial or Residential Service, Multiple Position. Table 3. H Group ing System UT H 0 3 B CH Standard Prefix (See Prefix Guide on Page ) See Product Group Designators Jaw Quantity = Terminal = Terminal 7 = 7 Terminal Ampere Rating = 00 Amperes 3 = 30 Amperes Service Design 0 = Overhead 1 = Combination Overhead/ Underground = Underground, Side Wired 3 = Combination, Overhead/ Underground, Side Wired Maximum Conductor (Line & Load) 0 = 3/8 Stud Connectors 1 = #/0 Connectors = #0 kcmil Connectors 3 = #30 kcmil Connectors = #00 kcmil Connectors 6 = # kcmil Connectors 7 = #70 kcmil Connectors 8 = Dual #0 kcmil Connectors 9 = Dual #30 kcmil Connectors Standard Suffixes A = Solid Top B = Small Hub Opening C = Small Hub Closure Plate L = 1-1/" Hub M = 1-1/" Hub N = " Hub P = -1/" Hub T = Large Hub Opening U = Large Hub Cover Plate V = -1/" Large Hub Q = 3" Large Hub R = 3-1/" Large Hub S = " Large Hub Z = Large to Small Hub Adapter Mounted H Group = Commercial or Residential Service, Single Position (lever bypass). TD00001E

4 s Product Selection by Utility October 00 CenterPoint Energy (Reliant & HL&P) 100 Ampere Single-Position 00 Ampere Single-Position Table. CenterPoint Energy (Reliant & HL&P) Approved s Dimensions in Inches Non-lever bypass. Steel enclosure. Dimensions Connections Concentric Knockouts H W D Line Load Ampere Single-Position Residential Single-Phase UNRRS101BEUSCH UNRRS111BEUSCH UNRRS111AEUSCH 1 A, Terminal, SM Hub Open, OH, Ring Style 1 A, Terminal, SM Hub Open, OH/UG, Ring Style 1 A, Terminal, Solid Top, UG, Ring Style 00 Ampere Single-Position Residential Single-Phase UNRRS0BEUSCH UNRRS13AEUSCH UNRRS13BEUSCH UNRRS13CEUSCH 00 Ampere Commercial Residential 00 A, Terminal, SM Hub Open, OH, Ring Style 00 A, Terminal, Solid Top, UG, Ring Style 00 A, Terminal, SM Hub Open, OH/UG, Ring Style 00 A, Terminal, SM Hub Cover Plate, OH/UG, Ring Style #8 /0 #8 /0 #8 /0 #8 /0 #8 /0 #8 / CH 00 A, 7 Terminal, Hub Cover Plate, Ring Style 1.06 #6 0 kcmil #6 0 kcmil Ampere Residential/Commercial K Base Sockets CH803K7 CH83K 80/ A, 7 Terminal, 3-Phase, OH/UG, LG Hub Cover Plate A, Terminal, 1-Phase, OH/UG, LG Hub Cover Plate / 0 Stud 1/ 0 Stud 1/ 0 Stud 1/ 0 Stud Table. Accessories ARP00003CH1 ARP0000CH1 ARP0000CH1 ARP00006CH ARP00007CH ARP00017CH ARP00018CH ARP00019CH3 ARP0001CH ARP0000CHB 1.00-Inch Hub 1.-Inch Hub 1-Inch Hub.00-Inch Hub Small Opening -Inch Hub Small Opening.00-Inch Hub Large Opening -Inch Hub Large Opening -Inch Hub Large Opening -Inch Hub Large Opening Small Hub Closure Plate ARP00008CH ARP00016CHB ARP0001CHAP ARP0003CHJ ARP00039CH ARP0008CH ARP003CH ARP0019CH ARP007CH ARP00119CH Small Hub Closure Plate Aluminum Large Hub Closure Plate Hub Adapter Plate Large to Small Replacement Plug-in Fifth Terminal (R and RS Models Only) Replacement Block Assembly for 100 A Sockets /0 Maximum Replacement Block Assembly for 00 A Sockets 30 Maximum Replacement Block Assembly for 10 A Sockets 0 Maximum # kcmil Lug Dual Lug Lug TD00001E

5 October 00 s Product Selection by Utility AEP WEST (Arkansas, Louisiana, Oklahoma, Texas) 00 Ampere Single-Position 00 Ampere Lever Bypass 00 Ampere Multi-Position Table 6. AEP WEST (Arkansas, Louisiana, Oklahoma, Texas) Approved s Dimensions in Inches Dimensions Connections Concentric Knockouts H W D Line Load Ampere Single-Position Residential UHTRS101BCH 1 A, Terminal, SM Hub Open, OH #8 /0 #8 / Ampere Single-Position Residential UHTRS0BCH UAHTRS0BFLCH UAHTRS0BSHCH UHTRS33CCH UHTRS3ACH UAHTRS3AFLCH UAHTRS3ASHCH Ground connection. Horn bypass. Aluminum enclosure. 00 A, Terminal, SM Hub Open, OH 00 A, Terminal, SM Hub Open, OH 00 A, Terminal, SM Hub Open, OH 00 A, Terminal, SM Hub Cover Plate, OH/UG 00 A, Terminal, Solid Top, UG 00 A, Terminal, Solid Top, UG 00 A, Terminal, Solid Top, UG 30 Ampere Commercial Residential w/ Lever Bypass UTH330TCH UTH336TCH UATH330TCH UATH336TCH UTH7330TCH UTH7336TCH UATH7330TCH UATH7336TCH 30 A, Terminal, LG Hub Open, OH/UG 30 A, Terminal, LG Hub Open, OH/UG 30 A, Terminal, LG Hub Open, OH/UG 30 A, Terminal, LG Hub Open, OH/UG 30 A, 7 Terminal, LG Hub Open, OH/UG 30 A, 7 Terminal, LG Hub Open, OH/UG 30 A, 7 Terminal, LG Hub Open, OH/UG 30 A, 7 Terminal, LG Hub Open, OH/UG 00 Ampere Single-Position Commercial w/ Lever Bypass UTH713B or TCH UATH713B or TCH A, 7 Terminal, SM or LG Hub Open, OH/UG 00 A, 7 Terminal, SM or LG Hub Open, OH/UG 00 Ampere Multi-Position Sockets Residential UHTR33TCH UHT3R33TCH UHTR3TCH UHTR39TTCH UHT6R39TTCH 00 A, Position, LG Hub Open, OH/UG, Center Feed 00 A, 3 Position, LG Hub Open, OH/UG, Center Feed 00 A, Position, LG Hub Open, OH/UG, Center Feed 00 A, Position, LG Hub Open, OH/UG, Center Feed 00 A, 6 Position, LG Hub Open, OH/UG, Center Feed # kcmil # kcmil # kcmil # kcmil Offset design. Lever bypass. kcmil line and load lugs. # kcmil # kcmil # kcmil # kcmil Table 7. Accessories ARP00003CH1 ARP0000CH1 ARP0000CH1 ARP00006CH ARP00007CH ARP00017CH ARP00018CH ARP00019CH3 ARP0001CH ARP0000CHB 1.00-Inch Hub 1.-Inch Hub 1-Inch Hub.00-Inch Hub Small Opening -Inch Hub Small Opening.00-Inch Hub Large Opening -Inch Hub Large Opening -Inch Hub Large Opening -Inch Hub Large Opening Small Hub Closure Plate ARP00008CH ARP00016CHB ARP0001CHAP ARP0003CHJ ARP00039CH ARP0008CH ARP003CH ARP0019CH ARP007CH ARP00119CH Small Hub Closure Plate Aluminum Large Hub Closure Plate Hub Adapter Plate Large to Small Replacement Plug-in Fifth Terminal (R and RS Models Only) Replacement Block Assembly for 100 A Sockets /0 Maximum Replacement Block Assembly for 00 A Sockets 30 Maximum Replacement Block Assembly for 10 A Sockets 0 Maximum # kcmil Lug Dual Lug Lug TD00001E

6 6 s Product Selection by Utility October 00 CoServ Utility 00 Ampere Single-Position 30 Ampere Single-Position Table 8. CoServ Utility Approved s Dimensions in Inches Ground connection. Lever bypass. Anti-inversion clip installed. Dimensions Connections Concentric Knockouts H W D Line Load Ampere Single-Position Residential UTRS13CCH 00 A, Terminal, SM Hub Cover Plate, OH/UG Ampere Commercial Residential w/ Lever Bypass 10063ACH UTH7339UCH 30 A, Terminal, LG Hub Cover Plate, OH/UG 8 30 A, 7 Terminal, LG Hub Cover Plate, OH/UG Ampere Single-Position Commercial w/ Lever Bypass UTH703NCH UTH733UCH 00 A, 7 Terminal, -Inch Hub Installed, OH 00 A, 7 Terminal, LG Hub Open, OH/UG Dual 30 kcmil Dual 30 kcmil Dual 30 kcmil Dual 30 kcmil Table 9. Accessories ARP00003CH1 ARP0000CH1 ARP0000CH1 ARP00006CH ARP00007CH ARP00017CH ARP00018CH ARP00019CH3 ARP0001CH ARP0000CHB 1.00-Inch Hub 1.-Inch Hub 1-Inch Hub.00-Inch Hub Small Opening -Inch Hub Small Opening.00-Inch Hub Large Opening -Inch Hub Large Opening -Inch Hub Large Opening -Inch Hub Large Opening Small Hub Closure Plate ARP00008CH ARP00016CHB ARP0001CHAP ARP0003CHJ ARP00039CH ARP0008CH ARP003CH ARP0019CH ARP007CH ARP00119CH Small Hub Closure Plate Aluminum Large Hub Closure Plate Hub Adapter Plate Large to Small Replacement Plug-in Fifth Terminal (R and RS Models Only) Replacement Block Assembly for 100 A Sockets /0 Maximum Replacement Block Assembly for 00 A Sockets 30 Maximum Replacement Block Assembly for 10 A Sockets 0 Maximum # kcmil Lug Dual Lug Lug TD00001E

7 October 00 s Product Selection by Utility 7 Texas New Mexico Power Utility 00 Ampere Single-Position 00 Ampere Lever Bypass 00 Ampere Single-Position Offset Table 10. Texas New Mexico Power Utility Approved s Dimensions in Inches Dimensions Connections Concentric Knockouts H W D Line Load Ampere Single-Position Residential UTRS101BCH UTRS111BCH 00 Ampere Single-Position Residential UTRS0BCH UTRS3ACH Ground connection. Lever bypass. Non-jaw release. Center phase disconnect. 1 A, Terminal, SM Hub Open, OH A, Terminal, SM Hub Open, OH/UG 1 00 A, Terminal, SM Hub Open, OH 1 00 A, Terminal, Offset Design, Solid Top, UG 1 30 Ampere Commercial Residential w/ Lever Bypass UTH300TCH UTH330TCH UTH7300TCH UTH7330TCH 30 A, Terminal, LG Hub Open, OH 30 A, Terminal, LG Hub Open, OH/UG 30 A, 7 Terminal, LG Hub Open, OH 30 A, 7 Terminal, LG Hub Open, OH/UG 00 Ampere Single-Position Commercial w/ Lever Bypass UTC13BCH UTH13BCH UTH13BNDCH UTH713B or TCH 00 A, Terminal, SM Hub Open, OH/UG 00 A, Terminal, SM Hub Open, OH/UG 00 A, Terminal, SM Hub Open, OH/UG 00 A, 7 Terminal, SM or LG Hub Open, OH/UG 10 Ampere Multi-Position Sockets Residential Single-Phase UTR3BCH UT3R3BCH UTR3BCH UTR3TCH 10 A, Position, SM Hub Open, OH/UG, End Feed 10 A, 3 Position, SM Hub Open, OH/UG, End Feed 10 A, Position, SM Hub Open, OH/UG, End Feed 10 A, Position, LG Hub Open, OH/UG, End Feed 00 Ampere Multi-Position Sockets Residential Single-Phase UTR33TCH UT3R33TCH UTR3TCH UTR39TTCH UT6R39TTCH A, Position, LG Hub Open, OH/UG, Center Feed 00 A, 3 Position, LG Hub Open, OH/UG, Center Feed 00 A, Position, LG Hub Open, OH/UG, Center Feed 00 A, Position, LG Hub Open, OH/UG, Center Feed 00 A, 6 Position, LG Hub Open, OH/UG, Center Feed #8 /0 #8 /0 #8 /0 #8 / Table 11. Accessories ARP00003CH1 ARP0000CH1 ARP0000CH1 ARP00006CH ARP00007CH ARP00017CH ARP00018CH ARP00019CH3 ARP0001CH ARP0000CHB 1.00-Inch Hub 1.-Inch Hub 1-Inch Hub.00-Inch Hub Small Opening -Inch Hub Small Opening.00-Inch Hub Large Opening -Inch Hub Large Opening -Inch Hub Large Opening -Inch Hub Large Opening Small Hub Closure Plate ARP00008CH ARP00016CHB ARP0001CHAP ARP0003CHJ ARP00039CH ARP0008CH ARP003CH ARP0019CH ARP007CH ARP00119CH Small Hub Closure Plate Aluminum Large Hub Closure Plate Hub Adapter Plate Large to Small Replacement Plug-in Fifth Terminal (R and RS Models Only) Replacement Block Assembly for 100 A Sockets /0 Maximum Replacement Block Assembly for 00 A Sockets 30 Maximum Replacement Block Assembly for 10 A Sockets 0 Maximum # kcmil Lug Dual Lug Lug TD00001E

8 8 s Product Selection by Utility October 00 ONCOR (Texas Utilities TXU Area) 00 Ampere Single-Position 00 Ampere Lever Bypass 10 Ampere Multi-Position Table 1. ONCOR (Texas Utilities TXU Area) Approved s Dimensions in Inches Ground connection. Dual 0 kcmil load lugs. Lever bypass. Center feed. Dimensions Connections Concentric Knockouts H W D Line Load Ampere Single-Position Residential UTRS0BCH 10 A, Terminal, SM Hub Open, OH Ampere Single-Position Residential UTRS13CCH UTRS138BCH 00 A, Terminal, SM Hub Cover Plate, OH/UG 00 A, Terminal, SM Hub Open, OH/UG 30 Ampere Commercial Residential w/ Lever Bypass UTH3369UCH UTH73069THLCH UTH73369THLCH 30 A, Terminal, LG Hub Cover Plate, OH/UG 30 A, 7 Terminal, LG Hub Open, OH 30 A, 7 Terminal, LG Hub Open, OH/UG 00 Ampere Single-Position Commercial w/ Lever Bypass UTH13BCH UTH13BNDCH UTH713THLCH 00 A, Terminal, SM Hub Open, OH/UG 00 A, Terminal, SM Hub Open, OH/UG 00 A, 7 Terminal, LG Hub Open, OH/UG 00 Ampere Multi-Position Sockets Residential Single-Phase UTR33TCH UT3R33TCH UTR3TCH UTR39TTCH UT6R39TTCH A, Position, LG Hub Open, OH/UG, Center Feed 00 A, 3 Position, LG Hub Open, OH/UG, Center Feed 00 A, Position, LG Hub Open, OH/UG, Center Feed 00 A, Position, LG Hub Open, OH/UG, Center Feed 00 A, 6 Position, LG Hub Open, OH/UG, Center Feed # kcmil # kcmil # kcmil Dual 0 kcmil Dual 30 kcmil Dual 30 kcmil Dual 30 kcmil Table 13. Accessories ARP00003CH1 ARP0000CH1 ARP0000CH1 ARP00006CH ARP00007CH ARP00017CH ARP00018CH ARP00019CH3 ARP0001CH ARP0000CHB 1.00-Inch Hub 1.-Inch Hub 1-Inch Hub.00-Inch Hub Small Opening -Inch Hub Small Opening.00-Inch Hub Large Opening -Inch Hub Large Opening -Inch Hub Large Opening -Inch Hub Large Opening Small Hub Closure Plate ARP00008CH ARP00016CHB ARP0001CHAP ARP0003CHJ ARP00039CH ARP0008CH ARP003CH ARP0019CH ARP007CH ARP00119CH Small Hub Closure Plate Aluminum Large Hub Closure Plate Hub Adapter Plate Large to Small Replacement Plug-in Fifth Terminal (R and RS Models Only) Replacement Block Assembly for 100 A Sockets /0 Maximum Replacement Block Assembly for 00 A Sockets 30 Maximum Replacement Block Assembly for 10 A Sockets 0 Maximum # kcmil Lug Dual Lug Lug TD00001E

9 October 00 s Product Selection by Utility 9 Xcel Utility Table 1. Xcel Utility Approved s Dimensions in Inches Dimensions Connections Concentric Knockouts H W D Line Load Ampere Single-Position Residential/Commercial w/ Lever Bypass Single-Phase UGTH03B or TCH UTH03B or TCH UGTH13B or TCH UTH13B or TCH UGTH33B or TCH UTH33B or TCH th terminal in 9 o'clock position. Lever bypass. th terminal in 6 o'clock position. Offset design. Anti-inversion clip installed. 00 A, Terminal, SM or LG Hub Open, OH 00 A, Terminal, SM or LG Hub Open, OH 00 A, Terminal, SM or LG Hub Open, OH/UG 00 A, Terminal, SM or LG Hub Open, OH/UG 00 A, Terminal, SM or LG Hub Open, OH/UG 00 A, Terminal, SM or LG Hub Open, OH/UG 00 Ampere Single-Position Residential/Commercial w/ Lever Bypass Three-Phase UTH03B or TCH UTH13B or TCH UTH33B or TCH UTH703B or TCH UTH713B or TCH UTH733B or TCH 00 A, Terminal, SM or LG Hub Open, OH 00 A, Terminal, SM or LG Hub Open, OH/UG 00 A, Terminal, SM or LG Hub Open, OH/UG 00 A, 7 Terminal, SM or LG Hub Open, OH 00 A, 7 Terminal, SM or LG Hub Open, OH/UG 00 A, 7 Terminal, SM or LG Hub Open, OH/UG 30 Ampere Commercial Residential w/ Lever Bypass CH CH CH CH CH CH 30 A, Terminal, LG Hub Open, OH/UG 30 A, Terminal, LG Hub Open, OH/UG 30 A, 7 Terminal, LG Hub Open, OH/UG 30 A, Terminal, LG Hub Open, OH/UG 30 A, Terminal, Solid Top, UG 30 A, 7 Terminal, LG Hub Open, OH/UG 00 Ampere Multi-Position Sockets Residential Single-Phase UTH33TCH UT3H33TCH UTH393TTCH UTH393TTCH UT6H393TTCH Meter Breaker Combo Units CMBX11B00BTS CMBX3B00BTS CMBXB00BTS 00 Ampere Lever Bypass A, Terminal, Position, LG Hub Open, OH/UG A, Terminal, 3 Position, LG Hub Open, OH/UG A, Terminal, Position, LG Hub Open, OH/UG 00 A, Terminal, Position, LG Hub Open, OH/UG 00 A, Terminal, 6 Position, LG Hub Open, OH/UG 00 A, Terminal, 00 A Main Breaker, OH/UG 00 A, Terminal, 00 A Main Breaker, OH/UG 00 A, Terminal, 00 A Main Breaker, OH/UG Ampere Lever Bypass Center feed. Ground connection. 1 circuit distribution section. Includes feed-through lugs. 3/ circuit distribution section. Feed Thru Lugs Feed Thru Lugs Table 1. Accessories ARP00003CH1 ARP0000CH1 ARP0000CH1 ARP00006CH ARP00007CH ARP00017CH ARP00018CH ARP00019CH3 ARP0001CH ARP0000CHB 1.00-Inch Hub 1.-Inch Hub 1-Inch Hub.00-Inch Hub Small Opening -Inch Hub Small Opening.00-Inch Hub Large Opening -Inch Hub Large Opening -Inch Hub Large Opening -Inch Hub Large Opening Small Hub Closure Plate ARP00008CH ARP00016CHB ARP0001CHAP ARP0003CHJ ARP00039CH ARP0008CH ARP003CH ARP0019CH ARP007CH ARP00119CH Small Hub Closure Plate Aluminum Large Hub Closure Plate Hub Adapter Plate Large to Small Replacement Plug-in Fifth Terminal (R and RS Models Only) Replacement Block Assembly for 100 A Sockets /0 Maximum Replacement Block Assembly for 00 A Sockets 30 Maximum Replacement Block Assembly for 10 A Sockets 0 Maximum # kcmil Lug Dual Lug Lug TD00001E

10 10 s Technical Data October 00 Knockout Drawings 1 3 UTRS101BCH 1 3 UTH13B or TCH 1 3 UTRS0BCH 1 3 UTH330TCH 1 3 UTRS3ACH UT3R111BCH UT3R33TCH Drawings not to scale. Figure 1. Knockout Drawings TD00001E

11 October 00 Product Group Metering Meter Packs Product Selection Table 16. Meter Pack ing System 1 M P 1 R C 11 Meter Pack Eaton s 1MP units are self-contained (main terminal box included) for installations requiring up to six meter socket positions in a single enclosure. Units are not gangable with any other metering device. Approved by major power companies, UL listed, suitable as service equipment and meets the service and electrical requirements of EUSERC and CECHA. Series rating up to 100 kaic. All ringless cover devices include fifth jaw as standard. Ring type devices do not include fifth jaw as standard. Order 1MMJK if needed. Bondable neutral. 10/0 Vac, single-phase, 3-wire metering device. Up to amperes maximum horizontal bus rating. Incoming lugs not included (phase A, phase B, and neutral). Indoor/outdoor construction. Provision for -pole breaker (plug-on type for 1 ampere sockets and bolt-on type for 00 ampere sockets) circuit breakers not included. Underground incoming feed. Aluminum or copper bus. 1-Phase When Ordering: 1. Determine catalog number of the basic device.. Include Lug Kit for incoming section. See Table Find quantity and catalog numbers for tenant circuit breakers. (Order one breaker per socket.) See Page 13.. Select required accessories. See Page 16. Table 17. Meter Packs Aluminum Bus Socket Ampere Rating of Meter Sockets Bus Ampere Rating Ringless Style Covers Ringless Style Covers with Horn Bypass Metering Type MP = Meter Pack of Meters, 3,, or 6 Blank = Accessory Ampere Rating 1 = 1 Amperes 0 = 00 Amperes Blank = Accessory Main Tenant Breaker Type Plug-on Type Plug-on Type BR_ BRH_ BRHH_ Bolt-on Type CC_X CHH_HX CHH_HX CHH_X Plug-on Type Plug-on Type BR_ BRH_ BRHH_ Bolt-on Type CC_X CHH_HX CHH_HX CHH_X Bus Material C = Copper Bus Blank = Aluminum Bus Security or Accessory Code R = Ring RRL = Ringless RRLB = Ringless with Horn Bypass LK = Lug Kit (Accessory) SC = Crimp Lug Landing Pad Kit (Accessory) Bus Ampere Rating = 00 Amperes = Amperes 6 = Amperes Blank = Accessory Catalog 1MP1RRL 1MP1RRLC 1MP31RRL 1MP1RRL 1MP16RRL 1MP616RRL 1MP0RRL 1MP306RRL 1MP06RRL 1MP06RRL 1MP606RRL 1MP1RRLB 1MP1RRLBC 1MP31RRLB 1MP1RRLB 1MP16RRLB 1MP616RRLB 1MP0RRLB 1MP306RRLB 1MP06RRLB 1MP06RRLB 1MP606RRLB See Table. Fifth jaw factory installed at 9 o clock position. Main lugs included. #6 300 kcmil. (Optional lugs are not available.) Bottom feed only. CECHA approved. Note: See Table 0 for Main Lug Kit Selection. See Table 1 for Wire Sizes. Semi-flush Flange Kit 1MPSFK1 1MPSFK1 1MPSFK 1MPSFK 1MPSFK3 1MPSFK3 1MPSFK 1MPSFK 1MPSFK 1MPSFK6 1MPSFK6 1MPSFK1 1MPSFK1 1MPSFK 1MPSFK 1MPSFK3 1MPSFK3 1MPSFK 1MPSFK 1MPSFK 1MPSFK6 1MPSFK6 TD00001E

12 1 Group Metering Meter Packs October 00 Table 18. Meter Packs Copper Bus Socket Ampere Rating of Meter Sockets Bus Ampere Rating Main Tenant Breaker Type Ringless Style Covers Plug-on Type BR_ BRH_ BRHH_ Bolt-on Type CC_X CHH_HX CHH_HX CHH_X Ringless Style Covers with Horn Bypass Plug-on Type BR_ BRH_ BRHH_ Bolt-on Type CC_X CHH_HX CHH_HX CHH_X Catalog See Table. Fifth jaw factory installed at 9 o clock position. CECHA approved. 1MP31RRLC 1MP1RRLC 1MP16RRLC 1MP616RRLC 1MP0RRLC 1MP306RRLC 1MP06RRLC 1MP06RRLC 1MP606RRLC 1MP31RRLBC 1MP1RRLBC 1MP16RRLBC 1MP616RRLBC 1MP0RRLBC 1MP306RRLBC 1MP06RRLBC 1MP06RRLBC 1MP606RRLBC Semi flush Flange Kit Catalog 1MPSFK 1MPSFK 1MPSFK3 1MPSFK3 1MPSFK 1MPSFK 1MPSFK 1MPSFK6 1MPSFK6 1MPSFK 1MPSFK 1MPSFK3 1MPSFK3 1MPSFK 1MPSFK 1MPSFK 1MPSFK6 1MPSFK6 Table 0. Main Lug Kit Selection Field Installed Kits for Either or Ampere Main Bus Line Lug and Wire Sizes Order Separately and Field Install (1) #6 kcmil or () /0 0 kcmil () 0 00 kcmil (3) # 300 kcmil (1) 70 kcmil Crimp lug landing pad 0 70 kcmil This lug is not UL listed. This kit comes with three pads for two lines and neutral. Each pad will accept one or two crimp lugs. Cannot be used on 1MP1R, RL and RLB EUSERC underground termination. Table 1. Wire Sizes Neutral and Ground Lugs Wire Size, Al/Cu Neutral: 1 ampere meter pack 00 ampere meter pack Equipment Ground Bar: 1 ampere meter pack 00 ampere meter pack Note: Each stack includes a neutral and ground bar. If an extra ground bar is needed, order 1MMGBK. Line Lug Kit Order Three Kits (For Two Lines and Neutral) 1MPLK1 1MPLK3 1MPLK 1MPLK 1MPSC1 #6 /0 #1/0 300 kcmil #1 # #1 /0 Catalog Optional Ground Bar #6 /0 1MMGBK Table 19. CECHA Approved Accessories Catalog Pedestal Trough Raceway for Underground Services Inch Pedestal Trough Raceway CH (36.00" H 9.00" W." D) -Inch Pedestal Trough Raceway (" H 9.00" W." D) Adapter Plates Adapter Plate for Gang Adapter Plate for 6 Gang Bottom raceway adapter plates required CH 1MP3EW1 1MP6EW1 TD00001E

13 October 00 Group Metering Main Tenant Circuit Breakers 13 Product 1MP, 1MM and 3MM Main Tenant Circuit Breakers The following breakers are to be used on 1MP, 1MM and 3MM modular metering stacks. They are 10/0 Vac field installed. BR100 CC00 Product Selection Table. 1MP, 1MM and 3MM Main Tenant Circuit Breakers of Poles Main Tenant Circuit Breaker Ampere Rating 10,000 AIC,000 AIC,000 AIC,000 AIC 100,000 AIC Plug-on type circuit breakers used with 1MP, 1MM and 3MM 1 ampere modular metering stacks BR60 BR70 BR80 BRH60 BRH70 BRH80 BRHH60 BRHH70 BRHH BR90 BR100 BR110 BR1 BRH90 BRH100 BRH110 BRH1 BRHH90 BRHH100 BRHH110 BRHH1 Bolt-on type circuit breakers used with 1MP, 1MM and 3MM 00 ampere modular metering stacks CHH060HX CHH070HX CHH080HX CHH060HX CHH070HX CHH080HX CHH060X CHH070X CHH080X CC100X CC1X CHH090HX CHH100HX CHH1HX CHH090HX CHH100HX CHH1HX CHH090X CHH100X CHH1X CC10X CC17X CC00X CHH10HX CHH17HX CHH00HX CHH10HX CHH17HX CHH00HX CHH10X CHH17X CHH00X Table 3. Main Breaker Selection Chart Maximum Ampere Rating -Pole Breaker 10 kaic kaic Load Side Lug Kit for BW Breakers BW100 BW1 BW10 BW00 BWH100 BWH1 BWH10 BWH00 MCBK When a provision for main is provided, order one of the main breakers listed in this table. All panels are dual labeled to accept Types BW and BWH Main Breakers. TD00001E

14 Group Metering Main Tenant Circuit Breakers October 00 Dimensions and Knockouts (in Inches) 1MP Meter Packs Aluminum and Copper Bus "Z" "Y" "X" "W" "Z" "Y" "X" "W" Concentric Knockouts 1/" Knockout "Z" = CL of 1/" Ring "Y" = CL of 1-1/" Ring "X" = CL of 1-1/" Ring "W" = CL of " Ring Concentric Knockouts 1", 1-1/", 1-1/", Knockout Concentric Knockouts -1/", 3", 3-1/", " Knockout Concentric Knockouts 1", 1-1/", 1-1/", Knockout Concentric Knockouts 1/" Knockout.69 Concentric Knockouts -1/", 3", 3-1/", " Knockout To C L of Wall Mtg. Screw Meter To CL Rail Mtg. Screw CL 7.01 (3) Knockout for 1, 1-1/, 1-1/ Conduit (1) Knockout for 1-1/,, -1/ Conduit , Meter Device 3.10, 6 Meter Device Mtn. for, -1/, 3" C-H Conduit Hubs Mtg Holes Places 1, 1-1/, 1-1/" KO 6 Places /,, -1/, 3" KO Ampere Meter Packs Figure. 1 Ampere Maximum Tenant Breaker TD00001E

15 October 00 Group Metering Meter Packs Concentric Knockouts 1/" Knockout Concentric Knockouts 1", 1-1/", 1-1/", " Knockout "Z" "Y" "X" "W" Concentric Knockouts -1/", 3", 3-1/", " Knockout Typ & 6 Meter Endwall & Meter Endwall "Z" "Y" "X" "W". 0 Concentric Knockouts -1/", 3", 3-1/", " Knockout Concentric Knockouts 1", 1-1/", 1-1/", " Knockout Concentric Knockouts 1/" Knockout "Z" = CL of 1/" Ring "Y" = CL of 1-1/" Ring "X" = CL of 1-1/" Ring "W" = CL of " Ring To C L of Wall Mtg. Screw Meter To CL Rail Mtg. Screw CL () Knock Out For 1, 1-1/, 1-1/ Conduit 3, Meter Device , 6 Meter Device 00 Ampere Meter Packs Meter Device Figure Ampere Maximum Tenant Breaker TD00001E

16 16 Group Metering Accessories Meter Packs Table. Accessories for 1MP, 1MM and 3MM Modular Metering Stacks Application Catalog Fifth Jaw Kit Bolted onto neutral in the 3, 6 or 9 o clock position. Typically used on network metering systems (3-phase in/single-phase out) or when specified by utility company. 1MMJK Isolated Fifth Jaw Kit Connects to the neutral with an insolated wire. 1MMJKOP Horn Bypass Used only on ringless cover stacks, kits can be installed on 1 ampere or 00 ampere sockets. Note: For 1MP1RRL use: 1MMBPH WCG8HB Meter Bypass Jumper Installed on 1 ampere or 00 ampere sockets. Jumpers are plugged into jaws. Order Lexan cover plate with bypass jumpers to prevent access to meter socket once energized. (Not UL listed.) 1MMBPJ Lexan Blank Cover Blank Cover Wall Mounting Rail Bussed Spacer Bus Duct Riser/ Meter Center Connection Circular cover mounted on ring or ringless devices preventing access to meter socket while meter is not in place. Includes plastic tabs which plug into each jaw. Same as 1MMPCP minus the tabs located in the back to plug into jaws. This device to be used while meter bypass jumpers are in place (1MMBPJ). Used for 1 ampere stacks. Fits bottom socket only. Kit replaces existing meter cover preventing access to meter socket. Includes hasp for seal. Used on 00 ampere stacks. Fits bottom socket only. Kit replaces existing meter cover preventing access to meter socket. Includes hasp for seal. Rails are feet (1. m) in length. Bolted on wall for stacks, packs, and mains to be hung. Bussed spacer 100 ampere -inch (101.6 mm). Required when stacks are mounted on right-hand side in EUSERC areas. (Copper) Available in,, 800 ampere Main Fusible units only. Contact Product Line for details. 1MMPCP 1MMACP 1MMBC1B 1MMBC00B 1MMWB 3MMBSK October 00 Fifth Jaw Kit Horn Bypass Kit Lexan Blank Cover Wall Mounting Rail is a federally registered trademark of Eaton Corporation. INNER-TITE is a registered trademark of Inner-Tite Corp. Lexan is a registered trademark of General Electric Co., USA. UL is a federally registered trademark of Underwriters Laboratories Inc. Bussed Spacer Eaton Electrical Inc Cherrington Parkway Moon Township, PA United States tel: Eaton Corporation All Rights Reserved Printed in USA Publication No. TD00001E / Z89 October 00

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp SERVICE ENTRANCE - UNDERGROUND 07-01-15 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS

More information

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS Prepared by: ABB1 ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS 052521 Asset Type: Electric Metering Function: Construction Issued by: Quoc Hoang (QxH1) Date: 07-01-16 Rev. #06: This document

More information

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D 12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section

More information

Section 10 Electric Switchboards: 0 Through 600 Volts

Section 10 Electric Switchboards: 0 Through 600 Volts Section 10 Electric Switchboards: 0 Through 600 Volts 10.1. Scope This section provides specific dimensions and details for service and meter equipment that is assembled by the manufacturer in freestanding,

More information

Temporary Power Outlet Panels. Selection and Application Guide. www.talonmetering.com

Temporary Power Outlet Panels. Selection and Application Guide. www.talonmetering.com Temporary Power Outlet Panels Selection and Application Guide www.talonmetering.com 2012 Siemens Industry, Inc. www.talonmetering.com Talon meter mounting equipment For more than half a century, Talon

More information

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case

More information

Temporary Power Outlet Panels

Temporary Power Outlet Panels Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order

More information

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications Product Description Product Description The Mini Power-Zone Unit Substation from Schneider Electric is a miniaturized version of our Power-Zone Unit Substation. Included are: Circuit Breaker Sealed Step-Down

More information

IRRIGATION PUMPING Table of Contents - Section 900

IRRIGATION PUMPING Table of Contents - Section 900 IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS

More information

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W Centers Combination Catalog Number Logic Combination Sockets MC 30 40 B 1 00 S E C W ere (max. circuits) (max. 1" breakers) MM = MC = Load Center Combination 1 = 1-Phase 3 = 3-Phase ML or L = Lug MB or

More information

Current Transformers

Current Transformers Supersedes December 2002 General Description Eaton s low voltage current transformers are available in both solid core and split core designs. Engineered for electronic metering applications, all solid

More information

Mini Power-Zone Unit Substation

Mini Power-Zone Unit Substation Catalog 7440CT0901 2009 Class 7440 CONTENTS Description............................................. Page Product Description...........................................2 General Information...........................................3

More information

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W. [previous page #: 2-18; 2-22]

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W. [previous page #: 2-18; 2-22] [previous page #: 2-18; 2-22] Combination Logic Combination Sockets MC 30 40 B 1 200 S E C W 2 ere (max. circuits) (max. 1" breakers) MM = MC = Load Center Combination 1 = 1-Phase 3 = 3-Phase ML or L =

More information

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents SPEEDFAX TM 20 Load Centers & Circuit Breakers Contents Load Centers ing System -2 Siemens PL and ES Series Load Centers Introduction -3 PL Series Load Centers Features and Product Offering -4-5 PL Series

More information

Power Outlet Panels. Product Guide

Power Outlet Panels. Product Guide Product Guide Construction and Recreational Vehicle (RV) Power Outlet Panels Vehicle Power (RV) Power Outlet Panels Power Outlet Panels Construction and RV Power Outlet Panels Product Description...1 Application

More information

MOBILE HOME SERVICE REQUIREMENTS GAS

MOBILE HOME SERVICE REQUIREMENTS GAS ELECTRIC AND GAS 1.0 INDEX 1.0 INDEX 2.0 PURPOSE 3.0 GENERAL 4.0 REFERENCE MATERIAL 5.0 TYPICAL UNDERGROUND UTILITY LAYOUT 6.0 METER PAD DETAILS 7.0 GENERAL INSTALLATION PROCEDURES 8.0 PEDESTAL SPECIFICATIONS

More information

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC ELECTRICAL SERVICE REQUIREMENTS ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC TABLE OF CONTENTS TITLE SECTION NO. List of Approved Electric Utility Service Equipment Requirements Committee

More information

Electrical Service Guidelines

Electrical Service Guidelines Electrical Service Guidelines Middle Tennessee Electric Membership Corporation Revised: May 23, 2013 MTEMC's Electrical Guidelines TABLE OF CONTENTS Right-of-Way Clearance Guide 3 MTEMC Requirements 4

More information

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures Meter Boxes SMB s To house a single phase kilowatt hour meter Standard kwh meter mounting Square or triangular securing screw Stand off for circuit breaker Optional circuit breaker reset rod DMB s To house

More information

Step 1: Application Instructions

Step 1: Application Instructions Step 1: Application Instructions CONTENTS Introduction Customer and Electrician Instructions Completing Section 1 or Section 2 Definitions INTRODUCTION Every effort has been made to provide clear instruction

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

CDGRD-10. Grounding. Solutions For Comm/Data Applications

CDGRD-10. Grounding. Solutions For Comm/Data Applications CDGRD-10 Grounding Solutions For Comm/Data Applications Overview & Table of Contents Cooper B-Line s Grounding products for rack & runway provide a complete solution for grounding metal supports. The offering

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

Section 5 Meters and Service Entrance Equipment

Section 5 Meters and Service Entrance Equipment Table of Contents Section 5 Meters and Service Entrance Equipment A. GENERAL... 5-3 B. METER TOTALIZING... 5-4 C. SEQUENCE OF SERVICE ENTRANCE EQUIPMENT... 5-4 D. METER LOCATIONS... 5-11 E. METER ROOMS...

More information

Please check with your local inspection authority for any additional requirements before installation.

Please check with your local inspection authority for any additional requirements before installation. Specifications for Residential Overhead Electric Service Installation This brochure addresses most typical residential overhead service installations. Variances for the following specifications must be

More information

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Learning Module 13: Panelboards and Switchboards. 101 Basic Series Learning Module 13: Panelboards and Switchboards 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Definitions 4 Similarities Between Panelboards and

More information

Approved Meter Sockets and Cabinets

Approved Meter Sockets and Cabinets Single Unit Residential Guide 1 PHASE, 120/240 VOLT S METERING (Metering sockets and cabinets are supplied by Customer). Outdoor meter mounting height is 1730 mm ( 5 8 ) to center of meter ± 100 mm ( 4

More information

TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE

TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE A. GENERAL NOTES: Service entrance line and load conductors, conduit straps, weatherhead, lock nuts, bushings, connectors, and

More information

Description. Lugs for NEMA Stud Kits a. (2) #6-350 kcmil SUK350TA (1) #2-600 kcmil SUK600TA. (2) #500-1000 kcmil SUK1000TA.

Description. Lugs for NEMA Stud Kits a. (2) #6-350 kcmil SUK350TA (1) #2-600 kcmil SUK600TA. (2) #500-1000 kcmil SUK1000TA. Uni-PAK : Accessories Selection 2 METER ECHS125 NSK400 SUK350TA Old PAK Accessories Accessories for All-In-One Units Description Catalog Number Description Catalog Number 5th Jaw Kit a Lugs for NEMA Stud

More information

Distribution Boards & Consumer Units

Distribution Boards & Consumer Units Distribution Boards & Consumer Units Enclosures for system pro M compact Distribution Boards & Consumer Units Contents General 2/ Distribution Boards Mini Center compact Mounting kits for compact accessories

More information

Multiple Meter Installation - 200 Amperes Per Position -Single Phase, Self-contained

Multiple Meter Installation - 200 Amperes Per Position -Single Phase, Self-contained Overhead Meters TABLE OF CONTENTS D D Consumer Service Pole for Mobile Home Park Temporary Service -wire Single Phase D. Overhead Meter Installation - Single Phase D. Connection Diagram - Single Phase

More information

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun DC disconnects for solar photovoltaic installations Connecting the power of the sun Solar energy is heating up Interest in renewable energy sources has never been greater, and the fastest growing of these

More information

Installation Instructions

Installation Instructions Installation Instructions S50-310 (Semi-Circular) S50-311 (Circular) Accu-Zone Infrared Control Conversion Kit for Terrazzo & Stainless Steel Classic Washfountains (Non-sectional) Table of Contents Pre-Installation

More information

Electrical Code Regulation

Electrical Code Regulation Electrical Code Regulation St. Clair County has adopted the 2005 National Electrical Code in its entirety for the unincorporated areas of the county and all communities that have contracted with the county

More information

Cable/Conduit Conversion

Cable/Conduit Conversion Cable/Conduit Conversion Busway can be used in many applications where cable and conduit are more commonly used. The question arises, Why use busway instead of conventional cable and conduit? Benefits

More information

Miniature Circuit Breakers and Supplementary Protectors

Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors. Industrial Circuit Breakers QUICKLAG............................................. QUICKLAG

More information

www.usa.siemens.com/retail Retail Reference Guide Answers for infrastructure.

www.usa.siemens.com/retail Retail Reference Guide Answers for infrastructure. www.usa.siemens.com/retail Retail Reference Guide Answers for infrastructure. Arc Fault Circuit Interrupters (AFCI) www.usa.siemens.com/afci Definition of product: Arc fault circuit interrupter (AFCI)

More information

Electronic Watt-Hour Meters Catalog

Electronic Watt-Hour Meters Catalog Catalog 1 smartbrandusa.com Ver. 15.1 Table of Contents... 3 Single Phase... 3 Two Phase... 4 Polyphase... 5... 6 Single Phase... 6 Two Phase... 7 Polyphase... 8 Accessories... 9 Meter Enclosures... 9

More information

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope 3. TYPES OF SERVICE AVAILABLE 3.1 Scope UI supplies 60 hertz, alternating current with different voltage and ampere ratings. Not all voltage and ampere ratings are available throughout the entire service

More information

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &

More information

Contractors Guide Central Inverter System Installation

Contractors Guide Central Inverter System Installation Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.

More information

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations Solar energy is heating up Interest in renewable energy sources has

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

No Phone Line II-48 System

No Phone Line II-48 System Used in conjunction with an EntraGuard Telephone Entry System, the -48 provides No Phone Line communication and door or gate control through existing building telephone lines without the need to purchase

More information

METERING INSTALLATION REQUIREMENTS

METERING INSTALLATION REQUIREMENTS METERING INSTALLATION REQUIREMENTS Table of Contents Section 300 PARAGRAPH 300.0 METERING AND SERVICE ENTRANCE EQUIPMENT... 1 300.1 GENERAL... 1 300.2 METERED AND UNMETERED CONDUCTORS... 1 300.3 SEALING

More information

Applying For New or Revised Electric Service

Applying For New or Revised Electric Service Applying For New or Revised Electric Service Dear Customer: ComEd is happy to assist you in initiating new or revised electric service to your location. Please complete, sign and return the attached service

More information

2012 Edition Redbook 11.0 GENERAL DRAWINGS AND STANDARDS

2012 Edition Redbook 11.0 GENERAL DRAWINGS AND STANDARDS 2012 Edition Redbook 11.0 GENERAL DRAWINGS AND STANDARDS Minimum Vertical Clearances Above Ground and Roofs D1 Minimum Pool Clearances D2 Minimum Clearances of Wires Adjacent to Buildings and Other Structures

More information

Parallel Redundant Uninterruptible Power Supply

Parallel Redundant Uninterruptible Power Supply 9 315 Parallel Redundant Uninterruptible Power Supply Installation/Operation Manual 164202013 Rev. D ------------------------------------------------------------------------ ------------------------------------------------------------------------

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2

More information

INFORMATION AND GUIDANCE FOR CUSTOMER ELECTRIC SERVICE

INFORMATION AND GUIDANCE FOR CUSTOMER ELECTRIC SERVICE INFORMATION AND GUIDANCE FOR CUSTOMER ELECTRIC SERVICE November 2009 November 2009 (PAGE INTENTIONALLY BLANK) CONTENTS INTRODUCTION... 1 DEFINITIONS... 2 GENERAL INFORMATION... 4 Availability & Character

More information

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE Toll Free Telephone Numbers Residential Services 800.454.3853 Commercial Services 800.653.5307 Utility Locating Company N.C. 800.632.4949 S.C. 888.721.7877

More information

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings *** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not

More information

B. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems.

B. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems. SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes wall switches; wall dimmers; receptacles; multioutlet assembly; and device plates and decorative box covers. B. Related

More information

Electric Service Requirements & Guidelines

Electric Service Requirements & Guidelines Electric Service Requirements & Guidelines Montana Service Area September 2011 NORTHWESTERN ENERGY Montana Service Area ELECTRIC SERVICE REQUIREMENTS AND GUIDELINES CONTENTS I. GENERAL INFORMATION 1.01

More information

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to: PREFACE UL developed the Dead-Front Switchboard Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in understanding deadfront

More information

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions Heat-Tracing Remote Monitoring Module for the NGC Control System Installation Instructions Tools Required 3 mm slotted screwdriver 3/8 hex key (for -4X only) Approvals Nonhazardous locations Type NM LISTED

More information

Type 1, 3, & 3R Enclosures

Type 1, 3, & 3R Enclosures Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................

More information

Co-location Interconnect Power Panel (CIPP) Installation Guide

Co-location Interconnect Power Panel (CIPP) Installation Guide Co-location Interconnect Power Panel (CIPP) Installation Guide Document INS-97xxxxxxx This guide covers the following part numbers- Trimm 97xxxxxxx Series Table of Contents Section 1 - General Information...

More information

5.2. Overview. The better method to install solderless compression connectors on power cable

5.2. Overview. The better method to install solderless compression connectors on power cable 5.2 Overview The better method to install solderless compression connectors on power cable The Thomas & Betts method of installing compression connectors on power cables is designed to provide a high degree

More information

Distribution Dry Type Transformers

Distribution Dry Type Transformers 8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg

More information

picomax The Pluggable Connection System

picomax The Pluggable Connection System picomax The Pluggable Connection System TECHNOLOGY THIS SPECIALIZED CAN T MEET ALL REQUIREMENTS. YES IT CAN. CONTENTS picomax Pin spacing: 3. mm/0.138 in;.0 mm/0.197 in; 7. mm/0.29 in Versatile Pluggable

More information

Electric Service Standards

Electric Service Standards IV: 1 of 24 IV. SERVICE and METER CONNECTIONS A. Service Equipment 1. General The Customer should consult FPL at an early stage to verify availability of service (section II.C) and to determine the FPL

More information

E2 Series Electric Furnaces

E2 Series Electric Furnaces E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...

More information

Cabinets 101: Configuring A Network Or Server Cabinet

Cabinets 101: Configuring A Network Or Server Cabinet Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What

More information

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions Self-Retracts 30 ft. Charge Cable Length Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions Safe, Convenient & Clean EV Charging The EVoReel cable management solutions

More information

UNDERGROUND ELECTRIC TEMPORARY SERVICE PANEL

UNDERGROUND ELECTRIC TEMPORARY SERVICE PANEL S 1.0 INDEX 1.0 INDEX 2.0 PURPOSE 3.0 CUSTOMER RESPONSIBILITY FOR TOTAL TEMPORARY SERVICE 4.0 CUSTOMER RESPONSIBILITY FOR TEMPORARY SERVICE IN PERMANENT LOCATION 5.0 NVE RESPONSIBILITIES 6.0 GROUNDING

More information

Type NT and Type ZWM Terminal Blocks

Type NT and Type ZWM Terminal Blocks Type NT and Type ZWM Terminal Blocks Side view of closed Sliding Link Block Sliding Link Block with white marker strip Unit-pole construction Sliding link to permit testing without disturbing wiring High

More information

PERMIT APPLICATION REQUIREMENTS FOR RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEMS

PERMIT APPLICATION REQUIREMENTS FOR RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEMS Butte County Department of Development Services PERMIT CENTER 7 County Center Drive, Oroville, CA 95965 Main Phone (530)538-7601 Permit Center Phone (530)538-6861 Fax (530)538-7785 FORM NO DBP-71 PERMIT

More information

WIRING & APPLIANCE INSTALLATION INDEX APR 2014 SECTION 7 GENERAL

WIRING & APPLIANCE INSTALLATION INDEX APR 2014 SECTION 7 GENERAL WIRING & APPLIANCE INSTALLATION INDEX APR 2014 SECTION 7 GENERAL Voltage Drop Factors... 7-2-13 and 7-2-14 Amperes to KVA... 7-2-15 KVA to Amperes... 7-2-16 SPACE CONDITIONING and GENERAL SERVICE Metering

More information

Installation. Smart-UPS VT and MGE Galaxy 3500. Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V

Installation. Smart-UPS VT and MGE Galaxy 3500. Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V Installation Smart-UPS VT and MGE Galaxy 3500 Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V Contents Safety... 1 SAVE THESE INSTRUCTIONS...............................

More information

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors C O M M E R C I A L N E T W O R K I N G C O P P E R 15.13 Distribution Connectors, Multiplying Connectors and Modular Jack Connectors A0393146 QCBIX1A4 Connector BIX Distribution Connector The BIX Distribution

More information

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially

More information

POLARIS INSUL-TAP CONNECTORS FOR TWO WIRES & IN-LINE SPLICERS/REDUCERS

POLARIS INSUL-TAP CONNECTORS FOR TWO WIRES & IN-LINE SPLICERS/REDUCERS INSUL-TAP CONNECTORS FOR TWO S & IN-LINE SPLICERS/REDUCERS IT SERIES 1 2 3 4 Insul-Tap connectors are suitable for connecting two wires. For sizes 3/0 AWG and smaller, they are available in two styles

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

SERVICE ENTRANCE REQUIREMENTS MANUAL

SERVICE ENTRANCE REQUIREMENTS MANUAL SERVICE ENTRANCE REQUIREMENTS MANUAL 7th Edition 2012 TABLE OF CONTENTS BTU General Policies and Procedures... 3 SECTION 1: Temporary Construction Meter Poles... 5 Temporary Overhead Fed Meter Pole...

More information

Relay mounting systems

Relay mounting systems Page 1 Issued July 1998 Changed since April 1997 Data subject to change without notice RL COMBIFLEX RE 500 (SE 94832) (SE 970140) (SE 950216) Features Suitable for standard 19 rack, flush, semiflush, projection

More information

MCC Ratings. Voltage Rating

MCC Ratings. Voltage Rating MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers

More information

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: Signed completed Electrical Permit application form. Minnesota law requires all electrical work is to be performed by licensed,

More information

TX3 Series TELEPHONE ACCESS SYSTEMS. Installation and Operation Manual

TX3 Series TELEPHONE ACCESS SYSTEMS. Installation and Operation Manual TX3 Series TELEPHONE ACCESS SYSTEMS Installation and Operation Manual Version 3.4 Mircom 1 (125) LT-969 Copyright September 2015 2 (125) Telephone Access System Installation and Operation Manual Version

More information

Power Distribution & Terminal Blocks

Power Distribution & Terminal Blocks Power Distribution & Terminal Section Contents Page Selection table for SCCR PDBs & Power terminal blocks................................ 294 Power distribution blocks Series PDBFS enclosed, with high

More information

FIELDPOINT BUS EXTENDER CABLE

FIELDPOINT BUS EXTENDER CABLE INSTALLATION GUIDE FIELDPOINT BUS EXTENDER CABLE If you have space constraints, you can use the FieldPoint Bus Extender Cable to mount a FieldPoint bank in two or three rows. Caution You should not use

More information

No Phone Line System. Quick Start Guide NPL II. 1.0 Installation

No Phone Line System. Quick Start Guide NPL II. 1.0 Installation Used in conjunction with EntraGuard Gold Telephone Entry Systems, the provides No Phone Line communication and door or gate control through existing building telephone lines without the need purchase phone

More information

LVA Take Offs in Bid Manager

LVA Take Offs in Bid Manager Electrical Sales and Distributor Training Low Voltage Assemblies (LVA) LVA Take Offs in Bid Manager This job aid helps to define some of the common selection questions that are encountered when configuring

More information

Testing Accessories. Test PaddleS. Insulated Socket Wrench Jumper Strips Test Lead Kit. Test Paddle Attachment Clips Plugs Binding Posts

Testing Accessories. Test PaddleS. Insulated Socket Wrench Jumper Strips Test Lead Kit. Test Paddle Attachment Clips Plugs Binding Posts Testing Accessories Test Paddles Test Paddle Attachment Clips Plugs Binding Posts Insulated Socket Wrench Jumper Strips Test Lead Kit Test PaddleS The 10 and 14 pole potential test paddles are feature

More information

TSn SERIES Surge Protective Device

TSn SERIES Surge Protective Device Page: 1 of 8 TSn SERIES Surge Protective Installation & Operation Manual 3621 Saunders Avenue www.systems.us Ph 804.355.1100 Richmond, VA 23227 4354 Sales@Systems.us Fax 804.355.8900 Page: 2 of 8 Quick

More information

PS6500 Storage Arrays Rack Mount Instructions

PS6500 Storage Arrays Rack Mount Instructions PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks

More information

Electrical Grounding. Appendix C

Electrical Grounding. Appendix C Appendix C Electrical Grounding Low-Voltage Equipment Grounding The most frequently cited Office of Safety and Health Administration (OSHA) electrical violation is improper occupational grounding of equipment

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

SECTION 3A (Rev.F) SECTION CONTENTS. Download from www.urmet.com Technical Manuals area. sec.3a INSTALLATION...9 TECHNICAL SPECIFICATIONS...

SECTION 3A (Rev.F) SECTION CONTENTS. Download from www.urmet.com Technical Manuals area. sec.3a INSTALLATION...9 TECHNICAL SPECIFICATIONS... SECTION 3A (Rev.F) Apartment door phone stations Download from www.urmet.com Technical Manuals area. ATLANTICO DOOR PHONES 2 TECHNICAL SPECIFICATIONS...2 4+n wire system door phones...2 Door phone with

More information

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264 BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used

More information

Bolted contact switches. Pringle switches

Bolted contact switches. Pringle switches Bolted contact switches Pringle switches Eaton s Pringle bolted contact switches History Eaton s PringleT switches have helped pioneer the development of high-quality electrical products for commercial

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

Fire Alarm System Accessories

Fire Alarm System Accessories Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer

More information

POWER WAVE 455M/STT & (CE)

POWER WAVE 455M/STT & (CE) Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies P-450 P-450 PARTS LIST FOR POWER WAVE 455M/STT & (CE) P-450-A P-450-A ILLUSTRATION

More information