DeltaV SISnet Repeater
|
|
|
- Tobias Mitchell
- 10 years ago
- Views:
Transcription
1 September 2013 Page 1 The DeltaV SIS platform is the world s smart SIS system to use the power of predictive intelligence for increasing the availability of the entire safety instrumented function. Fiber-optic repeater for redundant safetyrated communications Dedicated to safety no possibility of common-cause control and safety communications failures Introduction The DeltaV SIS TM system, part of Emerson s smart SIS, ushers in the next generation of Safety Instrumented Systems (SIS). This smart SIS approach uses the power of predictive field intelligence to increase the availability of the entire safety instrumented function. 50 ms update time anywhere on the DeltaV SISnet
2 September 2013 Page 2 Benefits Fiber-optic repeater for redundant safety-rated communications. The SISnet Repeater is used when safety-critical inter-trip signals are needed across a physically spread-out plant. Carrier Extender CTbles extend LocalBus power and signals between 8-wide carriers. Local peer bus extender cables extend the local peer bus (SISnet) between Logic Solvers on different carriers. 1-wide carriers with terminators terminate the local peer bus at the final carrier. Dedicated to safety. Some systems use the same networks for both control and safety. The DeltaV SIS system SISnet is dedicated to safety, carrying only safetyrated signals. It is therefore immune to any failure of the control network. 50 ms update time. All of the data broadcast on the SISnet is available to all of the other nodes within 50 ms. Combined with the speed of the logic solver, the 50 ms update time guarantees input-to-output times of less than 225 ms anywhere on the distributed SISnet. Spans 32 nodes. The SISnet spans 32 nodes in a redundant ring architecture. These nodes can be up to two km apart, so the entire ring can be up to 64 km around. The 50 ms update time is guaranteed regardless of network size. Product Description This section provides general information on DeltaV SIS hardware. Refer to the Installing Your DeltaV Digital Automation System manual for more information on DeltaV system equipment. DeltaV SIS Equipment A DeltaV automation system consists of carriers, one or more I/O subsystems, controllers, power supplies, workstations, and a control network. The DeltaV SIS system consists of: Logic Solvers (SLS 1508) and termination blocks (see separate product data sheet) SISnet Repeaters Carrier extender cables Local peer bus extender cables Right 1-wide carrier with termination SISnet Repeaters extend communication beyond the local Logic Solvers connected to one DeltaV controller and broadcast global messages to remote Logic Solvers through a fiber-optic ring. Global messages refer to messages that are intended for all Logic Solvers. The SISnet Repeater installs on a 2-wide carrier. There is a primary and secondary SISnet Repeater on each carrier. A redundant pair of SISnet Repeaters Communication Control Network: The DeltaV Control Network provides communication between the nodes in the DeltaV network. Refer to the Installing Your DeltaV Digital Automation System manual for complete information on the Control Network. LocalBus: The LocalBus provides communication between DeltaV controllers and Logic Solvers and between DeltaV controllers and SISnet Repeaters. Local Peer Bus (SISnet): Logic Solvers communicate with other Logic Solvers and with local SISnet Repeaters through the carriers over a 2-channel local peer bus. The same message is broadcast over both channels. The local peer bus must be terminated at both ends. The local peer bus is terminated at the left end through the 2-wide power/controller carrier and at the right end through a terminated 1-wide carrier. The SISnet Repeaters can be located anywhere on a local peer bus between the MD Controller(s) and the terminated 1-wide carrier. Remote Peer Ring: SISnet Repeaters hosted by one DeltaV controller communicate with SISnet Repeaters hosted by a different DeltaV controller over a fiber-optic remote peer ring. A local SISnet Repeater collects locally generated messages into a single message and sends it to the next SISnet Repeater in the ring. Upon receipt of a message, the receiving SISnet Repeater broadcasts it on its local peer bus (SISnet) and forwards the message to the next SISnet Repeater in the ring. A global message is forwarded around the ring once. The primary SISnet Repeaters form one fiber-optic ring and the secondary form a separate, independent ring. The fiber rings operate at 100 MB.
3 September 2013 Page 3 Extender cables: Carrier extender cables and local peer bus extender cables connecting a DeltaV controller and 8-wide carrier with standard DeltaV I/O and DeltaV SIS to a second 8-wide carrier (hosted by the same controller) are installed with Logic Solvers, SISnet Repeaters, and a terminated 1-wide carrier. Logic Solver messages are communicated to a remote DeltaV SIS (hosted by a separate controller) through fiber-optic cables.
4 September 2013 Page 4 SISnet Repeater Specifications Common Environmental Specifications for SISnet Repeater Category Storage temperature -40 to 85 C (-40 to 185 F) Operating temperature -40 to 70 C (-40 to 158 F) Relative humidity Airborne contaminants 5 to 95%, non-condensing ISA-S Airborne Contaminants Class G3 Conformal coating Protection rating IP 20, NEMA 12 Hazardous area/location Shock Vibration European EMC Directive per EN , Criterion A NAMUR NE21 EMC Requirements Low Voltage Directive IEC Factory Mutual, Non-Arcing Class 1, Div 2, Groups A, B, C, D, T4 hazardous locations ATEX 3 G EEx IIC-nA T4 EN50021:1999 CSA g ½-sine wave for 11 ms 1 mm peak-to-peak from 5 to 16 Hz; 0.5 g from 16 to 150 Hz SISnet Repeater Specifications Item Port Type Cables Type Output power Link budget Link distance (max) Topology Test port type Mounting ST Female Multimode 62.5 / 125 μm; ST type or Multimode 50 / 125 μm; ST type < -12 db Multimode 62.5 / 125 μm max attenuation 11 db Multimode 50 / 125 μm max attenuation 8 db 2 km one way TxD to RxD Physical ring: RxD connects to TxD of predecessor and TxD connects to RxD of successor For factory use only 2-wide SISnet Repeater carrier Left carrier position is secondary SISnet Repeater; right carrier position is primary SISnet Repeater
5 September 2013 Page 5 SISnet Repeater Power Specifications Item Input Connector type Wire type Wire gauge 24 V DC, 300 ma (max) 4-position screw terminal Solid or Stranded 12 AWG maximum SISnet Repeater Dimensions SISnet Repeater Weight, Heat Generation and Power Consumption Item SISnet Repeater Weight kg Heat Dissipation 8 W Power V DC Weight 0.20 kg 1-wide SISnet Terminator Assembly Heat N/A Power N/A
6 September 2013 Page 6 Ordering Information Redundant SIS Net Repeater Description (Two Repeater modules and a two-wide carrier) SISnet Terminator Assembly 8-Wide Carrier with Extend Cable Assembly (Cable Assembly consists of left & right extender cards, 2 coax cables for Logic Solver communications bus and one cable for carrier backplane communications) VS6002 VS6051 VE4050E1C2 Model Number Prerequisites DeltaV 8.3 software or later. To locate a sales office near you, visit our website at: Or call us at: Asia Pacific: Europe, Middle East: North America, Latin America: or For large power, water, and wastewater applications contact Power and Water Solutions at: Or call us at: Asia Pacific: Europe, Middle East, Africa: North America, Latin America: Emerson Process Management All rights reserved. For Emerson Process Management trademarks and service marks, go to: The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warrantees or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the design or specification of such products at any time without notice.
M-series MD Plus Controller
August 2013 Page 1 The DeltaV MD Plus Controller and the DeltaV I/O subsystem make rapid installation easy. Increases productivity Easy to use Has the flexibility to meet your needs Introduction The MD
S-series SQ Controller
DeltaV Distributed Control System Product Data Sheet December 2015 S-series SQ Controller Scalable controllers Quick assembly Easy-to-use Field proven architecture Designed for Electonic Marshalling Advanced
M-series FOUNDATION Fieldbus I/O
April 2013 Page 1 M-series FOUNDATION Fieldbus I/O Use DeltaV state-of-the-art FOUNDATION Fieldbus redundant I/O for your process control system Increases input/output Takes advantage of all smart device
S-series Mass Connection Solutions
DeltaV Distributed Control System Product Data Sheet March 2015 S-series Mass Connection Solutions Fast, easy and error-free cabinet wiring Modular design, improves reliability Lowers overall termination
S-series DC to DC Power Supply
January 2013 Page 1 The DeltaV S-series DC/DC system power supplies are modular, easy to install, and secure Easy to use Flexible and cost-effective Secure Simplified system power Introduction Power your
S-series DeviceNet Interface Card
January 2013 Page 1 The DeltaV provides the solution for interfacing to discrete actuators and sensors. Offers freedom to choose appropriate bus for application Supports standard device-level busses Reduces
Wireless I/O Card. Wireless I/O Card. Introduction. DeltaV Product Data Sheet
October 2014 Page 1 Redundant (WIOC) Fully redundant Wireless solution from to the Smart Wireless Field Link Optional simplex for smaller applications Seamless integration with DeltaV system and AMS Suite.
M-series Virtual I/O Module 2
DeltaV Distributed Control System Product Data Sheet M-series Virtual I/O Module 2 Non-intrusive DeltaV I/O simulation Powerful integration solution Easy to use Modular, flexible packaging The M-series
How To Protect Your Deltav Controllers From Cyber Attacks
February 2015 Page 1 DeltaV Controller Firewall The provides additional security protection from for your DeltaV controllers Provides an additional level of economical cyber-protection to your DeltaV controllers
DeltaV Control Network Hardware
DeltaV Distributed Control System Product Data Sheet October 2014 DeltaV Control Network Hardware The DeltaV Control Network is easy to install and maintain with the new DeltaV Smart Switches Easy to use
Wireless Field Data Backhaul
October 2014 Page 1 Smart Wireless Gateway 1552WU An Emerson Smart Solution integrates WirelessHART data from remote areas of your plant. Scalable Reduced cost Safer deployment Secure and reliable communications
NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module
DATASHEET NI 9423 8-Channel Sinking Digital Input Module 8-channel, 100 µs digital input 24 V logic, sinking digital input Compatible with NI CompactDAQ counters 250 Vrms, CAT II isolation 10-position
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Rosemount 333 HART Tri-Loop
Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure
1701/22 FieldMonitor Management Interface Module
1701/22 FieldMonitor Management Interface Module Bently Nevada Asset Condition Monitoring Description The 1701/22 FieldMonitor Management Interface Module (FMIM) is a highlyintegrated module that provides
S-series Electronic Marshalling
DeltaV Distributed Control System Product Data Sheet S-series Electronic Marshalling I/O anywhere you need it Single channel granularity Reduces installed cost of system Fully redundant architecture Field
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
1756 ControlLogix Chassis Specifications
Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,
How To Use The Deltav System With A Large Data File System
January 2013 Page 1 This document outlines the user-defined import/export capabilities in the DeltaV system. www.deltav.com January 2013 Page 2 Table of Contents Introduction -----------------------------------------------------------------------------------------------------
DeltaV S-series Traditional I/O
DeltaV Distributed Control System Product Data Sheet DeltaV S-series Traditional I/O Modular and flexible construction. Reduced installation time and expense. Easy online expansion. Field mounted capable
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
Plant Messenger Alert Reporting Service
January 2013 Page 1 Plant Messenger Alert Reporting Service Plant Messenger delivers DeltaV alarms and events anywhere in the world. Delivers DeltaV and DeltaV SIS alarms, events and device alerts to enterprise
3500/62 Process Variable Monitor
3500/62 Process Variable Monitor Description The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters (pressures, flows, temperatures, levels, etc.) that merit
DeltaV Network Time Synchronization
Whitepaper January 2013 Page 1 Network Time Synchronization Network Time Synchronization This document describes how system time is managed for Version 5.2 onward. The Symmetricom SyncServer S250 is the
Rosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
OPC Data Access Server Redundancy
January 2013 Page 1 Redundant OPC Data Access servers provide highly reliable data transfer. Reliable data transfer Hardware and module redundancy Automatic switchover Online upgradable Introduction The
Foxboro Evo Process Automation System
Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module
Plantwide Event Historian
March 2014 Page 1 The collects and stores alarm and event records from any OPC Alarms & Events server. Captures and displays event data for the entire plant Robust data collection mechanism Event viewer
XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment
XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment Part of the device networking family of networkenablement products, XPress-Pro SW series
HARTING mcon 1000 Introduction and features
Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)
DeltaV SIS for Burner Management Systems
January 2011 Page 1 DeltaV SIS for Burner Management Systems RESULTS Inhibit startup when unsafe conditions exist Protect against unsafe operating conditions, including improper fuel quantities Provide
Emerson Smart Firewall
DeltaV TM Distributed Control System Product Data Sheet Emerson Smart Firewall The Emerson Smart Firewall protects the DeltaV system with an easy to use perimeter defense solution. Purpose built for easy
Wireless Remote Video Monitoring
October 2014 Page 1 An Emerson Smart Solution brings visual information into your control room. Increase plant safety Comply with regulations Scalable Reduced cost Secure and reliable communications Full
DeltaV Event Chronicle
January 2013 Page 1 DeltaV Event Chronicle The stores process alarm and event information. Captures events electronically Provides complete process event record Easy event viewing and filtering Uses MS
1788 Linking Device Specifications
Technical Data 1788 Linking Device Specifications Catalog Numbers 1788-EN2DNROM, 1788-EN2DNR, 1788-EN2FFR, 1788-EN2PAR, 1788-CN2DN, 1788-CN2FFR, 1788-CN2PAR, 1788-FBJB4R, 1788-FBJB6 Topic Page 1788-EN2DNR
DeltaV Web Server. DeltaV Web Server. Introduction. DeltaV Product Data Sheet. Gives you a secure view of your process from your desktop PC
January 2013 Page 1 DeltaV Web Server Use the to view your process anywhere on the planet. Gives you a secure view of your process from your desktop PC Offers more information and scalable architecture
Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
ProfessionalPLUS Station Software Suite
January 2013 Page 1 All you need to configure, control, and diagnose your plant is available on the ProfessionalPLUS Station Global database, architected for flexibility and scalability Powerful, graphical
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
DeltaV Virtual Studio
June 2013 Page 1 DeltaV Virtual Studio Makes Virtualization Easy. DeltaV Virtualization Made Easy Reduced Costs and Increased Flexibility Fewer Computers and Control Hardware Extended System Life with
High Availability and Safety solutions for Critical Processes
High Availability and Safety solutions for Critical Processes An Introduction to AADvance Subrahmanya Bhat P Sr. Systems Engineer 09 & 10 th Sep 2014 PUBLIC INFORMATION Rev 5058-CO900E 2 Agenda Process
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
DeltaV Workstation Operating System Licensing Implications with Backup and Recovery
November 2013 Page 1 DeltaV Workstation Operating System Licensing Implications with Backup and Recovery This document details the Microsoft Windows Operating Systems licensing models used in the DeltaV
Hirschmann Switch-Tuning: The new Gigabit OpenRail.
irschmann Switch-Tuning: The new Gigabit OpenRail. 9-port Full-Gigabit ETERNET switch For upgrading slower networks ighest levels of flexibility thanks to the SFP Designed for use in industrial environments
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
3500/22M Transient Data Interface
3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery
OPC Mirror. OPC Mirror. Introduction. Product Data Sheet. Bi-directional data flow. Easy configuration. Fast data transfer. OPC Data Access compliant
January 2013 Page 1 Data transfer between OPC servers is easy with Bi-directional data flow Easy configuration Fast data transfer OPC Data Access compliant Runs anywhere Redundant operation Introduction
Wireless Remote Video Monitoring
February 2010 Page 1 An Emerson Smart Solution brings visual information into your control room. Increase Plant Safety Comply with Regulations Scalable Reduced Cost Secure and Reliable Communications Full
3500/25 Enhanced Keyphasor*Module
3500/25 Enhanced Keyphasor*Module Bently Nevada* Asset Condition Monitoring Description The 3500/25 Enhanced Keyphasor Module is a half-height, two-channel module used to provide Keyphasor signals to the
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide
31007950 7/2009 ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide 7/2009 31007950.02 www.schneider-electric.com NOTICE Read these instructions carefully, and look at the equipment to become
HARTING mcon 3000 Introduction and features
Introduction and features HARTING mcon 3000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features The fully managed es of the product family HARTING mcon
Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation
Stand Alone POTS Fiber Optic System P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit Description & Installation Printed in USA 09/11 TO466 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
DeltaV Virtual Studio
DeltaV Distributed Control System Product Data Sheet June 2015 DeltaV Virtual Studio DeltaV Virtual Studio Makes Virtualization Easy. DeltaV Virtualization Made Easy. Reduced Costs and Increased Flexibility.
L5354 ControlNet Communications Interface
L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
1756 ControlLogix Power Supplies Specifications
Technical Data 1756 ControlLogix Power Supplies Specifications Standard Power Supplies Catalog Numbers 1756-PA72, 1756-PA75, 1756-PB72, 1756-PB75, 1756-PC75, 1756-PH75 Standard Slim Power Supplies Catalog
Base Station. Base Station. Introduction. DeltaV Product Data Sheet. Adaptable work environment. Scalable to suit your needs. Dedicated functional use
September 2013 Page 1 Use the to build a custom DeltaV workstation to meet your needs. Adaptable work environment Scalable to suit your needs Dedicated functional use Introduction Are you looking for process
R&S SMZ Frequency Multiplier Specifications
Test & Measurement Data Sheet 02.00 R&S SMZ Frequency Multiplier Specifications CONTENTS Definitions... 3 Specifications... 4 RF performance...4 Frequency...4 Level...4 Spectral purity...4 Connectors...5
IntesisBox KNX - LON
IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,
ADACSNET USB Control Module
ADACSNET USB Control Module Installation Guide Termination Switch 2-Pin SensorNet Connection Features and Hookup The USB Control Module contains the following: - USB port: Connects to the host computer.
Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter
Industrial 10/100/BASE-T to 100/BASE-X SFP Media Converter Physical Port 1-port 10/100/BASE-T RJ45 with auto MDI / MDI-X function 1 SFP interface, 100/BASE-X dual mode (auto detection) Layer 2 Features
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
3500/40M Proximitor* Monitor
3500/40M Proximitor* Monitor Bently Nevada* Asset Condition Monitoring Description The 3500/40M Proximitor Monitor is a 4-channel monitor that accepts input from Bently Nevada proximity transducers, conditions
My first Hirschmann: The SPIDER family of switches.
My first Hirschmann: The SPIDER family of switches. Large selection of entry level switches Compact design Simple rail installation Industry standard 24 V supply voltage Plug & Play gets you up and running
MechoNet TM Network Interface (MNI) Specification Submittal
MechoNet TM Network Interface (MNI) Specification Submittal Models MechoNet Network Interface: MNI RJ (RJ45 Motor Ports): Stock No.: IMNI 0001 TP AS (US version) Stock No.: IMNI 0004 TP AS (UK version)
Technical Data Sheet. 3DLevelScanner
Changing the market from level to volume Technical Data Sheet APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common
Características. Starligh SA 9 de julio 1595 Córdoba Argentina - 0351-4809210 / 4119600
Balun Activo - BALUN_ACT Características Single Channel Active Video Transmitter Full-motion color video signal up to 3900ft(1200m) via UTP cat5e/6 NTSC, PAL & SECAM video format compatible Real-time transmission
NetScanner System. Toronto: 416 754 7008, Montreal: 514 695 5147, Toll Free:1888 754 7008, Email: [email protected]; www.a-tech.ca
Networking Solutions NetScanner System 9IFC/90DB/90DC FEATURES Ethernet Interface for NetScanner System Modules Provides Power and Hardware Trigger Interface 10/100 Base-T Auto-Negotiating Universal AC
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
Product overview. 2000 mm. 100 mm
Panel mounted electronic multi-circuit heat-tracing control, monitoring and power distribution system Product overview CABLE DUCT Card Rack Modules TERMINAL STRIP PLINTH MAIN SWITCH 800 mm USER INTERFACE
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Maintenance Station Software Suite
January 2013 Page 1 You can easily engineer and operate your process automation system from the Maintenance Station, Graphical view and annunciation of intelligent device alerts Fieldbus and HART Powerful
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown
Self-Regulating 920 Series Dual-point heat-tracing control system Power-Limiting Mineral Insulated 920*E4FWL*SIS302*SS3102 shown Product overview The DigiTrace 920 is a compact, full-featured, microprocessor-based,
iva Cable & Antenna Analyzer
iva Cable & Antenna Analyzer VSWR, Return Loss Measurement & Distance to Fault The iva Series Cable & Antenna Analyzer is an exciting new product from Kaelus that enables users to accurately measure VSWR/return
Hardware Manual RM CANview Ethernet
Hardware Manual RM CANview Ethernet Table of Contents 1 Legal Regulations...3 2 About the Device...4 3 Disposal...4 4 Important Information for Using CANview Ethernet...5 4.1 How to Open the Protection
How To Power A Power Supply Shelf With A Power Unit (Hp 2920)
Overview Models HP 640 Redundant/External Power Supply Shelf J9805A Key features Provides redundant or extenal power for HP 2920 Switch Series products Uses same modular power supplies as the HP 2920 Switches
Professional Station Software Suite
January 2013 Page 1 You can easily engineer and operate your process automation system from the Professional Station Powerful, graphical engineering capabilities Robust and secure plant operations Integrated
TrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
Cable Specifications. T3 Trunk Cabling APPENDIX
APPENDIX B This appendix contains details on the MGX 8230 cabling. It includes the following sections: T3 Trunk Cabling Frame Relay Cabling DC Power Cabling AC Power Cabling Control and Clock Cabling External
Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS
Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and
Mitel DECT Base Stations
Mitel DECT Base Stations On-site Mobility for Professionals The Mitel BS300 range of base stations offers a variety of coverage patterns to suit different situations. By choosing the right mix of base
HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 [email protected] www.valcontrols.
HARDWARE MANUAL Ixx24-A 1/20 Table of contents 1 General... 3 1.1 Safety instructions... 3 1.2 Environment... 3 1.3 Mounting and dimension... 3 2 Communication... 4 2.1 Control loop AI0 and Transmitter
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
3500/15 Power Supply Bently Nevada* Asset Condition Monitoring
3500/15 Power Supply Bently Nevada* Asset Condition Monitoring Description The 3500 Power Supplies are half-height modules and must be installed in the specially designed slots on the left side of the