Technical description For a duct cable Containing enhanced standard single mode fibers

Similar documents
ESPECIFICACIÓN DE PRODUCTO

home site map help ECMS Project: Standard / Federal Oversight Advertised

Fibre optic cables MDIC LSZH

144Fibre SM (G.652) Loose Tube Micro Lite Duct Optical Fibre Cable PRODUCT INFORMATION

FIBER-OPTIC CABLES LWL-KABEL

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.

Fibre Optic Indoor/Outdoor Cable

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

GOSN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits

FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER

OPTICAL FIBER CABLES

DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS)

Optical Fibers Fiber Optic Cables Indoor/Outdoor

GOSB. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits

SINGLE MODE OPTICAL FIBER CABLE

SECTION 680 FIBER OPTIC CABLE DESCRIPTION

SINGLE MODE OPTICAL FIBER FTTH CABLE

Fibre Optic Cable. Catalogue.

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

P URCHASING D IVISION

Fiber Optic Specifications

P URCHASING D IVISION

INTERNATIONAL TELECOMMUNICATION UNION #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43

Discontinued. Volition. Fiber Optic Cable. 3Innovation

ALL-DIELECTRIC LOOSE TUBE FIBER OPTIC CABLE

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

Fiber Optic Cordage. Interconnect A Furukawa Company. Product Description. Why OFS Interconnect Cordage?

Types of Optic Cable andApplications

Fiber Optics: Fiber Basics

Radiation-Resistant Single-Mode Optical Fibers

TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH

MacArtney Underwater Cables - In stock

Design of Ultra-High-Density 2000-Optical Fiber Cable with Pliable 8-fiber Ribbons for Underground Deployment

MV CABLE TYPE C

VIPERFLEX ELECTRIC CABLE

200-Micron Single-Mode Fiber Enables New Cable Designs Copyright 2014 OFS FITEL, LLC

Properties and Potential Applications of a Bend Optimised Singlemode Optical Fibre

Communication, Signal & Data Cables

FIBER OPTIC Cables. Cable for Indoor and Outdoor & Hybrid & Marine fiber optic cables

CONFLEX ELECTRIC CABLE

Attenuation: Bending Loss

Fiber Optic Cable Products. Leading Solution

Festoon 715 P PUR cable for flexible application in festoon systems

288 Fiber Ultra-High Fiber Density Micro-Duct Cable with Extreme Operating Performance

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

MICROCABLES. A complete vision of your connectivity needs. Catalogue

Microbend evaluation of selected G652D & G657 fibers and ribbons before cabling

Cable Preparation and Pulling Procedure Best Practices for Fiber Optic Indoor Tight-Buffered Cable

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES

Company and Product Presentation

FACT OPTICAL DISTRIBUTION FRAME SYSTEM

OFS AllWave Zero Water Peak (ZWP) single-mode

Industry solutions: Broad cast

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

Fiber Optic Cable

SECTION FIBER OPTIC CABLE AND ACCESSORIES

OPTICAL FIBRE CABLE APPLICATIONS GUIDELINES

CHARACTERISTICS AND ADVANTAGES OF OPTICAL FIBER CABLES

SECTION COMMUNICATIONS OPTICAL FIBER OSP CABLING

SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS

C A B L E P R O T E C T I O N

Flexible cables for submersible products

Broadcast and Commercial AV Cabling MASTER CATALOG

B05: Cable protection and sheathing

Coats Fibre Optics RIPCORDS BINDERS STRENGTH MEMBERS WATER BLOCKS.

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

Lecture 3: Fibre Optics

APR 2016 Rev M

Outside Telephone Cable

Effect of ageing conditions on performance properties of selected commercial fibers

Fault analysis for optical cables

BELFLOW SERIESS FIBER DISTRIBUTION FIBER DISTRIBUTION BELFLOW IS A BOF (BLOWING OF FIBER) SYSTEM DEVELOPED FROM BELCONN.

Flygt flexible cables

Configuration RJ-45 (IEC ) 6-7. Categories and NEW terms EN , ISO/IEC De-embedded Re-embedded 14-15

Cable Preparation Best Practices for Fiber Optic Indoor/Outdoor Stranded Loose Tube Cable

FIBER-OPTIC CABLES LWL-KABEL

UGVCL/SP/591/11KV HT AB CABLE

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

5.2. Overview. The better method to install solderless compression connectors on power cable

EXAMPLE OF RELEVANT STANDARDS

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

HUS-V Screw anchor. HUS-V Screw anchor. Basic loading data (for a single anchor) Mean ultimate resistance

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

SPECIALTY FIBER OPTIC CABLE. Downhole Subsea Sensing Equipment

KNOW YOUR OPTIONS: 230 KV POWER CABLES

Hard Clad Silica (Standard OH) Radius

BOTDR Measurement Techniques and Brillouin Backscatter Characteristics of Corning Single-Mode Optical Fibers

We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

How To Read A Pipe From A Sensor

with coloured cores and overall copper screen UL/CSA... 17

Model CS 64 Mini-DIN Cable and Adaptor

The Conversion Technology Experts. Fiber Optics Basics

COAX Cables Radio Frequency Cables

Reliable, Consistent, Quality

Section kv Power Cables

Transcription:

Technical description For a duct cable Containing enhanced standard single mode fibers Our proposed offer is in full compliance with ITU-T G.652D and annexes. The offered cable is fully compliant to the relevant IEC specifications, especially IEC 60793-1,2, IEC 60794-3. A technical comment is prepared for optical fiber cables having the following characteristics: Cable design: - 12, 24, 36, 48, 60, 72, 96, 144, 192 SMF 28-e -fibers with reduced OH- peak. - Operating wavelength at 1310 nm and 1550 nm. - Non metallic strength and anti-buckling element. - Loose buffer tubes SZ-stranded. - Dry cable core by swellable elements. - Non metallic strength members over the core. - Outer PE-jacket. - Suitable as: fully dielectric duct cable. Cable type: A-DQ(ZN)2Y 2x6 E9/125 0.36F3.5 + 0.22H18 LG A-DQ(ZN)2Y 4x6 E9/125 0.36F3.5 + 0.22H18 LG A-DQ(ZN)2Y 3x12 E9/125 0.36F3.5 + 0.22H18 LG A-DQ(ZN)2Y 4x12 E9/125 0.36F3.5 + 0.22H18 LG A-DQ(ZN)2Y 5x12 E9/125 0.36F3.5 + 0.22H18 LG A-DQ(ZN)2Y 6x12 E9/125 0.36F3.5 + 0.22H18 LG A-DQ(ZN)2Y 8x12 E9/125 0.36F3.5 + 0.22H18 LG A-DQ(ZN)2Y 12x12 E9/125 0.36F3.5 + 0.22H18 LG A-DQ(ZN)2Y 16x12 E9/125 0.36F3.5 + 0.22H18 LG 1/10

Table of contents Optical and mechanical characteristics of a enhanced standard single mode fiber... 3 Core material... 3 Cladding material... 3 Type of primary coating... 3 Dimension of primary coating...3 Mechanical characteristics of the primary coating... 4 Mechanical characteristics of fiber...4 Loose buffer tube technique... 4 Reverse lay (SZ) stranding... 4 Cable core... 4 Cable make up... 5 Technical characteristics:... 6 Cable Cross-section... 7 2/10

Optical and mechanical characteristics of an enhanced single mode fiber SMF 28e - low water peak fiber - Mode field diameter (1310 nm): 9.2 µm ± 0.4 µm Mode field diameter (1550 nm): 10.4 µm ± 0.8 µm Cladding diameter: 125 µm ± 0.7 µm Mode field concentricity error: 0.5 µm Cladding non circularity: 1 % Refractive index profile: step Design: matched cladding Effective group index of refraction N eff (at 1310nm): 1.4677 Effective group index of refraction N eff (at 1550nm): 1.4682 Cut off wavelength of cabled fiber: 1260 nm Coating diameter: 245 µm ± 5 µm Attenuation at 1310 nm *): Attenuation at 1383 nm (OH-peak): Attenuation at 1550 nm *): Dispersion in the range 1288 to 1339 nm: Dispersion at 1550 nm: *) measured values 0.36 db/km 0.36 db/km 0.22 db/km 3.5 ps/nm x km 18 ps/nm x km Core material The core of the optical fiber, with a higher refractive index compared to the cladding, is made of SiO 2 (Silicon dioxide) doped with GeO 2 (Germanium dioxide). Cladding material The cladding of the optical fiber is made of SiO 2 (Silicon dioxide). Type of primary coating The primary coating is made of an UV-curable acrylate. It is applied in two layers, each of a different Young's modulus. The inner layer is somewhat softer than the outer one. This make-up protects the fiber against microbending losses and against abrasion. Fiber colour coding: fiber-# 1 : red fiber-# 7 : grey fiber-# 2 : green fiber-# 8 : violet fiber-# 3 : yellow fiber-# 9 : black fiber-# 4 : blue fiber-# 10 : orange fiber-# 5 : brown fiber-# 11 : turquoise fiber-# 6 : white fiber-# 12 : pink Dimension of primary coating The dimension of the primary coating is 245 µm ± 5 µm. 3/10

Mechanical characteristics of the primary coating The primary coating is easily strippable by means of a mechanical stripping tool. No chemicals are required. Mechanical characteristics of fiber Proof test stress: 8 N for 1 second ; strain: 1 %. Breaking strength of fiber at least: 150 N/mm². Loose buffer tube technique In the loose buffer tube technique the primary coated fiber is accommodated in a secondary coating, called buffer tube. The buffer may contain one or more fibers, which are loosely laying in the tube. The tube is filled with a non-hygroscope, non-nutritive fungus, electrically non-conductive, homogenous gel in order to prevent water penetration and migration. The gel will be free from dirt and foreign matter and is easily removable with conventional non-toxic solvents. The loose buffer technique is also coping best to temperature induced contractions or dilatations of the cable. The structure also provides good protection against transverse compression. As a result the whole cable construction is, within a wide range, insensitive to external influences. Reverse lay (SZ) stranding The elements (loose buffer tubes and if necessary filling elements) are stranded around a central member according to the reverse lay method, which means, that the direction of stranding reverses after a predetermined number of revolutions. At the reverse point the elements are laying parallel to the axis of the cable. A binder is wound around the elements in order to retain them in the proper position. Cable core Around a dielectric central member made of fiber reinforced plastic,buffer tubes and filling elements are stranded to form the core of the cable. The central member serving mainly as anti-buckling element will be coated with a PE-jacket, if this is required to obtain the correct stranding radius. The buffer tubes contain up to 12 fibers. Colour coding: buffer tube-# 1 : red buffer tube-# 7 : grey up to 144 fibers buffer tube-# 2 : green buffer tube-# 8 : violet buffer tube-# 3 : yellow buffer tube-# 9 : black buffer tube-# 4 : blue buffer tube-# 10 : orange buffer tube-# 5 : brown buffer tube-# 11 : turquoise buffer tube-# 6 : white buffer tube-# 12 : pink 4/10

Colour coding: buffer tube-# 1 : red buffer tube-# 4 : blue 1 st layer, 192 fibers buffer tube-# 2 : green filler buffer tube-# 3 : yellow filler Colour coding: buffer tube-# 1 : red buffer tube-# 7 : grey 2 nd layer, 192 fibers buffer tube-# 2 : green buffer tube-# 8 : violet buffer tube-# 3 : yellow buffer tube-# 9 : black buffer tube-# 4 : blue buffer tube-# 10 : orange buffer tube-# 5 : brown buffer tube-# 11 : turquoise buffer tube-# 6 : white buffer tube-# 12 : pink Due to stranding of the buffers an overlength of about 0.3 to 0.5 % is produced. (The overlength depends on stranding radius, tube diameter and lay length). That means, if a tensile force is applied to the cable and hence to the core, an elongation in a wide range will not result in fiber-strain and no attenuation increase is observed. Cable make up Waterswellable elements are placed over the cable core in order to block any possible water ingress. Around the cable core aramid yarns will be wrapped to provide the required tensile strength. Finally an outer PE-jacket is extruded. The polymer shall contain carbon black for ultraviolet light protection and shall not promote the growth of fungus and shall be free of holes, splits and blisters. 5/10

Technical characteristics: Cable type : A-DQ(ZN)2Y fiber count 12, 24, 36, 96 48, 60, 72 Diameter (D) approx. [mm] 11,5 13,3 Weight approx. [kg/km] 98 129 Min. bending radius - during installation [mm] 230 265 - installed [mm] 170 200 Tensile strength - short term (during installation), [N] 1500 2000 - long term (installed) [N] 900 1100 Compressive stress/crush [N/10cm] 2500 2500 (Attenuation increase fully reversible) Impact resistance (E= 30 Nm, r = 300 mm) [impacts] 1 1 (Attenuation increase fully reversible) Operating temperature range [ C] -30...+70-30...+70 Installation temperature range [ C] -5...+50-5...+50 Cable type : A-DQ(ZN)2Y fiber count 144 192 Diameter (D) approx. [mm] 17.0 17.2 Weight approx. [kg/km] 213 207 Min. bending radius - during installation [mm] 340 350 - installed [mm] 255 265 Tensile strength - short term (during installation), [N] 3300 3300 - long term (installed) [N] 1200 1200 Compressive stress/crush [N/10cm] 2500 2500 (Attenuation increase fully reversible) Impact resistance (E= 30 Nm, r = 300 mm) [impacts] 1 1 (Attenuation increase fully reversible) Operating temperature range [ C] -30...+70-30...+70 Installation temperature range [ C] -5...+50-5...+50 6/10

Cable Cross-section Dielectric central strength and anti-buckling element Filled buffer tube with up to 12 singlemode fibers Outer PE-jacket nom. thickness 1,8 mm Tensile element Rip cord Water swellable element Outer diameter approx.: Weight approx.: Max. tensile strength: 11,5 mm 98 kg/km 1500 N Cable type: A-DQ(ZN)2Y 2x6 E9/125 0.36F3.5 + 0.22H18 LG A-DQ(ZN)2Y 4x6 E9/125 0.36F3.5 + 0.22H18 LG A-DQ(ZN)2Y 3x12 E9/125 0.36F3.5 + 0.22H18 LG A-DQ(ZN)2Y 4x12 E9/125 0.36F3.5 + 0.22H18 LG A-DQ(ZN)2Y 5x12 E9/125 0.36F3.5 + 0.22H18 LG A-DQ(ZN)2Y 6x12 E9/125 0.36F3.5 + 0.22H18 LG Technical comment: 05-12-13 A-DQ(ZN)2Y 12,24,36,48,60,72,96,144,196 E9 MATAV PA 02-7662 CCS reserves the right to improve, enhance, and modify the features and specifications of CCS s products without prior notification. The information in this data sheet has been reproduced in good faith and is accurate, to the best of CCS s knowledge, at the time of printing. However, CCS makes no warranty as to, and will not be liably on any basis for, the information contained within this data sheet. 7/10

Cable Cross-section Filled buffer tube with 12 singlemode fibers Dielectric central strength and anti-buckling element Outer PE-jacket nom. thickness 1,8 mm Tensile element PE covering Swellable elements Rip cord Outer diameter approx.: Weight approx.: Max. tensile strength: 13,3 mm 129 kg/km 2000 N Cable type: A-DQ(ZN)2Y 8x12 E9/125 0.36F3.5 + 0.22H18 LG Archiv: CCS EMEA AE Datenblatt: 05-12-13 A-DQ(ZN)2Y 12,24,36,48,60,72,96,144,196 E9 MATAV PA 02-7662 CCS behält sich das Recht vor, ohne vorherige Ankündigung CCS Produkte zu verbessern, zu erweitern oder in sonstiger Weise zu modifizieren. Dadurch können sich insbesondere auch Daten und sonstige Angaben zu den Produkten ändern. Ein Rechtsanspruch auf die Lieferung eines bestimmten Produkts mit genau bestimmten Spezifikationen entsteht erst mit Annahme einer verbindlichen Bestellung durch CCS. 8/10

Cable Cross-section Dielectric central strength and anti-buckling element Filled buffer tube with 12 singlemode fibers Outer PE-jacket nom. thickness 2.0 mm Tensile element Waterswellable elements Rip cord Outer diameter approx.: Weight approx.: Max. tensile strength: 17.0 mm 213 kg/km 3300 N Cable type: A-DQ(ZN)2Y 12x12 E9/125 0.36F3.5 + 0.22H18 LG Archiv: CCS EMEA AE Datenblatt: 05-12-13 A-DQ(ZN)2Y 12,24,36,48,60,72,96,144,196 E9 MATAV PA 02-7662 CCS behält sich das Recht vor, ohne vorherige Ankündigung CCS Produkte zu verbessern, zu erweitern oder in sonstiger Weise zu modifizieren. Dadurch können sich insbesondere auch Daten und sonstige Angaben zu den Produkten ändern. Ein Rechtsanspruch auf die Lieferung eines bestimmten Produkts mit genau bestimmten Spezifikationen entsteht erst mit Annahme einer verbindlichen Bestellung durch CCS. 9/10

Cable Cross-section Dielectric central strength and anti-buckling element Filled buffer tube with 12 singlemode fibers Filling element Outer PE-jacket nom. thickness 2.0 mm Tensile element Rip cord Waterswellable elements Outer diameter approx.: Weight approx.: Max. tensile strength: 17.2 mm 207 kg/km 3300 N Cable type: A-DQ(ZN)2Y 16x12 E9/125 0.36F3.5 + 0.22H18 LG Archiv: CCS EMEA AE Datenblatt: 05-12-13 A-DQ(ZN)2Y 12,24,36,48,60,72,96,144,196 E9 MATAV PA 02-7662 CCS behält sich das Recht vor, ohne vorherige Ankündigung CCS Produkte zu verbessern, zu erweitern oder in sonstiger Weise zu modifizieren. Dadurch können sich insbesondere auch Daten und sonstige Angaben zu den Produkten ändern. Ein Rechtsanspruch auf die Lieferung eines bestimmten Produkts mit genau bestimmten Spezifikationen entsteht erst mit Annahme einer verbindlichen Bestellung durch CCS. 10/10