Electric Power in Airplane. Student: Maja Knezev Course ELEN 615, 31 st August 2006



Similar documents
Introduction to Aircraft Design and Aviation Systems (ENG3005)

ELECTRICAL. Primary electrical power is provided by two engine driven generators which supply three-phase, 115 volt 400 cycle alternating current.

ELECTRICAL DISTRIBUTION POWER SYSTEMS OF MODERN CIVIL AIRCRAFTS

Direct Current Motors

B 737 NG El ectrical

UPS Applications and VRLA Battery Sizing

787 No-Bleed Systems: Saving Fuel and Enhancing Operational Efficiencies

ELECTRICITY IS IN THE AIR

Design of electrical power system for a 1000MW nuclear power generating station

ROLLING STOCK MAINTENANCE REPAIR & OVERHAUL (MRO) Turbo Power Systems Capability & Services

Alternating Current and Direct Current

DIRECT CURRENT GENERATORS

MAJORSINE Power Inverter

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

Contactless Power Transfer : Inductive charging of EV

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.

I = V/r P = VI. I = P/V = 100 W / 6 V = amps. What would happen if you use a 12-volt battery and a 12-volt light bulb to get 100 watts of power?

Specification Requirements DBL 700MX and 1000MX Series UPS

Charger Output AC Ripple Voltage and the affect on VRLA batteries

Hybrid System Overview

POWER AND VOLTAGE RATING

Fundamentals of Power

SYNCHRONOUS MACHINES

Electrical Systems. <Presenter>

SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE WELDERS

Inverter technology. bulletin

MILITARY STANDARD. Aircraft Electric Power Characteristics

Phase Modular Finally the benefits of Modular ups are for all

Transfer Equipment Controls

Three-Phase Electric Power Distribution for Computer Data Centers

Three-phase AC circuits

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

POWER WITH PURPOSE. Delivering innovative end-to-end electrical power systems integration

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

Welcome to Linear Controls Quarterly Training

47000 SERIES - ELECTRONIC TRANSFORMERS

High-Efficiency AC Power Distribution for Data Centers

Replace That Bad Diode

Process and Motor Controls in Central and Remote Buildings: PlantWeb Center, the Intelligent Remote Building

Constant Voltage Charger Selection for VRLA Batteries

SiteRanger tm. Power quality / site monitoring. Comm/net Systems, Inc.

Inductance. Motors. Generators

STUDY GUIDE: ELECTRICITY AND MAGNETISM

UNIT 3 AUTOMOBILE ELECTRICAL SYSTEMS

Qualitative Analysis of Power Distribution Configurations for Data Centers

Load Bank Buyers Guide 60 hz models

What is a multimeter?

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Section B: Electricity

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Automatic Voltage Regulator User s Manual

Electrical System From The Top Down By Rick Denney, GMC Eastern States April 2006

An Easy to Build and Operate Induction Generator

Mathematical Modeling and Dynamic Simulation of a Class of Drive Systems with Permanent Magnet Synchronous Motors

FAULT FINDING MANUAL For Self Excited and Separately Excited Generators

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Rotary Phase Converters

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Resistors in Series and Parallel

Modelling, Simulation and Performance Analysis of A Variable Frequency Drive in Speed Control Of Induction Motor

The Basics of Digital Multimeters

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Motors and Generators

Additional Solar System Information and Resources

Photovoltaic Solar Energy Unit EESFB

High voltage power supply (1 to 20 KV)

GENERAL POWER SYSTEM WIRING PRACTICES APPLIED TO TECNADYNE DC BRUSHLESS MOTORS

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Thyristor-controlled power supplies and battery chargers

Installation Instructions

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Power transformers. Special transformers Railway

Lab 8: DC generators: shunt, series, and compounded.

Power Plant Electrical Distribution Systems

WHITE PAPER. DC Motors Explained. DC Motors Explained: White Paper, Title Page

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

SINGLE ENGINE TURBO-PROP AEROPLANE ENDORSEMENT

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Advance Electronic Load Controller for Micro Hydro Power Plant

Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP

Inverter / Charger Installation General Operations and AC and DC Connections

A relay capable of the generator s starter amps with a coil that draws no more than 12V.

POWER EQUIPMENT AND DATA CENTER DESIGN

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

Survey of Harmonics Measurements in Electrical Distribution Systems

Preview of Period 16: Motors and Generators

User s Manual AURORA 1.2K/2.2K

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Objectives. Electric Current

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Figure. 1 - Split Phase 240/120V circuit (180 phase shift)

PS-6.2 Explain the factors that determine potential and kinetic energy and the transformation of one to the other.

Power Quality Standards for Electric Service

WINGLIKE ELECTRONICS CO.,LTD

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

Transcription:

Electric Power in Airplane Student: Maja Knezev Course ELEN 615, 31 st August 2006

Power sources on aircraft engine driven AC generators, auxiliary power units (APUs), external power and ram air turbines.

Voltages in airplane Aircraft electrical components operate on many different voltages both AC and DC. The most of the aircraft systems use: -115 volts (V) AC at 400 hertz (Hz) - 28 volts DC DC power is generally provided by self-exciting generators containing electromagnetics, where the power is generated by a commutator which regulates the output voltage of 28 volts DC. AC power, normally at a phase voltage of 115 V, is generated by an alternator, generally in a three-phase system and at a frequency of 400 Hz.

Why use two different generators (AC & DC)? REDUNDANCY!!! The Airplanes have both transformer rectifiers to turn the 400 HZ voltage into DC for the 28 volt buss, and they also have a static inverter to create the AC 400HZ in case the airplane is down to battery power only (meaning you have lost engine generators, APU generators etc.). The aircraft *battery offers a short-term power storage capability. So there are other methods used for providing back-up power: 1.Ram Air Turbine(RAT) 2.Back-Up Converters 3.Permanent Magnet Generators (PMGs) *battery- From [7] nominal values are: Vn=24V Cn=53Ah m=96lbs len.=13in. wid.=11in. height=11in.

Emergency power generation 1. Ram Air Turbine(RAT)- air driven turbine stowed in aircraft ventral or nose section. Gen. Sizing varies between 5 and 15kVA. Rat is intended to furnish the crew with sufficient power while attempting to restore primary generators 2. Back-Up Converters- The back-up generators are VF. This supply is fed into back-up converter which converts the AC power to DC and then generates three phase 115 VAC 400Hz 3. Permanent Magnet Generators are used to generate 28VDC emergency power for high-integrity systems. In case of Boeing 777 there are 13 PMGs across the aircraft critical control systemsflight control, engine control and electrical system

Why not just use DC generation? DC systems are limited to around 400A or 12 kw for two reasons: 1. The size of conductors and switchgear to carry necessary current becomes prohibitive 2. The brush wear on brushed DC generators becomes excessive with resulting maintenance costs if levels are exceeded. Main advantage of AC power is that it operates at a higher voltage Pro: 1.Higher voltages are important in the transmission of power. Higher voltage Lower current Lower loses 2.Current conductors are generally heavy. So reduction of current saves weight, a very important consideration for aircraft system Con: Higher voltages require better standards of insulation

DC and AC generator sizes- comparison AC generators are typically oversized to handle starting and to provide light enough engine loads to facilitate speed regulation (Fig 1). DC generators are smaller in size (Fig 2). (Generated much less power though) Pictures are taken from[8]

Why 400 Hz? Universal emf equation says: E = 4.44*f*n*a*B So for a given voltage and number of turns, increasing the frequency allows for decreasing the cross-sectional area of the core without bringing the core into saturation. Pro: The advantage of running an electrical system at 400 Hz rather than 60 Hz is that the power supplies are smaller and lighter. Con: This reduction in weight comes at a price, since high-frequency electrical systems are less efficient, because transformer losses increase with frequency (mostly due to increased hysteresis losses, eddy currents, skin effect, etc.). So, the 400Hz figure represents an optimal trade-off between efficiency and compactness

Electrical Loads Motors and actuation - are used to drive a valve or an actuator 1.DC motors are usually used for linear and rotary, fuel valve actuation and starter functions 2.AC motors are usually used for continuous operations during flight Lightening services - are powered by 28VDC or by 26VAC provided by auto transformer from the main AC buses. Usually filament bulbs are used for lighting. They vary from 600W for lending lights to few watts for minor internal illumination uses.

Electrical Loads Heating services are used extensively. - anti-icing and de-icing systems can consume tens of kvas This power does not have to be frequency stable and can be variable frequency which makes it much easier and cheaper - windscreen heating Subsystem controllers and avionics system - Line replaceable units (LRUs) are used for control, communication and navigation functions. They may require DC or AC power depending upon their function and modes of operation. Usually they have internal power supply units to convert aircraft power to electronic voltages (+-15 and +-5)VDC

Using Laptop in airplane PC power is available in First and Business on all international B747-400 and A330-300 aircraft. This system provides 110V AC (60 Hz) power and accepts most household power plugs including: Australian 2 or 3 pin, European 2 pin, Japanese 2 or 3 pin and USA 2 or 3 pin. Customers using UK 2 or 3 pin plugs need to use an adaptor. PC power supply 115 volts (V) AC is converted from main AC source on 400Hz to 60Hz using frequency converters In case of power outlets 75 Watts of power draw per seat is available

Using Laptop in airplane In some situations power outlets in aircraft 115 volts (V) AC on 400 Hz are available and then passenger has to use adapters that are either acquired in airplane or are personal. Adapter [5]:

Power Transmission Lines are sized according to voltage drop and other considerations. Main generator feeders on a 12OkVA/channel civil system (B777 and B767-400)require 2 x 0 gauge wire per phase for the main generator feeders. The present sensible rated current limit is - 400 Amps for power switching; equivalent to around 12kW for dc and 12OkVA for ac power. Practical limitations are based upon surviving fault conditions with several times rated current values as well as switching normal rated currents. The contactors may therefore have to survive fault currents of several thousand amperes

References [1]Aircraft electrical systems and why they operate at 400 Hz frequency by Aspi Wadia of GE Aircraft Engines: http://www.wonderquest.com/expoundingaircraft-electrical-systems.htm [2 ] http://www.qantas.com.au/info/flying/intheair/communications [3] http://www.aerospaceweb.org/question/electronics/q0219.shtml [4] http://www.pcworld.com/article/id,111982-page,1/article.html [5] In-flight Power Manual http://www.walkabouttravelgear.com/graphics/invert.pdf [6] I. Moir,A. Seabridge, Aircraft systems: Mechanical, Electrical and avionics subsystem integration, AIAA Education Series, Ohio, 2001 [7] http://www.saftbatteries.com/020-ms_aviation/20-20- 10_Engine_starting.asp [8] http://www.power.goodrich.com/products/ac.shtml

More details needed Detailed load characteristics, during steady state operation, during start up. Detailed ratings on all generators, backups and regular ones. Monitoring and control details of when to kick in emergency operations.