Produced by Alan Ward

Size: px
Start display at page:

Download "Produced by Alan Ward"

Transcription

1 Produced by Alan Ward

2

3 Contents Approved Billing Meters 5 Electricity Act 1989 Measuring Instruments Directive Code of Practice 5 (CoP5) Renewable Obligations Certificate (ROC) Metering Elements of Sub Metering 9 Safety Wiring Regulations Types, Characteristics and Applications Accuracy and Standards Communication Options Electrical Connections Building Regulations L2 Energy Performance of Buildings Directive (EPBD) Enhanced Capital Allowances (ECA) Meter Accessories 15 Current Transformers (CT) Current Transformer Types and Polarity Accuracy and Burden Summation Current Transformers Conversion Plates Fuses and Links Meter Boxes Multi-meter Panels Meter Installation 20 Safety Common Faults Less Common Faults Specifying Sub-meters 22 UMS Ltd Products and Services 23 Application Profiles 24 Useful Contacts and Links 25 3

4 Introduction This booklet is designed to be a basic introduction to the subject of electricity sub-metering and not a definitive guide to installing any specific meter. All installation work should be carried out by a suitably qualified electrician who is fully conversant with the meter being installed and the latest wiring and safety regulations. If in doubt please contact the meter manufacturer before carrying out any work. 4

5 Approved Billing Meters Electricity Act 1989 In accordance with Schedule 7 of the 1989 Electricity Act, any reading used to bill a customer or tenant must be taken from a meter of an approved pattern or design. This is a subject that seems to cause a great deal of confusion but according to Ofgem the position is clear: In the commercial environment, the landlord may take a supply as a customer of an electricity supplier. Where the landlord installs a sub-meter for re-supply to his tenants, he becomes the authorised electricity supplier under Schedule 7(1)(10) of the Electricity Act. He is authorised by exemption (Class B: Resale schedule 4 of the exemptions order, SI 3270/2001) and his tenants become his customers. Generally, no meter shall be used for ascertaining the quantity of electricity supplied by an authorised supplier to a customer unless the meter is: a. of an approved pattern or construction and is installed in an approved manner according to the regulations; and b. is certified by a meter examiner or other person authorised to certify meters The landlord can be exempt from b. the requirement for certification, if the landlord has agreement in writing from his tenant before the meter is used (Schedule 7(2)(2). However, there is no exemption for a. the requirement for approved installation, as It is an offence for an authorised supplier to supply electricity through a meter that is not of an approved pattern. 5

6 Measuring Instruments Directive (MID) The European Measuring Instruments Directive came into force on the 30th of October MID is designed to create a single European market for approved meters so that a meter approved in one EU state can be used in any other EU state without any additional testing. What are the implications? 1. Ofgem is no longer the body responsible for approving meters for use in the UK. However, meters approved by Ofgem before MID can continue to be manufactured, verified and used for billing purposes. 2. Meters manufactured and approved for use in other EU member states can now be used in the UK without the additional need for Ofgem approval. The technical responsibility for managing the MID approval process has been transferred from Ofgem to the National Weights & Measures Laboratory (NWML). How can you be sure a meter is approved? Existing meters approved by Ofgem are listed in Schedule 4 and this can be downloaded from the Ofgem Website. Here you will find details of the manufacturer, meter designation and approval certification number. For meters approved under MID, the supplier will be able to provide details of the EU country where the meter was approved, the Nominated Body that carried out the approval and a certification/reference number confirming approval. 6

7 Code of Practice 5 (CoP5) Meters All sites rated above 100kW but below 1MW will have a CoP5 meter installed for billing purposes. These are special meters that record and store load survey data every 30 minutes, i.e 48 readings per day. These readings are collected daily via a communications link by an approved data collector. The data is then used to create the customer bill and the charges that the electricity suppliers have to pay for using the network to deliver the electricity. Although data is owned by the supply company, customers have the right to access and collect the data at no additional cost. Data can only be collected by customers between midday an midnight as the rest of the day is reserved for collection by the data collector for the purposes of billing and settlement. For a customer to access the data directly, agreement from the supplier is required and your Meter Operator, responsible for installation and maintenance of the system, will need to put a customer password into the meter. The meter manufacturer or a third party will be able to supply suitable software to access and process the data. Some electricity companies will offer to provide the data in a convenient format for downloading from a website but may make a charge for this service. Above 1MW CoP3 meters are used and these operate in a very similar way to CoP5 meters. Further information on Code of Practice metering can be found on the Ofgem website. 7

8 ROC Metering ROC stands for Renewable Obligation Certificate and since April 2002 all licensed electricity suppliers have been required to source a proportion of their electricity from renewables. The proportion is variable and increasing year on year. ROCs are not just for utility companies, any organisation can register with Ofgem and if accredited can obtain ROCs. 1 ROC is awarded for every 1MWh of electricity generated and once obtained ROCs can be sold on. Ofgem requires that any meter used for determining the amount of renewable electricity generated must be of an approved type i.e. Ofgem or MID approved and be installed in an approved manner. Electricity used by the generating equipment, often called the parasitic load, is deemed as input electricity. Input electricity must be deducted from the output electricity as it does not qualify for ROCs. Approved metering must also be used for measuring input electricity and any electricity exported from the site will require appropriate balancing and settlement code compliant metering. 8

9 Elements of Sub-metering The terms secondary or sub-metering usually refer to commercial or industrial applications downstream of the main billing meter. Safety Because of the dangerous voltages involved any invasive work should only be carried out by suitably qualified staff or contractors in accordance with current health and safety regulations. Wiring Regulations BS7671 came into force on 1st April 2006 and relates to EU harmonised colours and the alphanumeric marking of cables, conductors and terminals in new electrical installations. It is now not permissible to install equipment or wiring in the UK using the old colours (red, yellow & blue for phases, black for neutral). All conductors and terminals must be marked L1, L2, and L3. Conductors can be colour-coded either with new colours (brown, black & grey for phases, blue for neutral), or brown for all phases, blue for neutral. L1 L2 L3 N 9

10 Types, Characteristics and Applications There are three main designs of fixed electricity meter: surface mounted for fixing to a wall or on the front of an enclosure; panel mounted for installing in the front of an electrical panel and; din rail mounted for mounting in the back of a control panel. In addition to the design meters may have different characteristics to suit the application: Basic A kwh meter with display and kwh pulse used on switchgear outgoing supplies and for connection to a monitoring system. Used widely for compliance to the Building Regulations L2. Multi-function A multi-parameter meter with pulsed outputs and a range of communication options. Often used on the incoming supply to switchgear to provide additional information for the electrical engineer. This type of meter can be connected to a power monitoring or energy monitoring system. Power quality A specialised meter used to capture transient events and identify problems such as harmonics. Load profile A meter which can store half hourly load survey data for local or remote collection. Some have the ability to accept pulsed inputs from other devices such as gas and water and can be the basis of a very cost-effective monitoring system. Web enabled A meter with a built-in web server that can be read via your data network or via the internet using a standard browser. 10

11 Accuracy and Standards Class 1 accuracy is usually all that is required for sub-metering applications. Select a meter that meets a good international standard such as IEC/BS EN More importantly, buy your meter from a reputable manufacturer or supplier that can provide after-sales support for the life of the meter. For power quality meters use the international standard EN Communication options Pulsed output As a minimum the meter should have a kwh pulsed output. Meters that also offer a second output for kvah or kvarh will allow power factor and kva or kvar Maximum Demand to be monitored. Pulse counting is relatively crude and long-term accuracy from a remote monitoring system cannot be guaranteed. Analogue signals These signals can be fed into SCADA systems for the continuous monitoring of voltage and current etc. Serial Here data is passed from the meter to a PC in response to a question. This type of communication is superior to pulses because the data is authenticated meaning the reading from the monitoring system will always match the meter. Serial bus RS485 Modbus is a very common, low cost way of communicating with a large number of meters over long distances. 11

12 Electrical Connections The majority of sub-meters sold in the UK are 230V, 3 phase, 4 wire and require current transformers (CTs) above 100A current rating. In this configuration of three phases and a neutral, three CTs are required, one for each phase. If the meter has internal CTs the secondary lead from each CT can be commoned together, reducing the amount of cabling needed. Not all three phase supplies have a neutral e.g. motor control systems. With these 400V, 3 phase, 3 wire applications only two CTs are required for accurate measurement. High voltage systems are also 3 phase, 3 wire but in addition to using two CTs, voltage transformers are used to reduce the voltage to a safe 110V. Most industrial HV applications are 11000V although 6600V is still common on some sites. 230V 3 Phase 4 Wire Connections Voltage Inputs CT Inputs 230V 400V V1 V2 V3 Vn in 1 out in 2 out in 3 out V Fuses 1 N L1 L2 L3 N 2 3 S1S2 S1S2 S1S2 P1P2 No Load P1P2 P1P2 Current Transformers 12

13 Building Regulations L2 These new regulations came into effect in 2002 and are designed to improve the monitoring of energy consumption within buildings, with a view to reducing carbon emissions. The regulations relate to new buildings or major refurbishment. Section 3.4 states Reasonable provision would be to enable at least 90% of the estimated annual energy consumption of each fuel to be accounted for. An appropriate metering strategy needs to be put in place and detailed in the building log book. Guidance regarding an appropriate meter scheme is provided as follows: Each separate building or tenanted areas over 500m 2 (Please note if the tenant meter is also to be used to generate the bill, an approved meter must be used). Boilers / CHP plant 50kW and above Chillers 20kW and above Electric humidifiers 10kW and above Motor control centres, pumps and fans above 10kW Electrical distribution boards, circuits above 50kW Any process load that is to be excluded from the benchmarking process. All three phase supplies of 75A and above will need to be metered. For single phase supplies the current rating will need to be above 200A before metering is needed unless the supply is for chillers or pumps etc, as detailed above. 13

14 Energy Performance of Buildings Directive (EPBD) The European Union Energy Performance of Buildings Directive was published in the Official Journal on the 4th January The overall objective of the Directive is to: promote the improvement of energy performance of buildings within the community taking into account outdoor climatic and local conditions, as well as indoor climate requirements and cost-effectiveness. Each EU member state was required to transpose the Directive into law by the beginning of 2006 with a further three years being allowed for full implementation of specific articles. Enhanced Capital Allowances (ECA) As part of the Government s commitment to reducing CO 2 emissions, businesses investing in certain energy-saving technologies can benefit from a significant tax break (100% first year capital allowance). These technologies include electricity meters to IEC / EN61036 or BS8431 when used as part of an Automatic Monitoring and Targeting system that meets the required criteria. For further information visit the ECA website at 14

15 Meter Accessories Current Transformers There are a number of reasons for using CTs but the main reason is to do with the physical size of current-carrying cables above A. To accept large diameter cables and to provide adequate insulation the meter would need to be very big and therefore very expensive. Because CTs are able to provide a secondary output with a linear relationship to the primary current, meters can be manufactured in a compact form and at relatively low cost. Generally, 1A or 5A secondary outputs are available with 5A being the most commonly used on new switchgear. If the transformers are likely to be some distance from the meter a 1A CT may be selected in order to keep line losses to a minimum. A CT rated at 600:5 will provide 5A to the meter when the primary current is 600A and 2.5A when the primary current is 300A. For most secondary metering applications it is usually acceptable to use class 1 metering grade CTs. This means at full load, the accuracy will be +/- 1% of the actual current. When combined with a meter offering +/- 1% the overall accuracy of the system, assuming there are no wiring or burden problems, will be +/- 2%. 15

16 Current Transformer Type and Polarity The most common type of metering grade CT is the moulded case type and is suitable for cable or busbar mounting. This is fine for new switchgear installations but not easy to retro-fit to existing switchgear on site. Disconnecting large cables in order to feed them through CTs can be difficult and time consuming, so installers usually prefer to fit split core CTs. All CTs have S1 and S2 secondary terminals that need to be wired to the respective terminals on the meter. The current should flow from S1 to the meter and then back to the CT through S2 in order to maintain the correct polarity and drive the meter registers forward. Current Transformer Accuracy and Burden Manufacturers will not only declare the accuracy of their CTs but also the burden they can handle without compromising that accuracy. Typically a 5A secondary CT will be offered with a 5VA burden rating at Class 1 accuracy. Where any current flows through a device or wire it will meet impedance and resistance. The total burden a CT will need to overcome is calculated by adding together the burden from any device connected such as a meter or summation CT, together with the burden from the secondary wiring. Charts are available to help calculate these wiring losses. 16

17 Burden Charts 1A Cable Size mm mm mm 2 4.0mm Distance (metres) Chart showing relationship between burden and distance for varying cable sizes and a 1A CT Burden (VA) 5A Cable Size mm mm mm 2 4.0mm 2 6.0mm mm Distance (metres) Chart showing relationship between burden and distance for varying cable sizes and a 5A CT 17

18 Summation Current Transformers If a number of outgoing supplies from a switch panel need to be combined to give total consumption for a cost centre, a convenient way to do this is to use summation CTs. Several supplies can be summated but note that the more supplies summated the more difficult it is to resolve any resulting wiring problems. For example if we wish to summate 3 off 3 phase supplies rated at 300:5*, we will need to use 3 summation CTs, one for each phase. These will be rated 5+5+5:5. In other words each summation CT will take in three 5A currents and provide a 5A output to the meter. The meter in turn must be set to the sum of the primary currents = 900A. * The CT primaries must balance in order to give reasonable results and this may mean using a 300A CT on a 100A supply. However, as CTs operate accurately over a wide dynamic range, reasonable accuracy can be achieved. Conversion plates There are still many old electro-mechanical meters in use and the majority do not have a pulsed output. These old meters will need to be replaced if an automatic monitoring system is being installed. Modern digital meters with pulsed outputs are a standard Din 96 size and so will not fit the hole left by the old meter. This problem is easily resolved using a conversion plate usually made of steel and large enough to cover the hole left by the old meter and with a Din 96 hole cut centrally to accept the new meter. 18

19 Fuses and Links It is good practice to fit isolation fuses and CT shorting links so that the meter can be safely isolated in the case of failure or more commonly if an installation wiring fault needs to be corrected. Generally digital meters are designed for 10 years reliable operation but the CTs having no moving or electronic parts, can be used for 30 or more years. Meter Boxes Meter boxes are sometimes used where it is not possible or practical to fit a meter in the existing switchgear. A wall mounting box housing a meter with fuses and shorting links inside is a good solution in these circumstances. Multi-meter Panels If a number of meters are required but cannot be installed on existing switchgear it may be necessary to have a purpose-built panel made. If the purpose of installing the meters is for automatic monitoring then the output from all the meters can be very easily wired within the panel and out to a logger or BMS outstation. 19

20 Meter Installation Safety is always of prime importance so you should only use an installer who is suitably qualified and understands the dangers involved when fitting electricity meters and CTs. Not all electricians are aware of the dangers of leaving CTs open-circuit and the resulting voltages that build up in the wiring. Many meter suppliers will offer to fit and commission the meters and this is the simplest option to take. Using your own electricians will save money and allow the work to be done with minimal disruption to production. The advice here is to make sure the electricians fully understand the job in hand and read the installation manual before starting work. It is sensible to get the supplier to visit site once the work is complete to carry out a commissioning check so that any wiring faults can be corrected. Most unsatisfactory meter projects are due to incorrect installation rather than faulty meters. Common Faults By far the most common fault is incorrect CT polarity where one or more of the CTs have been installed the wrong way round. Assuming the phase loading is balanced, if one of the CTs has reversed polarity it will effectively cancel out one of the two correctly installed CTs and the meter will only be reading a third of the output. If two or more CTs are reversed the meter will not work at all. Clearly if the CTs have been correctly installed but the wiring from one or more of the CTs has been reversed the meter will not operate accurately. 20

21 Another common fault occurs where there is a mismatch between the voltage and current connections to the meter. e.g. if the brown phase voltage is connected to the black phase and the black phase voltage is connected to the grey phase. In order to work accurately meters need to be able to measure not only voltage and current but also the relationship between the waveforms. A shifting of the phase relationship by 120 degrees as described above will confuse the meter and lead to inaccurate readings such as a peculiar power factor. It is very difficult to diagnose this type of fault unless you have an intelligent meter with diagnostics built in. Less Common Faults Correct installation is as important as selecting the right meter for the job, it needs careful consideration. Make sure the CT cabling is adequate and does not overburden the CT. Using 1.5mm 2 cable to carry a 5A secondary current 30 metres to the other side of a switch room will lead to poor accuracy. Check the CT burden charts to make sure the cable is adequate for the job or if you are unsure contact your supplier. Installing CTs on the wrong supply happens more often than you would imagine. The same problem will occur if the cabling to a multi-meter panel gets crossed en route. 21

22 Specifying Sub-meters There is a new British standard for solid state secondary or sub-meters. The argument from a number of manufacturers is that a standard exists for tariff metering (the main billing meter) IEC/BS EN and that a less arduous standard is needed for sub-metering to cover the very wide range of applications secondary metering is used for. However, most good quality sub-meters already meet the international standard IEC/BS EN and at no extra cost. If your main concern is reliable accuracy then simply specify IEC/BS EN From the point of view of the meter specifier it is important to bear a number of points in mind: Accuracy is important and purchasing a class 1 meter which complies with IEC/BS EN will not cost much more than a class 3 device. Use metering grade CTs and specify class 1 accuracy as a minimum. Consider also the whole system and ensure line losses are within the limits of the CT. For tenant billing applications, select meters which are pattern approved for the purpose by Ofgem or have MID approval.. All meters should be installed with fuses and CT shorting links so that for servicing purposes the meter can be fully isolated from the system. Select a meter supplier, a manufacturer or distributor who can provide good technical support. Many metering problems are installation or site related so if things go wrong you may need expert help on site. 22

23 Utility Metering Solutions Ltd. Utility Metering Solutions offers expert guidance on meter selection and a professional installation and commissioning service for meters, data networks and software. Products and Services Electricity Meters Basic kwh with Pulse Multi-function meters with communications Web enabled and power quality meters Ofgem and MID approved billing meters Ancillaries Class 1 metering grade current transformers Fuses and CT shorting link assemblies Single boxes and multi-meter panels Conversion plates for replacing old meters Communication and data logging Multi-channel data loggers Data collecting via Ethernet and internet PSTN and GSM / GPRS modems Software For handheld data collection Automatic collection and analysis Automatic tenant billing Services Consultancy services Site surveys and reports Meter and communications installation Supply/install gas, water, and other utility meters Bureau services 23

24 Application Profiles Company A A large quarry needed to take control of its electricity use with an AMR solution. As the substations were not connected to the phone or data network and as it was not practical to run cables, a GSM solution was devised. Premier meters were installed with GSM modems and linked back to AMR software via the cellular network. Premier meters store half hourly load survey and only need to be contacted once a day for the data to be collected. The result is a very reliable and cost effective solution. Organisation B Government offices wishing to reduce carbon emissions contacted UMS for a turnkey solution. Following a site visit and the provision of a detailed quotation, UMS were commissioned to supply the complete solution. Elite panel meters were installed in the main switchgear and networked to a PC running EASEII Manager software. This solution not only allows load profiling and reporting but also access to real-time power consumption. During the commissioning stage the air curtain system was shown to be running at full load (22kW) 24/7 with no controls. Real-time monitoring can be a very powerful tool in reducing waste and carbon emissions as the impact of switching off unnecessary loads can be seen immediately. Commercial Offices C A major refurbishment had been carried out in an office block but the metering had been overlooked. UMS had been recommended to the managing agents and within a few weeks Ofgem approved billing meters had been installed for billing the commercial tenants. Although automatic meter reading and billing was not required at this stage the meters have the capacity to be networked and read remotely in the future. 24

25 Contractor D Installed Ofgem approved metering on a ROCs scheme. Two identical CHP units are powered from methane gas produced at a sewage works. However, the ROC CHP meters did not agree with the CHP 2 meter showing a consistently lower reading than the CHP 1 meter. Following investigations carried out by the UMS engineer, the problem was traced to a faulty current transformer on one of the phases. Useful Contacts and Links ESTA The Energy Services & Technology Association Ofgem NWML National Weights & Measures Laboratory Building Energy Metering Guide TM39 available from CIBSE Carbon Trust 25

26 26 Notes

27

28 If you would like advice or information on the areas covered in this booklet please contact: Utility Metering Solutions Ltd Po Box 9129 Nottingham NG2 9EH The UMS Guide to Metering was written by Alan Ward for UMS Ltd.

CURRENT TRANSFORMERS INSTALLATION GUIDE

CURRENT TRANSFORMERS INSTALLATION GUIDE CURRENT TRANSFORMERS INSTALLATION GUIDE Information contained within this document is subject to change without notice and does not represent a commitment on the part of PRI Ltd or its agents. E&OE. Copyright

More information

scalable data centre energy management solution

scalable data centre energy management solution scalable data centre energy management solution scalable data centre energy management solution EcoMeasure - Scalable Data Centre Energy Management & Efficiency Measurement Solution by Workspace Technology

More information

Case Study - University at Buffalo State University of New York. Lower Energy Usage Costs with Real Time Monitoring, Campus-wide

Case Study - University at Buffalo State University of New York. Lower Energy Usage Costs with Real Time Monitoring, Campus-wide Case Study - University at Buffalo State University of New York Lower Energy Usage Costs with Real Time Monitoring, Campus-wide Reduce Energy Consumption through Awareness of Energy Use Analyze Power Quality

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

MID Guide onsultancy eters

MID Guide onsultancy eters MID Guide Consultancy Meters Our commitment to our clients is to deliver excellence through the expertise of our staff, by the innovation of our engineers, and with the integrity of the Company. SHM has

More information

Carbon Path to 2020. Alan Aldridge Executive Director Energy Services and Technology Association

Carbon Path to 2020. Alan Aldridge Executive Director Energy Services and Technology Association Carbon Path to 2020 Alan Aldridge Executive Director Energy Services and Technology Association ESTA PO Box 77 Benfleet Essex SS7 5EX T: 01268 569010 F: 01268 569737 E: info@esta.org.uk W: www.esta.org.uk

More information

ELECTRICAL POWER MEASUREMENT: THE IMPACT OF PART L2 OF THE BUILDING REGULATIONS

ELECTRICAL POWER MEASUREMENT: THE IMPACT OF PART L2 OF THE BUILDING REGULATIONS ELECTRICAL POWER MEASUREMENT: THE IMPACT OF PART L2 OF THE BUILDING REGULATIONS By David Pitt, Product Marketing Manager, Power Distribution Components, Eaton Executive summary Part L2 of the Building

More information

A project to optimise quality and energy efficiency must include metering

A project to optimise quality and energy efficiency must include metering EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,

More information

Current Transformers

Current Transformers Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 Current Transformers Current transformers (CT's) provide

More information

ENERGY AUDITING AND MONITORING IN COMPANIES

ENERGY AUDITING AND MONITORING IN COMPANIES ENERGY AUDITING AND MONITORING IN COMPANIES Introduction To implement Article 8 (-6) of the EU Energy Efficiency Directive (0/7/EU), the UK government has set up ESOS (Energy Savings Opportunity Scheme)

More information

Electricity Terminology. Simplifying energy management

Electricity Terminology. Simplifying energy management Simplifying energy management AMR Automated Meter Reading - automatic collection of data from meters which is transferred to a central database for billing and/or analysis. Balancing Mechanism The mechanism

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications The ZigBee Plug & Play wireless Network for Building and Industrial Applications Energy Management Renewable Monitoring Environment Monitoring Open Modbus Integration Products Range Overview Products Range

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Metering, Billing & Remote Surveillance. Solutions for Communal Heating Systems - Including SmartTalk Two-Way Communication

Metering, Billing & Remote Surveillance. Solutions for Communal Heating Systems - Including SmartTalk Two-Way Communication Metering, Billing & Remote Surveillance Solutions for Communal Heating Systems - Including SmartTalk Two-Way Communication 1 Metering, Billing & Remote Surveillance Solutions Evinox Energy specialise in

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

Operation of electricity meters when energy flowing in reverse

Operation of electricity meters when energy flowing in reverse Title: Operation of electricity meters when energy flowing in reverse Synopsis: To document the impact of reverse energy flow of whole current import electricity meters Date: 20 th August 2013 Prepared

More information

Sinergy sub-metering The knowledge you need to reduce energy usage

Sinergy sub-metering The knowledge you need to reduce energy usage Marshall Tufflex Energy Management www.marshalltufflexenergy.com Sinergy sub-metering The knowledge you need to reduce energy usage Reducing your energy consumption Do you need to reduce your energy bills,

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

Energy Display Meter User Guide Engage, educate and inspire smart energy usage

Energy Display Meter User Guide Engage, educate and inspire smart energy usage Energy Display Meter User Guide Engage, educate and inspire smart energy usage Introducing your new Energy Display Meter This user guide is designed to provide you with all you need to know about the new

More information

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850

More information

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.

More information

Polyphase kwh Electricity Meter

Polyphase kwh Electricity Meter Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information

Metering for today s systems

Metering for today s systems Metering for today s systems The sub-meter gathers data on the building side of the utility company meter. This allows us to break out usage so data can be collected from individual circuits, a single

More information

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General A. Electrical usage on the Brown campus is presently monitored by a Siemens-brand, web-based central metering system, which includes

More information

Process Alarm Solutions

Process Alarm Solutions Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

CODE OF PRACTICE NINE

CODE OF PRACTICE NINE CODE OF PRACTICE NINE CODE OF PRACTICE FOR THE METERING OF IMPORT AND EXPORT ACTIVE ENERGY VIA LOW VOLTAGE CIRCUITS FOR NON-HALF HOURLY SETTLEMENT PURPOSES Issue 1 Version 5.0 DATE: 26 November 2009 Balancing

More information

G8 - Contracts for Difference Metering

G8 - Contracts for Difference Metering PUBLIC G8 - Contracts for Difference Metering EMRS Guidance EMR Settlement Limited Version 1.0 12 October 2015 CONTENTS Change Amendment Record...4 1. Introduction...5 2. Purpose...5 3. What is the Electrical

More information

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm

More information

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide GB05-6 Peak Atlas IT RJ45 Network Cable Analyser Model UTP05 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2001/2012 In the interests of development, information

More information

Panorama Electricity meters For reliable values of energy consumption

Panorama Electricity meters For reliable values of energy consumption Panorama Electricity meters For reliable values of energy consumption Why measure Electrical Energy Energy cost is on the rise. It is therefore in the interest of both private and commercial customers

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS Meher Capacitors offers reliable and innovative products and solutions in the fields of Reactive Power Compensation, Power Quality and Energy

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

LOW-VOLTAGE CURRENT TRANSFORMERS

LOW-VOLTAGE CURRENT TRANSFORMERS LOWVOLTAGE CURRENT TRANSFORMERS 5 A Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) 45 75 39; 45 75 305; 45 75 3; 45 75 368; email: export@lumel.com.pl ul. Słubicka 657 Zielona Góra CONTENTS

More information

TX2123 RS485 TO ETHERNET ADAPTOR

TX2123 RS485 TO ETHERNET ADAPTOR TX2123 RS485 TO ETHERNET ADAPTOR Converts Datacomms between fibre optic Modbus TCP over Ethernet and hard-wired copper Modbus RTU over RS485 Fibre Optic MODBUS TCP/ IP Ethernet Copper MODBUS RTU RS485

More information

EARTH LEAKAGE PROTECTION: CONTENTS

EARTH LEAKAGE PROTECTION: CONTENTS EARTH LEAKAGE PROTECTION: CONTENTS Earth Leakage Relays 128-130 Trip Circuit Supervision Relays 128-130 TEMPROTECT Protection and Distribution 1A to 6300A page 127 EARTH LEAKAGE PROTECTION ELR-1E The ELR-1E

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Problem / Solution. The problem:

Problem / Solution. The problem: Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is

More information

Nu-Lec Training Modules

Nu-Lec Training Modules PTCC Controller Nu-Lec Training Modules Product Training Operator Training PTCC The Basics An overview of the construction and physical features of the Pole Top Control Cubicle PTCC Operation and Features

More information

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants Installation instructions Contents Key points of installation Before installation Installation Installation check

More information

Applications. diris_826_a_1_gb_cat

Applications. diris_826_a_1_gb_cat Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered

More information

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV 1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled

More information

Solar Power Frequently Asked Questions

Solar Power Frequently Asked Questions General information about solar power 1. How do I get solar power? Solar Power Frequently Asked Questions Many companies install solar power systems including some electricity retailers. It is worth comparing

More information

GE Power Controls. MiniFORM Switchboards

GE Power Controls. MiniFORM Switchboards GE Power Controls MiniFORM Switchboards MiniFORM MiniFORM MiniFORM switchboards Arrangement Modules Arrangement modules 1-6 6 Arrangement modules 7-12 7 Arrangement modules 12-14 8 Arrangement modules

More information

Maximum Demand Control

Maximum Demand Control Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility

More information

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management Energy Depot GmbH Delivering Solutions for Energy Management PRODUCT AND APPLICATION GUIDE Total Monitoring Solution for PV SOLAR LOGGER & ANALYSIS DC STRING MONITORING Residential Comprehensive Solar

More information

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision

More information

Installation Guide Solar Connect-11

Installation Guide Solar Connect-11 Installation Guide Solar Connect-11 Version 1.1 Contents Important Product Information 3 System Registration Form 4 Solar Connect-11 Overview 5 Internet & Power Connections 6 Single Phase CT Connections

More information

Estimation of electrical losses in Network Rail Electrification Systems

Estimation of electrical losses in Network Rail Electrification Systems Estimation of electrical losses in Network Rail Electrification Systems Page 1 of 16 Contents 1. BACKGROUND...3 2. PURPOSE...3 3. SCOPE...3 4. DEFINITIONS & ABBREVIATIONS...4 5. NETWORK RAIL INFRASTRUCTURE

More information

How To Get A Power Line Extension

How To Get A Power Line Extension GUIDELINES FOR COMMERCIAL ELECTRIC SERVICE HOOKUP 1 Steps to Commercial Service Pay the Design Deposit Commercial Buildings: Up to 1, sq ft = $1,. 1, 5, sq ft = $2,. Over 5, sq ft = $3,. Commercial jobs

More information

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) DETAILS OF THE CLEINT Client and address ADDRESS OF THE INSTALLATION Installation

More information

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series Communication system for the management of electrical installations INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series MID Approval Technology for energy efficiency PLC Communications (Power Line Communication)

More information

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE

More information

ES281 COMPANY-SPECIFIC APPENDICES TO ENA ENGINEERING RECOMMENDATION G81 PART 1

ES281 COMPANY-SPECIFIC APPENDICES TO ENA ENGINEERING RECOMMENDATION G81 PART 1 ES281 COMPANY-SPECIFIC APPENDICES TO ENA ENGINEERING RECOMMENDATION G81 PART 1 Design and Planning Specification for New Low Voltage Installations for Housing Developments 1. SCOPE This appendix to ENA

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Geoff Chapman Sales & Marketing Manager. ESTA Nov 2009 event AMR & CRC

Geoff Chapman Sales & Marketing Manager. ESTA Nov 2009 event AMR & CRC Geoff Chapman Sales & Marketing Manager CRC Energy Efficiency Scheme Carbon Reduction Commitment is now known as CRC Energy Efficiency Scheme (CRC) Third consultation Government response 7 th October 2009

More information

Brochure. Electricity meters For increased awareness

Brochure. Electricity meters For increased awareness Brochure Electricity meters For increased awareness Strike the perfect balance with EQ meters In the World Energy outlook for 2012 the International Energy Agency (IEA), states: A significant share of

More information

Simple Electrical Utility Cost Allocation Solutions

Simple Electrical Utility Cost Allocation Solutions Simple Electrical Utility Cost Allocation Solutions PowerLogic High Density Metering Advanced Submetering and Multi-Tenant Metering Buildings Retail Multi Residential DATA CENTER SOLUTIONS For More Information:

More information

Documentation. M-Bus 130-mbx

Documentation. M-Bus 130-mbx Documentation M-Bus 130-mbx Introduction The mx M-Bus module is part of the mx Smart Slot communications family. With the integrated SmartSlot technology, mx systems ag offers automatic consumer data read-out

More information

Heating and Hot Water Services Controls General Technical Specification

Heating and Hot Water Services Controls General Technical Specification Construction Services Heating and Hot Water Services Controls General Technical Specification Version 1.0 Environment Heating and Hot Water Services Controls General Technical Specification Contents 1.

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Communicate and view data from meters with one simple device

Communicate and view data from meters with one simple device Communicate and view data from meters with one simple device PowerLogic EGX300 integrated gateway-server Web Monitoring Communications Plug and Play Plug into your energy usage with a simple mouse click

More information

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

Standard terms and conditions

Standard terms and conditions Standard terms and conditions For small and medium enterprises (SMEs) including micro businesses. Effective from 31 March 2014 Helping our customers. We re on it. 1 Contents Section 1 Taking over premises

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design Basis of Design This section applies to the design, installation and integration of metering and monitoring equipment, including: hardware installed in the electrical service and distribution equipment,

More information

ScottishPower Distribution Cables & Equipment. Metal Theft

ScottishPower Distribution Cables & Equipment. Metal Theft ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated

More information

Everything you need for protection scheme testing

Everything you need for protection scheme testing Power System Simulator for Testing Protection Relays and Schemes Everything you need for protection scheme testing The is the only instrument with the high power, flexibility and software to perform full

More information

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03 PRO370D 65A Mbus MID DIN rail three phase four wire energy meter User manual Version 1.03 1 Safety instructions... 3 2 Foreword... 4 3 CE certificates... 5 4 MID certificate... 7 5 Performance criteria...

More information

Application Note: Monitoring Branch Circuit Loads in Critical Facilities

Application Note: Monitoring Branch Circuit Loads in Critical Facilities Application Note: Monitoring Branch Circuit Loads in Critical Facilities Description of application: The AcquiSuite data acquisition server (DAS) from Obvius is used to monitor the electrical loads and

More information

www.electroind.com. March 15th 2005 EI Solutions - Submetering 1

www.electroind.com. March 15th 2005 EI Solutions - Submetering 1 . March 15th 2005 EI Solutions - Submetering 1 What is Submetering? Electric Service Master Meter Utility Owned POCC Utility Billing Point Sub Meter Electric Distribution Sub Meter Sub Meter Sub Meter

More information

Current Transformers

Current Transformers Supersedes December 2002 General Description Eaton s low voltage current transformers are available in both solid core and split core designs. Engineered for electronic metering applications, all solid

More information

WEB log. Device connection plans

WEB log. Device connection plans WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20151210* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,

More information

5.2. Overview. The better method to install solderless compression connectors on power cable

5.2. Overview. The better method to install solderless compression connectors on power cable 5.2 Overview The better method to install solderless compression connectors on power cable The Thomas & Betts method of installing compression connectors on power cables is designed to provide a high degree

More information

EnergySmart monitor user instructions

EnergySmart monitor user instructions EnergySmart monitor user instructions britishgas.co.uk/energysmart Your new EnergySmart monitor has arrived It s a great way to learn how to use less electricity and save money, and just one of the ways

More information

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting 12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.

More information

Installation Guide for Hive Active Heating

Installation Guide for Hive Active Heating Installation Guide for Hive Active Heating Important note: Installation should only ever be carried out by a qualified engineer. Technical Support If you need to contact Hive s Technical Support team during

More information

ENERGY AWARE. Monitor User Guide

ENERGY AWARE. Monitor User Guide ENERGY AWARE Monitor User Guide Table of contents Introduction 3 How it works 4 Have you got everything? 4 Before you get started 5 Setting up your TREC Display 6 Pairing the TREC Display and Transmitter

More information

Current Monitoring Kit QUICK START GUIDE

Current Monitoring Kit QUICK START GUIDE Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...

More information

Earthing Guidance Notes

Earthing Guidance Notes Central Networks Earthing Manual Section E2 Earthing Guidance Notes Version: 2 Date of Issue: September 2007 Author: Nigel Johnson Job Title: Earthing Specialist Approver: John Simpson Job Title: Head

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

TECHNICAL BRIEF. Commercial PV in Australia and New Zealand Using the Enphase Microinverter System

TECHNICAL BRIEF. Commercial PV in Australia and New Zealand Using the Enphase Microinverter System TECHNICAL BRIEF Commercial PV in Australia and New Zealand Using the Enphase Microinverter System 2015 Enphase Energy Inc. All rights reserved May 2015 Table of Contents Commercial PV in Australia and

More information

Elster Metering Systems. EC Directive 2004/22/EC

Elster Metering Systems. EC Directive 2004/22/EC EC Type Examination Certificate Number: UK/ 0120/ SGS0010 Elster Metering Systems Instrument Identification: A1100, Electricity Meter, LB********* Poly Phase, Credit, Active Import/ Export, Multi-rate,

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

Commercial Heating and Ventilation

Commercial Heating and Ventilation Commercial Heating and Ventilation Providing a comprehensive range of heating and ventilation solutions to local authorities, registered social landlords and commercial properties for over 35 years, Oakray

More information

Products and solutions for pumping, irrigation and piping

Products and solutions for pumping, irrigation and piping Products and solutions for pumping, irrigation and piping 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric

More information

Current Monitoring Kit

Current Monitoring Kit Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added

More information

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault

More information

Current Transformer (CT) Selection Guide

Current Transformer (CT) Selection Guide Current Transformer (CT) Selection Guide Article ESA-1008D December 5, 2014 Contents 1 Introduction.............................................. 3 1.1 Extending CT leads.......................................

More information

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING There are several ways to wire multiple batteries to achieve the correct battery voltage or capacity for a particular DC

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server Gain energy insight and control with PowerLogic PowerLogic EGX300 integrated gateway-server Plug into your energy usage with a simple mouse click The PowerLogic EGX300 is an integrated gateway-server that

More information

E350 series 2. Electricity Meters IEC/MID Residential. ZxF100Ax/Cx. User Manual

E350 series 2. Electricity Meters IEC/MID Residential. ZxF100Ax/Cx. User Manual Electricity Meters IEC/MID Residential ZxF100Ax/Cx E350 series 2 User Manual Date: 20.12.2011 File name: D000027979 E350 ZxF100Ax Cx series 2 User Manual EN.docx Landis+Gyr D000027979 EN n 2/54 Revision

More information

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown Self-Regulating 920 Series Dual-point heat-tracing control system Power-Limiting Mineral Insulated 920*E4FWL*SIS302*SS3102 shown Product overview The DigiTrace 920 is a compact, full-featured, microprocessor-based,

More information

KAM 25-32 A Lighting Busbar System KAP 40-63 A Plug-in Busbar Distribution System

KAM 25-32 A Lighting Busbar System KAP 40-63 A Plug-in Busbar Distribution System 2-32 A Lighting Busbar System 4-63 A Plug-in Busbar Distribution System / E-LINE KX Compact Busbar Distribution System 63...63 A E-LINE KB Compact Busbar Distribution System 8...63 A E-LINE KO Plug-in

More information