3500/22M Transient Data Interface
|
|
|
- Domenic Perry
- 10 years ago
- Views:
Transcription
1 3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery management software. The TDI combines the capability of a 3500/20 Rack Interface Module (RIM) with the data collection capability of a communication processor such as TDXnet. The TDI operates in the RIM slot of a 3500 rack in conjunction with the M series monitors (3500/40M, 3500/42M, etc.) to continuously collect steady state and transient waveform data and pass this data through an Ethernet link to the host software. (Refer to the Compatibility section at the end of this document.) Static data capture is standard with the TDI, however using an optional Channel Enabling Disk will allow the TDI to capture dynamic or transient data as well. The TDI features improvements in several areas over previous communication processors and incorporates the Communication Processor function within the 3500 rack. Although the TDI provides certain functions common to the entire rack it is not part of the critical monitoring path and has no effect on the proper, normal operation of the overall monitor system. Every 3500 rack requires one TDI or RIM, which always occupies Slot 1 (next to the power supplies). For Triple Modular Redundant (TMR) applications, the 3500 System requires a TMR version of the TDI. In addition to all the standard TDI functions, the TMR TDI also performs monitor channel comparison. The 3500 TMR configuration executes monitor voting using the setup specified in the monitor options. Using this method, the TMR TDI continually compares the outputs from three (3) redundant monitors. If the TDI detects that the information from one of those monitors is no longer equivalent (within a configured percent) to that of the other two monitors, it will flag the monitor as being in error and place an event in the System Event List. C US Page 1 of 9
2 Specifications Inputs Power Consumption Data Front panel: 10Base-T / 100Base-TX I/O: 100Base-FX I/O: Outputs Front Panel LEDs OK LED: TX/RX LED: TM LED: CONFIG OK LED: I/O Module OK Relay: 10.5 Watts kbaud maximum RS232 serial communications 10Base-T or 100Base-TX Ethernet, autosensing 100Base-FX Fiber-Optic Ethernet Indicates when the 3500/22M is operating properly Indicates when the 3500/22M is communicating with the other modules in the rack. Indicates when the 3500 rack is in Trip Multiply mode. Indicates that the 3500 rack has a valid configuration. Relay to indicate when the 3500 rack is operating normally or when a fault has been detected within the rack. User can select either an OPEN or CLOSED contact to annunciate a NOT OK condition. This relay always operates as Normally Energized. OK Relay: Normally closed contacts: Controls Front Panel Rack reset button: Address switch: Configuration Keylock: I/O Module System Contacts Trip Multiply: Description: Rated to 24 Vdc/120 Vac, 120 Watts/600 VA Switched Power. Arc suppressors are provided. Clears latched alarms and Timed OK Channel Defeat in the rack. Performs same function as Rack Reset contact on I/O module. Used to set the rack address: 127 possible addresses. Used to place 3500 rack in either RUN mode or PROGRAM mode. RUN mode allows for normal operation of the rack and locks out configuration changes. PROGAM mode allows for normal operation of the rack and also allows for local or remote rack configuration. The key can be removed from the rack in either position, allowing the switch to remain in either the RUN or PROGRAM position. Locking the switch in the RUN position allows you to restrict unauthorized rack reconfiguration. Locking the switch in PROGRAM position allows remote reconfiguration of a rack at any time. Used to place 3500 rack in Trip Multiply. Page 2 of 9
3 Maximum Current: Alarm Inhibit: <1 madc, Dry Contact to Common Initiation of transient data collection based on detecting the machine speed within one of two programmable windows. Description: Maximum Current: Used to inhibit all alarms in the 3500 rack. <1 madc, Dry Contact to Common Alarm Data Collection The number of transient events that can be collected is only limited by the available memory in the module. Rack Reset: Pre- and post-alarm data. Description: Maximum Current: Data Collection Keyphasor* Inputs: Number of Channels Used to clear latched alarms and Timed OK Channel Defeat. <1 madc, Dry Contact to Common Supports the four 3500 system Keyphasor signals. The speed range support is based on the number of dynamic channels enabled: Minimum Speed Maximum Speed 1 to 16 1 rpm 100,000 rpm 17 to 24 1 rpm 60,000 rpm 25 to 48 1 rpm 30,000 rpm Startup / Coastdown Data Supports multiple events per revolution speed inputs up to 20 khz. Data collected from speed and time intervals. Increasing and decreasing speed interval independently programmable. Static Values Data Waveform Sampling 1 second of static values collected for 10 minutes before the event and 1 minute after the event. 100 ms static values collected for 20 seconds before the event and 10 seconds after the event. 2.5 minutes of waveform data at 10-second intervals before the alarm and 1 minute collected at 10- second intervals after the alarm. TDI will collect the static values including the values measured by the monitors. TDI provides four nx static values for each point. Amplitude and phase are returned for each of the values. Collection of waveforms for 48 channels. DC-coupled waveforms. Simultaneous Synchronous and Asynchronous data sampled during all operational modes User-configurable Synchronous waveform sampling rates: Page 3 of 9
4 samples/rev for samples/rev for samples/rev for samples/rev for samples/rev for samples/rev for samples/rev for samples/rev fro 64 and - 16 samples/rev for 128 revolutions. Asynchronous data sampled to support an 800-line spectrum at the following frequency spans: - 10 Hz, - 20 Hz, - 50 Hz, Hz, Hz, Hz, Hz, Hz, Hz, - 10 khz, - 20 khz, and - 30 khz. Asynchronous data is antialias filtered. Channel Pairs for providing Orbit or synchronous full spectrum presentations can be split among multiple monitors. For asynchronous Communications Protocols BN Host Protocol: BN TDI Protocol: Front Panel Communications: Protocol Supported: Baud Rate: Cable Length: Connector: 10Base-T / 100Base-TX Ethernet I/O Communications: Protocol Supported: full spectrums the channels must be within a monitor channel pair (30 khz frequency span data will not be phase correlated between channel pairs). Communication with 3500 Configuration Software, 3500 Data Acquisition Software, and 3500 Display Software. Communication with GE s System 1* Asset Management and Data Collection Software. RS232 BN Host Protocol kbaud maximum (autobaud capable) USB Cable Length: 5 meters (16.4 ft) maximum. A 3 meter (9.8 ft) cable is included with the 3500 rack. USB-B Ethernet, 10Base-T and 100Base-TX. Conforms to IEEE Page 4 of 9
5 BN Host Protocol and BN TDI Protocol using Ethernet TCP/IP. Operating Temperature: Connection: -30 C to +65 C (-22 F to +149 F) RJ-45 (telephone jack style) for 10Base-T/100Base-TX Ethernet cabling. Cable Length: 100 metres (328 feet) maximum. 100 Base-FX Ethernet I/O Communications: Ethernet, 100Base-FX Fiber Optic, full duplex multimode. Conforms to IEEE802.3u. Storage Temperature: Humidity: Battery Life Powered TDI: Un-powered TDI: -40 C to +85 C (-40 F to +185 F) 95%, non-condensing C (122 F) C (122 F) Protocol Supported: Connection: BN Host Protocol and BN TDI Protocol using Ethernet TCP/IP. MT-RJ Male Fiber Optic connector for 100 Base-FX cabling. Compliance and Certifications EMC Standards: EN Immunity for Industrial Environments EN 55011/CISPR 11 ISM Equipment EN Emissions for Industrial Environments Cable Length: 2000 metres (6560 feet) maximum, multimode fiber optic cable. Note The 3500/22M has a MT-RJ Male connector on the unit for Fiber Optic 100 Base-FX cabling therefore you MUST use a MT-RJ Female connector on the fiber optic cable to ensure proper connectivity. Environmental Limits TDI Module, 10Base-T / 100Base-TX I/O, and 100Base-FX I/O European Community Directives: EMC Directive 2004/108/EC Electrical Safety Standards: EN European Community Directives: 2006/95/EC Low Voltage Hazardous Area Approvals North American Approval Option (01) Class 1, Div 2 Groups A, B, C, D Ta = -20 C to +65 ºC Page 5 of 9
6 (-4 ºF to +150 ºF) (-4 ºF to +150 ºF) Note: When used with Internal Barrier I/O Module, refer to specification sheet for approvals information. North American Approval Option (02) Ex nc[l] IIC Class 1, Zone 2 For further certification and approvals information please visit the following website: Physical TDI Module Class 1, Div 2, Groups A, B, C, D Ta -20 C to +65 ºC (-4 ºF to +150 ºF) Dimensions (Height x Width x Depth) mm x 24.4 mm x mm (9.50 in x 0.96 in x 9.52 in). ATEX: Weight Approval Option (02) 0.91 kg (2.0 lbs). Brazil Approval Option (02) South Africa Approval Option (02) For Selected Ordering Options with ATEX/North American agency approvals: II 3/(3) G Ex nc[l] IIC Ta = -20 C to +65 ºC (-4 ºF to +150 ºF) For Selected Ordering Options with ATEX/North American agency approvals: BR-Ex nc [nl] IIC T4 Ta = -20 C to +65 ºC (-4 ºF to +150 ºF) For Selected Ordering Options with ATEX/North American agency approvals: Ex ncal [ia] IIC T4 Ex ncal [L] IIC T4 Ta = -20 C to +65 ºC I/O Modules Dimensions (Height x Width x Depth) Weight Rack Space Requirements TDI Module I/O Modules mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in) kg (0.44 lbs). 1 full-height front slot. 1 full-height rear slot Ordering Information List of Options and Part Numbers 3500/22M TDI Module and I/O 3500/22-AXX-BXX-CXX A: Transient Data Interface Type 0 1 Standard (Use for standard monitoring applications) 0 2 TMR (Use only for applications that require a Triple Modular Redundant Configuration). B: I/O Module Type Base-T/100Base-TX Ethernet I/O module Page 6 of 9
7 Base-FX (Fiber Optic) Ethernet I/O module C: Agency Approval Option 0 0 None 0 1 CSA/NRTL/C 0 2 CSA/ATEX 100 Base-FX Fiber Optic Cable with MT-RJ Female connectors AXXX A: Length (in ft.) up to 1300 ft (400 m) in length: 10 ft. 500 ft. in 10 ft. increments only 500 ft ft. in 100 ft. increments only 3500/22M Dynamic Data Enabling Disk This disk enables the number of channels of dynamic data (i.e., the ability to collect waveforms) that the TDI will support. There are two levels of dynamic data. Steady-State points are channels that collect waveform data due either to a software command or to an alarm event, and therefore support current values, scheduled waveform capture, and alarm data capture. Transient points provide all the function of a Steady-State point with the additional capability of waveform collection due to parameter variations such as machine speed. 3500/09-AXXX-BXXX A: Steady-State Points: 0 to 672 B: Transient Points: 0 to 672 Note: The sum of the two fields must be equal to or less than 672. One disk can support multiple TDIs. Ethernet Cables: Standard 10 Base-T/100 Base-TX Shielded Category 5 Cable with RJ-45 connectors (solid conductor) AXXX A: Cable Length: feet (1.8 m) feet (3.0 m) feet (7.6 m) feet (12.2 m) feet (15.2 m) feet (22.9 m) feet (25.9 m) feet (30.5 m) feet (36.6 m) feet (45.7 m) feet (61.0 m) feet (76.2 m) feet (97.5 m) Note: Standard lengths for 10Base-T/100 Base-TX cabling are shown above. Spares M Standard Transient Data Interface Module with USB cable TMR Transient Data Interface Module with USB cable 10 foot A to B USB cable 10Base-T/100Base-TX I/O Module 100Base-FX (Fiber Optic) I/O Module 3500 Buffered Signal Output Module 3500/22M TDI Operation and Maintenance Manual Network Accessories Datasheet Connector header, internal termination, 3-position, green Connector header, internal termination, 6-position, green Page 7 of 9
8 Graphs and Figures Figure 1: Front and rear view of the Transient Data Interface 1 Main module 2 10 Base-T/100 Base-TX Ethernet I/O module Base-FX Ethernet I/O module 4 LEDs: Indicates the operating status of the module 5 Hardware switches 6 Configuration port: Configure or retrieve machinery data using USB 7 OK relay: Indicates the OK status of the rack 8 Fiber optic Ethernet port: For configuration and data collection 9 RJ-45 Ethernet port: For configuration and data collection 10 System contacts Page 8 of 9
9 Compatibility When upgrading your 3500 rack from a 3500/20 RIM to a 3500/22 TDI, there may be 3500 M modules (e.g. 3500/40M) that are not compatible with the 3500/22. Please check with [email protected] for additional details. * Denotes a trademark of Bently Nevada, Inc., a wholly owned subsidiary of General Electric Company Bently Nevada, Inc. All rights reserved. Printed in USA. Uncontrolled when transmitted electronically Bently Parkway South, Minden, Nevada USA Phone: Fax: Page 9 of 9
3500/15 Power Supply Bently Nevada* Asset Condition Monitoring
3500/15 Power Supply Bently Nevada* Asset Condition Monitoring Description The 3500 Power Supplies are half-height modules and must be installed in the specially designed slots on the left side of the
3500/25 Enhanced Keyphasor*Module
3500/25 Enhanced Keyphasor*Module Bently Nevada* Asset Condition Monitoring Description The 3500/25 Enhanced Keyphasor Module is a half-height, two-channel module used to provide Keyphasor signals to the
3500/93 System Display
3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide
3500/40M Proximitor* Monitor
3500/40M Proximitor* Monitor Bently Nevada* Asset Condition Monitoring Description The 3500/40M Proximitor Monitor is a 4-channel monitor that accepts input from Bently Nevada proximity transducers, conditions
1701/22 FieldMonitor Management Interface Module
1701/22 FieldMonitor Management Interface Module Bently Nevada Asset Condition Monitoring Description The 1701/22 FieldMonitor Management Interface Module (FMIM) is a highlyintegrated module that provides
3500/62 Process Variable Monitor
3500/62 Process Variable Monitor Description The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters (pressures, flows, temperatures, levels, etc.) that merit
TrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
Part Number 129777-01 Revision A, January 1996. 3500 Monitoring System Rack Configuration and Utilities Guide
Part Number 129777-01 Revision A, January 1996 3500 Monitoring System Rack Configuration and Utilities Guide Copyright 1995 Bently Nevada Corporation All Rights Reserved. No part of this publication may
Cisco 7816-I5 Media Convergence Server
Cisco 7816-I5 Media Convergence Server Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks, enabling easy collaboration every time from
XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment
XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment Part of the device networking family of networkenablement products, XPress-Pro SW series
350500 Dynamic Pressure Charge Amplifier
350500 Dynamic Pressure Charge Amplifier Bently Nevada* Asset Condition Moniting Description The 350500 Dynamic Pressure Charge Amplifier (DPCA) is a component in a dynamic pressure sensing system. This
Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring Description The standard 330400 Accelerometer has a limited temperature range it can be exposed to, due to its signal
2-Pair. Managed SHDSL Ethernet Extender. User s Manual
2-Pair User s Manual 1. Quick Start Guide This quick start guide describes how to install and use the Managed SHDSL Ethernet Extender. This is the Ethernet Extender of choice to extend 10/100 Ethernet
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Foxboro Evo Process Automation System
Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module
G-TAP A Series // Data Sheet
Product The GigaTAP A Series is a line of network TAPs designed with the Gigamon Always On architecture. This one-of-a-kind architecture eliminates network link downtime on network connections through
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
User Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents
ORION TELECOM NETWORKS INC. T1
RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. T1 Protection (Fail-Over) Switch Product Brochure & Data Sheet Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. 20100, N 51st Ave, Suite B240,
Provides one channel for Ethernet over existing
LB304A LBPS301A LBPS304A Hardened Ethernet Extender Quick Start Guide Provides one channel for Ethernet over existing voice-grade copper twisted-pair wire. copper BLACK wire. BOX Customer Support Information
TX2123 RS485 TO ETHERNET ADAPTOR
TX2123 RS485 TO ETHERNET ADAPTOR Converts Datacomms between fibre optic Modbus TCP over Ethernet and hard-wired copper Modbus RTU over RS485 Fibre Optic MODBUS TCP/ IP Ethernet Copper MODBUS RTU RS485
ProCurve Switch 8000m (J4110A) and Switch 8000m
ProCurve Switch 4000m and Switch 8000m The ProCurve Switch 4000m and 8000m are managed modular 10/100/1000 desktop switches that provide scalable, expandable, low-cost migration to 10/100 switching for
Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem
Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem The Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem provides EuroDOCSIS broadband network operators with a cost-effective solution for delivering standardsbased,
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
L5354 ControlNet Communications Interface
L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or
Provides one channel for Ethernet over existing
LB304A LBPS301A LBPS304A Hardened Ethernet Extender Quick Start Guide Provides one channel for Ethernet over existing voice-grade copper twisted-pair wire. copper BLACK wire. BOX Customer Support Information
Uninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
T200, PTP/IEEE 1588 Grandmaster Clock and
T200, PTP/IEEE 1588 Grandmaster Clock and NTP Time Server with high accuracy GPS receiver, OCXO or Rubidium oscillator 1 Bd d Armor 22300 LANNION - FRANCE [email protected] 1 HEOL-T200 : PERFORMANCE
sat-nms SMU Signal Management Unit
sat-nms SMU Signal Management Unit Application Note 2014, SatService GmbH www.satnms.com SMU-APP-1408-1 1/37 1 System Description and Configuration of sat-nms SMU The sat-nms SMU is the unit you were always
Ethernet. Customer Provided Equipment Configuring the Ethernet port.
Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.
OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL
OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-NMS Rev. X1 E-Mail: [email protected] www.olsontech.com
Long Range Ethernet Extender
Long Range Ethernet Extender Model Number: EIDM-EXTEND-2 User s Manual Rev. 1.0 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road Ottawa, IL 61350 USA Phone: (815) 433-5100 General
GEU-0822 8-Port Gigabit Switch
GEU-0822 8-Port Gigabit Switch 1 V1. 1_20150622 1. INTRODUCTION... 3 1.1 Product Briefs... 3 1.2 Product Features... 3 1.3 Hardware Introduction... 4 2. CONNECTING THE SWITCH... 5 2.1 Package Contents...
Cisco MCS 7816-I3 Unified Communications Manager Appliance
Cisco MCS 7816-I3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables
Description. Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers
Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers R Description These accelerometers are intended for critical machinery applications where casing acceleration
330505 Low Frequency Velocity Sensor
330505 Low Frequency Velocity Sensor Bently Nevada* Asset Condition Monitoring Description The Bently Nevada Low Frequency Velocity Sensor is designed to measure absolute (relative to free space) bearing
Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.
Proud Partners with MOBATime GPS or DCF 77 MOBA-NMS (Network Management Sy The new multipurpose time server for the LAN and NTP-based Distributed Time System by MOBATIME DTS 4138.timeserver The DTS 4138.timeserver
200350 and 200355 Accelerometers
and Accelerometers Bently Nevada Asset Condition Monitoring Description The and Accelerometers are general purpose, casemounted seismic transducers designed for use with Trendmaster Pro Constant Current
Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2)
Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2) Legal notice: Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
MICROSENS Media Converter 10/100/1000T to Gigabit Fiber
MICROSENS Media Converter 10/100/1000T to Gigabit Fiber User Guide 10/100/100 TX to Gigabit Fiber Media Converter Page 2/7 Package Contents Please refer to the package content list below to verify them
USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)
USER MANUAL MODEL 2300M SERIES OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M) An ISO-9001 Certified Company Part# 07M2300M Doc# 077321U Rev. A Revised 4/14/03 SALES OFFICE (301) 975-1000
DCS Data and communication server
8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With
Unidirectional Transmitter/ Receiver Units Introduction
Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created
Cisco MCS 7825-H3 Unified Communications Manager Appliance
Cisco MCS 7825-H3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s
TECHNICAL SPECIFICATIONS zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s 2015 LitePoint, A Teradyne Company. All rights reserved. The LitePoint zseries 18-slot chassis is an
8 Port Gigabit 10M/100M/1000M Fast Ethernet Switch. User Manual
8 Port Gigabit 10M/100M/1000M Fast Ethernet Switch User Manual Part#: PL-1008G V0613 Package Contents: The following items should be found in your package: 8 Port Desk-top Giga Ethernet Switch Power Adapter
Overview of Cisco 2600 Series Routers
CHAPTER 1 Cisco 2600 series routers are modular access routers with LAN and WAN connections that can be configured by means of interchangeable modules and WAN interface cards. This guide discusses the
IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction
IES-3080/3062 Series Features Industrial 8-port managed Ethernet switch Fastest Redundant Ethernet Ring: O-Ring (recovery time < 10ms over 250 units of connection) Open-Ring supports the other vendor s
FlexDSL MiniFlex. SHDSL.bis Up to 30Mbps Ddd. Ethernet. Features. Possible Applications
SHDSL.bis Up to 30Mbps Ddd Ethernet FlexDSL MiniFlex Features Up to 15Mbps Data Transmission per Copper Pair SHDSL and SHDSL.bis, TC-PAM16/32 Additional TC-PAM4/8/64/128 Available 1 or 2 Copper Pairs Support
NetScanner System. Toronto: 416 754 7008, Montreal: 514 695 5147, Toll Free:1888 754 7008, Email: [email protected]; www.a-tech.ca
Networking Solutions NetScanner System 9IFC/90DB/90DC FEATURES Ethernet Interface for NetScanner System Modules Provides Power and Hardware Trigger Interface 10/100 Base-T Auto-Negotiating Universal AC
Indoor / Outdoor Antenna
z300 High Precision NTP Time Server Indoor / Outdoor Antenna High Precision NTP Time Server with PoE (Indoor or Outdoor use) synchronized by GPS Revision 4 ZTI / 1 boulevard d'armor / BP 20254 / 22302
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
Product Specifications
Cisco Model EPR2320 EuroDOCSIS 2.0 Residential Gateway with Wireless Access Point The Cisco Model EPR2320 EuroDOCSIS 2.0 Residential Gateway (EPR2320) combines a cable modem, router, and wireless access
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual
D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch Manual TABLE OF CONTENTS About This Guide... 1 PURPOSE...1 TERMS/USAGE...1 OVERVIEW OF THIS USER S GUIDE...1 Introduction... 2 FAST ETHERNET TECHNOLOGY...2
VALIANT COMMUNICATIONS
VALIANT COMMUNICATIONS VCL-XC 64 Port Electronic Intelligent Patch Panel E1 to E1 Patch Panel Product Brochure & Data Sheet U.K. Valiant Communications (UK) Ltd 1, Acton Hill Mews, 310-328 Uxbridge Road,
ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000
ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 I. General A. Summary The monitoring system shall be an expandable, self-contained microprocessor-controlled IMS-4000 Host unit (hereafter referred to as
USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A
USER S MANUAL Ethernet 10/100 Transceiver Series DL221/DL221A June 1999 ETHERNET 10/100 TRANSCEIVER INSTRUCTION MANUAL SERIES DL221/DL221A INTRODUCTION Thank you for purchasing the Radiant Communications
DeltaV SISnet Repeater
September 2013 Page 1 The DeltaV SIS platform is the world s smart SIS system to use the power of predictive intelligence for increasing the availability of the entire safety instrumented function. Fiber-optic
DeltaV Control Network Hardware
DeltaV Distributed Control System Product Data Sheet October 2014 DeltaV Control Network Hardware The DeltaV Control Network is easy to install and maintain with the new DeltaV Smart Switches Easy to use
Chassis, Power Supply, and Element Management
Chassis, Power Supply, and Element Management C-COR CHP Max5000 Converged Headend Platform Accelerate deployment of new, revenue generating advanced services Innovative technology creating converged high-
Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System
Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System MODEL NUMBER: HTR05-1U Description Tripp Lite's HTR05-1U AVR Series intelligent, Automatic Voltage Regulated
FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems
Data Sheet FOMi-E3, FOMi-T3 Extend the range of E3, T3 or HSSI services over fiber optic cables up to 110 km (68 miles) Transparently transmit E3, T3 or HSSI signals over multimode and single-mode fiber
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
Product Data. Thermal Comfort Data Logger Type 1221. Including Application Software Type 7301
Product Data Thermal Comfort Data Logger Type 1221 Including Application Software Type 7301 USES: For measuring all physical parameters necessary to evaluate heat stress and thermal comfort For evaluating
Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors
Product Description You need to protect the equipment in your data center, computer room, or equipment room from the damaging effects of high temperature and high humidity. The best way to protect sensitive
MDI/MDIX) FEP-32008T-3
TM Mico-Switch/8 8 Port 10/100Base-TX Switch (Auto MDI/MDIX) FEP-32008T-3 U SER S M ANUAL (Auto MDI/MDIX) FEP-32008T-3 TM TM Package Contents Package contents include the following: Micro-Switch/8; 8 Port
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
Wireless I/O Card. Wireless I/O Card. Introduction. DeltaV Product Data Sheet
October 2014 Page 1 Redundant (WIOC) Fully redundant Wireless solution from to the Smart Wireless Field Link Optional simplex for smaller applications Seamless integration with DeltaV system and AMS Suite.
SECTION 13421 PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL. 1.01 Summary. A. Section Includes:
SECTION 13421 PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL 1.01 Summary A. Section Includes: 1. The ISS shall furnish all labor, materials, equipment, services and incidentals
User Guide TL-SG1016/ TL-SG1024 16/24-port Gigabit Ethernet Switch
User Guide TL-SG1016/ TL-SG1024 16/24-port Gigabit Ethernet Switch Rev:2.0.0 7106500823 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
palm Switch 500 5 Port 10/100 Base-TX Switch with Auto MDI/MDI-X User Guide
palm Switch 500 5 Port 10/100 Base-TX Switch with Auto MDI/MDI-X User Guide Rev. 1.0 June, 2003 User Guide 1. Introduction Welcome to the World of Mini-Networking. In the modern business society, communication
HP ProCurve Switch 1800 Series Overview. HP ProCurve Switch 1800-24G. HP ProCurve Switch 1800-24G. HP ProCurve Switch 1800-8G
Overview HP ProCurve Switch 1800-24G HP ProCurve Switch 1800-8G Models HP ProCurve Switch 1800-8G HP ProCurve Switch 1800-24G J9029A J9028B Key features Web-managed Layer 2 Gigabit switch 8- and 24-port
Velomitor Piezo-velocity Sensor
Specifications and Ordering Information Velomitor Piezo-velocity Sensor BENTLY NEVADA MADE IN U.S.A. VELOMITO PN 330500 100 mv/in/s (4 mv/mm/s) Description Velomitor Piezo-velocity Sensors measure absolute
Series Six Plus Programmable Controller
Series Six Plus Programmable Controller Gl?K-0147B June 1989 Central Processor Unit 8-Slot Rack 1l-Slot Rack General Description The Central Processor Unit (CPU) for the Series Six Plus Programmable Logic
Galleon 6-10K Online UPS. Voltronic Power Technology Corporation
Galleon 6-10K Online UPS Voltronic Power Technology Corporation Features Galleon online UPS series delivers optimal power quality, provides superior power management, resolves utility power protection
Temperature Alert. LAN-based Temperature and Humidity Data Logger
Temperature Alert LAN-based Temperature and Humidity Data Logger LAN-based Temperature and Humidity Monitoring - Supports Simultaneous WiFi and Hardwired Interfaces -20 C to +60 C (-4 F to +140 F) Standard
Industrial Bar Code Scanners
DX8200A Industrial Bar Code Scanners Configuration SW Tool ACR4 technology PackTrack ASTRA technology APPLICATIONS Postal/Courier parcel sorting and tracking Automated warehousing identification systems
MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card
Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully
SECTION 16911 WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM
WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM PART 1 GENERAL 01 02 03 04 SCOPE This section describes the metering, communications, and visualization requirements for a modular, scalable Web-based Power
Emerson Smart Firewall
DeltaV TM Distributed Control System Product Data Sheet Emerson Smart Firewall The Emerson Smart Firewall protects the DeltaV system with an easy to use perimeter defense solution. Purpose built for easy
VIBROCONTROL 4000. Sensitive Machine Monitoring
VIBROCONTROL 4000 Sensitive Machine Monitoring Reliable Machine Protection with VIBROCONTROL 4000 Brüel & Kjaer Vibro has for many years been one of the leading manufacturers of machine protection systems.
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
M-series MD Plus Controller
August 2013 Page 1 The DeltaV MD Plus Controller and the DeltaV I/O subsystem make rapid installation easy. Increases productivity Easy to use Has the flexibility to meet your needs Introduction The MD
Cisco Nexus 7000 Series Power Supply Modules
Cisco Nexus 7000 Series Power Supply Modules Product Overview The Cisco Nexus 7000 Series Power Supply Modules (Figures 1 and 2) deliver fault tolerance, high efficiency, load sharing, and hot-swappable
ProCurve Switch 1400 Series
The ProCurve Switch 1400 series provides plug-and-play simplicity for high-bandwidth connectivity. The Switch 1400 series consists of two unmanaged switches. The ProCurve Switch 1400-24G is a 24-port 10/100/1000
VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer
VCL-MX Version 6 - T 20Mbps Voice & Data Multiplexer VCL-MX Version 6 DXC 80 T, 20Mbps Digital Access Cross Connect Switch System Guide Copyright: Valiant Communications Limited - 202 Warranty This Valiant
HARTING mcon 1000 Introduction and features
Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)
INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description
INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS stam-irs_en 01/11 STAM-IRS is a dedicated server to be used with the STAM-2 monitoring station which enables receiving transmissions sent via telephone
HP V1410 Switch Series. Product overview. Key features. Data sheet
Data sheet Product overview HP V1410 series switches are unmanaged Gigabit Ethernet and Fast Ethernet switches designed for small businesses looking for entry-level, low-cost networking solutions with
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
ALARMS-xx. Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL
Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL User s Guide Version 1.0 07/01/2009 Michael Stevens & Partners Ltd. has made
