Process and Motor Controls in Central and Remote Buildings: PlantWeb Center, the Intelligent Remote Building
|
|
|
- Marcia Marshall
- 10 years ago
- Views:
Transcription
1 Apr-07 Page 1 This paper introduces the PlantWeb Center and the use of Intelligent Motor Control. Emerson Process Management All rights reserved. DeltaV, the DeltaV design, SureService, the SureService design, SureNet, the SureNet design, and PlantWeb are marks of one of the Emerson Process Management group of companies. All other marks are property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warrantees or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the design or specification of such products at any time without notice.
2 Apr-07 Page 2 Contents Introduction Basis of Comparison Legacy DCS or DeltaV UPS Systems Motor Control Center or IEC Contactors Central Control Building or Remote I/O Center Cabling Comparisons DeltaV: The Largest Difference Summary PlantWeb Center The Intelligent Option
3 Apr-07 Page 3 Introduction There are many reasons to locate controls either at the operating structure or several hundred feet away in a central location. Preference and precedent are strong reasons for centralization; they support the pattern established years ago. Maintenance personnel are often staffed in the central building adjacent to the I/O and motor control center rooms. This has become less important as these systems have improved. Less maintenance is required, and much of it can be managed from the unit or plantwide central facility with HART or FOUNDATION fieldbus derived information transmitted to any company site. Intelligent VFDs and motor controls are here now and much more information is available from these newer systems than we have been accustomed to getting. Capital cost is a stronger factor than ever. This is because of additional choices not available just a few years ago. Relatively recent technologies which, when combined, make a strong case for decentralization include: Scalable hybrid digital control systems, the DeltaV system, for example A subset of the DeltaV system, along with a trend to 24VDC-powered instruments is a reduction of the UPS system. Finger-safe IEC motor control, with performance matching that of traditional MCCs. The quality of remote I/O centers, along with the ability to communicate via Ethernet or other bus systems. A subset of remote centers is a large reduction in cabling. The scope of this study is defined by an actual project executed by FABCON in It was a remote I/O building containing DCS (PROVOX) I/O and traditional NEMA motor control centers (MCCs). Pertinent counts are: UOC controllers, 320 point 2 HART analog in points 144 HART analog out points 16 Discrete points, in & out 508 Size 1 starters 40 Size 2 starters 4 Size 3 starters 4 Size 4 starters 4 Size 5 starters 5 30 ampere fusible switch units ampere fusible switch units 7
4 Apr-07 Page 4 Basis of Comparison Legacy DCS or DeltaV The PROVOX project contained the I/O listed in the introduction as well as controllers. Terminals and software, while not located in the remote I/O center, were also included. From these P.O. line items, an equivalent DeltaV system was specified and priced. The DeltaV prices were list. The DCS system was, of necessity, enclosed in cabinets. Because of its IP20 finger-safe design, the DeltaV system can be surface- or rail-mounted. The cabinet pricing is included in the DCS total. The DeltaV equivalent hardware was split into two systems. These, combined, consisted of: 2 M5 Plus controllers 3 Passthrough power supplies 4 2-wide carriers 8 8-wide carriers 18 8-point HART analog in cards 2 8-point HART analog out cards 7 32-point discrete in cards 37 8-point discrete out cards Configuration was not addressed. UPS Systems An item greatly affected by choice of digital control system needs is required power. Another factor that affects instrument power is the almost complete availability of instruments accepting 24 VDC power at lower usage levels. PROVOX, along with other legacy systems, uses AC input DC power supplies. In the PROVOX case, two AC inputs could be furnished to the power supply for some level of redundancy. The power supply output is still common, but multiple units can be paralleled. At the advent of DCS control systems, many field devices still required 120 VAC for power. This leads to a cumbersome design if you want to stay online for some time after a power failure. One of the AC supplies is from a UPS and the other from a 120 VAC distribution panel supplied from an MCC via a step-down transformer. The UPS consists of a 480 VAC, from a different MCC, to 24 VDC rectifier, a battery bank, a 24 VDC to 120 VAC inverter and a static switch. The battery design is 14 minutes of operation. Examining the UPS system confirms that several conversions are made. They are: 480 VAC to 24 VDC in the UPS 24 VAC to 120 VAC in the UPS 120 VAC to 24 VDC in the DCS system The system proposed for DeltaV and field instruments is a 480 VAC to 24 VDC rectifier capable of trickle charge and a 14-minute battery. This 24 volts is distributed to 2-wide carriers for system power and to 8-wide carriers for field power. To furnish even more security than the UPS above, a second source is a 120 VAC to 24 VDC rectifier and equivalent battery bank fed from a lighting panel. With intelligent switching, we have twice the time, and one battery can be serviced or replaced while we still have backup from the other.
5 Apr-07 Page 5 The inefficiency losses involved above would consume 4 KVA of the 10 KVA UPS if each conversion has 15% loss. 20% is a more likely number. After correcting for latent heat, more than 1½ tons of air conditioning would be needed for just these losses. Motor Control Center or IEC Contactors The three MCCs were requoted to essentially match the 1998 project. The list of combination starters and switches are as listed in the introduction. Each Mcc has an 800-ampere disconnect for incoming power and 800 ampere horizontal buses. The lineup is a 4-section back-to-back MCC and two 3-section back-to-back MCCs. All equipment is fusible. This array was matched by quotes from the same vendor for equivalent IEC contactors and overload relays. In addition, fused switches and IEC bus systems from a major circuit protection vendor were priced in. Again, all equipment is IP20 finger-safe or is furnished with protective shrouds to accomplish a non-contact electrical system. MCCs are in their normal rugged metal enclosures. That means a size 1 starter takes up 1.4 cubic feet of space. In a front only array, 2.8 cubic feet would be used. By contrast, an IEC equivalent requires less than 0.1 cubic feet. Required clearance spaces for each compound this difference. Heat dissipation for the 20 sections of MCC is, by G.E. estimating techniques, 8333 watts. After conversions and corrections, this is a need for 3.8 tons of cooling if cooled to comfortable personnel conditions. This could be in order if the space is shared with legacy DCS gear, limited to around an 85 F, environment. A case can be made for ventilation in northern climes, but Gulf Coast locations present a need for huge amounts of cooling air as the ambient temperatures approach 104 F., the MCC limit. The drawbacks to huge amounts of cooling air are fan size, motor horsepower and their footprint, and the need for large filter installations with significant maintenance requirements. The IEC arrangement loses about 2000 watts, a less than 1-ton penalty. Central Control Building or Remote I/O Center This whitepaper is to show the documented advantages of placing a majority of the control systems as close as reasonable to the process being served. Three types of buildings will be considered. First is dedicated room(s) in a masonry control building, designed by an architect or experienced plant facilities designer. Next is a large rugged painted steel panel structure with a structural base hefty enough to resist changes due to lifting, loading and unloading. The last case, size permitting, is a modular panel system of steel-clad foam composite wall and roof panels mounted on a FABCON structural base and floor. The space requirement for the DCS and MCC installation is 480 square feet in either location. For DeltaV and MCCs, 400 square feet is needed, and for DeltaV and IEC gear, 208 square feet will fill the bill. With a cable tray system over the MCCs, 12 feet is in order from floor to ceiling. In the last case, because all items are wall mounted, either surface- or rail-, the tray can be outside meaning an 8-foot tall building will suffice. To look at this another way, the first two cases need 5760 and 4800 cubic feet respectively, while the last case uses 1664 cubic feet. Lighting is proportional to area, and HVAC requirements are a function of the volume.
6 Apr-07 Page 6 Cabling Comparisons This comparison is based on these assumptions: The central control building is 750 feet (note 1) from the process unit. Junction boxes are in the process structure to collect power and control cables. From these boxes, multi-pair instrument cables and multi-conductor control cables are run to the control building. Also field devices are 100 feet (note 1) from the junction boxes. The remote I/O building is 250 feet (note 1) from the process and all cables are run from the device to their termination in the building. The central control building is 750 feet from the remote I/O building. No junction boxes are used. A further assumption is that the 480 VAC source is between the buildings. If it is located beyond the control building from the process, the additional 4500 feet for the 6 feeders will negate other cable savings. An additional feature is that elaborate grounding is not needed for the DeltaV system as it was with the DCS systems. Note 1: these are averages for purposes of estimating cables. DeltaV: The Largest Difference This was the most startling difference, a 69% reduction for the DeltaV case. Note that the prices are not estimated. The DCS data is from copies of purchase orders and the DeltaV system is priced at list. Although not installed in the I/O room, wherever located, consoles and control software are included. The installed DCS system is $304,000 including cabinetry. The installed DeltaV system is $94,000 including mounting on plates. Because of the large difference, this case is for historical reference only. However, as this is being written, a project similar to that used in this comparison is in the FABCON shop; and that includes PROVOX. The 69% reduction equates to $210,000. Reductions in area and HVAC needs will be reflected in the buildings comparisons. The UPS system is similarly downsized both in capacity and complexity. A 10KVA UPS was purchased for the 1998 project for $16,900. Getting even more protection without the DC/AC inverter and second AC/DC conversion can be done as described for $5000 installed versus the $17,000 for the UPS This is a reduction of 70% or $12,000. In addition, a smaller area is in order, less heat is generated and a transformer and distribution panel are eliminated. These show up in the buildings comparisons.
7 Apr-07 Page 7 IEC Motor Control Advantages The actual 1998 project used an MCC considered to be very top of the line. I chose to get current quotes from a more competitive vendor for both the NEMA and IEC versions. The NEMA system is $60,000 installed, the IEC system $34,000. This is an installed difference of $26,000, or a 43% reduction. As above, the area and HVAC reductions are in the buildings comparisons. Remote I/O Centers have the Edge The building site and type are influenced by other factors, principally preference and the equipment to be housed. Although three different sizes and three types of construction are considered, the cost differential for each central versus remote option is fairly constant at $20,000. It is when the leap is made to smaller, more efficient equipment combined with placing I/O adjacent close to the process that real savings are realized.
8 Apr-07 Page 8 Summary The cost differentials mentioned throughout this paper are displayed in the table below. Location Control Type Motor Control Control System Motor System Cables UPS Building TOTAL Central DCS MCC ,000 Central DeltaV MCC ,000 Central DeltaV IEC ,000 Remote DCS MCC ,000 Remote DeltaV MCC ,000 Remote DeltaV IEC ,000 The first and fourth cases are, at present, unlikely. As mentioned before, FABCON has an example of case 4 in our shop in April This apparently is an addition to a system in operation. However, new legacy DCS installations will not happen, or at least, should not. The real savings comes when a DeltaV client adds the options of IEC motor control and placement of I/O adjacent to the process unit. This difference is exhibited in the second and last case. The reduction is $ or 36.5%. Other Savings and Considerations Only the hardware case has been considered. There are several other issues. Design, development and documentation are much less with any system other than a DCS. Even in the PLC/HMI case, this can more than offset the hardware difference. Refer to DeltaV whitepaper DeltaV versus PLC/HMI in a Highly Discrete Application dated January A standard documentation package; if FABCON standard components are used. These would be fill in the variables for layouts, schematics etc. Discrete and continuous control devices designed to IP20 or higher are, in almost all cases, modular and easy to apply and amend. This is a considerable savings in engineering. A full service fabricator will have the skills on hand and not have to purchase engineering. The high-value space freed-up by a migration from a central legacy system to a process-adjacent new system can be used for offices or IT systems. In a new installation, the building cost is reduced, or where available footprint is tight, the space can be better used.
9 Apr-07 Page 9 With communications now available, a multi-unit plant migrating to the DeltaV system can include upgraded motor control in the remote I/O centers and consolidate I & E maintenance in a central location and perhaps reduce staff. The next steps, of course, are control center centralization, asset management and integration with ERP. Other issues are: Benefits of a single purchase order Reduce need to supervise construction crafts F.A.T. and simulation are possible before acceptance onsite Small components are reasonable enough to replace, not maintain Reduced engineering and architectural needs Ability to easily incorporate other systems such as: Switchgear Analyzers and sample systems Pressurization, purges and air locks Safety relay systems Wet labs Maintenance consoles Perhaps the most important additional benefit is the ability to totally specify, furnish and document the I & E systems from sensor, valve and motor through the human interface and beyond, fully configured and ready to use.
10 Apr-07 Page 10 PlantWeb Center the Intelligent Option The most advanced version of remote I/O buildings by FABCON is the PlantWeb Center. This center combines all latest technologies for optimal use of smart digital asset management. In particular, the product utilizes Foundation Fieldbus and Device Net communications to further minimize wiring. Hardware costs are about equivalent to the DeltaV IEC Remote case. There are savings in wiring, power and building size; however, the added cost of intelligent hardware roughly equals those savings. The use of multivariable transmitters can further reduce I/O cards as well as wiring. The real savings, however, comes from the powerful checkout, configuration, maintenance, operations and asset management features. Because this paper concentrates on hardware and documentation aspects, we will not address these benefits available with Emerson and other FOUNDATION fieldbus devices. The motor control features are worth mentioning because they are new to much of the Emerson Process Management community. Besides eliminating the need for hard-wired start, stop and run feedback; the following information is available: Ground fault detection Thermal overload pre-warn Phase loss or unbalance Communication errors Average RMS motor current Memory of previous faults Underload condition Variable frequency drives, particularly those by Control Technologies, offer the above and more. Additional variables include: Speed Direction Trip codes Frequency Preset speeds High and low speed alarms Drive health Braking information Trip, jog and reverse commands This is the highest technology available to processing industries. When combined with the PlantWeb Center completely configured, tested and simulated power and control systems can migrate pneumatics to intelligent digital systems in weeks rather than months. The migration from DCS can make weeks become days.
All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space.
The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space. Terminology: Telco: Dmarc: NOC: SAN: GENSET: Switch: Blade
MAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
QUESTIONS and ANSWERS RFB 745-15-9894, Metal Clad Switchgear and Power Control Room
QUESTIONS and ANSWERS RFB 745-15-9894, Metal Clad Switchgear and Power Control Room 1) When you click on the UTHSCSA Drawing the site takes you to the E-1 drawing no other. Will there be other drawings
Paralleling Switchgear
Paralleling Switchgear By Maurice D Mello, P.Eng. Systems Engineer, GE Consumer & Industrial, Canada What is Paralleling? Paralleling is the operation in which multiple power sources, usually two or more
30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid
Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE
SiteRanger tm. Power quality / site monitoring. Comm/net Systems, Inc.
SiteRanger tm Comprehensive Broadband/ Enterprise site monitoring device for Headend s, Hub Sites. Power quality / site monitoring Focus on power system infrastructure Retrofit legacy devices for remote
Wired versus wireless trade-offs
A PUBLICATION OF THE INTERNATIONAL SOCIETY OF AUTOMATION Wired versus wireless trade-offs How to choose for new installations By Moazzam Shamsi Figure 5. Steam trap monitoring with Rosemount 708 wireless
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
Mixing Sodium and Lead Battery Technologies in Telecom Applications
Mixing Sodium and Lead Battery Technologies in Telecom Applications Paul Smith Shanon Kolasienski Technical Marketing Manager Application Engineer GE Critical Power GE Energy Storage Plano, TX 75074 Schenectady,
100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G
100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G The Opportunity Jones Lang LaSalle, Inc. (the Broker ) is please to offer the fee simple interest in 100 Locust Avenue (the
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
Inverter / Charger Installation General Operations and AC and DC Connections
Inverter / Charger Installation General Operations and AC and DC Connections The Inverter is just one piece. Sometimes, a tendency is to mount the inverter and batteries, and make it work It is better
UPS Applications and VRLA Battery Sizing
TECHNICAL BULLETIN 41-7334 UPS Applications and VRLA Battery Sizing 41-7334/0213/CD www.cdtechno.com The uninterruptable power system (UPS) is used to protect critical equipment and processes from the
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Submit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.
Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's
Case Study - University at Buffalo State University of New York. Lower Energy Usage Costs with Real Time Monitoring, Campus-wide
Case Study - University at Buffalo State University of New York Lower Energy Usage Costs with Real Time Monitoring, Campus-wide Reduce Energy Consumption through Awareness of Energy Use Analyze Power Quality
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Increasing safety, reliability and efficiency for today s data centers
Increasing safety, reliability and efficiency for today s data centers Products and expertise for data center success Drawing upon vast experience in complex industries where uptime is critical, ABB provides
Specification Requirements DBL 700MX and 1000MX Series UPS
Specification Requirements DBL 700MX and 1000MX Series UPS Theory of Operation Upon loss of utility power, the UPS inverter shall continue to provide seamless pure sine-wave AC from the batteries without
Fusible Disconnect Switch
Circuit Breakers Circuit breakers are used in panelboards and switchboards to provide circuit protection and provide a means of energizing and de-energizing a circuit. Siemens Sentron molded case circuit
Element D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General
SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General A. Electrical usage on the Brown campus is presently monitored by a Siemens-brand, web-based central metering system, which includes
ProfessionalPLUS Station Software Suite
Feb-07 Page 1 All you need to configure, control, and diagnose your plant is available on the ProfessionalPLUS Station. Global database, architectured for flexibility and scalability Powerful engineering
EDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
ETZGAR CONVEYOR COMPANY Controls Section v12.05
Section 7 Controls Page Description 7-1 Controls Index 7-2 Motor Data, Enclosure Rating and Abbreviations 7-3 Controls Safety Guidelines 7-4 Fixed Speed Controls Packages 7-5 Three Phase AC Variable Speed
WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE
WHITE PAPER WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE EXPLANATION AND ASSISTANCE FOR APPLYING SOLID STATE SOFT STARTERS IN TRADITIONAL REDUCED VOLTAGE APPLICATIONS Introduction..............................................................2
DIABLO VALLEY COLLEGE CATALOG 2015-2016
HEATING, VENTILATION, AIR CONDITIONING, REFRIGERATION - HVACR Tish Young, Dean Physical Sciences and Engineering Division Physical Sciences Building, Room 263 Possible career opportunities Upon successful
APC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services
Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination
Emerson Smart Firewall
DeltaV TM Distributed Control System Product Data Sheet Emerson Smart Firewall The Emerson Smart Firewall protects the DeltaV system with an easy to use perimeter defense solution. Purpose built for easy
Wireless Field Data Backhaul
October 2014 Page 1 Smart Wireless Gateway 1552WU An Emerson Smart Solution integrates WirelessHART data from remote areas of your plant. Scalable Reduced cost Safer deployment Secure and reliable communications
SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions
SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS POWER DISTRIBUTION RACKS IN A MISSION CRITICAL SYSTEM MODULES IN A MISSION CRITICAL SYSTEM UPS Convertor Main Inverter Load Battery BPC UPS & BATTERY
Electrical Systems. <Presenter>
Review Root Causes of Energy Inefficiency Roadmap to Maximize Energy Efficiency Best Practices Alternative Energy Sources Controls Take Aways Seek Professional Help. ENERGY INEFFICIENCY OF
SMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design
Basis of Design This section applies to the design, installation and integration of metering and monitoring equipment, including: hardware installed in the electrical service and distribution equipment,
Inova SV125 Machine Number 4016589
Inova SV125 Machine Number 4016589 Date of Manufacture: 2011 o Never installed or used; in original crate Configured for 10x10 nested 1.0mL Long syringe Fully automatic vacuum filling and vacuum stoppering
What Is Regeneration?
What Is Regeneration? Braking / Regeneration Manual Regeneration Overview Revision 1.0 When the rotor of an induction motor turns slower than the speed set by the applied frequency, the motor is transforming
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com
PRODUCT PROFILE FEATURES
PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER
Base Station. Base Station. Introduction. DeltaV Product Data Sheet. Adaptable work environment. Scalable to suit your needs. Dedicated functional use
September 2013 Page 1 Use the to build a custom DeltaV workstation to meet your needs. Adaptable work environment Scalable to suit your needs Dedicated functional use Introduction Are you looking for process
8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
Qualitative Analysis of Power Distribution Configurations for Data Centers
Qualitative Analysis of Power Distribution Configurations for Data Centers White Paper #4 2007 The Green Grid. All rights reserved. No part of this publication may be used, reproduced, photocopied, transmitted,
D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.
SECTION 263354 STATIC UPS TESTING AND COMMISSIONING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes 1. System start-up services. 2. Battery charging. 3. Load bank testing. 4. Battery load testing. 5.
Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity
Modular architecture for high power UPS systems A White Paper from the experts in Business-Critical Continuity Abstract Today, more than ever before, energy efficiency and cost-savings are among the top
APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply
APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality
Motherboard- based Servers versus ATCA- based Servers
Motherboard- based Servers versus ATCA- based Servers Summary: A comparison of costs, features and applicability for telecom application hosting After many years of struggling for market acceptance, it
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
Siemens tiastar TM Motor Control Center (MCC) Siemens 2011. All rights reserved.
Siemens tiastar TM Motor Control Center (MCC) Siemens 2011. All rights reserved. tiastar Arc Resistant MCCs UL Validated Testing of Arc-Resistant Motor Control Centers page 2 tiastar Arc Resistant MCCs
SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030)
PART 1 - GENERAL SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030) 1.01 SUMMARY This section describes the operation and control of a drip irrigation system. The major components
APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.
USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS Abstract This application note describes the necessary procedure to use a standard Pacific Power Source Model
12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting
12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.
M-series MD Plus Controller
August 2013 Page 1 The DeltaV MD Plus Controller and the DeltaV I/O subsystem make rapid installation easy. Increases productivity Easy to use Has the flexibility to meet your needs Introduction The MD
Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com
Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer
Engineers Edge, LLC PDH & Professional Training
510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 Engineers Edge, LLC PDH & Professional Training Copyright, All Rights Reserved Engineers Edge, LLC An Introduction to Interior
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket
Data Center Management
Data Center Management How Cisco IT Operates, Manages, and Protects Its Data Center A Cisco on Cisco Case Study: Inside Cisco IT 1 Overview The Cisco IT Operations Data Center on the San Jose, California
Specifying a Variable Frequency Drive s
Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable
SECTION 13421 PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL. 1.01 Summary. A. Section Includes:
SECTION 13421 PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL 1.01 Summary A. Section Includes: 1. The ISS shall furnish all labor, materials, equipment, services and incidentals
White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5
White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code June 2015 Revision 1.5 Shalhevet Bar-Asher; SolarEdge Technologies, Inc. Bill Brooks, PE; Brooks Engineering LLC
4.0 UPS dedicated to ICT for unmatched energy savings
4.0 UPS dedicated to ICT for unmatched energy savings Introducing UPSaver by Borri, a new modular UPS series for the ICT industry, totally configurable, quickly scalable, with high efficiency and low TCO.
Electrical Engineering
Electrical Engineering Trust our people. R eady is a professional engineering firm with highlyqualified electrical and controls personnel focused on providing solutions to meet your specific needs. Ready
Three-phase AC circuits
Three-phase AC circuits This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit http://creativecommons.org/licenses/by/1.0/,
CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING
PART 1-GENERAL 1.01 DESCRIPTION A. This specification is to cover a complete Variable Frequency motor Drive (VFD) consisting of a pulse width modulated (PWM) inverter designed for use on a standard NEMA
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings
*** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not
ST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY
The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY PowerGate - Cost effective solutions for F 1 Horsepower Rating 001 1-40 HP (208V) 075 1-75 HP (480V) Input Voltage 2V 208-240V 4V 380-480V Disconnect
Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management
Energy Depot GmbH Delivering Solutions for Energy Management PRODUCT AND APPLICATION GUIDE Total Monitoring Solution for PV SOLAR LOGGER & ANALYSIS DC STRING MONITORING Residential Comprehensive Solar
Charger Output AC Ripple Voltage and the affect on VRLA batteries
TECHNICAL BULLETIN 41-2131 Charger Output AC Ripple Voltage and the affect on VRLA batteries Please Note: The information in this technical bulletin was developed for C&D Dynasty 12 Volt VRLA products.
High-Efficiency AC Power Distribution for Data Centers
High-Efficiency AC Power Distribution for Data Centers White Paper 128 Revision 2 by Neil Rasmussen > Executive summary The use of 240 volt power distribution for data centers saves floor space, simplifies
IRRIGATION PUMPING Table of Contents - Section 900
IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
Sample - No Commercial Use
COMPLETE REVISION October 2010 Electrical PIP ELSSG01 Design and Fabrication of Low-Voltage Metal-Enclosed AC Power Circuit Breaker Switchgear PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort
Cable/Conduit Conversion
Cable/Conduit Conversion Busway can be used in many applications where cable and conduit are more commonly used. The question arises, Why use busway instead of conventional cable and conduit? Benefits
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
MCC Ratings. Voltage Rating
MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control
7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
NXL Series Inverters. HVAC Inverters made simple
NXL Series Inverters HVAC Inverters made simple Honeywell s Voice Of the Customer process unveils a range of requirements expressed by specifiers and installers, that are ideally covered by the NXL inverter
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
S-series Mass Connection Solutions
DeltaV Distributed Control System Product Data Sheet March 2015 S-series Mass Connection Solutions Fast, easy and error-free cabinet wiring Modular design, improves reliability Lowers overall termination
HM-W536 Install Guide
HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.
Power Plant Electrical Distribution Systems
PDH Course E184 Power Plant Electrical Distribution Systems Gary W Castleberry, PE 2008 PDH Center 2410 Dakota Lakes Drive Herndon, VA 20171-2995 Phone: 703-478-6833 Fax: 703-481-9535 www.pdhcenter.com
BU Control Technologies, Decathlon TM Product Overview. ABB in the Data Center Overview
BU Control Technologies, Decathlon TM Product Overview ABB in the Data Center Overview Introduction to ABB ABB is a global leader in power and automation technologies that enable utility and industrial
Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity
Proper Application of 415V Systems in North American Data Centers A White Paper from the Experts in Business-Critical Continuity Introduction Increasing pressure to reduce operating expenses and be more
Whitepaper Modular Integration of Process Equipment Packages for Oil and Gas Facilities
Whitepaper Modular Integration of Process Equipment Packages for Oil and Gas Facilities Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada Abstract An integrated design approach to a modular
Alain Nifenecker - General Electric Manager Controls Engineering
GE Energy Benefits of Integrating a Single Plant-Wide Control System Into a Standard Plant Design Philosophy Authors: Luis Cerrada Duque - Empresarios Agrupados Director of I&C Department Charles Weidner
Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC
TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while
Application Station Software Suite
February 2016 Page 1 All you need to run custom DeltaV applications is available on the Application Station. Seamlessly integrates your DeltaV data with the rest of your enterprise Includes the DeltaV
HVAC Processes. Lecture 7
HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump
H.V.A.C. Design Plumbing Design
H.V.A.C. Design H.V.A.C. Design Mira Costa College Arts Complex CP Upgrade 1. PART 1 GENERAL 1.1. DESCRIPTION SECTION 23 09 00 HVAC INSTRUMENTATION AND CONTROL 2. PART 2 - PRODUCTS 2.1. Materials