Compact I/O High-speed Counter Module
|
|
|
- Magdalen Hodges
- 9 years ago
- Views:
Transcription
1 Installation Instructions Compact I/O High-speed Counter Module Catalog Number 1769-HSC Topic Page Important User Information 2 Environment and Enclosure 3 North American Hazardous Location Approval 4 Module Features 5 Hardware Description 6 Module Installation 7 System Planning 8 System Assembly 8 System Mounting 10 Replace the Module within a System 12 Field Wiring Connections 13 Output Operation 20 Module Powerup 22 Temperature Derating 23 Specifications 26 Additional Resources 30 About the Module The 1769-HSC module has six differential DC inputs that can be used as two to four high-speed counters. The module has 4 sourcing DC outputs and 12 additional virtual outputs. The counters provide accumulated pulse counts to the input array of the module and can cause onboard outputs to react to input conditions at high speed. The module is compatible with CompactLogix controllers, MicroLogix 1500 controllers, and the 1769-ADN DeviceNet adapter.
2 2 Compact I/O High-speed Counter Module Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at describes some important differences between solid-state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid-state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard and recognize the consequences. SHOCK HAZARD: Labels may be on or inside the equipment, for example, drive or motor, to alert people that dangerous voltage may be present. BURN HAZARD: Labels may be on or inside the equipment, for example, drive or motor, to alert people that surfaces may reach dangerous temperatures. IMPORTANT Identifies information that is critical for successful application and understanding of the product.
3 Compact I/O High-speed Counter Module 3 Environment and Enclosure ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC publication ), at altitudes up to 2000 m (6562 ft) without derating. This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR 11. Without appropriate precautions, there may be difficulties with electromagnetic compatibility in residential and other environments due to conducted and radiated disturbances. This equipment is supplied as open-type equipment. It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts. The enclosure must have suitable flame-retardant properties to prevent or minimize the spread of flame, complying with a flame spread rating of 5VA, V2, V1, V0 (or equivalent) if non-metallic. The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications. In addition to this publication, see: Industrial Automation Wiring and Grounding Guidelines, Rockwell Automation publication , for additional installation requirements. NEMA Standard 250 and IEC 60529, as applicable, for explanations of the degrees of protection provided by different types of enclosure. Prevent Electrostatic Discharge ATTENTION: This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment: Touch a grounded object to discharge potential static. Wear an approved grounding wriststrap. Do not touch connectors or pins on component boards. Do not touch circuit components inside the equipment. Use a static-safe workstation, if available. Store the equipment in appropriate static-safe packaging when not in use.
4 4 Compact I/O High-speed Counter Module North American Hazardous Location Approval The following information applies when operating this equipment in hazardous locations. Products marked "CL I, DIV 2, GP A, B, C, D" are suitable for use in Class I Division 2 Groups A, B, C, D, Hazardous Locations and nonhazardous locations only. Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code. When combining products within a system, the most adverse temperature code (lowest "T" number) may be used to help determine the overall temperature code of the system. Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of installation. WARNING: Explosion Hazard - Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous. Do not disconnect connections to this equipment unless power has been removed or the area is known to be nonhazardous. Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this product. Substitution of any component may impair suitability for Class I, Division 2. If this product contains batteries, they must only be changed in an area known to be nonhazardous. Informations sur l utilisation de cet équipement en environnements dangereux. Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne conviennent qu'à une utilisation en environnements de Classe I Division 2 Groupes A, B, C, D dangereux et non dangereux. Chaque produit est livré avec des marquages sur sa plaque d'identification qui indiquent le code de température pour les environnements dangereux. Lorsque plusieurs produits sont combinés dans un système, le code de température le plus défavorable (code de température le plus faible) peut être utilisé pour déterminer le code de température global du système. Les combinaisons d'équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l'installation. AVERTISSEMENT: Risque d Explosion Couper le courant ou s'assurer que l'environnement est classé non dangereux avant de débrancher l'équipement. Couper le courant ou s'assurer que l'environnement est classé non dangereux avant de débrancher les connecteurs. Fixer tous les connecteurs externes reliés à cet équipement à l'aide de vis, loquets coulissants, connecteurs filetés ou autres moyens fournis avec ce produit. La substitution de tout composant peut rendre cet équipement inadapté à une utilisation en environnement de Classe I, Division 2. S'assurer que l'environnement est classé non dangereux avant de changer les piles.
5 Compact I/O High-speed Counter Module 5 Module Features The 1769-HSC module is a 1 MHz counter/encoder input module with 4 onboard 5 30V DC sourcing outputs designed for high-speed control applications, such as flow control, measuring length, position, speed, frequency, or duration. The module can simultaneously interface with a maximum of two quadrature incremental encoders or four single-input count inputs from devices, such as proximity sensors, photo-eyes, single-pulse output encoders (with or without direction), or similar products used to monitor counting, flow, or frequency. The input voltage range is V DC. The 1769-HSC module includes all of the standard 1769 I/O module features, such as rackless, removable terminal block, integrated high-speed bus/backplane, panel, or DIN rail mounting. These are additional features: Two quadrature (ABZ) differential inputs alternately configurable for the following: Pulse internal direction input (four counters in this configuration) Pulse external direction input Up and down pulse input X1, X2, or X4 quadrature encoder input 32-bit count values (±2 billion counts) 21-bit rate values (±1 MHz) User-definable minimum and maximum count values Individual counter reset function (0 = reset enable (default); 1 = reset disable) 1769-HSC series B module only 16 user-defined ranges with each range individually assignable to 1 of the 4 counter channels User-definable preset Linear or ring counter operation Selectable input filters 5 30V DC counter/encoder inputs and control outputs 4 real (physical) outputs and 12 virtual (control bit) outputs Real outputs have electric overcurrent protection and rated current of 0.5 A per channel Safe State control options (options depend on which controller is used) to allow the module to operate during fault or program conditions
6 6 Compact I/O High-speed Counter Module Hardware Description 9a 1 2a 8a 8a 5a 5 IN OUT A0 B0 Z0 A1 B1 Z1 High Speed Counter DANGER Do Not Remove RTB Under Power Unless Area is Non-Hazardous OUT DC +5V/24V OUT 0 OUT 1 OUT 2 OUT 3 OUT DC COM A0+ A0- B0+ B0- Z0+ Z0-3 6a 10 IN OUT A0 B0 Z0 A1 B1 Z1 High Speed Counter 6b 5b A1+ A1- B1+ B1- Z1+ Z1- Ensure Adjacent Bus Lever is Unlatched/Latched Before/After Removing/Inserting Module 1769-HSC 4 7 2b 8b 8b 9b Item Description 1 Bus lever 2a Upper-panel mounting tab 2b Lower-panel mounting tab 3 Module status indicators (6 Input, 4 Output, 1 Fuse, 1 OK) 4 Module door with terminal identification label 5 Removable terminal block (RTB) with finger-safe cover 5a RTB upper-retaining screw 5b RTB lower-retaining screw 6a Movable bus connector (bus interface) with female pins 6b Stationary bus connector (bus interface) with male pins 7 Nameplate label 8a Upper tongue-and-groove slots 8b Lower tongue-and-groove slots 9a Upper DIN-rail latch 9b Lower DIN-rail latch 10 Write-on label for user identification tags
7 Compact I/O High-speed Counter Module 7 Module Installation The 1769-HSC module is suitable for use in an industrial environment when installed in accordance with these instructions. Specifically, this equipment is intended for use in clean, dry environments (Pollution Degree 2 (1) ) and with circuits not exceeding Over Voltage Category II (2) (IEC ). (3) Removal and Insertion Under Power (RIUP) WARNING: When you insert or remove the module while backplane power is on, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding. Repeated electrical arcing causes excessive wear to contacts on both the module and its mating connector. Worn contacts may create electrical resistance that can affect module operation. Removable Terminal Block (RTB) Under Power WARNING: When you connect or disconnect the removable terminal block (RTB) with field side power applied, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding. Hazardous Location Enclosure WARNING: When used in a Class I, Division 2, hazardous location, this equipment must be mounted in a suitable enclosure with proper wiring method that complies with the governing electrical codes. (1) Pollution Degree 2 is an environment where, normally, only non-conductive pollution occurs except that occasionally a temporary conductivity caused by condensation shall be expected. (2) Over Voltage Category II is the load level section of the electrical distribution system. At this level transient voltages are controlled and do not exceed the impulse voltage capability of the product s insulation. (3) Pollution Degree 2 and Over Voltage Category II are International Electrotechnical Commission (IEC) designations.
8 8 Compact I/O High-speed Counter Module System Planning There are several factors to consider when planning your system: A 1769-ECR (right-end cap) or 1769-ECL (left-end cap) is required to terminate the end of the Compact I/O bus. Each bank of Compact I/O modules must have its own power supply. (A MicroLogix 1500 base unit acts as the power supply for modules directly connected to it.) The module has a distance rating of four, therefore the module must be within four modules of the I/O bank s power supply. A Compact I/O power supply, or MicroLogix 1500 base unit, has limits in the amount of 5V DC and 24V DC current that it can supply to modules in its I/O bank. These limits depend on the catalog number (for example, 1769-PA2) of the supply. A bank of modules must not exceed the current limits of the I/O bank power supply or MicroLogix 1500 base unit. Refer to these publications for more information: Compact I/O Expansion Power Supplies Installation Instructions, publication 1769-IN028 MicroLogix 1500 Programmable Controllers User Manual, publication 1764-UM001 System Assembly The module can be attached to an adjacent controller, power supply, or I/O module. For mounting instructions, see Panel Mounting on page 10, or DIN Rail Mounting on page 12. See Replacing a Single Module within a System on page 12 to work with a system that is already mounted.
9 Compact I/O High-speed Counter Module 9 Refer to the illustration when assembling the Compact I/O system. See page 6 for a description of the module. A D E C B B G F Disconnect the power. 2. Check that the bus lever of the module (A) is in the unlocked (fully right) position. 3. Use the upper and lower tongue-and-groove slots (B) to secure the modules together. 4. Move the module back along the tongue-and-groove slots until the bus connectors (C) line up with each other. 5. Use your fingers or a small screwdriver to push the bus lever back slightly to clear the positioning tab (D). 6. Move the module s bus lever fully to the left (E) until it clicks, making sure it s locked firmly in place. ATTENTION: When attaching I/O modules, it s very important that the bus connectors are securely locked together to provide proper electrical connection. 7. Attach an end cap terminator (F) to the last module in the system by using the tongue-and-groove slots. 8. Lock the end cap bus terminator (G). IMPORTANT A 1769-ECR or 1769-ECL right or left end cap must be used to terminate the end of the Compact I/O module.
10 10 Compact I/O High-speed Counter Module System Mounting ATTENTION: This product is intended to be mounted to a well-grounded mounting surface, such as a metal panel. Additional grounding connections from the power supply's mounting tabs or DIN rail (if used) are not required unless the mounting surface cannot be grounded. Refer to Industrial Automation Wiring and Grounding Guidelines, publication , for additional information. Minimum Spacing Maintain spacing from enclosure walls, wireways, adjacent equipment, and so forth. Allow 50 mm (2 in.) of space on all sides for adequate ventilation, as shown in the illustration. Side Controller Top Compact I/O Compact I/O Compact I/O Bottom Compact I/O Compact I/O End Cap or Cable Side Panel Mounting Mount the module to a panel by using two screws per module. Use M4 or #8 panhead screws. Mounting screws are required on every module. Figure 1 - Compact I/O Modules with CompactLogix Controller and Power Supply Mounting Hole Dimension 50 mm 35 mm 70 mm 35 mm (1.97 in.) (1.38 in.) (2.76 in.) (1.38 in.) 40 mm 35 mm 35 mm 35 mm 35 mm (1.58 in.) (1.38 in.) (1.38 in.)(1.38 in.) (1.38 in.) 28.5 mm (1.12 in.) mm (4.83 in.) 59 mm 59 mm (2.32 in.) (2.32 in.) 118 mm (4.65 in.) mm (5.81 in.) 132 mm (5.19 in.) DIN Rail Center Line 14.7 mm (0.58 in.) Important: Hole spacing tolerance: ±0.04 mm (0.016 in.)
11 Compact I/O High-speed Counter Module 11 Figure 2 - Compact I/O Modules with MicroLogix 1500 Base Unit and Processor Mounting Hole Dimension 168 mm (6.62 in.) 147 mm (5.79 in.) 35 mm (1.38 in.) 35 mm (1.38 in.) 28.5 mm (1.12 in.) mm (4.83 in.) 59 mm 59 mm (2.32 in.) (2.32 in.) 118 mm (4.65 in) mm (5.81 in.) 132 mm (5.19 in.) DIN Rail Center Line 13.5 mm (0.53 in.) 14.7 mm (0.58 in.) Important: Hole spacing tolerance: ±0.04 mm (0.016 in.) Panel Mounting Procedure by Using Modules as a Template This procedure lets you to use the assembled modules as a template for drilling holes in the panel. Due to module mounting hole tolerance, it is important to do these steps. 1. On a clean work surface, assemble no more than three modules. 2. Using the assembled modules as a template, carefully mark the center of all module-mounting holes on the panel. 3. Return the assembled modules to the clean work surface, including any previously mounted modules. 4. Drill and tap the mounting holes for the recommended M4 or #8 screw. 5. Place the modules back on the panel, and check for proper hole alignment. 6. Attach the modules to the panel using the mounting screws. 7. Repeat step 1 through step 6 for any remaining modules.
12 12 Compact I/O High-speed Counter Module DIN Rail Mounting The module can be mounted on the following DIN rails: EN x 7.5 mm (1.38 x 0.3 in.) EN x 15 mm (1.38 x 0.59 in.) ATTENTION: During panel or DIN-rail mounting of all devices, be sure that all debris (metal chips, wire strands, and so forth) is kept from falling into the module. Debris that falls into the module could cause damage on powerup. 1. Before mounting the controller on a DIN rail, close the DIN rail latches. 2. Press the DIN rail mounting area of the controller against the DIN rail. The latches will momentarily open and lock into place. Figure 3 - DIN Rail Mounting Dimensions B C A Dimension A B C Height 118 mm (4.65 in.) 59 mm (2.325 in.) 59 mm (2.325 in.) Replace the Module within a System The module can be replaced while the system is mounted to a panel (or DIN rail). 1. Remove power, referring to Warnings on page Remove terminal block or disconnect input and/or output wiring from the module. 3. Remove the upper and lower mounting screws from the module (or open the DIN latches by using a screwdriver). 4. On the module to be replaced and the right-side adjacent module (or end cap if the module is the last module in the bank), move the bus levers to the right (unlock) to disconnect the module from the adjacent modules. 5. Gently slide the disconnected module forward.
13 Compact I/O High-speed Counter Module 13 If you feel excessive resistance, make sure that you disconnected the module from the bus and that you removed both mounting screws (or opened the DIN latches). TIP It may be necessary to rock the module slightly from front to back to remove it, or, in a panel-mounted system, to loosen the screws of adjacent modules. 6. Before installing the replacement module, be sure that the bus lever on the right-side adjacent module is in the unlocked (fully right) position. 7. Slide the replacement module into the open slot. 8. Connect the modules together by locking (fully left) the bus levers on the replacement module and the right-side adjacent module or end cap. 9. Replace the mounting screws (or snap the module onto the DIN rail). 10. Replace the terminal block or connect input and output wiring to the module. Field Wiring Connections Consider these system wiring guidelines when wiring your system. General Guidelines Disconnect power to the module before wiring. This includes sensor power and 1769 bus power. Input and output channels are isolated from the 1769-Compact bus. Input channels are isolated from one another; output channels are not. Shielded cable is required for high-speed input signals A, B, and Z. Use individually shielded, twisted-pair cable (or the type recommended by the encoder manufacturer) for lengths up to 300 m (1000 ft). Group this module and other low voltage DC modules away from AC I/O or high voltage DC modules. Route field wiring away from any other wiring and as far as possible from sources of electrical noise, such as motors, transformers, contactors, and AC devices. Routing field wiring in a grounded conduit can reduce electrical noise. If field wiring must cross AC or power cables, make sure that they cross at right angles. Make sure the system is properly grounded.
14 14 Compact I/O High-speed Counter Module Grounding Guidelines This product is intended to be mounted to a well-grounded mounting surface, such as a metal panel. Additional grounding connections from the module s mounting tabs or DIN rail (if used) are required only when the mounting surface is non-conductive and cannot be grounded. Keep shield connection to ground as short as possible. Ground the shield drain wire at the 1769-HSC module s input end only. Refer to the Industrial Automation Wiring and Grounding Guidelines, publication , for additional installation requirements Terminal Block Guidelines For optimum accuracy, limit overall cable impedance by keeping cable as short as possible. Locate the module as close to input devices as the application permits. Tighten terminal screws with care. Excessive tightening can strip a screw. Wire Diagrams The following pages show wiring examples for a differential encoder, single-ended encoder, and discrete device. Figure 4 - Differential Encoder Wiring Cable (1) VS +VDC Power COM Supply GND A A1(+) A A1( ) Allen-Bradley 845H Series Differential Encoder B B Z Z Shield B1(+) B1( ) Z1(+) Z1( ) Shield/Housing Connect only if housing is electronically isolated from the motor and ground. Earth Module Inputs (1) Refer to your encoder manual for proper cable type. The type of cable used should be twisted-pair, individually shielded cable with a maximum length of 300 m (1000 ft).
15 Compact I/O High-speed Counter Module 15 Figure 5 - Single-Ended Encoder Wiring VS GND Cable (1) +VDC COM Power Supply R (2) A A1(+) A1( ) Allen-Bradley 845H Series Single-ended Encoder B Z Shield B1(+) B1( ) Z1(+) Z1( ) Shield/Housing Connect only if housing is electronically isolated from the motor and ground. Earth Module Inputs (1) Refer to your encoder manual for proper cable type. The type of cable used should be twisted-pair, individually shielded cable with a maximum length of 300 m (1000 ft). (2) External resistors are required if they are not internal to the encoder. The pull-up resistor (R) value depends on the power supply value. The table shows the maximum resistor values for typical supply voltages. To calculate the maximum resistor value, use the following formula: R= Imin where: R = maximum pull-up resistor value V DC = power supply voltage V min = 2.6V DC I min = 6.8 ma Power Supply Voltage (V DC) Pull-up Resistor Value (R), Max (1) 5V DC 12V DC 24V DC VDC Vmin 352 Ω 1382 Ω 3147 Ω (1) Resistance values may change, depending upon your application. The minimum resistor (R) value depends on the current sinking capability of the encoder. Refer to your encoder s documentation.
16 16 Compact I/O High-speed Counter Module Figure 6 - Discrete Device Wiring Proximity Sensor VS +VDC COM Power Supply OUT A1(+) COM A1( ) VS OUT Solid-state Switch R (1) VS OUT COM B1(+) B1( ) Z1(+) COM Z1( ) Photo-electric Sensor with Open Collector Sinking Output (1) External resistors are required if they are not internal to the sensor. The pull-up resistor (R) value depends on the power supply value. The table shows the maximum resistor values for typical supply voltages. To calculate the maximum resistor value, use the following formula: ( VDC Vmin) R= Imin where: R = maximum pull-up resistor value V DC = power supply voltage V min = 2.6V DC I min = 6.8 ma Power Supply Voltage (V DC) Pull-up Resistor Value (R), Max (1) 5V DC 12V DC 24V DC 352 Ω 1382 Ω 3147 Ω (1) Resistance values may change, depending upon your application. Module Inputs The minimum resistor (R) value depends on the current sinking capability of the sensor. Refer to your sensor s documentation.
17 Compact I/O High-speed Counter Module 17 Output Wiring Basic wiring (1) of output devices (2) to the module is shown in Figure 7. ATTENTION: Follow these guidelines: Miswiring of the module to an AC power source or applying reverse polarity will damage the module. Be careful when stripping wires. Wire fragments that fall into a module could cause damage at powerup. Once wiring is complete, be sure that the module is free of all metal fragments. Figure 7 - Output Device Wiring CR OUT 0 OUT 2 OUT DC COM AO- BO- ZO- A1- B!- Z1- OUT DC 5/24 V DC OUT 1 OUT 3 AO+ BO+ ZO+ A1+ B1+ Z1+ CR CR 5/24V DC +DC -DC Remove the Finger-safe Terminal Block When wiring field devices to the module, it is not necessary to remove the terminal block. If you remove the terminal block, use the write-on label on the side of the terminal block to identify the module slot location and type. SLOT # MODULE TYPE To remove the terminal block, loosen the upper and lower retaining screws. The terminal block will back away from the module as you remove the screws. When replacing the terminal block, torque the retaining screws to 0.46 N m (4.1 lb in). (1) Recommended Surge Suppression - The module has built-in suppression which is sufficient for most applications, however, for high-noise applications, use a 1N4004 diode reverse-wired across the load for transistor outputs switching 24V DC inductive loads. For additional details, refer to Industrial Automation Wiring and Grounding Guidelines, publication (2) Sourcing Output - Source describes the current flow between the I/O module and the field device. Sourcing output circuits supply (source) current to sinking field devices. Field devices connected to the negative side (DC Common) of the field power supply are sinking field devices. Field devices connected to the positive side (+V) of the field supply are sourcing field devices. Europe: DC sinking input and sourcing output module circuits are the commonly used options.
18 18 Compact I/O High-speed Counter Module Wire the Finger-safe Terminal Block When wiring the terminal block, keep the finger-safe cover in place. Upper Retaining Screw Wiring the Finger-safe Terminal Block Lower Retaining Screw 1. Loosen the terminal screws to be wired. 2. Route the wire under the terminal pressure plate. You can use the bare wire or a spade lug. The terminals accept a 6.35 mm (0.25 in.) spade lug. TIP The terminal screws are non-captive. Therefore, it s possible to use a ring lug (6.35 mm (0.25 in.) maximum outside diameter with 3.53 mm (0.139 in.) minimum inside diameter) with the module. 3. Tighten the terminal screw making sure the pressure plate secures the wire. Recommended torque when tightening terminal screws is 0.68 N m (6 lb in). TIP If you need to remove the finger-safe cover, insert a screwdriver into one of the square wiring holes and gently pry the cover off. If you wire the terminal block with the finger-safe cover removed, you will not be able to put it back on the terminal block because the wires will be in the way. Wire Size and Terminal Screw Torque Each terminal accepts up to two wires with these restrictions. Wire Type Wire Size Terminal Screw Torque Retaining Screw Torque Solid Cu-90 C (194 F) mm 2 ( AWG) 0.68 N m (6 lb in) 0.46 N m (4.1 lb in) Stranded Cu-90 C (194 F) mm 2 ( AWG) 0.68 N m (6 lb in) 0.46 N m (4.1 lb in)
19 Compact I/O High-speed Counter Module 19 Wire the Modules After the module is properly installed, wire the modules by using this procedure. To provide proper operation and high immunity to electrical noise, always use shielded wire. ATTENTION: To prevent shock hazard, care should be taken when wiring the module to signal sources. Before wiring any module, disconnect power from the system power supply and from any other source to the module. Do not wire more than two conductors on any single terminal. Cable Cut Foil Shield and Drain Wire Signal Wire Signal Wire Drain Wire Foil Shield Signal Wire Signal Wire Do these steps to wire your module. 1. At each end of the cable, strip some casing to expose the individual wires. 2. Trim the signal wires to 5 cm (2 in.) lengths, stripping about 5 mm (0.2 in.) of insulation away to expose the end of the wire. ATTENTION: Be careful when stripping wires. Wire fragments that fall into a module could cause damage at powerup. 3. At the 1769-HSC module s input end of the cable, twist the drain wire and foil shield together, bending them away from the cable, and apply shrink wrap, grounding the shield at this end by using as short a lead-length as possible. 4. At the other end of the cable, cut the drain wire and foil shield back to the cable and apply shrink wrap. 5. Connect the signal wires to the terminal block, connecting the other end of the cable to the input device. 6. Repeat step 1 through step 5 for each channel on the module.
20 20 Compact I/O High-speed Counter Module Output Operation The four output terminals must be powered by a user-supplied external source. User-power range is from 5 30V DC. See Output Specifications on page 27 for voltage and current levels. There is no isolation between the outputs, but the outputs are isolated from the inputs and the 1769 Compact bus. Electronic Protection The electronic protection of the 1769-HSC module has been designed to provide protection from current overload and short-circuit conditions. The protection is based on a thermal cut-out principle. In the event of a short circuit or current-overload condition on an output channel, that channel will turn off within milliseconds after the thermal cut-out temperature has been reached. When this occurs, the module s fuse status indicator will turn on. You have the option to allow the protection device to automatically reset, or to be reset under program control. The automatic reset function occurs after the thermal protection device cools. If the current overload or short-circuit condition still exists, the automatic reset cycle repeats until it is removed. TIP Correct short-circuit and overload conditions as soon as possible. If short-circuit and overload conditions occur for extended periods, damage can occur. Figure 8 - Timing Diagram for Over-current and/or Short-circuit Shutdown and Restart I L1 IN1 Other Channel: Normal Operation IN1 Commanded state of output channel I L1 Output current due to short-circuit overload I L(SCp) Peak short-circuit or overload current I L(SCp) t off(sc) I L(SCr) t off(sc) Time before shut-off occurs. This may take up to 11 ms depending on external conditions. I L(SCr) Recurring short-circuit or overload Under-voltage Condition If the field supply voltage falls below a value of approximately 4V DC, all of the 1769-HSC module s outputs shut down and remain off until the field supply voltage returns to a value within the module s normal operating range.
21 Compact I/O High-speed Counter Module 21 Transistor Output Transient Pulses The maximum duration of the transient pulse occurs when minimum load is connected to the output. However, for most applications, the energy of the transient pulse is not sufficient to energize the load. ATTENTION: A transient pulse occurs in transistor outputs when the external DC supply voltage is applied to the output common terminals (for example, via the master control relay). The sudden application of voltage creates this transient pulse. This condition is inherent in transistor outputs and is common to solid state devices. A transient pulse can occur regardless of the controller having power. Refer to your controller s user manual to reduce the chance of inadvertent operation. Figure 9 illustrates that the duration of the transient pulse is proportional to the load current. Therefore, as the on-state load current increases, the transient pulse decreases. Power-up transients do not exceed the time duration for the amount of loading indicated at 60 C (140 F). Figure 9 - Transient Pulse Duration as a Function of Load Current Time - Duration of Transient Pulse (ms) On-State Load Current (ma)
22 22 Compact I/O High-speed Counter Module Module Powerup At module powerup, a series of internal diagnostic tests are performed. These diagnostic tests must be successfully completed or the module OK status indicator remains off or red, and a module error is reported to the controller. Diagnostic Indicators OUT IN 0 2 FUSE 1 3 OK A0 A1 B0 B1 Z0 Z1 Status Indicator Color Indicates Status Indicator Color Indicates 0 OUT Amber ON/OFF logic status of output 0 A0 Amber ON/OFF status of input A0 1 OUT Amber ON/OFF logic status of output 1 A1 Amber ON/OFF status of input A1 2 OUT Amber ON/OFF logic status of output 2 B0 Amber ON/OFF status of input B0 3 OUT Amber ON/OFF logic status of output 3 B1 Amber ON/OFF status of input B1 FUSE Red Overcurrent Z0 Amber ON/OFF status of input Z0 OK Off No power is applied Z1 Amber ON/OFF status of input Z1 Red (briefly) Performing self-test Solid green Normal operating condition Flashing green OK, in Program or Fault mode ALL ON Solid red or amber Flashing red Hardware error. Cycle power to the module. If problem persists, replace the module Recoverable fault. Reconfigure, reset, or perform error recovery. Refer to the Compact I/O High-speed Counter User Manual, publication 1769-UM006 Possible causes for all status indicators to be On include the following: Bus error has occurred: Controller hard fault. Cycle power. During upgrade of controller: Normal. Do not cycle power during the upgrade. Default Configuration When the module is powered up for the first time, it uses the following default configuration values. All counters are disabled and all outputs are off. The module s Default Safe State configuration is all zero s, resulting in the following: Program State = UDSS (user-defined safe state) Program Value = OFF ProgramStateRun = No Fault State = UDSS (user-defined safe state) Fault Value = OFF FaultStateRun = No PFE (Program to Fault Enable) = leave program value applied. Refer to the Compact I/O High-speed Counter User Manual, publication 1769-UM006, and use your programming software to change the configuration.
23 Temperature Derating Compact I/O High-speed Counter Module 23 The following graphs indicate how much current can be drawn from the power supply at the indicated case temperature without damaging it. Maximum Input Voltage - 24V DC Operation Voltage Derating Based on Temperature 26.4V DC at 55 C (131 F) Volts (DC) (-32) (50) (68) (86) (104) (122) (140) (158) Ambient Temperature, C ( F) Temperature Derated Voltage (1) 0 40 C ( F) 30V DC 55 C (131 F) 26.4VDC 60 C (140 F) 5V DC (1) Input voltage derating between C ( F) is achieved by using a dropping resistor. For 24V DC input voltage, use a 2.4 kω, ½ W resistor. For input voltages other than 24V DC, use a ½ W resistor with value: 125 x (V in - 5V). Maximum Output Voltage - 24V DC Operation Voltage Derating Based on Temperature Volts (DC) 26.4V DC at 55 C (131 F) (-32) (50) (68) (86) (104) (122) (140) (158) Ambient Temperature, C ( F) Temperature Derated Voltage 0 40 C ( F) 30V DC C ( F) 26.4V DC
24 24 Compact I/O High-speed Counter Module Maximum Output Current per Point - 5V DC Operation Current Derating Based on Temperature Current per Point (A) 0.5 A at 60 C (140 F) (-32) (50) (68) (86) (104) (122) (140) (158) Ambient Temperature, C ( F) Temperature Derated Current 0 40 C ( F) 1 A 60 C (140 F) 0.5 A Maximum Output Current per Module - 5V DC Operation Current Derating Based on Temperature Current per Module (A) 2 A at 60 C (140 F) (-32) (50) (68) (86) (104) (122) (140) (158) Ambient Temperature, C ( F) Temperature Derated Current 0 40 C ( F) 4 A 60 C (140 F) 2.0 A
25 Compact I/O High-speed Counter Module 25 Maximum Output Current per Point - 24V DC Operation Current Derating Based on Temperature Current per Point (A) (-32) (50) (68) (86) (104) (122) (140) (158) Ambient Temperature, C ( F) 0.25 A at 60 C (140 F) Temperature Derated Current 0 40 C ( F) 1 A 55 C (131 F) 0.5 A 60 C (140 F) 0.25 A Maximum Output Current per Module - 24V DC Operation Current Derating Based on Temperature Current per Module (A) 1 A at 60 C (140 F) (-32) (50) (68) (86) (104) (122) (140) (158) Ambient Temperature, C ( F) Temperature Derated Current 0 40 C ( F) 4 A 55 C (131 F) 2 A 60 C (140 F) 1 A
26 26 Compact I/O High-speed Counter Module Specifications Technical Specifications HSC Attribute Dimensions (H x W x D), approx. Shipping weight (with carton), approx. Bus current draw, max Heat dissipation Isolation voltage All supply power and/or current ratings 1769-HSC 118 x 35 x 87 mm (4.65 x 1.38 x 3.43 in.) Height including mounting tabs is 138 mm (5.43 in.) 309 g (0.681 lb) 425 ma at 5V DC 0 ma at 24V DC 6.21 W The Watts per point, plus the minimum Watts, with all points energized 75V (continuous), reinforced insulation type, channel-to-system and channel-to-channel Type tested at 1200V AC for 2 s Input: 30 V DC, 40 C (104 F) Output: 1 A per channel, 4 A per module, 30 V DC, 40 C (104 F) Power supply distance rating Module cannot be more than four modules away from a system power supply Recommended cable Individually shielded, twisted-pair cable (or the type recommended by the encoder or sensor manufacturer) Wire size mm 2 (22 14 AWG) solid copper wire or mm 2 (22 16 AWG) stranded copper wire rated at 90 C (194 F ) insulation max Wiring category 2 - on signal ports (1) Vendor ID code 1 Product type code 109 Product code 19 Enclosure type rating None (open-style) North American temp code T3C (1) Use this Conductor Category information for planning conductor routing. Refer to the Industrial Automation Wiring and Grounding Guidelines, publication Input Specifications HSC Attribute 1769-HSC No. of inputs 2 quadrature (ABZ) differential inputs Input voltage range V DC (1) On-state voltage, max 30V DC (1)
27 Compact I/O High-speed Counter Module 27 Input Specifications HSC Attribute On-state voltage, min On-state current, min Off-state voltage, max Off-state current, max Off-state leakage current, max Input current, max Input current, min Input impedance, nom Pulse width, min Pulse separation, min Input frequency, max 1769-HSC 2.6V DC 6.8 ma 1.0V DC 1.5 ma 1.5 ma 15 ma 6.8 ma 1950 Ω 250 ns 131 ns 1 MHz (1) See Maximum Input Voltage - 24V DC Operation temperature derating on page 23. Output Specifications HSC Attribute 1769-HSC No. of outputs 16 total, 4 physical and 12 virtual Output voltage range 5 30V DC (1) On-state voltage, max User power - 0.1V DC On-state current, max 1 A per point (2) 4 A per module (3) On-state current, min 1 ma On-state voltage drop, max 0.5V DC Off-state leakage current, max 5 µa Turn-on time, max 400 µs (4) Turn-off time, max 200 µs Reverse polarity protection 30V DC (1) See Maximum Output Voltage - 24V DC Operation temperature derating on page 23. (2) See Maximum Output Current per Point - 5V DC Operation temperature derating on page 24 and Maximum Output Current per Point - 24V DC Operation temperature derating on page 25. (3) See Maximum Output Current per Module - 5V DC Operation temperature derating on page 24 and Maximum Output Current per Module - 24V DC Operation temperature derating on page 25. (4) Maximum turn-on time applies to an output voltage range of 5 7V DC. For output voltages greater than 7V DC, the maximum turn-on time is 200 µs.
28 28 Compact I/O High-speed Counter Module Environmental Specifications HSC Attribute Temperature, operating 1769-HSC 0 60 C ( F) IEC (Test Ad, Operating Cold), IEC (Test Bd, Operating Dry Heat), IEC (Test Nb, Operating Thermal Shock) Temperature, surrounding air, max Temperature, nonoperating 40 C (104 F) C ( F) IEC (Test Ab, Unpackaged Nonoperating Cold), IEC (Test Bb, Unpackaged Nonoperating Dry Heat), IEC (Test Na, Unpackaged Nonoperating Thermal Shock) Relative humidity % noncondensing IEC (Test Db, Unpackaged Damp Heat) Vibration, operating IEC (Test Fc, Operating) Vibration, relay operation Hz, peak-to-peak Hz (1) IEC Shock, operating IEC (Test Ea, Unpackaged Shock) Shock, nonoperating IEC (Test Ea, Unpackaged Shock) Emissions 30 g, 11 ms panel mounted 20 g, 11 ms DIN rail mounted 40 g, panel mounted 30 g, DIN rail mounted Group 1, Class A CISPR 11 ESD immunity IEC Radiated RF immunity IEC kv contact discharges 8 kv air discharges 10V/m with 1 khz sine-wave 80% AM from MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 and 1890 MHz 10V/m with 1 khz sine-wave 80% AM from MHz
29 Compact I/O High-speed Counter Module 29 Environmental Specifications HSC Attribute EFT/B immunity IEC Surge transient immunity IEC Conducted RF immunity IEC HSC ±2 kv at 5 khz on power ports ±2 kv at 5 khz on signal ports ±1 kv line-line (DM) and ±2 kv line-earth (CM) on power ports ±1 kv line-line (DM) and ±2 kv line-earth (CM) on signal ports ±1 kv line-earth (CM) on shielded ports 10V rms with 1 khz sine-wave 80% AM from 150 khz 80 MHz (1) This rating applies for your system if a relay module, such as the 1769-OW8, is used. Certifications HSC (1) Certification (2) c-ul-us c-ul-us CE C-Tick 1769-HSC UL Listed Industrial Control Equipment, certified for U.S. and Canada. See UL File E65584 UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E European Union 2004/108/EC EMC Directive, compliant with: EN ; Industrial Immunity EN ; Industrial Emissions EN ; Programmable Controllers (Clause 8, Zone A & B) Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions (1) When product is marked. (2) See the Product Certification link at for Declarations of Conformity, Certificates, and other certification details.
30 30 Compact I/O High-speed Counter Module Additional Resources These documents contain additional information concerning related Rockwell Automation products. Resource Compact High-speed Counter Module User Manual, publication 1769-UM006 ControlLogix System User Manual, publication 1756-UM001 MicroLogix 1500 Programmable Controllers User Manual, publication 1764-UM001. Industrial Automation Wiring and Grounding Guidelines, publication Product Certifications website, publication Description Detailed description of how to use your High-speed Counter Module. Detailed description of how to use your ControlLogix operating system. Information on how to use your MicroLogix 1500 system. More information on proper wiring and grounding techniques. Provides declarations of conformity, certificates, and other certification details. If you need more information on these products, contact your local Rockwell Automation distributor or sales office. The documentation listed in the Related Documentation table is available at
31 Compact I/O High-speed Counter Module 31 Notes:
32 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration and troubleshooting, we offer TechConnect support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit Installation Assistance If you experience a problem within the first 24 hours of installation, please review the information that's contained in this manual. You can also contact a special Customer Support number for initial help in getting your product up and running. United States or Canada Outside United States or Canada Use the Worldwide Locator at or contact your local Rockwell Automation representative. New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures. United States Outside United States Contact your distributor. You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process. Please contact your local Rockwell Automation representative for the return procedure. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at Allen-Bradley, Rockwell Software, Rockwell Automation, CompactLogix, MicroLogix, Compact I/O, ControlLogix, and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat: İçerenköy, İstanbul, Tel: +90 (216) Supersedes Publication 1769-IN030A-EN-P - December 2001 PN Copyright 2010 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Compact I/O End Caps/Terminators
Installation Instructions Compact I/O End Caps/Terminators Catalog Numbers 1769-ECL, 1769-ECR Topic Page Important User Information 2 Environment and Enclosure 3 North American Hazardous Location Approval
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
1756 ControlLogix Chassis Specifications
Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,
Installation Instructions. DeviceNet Modules. Catalog Numbers 1756-DNB, 1769-ADN, 1769-SDN
Installation Instructions DeviceNet Modules Catalog Numbers 1756-DNB, 1769-ADN, 1769-SDN Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical
MicroLogix 1762-IF4 Analog Input Module
Installation Instructions MicroLogix 1762-IF4 Analog Input Module Catalog Number 1762-IF4 Table of Contents Topic Page Important User Information 2 North American Hazardous Location Approval 4 Additional
USB-to-Data Highway Plus Cable
Installation Instructions USB-to-Data Highway Plus Cable Catalog Number 1784-U2DHP Topic Page Important User Information 2 Environment and Enclosure 3 Install the Cable 5 Configure the DH+ Node Address
Compact I/O Expansion Power Supplies
Compact I/O Expansion Power Supplies Installation Instructions Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4 Topic Page Important User Information 2 Environment and Enclosure 3 North American
Micro800 1.5" LCD Display and Keypad Module
Wiring Diagrams Micro800 1.5" LCD Display and Keypad Module Catalog Number 2080-LCD http://literature.rockwellautomation.com Cette publication est disponible en français sous forme électronique (fichier
POINT I/O Input Modules
Installation Instructions POINT I/O Input Modules Catalog numbers 734-IB, 734-IB4, 734-IB8, Series C Table of Contents Topic Page Important User Information Environment and Enclosure 3 Preventing Electrostatic
1788 Linking Device Specifications
Technical Data 1788 Linking Device Specifications Catalog Numbers 1788-EN2DNROM, 1788-EN2DNR, 1788-EN2FFR, 1788-EN2PAR, 1788-CN2DN, 1788-CN2FFR, 1788-CN2PAR, 1788-FBJB4R, 1788-FBJB6 Topic Page 1788-EN2DNR
Installation Instructions. FLEX I/O DeviceNet Adapter Module 1794-ADN Series C and 1794-ADNK Series C
FLEX I/O DeviceNet Adapter Module 1794-ADN Series C and 1794-ADNK Series C (Modules with a K in the last position of the catalog number are conformally coated to meet noxious gas requirements of ISA/ANSI-71.040
Micro810 USB Adapter. Wiring Diagrams. Catalog Number 2080-USBADAPTER
Wiring Diagrams Micro810 USB Adapter Catalog Number 2080-USBADAPTER http://literature.rockwellautomation.com Cette publication est disponible en français sous forme électronique (fichier PDF). FR Pour
FLEX I/O Digital Input Modules
Installation Instructions FLEX I/O Digital Input Modules Catalog numbers 1794-IB8, 1794-IB16, 1794-IB32 Table of Contents Topic Page Important User Information 2 Environment and Enclosure 3 Preventing
Compact I/O Thermocouple/mV Input Module. Catalog Numbers 1769-IT6 User Manual
Compact I/O Thermocouple/mV Input Module Catalog Numbers 1769-IT6 User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical
POINT I/O 8 Channel High Density Current Input Module
Installation Instructions POINT I/O 8 Channel High Density Current Input Module Catalog Number 1734-IE8C Topic Page Important User Information 2 Environment and Enclosure 3 Prevent Electrostatic Discharge
EtherNet/IP Modules. Installation Instructions
Installation Instructions EtherNet/IP Modules Catalog Numbers 1756-ENBT, 1756-EN2F, 1756-EN2T, 1756-EN2TR, 1756-EN2TXT, 1756-EN2TRXT, 1756-EN2TSC, 1756-EN3TR, 1756-EWEB, 1768-ENBT, 1768-EWEB Important
1756 ControlLogix Integrated Motion Modules Specifications
Technical Data 1756 ControlLogix Integrated Motion Modules Specifications SERCOS Motion Catalog Numbers 1756-M03SE, 1756-M08SE, 1756-M16SE, 1756-M08SEG Analog Motion Catalog Numbers 1756-M02AE, 1756-M02AS,
Backup Scanner Module
Backup Scanner Module Catalog Number 1747-BSN Installation Instructions 2 Backup Scanner Module Important User Information Because of the variety of uses for the products described in this publication,
SLC 500 Analog Input Module
Installation Instructions SLC 500 Analog Input Module (Catalog Number 1746NI8) Inside Important User Information... 2 For More Information... 3 Hazardous Location Considerations... 4 Environnements dangereux...
1756 ControlLogix Power Supplies Specifications
Technical Data 1756 ControlLogix Power Supplies Specifications Standard Power Supplies Catalog Numbers 1756-PA72, 1756-PA75, 1756-PB72, 1756-PB75, 1756-PC75, 1756-PH75 Standard Slim Power Supplies Catalog
POINT I/O EtherNet/IP Adapter
Installation Instructions POINT I/O EtherNet/IP Adapter Catalog Number 1734-AENT LED Indicators Safety End Cap Node Address Thumbwheel EtherNet Network RJ45 Connector DIN Rail Locking Screw (orange) RTB
1756 ControlLogix I/O Specifications
Technical Data 1756 ControlLogix I/O Specifications Catalog Numbers 1756 series Topic Page Additional Resources 1 Available 1756 I/O Modules 2 ControlLogix I/O Accessories 218 The ControlLogix architecture
SLC 500 Digital I/O Modules
Installation Instructions SLC 500 Digital I/O Modules Input Catalog Numbers 1746-IA4, 1746-IA8, 1746-IA16, 1746-IB8, 1746-IB16, 1746-IC16, 1746-IG16, 1746-IH16, 1746-IM4, 1746-IM8, 1746-IM16, 1746-IN16,
Allen-Bradley/Rockwell
MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:
Bimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
POINT I/O 24V dc Expansion Power Supply
nstallation nstructions PONT /O 4V dc xpansion Supply atalog Number 1734-P4D, Series nside... For See Page mportant User nformation Preventing lectrostatic Discharge 3 nvironment and nclosure 4 North American
Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P
Technical Data Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Topic Page 1609-P Specifications 2 1609-P Approximate Dimensions and Shipping Weights 3 Additional Resources
1769-L35E CompactLogix Controller
Installation Instructions 1769-L35E CompactLogix Controller (Catalog Numbers 1769-L35E) Inside... Before You Begin... 3 How to Handle CompactLogix Components... 3 Make Sure that You Have All the Components...
Universal Serial Bus (USB) to DH-485 Interface Converter
Installation Instructions Universal Serial Bus (USB) to DH-485 Interface Converter Catalog Number 1747-UIC Contents Overview..................................................3 Computer and Operating System
Hard Disk Drive (HDD)
Installation Instructions Hard Disk Drive (HDD) Catalog Number 6189V-35HDDST80, 6189V-35HDDST160 Topic Page About This Publication 1 Important User Information 2 Electrostatic Discharge (ESD) Precautions
Installation Instructions. Before Installation. Read these installation instructions carefully before commissioning the pressure transmitter.
Installation Instructions Differential Air-pressure Transmitter Catalog Numbers 1414-IPZ10FODAA, 1414-IPZ10FNDAA, 1414-IPD10FNRAA, 1414-CPZ10FODAA, 1414-CPZ10FNDAA, 1414-CPD10PNRAA Topic Page Before Installation
Installation Instructions. FLEX I/O Isolated Input Analog Module Cat. No. 1794-IF4I
nstallation nstructions FLEX /O solated nput Analog Module Cat. No. 1794-F4 mportant User nformation Solid state equipment has operational characteristics differing from those of electromechanical equipment.
1769-SDN DeviceNet Scanner Module. Catalog Numbers 1769-SDN User Manual
1769-SDN DeviceNet Scanner Module Catalog Numbers 1769-SDN User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment.
Molded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
Micro800 Programmable Controllers. Bulletin 2080 Selection Guide
Micro800 Programmable Controllers Bulletin 2080 Selection Guide Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade
Installation Instructions SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade Catalog Numbers 1747-DU501 Topic Page System Requirements 3 Install ControlFLASH 3 Prior to Running ControlFLASH
1769 Compact I/O Modules Specifications
Technical Data 1769 Compact I/O Modules Specifications Catalog Numbers 1769 Series Topic Page Summary of Changes 2 I/O Module Overview 2 Place Compact I/O Modules 4 Digital I/O Modules 4 Analog I/O Modules
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
ControlNet Standard and High-flex Coax Cable
Installation Instructions ControlNet Standard and High-flex Coax Cable Catalog Number 1786-RG6/A and 1786-RG6F/B About This Document This document contains application information you need to consider
Micro800 Programmable Controller Family. Bulletin 2080 Selection Guide
Micro800 Programmable Controller Family Bulletin 2080 Selection Guide Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment.
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
MicroLogix 1100 Programmable Controllers
Installation Instructions MicroLogix 1100 Programmable Controllers Catalog Numbers 1763-L16AWA, 1763-L16BWA, 1763-L16BBB, 1763-L16DWD Topic Page Important User Information 4 Additional Resources 5 Overview
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
STRATO LED Drivers 70W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
1769 CompactLogix Controllers User Manual
User Manual 1769 CompactLogix Controllers User Manual Catalog Numbers 1769-L31, 1769-L32C, 1769-L32E, 1769-L35CR, 1769-L35E Important User Information Solid-state equipment has operational characteristics
MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
Ethernet-to-DeviceNet Linking Device
Installation Instructions Ethernet-to-DeviceNet Linking Device Catalog Number 1788-EN2DN This publication tells you how to install the 1788-EN2DN Ethernet-to-DeviceNet linking device and use RSNetWorx
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit
PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives
MicroLogix 1400 Programmable Controllers
Installation Instructions MicroLogix 1400 Programmable Controllers Catalog Number(s) 1766-L32AWA, 1766-L32AWAA, 1766-L32BWA, 1766-L32BWAA, 1766-L32BXB, 1766-L32BXBA Topic Page Important User Information
UniStream CPU-for-Panel
UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic
XM-160/161/162 Direct Vibration Module
XM-160/161/162 Direct Vibration Module User Guide Firmware Revision 5 1440-VDRS06-00RH, 1440-VDRS06-06RH, 1440-VDRP06-00RH Important User Information Solid state equipment has operational characteristics
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Micro830 10 Point Programmable Controllers
Installation Instructions Micro830 10 Point Programmable Controllers Catalog Numbers 2080-LC30-10QWB, 2080-LC30-10QVB http://rockwellautomation.com/literature Cette publication est disponible en français
ST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
PanelView Component Specifications
Technical Data PanelView Component Specifications Catalog Numbers 2711C-F2M, 2711C-K2M, 2711C-T3M, 2711C-K3M, 2711C-T4T, 2711C-T6M, 2711C-T6T, 2711C-T10C Topic Page Environmental Specifications 2 General
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Analog Servo Drive 25A8
Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit
PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V
PHOTOVOLTAIC SYSTEM CONTROLLERS OPERATOR S MANUAL SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V 6A / 12V 10A / 12V 10A / 24V 20A / 12V 20A
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
DLP-PU/E Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
C13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19
C13 C13 Document ID: 2CMC486004M0201 2013-06-19 Disclaimer Copyrights Trademarks Contact The information in this document is subject to change without notice and should not be construed as a commitment
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
Application Technique. Safety Function: Magnetic Door Switch Monitoring
Application Technique Safety Function: Magnetic Door Switch Monitoring Products: MC1 Magnetically-coded Door Switch, Guardmaster Dual-input Safety Relay Safety Rating: CAT. 3, PLd to EN ISO 13849-1: 2008
CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number: 900-4602-0000
Electrical Specification for: CPCI-3U-AC-300W-R Rugged 300W AC Input 3U CompactPCI Power Supply Telkoor Part Number: 900-4602-0000 GENERAL SCALE RELEASE DATE 12/9/06 SHEET 1 OF 6 REVISION HISTORY Rev Level
Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.
Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
ABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
AutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
