FACT OPTICAL DISTRIBUTION FRAME SYSTEM
|
|
- Virginia Chandler
- 7 years ago
- Views:
Transcription
1 Fiber Connectivity for Splice/Patch and Patch/Patch For almost 30 years, CommScope has led the industry with solutions such as FIST fiber management system, providing a system of fiber management from the central office through the customer premises. Now, we continue that leadership with the introduction of the FACT ODF system, enabling faster and easier installation in a high density environment. The toolless system approach and the high level of modularity guarantee an easy migration path towards new connectivity platforms and expansion of existing central office sites. FACT modules support full patch and/or splice-patch functions within a rack environment. Trays within the element can be configured with adapters, splicing and passive optical components. Trays are staggered for easy fiber routing and access to connectors.currently available, the FACT standard version integrates into a current partially or non-equipped FIST-GR2/3 frame or lineup. Features Patching, using patch cords, connectorized breakout or intrafacility cables Splicing loose tube, non-connectorized intrafacility or breakout cables to pigtails and patching these pigtails to patch cords Supports integration of passive optical splitters and wavelength division multiplexers Various connector/adapter types possible Enhanced modularity created by stacking four elements together in a 3HU grouping Full patching capability on the elements and between elements in one module and across modules Use of connectorized cables allows repair of pigtails Easy identification of each fiber Kits available to attach cables at the side of the elements Full wrap-around solution accessible from the front to guide fibers and pigtail Can be installed in FIST racks and metric (ETSI) rack sizes FACT elements and modules are shipped with the maximum number of trays already installed. 1
2 Benefits of advanced element patching Easy: Full front access and non-moving fiber during element manipulation Fast: Toolless scalable system Clean: Both sides easily accessible for cleaning adapters Safe: Laser light oriented perpendicularly to the operator Accessible: Guaranteed full front access at both sides of connection Secure: Because of their position in the trays, connectors are better protected than in some front facing patch shelves Manipulation of patch cords does not cause transient losses Reconnection to other positions in the same tray or shelf does not result in uncontrolled overlengths Bend controls guide and protect the pigtail cable and ensure controlled cable routing Visible: Patch cords do not hamper access or visibility of ports Dimensions of FACT elements Height in mm Width in mm Depth in mm Number of standard/ small-form-factor adapters Standard (retrofit in FIST-GR3 frames) /48 Ordering FACT modules Element colors: Orange (RAL 2011) and grey (RAL 7035) Elements are always ordered fully loaded For a list of accessories and consumables, please refer to the FACT accessories ordering guide Elements are configured with single adapters* Cable construction (the number of fibers per cable) will determine the number and combination of elements to be ordered Depending on the cable s fiber count, at least one of the total number required to support that number of fibers must be releasable (equipped with a latch that allows a set/combination of elements to be removed from the rack) Elements support most common cable constructions (loose tube, central core, IFC) Four (4) elements equal 3HU (125mm) * For FACT elements with adapter packs, please contact your local sales representative. 2
3 Cable fiber count SC connectors/adapters LC connectors/adapters 24 SC connectors per element (1) 48 LC connectors per element (2) Number of FCEs Height Units Number of FCEs Height Units 24 1 Fits 1HU 1* Fits 1HU 48 2 Fits 2HU 1 Fits 1HU 72 3 Fits 3HU 2** Fits 2HU 96 4 Fits 3HU 2 Fits 2HU Fits 5HU 3 Fits 3HU Fits 6HU 4 Fits 3HU Fits 5HU 1 SC connectors with up to 2.4mm patch cords 2 LC connectors with up to 1.8mm patch cords * Element ships with 2 trays, each with 12 LC adapters (24 LC connections); 48 LC connections in total. Unused tray may be discarded or used for future growth. ** Each elements ship with 2 trays, each with 12 LC adapters (24 LC connections). 96 LC connections in total. Unused trays may be discarded or used for future growth. 3
4 FACT STANDARD SIZE Ordered for retrofit into a current partially or non-equipped FIST-GR2/3 frame or lineup. 4
5 FACT Module - Standard Size Patch only. No Cable. Standard kit includes: Trumpets Hook and loop fasteners Back plates ordered separately. Size of back plate defined by port/fiber count. See page 8 for information. FACT - S -XXX XX AA - 0 NN Port count position (SC only) position position (SC only) position position position position (LC only) Adaptor type Single adapters S1 SC/UPC S2 SC/APC 8 L1 LC/UPC L2 LC/APC E9 E For FACT elements with adapter packs, please contact your local sales representative. 5
6 FACT Module - Standard Size Splice/Patch. No Cable. Standard kit includes: Trumpets Hook and loop fasteners Back plates ordered separately. Size of back plate defined by port/fiber count. See page 8 for information. Cable attachment kits ordered separately. Attachment size defined by cable size and fiber type. See pages 9 and 10 for information. Port count FACT - S -XXX XX XX - 0 NN Tray Option position (SC only) position position (SC only) position position position position (LC only) Adapter type Single adapters Standard (Grade C) Superior (Grade B) SC/UPC S1 - SC/APC 8 S2 SG SC/APC 9 S3 - LC/UPC L1 LF LC/APC L2 LG E E9 - For FACT elements with adapter packs, please contact your local sales representative. Standard adapters Right of shelf (1) Left of shelf (2) Adapters; SMOUV splice protector; no fiber (3) AE EA Adapters; ANT splice holder (4) ; no fiber AF FA Connector/adapters; with pigtails and SMOUV splice protector (3) ; fiber from adapters to splice holder, ready for incoming cable Connector/adapters; with pigtails and ANT splice holder (4) ; fiber from adapters to splice holder, ready for incoming cable 1 Patch cords leave shelf to right 2 Patch cords leave shelf to left 3 45 mm SMOUV heat shrink splice protector is included 4 ANT splice holder ONLY; splice protectors must be ordered separately NOTE: Pigtails are installed with DIN IEC color coding. DIN IEC Fiber 1 Red Fiber 7 Brown Fiber 2 Green Fiber 8 Violet Fiber 3 Blue Fiber 9 Aqua Fiber 4 Yellow Fiber 10 Black Fiber 5 White Fiber 11 Orange Fiber 6 Grey Fiber 12 Pink AI AJ IA JA If you want a different color coding, please contact your local sales representative. 6
7 FACT Module - Standard Size Splice/Patch. Pre-cabled. Standard kit includes: Trumpets (pre-installed) Cable attachments (pre-installed) Hook and loop fasteners Back plates ordered separately. Size of back plate defined by port/fiber count. See page 8 for information. Port count position position position position position position position (LC only) Adapter type Single adapters Standard (Grade C) Superior (Grade B) SC/UPC S1 - SC/APC 8 S2 SG SC/APC 9 S3 - FACT - S -XXX XX XX - XX XX Length in meters 0-99 Tray Option 1A MA MB OD OF OG OH Intrafacility cable 12-fiber (no strength member) Micro-distribution breakout cable 8-fiber 12-fiber Loose tube indoor cable 24-fiber 48-fiber 72-fiber 96-fiber For other cable types, please contact your sales representative. LC/UPC L1 LF LC/APC L2 LG E E9 - For FACT elements with adapter packs, please contact your local sales representative. Standard adapters Right of shelf (1) Left of shelf (2) Adapters; SMOUV splice protector; no fiber (3) AE EA Adapters; ANT splice holder (4) ; no fiber AF FA NOTE: Pigtails are installed with DIN IEC color coding. 1 Patch cords leave shelf to right 2 Patch cords leave shelf to left 3 45 mm SMOUV heat shrink splice protector is included 4 ANT splice holder ONLY; splice protectors must be ordered separately DIN IEC Fiber 1 Red Fiber 5 White Fiber 9 Aqua Fiber 2 Green Fiber 6 Grey Fiber 10 Black Fiber 3 Blue Fiber 7 Brown Fiber 11 Orange Fiber 4 Yellow Fiber 8 Violet Fiber 12 Pink If you want a different color coding, please contact your local sales representative. 7
8 Back plates for standard size FACT elements and modules Description Ordering Number Back plates Allow placement of FACT STANDARD size elements or modules in FIST-GR3 Fits 1 HU; mounts 1 standard size FACT element (2) cage nuts (2) bolts (2) washers (2) single U-shape FACT brackets FACT-BPLATE-1E-S Fits 2 HU; mounts 2 standard size FACT elements (4) cage nuts (4) bolts (4) washers (2) double U-shape FACT brackets Equal to 3 HU; mounts 4 standard size FACT elements (1 FACT module) (4) cage nuts (4) bolts (4) washers (4) double U-shape FACT brackets FACT-BPLATE-2E-S FACT-BPLATE-4E-S NOTE: When an empty FIST-GR3 rack is to be fully loaded with FACT elements, a kit (FACT-BPLATE-28E-S) is available. This one piece plate accommodates 28 FCE and occupies one half of the FIST-GR3 (2.2m) rack. Please contact your local sales representative for more information. Cable fiber count SC connectors/adapters 24 SC connectors per element LC connectors/adapters 48 LC connectors per element Number of FCEs Height Units Number of back plates Number of FCEs Height Units Number of back plates 24 1 Fits 1HU (1) 1E-S 1 Fits 1HU (1) 1E-S 48 2 Fits 2HU (1) 2E-S 1 Fits 1HU (1) 1E-S 72 3 Fits 3HU (1) 1E-S + (1) 2E-S 2 Fits 2HU (1) 2E-S 96 4 Fits 3HU (1) 4E-S 2 Fits 2HU (1) 2E-S Fits 5HU (1) 2E-S + (1) 4E-S 3 Fits 3HU (1) 1E-S + (1) 2E-S Fits 6HU (2) 4E-S 4 Fits 3HU (1) 4E-S Fits 5HU (1) 2E-S (1) 4E-S 8
9 Cable attachment kits for standard size FACT elements and modules Description Ordering Number Cable bracket kits 250 μ cable For cable diameters up to 8.5mm* Occupies 1 FACT element Single cable attachment sub-assemblies Strength members 250 μ routing components Plastic covers 250 μ overtubing Overtubing fixation devices Spiral tube protection pieces Tie wraps Foam strips FACT-CACC-SMALL-PF For cable diameters from 8.5mm to 15mm** Occupies 1 FACT element Single cable attachment sub-assembly Strength member 250 μ routing components Plastic cover 250 μ overtubing Spiral tube protection pieces Tie wraps Foam strips FACT-CACC-MEDIUM-PF Cable bracket kits 900 μ cable For cable diameters up to 8.5mm* Occupies 1 FACT element Single cable attachment sub-assemblies Strength members 900 μ routing components Plastic covers Fiber fixation devices Spiral tube protection pieces Tie wraps Foam strips FACT-CACC-SMALL-SF For cable diameters from 8.5mm to 15mm** Occupies 1 FACT element Single cable attachment sub-assemblies Strength members 900 μ routing components Plastic covers Fiber fixation devices Spiral tube protection pieces Tie wraps Foam strips FACT-CACC-MEDIUM-SF * Note: Cable should be flexible and allow minimum bend radius of 75 mm. Cable attachment fits corrugated tube 10mm outer diameter ** Note: Cable should be flexible and allow minimum bend radius of 75 mm. Cable attachment fits corrugated tube 16mm outer diameter 9
10 Cable fiber count Number of FCEs SC connectors/adapters 24 SC connectors per element Height Units Number of cable attachment kits Number of FCEs LC connectors/adapters 48 LC connectors per element Height Units Number of cable attachment kits SMALL MEDIUM SMALL MEDIUM 24 1 Fits 1HU Fits 2HU Fits 1HU Fits 3HU Fits 2HU Fits 3HU Fits 2HU Fits 5HU Fits 3HU Fits 6HU Fits 3HU Fits 5HU Visit our website or contact your local CommScope representative for more information CommScope, Inc. All rights reserved. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. PS (10/15)
Reliable, Consistent, Quality
Reliable, Consistent, Quality 1-877-320-3143 www.fibertronics.com Reliable, Consistent, Quality Welcome To Fibertronics Inc. Reliability, consistency, and quality is what we put behind every Fiber optic
More informationFCS-FCT-FCP Housings and Connector Panels. InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2
Product Family: Product: Fibre: LANscape Hardware Solutions FCS-FCT-FCP Housings and Connector Panels InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2 Applications Corning Cable
More informationLANC Fibre Patch Panel Solution
features and benefits Modular front with interchangeable fibre optic adapter modules Quick mount feature (teardrop design) Port numbers printed above and below adapter modules High-density using LC connectivity
More information1U Multi-Function Fibre Enclosure
FEATURES AND SPECIFICATIONS Features and Benefits The is a configurable rack mount unit for storing and terminating incoming fibre cable. The fibre enclosure has been designed to accommodate various termination
More informationInstaPATCH ZERO Solution Guide
SYSTIMAX Solutions InstaPATCH ZERO Solution Guide Rapid Server Deployment and Change Management North, South and Central Americas 1 As data centers face ever-increasing IT demands, growth demands and evolving
More informationCabinets 101: Configuring A Network Or Server Cabinet
Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What
More informationFiberGuide Fiber Management Systems. 4th Edition
FiberGuide Fiber Management Systems 4th Edition Table of Contents Introduction Introduction...1 A Variety of Solutions...2 Innovative Products...3 Features and Benefits... 4 Applications Combining System
More informationLSA-PLUS Series 2 Connection and Disconnection Modules and Accessories
LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially
More informationFTTX Solutions FDH 3000 Cross-Connect
TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions
More informationETD Fiber Optic Products
ETD Fiber Optic Products ETD manufactures and supplies a wide range of passive fiber optic components and solutions for the European Data, Telecom and FTTX environment. ETD has worked in the Fiber Optic
More informationPanduit 28 AWG Patch Cords Installation Guideline
Panduit 28 AWG Installation Guideline Introduction Panduit is a leading supplier of Structured Cabling Systems and Unified Physical Infrastructure. Panduit solutions enable the physical infrastructure
More informationE Series. E Series. Category 6 and 5e. Features
E Series Category 6 and 5e CommScope, world leader in copper and fiber connectivity, offers the E Series product line as the ideal solution to all your infrastructure needs for safe and reliable data transmission.
More informationFaster Method for Connecting Customers in the Colocation Data Center
Faster Method for Connecting Customers in the Colocation Data Center The increased demand for datacenter space is creating both opportunities and challenges for providers of colocation space. Among these
More informationHP 16/18-Port Cable Management Kit Installation Guide
HP 16/18-Port Cable Management Kit Installation Guide Abstract This document describes how to attach the HP 16 Port or 18 Port Cable Management Kit to an HP rack. The cable management bracket is designed
More information7.4 3M No Polish Connector
Cap Fibre Splice Element Description 3M No Polish Connector (NPC) enables fast, on-site installation of 250μm and 900μm connections utilizing a one piece, pre-assembled design. The SC compatible connector
More informationPlug - Type (Male/Female) Attenuators CAA series Singlemode
Plug - Type (Male/Female) Attenuators CAA series Singlemode Description: The plug-type singlemode attenuators are used directly on the ends of fiber optic jumpers prior to installation in adapters. These
More informationCable Assembly Solutions at the Speed of Light
Cable Assembly Solutions at the Speed of Light Peggy Kovling ACI Founder Peggy Kovling credits her extensive knowledge of the cable business, along with her abilities in customer relationship management,
More informationDIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).
DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute
More informationCabinet V800 V800 CABINETS
V800 Cabinet Siemon s V800 cabinets provide a robust, cost-effective enclosure solution that provides valuable Zero-U space on each side of the equipment rails for cable management, PDU mounting or connectivity
More informationFiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications
Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications Topics! Understanding Fiber Types! Powering your Remotes via Composite Fiber! Fiber Design
More informationIT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
More informationPlug & Play Universal Systems
Plug & Play Universal Systems A LANscape Pretium Plug & Play Universal Systems for Data Centers and Storage Area Networks (SANs) Corning Plug & Play universal systems create a fiber optic tip-to-tip solution
More informationUniprise Solutions. Information Security Network Solutions
Uniprise Solutions Information Security Network Solutions Information Security Network Solutions Companies today face the challenges of maintaining data security throughout the enterprise. Network managers
More informationPretium EDGE HD Solutions
Pretium EDGE HD Solutions for Enterprise Data Centers and Storage Area Networks Corning Cable Systems Pretium EDGE HD Solutions create a fiber optic tip-to-tip solution for Data Centers and Storage Area
More informationWall Mounted Products
Metallic Indoor PK Termination Boxes Prysmian Part Numbers: see below Metallic PK Termination Boxes are designed for the termination, branching and distribution of fibre optic cables in telecommunication,
More informationOpticom Fiber Optic Splice Module
Opticom Fiber Optic Splice Module Part Numbers: FOSMF, FOSMM Panduit Corp. 2014 INSTALLATION INSTRUCTIONS FOSMF in open position FOSMM in open position FOSMF OR FOSMM in closed position Contents: (1) SPLICE
More informationFOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future
CORDS & CABLE ASSEMBLIES Standard Simplex/Duplex Patch Cords Overview: FOCONEC supplies full series of standard simplex, duplex patch cords or pigtails, designed for interconnection or cross connection
More informationAbout the BitStorm 6051 POTS Splitter
BitStorm 6051 Installation Instructions Document Number 6051-A2-GZ40-10 July 2002 About the BitStorm 6051 The BitStorm system enables simultaneous high-speed digital data access and analog voice service
More informationPretium Connector Housings
Pretium Connector Housings A LANscape Pretium Solutions Product Applications Main cross connect, intermediate cross connects and telecommunications rooms Rack or equipment cabinet installations Data center
More informationThe migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations
The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations White Paper www.commscope.com Contents Introduction 3 CommScope solution overview 3 InstaPATCH
More informationPolymer Coated Fiber Cable (PCF)
Polymer Coated Fiber Cable (PCF) Panduit has introduced a Polymer Coated Fiber (PCF) to their fiber cable offering available in 50µm and 62.5µm core diameters. Along with this cable having a stronger durability
More informationCoyote popup features
Coyote popup features The Coyote popup display system combines strength, reliablility, and style in a lightweight and easy to use system. It is fully magnetic, making it simple to assemble and disassemble,
More informationCoyote popup features
Coyote popup features The Coyote popup display system combines strength, reliablility, and style in a lightweight and easy to use system. It is fully magnetic, making it simple to assemble and disassemble,
More informationSECURE Fiber Optic Products
SECURE Fiber Optic Products LC SECURE Fiber Optic Products (Pages 9 and 10) LC SECURE Connectors, Cable Assemblies and Adapters MPO SECURE Fiber Optic Products (Pages 11 and 12) MPO SECURE Cable Assemblies
More informationEXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions
EXPLORE 4-Leg Teaming Table with Screen Share Monitor Display Requirements: your flat panel display must confirm to the following requirements. y With the stand removed, the monitor must not exceed 40
More informationTubing and Accessories
Section 7 Tubing and Accessories Inch Industrial Tubing................................FIT-7-2 Metric Industrial Tubing...............................FIT-7-3 Inch D.O.T. Tubing...................................FIT-7-3
More informationRittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow
More informationManaging High-Density Fiber in the Data Center: Three Real-World Case Studies
Managing High-Density Fiber in the Data Center: Three Real-World Case Studies CHALLENGE In today s data center, fiber optic links have become more vital than ever for transmitting data to and from a large
More informationAlso available OM4. Other specification available on request Approved for Telecom quality standards. Cable colour. Lenght (m) Fiber type.
SC/SC duplex fiber patch cords - OD 3mm/ TELECOM SERRIES SC/SC simplex ARMORED patch cords/ INDUSTRIAL SERRIES SC/SC-DX-1.0 SC/UPC OS2 SM Yellow 1,0 SC/SC-DX-2.0 SC/UPC OS2 SM Yellow 2,0 SC/SC-DX-5.0 SC/UPC
More informationCoyote popup features
Coyote popup features The Coyote popup display system combines strength, reliablility, and style in a lightweight and easy to use system. It is fully magnetic, making it simple to assemble and disassemble,
More informationHP 36-Port InfiniBand Switch Cable Management Kit Installation Guide
HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide HP Part Number: 574412-doc Published: May 2009 Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein
More informationProduct Information 19 / 45HU Data-Center-Rack (Cabinet)
The Rosenberger-OSI Data-Center-Rack has been developed especially for FO patch distributors in Data Centers. In Data Centers the requirement for highest density becomes increasingly more important than
More informationSTATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007
804.01 Description 804.02 General 804.03 Materials 804.04 Fan-Out Kit 804.05 Drop Cable 804.06 Fiber Optic Patch Cord 804.07 Termination Panel 804.08 Fusion Splice 804.09 Fiber Optic Connector 804.10 Splice
More informationLED NarrowStik LED LC-Stik
INSTALLATION & OPERATION MANUAL NASL547/39 NASL847/39 NAS3547/39 NAS3847/39 NarrowStik LCC547/39 LC847/39 LC-Stik LC-STIK NARROWSTIK 3-Up OPTIX TM NARROWSTIK LED NarrowStik LED LC-Stik Contents: Introduction
More information1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:
Washington University in St. Louis Building: Communication Specification: Research Voice/Network/Typical 1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:
More informationTCTC Cabling Specifications
TCTC Cabling Specifications Purpose: To provide a standard specification that will be used for all Tri County Technical College (TCTC) facilities requiring structured cabling installation. Product specifications,
More information4RU High Density Shelf Installation Instructions
4RU High Density Shelf Installation Instructions Table of Contents General Product Information... 1.0 Safety Precautions... 2.0 Tools Required... 3.0 Package Contents... 4.0 Installing the Product Unpacking...
More informationMPO. Fast Fibre Solution for Data Centres
MPO Fast Fibre Solution for Data Centres Benefits The Plug & Play MPO solution of Nexans Cabling Solutions provides a comprehensive line of pre-terminated and pre-tested assemblies to meet the current
More informationDIY Y6. Build Manual V.A 2014
DIY Y6 Build Manual V.A 2014 1 Contents Thanks for purchasing a DIY Y6! These instructions will show you how to assemble a Y6 using the Pixhawk autopilot system and ArduCopter/APM:Copter firmware. If you
More informationOEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
More informationINSTALLATION GUIDE. APPLICATION LENGTH MODEL YR PART # Bestop PART #
INSTALLATION GUIDE APPLICATION LENGTH MODEL YR PART # Bestop PART # Ford Super Duty F-250 / F-350 Regular Cab (48 ) 1999 2007 10-02513-24 75102-01 Ford Super Duty F-250 / F-350 Super Cab (60 ) 1999 2007
More informationFiber-to-the-Home/FTTH
Hands-On Design, Installation, Maintenance & Troubleshooting Active and Passive Optical Networks Course Description This Hands-On 2-day course is designed to provide technicians with Hands-On practical
More informationPatch Cords for Data Center Applications
Applications General use of patch cords includes the interconnection of the optical fiber cable plant with opto-electronic equipment, and/or the cross-connection between cable plant segments. Pigtails
More informationMigration Strategy for 40G and 100G Ethernet over Multimode Fiber
Introduction Migration Strategy for 0G and 00G Ethernet over Multimode Fiber There is a need for increased network bandwidth to meet the global IP traffic demand, which is growing at a rate of 0% per year
More informationProcedure for Cutting and Respooling Fiber Optic Cable
Table of Contents 1. GENERAL 1.1 Improper use of a respooler (Figure 1) can cause damage to a cable jacket or result in wavy fiber in tight buffered cables due to cable crossovers or excessive tensile
More informationInForm Mobile Units. Selection. Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley
Selection Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley Basic mobile unit Basic mobile with vertical profiles Installation options Functional shelf, low Functional shelf, inclinable
More informationFIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER
FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER 1. Applications - Be suitable for the cable of communication,communication device pigtail and the movable connection wire jumper wire - Short and medium distance,
More informationSOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
More informationColocation Rack Secure, Separate Server Hosting and Housing in Data Centers
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required
More informationINSTALLATION INSTRUCTIONS
Rear Vision System Tailgate Handle Camera Mirror Display 2004-2014 Ford F-150 and 2008-2015 Ford Super Duty (Kit part numbers 9002-9521) Kit Contents: Mirror Tailgate Handle with camera and harness Interior
More informationHARTING Ethernet Cabling 8-poles Overview
Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs
More informationDCF Optimized Rack System Selection Guide
DCF Optimized Rack System Selection Guide DCF Optimized Rack System: Optimized Design, Optimized Delivery, Optimized Value A Rack System Designed to Meet The Challenges Your Data Center Faces Today Your
More informationMazda CX7 2007-09 99-7508
INSTALLATION INSTRUCTIONS FOR PART 99-7508 APPLICATIONS Mazda CX7 2007-09 99-7508 KIT FEATURES DIN Radio Provision with Pocket ISO Mount Radio Provision with Pocket Double DIN Mount Radio Provision Stacked
More informationADC-APC Integrated Cisco Data Center Solutions
Advanced Infrastructure Solution for Cisco Data Center 3.0 Ordering Guide ADC-APC Integrated Cisco Data Center Solutions The evolution of data centers is happening before our eyes. This is due to the
More information2178-S Fiber Optic Splice Case
2178-S Fiber Optic Splice Case Instructions March 1998 34-7041-6288-1-B 1 2 Table of Contents 3M 2178-S Splice Case Description... 4 1.0 General...4 2.0 Specifications...4 3.0 Kit Contents...5 3M 2178-S
More informationDIGITUS Network & Server Cabinets. UNIQUE Series
DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door
More informationFIBER OPTIC CABLE PLANT DOCUMENTATION
C H A P T E R 13 FIBER OPTIC CABLE PLANT DOCUMENTATION JIM HAYES Documenting the fiber optic cable plant is a necessary part of the design and installation process for the fiber optic network. Documenting
More informationHeating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
More information19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.
19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile
More informationRack Systems Solutions
Rack Systems Solutions Designed to simplify cable management and improve power distribution Engineered by APC by Schneider Electric for Dell, NetShelter S is the next-generation rack enclosure solution
More informationDATA CENTRES POWERED BY EXCEL
DATA CENTRES POWERED BY EXCEL MAXIMISE EFFICIENCY BOOST PERFORMANCE INCREASE R.O.I. WITHOUT COMPROMISE Excel is a world-class premium performance end-to-end infrastructure solution. Designed, manufactured,
More informationConcepts. Products. Service. Lindner Plus Organisation
Concepts Products Service Lindner Plus Organisation Building new solutions. Lindner undertakes major worldwide projects in all areas of interior finishes, insulation technology, industrial services and
More informationTime needed: ~3h for lid replacement only. Add 1h for operation harness in lid and ~2h more for installing drive unit and cable harness in trunk.
DIY for replacing trunk lid and/or retrofitting electrical operation of trunk lid. This document is meant to be a support and give advice on the procedure but I will take no responsibility for any damage
More informationUsing a Fabric Extender with a Cisco Nexus 5000 Series Switch
CHAPTER Using a Fabric Extender with a Cisco Nexus 5000 Series Switch This chapter describes the Cisco Nexus 000 Series Fabric Extenders (FEXs) and includes these sections: Information About, page - Cisco
More informationDigital Link Cross Connect (DLx ) System User Manual
Issue, April 998 Digital Link Cross Connect (DLx ) System User Manual Content Page TRODUCTION... Revision History... Trademark Information... Admonishments... Compliance Statement... Certification... Standards...
More informationNorthpower Fibre UFB Services Agreement Service Description for Direct Fibre Access Service
Northpower Fibre UFB Services Agreement Service Description for Direct Fibre Access Service 1 Interpretation 1.1 The Direct Fibre Access Service described in this Service Description will be available
More informationData Centre Solutions
Issue 6 Data Centre Solutions RACKS POWER COOLING MONITORING SECURITY SERVICE & SUPPORT The simple route to the perfect data centre Data centres are complex systems. Software, hardware and IT infrastructure
More informationKnürr Smaract. Knürr Smaract. CompactRack
CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.
More informationONTRAC WIRE MESH CABLE TRAY SYSTEM
P R O D U C T D ATA S H E E T ONTRAC WIRE MESH CABLE TRAY SYSTEM K E Y F E AT U R E S Available in two styles: Shaped and Standard Tray Easy to use pathway solution that supports large quantities of network
More informationADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER
ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect Introduction The primary
More informationCNC Tool Storage Solutions
Solutions CNC TOOL STORAGE SOLUTIONS Thanks to the flexibility of the CNC line, your tools will be protected during regular handling, transportation and storage. The Rousseau CNC tool rack distinguishes
More informationASKING FOR ASSISTANCE
ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM - 5:00 PM Monday - Friday, Pacific Time Write To: Gefen LLC c/o Customer
More informationGENUINE PARTS INSTALLATION INSTRUCTIONS
GENUINE PARTS INSTALLATION INSTRUCTIONS DESCRIPTION: Illuminated Kick Plate APPLICATION: Rogue (2011) PART NUMBER: 999G6 GX010 KIT CONTENTS: Item A B C G H QTY 1 1 1 D 1 E 1 F 3 15 6 Description Kick Plate,
More informationInstaPATCH Cu Cabling Solutions for Data Centers
SYSTIMAX Solutions InstaPATCH Cu Cabling Solutions for Data Centers Design Guidelines August 2008 www.commscope.com Contents Overview 1 Instapatch Cu Solution Specification 2 Harness Assembly Design 3
More informationRACK ENCLOSURES & ACCESSORIES
RACK ENCLOSURES & ACCESSORIES RACK ENCLOSURES NetshelterTM 1 NetShelter VX / NetShelter VS 2 Open Frame Racks 3 NetShelter ES 4 NetShelter WX Part Number Model Height Width Depth Color Application Doors
More informationThe color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.
10 Cables The cables referred to below are provided with standard single- and multimode fibers. Other commercially available fibers can be provided on request. The bare fibers are colored in all cases
More information4 Small Cables Sealing Kit: Wrap Style
4 Small Cables Sealing Kit: Wrap Style I N S T A L L A T I O N I N S T R U C T I O N Gel Wrap Kit For Sealing up to 4 Small Cables in FOSC 450 & FOSC 600 Closures Max. Combined Diameter Closure Port of
More informationHow To Build A T7 Rack For Information Technology
THE NEXT GENERATION RACK FOR INFORMATION TECHNOLOGY THE RACK CABINET FOR INFORMATION TECHNOLOGY T7, THE HI-TECH HEART OF THE BLADESHELTER SYSTEM The real answer to the requirements of: Safety Versatility
More informationBelden. Optical Fiber Catalog. One Enterprise. One Infrastructure. One Partner. Belden IBDN FiberExpress Systems
Belden Optical Fiber Catalog One Enterprise. One Infrastructure. One Partner. Belden IBDN FiberExpress Systems With the IBDN FiberExpress Systems, Belden takes a complete approach to fiber optic cabling.
More informationTIER-1/TIER-2 FIBER CERTIFICATION KITS
MaxTester 940 Fiber Certifier OLTS TIER-1/TIER-2 FIBER CERTIFICATION KITS EXFO s Fiber Certification kits cover all test requirements to perform clear, fast and first-time-right system acceptance. This
More informationCoat Racks Floor Racks Hooks Hangers Hook Panels Wardrobes
Coat Racks Floor Racks Hooks Hangers Hook s Wardrobes Phone: 913-281-4555 Fax: 913-281-4554 Website: www.emcospi.com E-mail: info@emcospi.com Aluminum & Hardwood Coat Racks Whenever large groups gather
More informationBUILDING INSTRUCTIONS
etap2hw 38 mm I2C to LCD Interface BUILDING INSTRUCTIONS October 2013 P. Verbruggen Rev 1.01 15-Oct-13 Page 1 Table of Contents Chapter 1 General Information 1.1 ESD Precautions 1.2 Further Supplies 1.3
More informationDepending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.
ASSEMBLY 1 - EPS V2 POWER UNIT (SOLUTION 5) 1.1 - POSITIONING INSIDE THE SEAT TUBE WITH ELASTIC SUPPORT IN THE SEAT BRACKET TUBE Depending on which elastic support you have you can secure the V2 power
More information19" Open Rack for Network and Cabling Management
19" Open Rack for Network and Cabling Management Feartures: The CLM-221X-XXXX openrack is a solution of easier assemblying, more competitive price for our customers. All components can be seperated by
More informationDeveloping the Green Data Center
Products and Solutions to Support Energy Efficiency Ordering Guide Table of Contents Developing the Green Data Center Introduction...5 Airflow Management in the Data Center...6 Angled Panels Glide Cable
More informationSFP Transceiver Specifications
APPENDIXB This appendix provides cabling specifications for the SFP transceivers supported on the Cisco ME 60 Ethernet switch. Figure B-1 shows an optical SFP transceiver with the major features labeled.
More informationCascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009
Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide Version 8.2 March 2009 Trademarks Riverbed, the Riverbed logo, Riverbed Cascade, and Cascade are trademarks of Riverbed Technology,
More informationKnürr DCM. Knürr DCM. 19 Server Rack System 19 Heavy Duty Rack 1.2 to 1.9 1.1
Knürr DCM 19 Server Rack System 19 Heavy Duty Rack 1.2 to 1.9 1.1 Knürr DCM conquers the world Standardization in the data center begins with the Knürr DCM! The Knürr DCM is the modular building block
More informationNext Generation Frame System
Introduction Frames ADC KRONE S Next Generation Frame product line has fibre frames designed to fit a variety of termination, splice, and storage applications. Each frame option is designed with an emphasis
More informationHow To Make A Fibre Cable For A Data Centre
LANmark-OF Fibre Optic Solutions for Data Centres Complex Data Centres require fibre solutions CORE SWITCH ACCESS SWITCH SERVER SAN SWITCH LANmark-OF Slimflex Patch Cords LANmark-OF Single Mode LANmark-OF
More information