Micro800 Programmable Controller Family. Bulletin 2080 Selection Guide
|
|
|
- Gyles Bradford
- 9 years ago
- Views:
Transcription
1 Micro800 Programmable Controller Family Bulletin 2080 Selection Guide
2 Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation sales office or online at describes some important differences between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. IMPORTANT Identifies information that is critical for successful application and understanding of the product. ATTENTION Identifies information about practices or circumstances that can lead to: personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence. SHOCK HAZARD Labels may be on or inside the equipment, such as a drive or motor, to alert people that dangerous voltage may be present. BURN HAZARD Labels may be on or inside the equipment, such as a drive or motor, to alert people that surfaces may reach dangerous temperatures. Allen-Bradley, Rockwell Automation, Micro800, Micro810, Micro820, Micro830, Micro850, Connected Components Workbench, FactoryTalk, PowerFlex, CompactBlock, and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.
3 Select a Micro800 Controller Micro800 controllers are designed for low-cost, standalone machines. These economical small-size PLCs are available in different form factors based on the number of I/O points embedded in the base, with a range of features intended to address different requirements. The Micro800 family shares programming environment, accessories and plug-ins that allow machine builders to personalize the controller for specific capabilities. Micro810 controllers function as a smart relay with high current relay outputs, but with the programming capabilities of a micro PLC. The Micro810 controllers come in a 12-point form factor. Micro820 controllers are specifically designed for smaller standalone machines and remote automation projects. It has embedded Ethernet and serial ports and a microsd slot for datalogging and recipe management. These controllers come as 20-point form factors that can accommodate up to two plug-in modules. It also supports the Micro800 Remote LCD (2080-REMLCD) module to allow easier configuration of such settings as IP address and functions as a simple IP65 text display. 1
4 2 Micro800 Programmable Controller Family Selection Guide Micro830 controllers are designed for standalone machine control applications. They have flexible communications and I/O capabilities with up to five plug-ins. They come as a 10-, 16-, 24-, or 48-point form factors. Micro850 expandable controllers are designed for applications that require more digital and analog I/O or higher performance analog I/O. They can support up to four expansion I/O. Micro850 controllers include additional communication connection options through an embedded 10/100 Base-T Ethernet port. Several Micro830 and Micro850 controllers support basic positioning through embedded pulse train outputs (PTO). These controllers also allow you to configure up to six high speed counters (HSC), and choose from nine HSC operation modes. HSC is supported on all Micro830 and Micro850 catalogs, except on 2080-LCxx-xxAWB. PTO is only supported on Micro830 and Micro850 catalog numbers that end in BB or VB. This selection guide serves to help you identify the right controller, plug-ins, expansion I/O, and accessories, based on your requirements. Choose a Micro800 Controller 1 2 Select a Micro810 3 controller (go to page 9) Select a Micro800 controller (go to page 3) Select a Micro820 controller (go to page Select a Micro830 controller (go to page 19) Select a Micro850 controller (go to page 29) Select Micro800 plug-ins and accessories (go to page 51) 4 Select Micro850 expansion I/O (go to page 41)
5 Micro800 Programmable Controller Family Selection Guide 3 Micro800 Controllers Comparison Features Attribute Micro810 Micro820 Micro830 Micro850 Communication ports, embedded 12-point 20-point 10-point 16-point 24-point 48-point 24-point 48-point USB 2.0 (with USB 10/100 Base T USB 2.0 (non-isolated) USB 2.0 (non-isolated) adapter) Ethernet port (RJ-45) RS232/RS485 non-isolated combo serial RS232/RS485 RS232/RS485 non-isolated combo serial non-isolated combo serial 10/100 Base T Ethernet port (RJ-45) Embedded digital I/O points (1) Base analog I/O channels Four 24V DC digital inputs are shared as 0 10V analog inputs (DC input models only) One 0 10V analog output Four 24V DC digital inputs can be configured as 0 10V analog inputs (DC input models only) and via plug-in modules Via plug-in modules Via plug-in modules and expansion I/O Number of plug-in modules Maximum digital I/O (2) Types of accessories or plug-ins supported LCD display with backup memory module USB adapter Micro800 Remote LCD (2080-REMLCD) All-plug-in modules except 2080-MEMBAK- RTC (see page 51) All plug-in modules (see page 51) Expansion I/O supported All expansion I/O modules (see page 41) Power supply Embedded 120/240V AC and 12/24V DC options Basic instruction speed 2.5 μs per basic instruction Base unit has embedded 24V DC power supply, optional external 120/240V AC power supply available 0.30 μs per basic instruction Minimum scan/cycle <0.25 ms <4 ms <0.25 ms time (3) Software Connected Components Workbench (1) See Number and Types of Inputs/Outputs for Micro810, Micro820, Micro830, and Micro850 Catalogs on page 6. (2) For Micro820 and Micro830 controllers, the number of maximum digital I/O assumes 8-point digital I/O plug-ins (for example, 2080-IQ4OB4) are used on all available plug-in slots. For Micro850 controllers, the maximum number of digital I/O supported between the base, plug-ins, and expansion I/O is 132. (3) Including reading and writing I/O, program execution, and communications overhead.
6 4 Micro800 Programmable Controller Family Selection Guide Micro800 Controller Programming Comparison (with Connected Components Workbench) Attribute Micro point Micro point Micro830 10/16-point Micro point Micro point Micro point Program steps (1) 2 K 10 K 4 K 10 K 10 K 10 K 10 K Data bytes 2 KB 20 KB 8 KB 20 KB 20 KB 20 KB 20 KB Micro point IEC languages Ladder diagram, function block diagram, structured text User defined function blocks Yes Floating point 32-bit and 64-bit PID Loop Control Yes (number limited only by memory) Embedded serial port protocols None Modbus RTU Master/Slave, ASCII/Binary, CIP Serial (1) Estimated Program and Data size are typical program steps and variables are created dynamically. 1 Program Step = 12 data bytes. The number of bytes per instruction can vary greatly from program to program and from programming language to programming language. Micro800 Communication Options Controller USB programming port Embedded Serial Port, Serial Port Plug-In Embedded Ethernet CIP Serial Modbus RTU ASCII/Binary EtherNet/IP Modbus TCP Micro810 Yes (with adapter) No Micro820 Yes (with 2080-REMLCD) Yes Master/Slave Yes Yes Yes Micro830 Yes Yes Master/Slave Yes No No Micro850 Yes Yes Master/Slave Yes Yes Yes Micro800 Controllers Analog I/O and TC/RTD Comparison Attribute Micro810 Micro820 Micro800 (with plug-ins) Performance level LOW LOW MEDIUM HIGH Isolation to controller None None None Yes (increased noise immunity) Resolution and Nominal Accuracy Input update rate and filtering Analog Input: 10-bit, 5% (2% with calibration) Update rate only dependent on program scan, limited filtering Analog I/O: 12-bit, 5% (2% with calibration) Update rate only dependent on program scan, limited filtering Analog I/O: 12-bit, 1% TC/RTD: ±1 C CJC for TC: ±1.2 C 200 ms/ch, 50/60 Hz filtering Micro850 (with expansion I/O) Analog Input: 14-bit input, ±0.1% Analog Output: 12-bit output, 0.133%, current, 0.425% voltage TC: ±0.5 ±3.0 C RTD: ±0.2 ±0.6 C 8 ms all channels with or without 50/60 Hz filtering Recommended maximum 10 m 100 m shielded cable length (1) (1) These numbers are guidelines only. Maximum cable length is dependent on the application and other factors such as cable type, installation, required accuracy, sensor, and so on.
7 Micro800 Programmable Controller Family Selection Guide 5 Micro800 Power Requirements (1) Controller/Module Micro point (with or without LCD) Micro point (2) (without plug-ins, max) Micro830 and Micro850 (without plug-in/expansion I/O) 10/16-point 24-point 48-point Plug-in modules, each Expansion I/O (system bus power consumption) Power Requirement 3 W (5V A for AC module) 5.62 W 5W 8W 11 W 1.44 W 2085-IQ IQ32T 2085-IA IM OA OB OV OW OW IF IF OF IRT4 (1) When setting up a Micro800 system, verify that total power consumption of the controller, plug-in and expansion I/O does not exceed the output power capacity of the power supply used. See External Power Supply (2080-PS VAC) on page 59 for power supply specifications. (2) Micro820 controllers require a maximum of 8.5 W with plug-ins W 0.95 W 0.75 W 0.75 W 0.90 W 1.00 W 1.00 W 1.80 W 3.20 W 1.70 W 1.75 W 3.70 W 2.00 W
8 6 Micro800 Programmable Controller Family Selection Guide Number and Types of Inputs/Outputs Number and Types of Inputs/Outputs for Micro810, Micro820, Micro830, and Micro850 Catalogs Controller Family Catalogs Inputs Outputs Analog Out 120V 24V DC/ 12V Relay 24V DC 0 10V DC AC V AC DC Source 120 / 240V AC 24V DC Sink Analog In 0 10V (shared with DC In) PTO/PWM Support (1) Micro LC10-12QWB LC10-12AWA LC10-12QBB LC10-12DWD Micro LC20-20QBB (PWM) 2080-LC20-20QWB LC20-20AWB LC20-20QBBR (PWM) 2080-LC20-20QWBR LC20-20AWBR Micro LC30-10QWB LC30-10QVB (PTO/PWM) LC30-16AWB LC30-16QWB LC30-16QVB (PTO/PWM) LC30-24QWB LC30-24QVB (PTO/PWM) LC30-24QBB (PTO/PWM) LC30-48AWB LC30-48QWB LC30-48QVB (PTO/PWM) LC30-48QBB (PTO/PWM) 6 Micro LC50-24AWB LC50-24QBB (PTO/PWM) LC50-24QVB (PTO/PWM) LC50-24QWB LC50-48AWB LC50-48QWB LC50-48QBB (PTO/PWM) LC50-48QVB (PTO/PWM) 6 (1) For Micro830 and Micro850, you need firmware revision or later to use PWM output. (2) Maximum number of embedded HSC supported. Embedded HSC Support (2)
9 Micro800 Programmable Controller Family Selection Guide 7 Micro800 Catalog Number Details LC Q V B Bulletin Number Base Unit LC10 = Micro810 LC20 = Micro820 LC30 = Micro830 LC50 = Micro850 Number of I/O 10, 12, 16, 20, 24, 48 Power Supply A (1) = 120/240V AC B = 24V DC D (1) = 12V DC Output Type B = 24V DC Source V = 24V DC Sink W = Relay Input Type A = 110V AC or 110/220V AC Q = 24V AC/DC D (1) = 12V DC (1) Available for Micro810 only. Connected Components Workbench Software Connected Components Workbench is the programming and configuration software environment for the Micro800 controllers and our Connected Components products offering. It simplifies setup and usage, enabling applications ranging from simple Smart Relay up to Standalone Machine control. Visit the website for the most up-to-date product information, downloads and tools: mponents-workbench-software. Standard Edition Attribute Delivery Packaging options Features Basic Download Connected Components Workbench Standard Edition for FREE at Available on DVD, orderable from Connected Components Workbench web page at LD, FBD and ST editors user-defined function blocks No activation needed Optional registration during installation (for product updates and notices)
10 8 Micro800 Programmable Controller Family Selection Guide Developer Edition The Developer Edition offers the following additional programming features: User-defined Structures You can combine different data types to create structures and then assign them to user-defined variables. Structures are useful when you want a single variable to hold several related pieces of information. For example, you might want to define a structure to keep temperature ranges and alarm levels for a device rather than creating multiple variables. Spy Lists You can define spy lists to monitor changes in variables and function block instances in Connected Components Workbench programs. The Developer Edition installs the following additional software: FactoryTalk Activation Manager v (CPR 9 SR 6) FactoryTalk Diagnostics v (CPR 9 SR 6) Microsoft Help Viewer 1.1 Note: The Developer Edition requires an activation key. See the FactoryTalk Activation help for additional information on activating Rockwell Automation software products.
11 Select a Micro810 Controller As the smallest of the Micro800 family, the Micro810 controller is available in a 12-point version, with two 8 A and two 4 A outputs that eliminate the need for external relays. The Micro810 features embedded smart relay function blocks that can be configured from a 1.5 LCD and keypad. The function blocks include Delay OFF/ON Timer, Time of Day, Time of Week and Time of Year for applications requiring a programmable timer and lighting control. Programming can also be done through a program download via USB programming port, using Connected Components Workbench Software. To help you select a Micro810 controller, consult the specifications for each catalog in the next section. Number and Types of Inputs/Outputs Catalog Number Power Inputs Outputs Analog In 0 10V (shared with DC In) 120V AC 240V AC 12 24V DC /V AC Relay 24 V DC SRC 2080-LC10-12QWB 24V DC LC10-12AWA V AC LC10-12QBB 12 24V DC LC10-12DWD 12V DC
12 10 Micro800 Programmable Controller Family Selection Guide Specifications (1) Attribute 2080-LC10-12AWA 2080-LC10-12QWB 2080-LC10-12DWD 2080-LC10-12QBB Number of I/O Dimensions HxWxD 8 Input (4 digital, 4 analog/digital, configurable) 4 Output 91 x 75 x 59 mm (3.58 x 2.95 x 2.32 in.) Supply voltage range V DC V DC 10.8V 13.2V DC 11.4V..26.4V DC Supply frequency range (AC supply) Hz Voltage range V AC, 50/60 Hz 24V DC Class 2 12V DC Class 2 12/24V DC Class 2 Power consumption 5V A 3 W I/O rating Input: V AC Input: 24V DC, 8 ma Input: 12V DC, 8 ma Input: 24V DC, 8 ma Operating temperature Shipping weight, approx. Wire size Wiring category Wiring torque Wire type Fuse, type Enclosure type rating North American temp code Insulation stripping length Isolation voltage Output: Relay 00 & 01: 8 240V AC, B300, R300, General Use Relay 02 & 03: 4 240V AC, C300, R150, General Use 0 55 C ( F) kg (0.448 lb) mm² ( AWG) solid copper wire or mm² ( AWG) stranded copper wire 90 C (194 F ) insulation max. 2 on signal ports 2 on power ports Nm (8 lb-in.) use Copper Conductors only Rated 250V 3.15 A-RADIAL Meets IP20 T5 7 mm (0.28 in.) 250V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs. Type tested for 60 s 3250V DC, I/O to Aux and Network, Inputs to Outputs 250V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs Type tested for V DC, Inputs to Aux and Network, 3250V DC Outputs to Aux and Network, Inputs to Outputs Output: 24V DC 1A, 25 C, 24V DC 0.5A 55 C 50V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs Type tested for V DC, I/O to Aux and Network, Inputs to Outputs AC input filter setting 16 ms for all embedded inputs (In Connected Components Workbench, go to the Embedded I/O configuration window to re-configure the filter setting for each input group) (1) See the Micro810 User Manual, publication 2080-UM001, for more Micro810 controller specifications.
13 Micro800 Programmable Controller Family Selection Guide 11 Environmental Attribute Temperature, operating Temperature, surrounding air, max Temperature, storage Relative humidity Vibration Shock, operating Shock, nonoperating Value IEC (Test Ad, Operating Cold), IEC (Test Bd, Operating Dry Heat), IEC (Test Nb, Operating Thermal Shock): 0 55 C ( F) 55 C (131 F) IEC (Test Ab, Unpackaged Non-operating Cold), IEC (Test Bb, Unpackaged Non-operating Dry Heat), IEC (Test Na, Unpackaged Non-operating Thermal Shock): C ( F) IEC (Test Db, Unpackaged Damp Heat): % non-condensing IEC (Test Fc, Operating): Hz Emissions CISPR 11 Group 1, Class A IEC (Test Ea, Unpackaged Shock): 30 g IEC (Test Ea, Unpackaged Shock): 30 g (DIN Rail Mounted) 30 g (Panel Mounted) ESD immunity IEC : 4 kv contact discharges 8 kv air discharges Radiated RF immunity IEC : 10V/m with 1 khz sine-wave 80% AM from MHz 10V/m with 200 Hz 50% Pulse 100% 900 MHz 10V/m with 200 Hz 50% Pulse 100% 1890 MHz 3V/m with 1 khz sine-wave 80% AM from MHz EFT/B immunity IEC : ±2 5 khz on power ports ±2 5 khz on signal ports Surge transient immunity IEC : ±1 kv line-line(dm) and ±2 kv line-earth(cm) on power ports ±1 kv line-line(dm) and ±2 kv line-earth(cm) on signal ports ±2 kv line-earth(cm) on shielded ports Conducted RF immunity IEC : 10V rms with 1 khz sine-wave 80% AM from 150 khz 80 MHz Voltage variation IEC : 60% dip for 5 and 50 periods on AC supply ports 30% dip for 0.5 period at 0 and 180 on AC supply ports 100% dip for 0.5 period at 0 and 180 on AC supply ports ±10% fluctuations for 15 min on AC supply ports > 95% interruptions for 250 periods on AC supply ports
14 12 Micro800 Programmable Controller Family Selection Guide Certifications Certification (when product is marked) (1) c-ul-us Value UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E CE C-Tick UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E European Union 2004/108/EC EMC Directive, compliant with: EN ; Industrial Immunity EN ; Industrial Emissions EN ; Programmable Controllers (Clause 8, Zone A & B) EN ; Programmable Controllers (Clause 11) Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions (1) See the Product Certification link at for Declaration of Conformity, Certificates, and other certification details. For relay life chart, see the Specifications section of the Micro810 User Manual, publication 2080-UM001.
15 Select a Micro820 Controller As one of the smaller controllers in the Micro800 family, the Micro820 controller comes as a 20-point form factor, with six catalogs available for selection. The Micro820 controller is designed for smaller standalone machines and remote automation projects. It has the following features: Two plug-in module slots microsd card slot for project backup and restore, datalogging and recipe Embedded 10/100 Base-t Ethernet port(rj-45) Support for Remote LCD module (2080-REMLCD) for configuration Embedded non-isolated RS232/RS485 combo serial port Modbus RTU protocol (serial port) Modbus TCP support EtherNet/IP support CIP Serial support To help you select a Micro820 controller, consult the specifications for each catalog in the next section. 13
16 14 Micro800 Programmable Controller Family Selection Guide Number and Types of Inputs/Outputs for Micro820 Controllers Controller Family Catalogs Inputs Outputs Analog Out 120V AC 120 /240V 24V DC Relay 24V DC 24V DC 0 10V DC AC Source Sink Analog In 0 10V (shared with DC In) Micro LC20-20QBB LC20-20QWB LC20-20AWB LC20-20QBBR LC20-20QWBR LC20-20AWBR PWM Support Specifications General Specifications Attribute 2080-LC20-20AWB(R) 2080-LC20-20QBB(R) 2080-LC20-20QWB(R) Number of I/O 12 inputs, 8 outputs Dimension, HxWxD 90 x 104 x 75 mm (3.54 x 4.09 x 2.95 in.) Shipping weight, approx kg (0.83 lb) Wire size For fixed terminal blocks: Min Max Solid 0.14 mm 2 (26 AWG) 2.5 mm 2 (14 AWG) 90 C (194 F) insulation Stranded 0.14 mm 2 (26 AWG) 1.5 mm 2 (16 AWG) max For removable terminal blocks: Min For RS232/RS485 serial port: Max Solid and Stranded 0.2 mm 2 (24 AWG) 2.5 mm 2 (14 AWG) 90 C (194 F) insulation max Min Max Solid 0.14 mm 2 (26 AWG) 1.5 mm 2 (16 AWG) 90 C Stranded 0.14 mm 2 (26 AWG) 1.0 mm 2 (18 AWG) (194 F) insulation max Wiring category (1) Wire type 2 on signal ports 2 on power ports 2 on communication ports Use copper conductors or shielded cables
17 Micro800 Programmable Controller Family Selection Guide 15 General Specifications Attribute 2080-LC20-20AWB(R) 2080-LC20-20QBB(R) 2080-LC20-20QWB(R) Terminal screw torque Input circuit type For removable and fixed terminal blocks: Nm ( lb-in.) using a 0.6 x 3.5 mm flat-blade screwdriver. Note: Use a handheld screwdriver to hold down the screws at the side. For RS232/RS485 serial port: Nm ( lb-in.) using 0.4 x 2.5 x 80 mm 2-component grip with non-slip grip screwdriver. 24V DC sink/source (standard) for 2080-LC20-20QWB(R), 2080-LC20-20QBB(R) 120V AC for 2080-LC20-20AWB(R) for Inputs 4 11 only Output circuit type Relay 24V DC source (standard and high-speed) Power input 24V DC Power consumption 5.62 W (without plug-ins, max) 8.5 W (with plug-ins, max) Power dissipation 6 W Power supply voltage range V DC, Class 2 Auxiliary power supply output for 10V thermistor I/O rating Isolation voltage Input: 120V AC 16 ma Output: 2 A, 240 V AC 2A, 24V DC 250V (continuous), Reinforced Insulation Type, Output to Aux and Network, Inputs to Outputs. 150V (continuous), Reinforced Insulation Type, Input to Aux and Network. Type tested for V DC Output to Aux and Network, Inputs to Outputs. Type tested for V DC Input to Aux and Network. Input: 24V DC, 8.8 ma Output: 24V DC, 1 A per point (Surrounding air temperature 30 C) 24 V DC, 0.3 A per point (Surrounding air temperature 65 C) 50V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs. Type tested for V DC, I/O to Aux and Network, Inputs to Outputs. Relay Input: 24V DC, 8.8 ma Output: 2 A, 240 V AC, 2A, 24V DC 250V (continuous), Reinforced Insulation Type, Output to Aux and Network, Inputs to Outputs. 50V (continuous), Reinforced Insulation Type, Input to Aux and Network. Type tested for V DC, Inputs to Aux and Network, 3250 V DC Outputs to Aux and Network, Inputs to Outputs. Pilot duty rating C300, R150 C300, R150 Insulation stripping length 7 mm for the removable and fixed terminal blocks 5 mm for the RS232/RS485 serial port Enclosure type rating Meets IP20 North American temp code T4 (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication
18 16 Micro800 Programmable Controller Family Selection Guide Environmental Specifications Attribute Temperature, operating Temperature, surrounding air, max Temperature, nonoperating Relative humidity Vibration Shock, operating Shock, non-operating Value IEC (Test Ad, Operating Cold), IEC (Test Bd, Operating Dry Heat), IEC (Test Nb, Operating Thermal Shock): C ( F) 65 C (149 F) IEC (Test Ab, Unpackaged Nonoperating Cold), IEC (Test Bb, Unpackaged Nonoperating Dry Heat), IEC (Test Na, Unpackaged Nonoperating Thermal Shock): C ( F) IEC (Test Db, Unpackaged Damp Heat): 5 95% non-condensing IEC (Test Fc, Operating): Hz Emissions CISPR 11 Group 1, Class A IEC (Test Ea, Unpackaged Shock): 25 g IEC (Test Ea, Unpackaged Shock): DIN mount: 25 g PANEL mount: 45 g ESD immunity IEC : 6 kv contact discharges 8 kv air discharges Radiated RF immunity IEC : 10V/m with 1 khz sine-wave 80% AM from MHz 10V/m with 200 Hz 50% Pulse 100% 900 MHz 10V/m with 200 Hz 50% Pulse 100% 1890 MHz 10V/m with 1 khz sine-wave 80% AM from MHz EFT/B immunity IEC : ±2 5 khz on power ports ±2 5 khz on signal ports ±1 5 khz on communication ports Surge transient immunity IEC : ±1 kv line-line(dm) and ±2 kv line-earth(cm) on power ports ±1 kv line-line(dm) and ±2 kv line-earth(cm) on signal ports ±1 kv line-earth(cm) on communication ports Conducted RF immunity IEC : 10V rms with 1 khz sine-wave 80% AM from 150 khz 80 MHz
19 Micro800 Programmable Controller Family Selection Guide 17 Certifications Certification (when product is marked) (1) c-ul-us CE Value UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E European Union 2004/108/EC EMC Directive, compliant with: EN ; Meas./Control/Lab., Industrial Requirements EN ; Industrial Immunity EN ; Industrial Emissions EN ; Programmable Controllers (Clause 8, Zone A & B) C-Tick EtherNet/IP KC European Union 2006/95/EC LVD, compliant with: EN ; Programmable Controllers (Clause 11) Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions ODVA conformance tested to EtherNet/IP specifications Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3 (1) See the Product Certification link at for Declaration of Conformity, Certificates, and other certification details. For more information, see the Micro820 Programmable Controllers User Manual, publication 2080-UM005.
20 18 Micro800 Programmable Controller Family Selection Guide Notes:
21 Select a Micro830 Controller The Micro830 controller allows integration of as many as five plug-in modules. The plug-in modules enable machine builders to personalize the controllers to increase functionality. Most models offer removable terminal blocks and simplified communication via serial port. The controllers include: up to six embedded High-Speed Counter inputs (HSC) (1) 100 khz speed HSC available on 24V DC models up to three embedded Pulse Train Outputs (PTO) for basic positioning (2) High speed input interrupts Modbus RTU protocol (serial port) CIP Serial to allow tighter integration with PanelView Component Embedded USB programming and serial port (RS232/RS485) Plug-in slots to customize according to needs To help you select a Micro830 controller, check out the specifications for each catalog in the next section. (1) Embedded HSC is supported on all Micro830 catalog numbers, except on 2080-LC30-xxAWB. (2) PTO is supported on Micro830 catalog numbers ending in BB or VB only. 19
22 20 Micro800 Programmable Controller Selection Guide Inputs and Outputs Micro830 Controllers Number and Type of Inputs/Outputs Catalog Number Inputs Outputs PTO/PWM Support 120V AC 24V DC/V AC Relay 24V Sink 24V Source 2080-LC30-10QWB LC30-10QVB LC30-16AWB LC30-16QWB LC30-16QVB LC30-24QBB LC30-24QVB LC30-24QWB LC30-48AWB LC30-48QBB LC30-48QVB LC30-48QWB (1) Maximum number of HSC supported. HSC Support (1) Micro830 Controllers General Features Attribute 10-point 2080-LC30-10QWB 2080-LC30-10QVB 16-point 2080-LC30-16AWB 2080-LC30-16QWB 2080-LC30-16QVB 24-point 2080-LC30-24QWB 2080-LC30-24QVB 2080-LC30-24QBB 48-point 2080-LC30-48AWB 2080-LC30-48QWB 2080-LC30-48QVB 2080-LC30-48QBB Number of I/O 10 (6 inputs, 4 outputs) 16 (10 inputs, 6 outputs) 24 (14 inputs, 10 outputs) 48 (28 inputs, 20 outputs) Dimensions, HxWxD 90 x 100 x 80 mm (3.54 x 3.94 x 3.15 in.) 90 x 100 x 80 mm (3.54 x 3.94 x 3.15 in.) 90 x 150 x 80 mm (3.54 x 5.91 x 3.15 in.) 90 x 230 x 80 mm (3.54 x 9.06 x 3.15 in.) Shipping weight, approx kg (0.666 lb) kg (0.666 lb) kg (0.933 lb) kg (1.60 lb) Operating temperature C ( F) Wire size mm 2 (26 14 AWG) solid copper wire or mm 2 (26 16 AWG) stranded copper wire 90 C (194 F) insulation max mm 2 (24 14 AWG) solid copper wire or mm 2 (24 14 AWG) stranded copper wire 90 C (194 F) insulation max Wiring category (1) 2 on signal ports; 2 on power ports Wire type Use copper conductors only Terminal screw torque, max 0.6 Nm (4.4 lb-in.) (using a 2.5 mm (0.10 in.) flat-blade screwdriver) Power consumption 7.88 W W 18.2 W Power supply voltage range V DC Class 2 Insulation stripping length 7 mm (0.28 in.) Enclosure type rating Meets IP20 North American temp code T4 (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication
23 Micro800 Programmable Controller Selection Guide 21 Micro830 Controllers 10- and 16-Point Controllers General Specifications 10-point controllers Attribute 2080-LC30-10QWB 2080-LC30-10QVB Input circuit type 12/24V sink/source (standard) 24V sink/source (high-speed) Output circuit type Relay 24V DC sink transistor standard and high-speed Event input interrupt support I/O rating Isolation voltage Yes Input 24V DC, 8.8 ma Output 2 A, 240V AC, general use 250V (continuous), Reinforced Insulation Type, Outputs to Aux and Network, Inputs to Outputs Type tested for V DC, Inputs to Aux and Network, 3250V DC Outputs to Aux and Network, Inputs to Outputs Pilot duty rating C300, R150 Input 24V DC, 8.8 ma Output 2 A, 24V DC, 1 A per point (Surrounding air temperature 30 C) 24V DC, 0.3 A per point (Surrounding air temperature 65 C) 50V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs Type tested for V DC, I/O to Aux and Network, Inputs to Outputs General Specifications 16-point controllers Attribute 2080-LC30-16AWB 2080-LC30-16QWB 2080-LC30-16QVB Input circuit type 120V AC 12/24V sink/source (standard) 24V sink/source (high-speed) Output circuit type Relay 12/24V DC sink transistor standard and high-speed Event input interrupt support Yes
24 22 Micro800 Programmable Controller Selection Guide General Specifications 16-point controllers Attribute 2080-LC30-16AWB 2080-LC30-16QWB 2080-LC30-16QVB I/O rating Isolation voltage Input 120V AC, 16 ma Output 2 A, 240V AC, general use Input 24V DC, 8.8 ma Output 2 A, 240V AC, general use 250V (continuous), Reinforced Insulation Type, Outputs to Aux and Network, Inputs to Outputs 2080-LC30-16AWB: Type tested for V DC I/O to Aux and Network, Inputs to Outputs 2080-LC30-16QWB: Type tested for V DC, Inputs to Aux and Network, 3250V DC Outputs to Aux and Network, Inputs to Outputs Pilot duty rating C300, R150 Input 24V DC, 8.8 ma Output 24V DC, 1 A per point (Surrounding air temperature 30 C) 24 V DC, 0.3 A per point (Surrounding air temperature 65 C) 50V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs Type tested for 720V DC, I/O to Aux and Network, Inputs to Outputs Environmental Specifications Attribute Temperature, operating Temperature, surrounding air, max Temperature, non-operating Relative humidity Vibration Shock, operating Shock, non-operating Value IEC (Test Ad, Operating Cold), IEC (Test Bd, Operating Dry Heat), IEC (Test Nb, Operating Thermal Shock): C ( F) 65 C (149 F) IEC (Test Ab, Unpackaged Nonoperating Cold), IEC (Test Bb, Unpackaged Nonoperating Dry Heat), IEC (Test Na, Unpackaged Nonoperating Thermal Shock): C ( F) IEC (Test Db, Unpackaged Damp Heat): 5 95% non-condensing IEC (Test Fc, Operating): Hz Emissions CISPR 11 Group 1, Class A IEC (Test Ea, Unpackaged Shock): 25 g IEC (Test Ea, Unpackaged Shock): DIN mount: 25 g PANEL mount: 45 g ESD immunity IEC : 6 kv contact discharges 8 kv air discharges Radiated RF immunity IEC : 10V/m with 1 khz sine-wave 80% AM from MHz 10V/m with 200 Hz 50% Pulse 100% 900 MHz 10V/m with 200 Hz 50% Pulse 100% 1890 MHz 10V/m with 1 khz sine-wave 80% AM from MHz EFT/B immunity IEC : ±2 kv at 5 khz on power ports ±2 kv at 5 khz on signal ports Surge transient immunity IEC : ±1 kv line-line(dm) and ±2 kv line-earth(cm) on power ports ±1 kv line-line(dm) and ±2 kv line-earth(cm) on signal ports
25 Micro800 Programmable Controller Selection Guide 23 Environmental Specifications Attribute Value Conducted RF immunity IEC : 10V rms with 1 khz sine-wave 80% AM from 150 khz 80 MHz Certifications Certification (when product is marked) (1) c-ul-us CE Value UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E European Union 2004/108/EC EMC Directive, compliant with: EN ; Meas./Control/Lab., Industrial Requirements EN ; Industrial Immunity EN ; Industrial Emissions EN ; Programmable Controllers (Clause 8, Zone A & B) C-Tick European Union 2006/95/EC LVD, compliant with: EN ; Programmable Controllers (Clause 11) Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions (1) See the Product Certification link at for Declaration of Conformity, Certificates, and other certification details.
26 24 Micro800 Programmable Controller Selection Guide Micro Point Controllers General Specifications 24-point controllers Attribute 2080-LC30-24QWB 2080-LC30-24QVB 2080-LC30-24QBB Input circuit type 24V DC sink/source standard and high-speed Output circuit type Relay 24V DC sink standard and high-speed Event input interrupt support I/O rating Isolation voltage Yes Input 24V DC, 8.8 ma Output 2 A, 240 V AC, general use 250V (continuous), Reinforced Insulation Type, Outputs to Aux and Network, Inputs to Outputs Type tested for V DC, Inputs to Aux and Network, 3250V DC Outputs to Aux and Network, Inputs to Outputs Pilot duty rating C300, R150 (2080-LC30-24QWB only) 24V DC source standard and high-speed Input 24V DC, 8.8 ma Output 24V DC, Class 2, 1 A per point (Surrounding air temperature 30 C) 24V DC, Class 2, 0.3 A per point (Surrounding air temperature 65 C) 50V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs Type tested for V DC, I/O to Aux and Network, Inputs to Outputs Environmental Specifications Attribute Temperature, operating Temperature, surrounding air, max Temperature, non-operating Relative humidity Value IEC (Test Ad, Operating Cold), IEC (Test Bd, Operating Dry Heat), IEC (Test Nb, Operating Thermal Shock): C ( F) 65 C (149 F) IEC (Test Ab, Unpackaged Nonoperating Cold), IEC (Test Bb, Unpackaged Nonoperating Dry Heat), IEC (Test Na, Unpackaged Nonoperating Thermal Shock): C ( F) IEC (Test Db, Unpackaged Damp Heat): 5 95% non-condensing
27 Micro800 Programmable Controller Selection Guide 25 Environmental Specifications Attribute Vibration Shock, operating Shock, non-operating IEC (Test Fc, Operating): Hz Emissions CISPR 11 Group 1, Class A IEC (Test Ea, Unpackaged Shock): 25 g IEC (Test Ea, Unpackaged Shock): DIN mount: 25 g PANEL mount: 35 g ESD immunity IEC : 6 kv contact discharges 8 kv air discharges Radiated RF immunity IEC : 10V/m with 1 khz sine-wave 80% AM from MHz 10V/m with 200 Hz 50% Pulse 100% 900 MHz 10V/m with 200 Hz 50% Pulse 100% 1890 MHz 10V/m with 1 khz sine-wave 80% AM from MHz EFT/B immunity IEC : ±2 kv at 5 khz on power ports ±2 kv at 5 khz on signal ports Surge transient immunity IEC : ±1 kv line-line(dm) and ±2 kv line-earth(cm) on power ports ±1 kv line-line(dm) and ±2 kv line-earth(cm) on signal ports Conducted RF immunity IEC : 10V rms with 1 khz sine-wave 80% AM from 150 khz 80 MHz Certifications Value Certification (when product is marked) (1) c-ul-us CE Value UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E European Union 2004/108/EC EMC Directive, compliant with: EN ; Meas./Control/Lab., Industrial Requirements EN ; Industrial Immunity EN ; Industrial Emissions EN ; Programmable Controllers (Clause 8, Zone A & B) European Union 2006/95/EC LVD, compliant with: EN ; Programmable Controllers (Clause 11) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions (1) See the Product Certification link at for Declaration of Conformity, Certificates, and other certification details.
28 26 Micro800 Programmable Controller Selection Guide Micro Point Controllers General Specifications 48-point controllers Attribute 2080-LC30-48AWB 2080-LC30-48QWB 2080-LC30-48QVB 2080-LC30-48QBB Input circuit type 120V AC 24V DC sink/source standard and high-speed Output circuit type Relay 24V DC sink standard and high-speed Event input interrupt support I/O rating Yes, inputs 0 15 only Input 120V AC, 16 ma Output 2 A, 240V AC, general use Input 24V DC, 8.8 ma Output 2 A, 240V AC, general use Pilot duty rating C300, R150 Isolation voltage 250V (continuous), Reinforced Insulation Type, Outputs to Aux and Network, Inputs to Outputs Type tested for V DC I/O to Aux and Network, Inputs to Outputs 250V (continuous), Reinforced Insulation Type, Outputs to Aux and Network, Inputs to Outputs Type tested for V DC, Inputs to Aux and Network, 3250V DC Outputs to Aux and Network, Inputs to Outputs 24V DC source standard and high-speed Input 24V DC, 8.8 ma Output 24V DC, 1 A per point (Surrounding air temperature 30 C) 24 V DC, 0.3 A per point (Surrounding air temperature 65 C) 50V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs Type tested for V DC, I/O to Aux and Network, Inputs to Outputs
29 Micro800 Programmable Controller Selection Guide 27 Environmental Specifications Attribute Temperature, operating Temperature, surrounding air, max Temperature, non-operating Relative humidity Vibration Shock, operating Shock, non-operating Value IEC (Test Ad, Operating Cold), IEC (Test Bd, Operating Dry Heat), IEC (Test Nb, Operating Thermal Shock): C ( F) 65 C (149 F) IEC (Test Ab, Unpackaged Nonoperating Cold), IEC (Test Bb, Unpackaged Nonoperating Dry Heat), IEC (Test Na, Unpackaged Nonoperating Thermal Shock): C ( F) IEC (Test Db, Unpackaged Damp Heat): 5 95% non-condensing IEC (Test Fc, Operating): Hz Emissions CISPR 11 Group 1, Class A IEC (Test Ea, Unpackaged Shock): 25 g IEC (Test Ea, Unpackaged Shock): DIN mount: 25 g PANEL mount: 35 g ESD immunity IEC : 6 kv contact discharges 8 kv air discharges Radiated RF immunity IEC : 10V/m with 1 khz sine-wave 80% AM from MHz 10V/m with 200 Hz 50% Pulse 100% 900 MHz 10V/m with 200 Hz 50% Pulse 100% 1890 MHz 10V/m with 1 khz sine-wave 80% AM from MHz EFT/B immunity IEC : ±2 5 khz on power ports ±2 5 khz on signal ports Surge transient immunity IEC : ±1 kv line-line(dm) and ±2 kv line-earth(cm) on power ports ±1 kv line-line(dm) and ±2 kv line-earth(cm) on signal ports Conducted RF immunity IEC : 10V rms with 1 khz sine-wave 80% AM from 150 khz 80 MHz
30 28 Micro800 Programmable Controller Selection Guide Certifications Certification (when product is marked) (1) c-ul-us CE Value UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E European Union 2004/108/EC EMC Directive, compliant with: EN ; Meas./Control/Lab., Industrial Requirements EN ; Industrial Immunity EN ; Industrial Emissions EN ; Programmable Controllers (Clause 8, Zone A & B) European Union 2006/95/EC LVD, compliant with: EN ; Programmable Controllers (Clause 11) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions (1) See the Product Certification link at for Declaration of Conformity, Certificates, and other certification details. For relay life chart, see the Specifications section of the Micro830 and Micro850 User Manual, publication 2080-UM002. Embedded Serial Port Cable Selection Chart Embedded Serial Port Cables Connectors Length Cat. No. Connectors Length Cat. No. 8-pin Mini DIN to 8-pin Mini DIN 0.5 m (1.5 ft) 1761-CBL-AM00 (1) 8-pin Mini DIN to 9-pin D Shell 0.5 m (1.5 ft) 1761-CBL-AP00 (1) 8-pin Mini DIN to 8-pin Mini DIN 2 m (6.5 ft) 1761-CBL-HM02 (1) 8-pin Mini DIN to 9-pin D Shell 2 m (6.5 ft) 1761-CBL-PM02 (1) (1) Series C or later for Class 1 Div 2 applications. 8-pin Mini DIN to 6-pin RS-485 terminal block 30 cm (11.8 in.) 1763-NC01 series A
31 Select a Micro850 Controller A Micro850 controller with a power supply, plug-in modules, and four expansion I/O modules attached Micro850 controllers are suitable for applications that require more digital and analog I/O or higher performance analog I/O. These controllers can support up to four expansion I/O. It comes in a 24-point and 48-point form factor with an embedded Ethernet port. Micro850 controllers include: Expansion I/O support up to six embedded High-Speed Counter inputs (HSC) (1) 100 khz speed HSC available on 24V DC models up to three embedded Pulse Train Outputs (PTO) (2) for basic positioning High speed input interrupts Modbus RTU protocol (serial port) Modbus/TCP support EtherNet/IP support CIP Serial support Embedded USB programming and serial port (RS232/485) Embedded 10/100 Base-T Ethernet port (RJ45) Plug-in slots to customize according to needs To help you select a Micro850 controller, see the following specifications. (1) Embedded HSC is supported on all Micro850 catalog numbers, except on 2080-LC50-xxAWB. (2) PTO is supported on Micro850 catalog numbers ending in BB or VB. 29
32 30 Micro800 Programmable Controller Family Selection Guide Micro850 Controllers Number and Types of Inputs and Outputs Catalog Number Inputs Outputs PTO/ 120V AC 24V DC/ V AC 2080-LC50-24AWB Relay 24V Sink 24V Source PWM Support 2080-LC50-24QBB LC50-24QVB LC50-24QWB LC50-48AWB LC50-48QBB LC50-48QVB LC50-48QWB (1) Maximum number of HSC supported. HSC Support (1) Micro Point Controllers General Specifications 2080-LC50-24AWB, 2080-LC50-24QWB, 2080-LC50-24QVB, 2080-LC50-24QBB Attribute 2080-LC50-24AWB 2080-LC50-24QWB 2080-LC50-24QVB 2080-LC50-24QBB Number of I/O 24 (14 inputs, 10 outputs) Dimensions, HxWxD 90 x 158 x 80 mm (3.54 x 6.22 x 3.15 in.) Shipping weight, approx kg (0.933 lb)
33 Micro800 Programmable Controller Family Selection Guide 31 General Specifications 2080-LC50-24AWB, 2080-LC50-24QWB, 2080-LC50-24QVB, 2080-LC50-24QBB Attribute 2080-LC50-24AWB 2080-LC50-24QWB 2080-LC50-24QVB 2080-LC50-24QBB Wire size Min Max Solid 0.2 mm 2 (24 AWG) 2.5 mm 2 (14 AWG) 90 C (194 F) insulation max Stranded 0.2 mm 2 (24 AWG) 2.5 mm 2 (14 AWG) Wiring category (1) 2 on signal ports 2 on power ports 2 on communication ports Wire type Use copper conductors only Terminal screw torque 0.6 Nm (4.4 lb-in.) max (using a 2.5 mm (0.10 in.) flat-blade screwdriver) Input circuit type 120V AC 24V DC sink/source standard and high-speed Output circuit type Relay 24V DC sink standard and high-speed Power consumption 28 W Power supply voltage range V DC Class 2 I/O rating Input 120V AC 16 ma Output 2 A, 240 V AC, 24V DC Isolation voltage 250V (continuous), Reinforced Insulation Type, Output to Aux and Network, Inputs to Outputs. Type tested for V DC Output to Aux and Network, Inputs to Outputs 150V (continuous), Reinforced Insulation Type, Input to Aux and Network. Type tested for V DC Input to Aux and Network Input 24V, 8.8 ma Output 2 A, 240 V AC, 24V DC 250V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs. Type tested for V DC Output to Aux and Network, Inputs to Outputs. 50V (continuous), Reinforced Insulation Type, Input to Aux and Network Type tested for V DC, Inputs to Aux and Network. Pilot duty rating C300, R150 Insulation stripping length 7 mm (0.28 in.) Enclosure type rating Meets IP20 North American temp code T4 (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication V DC source standard and high-speed Input 24V, 8.8 ma Output 24V DC, Class 2, 1 A per point (surrounding air temperature 30 C) 24 V DC, Class 2, 0.3 A per point (surrounding air temperature 65 C) 50V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs. Type tested for V DC, I/O to Aux and Network, Inputs to Outputs.
34 32 Micro800 Programmable Controller Family Selection Guide DC Input Specifications 2080-LC50-24QBB, 2080-LC50-24QVB, 2080-LC50-24QWB Attribute High-Speed DC Input (Inputs 0 7) Number of Inputs 8 6 Voltage category Input group to backplane isolation On-state voltage range 24V sink/source Standard DC Input (Inputs 8 and higher) Verified by one of the following dielectric tests: 720V DC for 2 s 50V DC working voltage (IEC Class 2 reinforced insulation) V 65 C (149 F) V 30 C (86 F) V 65 C (149 F) V 30 C (86 F) Off-state voltage, max 5V DC Off-state current, max 1.5 ma On-state current, min V DC, min V DC, min On-state current, nom V DC, nom V DC, nom On-state current, max V DC, max V DC, max Nominal impedance 3 kω 3.74 kω IEC input compatibility Type 3
35 Micro800 Programmable Controller Family Selection Guide 33 AC Input Specifications 2080-LC50-24AWB Attribute Value Number of inputs 14 On-state voltage, min 79V AC, min On-state voltage, max 132V AC, max On-state current, min 5 ma On-state current, max 16 ma Input frequency, nom 50/60 Hz Input frequency, min 47 Hz Input frequency, max 63 Hz, max Off-state voltage, max 20V 120V AC Off-state current, max V AC Inrush current, max V AC Inrush delay time constant max 22 ms IEC input compatibility Type 3 Output Specifications Attribute 2080-LC50-24QWB, 2080-LC50-24AWB 2080-LC50-24QVB, 2080-LC50-24QBB Relay Output Hi-Speed Output (Outputs 0...1) Number of outputs Output voltage, min 5V DC, 5V AC 10.8V DC 10V DC Output voltage, max 125V DC, 265V AC 26.4V DC 26.4V DC Load current, min Load current, continuous, max 10 ma Refer to Relay Contacts Ratings on page ma (high-speed operation) C C (standard operation) Standard Output (Outputs 2 and higher) Surge current, per point Refer to Relay Contacts Ratings on page A for 10 ms every 1 30 C; every 2 65 C (1) Current, per common, max 5 A Turn on time/ Turn off time, max 10 ms 2.5 μs 0.1 ms 1 ms (1) Applies for general purpose operation only; does not apply for high-speed operation. Relay Contacts Ratings C C (standard operation) Maximum Volts Amperes Amperes Volt-Amperes Continuous Make Break Make Break 120V AC 15 A 1.5 A 2.0 A 1800V A 180V A 240V AC 7.5 A 0.75 A 24V DC 1.0 A 1.0 A 28V A 125V DC 0.22 A
36 34 Micro800 Programmable Controller Family Selection Guide For relay life chart, see the Specifications section of the Micro830 and Micro850 User Manual, publication 2080-UM002. Environmental Specifications Attribute Temperature, operating Temperature, surrounding air, max Temperature, non-operating Relative humidity Vibration Shock, operating Shock, non-operating Value IEC (Test Ad, Operating Cold), IEC (Test Bd, Operating Dry Heat), IEC (Test Nb, Operating Thermal Shock): C ( F) 65 C (149 F) IEC (Test Ab, Unpackaged Nonoperating Cold), IEC (Test Bb, Unpackaged Nonoperating Dry Heat), IEC (Test Na, Unpackaged Nonoperating Thermal Shock): C ( F) IEC (Test Db, Unpackaged Damp Heat): 5 95% non-condensing IEC (Test Fc, Operating): Hz Emissions CISPR 11 Group 1, Class A IEC (Test Ea, Unpackaged Shock): 25 g IEC (Test Ea, Unpackaged Shock): DIN mount: 25 g PANEL mount: 35 g ESD immunity IEC : 6 kv contact discharges 8 kv air discharges Radiated RF immunity IEC : 10V/m with 1 khz sine-wave 80% AM from MHz 10V/m with 200 Hz 50% Pulse 100% 900 MHz 10V/m with 200 Hz 50% Pulse 100% 1890 MHz 10V/m with 1 khz sine-wave 80% AM from MHz EFT/B immunity IEC : ±2 5 khz on power ports ±2 5 khz on signal ports ±1 5 khz on communication ports Surge transient immunity IEC : ±1 kv line-line(dm) and ±2 kv line-earth(cm) on AC power ports ±1 kv line-line(dm) and ±2 kv line-earth(cm) on signal ports ±1 kv line-earth(cm) on communication ports Conducted RF immunity IEC : 10V rms with 1 khz sine-wave 80% AM from 150 khz 80 MHz
37 Micro800 Programmable Controller Family Selection Guide 35 Certifications Certification (when product is marked) (1) c-ul-us CE Value UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E European Union 2004/108/EC EMC Directive, compliant with: EN ; Meas./Control/Lab., Industrial Requirements EN ; Industrial Immunity EN ; Industrial Emissions EN ; Programmable Controllers (Clause 8, Zone A & B) C-Tick EtherNet/IP KC European Union 2006/95/EC LVD, compliant with: EN ; Programmable Controllers (Clause 11) Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions ODVA conformance tested to EtherNet/IP specifications Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3 (1) See the Product Certification link at for Declaration of Conformity, Certificates, and other certification details. Micro Point Controllers General Specifications 2080-LC50-48AWB, 2080-LC50-48QWB, 2080-LC50-48QVB, 2080-LC50-48QBB Attribute 2080-LC50-48AWB 2080-LC50-48QWB 2080-LC50-48QVB 2080-LC50-48QBB Number of I/O 48 (28 inputs, 20 outputs) Dimensions, HxWxD 90 x 238 x 80 mm (3.54 x 9.37 x 3.15 in.) Shipping weight, approx kg (1.60 lb)
38 36 Micro800 Programmable Controller Family Selection Guide General Specifications 2080-LC50-48AWB, 2080-LC50-48QWB, 2080-LC50-48QVB, 2080-LC50-48QBB Attribute 2080-LC50-48AWB 2080-LC50-48QWB 2080-LC50-48QVB 2080-LC50-48QBB Wire size Min Max Solid 0.2 mm 2 (24 AWG) 2.5 mm 2 (14 AWG) 90 C (194 F), insulation max. Stranded 0.2 mm 2 (24 AWG) 2.5 mm 2 (14 AWG) Wiring category (1) 2 on signal ports 2 on power ports 2 on communication ports Wire type Use copper conductors only Terminal screw torque Nm ( lb-in.) (using a 0.6 x 3.5 mm flat-blade screwdriver) Input circuit type 120V AC 24V DC sink/source standard and high-speed Output circuit type Relay 24V DC sink standard and high-speed Power consumption 33 W Power supply voltage V DC Class 2 range I/O rating Input 120V AC, 16 ma Output 2 A, 240V AC, 2A, 24V DC Input 24V DC, 8.8 ma Output 2 A, 240V AC, 2 A, 24V DC 24V DC source standard and high-speed Input 24V DC, 8.8 ma Output 24V DC, 1 A per point (Surrounding air temperature 30 C) 24V DC, 0.3 A per point (Surrounding air temperature 65 C) Insulation stripping length 7 mm (0.28 in.) Enclosure type rating Meets IP20 Pilot duty rating C300, R150 Isolation voltage 250V (continuous), Reinforced Insulation Type, Output to Aux and Network, Inputs to Outputs Type tested for V DC Output to Aux and Network, Inputs to Outputs. 250V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs Type tested for V DC Output to Aux and Network, Inputs to Outputs. 50V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs Type tested for V DC, I/O to Aux and Network, Inputs to Outputs. 150V (continuous), Reinforced Insulation Type, Input to Aux and Network Type tested for V DC Input to Aux and Network North American temp code T4 50V (continuous), Reinforced Insulation Type, Input to Aux and Network Type tested for V DC, Inputs to Aux and Network (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication Input Specifications Attribute 2080-LC50-48AWB 2080-LC50-48QWB / 2080-LC50-48QVB / 2080-LC50-48QBB 120V AC Input High-Speed DC Input (Inputs 0 11) Standard DC Input (Inputs 12 and higher) Number of Inputs Input group to backplane isolation Verified by the following dielectric tests: 1950V AC for 2 s 150V working voltage (IEC Class 2 reinforced insulation) Verified by the following dielectric tests: 720V DC for 2 s 50V DC working voltage (IEC Class 2 reinforced insulation) Voltage category 110V AC 24V DC sink/source Operating voltage range 132V, 60Hz AC max V 65 C (149 F) V 30 C (86 F) V 65 C (149 F) V 30 C (86 F)
39 Micro800 Programmable Controller Family Selection Guide 37 Input Specifications Attribute 2080-LC50-48AWB 2080-LC50-48QWB / 2080-LC50-48QVB / 2080-LC50-48QBB Off-state voltage, max 20V AC 5V DC Off-state current, max 1.5 ma 1.5 ma On-state current, min 5 79V AC V DC V DC On-state current, nom V AC V DC V DC On-state current, max V AC V DC Nominal impedance IEC input compatibility Type Hz Hz Inrush current, max V AC Input frequency, max 63 Hz Output Specifications 3 kω 3.74 kω Attribute 2080-LC50-48AWB / 2080-LC50-48QWB 2080-LC50-48QVB / 2080-LC50-48QBB Relay Output Hi-Speed Output (Outputs 0 through 3) Number of outputs Output voltage, min 5V DC, 5V AC 10.8V DC 10V DC Output voltage, max 125V DC, 265V AC 26.4V DC 26.4V DC Load current, min 10 ma Load current, max 2.0 A 100 ma (high-speed operation) C C (standard operation) Standard Output (Outputs 4 and higher) Surge current, per point See Relay Contacts Ratings on page A for 10 ms every 1 30 C; every 2 65 C (1) Current, per common, max 5 A Turn on time/ Turn off time, max 120V AC Input 10 ms 2.5 μs 0.1 ms 1 ms (1) Applies for general purpose operation only. Does not apply for high-speed operation. Relay Contacts Ratings High-Speed DC Input (Inputs 0 11) Standard DC Input (Inputs 12 and higher) C C (standard operation) Maximum Volts Amperes Amperes Volt-Amperes Continuous Make Break Make Break 120V AC 15 A 1.5 A 2.0 A 1800V A 180V A 240V AC 7.5 A 0.75 A 24V DC 1.0 A 1.0 A 28V A 125V DC 0.22 A For relay life chart, see the Specifications section of the Micro830 and Micro850 User Manual, publication 2080-UM002.
40 38 Micro800 Programmable Controller Family Selection Guide Environmental Specifications Attribute Temperature, operating Temperature, surrounding air, max Temperature, non-operating Relative humidity Vibration Shock, operating Shock, non-operating Value IEC (Test Ad, Operating Cold), IEC (Test Bd, Operating Dry Heat), IEC (Test Nb, Operating Thermal Shock): C ( F) 65 C (149 F) IEC (Test Ab, Unpackaged Nonoperating Cold), IEC (Test Bb, Unpackaged Nonoperating Dry Heat), IEC (Test Na, Unpackaged Nonoperating Thermal Shock): C ( F) IEC (Test Db, Unpackaged Damp Heat): 5 95% non-condensing IEC (Test Fc, Operating): Hz Emissions CISPR 11 Group 1, Class A IEC (Test Ea, Unpackaged Shock): 25 g IEC (Test Ea, Unpackaged Shock): DIN mount: 25 g PANEL mount: 35 g ESD immunity IEC : 4 kv contact discharges 8 kv air discharges Radiated RF immunity IEC : 10V/m with 1 khz sine-wave 80% AM from MHz 10V/m with 200 Hz 50% Pulse 100% 900 MHz 10V/m with 200 Hz 50% Pulse 100% 1890 MHz 10V/m with 1 khz sine-wave 80% AM from MHz EFT/B immunity IEC : ±2 5 khz on power ports ±2 khz on signal ports ±1 5 khz on communication ports Surge transient immunity IEC : ±1 kv line-line(dm) and ±2 kv line-earth(cm) on power ports ±1 kv line-line(dm) and ±2 kv line-earth(cm) on signal ports ±1 kv line-earth(cm) on communication ports Conducted RF immunity IEC : 10V rms with 1 khz sine-wave 80% AM from 150 khz 80 MHz
41 Micro800 Programmable Controller Family Selection Guide 39 Certifications Certification (when product is marked) (1) c-ul-us CE Value UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E European Union 2004/108/EC EMC Directive, compliant with: EN ; Meas./Control/Lab., Industrial Requirements EN ; Industrial Immunity EN ; Industrial Emissions EN ; Programmable Controllers (Clause 8, Zone A & B) C-Tick EtherNet/IP KC European Union 2006/95/EC LVD, compliant with: EN ; Programmable Controllers (Clause 11) Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions ODVA conformance tested to EtherNet/IP specifications. Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3. (1) See the Product Certification link at for Declaration of Conformity, Certificates, and other certification details.
42 40 Micro800 Programmable Controller Family Selection Guide Notes:
43 Select Micro850 Expansion I/O The 2085 I/O expansion modules provide superior functionality in a small-sized low-cost package. A variety of digital and analog modules complement and extend the capabilities of Micro850 controllers by maximizing the flexibility of I/O count and type. Micro850 expansion I/O modules include high density discrete and analog I/O modules, including a high accuracy RTD and Thermocouple module. There are available solid state output modules which are recommended to reduce switching noise and for applications which require more switching cycles, than relays. Triac outputs are available for AC loads. Sink and source transistor outputs are available for DC loads. The following section provides the list of available Micro850 expansion I/O modules and their specifications. Micro850 Expansion I/O Modules Catalog Number Type Description 2085-IA8 Discrete 8-point, 120V AC input 2085-IM8 Discrete 8-point, 240V AC input 2085-OA8 Discrete 8-point, 120/240V AC Triac Output 2085-IQ16 Discrete 16-point, 12/24V DC Sink/Source Input 2085-IQ32T Discrete 32-point, 12/24V DC Sink/Source Input 2085-OV16 Discrete 16-point, 12/24V DC Sink Transistor Output 2085-OB16 Discrete 16-point, 12/24V DC Source Transistor Output 2085-OW8 Discrete 8-point, AC/DC Relay Output 2085-OW16 Discrete 16-point, AC/DC Relay Output 41
44 42 Micro800 Programmable Controller Family Selection Guide Micro850 Expansion I/O Modules Catalog Number Type Description 2085-IF4 Analog 4-channel, 14-bit isolated (2) voltage/current input 2085-IF8 Analog 8-channel, 14-bit isolated (2) voltage/current input 2085-OF4 Analog 4-channel, 12-bit isolated (2) voltage/current output 2085-IRT4 Specialty 4-channel, 16-bit RTD and TC isolated (2) input module 2085-ECR (1) Terminator 2085 bus terminator (1) The 2085-ECR bus terminator should always be the last module on the system, if any expansion I/O module is attached to the system. (2) Refers to isolation from field side wiring to controller, not channel-to-channel isolation. Discrete Expansion I/O 2085-IQ16 and 2085-IQ32T DC Sink/Source Input Modules (1) Attribute 2085-IQ IQ32T Number of inputs 16 sink/source 32 sink/source Dimensions, HxWxD Shipping weight, approx x 90 x 87 mm (1.75 x 3.54 x 3.42 in.) 220 g (7.76 oz) Bus current draw, max 170 5V DC 190 5V DC Wire size Wiring category (2) Terminal screw torque, max Input circuit type mm 2 ( AWG) solid or stranded copper wire 75 C (167 F ), or greater, 1.2 mm (3/64 in.) insulation max 2 on signal ports Nm ( lb-in.) (3) 24V AC/DC sink/source Power dissipation, total 4.5 W 7 W Power supply 24V DC Status indicators 16 yellow indicators 32 yellow indicators Isolation voltage 50V (continuous), Reinforced Insulation Type, channel to system Type 720V DC for 60 s Enclosure type rating Meets IP20 North American temp T4 code Operating voltage range 10 30V DC, Class V AC, Class 2 See Derating Curve for 2085-IQ16 and Derating Curve for 2085-IQ32T on page 43 Off-state voltage, max 5V DC
45 Micro800 Programmable Controller Family Selection Guide IQ16 and 2085-IQ32T DC Sink/Source Input Modules (1) Attribute 2085-IQ IQ32T Off-state current, max 1.5 ma 1.2 ma On-state current, min V DC On-state current, nom V DC V DC On-state current, max V DC V DC Input impedance, max 3.9 kω 4.6 kω IEC input compatibility Type 3 Type 1 (1) Meets IEC Type 1 24V DC Input Specifications. (2) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication (3) RTB hold down screws should be tightened by hand. They should not be tightened using a power tool. Derating Curve for 2085-IQ16 Input voltage (V) C 65 C Temp Derating Curve for 2085-IQ32T Input voltage (V) C C Number of inputs OV16 Sink and 2085-OB16 Source DC Output Module Attribute 2085-OV OB16 Number of outputs 16 sinking 16 sourcing Operating voltage range 10 30V DC On-state voltage, min 10V DC On-state voltage, nom 24V DC On-state voltage, max 30V DC On-state current, max V DC, per output 8 A, per module Dimensions, HxWxD 44.5 x 90 x 87 mm (1.75 x 3.54 x 3.42 in.)
46 44 Micro800 Programmable Controller Family Selection Guide 2085-OV16 Sink and 2085-OB16 Source DC Output Module Attribute 2085-OV OB16 Shipping weight, approx. 220 g (7.76 oz) Bus current draw, max 200 5V DC Wire size mm 2 ( AWG) solid or stranded copper wire 75 C (167 F ), or greater, 1.2 mm (3/64 in.) insulation max Wiring category (1) 2 on signal ports Terminal screw torque, max Nm ( lb-in.) (2) Output circuit type 24V DC sink 24V DC source Power dissipation, total 5 W Power supply 24V DC, Class 2 Status indicators 16 Yellow channel indicators Isolation voltage 50V (continuous), Reinforced Insulation Type, channel to system Type 720V AC for 60 s Enclosure type rating Meets IP20 North American temp code T4 (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication (2) RTB hold down screws should be tightened by hand. They should not be tightened using a power tool IA8, 2085-IM8, 2085-OA8 AC Input/Output Modules Attribute 2085-IA IM OA8 Number of inputs 8 Dimensions, HxWxD 28 x 90 x 87 mm (1.10 x 3.54 x 3.42 in.) Shipping weight, approx. 140 g (4.93 oz) Bus current draw, max 5V DC, 150 ma 5V DC, 180 ma Wire size mm 2 ( AWG) solid or stranded copper wire 75 C (167 F ), or greater, 1.2 mm (3/64 in.) insulation max Insulation stripping length 10 mm (0.39 in.) Wiring category (1) 2 on signal ports Wire type Copper Terminal screw torque, max Nm ( lb-in.) (2) Input/output circuit type 120V AC input 240V AC input 120V/240V AC output Power supply 120V AC 240V AC 120V/240V AC Power dissipation, total 2.36 W 2.34 W 5.19 W Enclosure type rating Meets IP20
47 Micro800 Programmable Controller Family Selection Guide IA8, 2085-IM8, 2085-OA8 AC Input/Output Modules Attribute 2085-IA IM OA8 Status indicators Isolation voltage North American temp code 8 yellow indicators 150V (continuous), Reinforced Insulation Type, channel to system Type 1950V DC for 60 s T4 240V (continuous), Reinforced Insulation Type, channel to system Type 3250V DC for 60 s (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication (2) RTB hold down screws should be tightened by hand. They should not be tightened using a power tool. Input Specifications 2005-IA8 and 2085-IM8 Attribute 2085-IA IM8 Number of Inputs 8 Voltage category 120V AC 240V AC Operating voltage range V AC V AC Off-state voltage, max 20V AC 40V AC Off-state current, max 2.5 ma On-state current, min V AC V AC On-state current, max V AC V AC Input impedance, max 22.2 kω Inrush current, max 450 ma Input filter time < 20 ms Off to On On to Off IEC type compliance Type 3 Output Specifications 2085-OA8 Attribute 2085-OA8 Number of Inputs 8 Voltage category 120V/230V AC Operating voltage range V AC Output voltage, min 85V AC Output voltage, max 240V AC Off-state current, max 2.5 ma On-state current, min 10 ma per output On-state current, max 0.5 A per output On-state current, per module, max 4 A Off-state voltage drop, max 1.5V 0.5 A 2.5V ma Fusing Not protected. A suitable rating fuse is recommended to protect outputs.
48 46 Micro800 Programmable Controller Family Selection Guide Output Specifications 2085-OA8 Attribute Output signal delay Off to On On to Off Surge current, max 2085-OA8 9.3 ms for 60 Hz, 11 ms for 50 Hz 9.3 ms for 60 Hz, 11 ms for 50 Hz 5 A 2085-OW8 and 2085-OW16 Relay Output Module Attribute 2085-OW OW16 Number of outputs 8, relay 16, relay Dimensions, HxWxD Shipping weight, approx. Wire size Insulation strip length Wiring category (1) Wire type Terminal screw torque. max Bus current draw, max Load current, max Power dissipation, total Relay contact, (0.35 power factor) 28 x 90 x 87 mm (1.10 x 3.54 x 3.42 in.) 44.5 x 90 x 87 mm (1.75 x 3.54 x 3.42 in.) 140 g (4.93 oz) 220 g (7.76 oz) mm 2 ( AWG) solid or stranded copper wire 75 C (167 F ), or greater, 1.2 mm (3/64 in.) insulation max 10 mm (0.39 in.) 2 on signal ports Copper Nm ( lb-in.) (2) 5V DC, 120 ma 24V DC, 50 ma 2 A 2.72 W 5.14 W 5V DC, 160 ma 24V DC, 100 ma Max Amperes Amperes Volt Amperes Volts Make Break Continuous Make Break 120V AC 15 A 1.5 A 2.0 A 1800V A 180V A 240V AC 7.5 A 0.75 A 24V DC 1.0 A 1.0 A 28V A 125V DC 0.22 A Minimum load, per 10 ma per point point Off-state leakage, max 1.5 ma Status indicators 8 yellow indicators 16 yellow indicators Isolation voltage 240V (continuous), Reinforced Insulation Type, channel to system Type 3250V DC for 60 s Pilot duty rating C300, R150 Enclosure type rating Meets IP20 North American temp T4 code (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication (2) RTB hold down screws should be tightened by hand. They should not be tightened using a power tool.
49 Micro800 Programmable Controller Family Selection Guide 47 Analog Expansion I/O 2085-IF4, 2085-IF8, 2085-OF4 Analog Input and Output Modules Attribute 2085-IF OF IF8 Number of I/O 4 8 Dimensions, HxWxD Shipping weight, approx. Bus current draw, max Wire size Wiring category (1) Wire type Terminal screw torque 28 x 90 x 87 mm (1.1 x 3.54 x 3.42 in.) 44.5 x 90 x 87 mm (1.75 x 3.54 x 3.42 in.) 140 g (4.93 oz) 220 g (7.76 oz) 5V DC, 100 ma 24V DC, 50 ma 5V DC, 160 ma 24V DC, 120 ma 5V DC, 110 ma 24V DC, 50 ma mm 2 ( AWG) solid or stranded copper wire 75 C (167 F ), or greater, 1.2 mm (3/64 in.) insulation max 2 on signal ports Shielded Nm ( lb-in.) (2) Power dissipation, total 1.7 W 3.7 W 1.75 W Enclosure type rating Status indicators Isolation voltage North American temp code Meets IP20 1 green health indicator 1 green health indicator 1 green health indicator 8 red error indicators 50V (continuous), Reinforced Insulation Type, channel to system and channel to channel. Type 720V DC for 60 s T4 (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication (2) RTB hold down screws should be tightened by hand. They should not be tightened using a power tool. Input Specifications 2085-IF4 and 2085-IF8 Attribute 2085-IF IF8 Number of inputs 4 8 Resolution Voltage Current Data format Conversion type Update rate Step response time up to 63% Input current terminal, user configurable Input voltage terminal, user configurable 14 bits (13 bits plus sign bit) 1.28 mv/cnt unipolar; 1.28 mv/cnt bipolar 1.28 μa/cnt Left justified, 16 bit 2s complement SAR < 2 ms per enabled channel without 50 Hz/60 Hz rejection, < 8 ms for all channel 8 ms with 50 Hz/60 Hz rejection 4 60 ms without 50Hz/60 Hz rejection depends on number of enabled channel and filter setting 600 ms with 50 Hz/60 Hz rejection 4 20 ma (default) 0 20 ma ±10V 0 10V
50 48 Micro800 Programmable Controller Family Selection Guide Input Specifications 2085-IF4 and 2085-IF8 Attribute 2085-IF IF8 Input impedance Absolute accuracy Accuracy drift with temp Calibration required Overload, max. Channel diagnostics Voltage terminal >1 MΩ Current terminal <100 Ω ±0.10% Full 25 C Voltage terminal % Full Scale/ C Current terminal % Full Scale/ C Factory calibrated. No customer calibration supported. 30V continuous or 32 ma continuous, one channel at a time. Over and under range or open circuit condition by bit reporting Output Specifications 2085-OF4 Attribute Number of outputs 4 Resolution Voltage Current Data format Step response time up to 63% Conversion rate, max Output current terminal, user configurable Output voltage terminal, user configurable Current load on voltage output, max Absolute accuracy Voltage terminal Current terminal Accuracy drift with temp Resistive load on ma output 2085-OF4 12 bits unipolar; 11 bits plus sign bipolar 2.56 mv/cnt unipolar; 5.13 mv/cnt bipolar 5.13 μa/cnt Left justified, 16 bit 2s complement 2 ms 2 ms per channel 0 ma output until module is configured 4 20 ma (default) 0 20 ma ±10V 0 10V 3 ma % Full 25 C or better % Full 25 C or better Voltage terminal % Full Scale/ C Current terminal % Full Scale/ C V DC Specialty Expansion I/O 2085-IRT4 Temperature Input Module Attribute Number of inputs 4 Dimensions, HxWxD Shipping weight, approx. Bus current draw, max 2085-IRT x 90 x 87 mm (1.75 x 3.54 x 3.42 in.) 220 g (7.76 oz) 5V DC, 160 ma 24V DC, 50 ma
51 Micro800 Programmable Controller Family Selection Guide IRT4 Temperature Input Module Attribute Wire size Wiring category (1) Terminal screw torque Input type Resolution Channel update time, typical Input impedance Accuracy Power dissipation, total Enclosure type rating Status indicators Isolation voltage North American temp code Environment Specifications 2085-IRT mm 2 ( AWG) solid or stranded copper wire 75 C (167 F ), or greater, 1.2 mm (3/64 in.) insulation max 2 on signal ports Nm ( lb-in.) (2) Thermocouple type: B, C, E, J, K, TXK/XK (L), N, R, S, T RTD type: 100 Ω Pt α = Euro 200 Ω Pt α = Euro 100 Ω Pt α = U.S 200 Ω Pt α = U.S. 100 Ω Nickel Ω Nickel Ω Nickel Ω Copper 427 mv range: mv Ohm input: Ω 16 bits ms per enabled channel > 10 M Ω ±0.5 ±3.0 C accuracy for Thermocouple inputs ±0.2 ±0.6 C accuracy for RTD inputs 2 W Meets IP20 1 green health indicator 50V (continuous), Reinforced Insulation Type, channel to system. Type 720V DC for 60 s T4 (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication (2) RTB hold down screws should be tightened by hand. They should not be tightened using a power tool. Environment Specifications for All Micro850 Expansion I/O Modules Attribute Temperature, operating Temperature, nonoperating Temperature, surrounding air, max. Relative humidity Vibration Value IEC (Test Ad, Operating Cold), IEC , (Test Bd, Operating Dry Heat), IEC (Test Nb, Operating Thermal Shock): C ( F) IEC (Test Ab, Unpackaged Nonoperating Cold), IEC (Test Bb, Unpackaged Nonoperating Dry Heat), IEC (Test Na, Unpackaged Nonoperating Thermal Shock): C ( F) 65 C (149 F) IEC (Test Db, Unpackaged Damp Heat): 5 95% noncondensing IEC (Test Fc, Operating): Hz
52 50 Micro800 Programmable Controller Family Selection Guide Environment Specifications for All Micro850 Expansion I/O Modules Attribute Shock, operating Value IEC (Test Ea, Unpackaged Shock): 25 g Shock, nonoperating IEC (Test Ea, Unpackaged Shock): 25 g for DIN Rail Mounting 35 g for Panel Mounting Emissions CISPR 11: Group 1, Class A ESD Immunity IEC : 6 kv contact discharges 8 kv air discharges Radiated RF Immunity IEC : 10V/m with 1 khz sine-wave 80% AM from MHz 10V/m with 200 Hz 50% Pulse 100% 900 MHz 10V/m with 200 Hz 50% Pulse 100% 1890 MHz 10V/m with 1 khz sine-wave 80% AM from MHz EFT/B Immunity IEC : ±2 5 khz on signal ports Surge Transient Immunity IEC : ±1 kv line-line(dm) and ±2 kv line-earth(cm) on power ports ±2 kv line-earth(cm) on shielded ports Conducted RF Immunity IEC : 10V rms with 1 khz sine-wave 80% AM from 150 khz 80 MHz Certifications All Micro800 Expansion I/O Modules Certification (when product is marked) (1) c-ul-us Value UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E CE C-Tick KC UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E European Union 2004/108/EC EMC Directive, compliant with: EN ; Meas./Control/Lab., Industrial Requirements EN ; Industrial Immunity EN ; Industrial Emissions EN ; Programmable Controllers (Clause 8, Zone A & B) Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3 (1) See the Product Certification link athttp:// for Declaration of Conformity, Certificates, and other certification details.
53 Select Micro800 Plug-in Modules and Accessories Micro800 plug-in modules extend the functionality of embedded I/O without increasing the footprint of the controller. It improves performance by adding additional processing power or capabilities and adds additional communication functionality. Micro820, Micro830 and Micro850 controllers support plug-in modules. Micro800 accessories consist of a Remote LCD (compatible with Micro820 only), an LCD with keypad (compatible with Micro810 only), a USB adapter (compatible with Micro810 only), and an expansion power supply. 51
54 52 Micro800 Programmable Controller Family Selection Guide Micro800 Plug-in Modules and Accessories Features and Compatibility Plug-in / Accessory 1.5" LCD and Keypad 2080-LCD Micro810 USB Adapter 2080-USBADAPTER External Power Supply 2080-PS VAC RS232/485 Isolated Serial Port 2080-SERIALISOL Digital Input, Output, Relay, and Combination Modules 2080-IQ4, 2080-IQ4OB4, 2080-IQ4OV4, 2080-OB4, 2080-OV4, 2080-OW4I High Speed Counter 2080-MOT-HSC DeviceNet Scanner 2080-DNET20 Remote LCD 2080-REMLCD Non-isolated Unipolar Analog Input/Output 2080-IF2, 2080-IF4, 2080-OF2 Non-isolated Thermocouple 2080-TC2 Non-isolated RTD 2080-RTD2 Memory Module with RTC 2080-MEMBAK-RTC 6-Channel Trim Potentiometer Analog Input 2080-TRIMPOT6 Supported by Micro810 Supported by Micro820 Supported by Micro830/Micro850 Feature Yes No No backup module for Micro810 controllers configure Smart Relay Function Blocks Yes No No USB programming access Yes Yes Yes optional controller power supply No Yes Yes adds additional serial communications with Modbus RTU and ASCII protocols isolated for increased noise immunity No Yes Yes 4-channel inputs/outputs or combination modules configurable as voltage and current inputs sink or source output 4-channel relay outputs No Yes Yes Up to a minimum of 250 KHz differential line driver for improved noise immunity and additional dedicated I/O One Quadrature (ABZ) differential inputs alternately configurable for pulse internal, pulse with external direction, A-up and B-down input configurations, and quadrature mode User-configurable minimum and maximum values, preset, and Z operation No Yes Yes Scanner mode scan devices such as CompactBlock LDX, PowerFlex drives, overloads and sensors No Yes No Operator interface for configuring such settings as IP address on Micro820 controller With RS232 and USB ports No Yes Yes adds up to 20 embedded analog I/O with 12-bit resolution (with 48-point controllers) 2 channels for 2080-IF2, 2080-OF2 4 channels for 2080-IF4 No Yes Yes for temperature control, when used with PID 2 channels for 2080-TC2 and 2080-RTD2 No Yes Yes No No Yes backup project data and application code high accuracy real-time clock No Yes Yes adds six analog presets for speed, position and temperature control
55 Micro800 Programmable Controller Family Selection Guide 53 Micro800 Plug-In Modules Digital Input, Output, Relay, and Combination Plug-Ins Specifications (2080-IQ4, 2080-IQ4OB4, 2080-IQ4OV4, 2080-OB4, 2080-OV4) Catalog Input / Output On-state voltage On-state current 2080-IQ4 4 inputs DC 9.0V DC, min 30V DC, max AC 10.25V AC (rms), min 30V AC (rms), max 2080-IQ4OB IQ4OV4 4 channel inputs/source outputs combination 4 channel inputs/sink outputs combination DC Input 9.0V DC, min 30V DC, max AC Input 10.25V AC (rms), min 30V AC (rms), max Output 10V DC, min 24V DC, nom 30V DC, max 2080-OB4 4 source outputs 10V DC, min 2080-OV4 4 sink outputs 24V DC, nom 30V DC, max DC 2.0 9V DC, min V DC, nom 5.0 ma, max AC 2.0 9V AC (rms), min 5.0 ma, max DC Input 2.0 9V DC, min V DC, nom 5.0 ma, max AC Input 2.0 9V AC (rms), min 5.0 ma, max Output V DC, min 0.5 A max, steady state 2 A surge, 2 s min V DC, min 0.5 A max, steady state 2 A surge, 2 s min
56 54 Micro800 Programmable Controller Family Selection Guide Specifications (2080-IQ4, 2080-IQ4OB4, 2080-IQ4OV4, 2080-OB4, 2080-OV4) Catalog Off-state voltage Off-state current Power supply voltage Mounting torque Status indicators 2080-IQ4 DC DC 0.2 Nm 4 yellow T4 5V DC, max 1.5 ma, max (1.48 lb-in.) 2080-IQ4OB4 AC 10.8V DC, min 8 yellow 3.5V AC (rms) 30V DC, max 2080-IQ4OV OB4, 2080-OV4 4 yellow North American temp code Catalog Terminal base screw torque Isolation voltage Wire size 2080-IQ Nm ( lb-in.) using a 2.5 mm (0.10 in.) flat-blade screwdriver 50V (continuous), Basic Insulation Type, Inputs to Backplane Type tested for V DC, Inputs to Backplane 2080-IQ4OB IQ4OV OB OV4 50V (continuous), Basic Insulation Type, Inputs to Outputs, I/Os to Backplane Type tested for V DC, I/Os to Backplane mm 2 ( AWG) solid or stranded copper wire 90 C (194 F), or greater, insulation max Catalog Operating temperature Non-operating temperature Surrounding air, max Relative humidity Vibration Shock, operating Shock, non-operating 2080-IQ C 2080-IQ4OB4 ( F) C ( F) 65 C (149 F) 5 95% noncondensing Hz 25 g 25 g 2080-IQ4OV OB OV4 Specifications (2080-OW4I) Catalog Input/Output Inrush current Backplan e power Output current, resistive Output current, inductive Output power, resistive, max 2080-OW4I 4-channel relay output < V <120 24V 3.3 VDC, 38 ma V DC V DC V DC 2 125V AC 2 240V AC 1.0 A steady 5 28V DC 0.93 A steady 30V DC 0.5 A steady 48V DC 0.22 A steady 125V DC 2.0 A steady state, 15 A 125V AC, PF cos θ = A steady state, 7.5 A 240V AC, PF cos θ = V A for 125V AC resistive loads 480V A for 240V AC resistive loads 60V A for 30V DC resistive loads 24V A for 48V DC resistive loads 27.5V A for 125V DC resistive loads
57 Micro800 Programmable Controller Family Selection Guide 55 Catalog Output power, inductive break, max Pilot duty rating 2080-OW4I 180 VA for 125V AC inductive loads 180 VA for 240V AC inductive loads 28 VA for 28.8V DC inductive loads 28 VA for 48V DC inductive loads 28 VA for 125V DC inductive loads Minimum load, per point Initial contact resistance of relay, max Output delay time, max C300, R ma 30 mω 10 ms ON or OFF Catalog Relay contact, (0.35 power factor) Volts, max Amperes Amperes Volt-Amperes Make Break Continuous Make Break 2080-OW4I 120V AC 15 A 1.5 A 2.0 A 1800V A 180V A 240V AC 7.5 A 0.75 A 24V DC 1.0 A 1.0 A 28V A 125V DC 0.22 A Catalog Operating temperature Non-operating temperature Surrounding air, max Relative humidity Vibration Shock, operating Shock, non-operating 2080-OW4I C ( F) C ( F) 65 C (149 F) 5 95% noncondensing Hz 10 g DIN rail mounting: 25 g Panel mounting: 35 g Analog Input and Output Plug-ins Specifications (2080-IF2, 2080-IF4, 2080-OF2) Catalog 2080-IF IF OF2 Number of inputs/ outputs 2 inputs, unipolar non-isolated 4 inputs, unipolar non-isolated 2 outputs, unipolar non-isolated Voltage range Current range Power consumption 0 10V 0 20 ma <60 3.3V Input impedance >100 kω for voltage mode 250 Ω for current mode Voltage resistive load <60 24V 1 kω, min Catalog Current resistive load Mounting torque Terminal screw torque Wire size Operating temp. Non-operating temp. Surrounding air, max North American temp code 2080-IF2 0.2 Nm 2080-IF4 (1.48 lb-in.) 2080-OF2 500 Ω Nm ( lb-in.) using a 2.5 mm (0.10 in.) flat-blade screwdriver Solid: 0.14 mm 2 (26 AWG), min 1.5 mm 2 (16 AWG), max Stranded: 0.14 mm 2 (26 AWG), min 1.0 mm 2 (18 AWG), max 90 C (194 F ) insulation max C ( F) C ( F) 65 C (149 F) T4
58 56 Micro800 Programmable Controller Family Selection Guide Thermocouple and RTD (2080-TC2, 2080-RTD2) Specifications (2080-RTD2, 2080-TC2) Catalog Type Common mode rejection ratio 2080-RTD2 2-channel non-isolated RTD TC2 2-channel non-isolated Thermocouple 50/60Hz Normal mode rejection ratio 70 50/60 Hz Catalog Type Common mode rejection ratio 2080-RTD TC2 2-channel non-isolated RTD 2-channel non-isolated Thermocouple /60Hz Normal mode rejection ratio RTD types supported 70 50/60 Hz 100 Ω Platinum 385, 200 Ω Platinum 385, 500 Ω Platinum 385, 1000 Platinum 385, 100 Ω Platinum 392, 200 Ω Platinum 392, 500 Ω Platinum 392, 1000 Ω Platinum 392, 10 Ω Copper 427, 120 Ω Nickel 672, 604 Ω Nickel-Iron 518 Thermocouple types supported J, K, N, T, E, R, S, B Terminal screw torque Nm ( lb-in.) using a 2.5 mm (0.10 in.) flat-blade screwdriver Catalog Wire size Operating temperature 2080-RTD TC2 Solid: 0.14 mm 2 (26 AWG), min 1.5 mm 2 (16 AWG), max Stranded: 0.14 mm 2 (26 AWG), min 1.0 mm 2 (18 AWG), max 90 C (194 F ) insulation max C ( F) Non-operating temperature C ( F) Surrounding air, max 65 C (149 F) T4 North American temp code Trimpot Analog Input (2080-TRIMPOT6) Specifications (2080-TRIMPOT6) Numberof inputs Mounting torque Operating temperature Non-operating temperature Surrounding air, max North American temp code 6-channel, Trimpot 0.2 Nm (1.48 lb-in.) C ( F) C ( F) 65 C (149 F) T4
59 Micro800 Programmable Controller Family Selection Guide 57 Memory Backup and High Accuracy RTC Plug-In (2080-MEMBAK-RTC) Specifications (2080-MEMBAK-RTC) Mounting torque Terminal screw torque Operating temperature Non-operating temperature Surrounding air, max North American temp code 0.2 Nm (1.48 lb-in) Nm ( lb-in.) using a 2.5 mm (0.10 in.) flat-blade screwdriver C ( F) C ( F) 65 C (149 F) T4 RS232/485 Serial Port Plug-in (2080-SERIALISOL) Specifications (2080-SERIALISOL) Mounting torque 0.2 Nm (1.48 lb-in) Terminal screw torque Wire size Isolation voltage Nm ( lb-in) using a 2.5 mm (0.10 in.) flat-blade screwdriver Solid: mm 2 (26 16 AWG) Stranded: mm 2 (26 18 AWG) 90 C (194 F ) insulation max 500V AC Operating temperature Non-operating temperature C ( F) C ( F) Surrounding air, max 65 C (149 F) T4 North American temp code
60 58 Micro800 Programmable Controller Family Selection Guide DeviceNet (2080-DNET20) Specifications (2080-DNET20) DeviceNet Communication Rate, max DeviceNet current Wire size 125 Kbps 420 m (1378 ft.) 250 Kbps 200 m (656 ft.) 500 Kbps 75 m (246 ft.) 24V DC, 300 ma Class mm 2 ( AWG) solid or stranded copper wire 75 C (167 F ), or greater, 1.2 mm (3/64 in.) insulation max Network protocol I/O Slave Messaging: Poll Command Backplane power consumption Power dissipation Number of nodes, max 50 24V DC 1.44 W 20 nodes for I/O operation High Speed Counter (2080-MOT-HSC) Specifications (2080-MOT-HSC) Input Frequency, max 250 khz (50% duty) Wire size Solid: mm 2 (26 16 AWG) Stranded: mm 2 (26 18 AWG) 90 C (194 F ) insulation max Number of inputs 1 Quadrature (ABZ) differential input Input impedance Pulse width, min All supply power and/or current ratings Isolation voltage 3580 Ω 2 μs Input/Output: 24V DC Input module: 50V (continuous), Basic Insulation Type, Inputs/Outputs to Backplane. Type tested for 720V DC, Inputs/Outputs to Backplane Micro800 Accessories Micro810 LCD (2080-LCD) Operating temperature C ( F) Temperature, surrounding air, max Temperature, nonoperating 55 C (131 F) C ( F) T5 North American temp code Micro810 USB Adapter (2080-USBADAPTER) USB cable connector type USB Type A-B Male-Male Temperature, operating C ( F) Temperature, surrounding air, max Temperature, non-operating 55 C (131 F) C ( F) North American temp code T5
61 Micro800 Programmable Controller Family Selection Guide 59 External Power Supply (2080-PS VAC) Attribute Dimensions, HxWxD Shipping weight Supply voltage range (1) Remote LCD (2080-REMLCD) Value 90 x 45 x 80 mm (3.55 x 1.78 x 3.15 in) 0.34 kg (0.75 lb) 100V 120V AC, 1A V AC, 0.5A Supply frequency Hz Supply power 24V DC, 1.6 A Inrush current, max V for 10 ms V for 10 ms Power consumption (2) V AC, V AC (Output power) Power dissipation V AC, 240V AC (Input power) Isolation voltage 250V (continuous), Primary to Secondary: Reinforced Insulation Type Type tested for 2300V AC primary to secondary and 1480V AC primary to earth ground. Output ratings 24V DC, 1.6 A, 38.4 W max. (1) Any fluctuation in voltage source must be within 85V...264V. Do not connect the adapter to a power source that has fluctuations outside of this range. (2) When setting up a Micro800 system, verify that total power consumption of the controller, plug-in and expansion I/O does not exceed the output power capacity of the power supply used. Attribute Value Dimensions, HxWxD 97 x 130 x 35.5 mm (3.82 x 5.12 x 1.40 in.) Display type 192 x 64 pixel monochrome Display size 48 x mm (1.89 x 4.19 in.) Backlight C LED; tricolor backlight (RGB) Operator input Tactile keys (function keys, arrow keys, ESC and OK keys) Programming port USB to serial converter for programming the controller Input supply voltage 12V/24V DC (±10%) Input supply current, max 90 12V and 60 24V Power consumption, max 1.5 W Weight, approx. 405 g (0.89 lb) includes packaging weight Wire size Single-wire gauge: mm 2 (26 16 AWG) 90 C (194 F) Dual-wire gauge: mm 2 (26 18 AWG) 90 C (194 F) Wire type Copper Wiring category (1) 3 on power ports; 3 on communication port Enclosure type ratings Meets IP65 (when front panel mounted) North American temp code T4 (1) Use this conductor category information.
62 60 Micro800 Programmable Controller Family Selection Guide For More Information Visit the Micro800 website at to learn more about Micro800 products and download Connected Component Workbench software and Micro800 firmware updates. If you would like a manual, you can: download a free electronic version from the Internet: purchase a printed manual by contacting your local Allen-Bradley distributor or Rockwell Automation representative. You can also visit the following websites for additional technical information: Sample Code Library nts/webassets/sc_home_page.hcst Technical Forums Connected Component Accelerator Toolkit Additional Resources These documents contain additional information concerning related Rockwell Automation products. Resource Micro810 Programmable Controllers User Manual, publication 2080-UM001 xxxxx Micro820 Programmable Controllers User Manual, publication 2080-UM005 Micro830 and Micro850 Programmable Controllers User Manual, publication 2080-UM002 xxxxxxx Micro800 Plug-in Modules User Manual, publication 2080-UM004 Micro800 Discrete and Analog Expansion I/O Modules User Manual, publication 2080-UM003 Industrial Automation Wiring and Grounding Guidelines, publication Product Certifications website, cts/certification/ Description A more detailed description of how to install and use your Micro810 programmable controller. A more detailed description of how to install and use your Micro820 programmable controllers. A more detailed description of how to install and use your Micro830 and Micro850 programmable controller. Description of features, installation, wiring, and specifications for the Micro800 plug-in modules. Description of features, installation, wiring, and specifications for the Micro800 expansion I/O modules and accessories. Provides general guidelines for installing a Rockwell Automation industrial system. Provides declarations of conformity, certificates, and other certification details.
63
64 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration, and troubleshooting, we offer TechConnect support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit Installation Assistance If you experience a problem within the first 24 hours of installation, review the information that is contained in this manual. You can contact Customer Support for initial help in getting your product up and running. United States or Canada Outside United States or Canada Use the Worldwide Locator at or contact your local Rockwell Automation representative. New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures. United States Outside United States Contact your distributor. You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process. Please contact your local Rockwell Automation representative for the return procedure. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat: İçerenköy, İstanbul, Tel: +90 (216) Supersedes Publication 2080-SG001C-EN-P September 2012 Copyright 2013 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Micro800 Programmable Controllers. Bulletin 2080 Selection Guide
Micro800 Programmable Controllers Bulletin 2080 Selection Guide Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
1788 Linking Device Specifications
Technical Data 1788 Linking Device Specifications Catalog Numbers 1788-EN2DNROM, 1788-EN2DNR, 1788-EN2FFR, 1788-EN2PAR, 1788-CN2DN, 1788-CN2FFR, 1788-CN2PAR, 1788-FBJB4R, 1788-FBJB6 Topic Page 1788-EN2DNR
1756 ControlLogix Chassis Specifications
Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,
1756 ControlLogix Power Supplies Specifications
Technical Data 1756 ControlLogix Power Supplies Specifications Standard Power Supplies Catalog Numbers 1756-PA72, 1756-PA75, 1756-PB72, 1756-PB75, 1756-PC75, 1756-PH75 Standard Slim Power Supplies Catalog
1756 ControlLogix I/O Specifications
Technical Data 1756 ControlLogix I/O Specifications Catalog Numbers 1756 series Topic Page Additional Resources 1 Available 1756 I/O Modules 2 ControlLogix I/O Accessories 218 The ControlLogix architecture
1756 ControlLogix Integrated Motion Modules Specifications
Technical Data 1756 ControlLogix Integrated Motion Modules Specifications SERCOS Motion Catalog Numbers 1756-M03SE, 1756-M08SE, 1756-M16SE, 1756-M08SEG Analog Motion Catalog Numbers 1756-M02AE, 1756-M02AS,
USB-to-Data Highway Plus Cable
Installation Instructions USB-to-Data Highway Plus Cable Catalog Number 1784-U2DHP Topic Page Important User Information 2 Environment and Enclosure 3 Install the Cable 5 Configure the DH+ Node Address
PanelView 800 Terminals
Technical Data PanelView 800 Terminals Catalog Numbers 2711R-T4T, 2711R-T7T, 2711R-T10T Topic Page Environmental Specifications 3 General Specifications 4 Certifications 4 Technical Specifications 5 Product
PanelView Component Specifications
Technical Data PanelView Component Specifications Catalog Numbers 2711C-F2M, 2711C-K2M, 2711C-T3M, 2711C-K3M, 2711C-T4T, 2711C-T6M, 2711C-T6T, 2711C-T10C Topic Page Environmental Specifications 2 General
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Bimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
1769 Compact I/O Modules Specifications
Technical Data 1769 Compact I/O Modules Specifications Catalog Numbers 1769 Series Topic Page Summary of Changes 2 I/O Module Overview 2 Place Compact I/O Modules 4 Digital I/O Modules 4 Analog I/O Modules
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module
DATASHEET NI 9423 8-Channel Sinking Digital Input Module 8-channel, 100 µs digital input 24 V logic, sinking digital input Compatible with NI CompactDAQ counters 250 Vrms, CAT II isolation 10-position
MicroLogix 1100 Programmable Controllers
Installation Instructions MicroLogix 1100 Programmable Controllers Catalog Numbers 1763-L16AWA, 1763-L16BWA, 1763-L16BBB, 1763-L16DWD Topic Page Important User Information 4 Additional Resources 5 Overview
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
Universal Serial Bus (USB) to DH-485 Interface Converter
Installation Instructions Universal Serial Bus (USB) to DH-485 Interface Converter Catalog Number 1747-UIC Contents Overview..................................................3 Computer and Operating System
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Compact I/O End Caps/Terminators
Installation Instructions Compact I/O End Caps/Terminators Catalog Numbers 1769-ECL, 1769-ECR Topic Page Important User Information 2 Environment and Enclosure 3 North American Hazardous Location Approval
STRATO LED Drivers 70W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
Analog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
Stratix Ethernet Switch Specifications
Technical Data Stratix Ethernet Switch Specifications Stratix 5700 Catalog Numbers 1783-BMS06SL, 1783-BMS06SA, 1783-BMS06TL, 1783-BMS06TA, 1783-BMS06SGL, 1783-BMS06SGA, 1783-BMS06TGL, 1783-BMS06TGA, 1783-BMS10CL,
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB
Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h
CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC
E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules
3500/62 Process Variable Monitor
3500/62 Process Variable Monitor Description The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters (pressures, flows, temperatures, levels, etc.) that merit
Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P
Technical Data Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Topic Page 1609-P Specifications 2 1609-P Approximate Dimensions and Shipping Weights 3 Additional Resources
MICROLOGIX PROGRAMMABLE CONTROLLERS SELECTION GUIDE
MICROLOGIX PROGRAMMABLE CONTROLLERS SELECTION GUIDE BULLETIN 1761 MicroLogix 1000 BULLETIN 1763 MicroLogix 1100 BULLETIN 1762 MicroLogix 1200 BULLETIN 1766 MicroLogix 1400 BULLETIN 1764 MicroLogix 1500
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment
XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment Part of the device networking family of networkenablement products, XPress-Pro SW series
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
ControlNet Standard and High-flex Coax Cable
Installation Instructions ControlNet Standard and High-flex Coax Cable Catalog Number 1786-RG6/A and 1786-RG6F/B About This Document This document contains application information you need to consider
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
PHOENIX CONTACT - 2012-12-14. Features
Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
NX safety stand-alone
NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
Foxboro Evo Process Automation System
Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module
MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
1701/22 FieldMonitor Management Interface Module
1701/22 FieldMonitor Management Interface Module Bently Nevada Asset Condition Monitoring Description The 1701/22 FieldMonitor Management Interface Module (FMIM) is a highlyintegrated module that provides
SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade
Installation Instructions SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade Catalog Numbers 1747-DU501 Topic Page System Requirements 3 Install ControlFLASH 3 Prior to Running ControlFLASH
80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 6 A 80. Multi-function and mono-function timer range - Multi-function & multi-voltage 80. - ON delay, multi-voltage 7.5 mm wide Six time scales from 0.s to 24h 35 mm rail (EN
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Relés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.
SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,
Optimize your simple machines... Modicon M218 Selection Guide
Optimize your simple machines... Modicon M218 Selection Guide Compact Solution for Simple Machines Optimized Logic Controller Modicon M218 With intelligent software platform, specialized functional s,
CQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
SCADAPack 530E 535E. remote Programmable Automation Controller
SCADAPack 530E 535E remote Programmable Automation Controller 1 With the SCADAPack 500E range, Schneider Electric introduces the first ever remote Programmable Automation Controller (rpac). This data sheet
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give
C13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19
C13 C13 Document ID: 2CMC486004M0201 2013-06-19 Disclaimer Copyrights Trademarks Contact The information in this document is subject to change without notice and should not be construed as a commitment
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide
31007950 7/2009 ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide 7/2009 31007950.02 www.schneider-electric.com NOTICE Read these instructions carefully, and look at the equipment to become
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
Molded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
Vision OPLC. V350-35-R34/V350-J-R34 Technical Specifications. Technical Specifications
Vision OPLC V350-35-R34/V350-J-R34 Technical Specifications The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3
NI USB-5681 RF Power Meter Specifications
NI USB-568 RF Power Meter Specifications General This document lists specifications for the NI USB-568 RF power meter. Minimum or maximum specifications are warranted under the following conditions: hour
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited