DATA CENTER FREE COOLING STRATEGIES. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Similar documents
CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

In Row Cooling Options for High Density IT Applications

How to Build a Data Centre Cooling Budget. Ian Cathcart

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

Rittal White Paper 507: Understanding Data Center Cooling Energy Usage & Reduction Methods By: Daniel Kennedy

Improving Data Center Energy Efficiency Through Environmental Optimization

White Paper. Data Center Containment Cooling Strategies. Abstract WHITE PAPER EC9001. Geist Updated August 2010

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

STULZ Water-Side Economizer Solutions

National Grid Your Partner in Energy Solutions

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers

The Different Types of Air Conditioning Equipment for IT Environments

Climate solutions. evaporative cooling, adiabatic humidification and programmable controllers. energy saving solutions for data centers. carel.

CRITICAL COOLING FOR DATA CENTERS

AIRAH Presentation April 30 th 2014

Elements of Energy Efficiency in Data Centre Cooling Architecture

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Managing Data Centre Heat Issues

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

How To Improve Energy Efficiency Through Raising Inlet Temperatures

Data Centers WHAT S ONTHEHORIZON FOR NR HVAC IN TITLE ? SLIDE 1

The New Data Center Cooling Paradigm The Tiered Approach

Defining Quality. Building Comfort. Precision. Air Conditioning

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Wet Bulb Temperature and Its Impact on Building Performance

Recommendation For Incorporating Data Center Specific Sustainability Best Practices into EO13514 Implementation

Self-benchmarking Guide for Data Center Infrastructure: Metrics, Benchmarks, Actions Sponsored by:

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Benefits of. Air Flow Management. Data Center

State of the Art Energy Efficient Data Centre Air Conditioning

APC APPLICATION NOTE #112

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

DOE FEMP First Thursday Seminar. Learner Guide. Core Competency Areas Addressed in the Training. Energy/Sustainability Managers and Facility Managers

Element D Services Heating, Ventilating, and Air Conditioning

Environmental Data Center Management and Monitoring

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

White Paper #10. Energy Efficiency in Computer Data Centers

GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.

Benefits of Cold Aisle Containment During Cooling Failure

BICSInews. plus. july/august Industrial-grade Infrastructure. + I Say Bonding, You Say Grounding + Data Center Containment.

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Data Centre Cooling Air Performance Metrics

Analysis of data centre cooling energy efficiency

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Free Cooling for Data Centers

Energy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Center Thermal Management Can Live Together

European Code of Conduct for Data Centre. Presentation of the Awards 2014

Data Center Energy Profiler Questions Checklist

Rittal White Paper 508: Economized Data Center Cooling Defining Methods & Implementation Practices By: Daniel Kennedy

Cooling Audit for Identifying Potential Cooling Problems in Data Centers

Trends in Data Center Design ASHRAE Leads the Way to Large Energy Savings

High Altitude HVAC. Silvertip Integrated Engineering Consultants

CHILLER PLANT CONTROL MULTIPLE CHILLER CONTROLS

Data Center Components Overview

Stanford University Server/Telecom Rooms Design Guide

How To Improve Energy Efficiency In A Data Center

Alan Matzka, P.E., Senior Mechanical Engineer Bradford Consulting Engineers

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

Top 5 Trends in Data Center Energy Efficiency

Legacy Data Centres Upgrading the cooling capabilities What are the options?

- White Paper - Data Centre Cooling. Best Practice

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Green Data Centre Design

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Direct Fresh Air Free Cooling of Data Centres

White Paper Rack climate control in data centres

Technical Systems. Helen Bedford

HVAC Systems: Overview

Dehumidification Frequently Asked Questions

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

European Code of Conduct for Data Centre. Presentation of the Awards 2013

Economizer Modes of Data Center Cooling Systems

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

Guide to Minimizing Compressor-based Cooling in Data Centers

How and Why Mission- Critical Cooling Systems Differ From Common Air Conditioners

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Blade Servers and Beyond: Adaptive Cooling for the Next Generation of IT Systems. A White Paper from the Experts in Business-Critical Continuity

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 4, Lancaster University, 2 nd July 2014

QUALITATIVE ANALYSIS OF COOLING ARCHITECTURES FOR DATA CENTERS

The Effect of Data Centre Environment on IT Reliability & Energy Consumption

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

Critical Infrastructure for the World s Leading Data Centers

Airflow Simulation Solves Data Centre Cooling Problem

Using Wet-Bulb Economizers. Data Center Cooling

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

Transcription:

DATA CENTER FREE COOLING STRATEGIES Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

OVERVIEW Understand the different types of economizers. Learn how free cooling contributes to energy efficiency and acceptable temperatures in Data Centers. See best practices for year-round economizer operation. Weigh the benefits of economizers with the potential drawbacks.

FREE COOLING STRATEGIES Free Cooling Airside Economizer Waterside Economizer Pumped Refrigerant Adiabatic Cooling

FREE COOLING AIR SIDE Direct Air Exchange T RH F I L T E R T RH Data Center Greatest Energy Savings Longer Free Cooling Periods Humidity Control Key Not Ideal for All Climates Sensible & Latent Capacity IT IT

FREE COOLING AIR SIDE Heat Exchanger T RH Data Center T RH Sensible Capacity Only Slightly Less Energy Savings Slightly Shorter Free Cooling Periods Slightly More $$ IT IT

FREE COOLING AIR SIDE Energy Wheel Data Center F I L T E R Sensible & Latent Capacity Slightly Less Energy Savings Slightly Shorter Free Cooling Periods IT More $$ IT

FREE COOLING WATER SIDE Glycol/Dry-Cooler Moderate Free Cooling Periods Slightly More Fan Energy at CRAC Sensible & Latent Capacity Smaller Tonnages

FREE COOLING WATER SIDE Air Cooled Chiller Moderate Free Cooling Periods Less Fan Energy than Glycol/Dry Cooler Sensible & Latent Capacity Larger Tonnages Limited Manufacturers Available CRAC

FREE COOLING WATER SIDE With Heat Exchanger CRAC Better Free Cooling Periods Freezing of CT is Key Sensible & Latent Capacity Less Fan Energy than Glycol/Dry Cooler Larger Tonnages More Water Treatment Required

Adiabatic Cooling FREE COOLING Reduced Refrigerant Usage Combo Mode Great for Dry Climates Extends Free Cooling Period Comparable to Cooling Tower System High Water Treatment $$

ROW BASED COOLING Cooling Unit No Access Floor Required Cascade Effect Reduced Reduced Fan Energy Provides T+RH Control Redundancy Moderate Challenge Free Cooling Available w/ Chilled Water Units More Units Required VFDs Adjust Airflows to IT Loads (energy savings) IT Changes Challenging Hot Aisle Service Required In Every Row Cold Aisle

WHY CONTAINMENT?

CONTAINMENT Comes in All Different Configurations

CONTAINMENT Hot Aisle Provides Room Conditioning Provides Ride-Through Capacity During Failure IT Staff Work in Hot Zone Easier for Free Cooling Applications (hot air is captured) Cold Aisle Room is Hot Limited Ride-Through in Failure

HOT CONTAINMENT Vertical Exhaust Ducts (Chimneys) Easier to Retrofit on Legacy Data Centers Rear Cabinet Doors Must be Sealed Airflow Differential Pressure Should be Studied Same Performance as Hot Aisle Containment

FREE COOLING Pumped Refrigerant Summer Operation Outdoor Ambient 95 F KW @ 70% Load 24.1 Check Valve Condenser Solenoid Valve Refrigerant Pumps OFF Check Valve Electronic expansion valve Evaporator Circuit 2 Circuit 1 Compressors ON Check Valve

PUMPED REFRIGERANT Partial Economization Fall/Spring/Evening Operation Outdoor Ambient 65 F KW @ 70% Load 15.1 Check Valve ON Condenser Solenoid Valve OFF Refrigerant Pump Check Valve ON Electronic expansion valve Evaporator Circuit 2 Circuit 1 Compressor OFF Check Valve

PUMPED REFRIGERANT Full Economization Winter Operation Check Valve ON Condenser Outdoor Ambient 25 F KW @ 70% Load 3.7 ON Solenoid Valve Electronic expansion valve Refrigerant Pump Moderate Free Cooling Periods Less Fan & Pump Energy than Glycol/Dry Cooler & Chiller Options Sensible & Latent Capacity Evaporator Limited Manufacturers Available Circuit 2 Circuit 1 Check Valve OFF Compressor OFF Check Valve

ASHRAE CHART ASHRAE Recommended (2004) 59DP Inlet Server Conditions Allows Longer Free Cooling Hours Reduces Humidification Needs & Water Usage Improves Mechanical Equip. Efficiency ASHRAE Allowable 62.6DP 41.9DP ASHRAE Recommended (2008 TC9.9) 59 68 77 80.6 90

SUMMARY Cooling Efficiency Tips Hot Aisle Containment Free Cooling ( Air, Water, or Refrigerant) Air Delivery (don t over CFM) Chase the Cold Spots Increase Supply Air Temperatures Lower Humidity Set Points Balance Air Flows and Pressure Localized Cooling Reduces Fan Horsepower

Contact Us at info@bala.com www.bala.com