12,5. Ordering data. Illuminance (factory default) 2

Similar documents
basicdim DGC Compact control module

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

Operating instructions IV / 2007

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

Operating instructions II / 2004

Busch-Watchdog Presence EIB Type:

LED Driver Compact dimming. Udriver LCAI 35W 350mA 900mA ECO C ECO series

EBDSPIR-DD, EBDSPIR-DD-IP

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

DALI RC BASIC SO. Control unit Operating instructions

EBDSPIR-PRM, EBDSPIR-PRM-IP

PRESENCE DETECTOR PD-C360i/24 KNX ECO (EP )

LED control gear. LED control gear

Lighting Management solutions

Product and functional description

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

T7560A,B,C Digital Wall Module

LED light engine / OLED LED compact. Uengine STARK DLE PREMIUM system data sheet STARK DLE

How To Use A Power Supply On A Powerline 2.2 (Ai)

Emergency lighting units EM powerled

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

13 SERIES. Electronic step relays A

FIRERAY 2000 Installation Guide

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

15 Series - Electronic step relay and dimmer. Features SERIE

Operating instructions Optical distance sensor O1D100 O1D / / 2012

Operating instructions

HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15

500r+ Installation and User Guide

Installation and User Guide

Dual Technology Ceiling Mount Sensor

PRODUCT MANUAL IRSC. IRSC-Plus. Air-Conditioning controller ZN1CL-IRSC. Program version: 5.14 Manual edition: 5.14_a

Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

GREISINGER electronic GmbH

HERZ-Thermal Actuators

PSTN Home Alarm System

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

SMART SENSOR COLLECTION

Transmitter Actuator 230V wave UP 560. Operation

DSM155 Digital LED Light Meter User s Manual DSM155

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Cross-beam scanning system to detect slim objects. 100 mm in

Inwall Room Temperature Unit

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

AlarmSense 2-wire detection and alarm system. Product Guide

M1000 Process Alarm Monitor

Page 1. Description

Additional Instruction

DIGITAL CONTROLS OVERVIEW

User and installation manual

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

2013 Wireless Video Intercom INSTALLATION GUIDE

AUTODIALLER / QUICKDIALLER - SA132

Tebis application software

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

OVVIO LED SUSPENDED CEILING. PG-DR versions

Inwall 4 Input / 4 Output Module

9452/9453 Installation and User Guide

DALI Driver Configurator User Guide

New XUY roller sensors

9448 Installation and User Guide

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

Movement/monitoring 1307/1.0 (6325xx)

LW A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

KNX Lighting Control System

Wireless Home Security System Product Manual (Model #80355)

FG MOISTURE MONITOR Installation & Operation Manual

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Glass sensor 2gang with room thermostat Glass sensor 3gang with room thermostat

AC-115 Compact Networked Single Door Controller. Installation and User Manual

FIREDEX Conventional Fire Panels

PART 1 PRODUCT (GENERAL)...1.

Actuator for modulating control AME 435

Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Duct Humidity Transmitter

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Multi-Range Programmable DC Power Supplies 9115 Series

EPSON Perfection 2450 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. US letter or A4 size ( inches [ mm])

Dome Camera with IR Night Vision

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P340-2 umodule SPOT PHASED OUT NTC

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide

LCD -based Intelligent Burglar Alarm System. User Guide. Ver 2.0

Transcription:

SMART Sensor 5DPI 19fe Ambient light sensor and presence detector for lighting control Optional ambient light sensor and presence detector for devices from the y II generation Can be remote controlled Compact dimensions for luminaire installation Simple cable connection to the ballast via SMART interface Power supply via ballast Lighting control and presence detection can be deactivated Individual adjustment of the parameters with configuration software Optional with corridorfunction profile Optional connection with second ballast possible via accessory cable Max. installation height 5 m 5-year guarantee 39 5 3,5 19 Technical data Power supply via SMART interface Current draw 1 ma from SMART interface Operating temperature 0... +60 C Storage temperature -0... +65 C Type of protection IP0 Max. casing temperature tc 63 C 1,5 16 16,7 3, 5,6 È Standards, page 5 Wiring diagrams and installation examples, page 6, 7 Type Article number Packaging, carton SMART Sensor 5DPI 19fe 80009 0 pc(s). SMART Sensor 5DPI 19fe cf n.o. 800099 0 pc(s). SMART Sensor 5DPI 19fe cf 01 800097 0 pc(s). SMART Sensor 5DPI 19fe cf 30 800098 0 pc(s). Specific technical data Type Detection Max. cable length Control output (devices) corridorfunction profile Light detection angle asymmetric Light measurement at the sensor head 1 Illuminance (factory default) Motion detection angle symmetric SMART Sensor 5DPI 19fe 31 40 1,000 lx 500 lx 9 0.8 m SMART Sensor 5DPI 19fe cf n.o. 31 40 1,000 lx 500 lx 9 0.8 m never off SMART Sensor 5DPI 19fe cf 01 31 40 1,000 lx 500 lx 9 0.8 m switch-off 1 minute SMART Sensor 5DPI 19fe cf 30 31 40 1,000 lx 500 lx 9 0.8 m switch-off 30 minutes 1 The measured value at the sensor head corresponds to approx. 60 to 3000 lux on the surface measured. The illuminance is set for a room defined by Tridonic. Depending on the actual room (reflectance) the measured illuminance may deviate from this value. The illuminance should therefore be checked in the installation and adjusted if necessary. www.tridonic.com 1

SMART Sensor T5 Clip + Cap Clip for mounting the sensor directly to the lamp and cover to protect against indirect light Type Article number Packaging, bag Packaging, carton SMART Sensor T5 Clip + Cap 86459499 10 pc(s). 00 pc(s). SMART Sensor T8 Clip + Cap Clip for mounting the sensor directly to the lamp and cover to protect against indirect light Type Article number Packaging, bag Packaging, carton SMART Sensor T8 Clip + Cap 86459500 10 pc(s). 00 pc(s). www.tridonic.com

SMART Sensor Cap Cover to protect against indirect light Type Article number Packaging, bag Packaging, carton SMART Sensor Cap 86459501 50 pc(s). 500 pc(s). REMOTECONTROL IR6 Optional infra-red remote control Switching on and off (On/Off button) Dimming (Up/Down button) Activation of automatic lighting control Setting the threshold control point (Set button) Type Article number Dimensions L x W x H Packaging carton REMOTECONTROL IR6 8000647 86.5 x 40.5 x 7. mm 500 pc(s). www.tridonic.com 3

SMART Sensor Extension Cable Cable for optional connection of the sensor with a second ballast Only use with SMART Sensor 19fe Ordering Data Type Article number Length Packaging, carton SMART Sensor Extension Cable 86459176 0.8 m 1,500 pc(s). SMART Sensor Cover Frame Cover frame for attaching the sensor directly to the luminaire casing 6,4 Ø34 16,5 5 1,4 3,4 7,8 Type Article number Packaging, bag Packaging, carton SMART Mounting Ring 5DPI 8645948 50 pc(s). 00 pc(s). www.tridonic.com 4

SMART Sensor 5DPI 19fe In combination with the based on the y-ii platform, SMART Sensor 5DPI 19fe provides the basis for an easy-to-use and cost-effective lighting system. When the sensor detects movement it triggers a predefined motion detection profile in the ballast. Constant lighting control acts exclusively on the presence value. As the amount of natural ambient light changes the illuminance from the artificial lighting system is adjusted. With a SMART Sensor 5DPI 19fe installed, based on the y II platform, can be switched on and off via DSI or DALI signals, switchdim or the mains. With the sensor installed the setpoint value (dimming) can be temporarily changed by means of DALI or switchdim. Set point can be changed and set via REMOTECONTROL IR6 on the sensor. The configuration of the sensors is done via masterconfigurator software tool (version.0 or higher). For further information please refer to the y II documentation. Standards EN 61547 EN 61347-1 EN 61347--11 EN 55015 Installation Before connecting / disconnecting the sensor to / from the SMART interface the power supply has to be switched off Only for the use of ballasts with y II label The SMART Sensors have to be connected only to the SMART interface of based on the y II range The SMART interface is not SELV The installation instructions for mains voltage therefore apply Please ensure that the detection range of the sensor lies in the lighting area of the controlled luminaires. Please ensure that the detection ranges of the sensors do not overlap. This may have influence to the lighting control. Heaters, fans, printers and copiers located in the detection zone may cause incorrect presence detection. To avoid false readings, the sensor should be installed so there is no direct light from the lamp in the detection zone. The back side of the sensor should not be exposed to the light output of the lamp as this can negatively influence the operation of the sensor. To avoid any malfunction we strongly recommend: Use the SMART Sensor cap (which can be ordered as accessories) or Alternatively: Mount the sensor away from light exposure from behind To avoid false measurements caused by the light from other luminaires we recommend that the sensor should be located centrally in the luminaire. Sensor wires must be routed separately from the lamp wires and mains cables otherwise the lighting control system may malfunction. If separate routing is not possible (for reasons of space) shielded lamp wires and mains cables must be used Application wiring and functionality see separate user manual smartsensor. Mounting with cams at the sensor housing: 13.5 ±0.10 Ø 19.0 +0.10 Ø 5. +0.10 variant 1 drilling hole for IR-Receiver 1.5 ±0.10 1.5 ±0.10 On the housing of the sensor are fixing cams integrated. With this cams the sensor can be mounted directly in the luminaire housing. Size of the sheet: 0.8 1. mm Ø 19.0 +0.10 3.8 +0.0 variant drilling hole for IR-Receiver Note: By the installation is to be paid attention to the fact that the IR sensor and the light sensor is visible. Mounting with cover frame in luminair housing: SMART Mounting Ring 5DPI (art.no. 8000910) Size of the sheet: 0.8 1. mm 13.75 +0.10-0.10 Ø 1.8 +0.0 Ø 5.3 +0.0 www.tridonic.com 5

A) corridorfunction with integrated motion sensor Soft start of is followed by activation of motion detection and constant light control. 3 4 6 optional SMART Sensor Extension Cable (art.no. 86459176) B) corridorfunction with external motion sensor The corridorfunction is activated when a standard motion sensor is connected to the central interface (D1, D). If movement is detected by the motion sensor the ballasts switch on; if no movement is detected they switch to the absence value after the delay time on the motion sensor. Only the presence value is constant light controlled. For the corridorfunction profile there will be used the profile of the sensor. The motion detector integrated in the SMART Sensor is inactive in this mode. 3 4 optional SMART Sensor Extension Cable (art.no. 86459176) C) Compatibility with the controllers must be checked before a PCA EXCEL one4all with connected SMART Sensor 5DPI is integrated in a DSI or DALI light management system. 3 4 DSI Switch ON/OFF via DSI command. DSI command = 0 zero-power switch OFF, DSI commands > 0 switch ON. ON means activation of the motion detector by sensor. DALI Switch ON/OFF via DALI commands. Control possible via DALI commands. For more information see the y II documentation. Extension via SMART Sensor Extension Cable If DALI is used both ballasts must be in the same group and controlled via group commands. DALI DSI optional SMART Sensor Extension Cable (art.no. 86459176) D) switchdim with switchdim function can be switched ON/OFF by a short key press. By dimming up and down with a long press the set-point of the light control can be changed temporarily. After switching OFF and ON again the previous setted value will be activated again. If presence control and switchdim are used in combination there may be loss of synchronism if several ballasts are connected to the same momentary-action switch and the ballasts or the sensors connected to them are large distances apart. N L 3 4 optional SMART Sensor Extension Cable (art.no. 86459176) www.tridonic.com 6

Light regulation Presence detection Precise light measurement via photo diodes. 31 h h a x 1.50 m 0.90 m 0. m.00 m 1.0 m 0.30 m.50 m 1.50 m 0.37 m 3.00 m 1.80 m 0.45 m 3.50 m.10 m 0.5 m 4.00 m.40 m 0.60 m 4.50 m.70 m 0.67 m 5.00 m 3.00 m 0.75 m 1 m = 1.094 yd h 9 d Detection area: 46 Scope:.5 m presence detection 5 m motion detection h* d 1.50 m 3.10 m.00 m 4.10 m.50 m 5.0 m 3.00 m 6.0 m 3.50 m 7.0 m 4.00 m 8.30 m 4.50 m 9.30 m 5.00 m 10.40 m x * The recommended maximum room height for office applications is 3 m and for corridor applications for example 4 m. x Calculation of the diameter: d = tan(0,5 a) h a The sensor detection zone is dimensioned so that the entire work area is covered and evaluated, not just a single point. This ensures that false readings are not made as a result of moving objects across the work surface such as white paper, which would otherwise lead to a sudden change in the brightness level. The absolute value depends on the luminaire used and the reflectance in the room. The rate at which the dimming value is changed is dynamically linked to the overall lighting level. The following operating modes can be set for lighting control via the masterconfigurator configuration software (version.0 or higher): Active Inactive Constant light control is active. Constant light control is deactivated. The lighting switches to a defineable value. Permanent change of light control set point The Up/Down button on the remote control enables the setpoint value to be changed temporarily. Pressing the Set button on the remote control stores the setpoint value permanently. The light source indicates that the value has been stored successfully by flashing twice. In DALI operation the setpoint can be adjusted also with the masterconfigurator (version.0 or higher). The DALI RESET command restores the default value set at the factory. Bright-out If the nominal illuminance (e.g. 500 lux) is exceeded by more than 150 % (e.g. 750 lux), the lighting is switched off even if motion is detected. The lighting is switched on again when the measured light value falls below the setpoint. This function can be adjusted via the masterconfigurator (version.0 or higher). The following operating modes can be set for the motion detector via the masterconfigurator configuration software (version.0 or higher): Active Only Off Never Off Inactive The light is switched on or off automatically depending on whether or not there is a person in the room. The motion detector only switches the connected lighting off. The luminaires are switched on manually via the connected external switch or infra-red control. If it has not detected any movement the sensor dims to the Absence value parameter and remains at this value The motion sensor is deactivated. The light must be switched on or off manually. Run-on time The time that starts as soon as the presence of a person is no longer detected. If the presence of a person is detected again during the run-on time the run-on time is restarted from zero. If no presence is detected during the run-on time the fade time is started as soon as the run-on time expires. Fade time The time during which the luminous intensity is faded from the presence value to the absence value. Switch off delay The time during which the absence value is held before the lighting is switched off. Depending on the profile selected the switch-off delay may have different values or may not be defined. Absence value The luminous intensity when there is no person present. Presence value The luminous intensity when persons are present. Dead time Manual-off If the system is switched off manually via the switch or REMOTECONTROL IR6 the motion sensor is deactivated. At the end of a delay time if motion has not been detected the motion sensor is activated again. If the sensor detects motion during the Manual-off delay, the time will be reset to the start. www.tridonic.com 7

General settings Parameter Default Values Motion Detector enabled, on/off Light Regulation enabled Setpoint Light Regulation 500 lx Bright-out timeout 0 min Bright-out threshold 150 % Switch On Value auto (calculated) Default Parameter Motion Detector Parameter Default Values Adjustable range 1 Fade-in time < 0.7 s A Presence value controlled Absence value to 100 % Run-on time 0 min 10 s to 4.4 min 3 Fade time 3 s 0 90.5 s B Absence value 10 % 0 % to presence value 4 Switch-off delay never off / 1 min / 30 min 0 s to 4.3 min /never off 5 Fade-off time < 0.7 s Manual-off 0 min 3 s to 4.5 min www.tridonic.com 8