Installation Instructions



Similar documents
Compact I/O End Caps/Terminators

POINT I/O 24V dc Expansion Power Supply

Micro " LCD Display and Keypad Module

CompactLogix Power Supplies Specifications

Installation Instructions. FLEX I/O Isolated Input Analog Module Cat. No IF4I

Installation Instructions. FLEX I/O DeviceNet Adapter Module 1794-ADN Series C and 1794-ADNK Series C

Micro810 USB Adapter. Wiring Diagrams. Catalog Number 2080-USBADAPTER

POINT I/O EtherNet/IP Adapter

POINT I/O 8 Channel High Density Current Input Module

FLEX I/O Digital Input Modules

MicroLogix 1762-IF4 Analog Input Module

EtherNet/IP Modules. Installation Instructions

Installation Instructions. DeviceNet Modules. Catalog Numbers 1756-DNB, 1769-ADN, 1769-SDN

POINT I/O Input Modules

1788 Linking Device Specifications

SLC 500 Analog Input Module

1756 ControlLogix Chassis Specifications

Compact I/O Expansion Power Supplies

Backup Scanner Module

1756 ControlLogix Integrated Motion Modules Specifications

USB-to-Data Highway Plus Cable

1769-L35E CompactLogix Controller

1756 ControlLogix I/O Specifications

1756 ControlLogix Power Supplies Specifications

SLC 500 Digital I/O Modules

Ethernet-to-DeviceNet Linking Device

XM-160/161/162 Direct Vibration Module

Chassis Interface Module for 1746 Local I/O (Catalog Number 1747-PCIL)

MicroLogix 1400 Programmable Controllers

ControlNet Standard and High-flex Coax Cable

Ethernet PLC-5 Programmable Controllers

Installation Instructions

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

1769 CompactLogix Controllers User Manual

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Compact I/O High-speed Counter Module

Installation Instructions

FLEX I/O High-Density Analog Modules

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Installation Instructions

Micro Point Programmable Controllers

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Rosemount 333 HART Tri-Loop

Micro800 Programmable Controller Family. Bulletin 2080 Selection Guide

Rosemount 333 HART Tri-Loop

1769 Compact I/O Modules Specifications

Installation Instructions. Before Installation. Read these installation instructions carefully before commissioning the pressure transmitter.

Bimetallic Overload Relay Specifications

FLEX I/O Isolated Analog Modules

SLC 500 BASIC and BASIC-T Modules

Universal Serial Bus (USB) to DH-485 Interface Converter

38 Series - Relay interface modules A

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Analog signal converters CC-E I/I Current / current isolators

NGC-30-CR -CRM -CRMS -CTM -CVM

Table 24 - Environmental Specifications M Performance Monitors. NEMA/UL 50 Type 1, 4, 4X, 12, and IEC IP66

Micro820 Programmable Controllers

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

AAV003-10E Current Sensor

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Telephone- and leased line modem for industrial applications TD-36

NI USB-5681 RF Power Meter Specifications

Technical Note Series

Digital input modules

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

EtherNet/IP and ControlNet to PROFIBUS PA Linking Devices

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

38 Series - Relay interface modules A

STRATO LED Drivers 70W, Single output

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

ACS-CRM CONTROL AND MONITORING MODULES FOR USE WITH THE RAYCHEM ACS-30 SYSTEM INSTALLATION INSTRUCTIONS

Foxboro Evo Process Automation System

Allen-Bradley/Rockwell

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

MasterINTERFACE 39 Series - Relay interface modules

Redundancy Module QUINT-DIODE/40

DeltaV SISnet Repeater

Fiber Optic Cable Installation

LOXONE 12 Channel Amplifier

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

3500/62 Process Variable Monitor

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

DS 600. A contact free flux gate based current measurement sensor 600A rms

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Power Supplies 3. SDN-P DIN Rail Series

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

FEMA ELECTRÓNICA. Serie ISC SIGNAL CONVERTERS WITH GALVANIC ISOLATION. MODEL ISC-IAC for AC Currents ISC-IDC for DC Currents USER S MANUAL

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Transcription:

Installation Instructions LEX I/O Input, and Input/ Analog odules at. Nos. 9-IE8, -IE8K, -OE, -OEK, and -IEXOE Series B (odules with a K in the last position of the catalog number are conformally coated to meet noxious gas requirements of ISA/ANSI-. 98 lass G Environment.) Important ser Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and aintenance of Solid State ontrols (Publication SGI-. available from your local Rockwell Automation sales office or online at http://www.ab.com/manuals/gi) describes some important differences between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. he examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc. is prohibited. hroughout this manual we use notes to make you aware of safety considerations. Identifies information about practices or circumstances that can cause an ARNING explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. IPORAN ARNING Identifies information that is critical for successful application and understanding of the product. Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you: identify a hazard avoid a hazard recognize the consequence European Zone Hazardous Location Approval he following analog input/output modules are European Zone approved: 9-IE8/B, 9-IE8K/B, 9-OE/B, 9-OEK/B and 9-IEXOE/B. ARNING IPORAN O Publication 9-INB-EN-P - June

North American Hazardous Location Approval he following modules are North American Hazardous Location approved: 9-IE8/B, 9-IE8K/B, 9-OE/B, 9-OEK/B and 9-IEXOE/B. he following information applies when operating this equipment in hazardous locations: Products marked L I, DIV, GP A, B,, D are suitable for use in lass I Division Groups A, B,, D, Hazardous Locations and nonhazardous locations only. Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code. hen combining products within a system, the most adverse temperature code (lowest number) may be used to help determine the overall temperature code of the system. ombinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of installation. ARNING Installing Your Analog Input/ odule EXPLOSION HAZARD Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous. Do not disconnect connections to this equipment unless power has been removed or the area is known to be nonhazardous. Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this product. Substitution of components may impair suitability for lass I, Division. If this product contains batteries, they must only be changed in an area known to be nonhazardous. Informations sur l utilisation de cet équipement en environnements dangereux : Les produits marqués "L I, DIV, GP A, B,, D" ne conviennent qu à une utilisation en environnements de lasse I Division Groupes A, B,, D dangereux et non dangereux. haque produit est livré avec des marquages sur sa plaque d identification qui indiquent le code de température pour les environnements dangereux. Lorsque plusieurs produits sont combinés dans un système, le code de température le plus défavorable (code de température le plus faible) peut être utilisé pour déterminer le code de température global du système. Les combinaisons d équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l installation. AVERISSEEN RISQE D EXPLOSION ouper le courant ou s assurer que l environnement est classé non dangereux avant de débrancher l'équipement. ouper le courant ou s'assurer que l environnement est classé non dangereux avant de débrancher les connecteurs. ixer tous les connecteurs externes reliés à cet équipement à l'aide de vis, loquets coulissants, connecteurs filetés ou autres moyens fournis avec ce produit. La substitution de composants peut rendre cet équipement inadapté à une utilisation en environnement de lasse I, Division. S assurer que l environnement est classé non dangereux avant de changer les piles. hannel Input Input Input Input Input Input Input Input -V dc ommon V dc Power hassis Ground (Shield) Signal ype Label arking 9 -B, -B, -BS, -B, -BS, 9 -B, -BS 9 -B, B, -BS 9-B, -BS Input Power ommon erminal Shield urrent I A- - B- B- V A- - B-8 B- -9 urrent I A- - B-9 B-9 V A- -8 B- B-9 - urrent I A- -9 B- B- V A- - B- B- - urrent I A- - B- B- V A- - B- B- - urrent I A-8 - B- B- V A-9 - B- B- - urrent I A- - B- B- V A- - B-8 B- - urrent I A- - B-9 B-9 V A- -8 B- B-9 - urrent I A- -9 B- B- V A- - B- B- - 9-B, -B, -BS - erminals thru are internally connected in the terminal base unit. 9-B, -BS - erminals,, 9,,,,, 9, and are internally connected in the terminal base unit. 9-B, -BS - erminals thru are internally connected in the terminal base unit. 9-B, -BS - erminals,, and are internally connected in the terminal base unit. 9-B - erminals and are internally connected in the terminal base unit. 9-B, -BS - erminals 9 thru are internally connected to chassis ground. se when transmitter requires terminal base power. onnecting iring for the Analog Inputs and s IPORAN Publication 9-INB-EN-P - June

I V I V I V I V I V I V I V I V 8 9 8 9 A - Input 8 9 8 9 B - V ommon 8 9 8 9 - V Power i ac or dc - ire urrent (External power) hannel Signal ype Label arking 9-B, -B, -BS, -B, -BS erminal Shield (9-B, -BS 9-BN erminal urrent I A- B- -9 urrent I Ret A- - V A- B- - V Ret A- - urrent I A- B- - urrent I Ret A- - V A- B- - V Ret A- - urrent I A-8 B-8 - urrent I Ret A-9-9 V A- B- - V Ret A- - urrent I A- B- - urrent I Ret A- - V A- B- - V Ret A- - -V dc ommon 9-B, -BS - erminals thru are internally connected in the terminal base unit. 9-B, -BS - erminals,, 9,,,,, 9, and are internally connected in the terminal base unit. 9-B - erminals and are internally connected in the terminal base unit V dc Power 9-B, -BS - erminals thru are internally connected in the terminal base unit. 9-B, -BS - erminals,, and are internally connected in the terminal base unit. 9-B - erminals and are internally connected in the terminal base unit. hassis Ground (Shield) ac or dc - ire (External power) - - ire ( erminal base powered - ire urrent ( erminal base powered loop) (9-B base shown) 9-B, -BS - erminals 9 thru are internally connected to chassis ground. A-,,,, 9,, and are internally connected in the module to V dc common. -,,,, 9,, and are internally connected in the module to V dc common i Even Numbered erminals thru Row B 8,,,,, 8,,,, 9 Row,,,,, 9,,,, I urrent _ urrent only -ire hannel Input Input Input Input -V dc ommon V dc Power hassis Ground (Shield) Signal ype I _ dc only -ire Label arking 9-B, -B,-BS, -B, -BS Input/ erminal 9 -B, -BS Power erminal 9 -B, -B, -BS ommon erminal urrent I A- - B- B- V A- - B-8 B- urrent I A- - B-9 B-9 V A- -8 B- B-9 urrent I A- -9 B- B- V A- - B- B- urrent I A- - B- B- V A- - B- B- urrent I A-8 urrent RE A-9 V A- RE A- urrent I A- urrent RE A- V A- RE A- I I urrent _ urrent only -ire 9-BN dc only shown -ire 9-B, -BS Shield -9 - - - - - - - 9-B, -B, -BS - erminals thru are internally connected in the terminal base unit. 9-B, -BS - erminals,, 9,,,,, 9, and are internally connected in the terminal base unit. 9-B, -BS - erminals thru are internally connected in the terminal base unit. 9-B, -BS - erminals,, and are internally connected in the terminal base unit. 9-B - erminals and are internally connected in the terminal base unit. 9-B, -BS - erminals 9 thru are internally connected to chassis ground. A-9,, and are internally connected in the module to V dc common. se when transmitter requires terminal base power. I V I V I V I V 8 9 8 9 8 9 8 9 8 9 8 9 I urrent Input ac or dc -ire urrent ransmitter I Input dc only -ire ransmitter I R V R I R V R I I urrent urrent only -ire dc only -ire _ A B Publication 9-INB-EN-P - June

Input ap (Read) - 9-IE8, -IE8K Dec. 9 8 Oct. ord S Analog Input Value for hannel ord S Analog Input Value for hannel ord S Analog Input Value for hannel ord S Analog Input Value for hannel ord S Analog Input Value for hannel ord S Analog Input Value for hannel ord S Analog Input Value for hannel ord S Analog Input Value for hannel ord 8 P Not used - set to zero here :P = Power up inconfigured S = Sign bit (in s complement) = nderrange for specified channel ap (rite) - 9-IE8, -IE8K Dec. 9 8 Oct. ord here : = onfigure select bit = ull range bit Input ap (Read) - 9-IEXOE Dec. 9 8 Oct. ord S Analog Input Value for hannel ord S Analog Input Value for hannel ord S Analog Input Value for hannel ord S Analog Input Value for hannel ord P Not used - set to zero here :P = Power up inconfigured S = Sign bit (in s complement) and = Diagnostic bits for current output. ire off current loop status for output channels and = nderrange for specified channel ap (rite) - 9-IEXOE Dec. 9 8 Oct. ord S Analog Data - hannel ord S Analog Data - hannel ord Not used - set to ord Range Selection Bits - 9-IE8, -IE8K and -IEXOE ords and Not used - set to ord Safe State Value for hannel ord Safe State Value for hannel here : P = Power up inconfigured P = ield power off = In configuration mode BD = Bad calibration DN = alibration accepted and = ire off current loop status for output channels and = nderrange for specified channel V = Overrange for specified channel P and P = s holding in response to Q and Q 9-IE8 In h. In h. In h. In h. In h. In h. In h. In h. 9- In h. In h. In h. In h. Out h. Out h. IEXOE Dec. Bits 8 9 -V dc/ -ma -ma - to V dc O here: = onfigure Select Bit = ull range hen configured to Off, individual input channels will return H; output channels will drive V/mA. Input ap (Read) - 9-OE, -OEK Dec. 9 8 Oct. ord P Not used - set to here : P = Power up bit thru = ire off current loop status for output channels ap (rite) - 9-OE, -OEK Dec. 9 8 Oct. ord S Data hannel ord S Data hannel ord S Data hannel ord S Data hannel ord Not used - set to ord Not used - set to Not used - set to ord -9 Not used - set to ord S Safe state value for hannel ord S Safe state value for hannel ord S Safe state value for hannel ord S Safe state value for hannel here : S = Sign bit (in s complement) = ultiplex control bit = onfigure select bit = ull range bit Range Selection Bits - 9-OE, -OEK hannel No. In h. In h. In h. In h. Dec. Bits 8 9 -V dc/ -ma -ma - to V dc O here: = onfigure Select Bit = ull range hen configured to Off, individual output channels will drive V/mA. Specifications Input Specifications Number of Inputs Resolution urrent Data ormat onversion ype onversion Rate Input urrent erminal Input erminal Normal ode Rejection Ratio - erminal urrent erminal Step Response to % - Input Impedance Input Resistance 9-IE8, -IE8K - 8 single-ended, nonisolated 9-IEXOE - single-ended nonisolated bits unipolar; bits plus sign bipolar.mv/cnt unipolar;.mv/cnt bipolar.μa/cnt left justified, bit s complement successive approximation μs all channels -ma (user configurable -ma (user configurable V (user configurable) -V (user configurable) db @ Hz; -db/decade -db @ Hz;-.db @ Hz -db @ 9Hz; -db/decade -.db @ Hz;-.8db @ Hz erminal - 9.ms urrent erminal - 8.ms erminal - k ohms urrent erminal - 8 ohms erminal - k ohms urrent erminal - 8 ohms Absolute Accuracy.% ull Scale @ Accuracy Drift with emperature alibration Required aximum Overload Indicators erminal -.8% ull Scale/ urrent erminal -.% ull Scale/ None required V continuous or ma continuous, one channel at a time. green power indicator Publication 9-INB-EN-P - June

Specifications Number of s Resolution urrent Data ormat onversion ype urrent erminal erminal Step Response to % - or urrent erminal urrent Load on voltage output Absolute Accuracy erminal urrent erminal Accuracy Drift with emperature erminal urrent erminal Resistive Load on ma 9-OE, -OEK - single-ended, nonisolated 9-IEXOE - single-ended, nonisolated bits plus sign.mv/cnt.μα/cnt left justified, bit s complement Pulse width modulation ma output until module is configured -ma (user configurable -ma (user configurable V output until module is configured V (user configurable) -V user configurable) ms ma maximum.% ull Scale @.% ull Scale @.% ull Scale/.9% ull Scale/ - ohm @ V dc General Specifications for 9-IE8, -IE8K, -OE, -OEK, and -IEXOE odule Location at. No. 9-IE8, -IE8K, -IEXOE - 9-B, -B, -BS, -B, -BS erminal Base nit at. No. 9-OE, -OEK - 9-B, -B, -BS, -B, -BS, and -BN erminal Base nit erminal Base Screw orque pound-inches (.8Nm) 9 pound-inches (.Nm) for 9-BN Isolation ested at 8V dc for s between user power to system No isolation between individual channels External dc Power Supply Range Supply urrent Dimensions (with module installed) lexbus urrent Power Dissipation hermal Dissipation V dc nominal. to.v dc (includes % ac ripple) 9-IE8, -IB8K - ma @ V dc; ma @ V dc 9-OE, -OEK - ma @ V dc; ma @ V dc 9-IEXOE - ma @ V dc; ma @ V dc.8h x. x.d inches.h x 9 x.d mm ma 9-IE8, -IB8K -. maximum @.V dc 9-OE, -OEK -. maximum @.V dc 9-IEXOE -. maximum @.V dc 9-IE8, -IB8K - aximum. B/hr @.V dc 9-OE, -OEK - aximum. B/hr @.V dc 9-IEXOE - aximum. B/hr @.V d Keyswitch Position 9-IE8, -IB8K - 9-OE, -OEK - 9-IEXOE - Environmental onditions Operating emperature IE 8-- (est Ad, Operating old), IE 8-- (est Bd, Operating Dry Heat), IE 8-- (est Nb, Operating hermal Shock): to ( to ) Storage emperature IE 8-- (est Ab, n-packaged Non-operating old), IE 8-- (est Bb, n-packaged Non-operating Dry Heat), IE 8-- (est Na, n-packaged Non-operating hermal Shock): to 8 ( to 8 ) Relative Humidity IE 8-- (est Db, npackaged Nonoperating Damp Heat): to 9% non-condensing Vibration IE8-- (est c, Operating): g @ -Hz Shock IE8-- (est Ea, npackaged shock): Operating g Non-operating g Emissions ISPR Group, lass A (with appropriate enclosure) ESD Immunity E --: kv contact discharges 8kV air discharges Radiated R Immunity IE --: V/m with khz sine-wave 8%A from Hz to Hz onducted R Immunity IE --: V rms with with khz sine-wave 8%A from khz to Hz E/B Immunity IE --: ±kv at khz on signal ports Surge ransient Immunity Enclosure ype Rating onductors ire Size IE --: ±kv line-earth () on shielded ports None (open-style) -AG (.mm -.mm ) stranded copper wire rated at or higher / inch (.mm) insulation maximum ategory ertifications (when product L L Listed Industrial ontrol Equipment is marked) L L Listed for lass I, Division Group A,B,,D Hazardous Locations LSL Listed Industrial ontrol Equipment, certified for S and anada (9-IE8, -OE) L L Listed for lass I, Division Group A,B,,D Hazardous Locations, certified for anada (9-IE8, -IE8K, -OE, -OEK) SA SA certified Process ontrol Equipment SA SA certified for lass I, Division, Groups A, B, and D Hazardous locations EEx European nion 9/9/EE AEX Directive, compliant with: EN ; Potentially Explosive Atmospheres, Protection n (European Zone ) E European nion 89//EE E Directive, compliant with: EN --; Industrial Emissions EN 8-; Industrial Immunity EN ; eas./ontrol/lab., Industrial Requirements EN --; Industrial Immunity -ick - Australian Radiocommunications Act compliant with AS/NZS ISPR, Industrial Emissions Includes offset, gain, nonlinearity and repeatability error terms. You use this category information for planning conductor routing as described in Allen-Bradley publication -., Industrial Automation iring and Grounding Guidelines. or the latest up-to-date information, see the Product ertification link at www.ab.com for Declarations of onformity, ertificates and other certification details. or notification of any additional release notes, refer to www.ab.com/manuals/. Publication 9-INB-EN-P - June

Publication 9-INB-EN-P - June PN 9899-9 Supersedes Publication 9-INA-EN-P - April opyright Rockwell Automation, Inc. All rights reserved. Printed in the.s.a.