W 160: Miniature series for optimum solutions

Size: px
Start display at page:

Download "W 160: Miniature series for optimum solutions"

Transcription

1 W 0 Photoelectric switches Photoelectric proximity switches, BGB Photoelectric proximity switches, energetic W 0: iniature series for optimum solutions Photoelectric reflex switches Through-beam photoelectric switches P/e switches w. fibre-optic cable (proximity mode) P/e switches w. fibre-optic cable (through-beam mode) SENSICK CATALOGUE PPrincipal system characteristics are simple handling, large scanning ranges and a reduced number of sensor types thanks to integrated L./D. switches. Integrated intelligence features such as pre-failure signalling output, test input (cable versions only) or external teach-in (WLL 0 T) increase system reliability under severe environmental conditions. All W 0 optic variants are available in housing versions with axial or 90 light emission. WLL 0 fibre-optic cable photoelectric switches with switching point adjustment (manual using potentiometers or automatic at the push of a button using the teach-in method) complete the W 0 series. LL plastic fibreoptic cables with approx. 0 different configuration options are available as accessories. W 0 switches have proven particularly successful in the following sectors: electronic component and printed circuit board production, the packaging and printing industries, assembly and handling systems, the construction of specialpurpose machines, and conveyor systems. The scanning ranges: WS/WE 0 through-beam photoelectric switch: m, slotted mask as accessory, WL 0 photoelectric reflex switch: m (PL 80 A), with polarising filter, WT 0 photoelectric proximity switch: energetic: scanning distance up to 00 mm (90 % remission), for standard scanning tasks; with focused optics: scanning distance between 8 and 0 mm, background blanking, small light spot, high sensitivity; with divergent optics (angle of dispersion approx. 0 ): scanning distance up to 80 mm; ideal for transparent objects.

2 W 0 m Resistor production: fibre-optic WLL 0 switches can detect even the thinnest of wires without any problem. b Checking the presence of caps and covers: Using a WT 0 photoelectric proximity switch to detect lids and WS/WE 0 through-beam photoelectric switches to monitor system timing. v The WT 0 miniature photoelectric proximity switch is used in film and foil processing to control feed tension. n Checking caps and labels using WT 0 photoelectric proximity switches. SENSICK CATALOGUE

3 WT 0 Photoelectric proximity switches, background blanking, red light -- DC...0 mm Photoelectric proximity switches Dimensional drawing WT Horizontal and vertical models Focused scanner with background blanking and great sensitivity Contamination control with green LED indicator and pre-failure signalling output Test input for equipment and system testing WT ø ø Adjustments possible All types L D Centre of optical axis, receiver Centre of optical axis, sender Plug -pin, 8 or connection cable Sensitivity adjustment Light/dark rotary switch: L = light-switching D = dark-switching Red LED signal strength indicator Green LED signal strength indicator C R s V Accessories page Cable receptacles 9 ounting brackets* 0 * included with delivery Connection types WT 0-P WT 0-P0 WT 0-N WT 0-N0 WT 0-P WT 0-P0 WT 0-N WT 0-N0 x0. mm -pin, 8 gra L+ VA TE L+ VA Operating diagram..0 Light reception >. Switching threshold () Red LED indicator without reserve Green LED indicator with reserve Switching output light-switching Switching output dark-switching Pre-failure signalling output (VA) SENSICK CATALOGUE

4 WT0 Technical data WT 0- P P0 N N0 P P0 N N0 Housing design Horizontal Vertical, max. typical... 0 mm ) Operating distance mm ) Background blanking From approx. 00 mm (background 90 % remission) ) Adjustable sensitivity Potentiometer, turns with scaling 0 Light source ), light type Light spot diameter Angle of dispersion, sender LED, red light Approx. mm at mm Focused, focus mm Supply voltage V S V DC ) Ripple ) ±0% Current consumption ) 0 ma Switching outputs PNP, open collector: NPN, open collector: Output current I A max. 00 ma Light receiver, switching type Light-/dark-switching via rotary switch Response time ) /max. switching freq. 8) 0.9 ms / 0/s Pre-failure signalling output (VA) 00 ma, static Test input TE 9) Sender off; PNP: TE to +V Sender off; NPN: TE to 0 V Connection types cable PVC, m 0) ; x 0. mm, l. mm plug VDE protection class ) Circuit protection ) -pin, 8 V A, B, C, D Enclosure rating IP Ambient temperature T A Operation C...+ C Storage 0 C...+0 C Weight with cable Approx. 0 g with plug Approx. 0 g Housing material Housing: ABS; optics: PC ) Scanned material with 90 % remission (based on standard white according to DIN 0) ) Average service life 00,000 h at T A = + C ) Background 90 % remission ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load 8) With light/dark ratio : 9) TE not with plug model 0) Do not bend below 0 C ) Reference voltage 0 V DC ) A = V S connections reverse-polarity B = Inputs and outputs reversepolarity C = Interference pulse suppression D = Outputs overload and shortcircuit 0 (mm) Operating distance, max. typical 00 0 Order information Type WT 0-P WT 0-P0 WT 0-N WT 0-N0 WT 0-P WT 0-P0 WT 0-N WT 0-N0 Part no Scanning range on white, 90 % remission Scanning range on gray, 8 % remission Scanning range on black, % remission Operating reserve (mm) Operating distance max. typical SENSICK CATALOGUE

5 WT 0 Photoelectric proximity switches, energetic, red light -- DC mm Photoelectric proximity switches Dimensional drawing WT Horizontal and vertical models Energetic scanner for standard applications Contamination control with green LED indicator and pre-failure signalling output Test input for device and system testing WT ø ø. Adjustments possible All types L D Centre of optical axis, receiver Centre of optical axis, sender Plug -pin, 8 or connection cable Sensitivity adjustment Light/dark rotary switch: L = light-switching D = dark-switching Red LED signal strength indicator Green LED signal strength indicator C R s V Accessories page Cable receptacles 9 ounting brackets* 0 * included with delivery Connection types WT 0-P WT 0-P0 WT 0-N WT 0-N0 WT 0-P8 WT 0-P80 WT 0-N8 WT 0-N80 x0. mm -pin, 8 gra L+ VA TE L+ VA Operating diagram..0 Light reception >. Switching threshold () Red LED indicator without reserve Green LED indicator with reserve Switching output light-switching Switching output dark-switching Pre-failure signalling output (VA) 8 SENSICK CATALOGUE

6 WT0 Technical data WT 0- P P0 N N0 P8 P80 N8 N80 Housing design Horizontal Vertical, max. typical mm ) Operating distance mm ) Adjustable sensitivity Potentiometer, turns with scaling 0 Light source ), light type LED, red light Light spot diameter Approx. mm at 00 mm Angle of dispersion, sender Approx..8 Supply voltage V S V DC ) Ripple ) ±0% Current consumption ) 0 ma Switching outputs PNP, open collector: NPN, open collector: Output current I A max. 00 ma Light receiver, switching type Light-/dark-switching via rotary switch Response time ) / ax. switching freq. ) 0.9 ms / 0/s Pre-failure signalling output (VA) 00 ma, static Test input TE 8) Sender off; PNP: TE to +V Sender off; NPN: TE to 0 V Connection types cable PVC, m 9) ; x 0. mm, l. mm plug VDE protection class 0) Circuit protection ) -pin, 8 V A, B, C, D Enclosure rating IP Ambient temperature T A Operation C...+ C Storage 0 C...+0 C Weight with cable Approx. 0 g with plug Approx. 0 g Housing material Housing: ABS; optics: PC ) Scanned material with 90 % remission (based on standard white according to DIN 0) ) Average service life 00,000 h at T A = + C ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : 8) TE not with plug model 9) Do not bend below 0 C 0) Reference voltage 0 V DC ) A = V S connections reverse-polarity B = Inputs and outputs reversepolarity C = Interference pulse suppression D = Outputs overload and shortcircuit (mm) Operating distance, max. typical Scanning range on white, 90 % remission Scanning range on gray, 8 % remission Scanning range on black, % remission 00 0 Operating reserve (mm) Operating distance max. typical Order information Type WT 0-P WT 0-P0 WT 0-N WT 0-N0 WT 0-P8 WT 0-P80 WT 0-N8 WT 0-N80 Part no SENSICK CATALOGUE 9

7 WT 0 Photoelectric proximity switches, divergent optics, infrared light -- DC mm Photoelectric proximity switches Dimensional drawing WT Horizontal and vertical models Scanner with large aperture angle for greater tolerances of target position Contamination control with green LED indicator and pre-failure signalling output Test input for device and system testing WT ø ø Adjustments possible All types L D Centre of optical axis, receiver Centre of optical axis, sender Plug -pin, 8 or connection cable Sensitivity adjustment Light/dark rotary switch: L = light-switching D = dark-switching Red LED signal strength indicator Green LED signal strength indicator C R s V Accessories page Cable receptacles 9 ounting brackets* 0 * included with delivery Connection type WT 0-P WT 0-P0 WT 0-N WT 0-N0 WT 0-P WT 0-P0 WT 0-N WT 0-N0 x0. mm -pin, 8 gra L+ VA TE L+ VA Operating diagram..0 Light reception >. Switching threshold () Red LED indicator without reserve Green LED indicator with reserve Switching output light-switching Switching output dark-switching Pre-failure signalling output (VA) 80 SENSICK CATALOGUE

8 WT 0 Technical data WT 0- P P0 N N0 P P0 N N0 Housing design Horizontal Vertical, max. typical mm )) Operating distance mm )) Adjustable sensitivity Potentiometer, turns with scaling 0 Light source ), light type LED, infrared light Light spot diameter Approx. 0 mm at 80 mm Angle of dispersion, sender Approx. 0 Supply voltage V S V DC ) Ripple ) ±0% Current consumption ) 0 ma Switching outputs PNP, open collector: NPN, open collector: Output current I A max. 00 ma Light receiver, switching type Light-/dark-switching via rotary switch Response time ) /max. switching freq. 8) 0.9 ms/0/s Pre-failure signalling output (VA) 00 ma, static Test input TE 9) Sender off; PNP: TE to +V Sender off; NPN: TE to 0 V Connection type cable PVC, m 0) ; x 0. mm, l. mm plug VDE protection class ) Circuit protection ) -pin, 8 V A, B, C, D Enclosure rating IP Ambient temperature T A Operation C...+ C Stockage 0 C...+0 C Weight with cable Approx. 0 g with plug Approx. 0 g Housing material Housing: ABS; optics: PCC ) Scanned material with 90 % remission (based on standard white according to DIN 0) ) Object size 0 x 0 mm ) Average service life 00,000 h at T A = + C ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load 8) With light/dark ratio : 9) TE not with plug model 0) Do not bend below 0 C ) Reference voltage 0 V DC ) A = V S connections reverse-polarity B = Inputs and outputs reversepolarity C = Interference pulse suppression D = Outputs overload and shortcircuit (mm) Operating distance Scanning range on gray, 8 % remission Scanning range on black, % remission, max. typical Scanning range on white, 90 % remission 00 0 Operating reserve (mm) Operating distance max. typical Order information Type WT 0-P WT 0-P0 WT 0-N WT 0-N0 WT 0-P WT 0-P0 WT 0-N WT 0-N0 Part no SENSICK CATALOGUE 8

9 WL 0 Photoelectric reflex switches, red light -- DC Scanning range m Photoelectric reflex switches Horizontal and vertical models Polarisation filter for detection of object with reflective surfaces Contamination control with green LED indicator and pre-failure signalling output Test input for device and system testing Dimensional drawing WL0... WL ø ø. Adjustments possible All types L D Centre of optical axis, receiver Centre of optical axis, sender Plug -pin, 8 or connection cable Sensitivity adjustment Light/dark rotary switch: L = light-switching D = dark-switching Red LED signal strength indicator Green LED signal strength indicator C R s V Accessories page Cable receptacles 9 ounting brackets* 0 Reflectors** 0 * included with delivery ** Reflector P 0 included with delivery Connection types WL 0-P WL 0-P0 WL 0-N WL 0-N0 WL 0-P WL 0-P0 WL 0-N WL 0-N0 x 0. mm -pin, 8 gra L+ VA TE L+ VA Operating diagram..0 Light reception >. Switching threshold () Red LED indicator without reserve Green LED indicator with reserve Switching output light-switching Switching output dark-switching Pre-failure signalling output (VA) 8 SENSICK CATALOGUE

10 WL 0 Technical data WL 0- P P0 N N0 P P0 N N0 Housing design Horizontal Vertical Scanning range, max. typical/on refl m/PL80A max. typical/on refl m/p0 (included) Operating range m/p0 Adjustable sensitivity Potentiometer, turns with scaling 0 Light source ), light type LED, red light with polarising filter Light spot diameter Approx. 0 mm at.0 m Angle of dispersion, sender Approx.. Supply voltage V S V DC ) Ripple ) ±0% Current consumption ) 0 ma Switching outputs PNP, open collector: NPN, open collector: Output current I A max. 00 ma Light receiver, switching type Light-/dark-switching via rotary switch Response time ) /max. switching freq. ) 0.9 ms / 0/s Pre-failure signalling output (VA) 00 ma, static Test input TE ) Sender off; PNP: TE to +V Sender off; NPN: TE to 0 V Connection types cable PVC, m 8) ; x 0. mm, l. mm plug VDE protection class 9) Circuit protection 0) -pin, 8 V A, B, C, D Enclosure rating IP Ambient temperature T A Operation C...+ C Storage 0 C...+0 C Weight with cable Approx. 0 g with plug Approx. 0 g Housing material Housing: ABS; optics: PA ) Average service life 00,000 h at T A = + C ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) TE not with plug model 8) Do not bend below 0 C 9) Reference voltage 0 V DC 0) A = V S connections reverse-polarity B = Inputs and outputs reversepolarity C = Interference pulse suppression D = Outputs overload and shortcircuit Scanning range and operating reserve Order information Type WL 0-P WL 0-P0 WL 0-N WL 0-N0 WL 0-P WL 0-P0 WL 0-N WL 0-N0 Part no (m) 0... Reflector type Operating range PL 80 A P 0 PL0 A /PL0 A PL0 A/PLA PL0 A Reflective tape Diamond Grade Operating range m m m m m m Scanning range, max. typical Operating reserve Operating range Scanning range max. typical (m) SENSICK CATALOGUE 8

11 WS/WE 0 Through-beam photoelectric switches, infrared light -- DC Scanning range 8. m Through-beam photoelectric switches Dimensional drawing WS/WE Horizontal and vertical models Slotted masks for increasing switching frequency Contamination control with green LED indicator and pre-failure signalling output Test input for device and system testing WS/WE ø ø. Adjustments possible All types Centre of optical axis sender/ receiver Plug -pin, 8 or connection cable Light/dark rotary switch: L = light-switching D = dark-switching Sensitivity adjustment Indicator, red (sender WS active) Green LED signal strength indicator (receiver WE) L D C R s V Connection types WS/WE0-P WS/WE0-N WS/WE0-P WS/WE0-N WS/WE0-P0 WS/WE0-N0 WS/WE0-P0 WS/WE0-N0 Operating diagram..0 Light reception >. Switching threshold () Red LED indicator without reserve Green LED indicator with reserve Switching output light-switching Accessories page Cable receptacles 9 ounting brackets* 0 Slotted mask * included with delivery Sender x0. mm L+ TE -pin, 8 L+ TE NC Switching output dark-switching Pre-failure signalling output (VA) x0. mm -pin, 8 Receiver L+ VA L+ VA 8 SENSICK CATALOGUE

12 WS/WE 0 Technical data WS/WE 0- P P0 N N0 P P0 N N0 Housing design Horizontal Vertical Scanning range, max. typical m Operating range 0...m Operating range with filter, 0...m width.0 m Adjustable sensitivity Potentiometer, turns with scaling 0 Light source ), light type LED, infrared light Light spot diameter Approx. 00 mm at m Angle of dispersion, sender Approx.. Angle of dispersion, receiver Approx. Supply voltage V S V DC ) Ripple ) ±0% Current consumption ) sender 0 ma receiver 0 ma Switching outputs PNP, open collector: NPN, open collector: Output current I A max. 00 ma Light receiver, switching type Light-/dark-switching via rotary switch Response time ) /max. switching freq. ). ms / 00/s Pre-failure signalling output (VA) 00 ma, static Test input TE ) Sender off: TE to 0 V Connection types cable PVC, m 8) sender WS x 0. mm, l. mm receiver WE x 0. mm, l. mm plug VDE protection class 9) Circuit protection 0) sender WS receiver WS -pin, 8 V A, B A, B, C, D Enclosure rating IP Ambient temperature T A Operation C...+ C Storage 0 C...+0 C Weight with cable Sender/receiver each approx. 0 g with plug Sender/receiver each approx. 0 g Housing material Housing: ABS; optics: PC ) Average service life 00,000 h at T A = + C ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) TE not with plug model 8) Do not bend below 0 C 9) Reference voltage 0 V DC 0) A = V S connections reverse-polarity B = Inputs and outputs reversepolarity C = Interference pulse suppression D = Outputs overload and short-circuit ) Part no. includes transmitter and receiver Scanning range and operating reserve (m) 8 Operating range Without slotted mask With slotted mask mm, BL-0-0 Scanning range, max. typical 00 0 Order information Type Part no. ) WS/WE0-P 009 WS/WE0-P0 009 WS/WE0-N WS/WE0-N0 009 WS/WE0-P 009 WS/WE0-P WS/WE0-N WS/WE0-N0 009 Operating reserve (m) Operating range Scanning range, max. typical 0 SENSICK CATALOGUE 8

13 WLL 0 Photoelectric fibre-optic switches, red light -- DC Through-beam systems Proximity systems Scanning range max. m max. 0 mm Sensitivity adjustment with potentiometer, scaled Large selection of LL fibre-optic cables (accessories) Off-delay ms Pre-failure signalling output and test input for device and system testing Dimensional drawing ø.. 8 Adjustments possible All types SENS. IN. AX. TIER L. O D. O,(S) Plug -pin, 8 or connection cable Protective hood Fibre-optic cable lock (press down) Fibre-optic cable release (press lug) ounting bracket, supplied with equipment Indication of correct fibre-optic cable mounting Red LED signal strength indicator (lights when switching threshold is exceeded) Green LED signal strength indicator (lights when operating reserve is exceeded >.) Sensitivity scale Sensitivity switch ( turns) Light-/dark-switching -delay ms Time delay on/off switch C R s V Accessories page Cable receptacles 9 ounting brackets* 0 LL fibre-optic cables 8 * included with delivery Connection types WLL 0-F WLL 0-F0 WLL 0-E WLL 0-E0 x0.8 mm -pin, 8 gra L+ Alarm TE L+ VA Operating diagram..0 -delay Light reception. Switching threshold () Red LED indicator (from switching threshold) Green LED indicator (from switching threshold with reserve) Transmitter-LED orange (reception without reserve) Transmitter-LED red (from switching threshold with reserve) Switching output (light-switching) Switching output (dark-switching) Pre-failure signalling output (VA) 8 SENSICK CATALOGUE

14 WLL 0 Technical data WLL 0- F F0 E E0 Suitable fibre-optic cables LL plastic fibre-optic cable series (p. 8) Scanning ranges Depend. on fibre-optic cable type used Scanning range, through-beam system mm(with tip adapter 0... m), scanner system 0...0mm ) Adjustable sensitivity Potentiometer, turns with scaling 0 Light source ), light type Light reception with operating reserve LED, visible red light ( spot control ) Light reception without operating reserve LED, visible red-orange light ( spot control ) Light spot diameter Dependent on scanning range Opening angle of fibre-optic cables Approx. Supply voltage V S V DC ) Ripple ) ±0% Current consumption ) 0 ma Switching outputs PNP, open collector: NPN, open collector: Output current I A max. 00 ma Light receiver, switching type Light-/dark-switching via slide switch Response time ) /max. switching freq. ) 0. ms / 00/s Pre-failure signalling output (VA) 00 ma, static Test input TE 8) Sender off; PNP: TE to +V Sender off; NPN: TE to 0 V Time delay T (-delay) Selectable, per slide switch Time range Adjust., ms; potentiometer 0 Connection types cable PVC, m 9) ; x 0. mm, l. mm plug VDE protection class 0) Circuit protection ) -pin, 8 V A, B, C, D Enclosure rating IP Ambient temperature T A Operation C...+ C Storage 0 C...+0 C Weight with cable Approx. 80 g with plug Approx. 0 g Housing material ABS ) Scanned material with 90 % remission (based on standard white according to DIN 0) ) Average service life 00,000 h at T A = + C ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : 8) TE not with plug model 9) Do not bend below 0 C 0) Reference voltage 0 V DC ) A = V S connections reversepolarity B = Inputs and outputs reversepolarity C = Interference pulse suppression D = Outputs overload and short-circuit Order information Type WLL0-F WLL0-E WLL0-F0 WLL0-E0 Part no SENSICK CATALOGUE 8

15 WLL 0T Photoelectric fibre-optic switches, teach-in, red light -- DC Through-beam systems Proximity systems Scanning range max. m max. 0 mm Automatic setting of the switching threshold and hysteresis with teach-in via button or external control cable ET Large selection of LL plastic fibre-optic cables (accessories) Switching frequency 80/s or 0/s, switchable Dimensional drawing ø Adjustments possible All types L. D. NOR Hi AX DLY Plug -pin, 8 or connection cable Protective hood Fibre-optic cable lock (press down) Fibre-optic cable release (press lug) ounting bracket, supplied with equipment Indication of correct fibre-optic cable mounting LED signal strength indicator, red (lights when switching threshold is exceeded) LED signal strength indicator, green Selector switch light- ( L. )/dark-switching ( D. ) Selector switch response time, NOR (00 µs)/ HI (00 µs) Selector switch -delay On ( DLY )/off ( ); 0 ms fix Operating mode selector switch AX/SET/RUN Teach-in button C R s V Connection types WLL0T-F WLL0T-E WLL0T-F0 WLL0T-E0 Operating diagram Light reception >. Switching threshold () Light reception < 0.9 Accessories page Cable receptacles 9 ounting brackets* 0 LL fibre-optic cables 8 * included with delivery x0.8 mm -pin, 8 ora pnk L+ VA ET L+ ET 0 ms Switching output Red LED indicator Pre-failure signalling output (VA) Green LED indicator 88 SENSICK CATALOGUE

16 WLL 0T Technical data WLL 0T- F F0 E E0 Suitable fibre-optic cables LL plastic fibre-optic cable series (p. 8) Scanning ranges Depend. on fibre-optic cable type used Scanning range, through-beam system mm(with tip adapter 0... m), scanner system 0...0mm ) Adjustable sensitivity Automatic, via TEACH-IN key or AX mode ode selector switch AX position ax. range, set permanently SET position TEACH-IN key activated RUN position TEACH-IN key inactive, equipment in sensor mode TEACH-IN manual Via button (only active if mode switch is in SET position external TEACH-IN Only active, if mode switch is in RUN position PNP: control wire + V NPN: control wire 0 V Light source ), light type LED, visible red light Light spot diameter Dependent on range Opening angle of fibre-optic cables Approx. Supply voltage V S 0... V DC Ripple ) V SS Current consumption ) 0 ma Switching outputs PNP, open collector: NPN, open collector: Output current I A max. 00 ma Light receiver, switching type Light-/dark-switching via slide switch Response time ) /max. switching freq. ) 0. ms /80/s, selectable Dependent on selected operating mode: ode -selector switch in pos. AX or selector switch Response time in NOR position Selector response time in pos. HI 0. ms /0/s ) Pre-failure signalling output (VA) 0 ma, one shot, pulse length 0 ms Time delay T (switch-off delay) 0 ms fixed, selectable, per slide switch Connection types cable PVC, m 8) ; x 0.8 mm, l.0 mm plug VDE protection class 9) Circuit protection 0) -pin, 8 V A, B, C, D Enclosure rating IP Ambient temperature T A Operation C...+ C Storage 0 C...+0 C Weight with cable Approx. 80 g with plug Approx. 0 g Housing material Housing: ABS ) Scanned material with 90 % remission (based on standard white according to DIN 0) ) Average service life h at T A = + C ) ay not exceed or fall short of V S tolerances ) Without load ) Signal transit period with resistive load ) With light/dark ratio : ) reduction approx. 0 % 8) Do not bend below 0 C 9) Reference voltage 0 V DC 0) A = V S connections reverse-polarity B = Inputs and outputs reversepolarity C = Interference pulse suppression D = Outputs overload and short-circuit Order information Type WLL0T-F WLL0T-F0 WLL0T-E WLL0T-E0 Part no SENSICK CATALOGUE 89

17 WLL0T Photoelectric fibre-optic switches, teach-in. Precise sensitivity setting (via x push of button); WLL 0T TEACH-IN steps Switching speed Slide switch NOR or HI Detection system Through-beam Detection system Through-beam system system Positioning of the parts START STOP TEACH IN Parts present Parts not present Sensor mode TEACH-IN manual Reset: RUN SET AX DLY L D. NOR HI Push Taste button drücken AX DLY L D. NOR HI Beep Push button en AX DLY L D. NOR HI Beep SET RUN AX DLY L D. NOR HI TEACH-IN external ET via control signal ODE switch in RUN pos. Activate ET signal s ET signal pause s, then activate ET signal > s Automatically in sensor operation after s The TEACH-IN button is pressed twice. This operating mode provides high sensitivity and is ideal for very precise switching points. The WLL 0T optimizes the switching threshold and hysteresis via µ-processor automatically and stores them in EEPRO. No special experience in precise alignment of optoelectronic components necessary. Applications: Through-beam system; even thin or transparent objects are detected. Detection system; strong background interference, small or dark scanning objects, simple marks with contrast differences. Alarm impulse 0 ms? TEACH-IN error, signal difference between part present/absent too small. Check application.. Simple sensitivity setting (via x push of button); WLL 0T TEACH-IN steps Switching speed Slide switch NOR or HI Detection system Through-beam system Positioning of the parts START STOP TEACH IN Parts in light path Parts not in light path Sensore mode TEACH-IN manual Reset: RUN SET AX DLY L D. NOR HI Push Taste button drücken AX DLY L D. NOR HI Beep SET RUN AX DLY L D. NOR HI TEACH-IN external ET via control signal ODE switch in RUN pos. Activate ET signal s No alarm output function in TEACH-IN mode Automatically in sensor operation after s. The TEACH-IN button is only pressed once. This operating mode provides simple handling. The WLL0T system detects existing background interference automatically. It optimizes the switching threshold and stores it in EEPRO. No special experience in setting the sensitivity of opto-electronic components necessary. Applications: Through-beam system; even small or partially transparent parts, which do not completely interrupt the light path, are detected. Detection system; background interference considered. 90 SENSICK CATALOGUE

18 WLL 0T. ax. scanning range, fixed setting; WLL 0T Scanning range set permanently to AX Switching Always 80 Hz* speed TEACH-IN Steps NOR or HI (optionially 80 Hz or 0 Hz) Detection system Through-beam system Positioning of the parts START STOP START STOP TEACH IN Parts not in light path Parts in light path Sensor mode TEACH-IN manual Slide switch to AX pos. RUN AX* AX DLY L D. NOR HI Reset: RUN SET AX DLY L D. NOR HI Press Taste button x drücken AX DLY L D. NOR HI Beep SET RUN AX DLY L D. NOR HI TEACH-IN external ET via control signal Not possible if selector switch is set to AX, scanning range internally fixed to AX. ODE switch in RUN pos. Activate ET signal s No alarm output function in TEACH-IN mode Automatically in sensor operation after s. anual: The AXimum scanning range is set permanently in the AX pos.with the ODE switch. *The switching speed is always 80 Hz, independent of the operating mode selector switch NOR/HI. Via TEACH-IN: The TEACH-IN button is only pressed once very simple handling. The maximum scanning range is set via TEACH-IN. The WLL 0 T stores the basic signal in EEPRO and the switching threshold and hysterisis sensor operation. No special experience in precise alignment of optoelectronic components necessary. Applications: Very simple handling. This operating mode is ideal for large differences in signals. Through-beam system; objects interrupt the light beam. Detection system; no or little background interference, objects with large differences in contrast.. oving objects; precise sensitivity adjustment (via x push of button); WLL 0T TEACH-IN steps Switching speed Slide switch NOR or HI Detection system Through-beam Parts move through the light path system Positioning of the parts START STOP TEACH IN Parts not in light path Sensor mode TEACH-IN manual Reset: RUN SET AX DLY L D. NOR HI Press Taste button drücken > s AX DLY L D. NOR HI Beep Press button > s en AX DLY L D. NOR HI Beep SET RUN AX DLY L D. NOR HI TEACH-IN external ET via control signal ODE switch in Pos. RUN TEACH-IN for moving objects. The TEACH-IN button is pressed twice. The simple TEACH-IN handling makes precise sensitivity adjustment possible although objects are moving. The WLL0T optimizes the switching threshold and hysteresis via µ-processor and stores them in EEPRO. No special experience in precise alignment of optoelectronic components necessary. Activate ET signal s Applications: Objects can only be taught in during movement (rejection check; equipment cannot be stopped precisely). ET signal pause s; then activate ET signal > s Alarm impuls 0 ms? TEACH-IN error, signal difference between part present/absent too small. Check application. Automatically in sensor operation after s. SENSICK CATALOGUE 9

19 WLL 0T Photoelectric fibre-optic switches, teach-in WLL 0T TEACH-IN functions Response time/ switching speed NOR: 80 Hz; max. system scanning distance. HI: 0 Hz, system scanning distance 0 %. Select before TEACH-IN! Off-delay T For switching output. Optional connection, 0 ms fixed. To ensure that your control can also detect shorter events. Selector switch switching output L.: light-switching D.: dark-switching optionally in PNP or NPN. Connection technique Optionally 8 plug, -pin (no alarm output) or -wire connecting cable. Alarm output TEACH-IN mode: signals TEACH-IN error. Sensor mode (RUN): signals insufficient signal reserve, e.g., due to contamination or misalignment (not with plug version 8 -pin). WLL 0T Assembly technology Assembly and disassembly on top hat profile rail mounting by pulling the locking device. ounting technique Simple snap-on on top hat profile rails. ounting bracket supplied with equipment. µ-processor technique with EEPRO Permanent storage of taught-in switching threshold and hysteresis, even when there are longer interruptions of voltage. TEACH-IN button Sensitivity setting at the push of a button. No special knowledge of phototelectric switches required. Only active if ODE selector switch is set to SET pos. (manipulation protection). LED display red, green TEACH-IN mode: Signalization TEACH-IN process. Permanently blinking: TEACH-IN error. Permanently lit: TEACH-IN o.k. Sensor operation: LED red: switching threshold exceeded LED green: received signal >. or < 0.9 External TEACH-IN signal ET Signal active Exact sensibility adjustement t t t -- s -- s > s -- s PNP + V WLL 0 T ET NPN 0 V Indicator for correct fibre-optic cable mounting. Scanning range max. ET TEACH-IN mode selector switch Separate from operating mode functions, and consequently simple and comprehensible handling; no dual functions. AX: aximum scanning range set permanently. Caution: switching speed independent of operating mode selection; switching speed always 80 Hz. SET: WLL0T in manual TEACH- IN mode. Optimum switching point setting at the simple push of a button ( or times). RUN: optionally TEACH-IN manual: The taught-in switching threshold and hysteresis are stored in EEPRO. The WLL 0T operates in sensor mode after s. External TEACH-IN (ET): Optimum system adjustment using external control signal. Ideal if the WLL 0T is not accessible or part changes are often aligned automatically. Fibre-optic cable lock Press down bracket: fibre-optic cables are locked. Press the lug: fibre-optic cables are released. Fibre-optic cable attachment n Transmitter fibre-optic cable m Receiver fibre-optic cable Suitable fibre-optic cable: plastic fibre-optic cables of the LL series (see the description of the LL variants). BUZZER For acoustic support. Short tone after TEACH-IN = O.K. Long tone after TEACH-IN = error or application not suitable. 9 SENSICK CATALOGUE

20 WLL 0T SENSICK CATALOGUE 9

W150: Miniature photoelectric switch series with completely integrated electronics

W150: Miniature photoelectric switch series with completely integrated electronics Product group W50 Photoelectric proximity switch BGS Photoelectric proximity switch energ. Photoelectric reflex switch W50: iniature photoelectric switch series with completely integrated electronics Through-beam

More information

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems WLL 0(T) Photoelectric switches Photoelectric switches with fibre-optic cable Proximity mode Photoelectric switches with fibre-optic cable Through-beam mode Photoelectric switches WLL 0(T), fibre-optic

More information

W 27-2: The photoelectric switch series with expanded possibilities

W 27-2: The photoelectric switch series with expanded possibilities W - Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W -: The photoelectric switch series with expanded possibilities metres

More information

W 260: Standard photoelectric switch series for a broad range of applications

W 260: Standard photoelectric switch series for a broad range of applications W 0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic Photoelectric reflex switches W 0: Standard photoelectric switch series for a broad range of

More information

W 36: Mastering complex tasks reliably

W 36: Mastering complex tasks reliably Lichtschranken W Photoelectric Baureihe switches WL - Photoelectric proximity switches, BGS Photoelectric reflex switches W : astering complex tasks reliably Through-beam photoelectric switches for temperatures

More information

intelligent solutions

intelligent solutions Lichtschranken W 8- Photoelectric Baureihe switches WL - Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 8-: Integrated stateof-the-art technology

More information

W 18-3: Incorporated application Know-how, expanded functionality, high level of equipment availability

W 18-3: Incorporated application Know-how, expanded functionality, high level of equipment availability Photoelectric proximity switches, FGS Photoelectric reflex switches Through-beam photoelectric switches W -: Incorporated application Know-how, expanded functionality, high level of equipment availability

More information

W 2: Subminiature photoelectric switch series: extremely small and extremely strong

W 2: Subminiature photoelectric switch series: extremely small and extremely strong Photoelectric proximity switches BGS Photoelectric proximity switches energetic, (V optics) Photoelectric reflex switches Through-beam photoelectric switches W : Subminiature photoelectric switch series:

More information

LUT Luminescence scanners: Seeing what no-one else can

LUT Luminescence scanners: Seeing what no-one else can LUT Luminescence scanners Luminescence scanners LUT Luminescence scanners: Seeing what no-one else can Special features: A semi-conductor light source is used in the LUT series no lamp change required.

More information

W160T: With the smallest LED light spot

W160T: With the smallest LED light spot W0T: With the smallest LED light spot BGS Photoelectric proximity switches Photoelectric proximity switches mark sensor Photoelectric proximity switches energetic Photoelectric reflex switches SSystem

More information

V180-2 M18 Cylindrical Photoelectric Sensor Series

V180-2 M18 Cylindrical Photoelectric Sensor Series D ata S h e e t V80-8 Cylindrical Photoelectric Sensor Series A rounded concept, not only economically. Cylindrical photoelectric switches offer the benefits of very fast commissioning and compact design.

More information

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output

More information

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor Miniature Sensors - S1 The universal miniature photoelectric sensor Two threaded front mounting holes Two slotted rear mounting holes Anti-tampering sensor (no adjustment) Standard optic functions and

More information

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up

More information

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049

More information

BOS 73K... BOS 74K...

BOS 73K... BOS 74K... BFB/BOS When there s no space for a photoelectric sensor, there is only one solution: user fiber optics! If there are no particular demands for toughness an ambient temperature or chemical resistance,

More information

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular

More information

fiber-optic sensors WLL180T, Fiber-optic photoelectric sensor

fiber-optic sensors WLL180T, Fiber-optic photoelectric sensor ONLINE DATA SHEET www.mysick.com fiber-optic sensors WLL180T, Fiber-optic photoelectric sensor WLL180T-P434 fiber-optic sensors WLL180T, Fiber-optic photoelectric sensor Model Name > WLL180T-P434 Part

More information

Photoelectric sensors W100, Photoelectric proximity sensor, energetic

Photoelectric sensors W100, Photoelectric proximity sensor, energetic ONLINE DATA SHEET www.mysick.com Photoelectric sensors W100, Photoelectric proximity sensor, energetic WT100-P4439 Photoelectric sensors W100, Photoelectric proximity sensor, energetic Model Name > WT100-P4439

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

photoelectric highlights www.automation.datalogic.com

photoelectric highlights www.automation.datalogic.com photoelectric miniature sensors S8 series The new S8 series of compact sensors offers excellent detection performances, usually associated with sensors that have larger dimensions and a higher price. The

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!

More information

Photoelectric sensors V180-2, Photoelectric retro-reflective sensor, Standard optics

Photoelectric sensors V180-2, Photoelectric retro-reflective sensor, Standard optics ONLINE DATA SHEET www.mysick.com Photoelectric sensors V180-2, Photoelectric retro-reflective sensor, Standard optics VL180-2P42436 Photoelectric sensors V180-2, Photoelectric retro-reflective sensor,

More information

Color Mark Sensor with Red or Green LED E3S-VS

Color Mark Sensor with Red or Green LED E3S-VS Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical

More information

Electrical connection

Electrical connection (I)GSU 14B Ultrasonic Label Fork Dimensioned drawing Part No. 501 09234 4mm 12-30 V DC 4 m/s Ultrasonic forked sensor for universal application Large mouth width, hence also suitable for booklets or fan-fold

More information

For accurate positioning in warehouse and conveying areas

For accurate positioning in warehouse and conveying areas TECHNICAL DESCRIPTION DMP Position finder For accurate positioning in warehouse and conveying areas AUDIN - 8, avenue de la malle - 170 Saint Brice Courcelles - Tel : 0..0.0.1 - Fax : 0..0.8.0 - Web :

More information

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm Series 7069A Fiber Optics The 7069A coupled with the appropriate cable forms a fiber optic sensor controller system capable of detecting objects as small as 0.01mm dia. and color marks on backgrounds of

More information

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector. Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval series Light Curtain Sensors New type with radial cross ray method Small objects and flat tape-like objects detected Convenient simplified wiring requiring no clock (synchronization) line Compact and flat

More information

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M. Inductive sensor, IE series, IE08, DC-wire, Standard series, Flush Inductive sensor Sensing range.5 mm Short-circuit protection (pulsed) Dimensional drawing 8x Robust brass housing, nickelplated with fine

More information

technical data (according to IEC 60947-5-2)

technical data (according to IEC 60947-5-2) Photoelectric sensors: Series 3#30 & 3#31 ü Complete miniature sensor series mm in rugged Crastin housings ü Shock & vibration resistant due to fully vacuum-potted electronics ü Diffuse sensors with precise

More information

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option REGISTRATION MARK SENSORS MARK EYE PRO 2 Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option Registration Mark Photoelectric Sensors 2-115 High-Resolution Registration

More information

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004 Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical

More information

The new generation: WLL180T photoelectric sensor with fiber-optic cable. Around the corner at High Speed

The new generation: WLL180T photoelectric sensor with fiber-optic cable. Around the corner at High Speed P r o d u C t i n f o r m at i o n The new generation: WLL180T photoelectric sensor with fiber-optic cable Around the corner at High Speed WLL180T: World-class performance and scanning range SICK has been

More information

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit

More information

Universal Voltage Terminal Photoelectric E3JM

Universal Voltage Terminal Photoelectric E3JM Universal Voltage Terminal Photoelectric Universal AC/DC Photoelectric Sensor with Built-in Timer Easy-to-wire terminal block Built-in timer offers selectable ON-delay, OFF-delay and one-shot Relay or

More information

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED) NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

Speed Control Relays SX2

Speed Control Relays SX2 SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................

More information

MAIN CATALOGUE MAKING SENSE OF TECHNOLOGY

MAIN CATALOGUE MAKING SENSE OF TECHNOLOGY MAIN CATALOGUE MAKING SENSE OF TECHNOLOGY MAKING SENSE OF TECHNOLOGY TABLE OF CONTENTS Corporate Profile Remote Photoelectric Systems Self-Contained Photoelectric Systems Self-Contained Light Curtain Systems

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS Photoelectric These sensors use light sensitive elements to detect objects and are made up of an emitter (light source) and a receiver. Four types of photoelectric

More information

Overview. Application Areas. DMP Position Finder

Overview. Application Areas. DMP Position Finder T E C N I C A D E S C R I P T I O N DMP Position Finder AUDIN - 8, avenue de la malle - 5170 Saint Brice Courcelles - Tel : 0.6.04.0.1 - Fax : 0.6.04.8.0 - Web : http: www.audin.fr - Email : info@audin.fr

More information

ONLINE DATA SHEET WT34-R220 W34 PRODUCT PORTFOLIO

ONLINE DATA SHEET WT34-R220 W34 PRODUCT PORTFOLIO ONLINE DATA SHEET WT34-R220 W34 A B C D E F WT34-R220 W34 Illustration may differ Ordering information Type Part no. WT34-R220 1019233 Other models and accessories www.sick.de/w34 H I J K L M N O P Q R

More information

Instruction Manual Service Program ULTRA-PROG-IR

Instruction Manual Service Program ULTRA-PROG-IR Instruction Manual Service Program ULTRA-PROG-IR Parameterizing Software for Ultrasonic Sensors with Infrared Interface Contents 1 Installation of the Software ULTRA-PROG-IR... 4 1.1 System Requirements...

More information

Digital display DA 48

Digital display DA 48 Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital

More information

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity Photoelectric Sensor with Built-in Amplifier Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity H Photo-IC provides long sensing distance: 15 m for through-beam, 4 m for retroreflective,

More information

Fiber-Optic Photoelectric Sensor

Fiber-Optic Photoelectric Sensor Fiber-Optic Photoelectric Sensor High Performance Amplifier Has Fast Response Time, Longer Sensing Distance and Self-Diagnostic Functions Ultra fast 20 µsec. response time (-F) Extended sensing distance

More information

mecotron Safety relay ESTOP-2 For emergency stop monitoring

mecotron Safety relay ESTOP-2 For emergency stop monitoring E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated

More information

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Contents 1 Preliminary note 3 1.1 Symbols used 3 1.2 Warning signs used 3 2 Safety instructions

More information

ONLINE DATA SHEET. www.mysick.com. Contrast sensors KTM KTM-WP11181P

ONLINE DATA SHEET. www.mysick.com. Contrast sensors KTM KTM-WP11181P ONLINE DATA SHEET www.mysick.com Contrast sensors KTM KTM-WP11181P Contrast sensors KTM Model Name > KTM-WP11181P Part No. > 1062199 At a glance Established mini housing High grayscale resolution Increased

More information

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Control Devices Catalogue. Control Devices. Preferred and Standard Products Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface

More information

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes SI-COLO Series SI-COLO2-LWL-HAMP-COL4 - Big measuring range: typ. 25 mm... 40 mm (with optical fiber and attachment optics KL-14 or KL-17) - Large assortment of optical fibers available (reflected or transmitted

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Electronic Pressure Switch EDS 300

Electronic Pressure Switch EDS 300 Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output

More information

Color sensors CS8, CS8-1

Color sensors CS8, CS8-1 ONLINE DATA SHEET www.mysick.com Color sensors CS8, CS8-1 CS81-P1112 Color sensors CS8, CS8-1 Model Name > CS81-P1112 Part No. > 1028224 At a glance One (CS8-1) or four (CS8-4) colors can be saved 12.5

More information

Universal or individual application solutions. WLL190T-2. Sensor Configuration for Individual Applications

Universal or individual application solutions. WLL190T-2. Sensor Configuration for Individual Applications MANUAL Universal or individual application solutions. Fast and reliable programming menu driven and at the push of a button: sensor properties and parameters are individually determined directly on the

More information

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6 L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Smart Sensing Solutions Since 1954

Smart Sensing Solutions Since 1954 Smart Sensing Solutions Since 1954 X-tremely High Speed Photoelectric Registration Sensor 800-237-0946 ttco.com 813-886-4000 Photoelectric Registration Sensor The SMARTEYE X-MARK TM is the fastest, most

More information

MINI MCR-SL-R-UI(-SP)

MINI MCR-SL-R-UI(-SP) Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional

More information

Combi B Alarm box. Mounting instructions

Combi B Alarm box. Mounting instructions Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

crm+25/d/tc/e Extract from our online catalogue: Current to: 2015-10-26

crm+25/d/tc/e Extract from our online catalogue: Current to: 2015-10-26 Extract from our online catalogue: crm+25/d/tc/e Current to: 2015-10-26 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E info@microsonic.de

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

New XUY roller sensors

New XUY roller sensors Do you want to simplify the sensor integration in your conveyor systems? New XUY roller sensors for packet, boxes, letters on roller conveyors. Telemecanique Sensor s OsiSense TM XUY photoelectric sensors

More information

Operating instructions Switching amplifier for fibre optics. OBF5xx 704876 / 00 08 / 2010

Operating instructions Switching amplifier for fibre optics. OBF5xx 704876 / 00 08 / 2010 Operating instructions Switching amplifier for fibre optics OBF5xx 70876 / 00 08 / 00 Contents Preliminary note. Symbols used Functions and features. Applications Installation. Attaching the fibre optics

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

D ATA S H E E T. DT50 Laser class 1. Laser distance sensor

D ATA S H E E T. DT50 Laser class 1. Laser distance sensor D ATA S H E E T DT50 Laser class 1 Laser distance sensor DT50 Distance sensor Laser class 1 State-of-the-art time of flight technology for fast and accurate measurement results (range up to 10 m) Quick

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics

More information

FIRERAY 2000 Installation Guide

FIRERAY 2000 Installation Guide FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description

More information

How To Make An Ultrasonic Sensor

How To Make An Ultrasonic Sensor crm+ ultrasonic sensors Microsonic : TR Electronic: Tel: +49 231 975151-0 USA: 248-244-2280 Fax: +49 231 975151-51 Canada: 519-452-1233 www.microsonic.de www.trelectronic.com info@microsonic.de Description

More information

Digital Pressure Measuring Instrument MDR480

Digital Pressure Measuring Instrument MDR480 Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

Electronic Pressure Switch EDS 3000

Electronic Pressure Switch EDS 3000 For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or

More information

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete

More information

Givare NC-SRS 280 och 880

Givare NC-SRS 280 och 880 Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer) Operating Manual for the Electronic Built-in Interval Timer Micro II (Countdown Timer) Note: This document has been designed for our OEM customers. They can use it as supporting material when creating

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs 857 Micro Sensor General terms and conditions... P.1 Related Information Glossary of terms / General precautions... P.1019 / P.1027 Sensor selection guide... P.11~ / P.833~ About laser beam... P.1025 ~

More information

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529) Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall

More information

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G Auto-Levelling Rotary Laser Level RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G 77-496 / 77-429 / 77-439 / 77-497 / 77-427/ 77-441 Please read these instructions before operating the product Auto-Levelling

More information