BCI184E - Technical Data Sheet
|
|
|
- Annis Barnett
- 9 years ago
- Views:
Transcription
1 BCI184E - Technical Data Sheet
2 BCI184E SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN and the relevant section of other international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C , AS1359. Other standards and certifications can be considered on request. TERMINALS & TERMINAL BOX Standard generators are 3-phase reconnectable with 12 ends brought out to the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access. VOLTAGE REGULATORS SX460 AVR - STANDARD With this self excited control system the main stator supplies power via the Automatic Voltage Regulator (AVR) to the exciter stator. The high efficiency semiconductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three phase full wave bridge rectifier. This rectifier is protected by a surge suppressor against surges caused, for example, by short circuit. SA465 AVR The SA465 shares all the features of the SX460, but additionally will support a range of electronic accessories, such as a droop Current Transformer (CT) to permit parallel operation with other ac generators. Voltage regulation is improved by use of this AVR. SX421 AVR When the SX421 AVR is supplied for use with a BC generator, it will be supplied loose for fitting in the setbuilder s control panel. This AVR also operates in a self-excited system. It combines all the features of the SA465 with, additionally, three-phase rms sensing for improved regulation and performance. Over voltage protection is provided via a separate circuit breaker. An engine relief load acceptance feature is built in as standard. SHAFT & KEYS All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. INSULATION/IMPREGNATION The insulation system is class 'H'. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. QUALITY ASSURANCE Generators are manufactured using production procedures having a quality assurance level to BS EN ISO The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN :2001. At no time will the steady-state voltage regulation exceed 2%. WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th ) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion. NB Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing typical of product range. 2
3 BCI184E WINDING 311 CONTROL SYSTEM A.V.R. VOLTAGE REGULATION SUSTAINED SHORT CIRCUIT INSULATION SYSTEM PROTECTION RATED POWER FACTOR STATOR WINDING WINDING PITCH WINDING LEADS STATOR WDG. RESISTANCE ROTOR WDG. RESISTANCE EXCITER STATOR RESISTANCE EXCITER ROTOR RESISTANCE R.F.I. SUPPRESSION WAVEFORM DISTORTION MAXIMUM OVERSPEED BEARING DRIVE END BEARING NON-DRIVE END WEIGHT COMP. GENERATOR WEIGHT WOUND STATOR WEIGHT WOUND ROTOR WR² INERTIA SHIPPING WEIGHTS in a crate SELF EXCITED STANDARD SX460 OPTIONAL SA465 SX421 (SUPPLIED LOOSE) ± 1.5 % ± 1.0 % ± 0.5 % SELF EXCITED MACHINES DO NOT SUSTAIN A SHORT CIRCUIT CURRENT CLASS H IP DOUBLE LAYER CONCENTRIC TWO THIRDS Ohms PER PHASE AT 22 C SERIES STAR CONNECTED 0.64 Ohms at 22 C 20 Ohms at 22 C Ohms PER PHASE AT 22 C BS EN & BS EN ,VDE 0875G, VDE 0875N. refer to factory for others NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% 2250 Rev/Min BALL RS. (ISO) BALL RS. (ISO) 1 BEARING 2 BEARING 128 kg 131 kg 43.6 kg 43.6 kg kg kg kgm kgm kg 141 kg PACKING CRATE SIZE TELEPHONE INTERFERENCE 84 x 59 x 75 (cm) 50 THF<2% 84 x 59 x 75 (cm) 60 TIF<50 COOLING AIR m³/sec 200 cfm m³/sec 250 cfm VOLTAGE SERIES STAR 380/ / / / / / / /277 VOLTAGE PARALLEL STAR 190/ / / / / / / /138 VOLTAGE SERIES DELTA 220/ / / / / / / /138 kva BASE RATING FOR REACTANCE VALUES Xd DIR. AXIS SYNCHRONOUS X'd DIR. AXIS TRANSIENT X''d DIR. AXIS SUBTRANSIENT Xq QUAD. AXIS REACTANCE X''q QUAD. AXIS SUBTRANSIENT XL LEAKAGE REACTANCE X2 NEGATIVE SEQUENCE X0 ZERO SEQUENCE REACTANCES ARE SATURATED T'd TRANSIENT TIME CONST. T''d SUB-TRANSTIME CONST. T'do O.C. FIELD TIME CONST. Ta ARMATURE TIME CONST. SHORT CIRCUIT RATIO VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED 0.02 s s 0.4 s s 1/Xd 3
4 50 BCI184E Winding 311 THREE PHASE EFFICIENCY CURVES 4
5 BCI184E Winding 311 THREE PHASE EFFICIENCY CURVES 60 5
6 30 50 BCI184E Winding 311 Locked Rotor Motor Starting Curve 346V 380V 400V 415V 440V 25 PER CENT TRANSIENT VOLTAGE DIP LOCKED ROTOR kva V 416V 440V V 25 PER CENT TRANSIENT VOLTAGE DIP LOCKED ROTOR kva 6
7 BCI184E Page left blank intentionally 7
8 50 Class - Temp Rise BCI184E Winding 311 / 0.8 Power Factor RATINGS Cont. F - 105/40 C Cont. H - 125/40 C Standby - 150/40 C Standby - 163/27 C Series Star (V) Parallel Star (V) Series Delta (V) kva kw Efficiency (%) kw Input N/A N/A 60 Series Star (V) Parallel Star (V) Series Delta (V) kva kw Efficiency (%) kw Input N/A N/A DIMENSIONS 2004 Newage International Limited. Reprinted with permission of N.I. only. Printed in England. Barnack Road Stamford Lincolnshire PE9 2NB Tel: (0) Fax: (0) Website: TD_BCI184E.GB_12.03_03_GB
UCI274C - Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000,
UCI274H - Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000,
PI734D - Technical Data Sheet
PI734D - Technical Data Sheet PI734D SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international
PI734B - Technical Data Sheet
PI734B - Technical Data Sheet PI734B SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international
PM734F - Technical Data Sheet Winding 28
- Technical Data Sheet Winding 28 SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international standards, including
PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS
PI144K - Winding 311 Technical Data Sheet PI144K SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section
PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
PI044E - Winding 311 Technical Data Sheet PI044E SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
HCM434F - Winding 311 Technical Data Sheet HCM434F SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards
3790 en - 06.2007 / d. Alternators LSA 46.2-4 Pole. Electrical and mechanical data
379 en - 6.7 / d Alternators LSA 46.2-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 46.2 alternator is designed to be suitable for typical generator applications, such
IGSA POWER GENERATION SYSTEMS
IGSA POWER GENERATION SYSTEMS MODEL: GSDD20600S. MTU, 12V1600G80S, 1800 RPM, 60 HZ. CAPACITY KW KVA 600 750 Reference Conditions ISO 3046: Intake air temperature Side altitude above sea level Charge air
STAMFORD Product Guide
Product Guide MOVE 2005 7/11/06 15:46 Page 1 STAMFORD Product Guide R There for you TM Versatile, robust and reliable brushless ac generators up to 2750kVA Product Guide MOVE 2005 7/11/06 15:46 Page 2
CUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 2806A-E18TAG2 diesel engine Newage/Stamford HCI544F alternator Standard Generator Features AMF, Automatic mains failure unit Heavy
32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw
,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted
Effective: September 10, 2006 Vermont Attachment 1 to Rule 5.500 Public Service Board Page 1 of 6
Public Service Board Page 1 of 6 STANDARD APPLICATION FOR INTERCONNECTION OF GENERATION RESOURCES IN PARALLEL TO THE ELECTRIC SYSTEM OF: (Interconnecting Utility) Preamble and Instructions: An owner of
SYNCHRONOUS MACHINES
SYNCHRONOUS MACHINES The geometry of a synchronous machine is quite similar to that of the induction machine. The stator core and windings of a three-phase synchronous machine are practically identical
Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection
Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection (See ARSD chapter 20:10:36 for the requirements for a Tier 2, Tier 3, or Tier 4 Interconnection.) Applicant/Interconnection
CUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 4006-23TAG3A diesel engine Stamford HCI 634 H alternator Standard Generator Features AMF, Automatic mains failure unit Heavy duty
CUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 4006-23TAG2A diesel engine Newage/Stamford HCI634G alternator Standard Generator Features AMF, Automatic mains failure unit Heavy
Physical Address: City: State: Zip Code:
Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection (For Small Generator Facilities with Electric Nameplate Capacities of 10 MW and less) Applicant Contact
TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET
TECHNICAL DATA DIESEL GENERATING SET MPMC POWERTECH CORP. 60HZ MC Series MCS600S-2 / MCS600-2 MCS600S-2/ MCS600-2 MC Series Features Reference images, the actual shall prevail Compact structure with high-strength
DIESEL GENERATOR SETS
DIESEL SETS STANDBY Standby Prime Model kw (kva) kw (kva) D175-2* 175 (218.8) 157.5 (196.9) *Tier 3 EPA Approved, Emissions Certified Picture shown may not reflect actual package FEATURES SET Complete
CUMMINS SERIE 6B. Definiciónes. Potencia Prime. Potencia Stand by. Estos valores son aplicables para el suministro de energía eléctrica continua
CUMMINS SERIE 6B Definiciónes Potencia Prime Estos valores son aplicables para el suministro de energía eléctrica continua (a carga variable) en lugar de la red comercial + 10% sobrecarga Potencia Stand
ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only
ATTACHMENT F CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 20 KW BUT LESS THAN OR EQUAL TO 150 KW Also Serves as Application for Category
AC-Synchronous Generator
Design Description AC Generators come in two basic types synchronous and non-synchronous. Synchronous generators lock in with the fundamental line frequency and rotate at a synchronous speed related to
TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET
TECHNICAL DATA DIESEL GENERATING SET MPMC POWERTECH CORP. 50HZ MP Series MPS180S 1 / MPS180 1 MPS180S 1 / MPS180 1 MP Series Features Compact structure with high strength chassis; Easy operation and maintenance,
CUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 4016TAG2A diesel engine Newage/Stamford PI734F alternator Standard Generator Features AMF, Automatic mains failure unit Heavy duty
Automatic Voltage Regulator User s Manual
Resp. dept. R&D We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Copyright
Basics of Electricity
Basics of Electricity Generator Theory PJM State & Member Training Dept. PJM 2014 8/6/2013 Objectives The student will be able to: Describe the process of electromagnetic induction Identify the major components
FAULT FINDING MANUAL. For Stamford AC Generators
FAULT FINDING MANUAL For Stamford AC Generators 1 SAFETY PRECAUTIONS Test procedures recommended in this manual assume that the reader is fully conversant with electrical safety principles, and is familiar
PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP
PacifiCorp Original Sheet No. 476 APPENDIX 2 TO SGIP SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) Transmission Provider: Designated Contact Person: Address: Telephone Number: An Interconnection
DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE2302 - ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR
1 DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING Constructional details Types of rotors EE2302 - ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR PART A 1.
DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET
DIESEL SET STANDBY Model Standby Prime kw (kva) kw (kva) D40-4 40 (50) 36 (45) D40-4S 40 (40) 36 (36) D50-4 50 (62.5) 45 (56.3) D50-4S 50 (50) 45 (45) D60-4 60 (75) 54.6 (68.2) All models are Tier II EPA
WIND TURBINE TECHNOLOGY
Module 2.2-2 WIND TURBINE TECHNOLOGY Electrical System Gerhard J. Gerdes Workshop on Renewable Energies November 14-25, 2005 Nadi, Republic of the Fiji Islands Contents Module 2.2 Types of generator systems
R448 & R448 V50 A.V.R.
Armature + 6- This manual is to be given to the end user F1 ST5 Field Slow fuse 250V 10 A with LAM without LAM 10 Yellow 11 Red 12 Black 9 Green X2 Z1 X1 Z2 E+ E- 0V 110 22 ST3 requency ST10 50Hz 60Hz
Lab 8: DC generators: shunt, series, and compounded.
Lab 8: DC generators: shunt, series, and compounded. Objective: to study the properties of DC generators under no-load and full-load conditions; to learn how to connect these generators; to obtain their
CUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 4012-46TAG2A diesel engine Newage/Stamford PI734C alternator Standard Generator Features AMF, Automatic mains failure unit Heavy
Diesel Generator Set Model DFHC 60 Hz
Diesel Generator Set Model DFHC 60 Hz 900 kw, 1125 kva Standby 818 kw, 1023 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power generation
GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer
D I E S E L G E N E R A T O R S E T GEP550 (3-Phase) 50 HZ STANDBY PRIME 550 kva / 440 kw 500 kva / 400 kw FEATURES GENERATOR SET Complete system designed and built at ISO9001 certified facility Factory
Generators TEM. for small hydroelectric power stations. Electric Machines
Generators for small hydroelectric power stations TEM Electric Machines Advanced solutions for the cleanest energy Reputable manufacturer of generators for small hydroelectric power stations TED Electric
Diesel Generator Set Model DFMB 60 Hz
Diesel Generator Set Model DFMB 60 Hz 1500 kw, 1875 kva Standby 1250 kw, 1563 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power generation
Keywords: synchronous generator, synchronous motor, automatic voltage regulator, V- curves, synchronizing power, hunting, excitation system
SYNCHRONOUS MACHINES Tze-Fun Chan Hong Kong Polytechnic University, Hong Kong, China Keywords: synchronous generator, synchronous motor, automatic voltage regulator, V- curves, synchronizing power, hunting,
Paralleling Power Sources Which Share a Common Neutral
Paralleling Power Sources Which Share a Common Neutral By: Tony Hoevenaars, P.E., President & CEO, Mirus International, Inc. Mike McGraw, President, NSOEM, Inc. When paralleling power sources that share
Mounting Instructions. Torque Transducer. A0329 3.2 en
Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................
Verification of Short Circuit Test Results of Salient Poles Synchronous Generator
Verification of Short Circuit Test Results of Salient Poles Synchronous Generator Abdul Jabbar Khan 1, Amjadullah Khattak 2 1 PG Student, University of Engineering and Technology, Peshawar, Department
Rules for Classification and Construction Additional Rules and Guidelines
VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 6 Test Requirements for Electrical Machinery Edition 1999 The following Guidelines
Spark-ignited generator set
Specification sheet Spark-ignited generator set 30 60 kw standby EPA emissions Description Cummins Power Generation commercial generator sets are fully integrated power generation systems providing optimum
FIT TIER 2 Application
FIT TIER 2 Application Application Information The below information Auto-Fills from your registration information: Building Permit Application Date: Project Completion Date: Name: Address: City: State:
R438 A.V.R. Installation and maintenance R 438. This manual is to be given to. the end user T10. Armature 6- Field X2 Z1 X1 Z2 E+ E- 0V 110 220
Armature 6- This manual is to be given to the end user 1 T5 Field Slow fuse 250V 8 A with LAM without LAM 10 Yellow 11 Red 12 Black 9 Green X2 Z1 X1 Z2 E+ E- 0V 110 220 T3 quency T10 50Hz 60Hz LAM 13 %
Single-Phase AC Synchronous Generator
ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description
GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer
D I E S E L G E N E R A T I N G S E T GEP150 (3-Phase) 50 HZ STANDBY PRIME 60 HZ STANDBY PRIME 150 kva / 120 kw 135 kva / 108 kw 165 kva / 132 kw 150 kva / 120 kw FEATURES GENERATING SET Complete system
Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques
Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques Howard W. Penrose, Ph.D On behalf of ALL-TEST Pro, LLC Old Saybrook, CT Introduction Field and shop testing of
Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP
Grid Interconnection & Contract Development Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP Submittal Instructions Prior to submitting your application and
FAULT FINDING MANUAL For Self Excited and Separately Excited Generators
FAULT FINDING MANUAL For Self Excited and Separately Excited Generators SAFETY PRECAUTIONS Before testing the generating set, read the generating set Installation Manual, and this Fault Finding Manual,
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?
Extra Questions - 2 1. A straight length of wire moves through a uniform magnetic field. The e.m.f. produced across the ends of the wire will be maximum if it moves: a) along the lines of magnetic flux
32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw
,QGXVWULDO#*HQHUDWRU 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw Generator set consisting of engine and alternator mounted
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
Torque motors. direct drive technology
Torque motors direct drive technology Why Direct Drive Motors? Fast and effective Direct-drive technology in mechanical engineering is defined as the use of actuators which transfer their power directly
Diesel Generator Set Model DGDK 60 Hz
Diesel Generator Set Model DGDK 60 Hz 125 kw, 156 kva Standby 113 kw, 141 kva Prime Description The Cummins Power Generation DG-series commercial generator set is a fully integrated power generation system
CUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 4008TAG2A diesel engine Stamford HCI634J alternator Standard Generator Features AMF, Automatic mains failure unit Heavy duty type,
The reliability of the grid
Power topic #9019 Technical information from Cummins Power Generation Power system considerations for cell tower applications White Paper By Wissam Balshe, Group Leader, Sales Application Engineering Industry
FREQUENCY CONTROLLED AC MOTOR DRIVE
FREQUENCY CONTROLLED AC MOTOR DRIVE 1.0 Features of Standard AC Motors The squirrel cage induction motor is the electrical motor motor type most widely used in industry. This leading position results mainly
DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw
DLW 8 POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw Generator set consisting of engine and alternator mounted on a fabricated steel
How To Control A Power Command Powerplant
Diesel Generator Set Model DFEJ 60 Hz EPA Emissions 450 kw, 563 kva Standby 410 kw, 513 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power
Type SA-1 Generator Differential Relay
ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065 Instruction Leaflet 41-348.11C Effective: November 1999 Supersedes I.L. 41-348.11B, Dated August 1986 ( ) Denotes
SUNON SPECIFICATION FOR APPROVAL
SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X25 mm M O D E L : KDE2406PTB2 APPROVED NO : APPROVED BY : (AUTHORZIED) SPEC.NO D600732 ISSUE DATE 10.01.1998 DAWN.
Offshore Platform Powered With New Electrical Motor Drive System
Offshore Platform Powered With New Electrical Motor Drive System Authors: Jan O. Lamell, M.Sc E.E. ABB Automation Technologies Presenters: Thomas Johansson, M.Sc E.E. ABB Automation Technologies Timothy
Solving VFD-sourced Bearing Current Problems in AC Motors.
Solving VFD-sourced Bearing Current Problems in AC Motors. The 2 main sources of motor shaft voltage are: 1. Asymmetric Motor construction The stator and rotor magnetic circuits within the motor itself
SX460. Generator Automatic Voltage Regulator Operation Manual
SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.
Power Quality Paper #3
The Effect of Voltage Dips On Induction Motors by: M D McCulloch 1. INTRODUCTION Voltage depressions caused by faults on the system affect the performance of induction motors, in terms of the production
REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)
SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual
PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual A Regal Brand TABLE OF CONTENTS INTRODUCTION 2 General Data 2 Initial Inspection 2 SAFETY 2 INSTALLATION 3 Location / Environment
Synchronous motor. Type. Non-excited motors
Synchronous motor A synchronous electric motor is an AC motor in which the rotation rate of the shaft is synchronized with the frequency of the AC supply current; the rotation period is exactly equal to
Principles of Adjustable Frequency Drives
What is an Adjustable Frequency Drive? An adjustable frequency drive is a system for controlling the speed of an AC motor by controlling the frequency of the power supplied to the motor. A basic adjustable
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
C Standard AC Motors
C Standard AC Standard AC C-1 Overview, Product Series... C-2 Constant... C-9 C-21 C-113 Reversible C-147 Overview, Product Series Constant Reversible Electromagnetic Brake C-155 Electromagnetic Brake
ST Style Generator. Owners/Operators Manual
ST Style Generator Owners/Operators Manual LLC 216 Airport Rd NE Milledgeville, GA 31061 478-453-9358-Office 478-457-5524- Tom Cell 478-251-2914- Chris Cell Table of Contents Page 2. Table of Contents
Harmonics in your electrical system
Harmonics in your electrical system What they are, how they can be harmful, and what to do about them Abstract Harmonic currents, generated by non-linear electronic loads, increase power system heat losses
Welcome to Linear Controls Quarterly Training
Welcome to Linear Controls Quarterly Training Introduction to Power Generation Objectives Supply attendees with basic knowledge of power generators and voltage regulators and provide the fundamentals of
SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
COMPUTER AIDED ELECTRICAL DRAWING (CAED) 10EE65
COMPUTER AIDED ELECTRICAL DRAWING (CAED) EE Winding Diagrams: (i) DC Winding diagrams (ii) AC Winding Diagrams Terminologies used in winding diagrams: Conductor: An individual piece of wire placed in the
TABLE OF CONTENTS INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES...
SYNCHRONOUS MOTORS TABLE OF CONTENTS Motores Síncronos INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES...11 CONSTRUCTIVE CHARACTERISTICS...12
ET 332b Ac Electric Machines and Power Systems
Instructor: Dr. Carl Spezia, PE Office: Engr. D110 Phone: 453-7839 E-mail: [email protected] ET 332b Ac Electric Machines and Power Systems Office Hours: 9:00 am - 10:00 am M-W-F 2:00 pm - 3:00 pm M-W-F
Annex-A TECHNICAL SPECIFICATION
Annex-A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 0.4kV (2,000kVA) DIESEL GENERATOR 1 1.0 SCOPE This specification covers the requirements of design, manufacture, delivery
SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2
SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 APPROVED NO : APPROVED BY : (AUTHORIZED) SPEC.NO D600023 ISSUE DATE 08.06.1998 DAWN.
GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta
GENERATOR SELECTION Generators must be sized to handle their load based on the continuous KW, kilowatt load, and KVA, kilovoltamp load, and the worst case starting load KW + KVA. They must be derated for
Understanding the Alternator
http://www.autoshop101.com THIS AUTOMOTIVE SERIES ON ALTERNATORS HAS BEEN DEVELOPED BY KEVIN R. SULLIVAN PROFESSOR OF AUTOMOTIVE TECHNOLOGY AT SKYLINE COLLEGE SAN BRUNO, CALIFORNIA ALL RIGHTS RESERVED
ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION
ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION SC ELECTROPUTERE SA SC ELECTROPUTERE SA 1. Vision, Mission, Values SC ELECTROPUTERE SA 2. LOCATION Craiova: Located in the South West of the country,
Motor Fundamentals. DC Motor
Motor Fundamentals Before we can examine the function of a drive, we must understand the basic operation of the motor. It is used to convert the electrical energy, supplied by the controller, to mechanical
3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives
3753 en 04.2004/b Variable speed drives LEROYSOMER's drives provide SPEED VARIATION for a DC motor, SIMPLY and ECONOMICALLY from a singlephase power supply. CMStype technology is used. These products conform
Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP
Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP ABB The Preferred Partner Egypt Cement Corporation, a major cement manufacturer, has chosen ABB wound rotor motors for all key applications
DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION
ÿþ üûúùø öõöôùóùõò CT Dimensioning DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION Application note GER3973 1 CT Dimensioning ÿþ üûúùø öõöôùóùõò GER-3973 Application note ÿþ üûúùø öõöôùóùõò
SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION
SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION Introduction Howard W. Penrose, Ph.D., CMRP Vice President, Engineering and Reliability Services Dreisilker Electric Motors, Inc.
How the efficiency of induction motor is measured?
How the efficiency of induction motor is measured? S. Corino E. Romero L.F. Mantilla Department of Electrical Engineering and Energy E.T.S.I.I. y T. Universidad de Cantabria Avda de Los Castros, 395 Santander
ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) 41-161J. Instruction Leaflet
ABB Instruction Leaflet 41-161J Effective: May 1997 Supersedes I.L. 41-161H Dated July 1984 ( ) Denotes Change Since Previous Issue Type COQ Negative Sequence Generator Relay (50/60 Hertz)! CAUTION Before
Circulating Current Relay. Type IRXm
Circulating Current Relay Type IRXm ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering
Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO 250447392
1 Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading By Ramandeep Kaur Aujla S.NO 250447392 ES 586b: Theory and applications of protective relays Department of
INSTALLATION, SERVICE AND MAINTENANCE MANUAL
UC Alternators INSTALLATION, SERVICE AND MAINTENANCE MANUAL English Original Instructions A040J848 (Issue 5) Table of Contents 1. FOREWORD... 1 2. SAFETY PRECAUTIONS... 3 3. SAFETY DIRECTIVES AND STANDARDS...
Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.
Lab 9: Synchronous motor. Objective: to examine the design of a 3-phase synchronous motor; to learn how to connect it; to obtain its starting characteristic; to determine the full-load characteristic of