OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F



Similar documents
OVR-3SP Recloser with PCD Control Style Guide 1VAL SG March 30, 2009 Revision B

Nu-Lec Training Modules

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Application/Connection Examples

VOIP-500 Series Phone Quick Installation Guide

Table of Contents. TransformerIQ FAQs 1

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Fire Fighter Phone System Installation Instructions

TrueAlarm Fire Alarm Systems

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

User manual Compact Web PLC WP240 series IEC-line

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

8 Channel Status Input Panel model SIP-8

EQUIPMENT SPECIFICATIONS

Eaton s E-Series protective relay family

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

Advantium 2 Plus Alarm

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

T1 Backhaul Connectivity Solution All Products :: Application Note

Remote Monitoring and REC 501 Control Unit Product Guide

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Distribution Voltage Regulators

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Bypass switches. Type B-1 and type B-2. Answers for energy.

Issued E.C.S. Section WTR00 INFORMATION SECTION Page 1 of 1

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

Water Leak Detection System

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Primary and Secondary Electrical Distribution Systems

Series Six Plus Programmable Controller

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

Tmax MCCBs. Molded case circuit breakers. Tmax

Quick Connect. quick - simple - efficient.

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

A project to optimise quality and energy efficiency must include metering

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Product Specification instalert Rapid Messenger Variable Message Sign

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

PowerLogic Sub Meter Display (SMD and SMDOPN)

3500/22M Transient Data Interface

ABB RTU560A Series CMU & Modules

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

OPL BASIC. Dosing System for Professional Laundry machines. Contents

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

APPLICATION SUPPORT BULLETIN

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SHORE POWER. Safely Connecting Ships to Shore SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Power distribution in data centres

Catalog. Arc Guard System TM TVOC-2

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

DCS Input/Output Relay Card Series

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Medium Voltage Electrical Distribution

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

QR12 (1.22 ) Diameter Optical Encoder

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER

Fire Pump Controllers Remote Alarm Panels

Generation Interconnection System Impact Study Report. For. PJM Generation Interconnection Request Queue Position X1-114.

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Rack Power Distribution

Alliance System Ordering Guide

3500/93 System Display

Honeywell Analytics Lines of Business

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

maxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number Positioning Controller

Uninterruptible Power Supply

Installation instructions for Series NRX INCOM communications adapter module

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

Shunt lock function 3066

Power Supply and Cabling Options. SmartTrak 100/101/140

BB -508L/509L INSTALLATION MANUAL LATTICE BOOM CRANES. Greer Company Crane Systems. Greer Company

Chapter 9. Bonding and Grounding

Digital Keypad Use s Manual

No Phone Line II-48 System

HM-W536 Install Guide

Transcription:

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F The OVR three-phase recloser style guide aids in the proper selection of your OVR three-phase style number. The OVR recloser consists of an upper unit, cable assembly, mounting frame, accessories, and the PCD control with cabinet. The PCD control provides all the protection and metering functions required by the unit. When ordering an OVR recloser, the style number must be given to the factory. The options highlighted in gray are for a standard pole mounted recloser with basic PCD control. Typical Style Code R 1 1 5 1 Q C N 1 4 8 E 3 S 1 N 0 0 Digit 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1

OVR Three-Phase Recloser Selection Tables Table 1. Recloser Ratings Voltage (kv) BIL (kv) Continuous Current (A) Interrupting Rating (ka) Style Code Digits 1-5 15 110 630 8 R1158 15 110 630 10 R1150 15 110 630 12.5 R1151 15 110 800 12.5 R1181 15 110 1000 12.5 R1111 15 110 630 16 R1152 15 110 800 16 R1182 15 110 1000 16 R1112 27 125 630 12.5 R2251 27 125 800 12.5 R2281 27 125 1000 12.5 R2211 27 125 630 16 R2252 27 125 800 16 R2282 27 125 1000 16 R2212 38 150 630 12.5 R3551 38 150 800 12.5 R3581 38 150 1250 12.5 R3521 38 150 630 16 R3552 38 150 800 16 R3582 38 150 1250 16 R3522 38 170 630 12.5 R3751 38 170 800 12.5 R3781 38 170 1250 12.5 R3721 38 170 630 16 R3752 38 170 800 16 R3782 38 170 1250 16 R3722 Table 2. Mounting Frame Frame Description Style Code Digit 6 Pole w/ 6 Arrester Mtg bracket A Assembled 6 arresters Assembled Pole w/ 6 Arrester Mtg bracket B Unassembled 6 arresters Unassembled Pole w/ 6 Arrester Mtg & 3 PT C- Channel Mtg Bracket Assembled 6 arresters and integrated PT mounting bracket for up to (3) 150 KV C Pole w/ 6 Arrester Mtg & 3 PT C- Channel Mtg Bracket Unassembled Pole w/ 6 Arrester Mtg & Flat PT Mtg Bracket Assembled Pole w/ 6 Arrester Mtg & Flat PT Mtg Bracket Unassembled Pole w/ 6 Arrester Mtg & 6 PT Mtg Bracket, Hrztl Construction, Galvanized Assembled (15 kv / 27 kv Only) or (3) 125kV BIL single or dual bushing PTs Assembled 6 arresters and integrated PT mounting bracket for up to (3) 150 KV or (3) 125kV BIL single or dual bushing s Unassembled 6 arresters and integrated PT mounting bracket. For up to (2) single or dual bushing 150kV BIL PTs or up to (3) single bushing 125kV BIL PTs - Assembled 6 arresters and integrated PT mounting bracket. For up to (2) single or dual bushing 150kV BIL PTs or up to (3) single bushing 125kV BIL PTs - Unassembled 6 arresters and integrated PT mounting bracket for 6 PTs utilized for standard distribution line construction Assembled D H R G 2 con t on next page

Frame Description Style Code Digit 6 Pole w/ 6 Arrester Mtg & 6 PT Mtg Bracket, Hrztl Construction, Stainless Steel Assembled (15 kv / 27 kv Only) 304 SS pole mounting frame with provisions for mounting 6 arresters and integrated PT mounting bracket for 6 PTs utilized for standard distribution line construction - Assembled I Pole w/ Arrester 6 Mtg & PT 6 Mtg Bracket, Vertical Construction, Galvanized Assembled (15 kv / 27 kv Only) Pole w/ Arrester 6 Mtg & PT 6 Mtg Bracket, Vertical Construction, Stainless Steel Assembled (15 kv / 27 kv Only) Substation Frame (Fits Cooper footprint pad ) Assembled* 6 arresters and integrated PT mounting bracket for 6 PTs utilized for vertical distribution line construction - Assembled 304 SS pole mounting frame with provisions for mounting 6 arresters and integrated PT mounting bracket for 6 PTs utilized for vertical distribution line construction - Assembled Galvanized steel substation mounting frame to match Cooper recloser footprint (VTs mounted separately) Assembled Substation Frame (Fits Cooper Galvanized steel substation mounting frame to match Cooper W footprint pad ) Unassembled* recloser footprint (VTs mounted separately) Unassembled Substation Frame w/ 3 PT Mtg Galvanized steel substation mounting frame per Cooper footprint X Bracket (Fits Cooper footprint pad ) Assembled* with integrated PT mounting bracket for 3 PTs Assembled Substation Frame w/ 3 PT Mtg Galvanized steel substation mounting frame per Cooper footprint Y Bracket (Fits Cooper footprint pad ) Unassembled* with integrated PT mounting bracket for 3 PTs Unassembled None No Frame Supplied N * Note: 38 kv substation frame does not match Cooper footprint (5 inches wider). Table 3. Control Cable Length Control cable assembly actual length Description (Connectors and cable can transfer current and voltage signals, as well as power, between cabinets) 10 feet [3 m] V and I (24-Pin) 10 foot [3 m] cable assembly (Substation Standard) A 17 feet [5 m] V and I (24-Pin) 17 foot [5 m] cable assembly for voltage and current signals L 20 feet [6 m] V and I (24-Pin) 20 foot [6 m] cable assembly for voltage and current signals B 30 feet [9 m] V and I (24-Pin) 30 foot [9 m] cable assembly for voltage and current signals C 35 feet [10 m] V and I (24-Pin) 35 foot [10 m] cable assembly for voltage and current signals E 40 feet [12 m] V and I (24-Pin) 40 foot [12 m] cable assembly for voltage and current signals D Note: to mount cabinets 25 feet apart, select 30-foot cable for drip loop and spacing (add 5 feet) K M V Style Code Digit 7 3

Table 4. Cable Options for Control Power & PT Input (Digit 8 was previously a - in the style number) LV Cable Options HV Cable Options Description Style Code Digit 8 Y - - No connector provided. N Available w/voltage Sensing Y (1) 2-Pin Connector w/ 20 ft cable Control power input directly into Control Cabinet Y (1) 2-Pin Connector w/ 20 ft cable Control power directly into Control cabinet & PT voltages directly into High Voltage Cabinet Y (1) 5-Pin Connector w/ 40 ft cable Control power & LCM input when desired to bring directly into Control Cabinet Y (1) 5-Pin Connector w/ 40 ft cable and (1) 2- Pin Connector w/40 ft cable Y N Control power (2-pin) & LCM input (5-pin) directly into Control Cabinet N (1) 2-Pin Connector w/ 20 ft cable Phase PT input directly into High Voltage Cabinet for PCD & LCM & control power input directly into Control Cabinet (1) 5-Pin Connector w/ 15 ft cable (1) 5-Pin Connector w/ 15 ft cable Control power and/or phase PTs input directly into High Voltage Cabinet (2) 5-Pin Connectors w/ 15 ft cable Control power and/or phase PTs input directly into High Voltage Cabinet for PCD & LCM (2) 5-Pin Connectors w/ 15 ft cable (1) 2-pin connector with 20 ft cable utilized for control power input to low voltage cabinet where an external plug is required (1) 5- pin voltage transformer plug with 15 ft cable required to input phase voltages to the high voltage cabinet for direct connection to the PCD (3 potential transformers maximum) and (1) 2-pin power plug with 20 ft cable utilized when control power into the low voltage cabinet requires a plug (1) 5-pin voltage transformer plug with 40 ft cable for low voltage cabinet, required to put phase voltages and control power connection to pole mounted transformers for direct connection to the PCD/LCM (4 PTs maximum) Used with loop control and voltage sensing (1) 5-pin voltage transformer plugs with 40 ft cable for low voltage cabinet, required to put phase voltages and control power connection to pole mounted transformers for direct connection to the LCM (3 PTs maximum) Used with loop control and voltage sensing and includes 2 Pin power plug with 40 ft cable for control power for the PCD (1) 5-pin voltage transformer plugs with 15 ft cable for high voltage cabinet, required to put phase voltages and control power connection to the high voltage cabinet for direct connection to the PCD (3 PTs maximum) (2) 5-pin PT plugs with 15 ft cable for high voltage cabinet, required to put phase voltages and control power connection to the high voltage cabinet for direct connection to the PCD (6 potential transformers for Loop Scheme) Available only when Voltage Sensing not selected (2) 5- pin voltage transformer plugs with 15 ft cable required to input phase voltages to the high voltage cabinet for direct connection to the PCD (6 potential transformers maximum) and (1) 2-pin power plug with 20 ft cable utilized when control power into the low voltage cabinet requires a plug Available only when Voltage Sensing not selected 2 3 6 7 5 0 4 4

Table 5. Control Power Voltage & I/O (Previously Table 4, Digits 9-10) Voltage & Input / Output Contacts Description Style code Digits 9-10 15 & 27 kv ONLY 120/240 VAC (90 265 VAC / 250 VDC); No Inputs, Outputs or Alarms; Batteries 120/240 VAC (90 265 VAC / 250 VDC); 6 Inputs, 4 Outputs & Alarm; Batteries 120/240 VAC (90 265 VAC / 250 VDC Power) with no inputs, outputs, includes self-check alarm Form C contact; Recloser batteries with up to 48 hour carryover included. 12 VDC 8 W auxiliary power fused output for radio/modem (field adjustable to 24 VDC) 90 265 VAC / 250 VDC Power with 6 inputs and 4 outputs (user available), includes self-check alarm Form C contact; Recloser batteries with up to 48 hour carryover included. 12 VDC 8 W auxiliary power fused output for radio/modem (field adjustable to 24 VDC) 125 VDC; 4 Inputs, 3 Outputs & Alarm 125 VDC Power with 4 inputs and 3 outputs (user available) and self-check alarm Form C contact 125 VDC; 8 Inputs, 7 Outputs & Alarm 125 VDC Power with 8 inputs and 7 outputs (user available) and self-check alarm Form C contact 38 kv ONLY 120 / 240 VAC; No Inputs, Outputs or 120/240 VAC Power with no inputs, outputs, includes loss Alarms; Batteries of source alarm contact, Recloser batteries with up to 48 120 / 240 VAC; 6 Inputs, 4 Outputs & Alarm; Batteries hour carryover included; Includes ISD / OVR interface 85 265 VAC/VDC Power with 6 inputs and 4 outputs (user available) and includes loss of source alarm contact; Recloser batteries with up to 48 hour carryover included; Includes ISD / OVR interface 48 VDC; 4 Inputs, 3 Outputs & Alarm 48 VDC Power with 4 inputs and 3 outputs (user available) and includes loss of source alarm contact; Includes ISD / OVR interface 48 VDC; 8 Inputs, 7 Outputs & Alarm 48 VDC Power with 8 inputs and 7 outputs (user available) and includes loss of source alarm contact; Includes ISD / OVR interface 125 VDC; 4 Inputs, 3 Outputs & Alarm 125 VDC Power with 4 inputs and 3 outputs (user available) and includes loss of source alarm contact; Includes ISD / OVR interface 125 VDC; 8 Inputs, 7 Outputs & Alarm 125 VDC Power with 8 inputs and 7 outputs (user available) and includes loss of source alarm contact; Includes ISD / OVR interface 10 14 53 54 31 32 33 34 35 36 5

Table 6. Control and Faceplate Options (Previously Table 5, Digit 11) Type of Relay Description Style code Digit 11 PCD ANSI Faceplate; Excludes Firmware Options PCD ANSI Faceplate, Includes Firmware Options PCD ANSI Faceplate with Single-Phase Tripping; Excludes Firmware Options PCD ANSI Faceplate with Single-Phase Tripping; Includes Firmware Options PCD IEC Faceplate; Excludes Firmware Options PCD IEC Faceplate; Includes Firmware Options PCD IEC Faceplate with Single-Phase Tripping; Excludes Firmware Options PCD IEC faceplate with Single-Phase Tripping; Includes Firmware Options PCD with ANSI faceplate, red close and green trip button, front RS-232 port, large view LCD, integral tagging function; Excludes load profile, oscillography, power quality and programmable curve software PCD with ANSI faceplate, red close and green trip button, front RS-232 port large view LCD, integral tagging function; Includes load profile, oscillography, power quality and programmable curve software PCD with ANSI faceplate, red close and green trip button, front RS-232 port, large view LCD, integral tagging function; Single-phase tripping; Excludes load profile, oscillography, power quality and programmable curve software PCD with ANSI faceplate, red close and green trip button front RS-232 port, large view LCD, integral tagging function; Single-phase tripping; Includes load profile, oscillography, power quality, and programmable curve software PCD with IEC faceplate, green close button and red trip button; Excludes load profile, oscillography, power quality and programmable curve software PCD with IEC faceplate, green close button and red trip button; Includes load profile, oscillography, power quality and programmable curve software PCD with IEC faceplate, green close button and red trip button; Single-phase tripping; Excludes load profile, oscillography, power quality and programmable curve software PCD with IEC faceplate, green close button and red trip button; Single-phase tripping; Includes load profile, oscillography, power quality, and programmable curve software Table 7. Voltage Sensing & Pickup Settings (Field Adjustable) (Previously Table 6, Digit 12) Pickup Setting Ground Pickup Setting Phase No Sensitive Earth Fault Style Code Digit 12 Includes SEF Style Code Digit 12 External PT Voltage Sensing (120 VAC input) 10-160 A 20-320 A A B 10-160 A 100-1600 A X Y 50-800 A 20-320 A C D 50-800 A 100-1600 A E F Internal Voltage Sensing SEF Included 10-160 A 20-320 A See Note H 10-160 A 100-1600 A See Note K 50-800 A 20-320 A See Note M 50-800 A 100-1600 A See Note Q Note: The pickup setting may be field adjusted to the low or high range via jumpers on the PT/CT input circuit board Sensitive Earth Fault is now a standard feature. Use of Non-SEF is for only recommend for existing customers. E 3 F 1 D 9 C 7 6

Table 8. Communication Ports and Protocol (Previously Table 7, Digit 13) Communication Description Ports No Communication Includes one non-isolated RS-232 port (on CPU) only for externally isolated Module SCADA communication and local programming RS-232 port (nonisolated, on CPU) Com2a Module RS-232 (isolated) RS-485 (isolated) Fiber (star connected only) Com5 Module (Loop Control Ready) RS-232 (isolated) RS-485 (isolated) Com5 Module (w/ Loop Control Module) RS-232 (isolated) RS-485 (isolated) One isolated RS-232, RS-485 and Fiber Optic Port for SCADA communication and control programming. All ports are radial connected (one at a time), with selection of port set by jumpers on module One isolated RS-232 and RS-485 Port for SCADA communication and control programming. All ports are radial connected (one at a time), with selection of port using jumpers on module. One isolated RS-232 and RS-485 Port for SCADA communication and control programming. All ports are radial connected (one at a time), with selection of port using jumpers on module. (Includes processor for loop control and Loop Control Interface Module - LCM) Style code Digit 13 0 Note: All PCDs are supplied with DNP 3.0, MODBUS TM RTU and MODBUS TM ASCII protocols. All units have two independent communications ports. The front port is a 9 pin RS-232 port that supports MODBUS ASCII only and the rear port(s) supports all protocols. All units are Loop Control Ready. Table 9. Bushing Terminal Connectors (Previously Table 8, Digit 14) Connector Description Style code Digit 14 Stud terminal Threaded stud is 1 12 thread S NEMA 2-Hole Pad NEMA 2-hole pad (6 included) 2 NEMA 4-Hole Pad NEMA 4-hole pad (6 included) 4 Clamp Clamp type connector (#6-800 MCM) (6 included) C Note: Stud is 1 12 thread Table 10. Heater Preset Voltage (Field Adjustable to 120 or 240 VAC) (Previously Table 9, Digit 15) Preset Voltage Description Style code Digit 15 120 VAC 120 VAC Heater in both cabinets (Field Adjustable to 240 VAC) 1 240 VAC 240 VAC Heater in both cabinets (Field Adjustable to 120 VAC) 2 Table 11. Standard Dynamic Accessories (Digit 16 Previously a - in the style number) Accessories Description Style code Digit 16 None No accessories required N 69 Switch Block close function from yellow handle A (Not available with (2) 5-pin option. Not available with (1) 5-pin option and voltage sensing. Requires selection of inputs and outputs from table 5) Transfer Switch (83) Transfer switch to transfer control power from primary to secondary source B (PTs must be available on line and load side ) Potential Test Switch Potential test switch C Current Test Switch Current test switch D Current & Potential (1) Potential test switch & (1) Current test switch E Test Switches Note: If more than one feature is required, choose other feature(s) from the table 12 2 5 6 Style Code Digit 17-18 00 for Standard Style numbering will change for specials & dynamic accessories 7

Table 12. Dynamic Accessories Specific to unit, will change last four digits of style number (Previously Table 10, Digits 17 18) Accessories Description Radio Package Radio package 69 Switch Block close function from yellow handle (not available with (2) 5-pin option or single 5 pin option in high voltage cabinet with voltage sensing Transfer Switch Transfer switch to transfer from primary to secondary source (PTs must be available on both sides, (2) 5-pin connectors should be selected) or 5 pin connector in LV cabinet should be selected Potential Test Switch Potential test switch Current Test Switch Current test switch Current & Potential Test (1) Potential test switch & (1) Current test switch Switches Wiring for 1 Potential Wiring and mounting for (1) PT on assembled recloser frame (PT not Transformer included) Wiring for 3 Potential Wiring and mounting for (3) PTs on assembled recloser frame (PT not Transformers included) Wiring for 6 Potential Wiring and mounting for (6) PTs on assembled recloser frame (PT not Transformers included) Wiring for 4 Potential Wiring and mounting for (4) PTs on assembled recloser frame (PT not Transformers included) Note: Mounting and wiring of PTs requires assembled frame Table 13. Static Accessories Not specific to a unit, will be ordered as a separate line item Style Accessories Description Number 12A00481G02 Cable Locking Sleeve Tamper resistant cable locking sleeve 24-pin connector 12A00482G02 Cable Locking Sleeve Tamper resistant cable locking sleeve 2-pin connector or 5-pin connector in LV unit 1B009360H01 15 kv / 27 kv Animal Guard (Straight) Animal guard (straight shape, order 3 or 6 respectively) (15-27 kv only) 1B009380H01 38kV Animal Guard (Straight) Animal guard (straight shape, order 3 or 6 respectively) (38 kv only) 1B009356H07 Cable Animal Guard with Straight pins 36 long 1 diameter cable maximum for installing on noninsulated cable normally used with animal guards listed above, order 3 or 6 respectively 1B009356H10 PT Animal Guard Animal guard for PT connection ( order 1 for each single bushing PT and 2 for each 2 bushing PT) 1B009360H02 Animal Guard (L Shaped) Animal guard (L-shape, order 3 or 6 respectively) (15-27 kv only) ABB Inc. 655 Century Point Lake Mary, Florida 32746 Ph: 1-800-929-7947 or +1-407-732-2000 www.abb.com/mediumvoltage 1VAL264001-SG Rev. F October 2009 8