Lecture 3 Power System Measurement. Course map

Similar documents
Using Current Transformers with the 78M661x

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

BSNL TTA Question Paper-Instruments and Measurement Specialization 2007

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Capacitor Voltage Transformer. Answers for energy.

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

Measurement of Power in single and 3-Phase Circuits. by : N.K.Bhati

Table of Contents. TransformerIQ FAQs 1

AVR127: Understanding ADC Parameters. Introduction. Features. Atmel 8-bit and 32-bit Microcontrollers APPLICATION NOTE

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB

Hideo Okawara s Mixed Signal Lecture Series. DSP-Based Testing Fundamentals 46 Per-pin Signal Generator

CURRENT TRANSFORMERS FOR ELECTRONIC WATTHOUR METERS ADVANCED MATERIALS THE KEY TO PROGRESS

Current & Instrument Transformers

EMI and t Layout Fundamentals for Switched-Mode Circuits

T Substation Maintenance and Commissioning Test Equipment

INTRODUCTION TO SYSTEM PROTECTION. Hands-On Relay School 2012

LEVERAGING FPGA AND CPLD DIGITAL LOGIC TO IMPLEMENT ANALOG TO DIGITAL CONVERTERS

Digital to Analog Converter. Raghu Tumati

Lab 14: 3-phase alternator.

Application/Connection Examples

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

SAMPLE OF THE STUDY MATERIAL PART OF CHAPTER 3. Symmetrical Components & Faults Calculations

Inductors in AC Circuits

Tire pressure monitoring

Section 3. Sensor to ADC Design Example

FREQUENCY RESPONSE ANALYZERS

Instrument Transformers Application Guide

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

Low and High Voltage Power Supplies

Considerations When Specifying a DC Power Supply

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

b 1 is the most significant bit (MSB) The MSB is the bit that has the most (largest) influence on the analog output

Medium-voltage transformers

Chapter 6: From Digital-to-Analog and Back Again

CT Analyzer: Coming to the Rescue. Introduction. Equivalent Circuit. Construction. Classification of a CT. Tony Porrelli, OMICRON, UK

DISTRIBUTION TRANSFORMER OVERLOAD PROTECTION TRIPPING CIRCUIT

CT Application Guide for the 489 Generator Management Relay

Power Meter Series 700

Tamura Closed Loop Hall Effect Current Sensors

Application Note. So You Need to Measure Some Inductors?

1. Oscilloscope is basically a graph-displaying device-it draws a graph of an electrical signal.

Medium voltage product. Instrument transformers for indoor applications Product overview

Understanding SMD Power Inductors. Application Note. July 2011

DIGITAL-TO-ANALOGUE AND ANALOGUE-TO-DIGITAL CONVERSION

DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION

Measuring Impedance and Frequency Response of Guitar Pickups

Specifying a Variable Frequency Drive s

Thyristor-controlled power supplies and battery chargers

Conversion Between Analog and Digital Signals

Solar Energy Conversion using MIAC. by Tharowat Mohamed Ali, May 2011

Transformers. Special transformers Reactors products

(3 )Three Phase Alternating Voltage and Current

Occupational Profile: Electrical & Electronics Engineering Technician

Current Transformers. Bonneville Power Administration. Steve Laslo For the Hands On Relay School (3-12) Revision 1.1. February 21,

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

AN-641 APPLICATION NOTE

SYNCHRONOUS MACHINES

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

Chapter 16. Current Transformer Design. Copyright 2004 by Marcel Dekker, Inc. All Rights Reserved.

Current Transformers

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

Module Title: Electrotechnology for Mech L7

Digital to Analog and Analog to Digital Conversion

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

Energy Management Energy Meter Type EM23 DIN

Step Response of RC Circuits

Kit Watt Audio Amplifier

User s Manual. Multifunction Transducer MT440

Simple Methods for Calculating Short Circuit Current Without a Computer By Dennis McKeown, PE GE Senior System Application Engineer

Lecture 24. Inductance and Switching Power Supplies (how your solar charger voltage converter works)

Sigma- Delta Modulator Simulation and Analysis using MatLab

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Properties of electrical signals

UDG1000 Hach PCX2200 Serial Port Input Driver configuration

INSTRUMENTATION AND CONTROL TUTORIAL 3 SIGNAL PROCESSORS AND RECEIVERS

Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Custom Products. Magnetic Components. Vishay Dale.

How To Choose A Transformer

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

13 ELECTRIC MOTORS Basic Relations

Module 11: Conducted Emissions

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD

Equipment: Power Supply, DAI, Transformer (8341), Variable resistance (8311), Variable inductance (8321), Variable capacitance (8331)

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Microcontroller to Sensor Interfacing Techniques

Earth Fault Detection Basics in Theory

HYDRUS ULTRASONIC METER

Iron Powder Cores for Switchmode Power Supply Inductors. by: Jim Cox

Voltech DC1000. Precision DC Bias Current Source

AN3306 Application note

Analog signals are those which are naturally occurring. Any analog signal can be converted to a digital signal.

Everything you need for protection scheme testing

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

Circulating Current Relay. Type IRXm

Transcription:

Lecture 3 Power System Measurement 1 Course map 2 1

Outline of the Lecture Instrument Transformers (NPAG Ch. 6) Voltage Transformer Current Transformers Measurement Setups Transducers (NPAG Ch. 22) 3 The Current Transformer (CT) Bushing type Medium Voltage High Voltage Medium Voltage 4 2

CT General Types Wound primary Traditional transformer with secondary and primary windings Bar primary The primary winding is a single bar, that passes through a core with the secondary winding. 5 CT Principle of Operation Traditional Electromagnetic transformer Is = Ip*Np/Ns Normally Bar type CTs are used 6 3

CT Equivalent Model 7 CTs Accuracy 8 4

Voltage Transformers (VT) Up to 5,5 meters Medium Voltage < 36kV High Voltage 9 VT General Types Electromagnetic type Commonly referred to as VT Traditional Electromagnetic transformer Used up to approx 130kV Thereafter insulation problems arise Capacitor Type Commonly referred to as CVT Series coupled capacitors Used up to EHV/UHV levels 10 5

VT Principle of Operation Traditional Electromagnetic transformer Vs = Vp*Ns/Np Connected either Phase Earth Phase Phase Single-pole Star coupled 11 Equivalent Model 12 6

CVT Principle of Operation Basic potential divider Inductive compensation to cancel effect of capacitive source impedance To reduce the size of capacitors, a VT is added on output side. 13 VT Design Factors Electromagnetic VT Flux density in core well below saturation Output design ranges 200-300 VA Insulation larger volume than windings Capacitive VTs More space conserving May include a VT Can be used for overloading High-Frequency signals on Power Line. 14 7

VT Connection VTs are single pole above 36 kv CVTs Phase to Earth VTs Phase to Phase, Phase to Earth Star coupling 15 VT - Accuracy Accuracy classes for measurement & revenue metering Accuracy classes for protection 16 8

Summary - VTs/CTs VTs and CTs are the primary measurement method for medium and high voltage Important design characteristics are Accuracy for revenue metering Linearity for protection Size = cost The output is further transformed using transducers. 17 Contents of the Lecture Instrument Transformers (NPAG Ch. 6) Voltage Transformer Current Transformers Measurement Setups Transducers (NPAG Ch. 22) 18 9

What do we need to measure? Voltage V Current I Frequency f Phase angle φ Power Q,P Position on/off.. 19 Current Measurement Connected to secondary side of CT Cannot sense direction Measurement types Mean sensing r.m.s. measurement 20 10

Voltage Measurement Connected to secondary of VT/CVT 21 Phase Angle Measurement Implemented using zero-crossing detection Sensitive to harmonics Connected to phases and quantities (U or I) as needed for measurement 22 11

Frequency Measurement Important for system operation Analog Digital conversion Fourier Transform for f analysis Accuracy up to 0,01% available, +/- 5 mhz Connected to VT or CT secondary 23 Power Measurement Measurement of P & Q Many configurations available Direction of the flow important 24 12

Outline of the Lecture Instrument Transformers (NPAG Ch. 6) Voltage Transformer Current Transformers Measurement Setups. Transducers (NPAG Ch. 22) 25 Wiring & Communication 26 13

Transducers A transducer is a device, usually electrical, electronic, or electro-mechanical, that converts one type of energy to another for various purposes including measurement or information transfer. In a broader sense, a transducer is sometimes defined as any device that converts a signal from one form to another. www.wikipedia.org 27 Benefits of using transducers Reduces the burden on instrument transformers Ability to mount display equipment remote from the measurement point Ability to use multiple display units per measurement point Reducing need for long wiring from instrument transformers 28 14

Transducer types Analog or Digital transducers Digital transducers (A/D conversion) Benefits Improved long-term stability More accurate r.m.s measurement Improved Communications Programmable scaling Reduced size Wider range of functions Output normally a RS-485 or 232 interface 29 Equivalent Model (analog) Output from a transducer normally a current source E.g. 4-20 ma as a function of input 30 15

A/D conversion Accuracy determined by Bit resolution, Least Significant Bit Non-linearity due to imperfections. Sampling & Aliasing 31 Sampling & Aliasing 32 16

A/D - Quantization Base circuit is the comparator If Input > Vref output = V+ If Input < Vref = Output = V- 33 Flash ADC Simple concept Fast Losses increase Several comparators needed Low resultion 34 17

Further AD-Converter types Integrator Integrating signal applied to input of comparator and reference Sigma Delta Oversampling of the input, and successive stages of comapration and summing. Accuracy still determined by Bit resolution, Least Significant Bit Non-linearity due to imperfections. Sampling & Aliasing 35 Questions or comments? 36 18