Dimensional drawing Setting options All types O,1(S) Connection type WLL 160-F122 WLL 160-F420 WLL 160-E122 WLL 160-E420 1 L+ brn

Similar documents
W 160: Miniature series for optimum solutions

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

W150: Miniature photoelectric switch series with completely integrated electronics

intelligent solutions

W 27-2: The photoelectric switch series with expanded possibilities

W 36: Mastering complex tasks reliably

W 260: Standard photoelectric switch series for a broad range of applications

W 18-3: Incorporated application Know-how, expanded functionality, high level of equipment availability

LUT Luminescence scanners: Seeing what no-one else can

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

W160T: With the smallest LED light spot

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

W 2: Subminiature photoelectric switch series: extremely small and extremely strong

BOS 73K... BOS 74K...

Electrical connection

fiber-optic sensors WLL180T, Fiber-optic photoelectric sensor

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

V180-2 M18 Cylindrical Photoelectric Sensor Series

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

For accurate positioning in warehouse and conveying areas

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Digital display DA 48

Color Mark Sensor with Red or Green LED E3S-VS

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

The new generation: WLL180T photoelectric sensor with fiber-optic cable. Around the corner at High Speed

photoelectric highlights

Universal Voltage Terminal Photoelectric E3JM

Cross-beam scanning system to detect slim objects. 100 mm in

Electronic Pressure Switch EDS 300

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Fiber-Optic Photoelectric Sensor

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Adjustment functions for both span and shift have been incorporated

mecotron Safety relay ESTOP-2 For emergency stop monitoring

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

Universal or individual application solutions. WLL190T-2. Sensor Configuration for Individual Applications

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Digital Pressure Measuring Instrument MDR480

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Instruction Manual Service Program ULTRA-PROG-IR

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Photoelectric sensors W100, Photoelectric proximity sensor, energetic

Overview. Application Areas. DMP Position Finder

Speed Control Relays SX2

D ATA S H E E T. DT50 Laser class 1. Laser distance sensor

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

MAIN CATALOGUE MAKING SENSE OF TECHNOLOGY

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Safety technique. Emergency stop module BO 5988 safemaster

ONLINE DATA SHEET. Contrast sensors KTM KTM-WP11181P

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

crm+25/d/tc/e Extract from our online catalogue: Current to:

Color sensors CS8, CS8-1

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

technical data (according to IEC )

CONFIGURABLE SAFETY RELAYS

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

HERZ-Thermal Actuators

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

How To Make An Ultrasonic Sensor

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

MINI MCR-SL-R-UI(-SP)

LCD Readout Digital Pressure Switch

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Safety Relays ESM/ESM-F

is then retained absolutely without interruption.

Operating instructions Optical distance sensor O1D100 O1D / / 2012

Photoelectric sensors V180-2, Photoelectric retro-reflective sensor, Standard optics

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Thermal-Magnetic Circuit Breaker M1-..

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Safety automation solutions

DALI RC BASIC SO. Control unit Operating instructions

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Electronic Pressure Switch EDS 3000

ACS-30-EU-EMDR-10-MOD

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Quick Connect. quick - simple - efficient.

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Smart Sensing Solutions Since 1954

Transcription:

WLL 0 Photoelectric Fiber-Optic Switch, Red Light -- DC Scanner Scanning range max. m Through-beam Scanning distance max. 0 mm Sensitivity setting with potentiometer, scaled Large selection of LL fiber-optic cables (accessories) Switch-off delay 0 to 00 ms Contamination control output and test input for equipment and testing Dimensional drawing... 0. ø.. Setting options All types SENS. IN.. TIER OFF L.ON ON D.ON O O,(S) 0 0 Plug pin, or connection cable Protective hood Locking the fiber-optic cables (press down) Releasing the fiber-optic cables (press lug) ounting bracket, supplied with equipment Indication of correct fiber-optic cable mounting Red LED signal strength indicator (lights when switching threshold is exceeded) Green LED signal strength indicator (lights when operating reserve is exceeded >.) Sensitivity scale Sensitivity switch ( turns) Light/dark switching Switch-off delay 0... 00 ms Time delay on/off switch C R s V Connection type WLL 0-F WLL 0-F0 WLL 0-E WLL 0-E0 Accessories Cable receptacles LL fiber-optic cables x0. mm pin, wht gra L+ Alarm TE wht L+ VA SENSICK

WLL 0 Specifications WLL 0- F F0 E E0 Suitable fiber-optic cables LL plastic fiber-optic cable series Scanning distances Dependent on used fiber-optic cable type Oper. range, through-beam 0... 00 mm(with tip adapter 0... m) Oper. scanning distance, scanner 0...0 mm ) Adjustable sensitivity Potentiometer, rotations w. scaling 0 Light source ), light type Light reception with operating reserve LED, visible red light ( Spot-Control ) Light reception without operating reserve LED, visible red-orange light ( Spot-Control ) Light spot diameter Dependent on the scanning range Opening angle of fiber-optic cables Approx. Supply voltage V S DC 0... 0 V ) Residual ripple ) ±0% Current consumption ) 0 ma outputs PNP, open collector: NPN, open collector: Output current I A max. 00 ma Light receiver, switching type Light/dark switching p. slide switch Response time ) / ax. switching frequ. ) 0. ms / 00/s VA contamination message 00 ma, static Test input TE ) Transmitter off; PNP: TE after +V Transmitter off; NPN: TE after 0 V Time delay T OFF (switch-off delay) Selectable, per slide switch Time range Adjust., 0... 00 ms; potentiometer 0 Connection type: connection cable PVC, m ) ; x 0. mm, ø. mm plug pin, VDE protection class 0) V Protection circuits ) A, B, C, D Enclosure rating IP Ambient temperature Operation... + C Storage 0... +0 C Weight With connection cable approx. 0 g With plug approx. 0 g Housing material Housing: ABS ) Scanned material with 0 % reflectance (with reference to standard white according to DIN 0) ) Average service life 00,000 h at T U = + C ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load ) Signal operating time with ohmic load ) With light/dark ratio : ) TE not with plug model ) Do not bend connection cable below 0 C 0) Rated voltage DC 0 V ) A = V S connections reversepolarity Type B = Inputs and outputs reversepolarity C = Interference pulse suppression D = Outputs overload and short-circuit Ordering information WLL 0-F WLL 0-E WLL 0-F0 WLL 0-E0 Order no. 00 00 00 0 00 SENSICK

WLL 0T Photoelectric Fiber-Optic Switch, Teach-In, Red Light -- DC Scanner Scanning range max. m Through-beam Scanning distance max. 0 mm Automatic setting of the switching threshold and hysteresis with Teach-In per push button or via external control wire Large selection of LL plastic fiber-optic cables (accessories) frequency 0/s or 0/s, switchable Dimensional drawing. 0.... ø.... Setting options All types L. ON D. ON NOR Hi 0 0 Plug pin, or connection cable Protective hood Lock the fiber-optic cables (press down) Release the fiber-optic cables (press lug) ounting bracket, supplied with equipment Indication of correct fiber-optic cable mounting LED signal strength indicator, red (lights when switching threshold is exceeded) LED signal strength indicator, green Selector switch light ( L.ON )/dark switching ( D.ON ) Selector switch response time, NOR (00 µs)/ HI (00 µs) Selector switch switch-off delay On ( OFF DLY )/off ( OFF ); 0 ms fix Operating mode selector switch // Push button Teach-In C R s V Connection type WLL 0T-F WLL 0T-E WLL 0T-F0 WLL 0T-E0 Accessories Cable receptacles LL fiber-optic cables x0. mm pin, ora L+ VA wht L+ SENSICK

WLL 0T Specifications WLL 0T- F F0 E E0 Suitable fiber-optic cables LL plastic fiber-optic cables Scanning distances Dependent on used fiber-optic cable type Oper. range, through-beam 0... 00 mm(with adapter tips 0... m) Oper. scanning distance, scanner 0... 0 mm ) Adjustable sensitivity Automatic, per key or mode ode selector switch position ax. range, set permanently position key activated position key inactive Equipment in sensor mode Per push button (only active if mode Switch is in position Extern Only active, if mode switch is in position PNP: control wire + V NPN: control wire 0 V Light source ), light type LED, visible red light Light spot diameter Dependent on the range Opening angle of fiber-optic cables Approx. Supply voltage V S DC 0... V Residual ripple ) V SS Current consumption ) 0 ma outputs PNP, open collector: NPN, open collector: Output current I A max. 00 ma Light receiver, switching type Light/dark switching per slide switch Response time ) /ax. switching freq. ) Dependent on selected operating mode! ode -Selector switch in Pos. or Selector switch Response time in NOR position: 0. ms /0/s, selectable Selector switch Resp. time in Pos. HI : 0. ms /0/s ) VA contamination message 0 ma, one shot, pulse length 0 ms Time delay T OFF (switch-off delay) 0 ms fixed, selectable, per slide switch Connection type: connection cable PVC, m ) ; x0.mm, ø.0 mm plug pin, VDE protection class ) V Protection circuits 0) A, B, C, D Enclosure rating IP Ambient temperature Operation... + C Weight Housing material ) Scanned material with 0% reflectance (with reference to standard white according to DIN 0) ) Average service life 00.000 h at T U = + C Storage 0... + 0 C With connection cable approx. 0 g With plug approx. 0 g Housing: ABS ) ay not exceed or fall short of V S tolerances ) Without load ) Signal operating period with ohmic load ) With light/dark ratio : ) Scanning distance reduction approx. 0 % ) Do not bend connection cable below 0 C ) Withstand voltage DC 0 V 0) A = V S connections reversepolarity B = Inputs and outputs reversepolarity C = Interference pulse suppression D = Outputs overload and short-circuit Ordering Information Type WLL 0T-F WLL 0T-F0 WLL 0T-E WLL 0T-E0 Order no. 00 0 00 00 00 SENSICK

WLL0T Photoelectric Fiber-Optic Switch, Teach-In. Precise sensitivity setting (per x push of button); WLL 0T steps Slide switch NOR or HI Detection Through-beam Detection Through-beam Parts present Parts present Push Taste button drücken LON D. ON NOR HI Push button en LON D. ON NOR HI ODE switch in pos. The button is pressed twice. This operating mode provides high sensitivity and is ideal for very precise switching points. The WLL 0T optimizes the switching threshold and hysteresis per µ-processor automatically and stores them in EEPRO. No special experience in precise alignment of optoelectronic components necessary. Activate signal s Through-beam ; even thin or transparent objects are detected. Detection ; strong background interference, small or dark scanning objects, simple marks with contrast differences. signal pause s; then activate signal > s Alarm impulse 0 ms? error, signal difference between part present/absent too small. Check application. after s.. Simple sensitivity setting (per x push of button); WLL 0T steps Slide switch NOR or HI Detection Through-beam Parts in light path Parts not in light path Push Taste button drücken ODE switch in pos. Activate signal s No alarm output function in mode after s. The button is only pressed once. This operating mode provides simple handling. The WLL0T detects existing background interference automatically. The WLL00T optimizes the switching threshold and stores it in EEPRO. No special experience in setting the sensitivity of optoelectronic components necessary. Through-beam ; even small or partially transparent parts, which do not interrupt the light path completely, are detected. Detection ; background interference considered. SENSICK

WLL 0T. ax. scanning range, fixed setting; WLL 0T Scanning range set permanently to Always 0 Hz* Steps NOR or HI (optionially 0 Hz or 0 Hz) Detection Through-beam Parts not in light path Parts in light path Slide switch to pos. * Press Taste button x drücken Not possible if selector switch is set to, scanning range internally fixed to. ODE switch in pos. Activate signal s No alarm output function in mode after s. anual: The imum scanning range is set permanently in the pos..with the ODE switch. *The switching is always 0 Hz, independent of the operating mode selector switch NOR/HI. Per : The button is only pressed once very simple handling. The maximum scanning range is set per. The WLL 0 T stores the basic signal in EEPRO and the switching threshold and hysterisis. No special experience in precise alignment of optoelectronic components necessary. Very simple handling. This operating mode is ideal for large differences in signals. Through-beam ; objects interrupt the light beam. Detection ; no or little background interference, objects with large differences in contrast.. oving objects; precise sensitivity adjustment (per x push of button); WLL 0T steps Slide switch NOR or HI Detection Through-beam Parts move through the light path Parts not in light path Press Taste button drücken > s Press button > s en ODE switch in Pos. for moving objects. The button is pressed twice. The simple handling makes precise sensitivity adjustment possible although objects are moving. The WLL0T optimizes per µ-processor the switching threshold and hysterisis and stores them in EEPRO. No special experience in precise alignment of optoelectronic components necessary. Activate signal s Objects can only be taught in during movement (rejection check; equipment cannot be stopped precisely). signal pause s; then activate signal > s Alarm impuls 0 ms? error, signal difference between part present/absent too small. Check application. after s. SENSICK

WLL 0T Photoelectric Fiber-Optic Switch, Teach-In Functions WLL 0T Response time/ switching NOR: 0 Hz; max. scanning distance. HI: 0 Hz, scanning distance 0 %. Select before! Switch-off delay TOFF For switching output. Optional connection, 0 ms fixed. To ensure that your control can also detect shorter events. Selector switch switching output L.ON: light switching D.ON: dark switching optionally in PNP or NPN. Connection technique Optionally plug, pin (no alarm output) or -wire connecting cable. Alarm output mode: signals error. (): signals insufficient signal reserve, e.g., due to soiling or misalignment (not with plug version pin). WLL0T Assembly technology Assembly and disassembly on tophat profile rail mounting by pulling the locking device. ounting technique Simple snap-on on tophat profile rails. ounting bracket supplied with equipment. µ-processor technique with EEPRO Permanent storage of taught-in switching threshold and hysteresis, even when there are longer interruptions of voltage. button Sensitivity setting at the push of a button. No special knowledge of phototelectric switches required. Only active if ODE selector switch is set to pos. (manipulation protection). LED display red, green mode: Signalization process. Permanently blinking: error. Permanently lit: o.k. Sensor operation: LED red: switching threshold exceeded LED green: received signal >. or < 0. External signal Signal active Exact sensibility adjustement t t t -- s -- s >s -- s PNP + V WLL 0 T NPN 0 V Indicator for correct fiber-optic cable mounting. Scanning range max. mode selector switch Separate from operating mode functions, and consequently simple and easy-to-understand handling; no double functions. : aximum scanning range set permanently. Caution: switching independent of operating mode selection; switching always 0 Hz. : WLL0T in TEACH- IN mode. Optimum switching point setting at the simple push of a button ( or times). : optionally : The taught-in switching threshold and hysteresis are stored in EEPRO. The WLL 0 T operates in sensor mode after s. External (): Optimum adjustment using external control signal. Ideal if the WLL0T is not accessible or part changes are often aligned automatically. Fiber-optic cable lock Press down bracket: fiber-optic cables are locked. Press the lug: fiber-optic cables are released. Fiber-optic cable attachment Transmitter fiber-optic cable Receiver fiber-optic cable Suitable fiber-optic cable: plastic fiber-optic cables of the LL series (see the description of the LL variants). BUZZER For acoustic support. Short tone after = O.K. Long tone after = error or application not suitable. SENSICK