Basics of Electricity



Similar documents
SYNCHRONOUS MACHINES

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

Motor Fundamentals. DC Motor

DIRECT CURRENT GENERATORS

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Lab 14: 3-phase alternator.

Keywords: synchronous generator, synchronous motor, automatic voltage regulator, V- curves, synchronizing power, hunting, excitation system

Synchronous motor. Type. Non-excited motors

Science and Reactor Fundamentals Electrical CNSC Technical Training Group. Table of Contents

13 ELECTRIC MOTORS Basic Relations

Induction Motor Theory

Unit 33 Three-Phase Motors

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

AC Generators and Motors

8 Speed control of Induction Machines

How To Understand And Understand The Electrical Power System

Principles of Adjustable Frequency Drives

AC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

CHAPTER 5 SYNCHRONOUS GENERATOR

Synchronous generators are built in large units, their rating ranging from tens to hundreds of megawatts.

PART I THEORY, CONSTRUCTION, AND OPERATION

Physical Address: City: State: Zip Code:

AC Induction Motor Slip What It Is And How To Minimize It

INTRODUCTION TO SYNCHRONIZING AUTOMATIC SYNCHRONIZING CONSIDERATIONS AND APPLICATIONS

Power Plant Electrical Distribution Systems

ELECTRODYNAMICS 05 AUGUST 2014

*ADVANCED ELECTRIC GENERATOR & CONTROL FOR HIGH SPEED MICRO/MINI TURBINE BASED POWER SYSTEMS

Equipment: Power Supply, DAI, Universal motor (8254), Electrodynamometer (8960), timing belt.

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP

CONTINUOUS AUTOMATED FLUX MONITORING FOR TURBINE GENERATOR ROTOR CONDITION ASSESSMENT

The DC Motor/Generator Commutation Mystery. Commutation and Brushes. DC Machine Basics

Chapter 22: Electric motors and electromagnetic induction

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

Effective: September 10, 2006 Vermont Attachment 1 to Rule Public Service Board Page 1 of 6

How To Understand And Understand The Theory Of Electricity

FREQUENCY CONTROLLED AC MOTOR DRIVE

Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

SHIP SERVICE GENERATORS (AC)

Introduction. Three-phase induction motors are the most common and frequently encountered machines in industry

Inductance. Motors. Generators

Chen. Vibration Motor. Application note

Introduction. Upon completion of Basics of AC Motors you should be able to:

Appendix N: GENERATOR DATA SHEET FOR SYNCHRONOUS GENERATORS CONNECTED TO PG&E ELECTRIC SYSTEM

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Principles and Working of DC and AC machines

Prof. Krishna Vasudevan, Prof. G. Sridhara Rao, Prof. P. Sasidhara Rao

AC Generators. Basic Generator

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

1/29/2013. School. Generation Track. Overview Lecture. Generator Design, Connections, and Grounding

Motors and Generators

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

Understanding the Alternator

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

How the efficiency of induction motor is measured?

NATIONAL CERTIFICATE (VOCATIONAL)

Lab 8: DC generators: shunt, series, and compounded.

1. The diagram below represents magnetic lines of force within a region of space.

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

Direct Current Motors

Single-Phase AC Synchronous Generator

Theory of Heating by Induction

Three phase circuits

Edmund Li. Where is defined as the mutual inductance between and and has the SI units of Henries (H).

STUDY GUIDE: ELECTRICITY AND MAGNETISM

VOLTAGE REGULATOR AND PARALLEL OPERATION

Outline. Turbine Generators. Generator History 3/25/2014

Large Generators and High Power Drives

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR

PM734F - Technical Data Sheet Winding 28

ET 332b Ac Electric Machines and Power Systems

Simple Analysis for Brushless DC Motors Case Study: Razor Scooter Wheel Motor

UCI274C - Technical Data Sheet

IV. Three-Phase Induction Machines. Induction Machines

PHASE CONVERSION TECHNOLOGY OVERVIEW

PS-6.2 Explain the factors that determine potential and kinetic energy and the transformation of one to the other.

Preview of Period 16: Motors and Generators

UCI274H - Technical Data Sheet

Line Reactors and AC Drives

UNIT 3 AUTOMOBILE ELECTRICAL SYSTEMS

HIGH SPEED PERMANENT MAGNET SYNCHRONOUS MOTOR / GENERATOR DESIGN FOR FLYWHEEL APPLICATIONS

MEASURING INSTRUMENTS. By: Nafees Ahmed, Asstt, Prof, EE Deptt, DIT, Dehradun

Power measurement in balanced 3 phase circuits and power factor improvement. 1 Power in Single Phase Circuits. Experiment no 1

Application Note. So You Need to Measure Some Inductors?

Induced voltages and Inductance Faraday s Law

BCI184E - Technical Data Sheet

Chapter 24. Three-Phase Voltage Generation

operating under normal conditions supplying - isolated loads - an infinite bus - a fin1 te bus load.

Chapter 6. Synchronous Machines

Calculation of Temperature in a Large Turbine Generator with Multilayer Roebel Transposition Coils

Chapter 12: Three Phase Circuits

Drive circuit basics + V. τ e. Industrial Circuits Application Note. Winding resistance and inductance

Transcription:

Basics of Electricity Generator Theory PJM State & Member Training Dept. PJM 2014 8/6/2013

Objectives The student will be able to: Describe the process of electromagnetic induction Identify the major components of an AC generator Apply the formula for rotational speed Describe generator governor control Discuss the characteristics that affect or limit generator performance Describe MVAR and MW flow Describe the synchronization process of a generator PJM 2014 8/6/2013

Basic Operating Principles Electromagnetic Induction is the principle used by a generator to convert mechanical energy into electrical energy For this to happen, three things are needed: A magnetic field A current-carrying conductor A relative motion between the two This is the fundamental operating principle of generators, motors, transformers, inductors, and solenoids

Basic Operating Principles Generators use energy from the prime mover to turn the generator s rotor (moving portion) inside the generator s stator (static portion) Steam in a fossil or nuclear unit Water flow in a hydroelectric unit Fuel flow in a combustion turbine unit Wind flow in a wind generator A DC current flows through the field windings of the rotor creating a magnetic field As the rotor spins, it acts via electromagnetic induction to induce a voltage in the armature windings of the stator

Basic Operating Principles Output voltage of the generator is controlled by changing the strength of the magnetic field of the rotor. This is accomplished by controlling the amount of direct current (DC) or excitation current that is supplied to the rotor s field winding The excitation current is supplied by the exciter The stator s output to the system is a three-phase alternating current (AC) since the direction of the magnetic field changes in relation to the windings as the rotor turns 360 degrees One rotation is equal to a complete cycle of power

Basic Operating Principles Bismark Phasor Sim

Basic Operating Principles

A.C. Generator Components: Rotor Rotating Magnetic Field Series of Conductors

A.C. Generator Components: Rotor The basic function of the rotor is to produce a magnetic field of the size and shape necessary to induce the desired output voltage in the stator The rotating field is required to produce a given number of lines of magnetic flux which is obtained by: Ampere-turns Ampere-turns is the product of the number of turns in the rotor winding and the current that flows in the winding

A.C. Generator Components: Rotor Generator rotors are made of solid steel forgings with slots cut along the length for the copper windings Insulated winding bars are wedged into the slots and connected at each end of the rotor and are arranged to act as one continuous wire to develop the magnetic field

A.C. Generator Components: Rotor Two types of rotors: Salient-pole Used in low or moderate speed machines with separate field coils Speeds from 100 to 1,200 rpm Primarily for hydroelectric facilities Cylindrical Used in high-speed machines that utilize a slotted integral forging Speeds 1,200 rpm and above Primarily used for steam and combustion turbine facilities

A.C. Generator Components: Rotor Rotor design constraints include: Temperature: Ampere-turn requirements for the field increase with an increase in rating, which entails a combined increase in heating in the coil Mechanical force: Ampere-turn requirements for the field increase with an increase in rating causing a higher centrifugal load Electrical insulation: In older units, slot insulation is a primary thermal barrier, and as current increases, becomes a greater obstacle

A.C. Generator Components: Rotor Advantage: Air gap between the stator and rotor can be adjusted so that the magnetic flux can be sinusoidal including the waveform Disadvantage: Because of its weak structure it is not suitable for highspeed generation It is also expensive to fabricate Requires damper windings to prevent rotor oscillations during operations Due to low speed, they are constructed with a higher number of poles to achieve system frequency

A.C. Generator Components: Rotor Advantage: Cheaper than a salient-pole Its symmetrical shape, is better for highspeed application Losses in the windings are reduced Noise produced is less Disadvantage: Air gap is uniform Generated voltage is polygonal giving way to the susceptibility of harmonics

A.C. Generator Components: Rotor

A.C. Generator Components: Stator

A.C. Generator Components: Stator The stator is the stationary part of the generator that is comprised of a series of stationary windings or poles (phases) Basic function of the stator core is to provide a return path for the lines of magnetic flux, and support the coils of the stator winding The stator core is made of soft iron to provide the magnetic field path with a high permeability The iron is laminated to reduce eddy currents (opposing field) and hysteresis (power losses)

A.C. Generator Components: Stator Two-Pole Generators: In a two-pole generator, there are three armature winding coils installed in the stator North and south poles of the rotor are 1800 apart Four-Pole Generators: In a four-pole generator, there are six armature winding coils installed in the stator North and south poles of the rotor are 900 apart A generator which is connected to the grid has a constant speed dictated by grid frequency Bismark AC Generator Sim

A.C. Generator Components: Exciter

A.C. Generator Components: Exciter The function of the excitation system is to provide direct current for the generator rotor/field windings through slip rings to produce the magnetic field Maintains generator voltage, controls MVAR flow, and assists in maintaining power system stability During load changes or disturbances on the system, the exciter must respond, sometimes rapidly, to maintain the proper voltage at the generator terminals

Generator Rotational Speed Frequency is dependent on: Number of field poles Speed of the generator f = (N)(P)/120, where f = frequency (Hz) N = rotor speed (rpm) P = total number of poles 120 = Conversion from minutes to seconds and from poles to pole pairs (60 seconds/1 minute) x (2 poles/pole pair)

Generator Rotational Speed Example: 2 Poles 60 Hz = (3600 RPM)(2 Poles)/120

Generator Rotational Speed Example: 4 Poles 60 Hz = (1800 RPM)(4 Poles)/120

Generator Governor Control Governors control generator shaft speed Adjust generation for small changes in load Operate by adjusting the input to the prime mover Steam flow for fossil Water flow for hydro Fuel flow for combustion turbine Amount of governor control varies according to plant design Equivalent to a car s cruise control

Generator Governor Control The Watt centrifugal governor was the mechanical means for governor control Used weights that moved radially as rotational speed increased that pneumatically operated a servo-motor Electrohydraulic governing has replaced the mechanical governor because of: High response speed Low deadband Accuracy in speed and load control

Generator Governor Control

Generator Governor Control Load Rate of frequency decline from points A to C is slowed by load rejection Generators Generator governor action halts the decline in frequency and causes the knee of the excursion, and brings the frequency back to point B from point C It is important to note that frequency will not recover from point B to 60 Hz until the deficient control area replaces the amount of lost generation

Generator Governor Control: Droop Adding a droop characteristic to a governor forces generators to respond to frequency disturbances in proportion to their size Droop settings enable many generators to operate in parallel while all are on governor control and not compete with one another for load changes

Generator Governor Control: Droop

Generator Governor Control: Droop

Generator Governor Control: Deadband Deadband An additional feature displayed by governors The amount of frequency change a governor must see before it starts to respond Really a natural feature of the earliest governors caused by friction and gear lash (looseness or slop in the gear mechanism) Serves a useful purpose by preventing governors from continuously hunting as frequency varies ever so slightly

Generator Characteristics Generator limitation factors Power capability of the prime mover Heating of generator components (I2R losses) Necessity to maintain a strong enough magnetic field to transfer power from the rotor to the generator output

Generator Characteristics Heating of generator components Heat generated within the armature and field windings is directly related to the magnitude of current flowing through them Generator losses: Based on resistance of the field winding of the rotor Based on resistance and inductive reactance of the armature windings of the stator causing a voltage drop that subtracts from the output voltage Heat dissipated by the generator is limited by the cooling system design

Generator Characteristics Magnetic field strength Controlled by excitation voltage If excitation voltage is lowered: Voltage induced in A.C. windings is lowered More VARS absorbed by generator from system Undervoltage can cause overcurrent conditions in the stator and lead to armature or stator heating Capability curves provide Max/Min limits

Capability Curve

Nameplate Data Main Generator Nameplate Characteristic Data Rated Output 496,000 kva Rated Voltage 22,000 v Rated Stator Current 13,017 amps Rated Field Current 3,017 amps Power Factor 0.9 Poles 2 Phases 3 Electrical Connection Wye Rated Speed 3,600 RPM Rated Frequency 60 Hz Rated Hydrogen Pressure 48 psig Rated Hydrogen Purity 97%

Generator Capability Curve The steady-state capability of a generator as it is influenced by the power factor is divided into three major components on the curve Region A-B: Zero power factor lagging to rated power factor Generator is over-excited Field current is at rated value Capability limitation is field overheating Region B-C: Rated power factor lagging through unity to 0.95 power factor leading Capability limitation is dependent on the stator current Maximum nameplate stator amperes should not be exceeded

Generator Capability Curve Region C-D: leading power factor operation Excessive heating in the stator end-iron due to flux leakage from the core Capability limitation is end-iron heating This is also an underexcitation region and capability is further reduced by the voltage squared during reduced terminal voltage operation

Generator MW Flow & Power Angle Power Angle P

Generator MW Flow & Power Angle Rotor Angle On a transmission system is similar to rotor angle Load or Torque angle No Load Field pole of rotor is in phase with stator armature windings δ = 0 Load Added Rotor advances with respect to the stator MW s flow out of the machine Bismark Torque angle Sim

Generator Synchronization Synchronization is the process of precisely coordinating or matching two or more activities, devices, or processes in time Synchronization, in the electric industry, is the process of matching the speed, frequency, and voltage of a generator or other source to a running network Conditions must be met to prevent unwanted and excessive energy flows when paralleling

Generator Synchronization The objective of synchronization is to match speed and phase position so there is little or no transfer of energy when paralleling a unit to a system or two systems Voltage Magnitude (MVAR) Frequency Magnitude (MW) Phase Angle Deviation (MW) Phase Sequence (Current)

Generator Synchronization Manual synchronizing is performed by plant or field operators by manually adjusting frequency and voltage of the generator or area to be paralleled and ultimately closing the circuit breaker to tie the incoming system to the running system For manual synchronization, meter panels are used to provide information Individual bus and generator frequency meters Individual bus and generator AC voltmeters Synchroscope Two indicating lamps

Generator Synchronization Synchroscope is a multiple parameter information source Indicates a frequency difference between the generator or area and the running system (slip rate) Indicates if the generator or area frequency is running slower or faster than the running area Indicating incandescent lamps demonstrate that the incoming and running system are in phase Bismark Synch Lab

Generator Synchronizing Voltage Frequency Phase Angle

Summary Defined electromagnetic induction and how mechanical energy is converted into electrical energy Explained the major components of an AC Generator Applied the formula for generator rotational speed Described generator governor control to include the droop and deadband characteristics Described generator characteristics that can limit the performance of a generator Described MVAR and MW flow Described the process of synchronizing a generator to the system

Questions? PJM 2014 8/6/2013

Resources and References Rustebakke, Homer M. (1983). Electric Utility Systems and Practices. New York: John Wiley and Sons Miller, Robert H., & Malinowski, James H. (1993). Power System Operation. New York: McGraw-Hill Inc. PJM 2014 8/6/2013

Disclaimer: PJM has made all efforts possible to accurately document all information in this presentation. The information seen here does not supersede the PJM Operating Agreement or the PJM Tariff both of which can be found by accessing: http://www.pjm.com/documents/agreements/pjmagreements.aspx For additional detailed information on any of the topics discussed, please refer to the appropriate PJM manual which can be found by accessing: http://www.pjm.com/documents/manuals.aspx PJM 2014 8/6/2013