MICROCABLES. A complete vision of your connectivity needs. Catalogue



Similar documents
Communication, Signal & Data Cables

rue E. Delacroix / BP 1 F Draveil cedex FRANCE Tel : Fax : Issue 2 01/10/

Broadcast and Commercial AV Cabling MASTER CATALOG

Standard Buccaneer - Ethernet

MacArtney Underwater Cables - In stock

COAX Cables Radio Frequency Cables

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

Cables and Accessories Selection Guide

RF cables. Edition 2015

6000 Series Buccaneer

ETHERLINE Ethernet Cable, Connectors & Tools

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

Gulf Cable & Electrical Ind. Co.

I-PEX MHF4 Micro Coaxial Connector

Specification SFTP CAT6 Network Cable 23AWG CU

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

TECHNICAL SPECIFICATION

LIFE-LINE Safety Cables Continuous Bending Hi-Flex Electrical Cables to Guarantee Safe Cable & Hose Carrier Systems

CONFLEX ELECTRIC CABLE

Table of Contents. Industrial/ Reference Hook-up Flat Ribbon Cable High Speed Cable. Registered to ISO 9001: REACHCompliant

RGB Component Video Cable Bundled RGB Coaxial Cables Miniature and High-Flex Type

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

Times Microwave Systems Hermetically Sealed Assemblies

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

Global cable expertise for rolling stock

Coaxial Cables for Medium-Frequency Applications

Analog Multi-Pair Snake Cable High-Flex and NEC Rated Cables

Uniprise Solutions COAX 101. White Paper.

CABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

Outside Telephone Cable

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

RF & Microwave cable assemblies C291

Standards Affecting a Premise T-1 Installation

C 060 CCTV Coaxial Cable

COAXICON Contacts. RF Coax Connectors. Product Facts

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

Standard Wire & Cable Co.

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

Bare copper complying with CEI EN (CEI 20-29) class 1. Foam PE with HDPE skin. Core colours: green and red

db MISER ULTRA LOW LOSS CABLE ASSEMBLIES Are you a design or test engineer fighting a challenging loss budget?

Sunridge MCB Series Miniature Coaxial Interconnect, 2.5mm or 2.0mm Mated Height

Basic Cable Assemblies DELIVERING QUALITY SINCE 1952.

RADOX railway cables acc. to EN and EN Edition 2009

3M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series

Directory chapter 04

Ultra Small Surface Mount Coaxial Connectors - 1.9mm or 2.4mm Mated Height

400 Series - Mini USB Buccaneer

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY

E Series. E Series. Category 6 and 5e. Features

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

UNITRONIC Data Communication Systems

Design Techniques for High Power RF Coaxial Cable Assemblies

Flexible Control Cables

Microphone and Musical Instrument Cable Overview

STANDARD MICRO-D CONNECTORS

KNOW YOUR OPTIONS: 230 KV POWER CABLES

Commercial Coaxial Cable

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

Fire Resistant Cables

CONTENT. Robot cables NEW. page. < The company < W - worldwide < Clientele / supplier numbers < Cables for dress package...

Instrumentation Cable Power Cable Assembly Solutions...32

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES

3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series

Standard Buccaneer - USB

Section kv Power Cables

Cables. Accessories. For Force, Torque and Strain Sensors

SPEC 55. Wire and cable. Applications. SPEC 55PC wire and cable insulation system. Features and benefits. Physical characteristics

ULTIMATE SNAP-N-SEAL

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

08. SEK IDC CONNECTORS

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras

ALARMLINE ANALOGUE Linear Heat Detection System

VIPERFLEX ELECTRIC CABLE

APR 2016 Rev M

75 Ω Transmission System

2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com

UTP Video Cables. Pair 2 - Category 5E Type 100Ω. The first pair is used for video transmission.

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

Serial Data Grade Cables

LOW LOSS CABLE PAG. 1

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

Precision Video Cable for Analog and Digital Overview

coaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable

Table of contents. Page. General information. Why BUS Systems? Field BUS DESINA. Bus Types and Sensor Bus. AS-Interface Bus 1. Interbus 3.

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

PTC-Resistor Temperature-Sensors MINIKA to DIN and DIN

ISO VIEW OF AX SERIES XLR CABLE CONNECTOR

EMC Test Chamber Solutions RF Cable Assemblies and Connectors

CONTENT. Robot cables. page. < The company < W - worldwide < Certifications < Clientele / supplier numbers... 6

Transcription:

MICROCABLES A complete vision of your connectivity needs Catalogue

ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics applications for miniaturization, reliability, performance, flexibility, higher density and EMI protection. From Medical to Instrumentation, Computers to Automated Test Equipment, Nexans offers solutions for the most demanding electronics applications. From 32 to 46 AWG, using high strength alloys and extruded fluorine resins insulation, in flat or round constructions, our development and design engineers are at your disposal to provide their experience in tailoring any of our products to meet your precise requirements. Electronics: - cables for instrumentation and test equipment applications (rack bus, positioning sensor, logic analysers, ); - cables for internal equipment or device-to-device connections. Computer and audio/video appliances (CD ROMto-Laptop connection, LCD panels protection, DVD connections,...). Ultrasound (external or internal applications for OB/Gyn, cardiology, veterinary, imaging applications, ). CCD cameras applications (CCD cameras for medical, industrial, endoscopy and videosurveillance applications). Other medical: Cardiac monitoring, pace makers, ECG/EKG, Issue 1 - November 2000-2 -

ELECTRONIC Filotex Advantages Wide range of conductors and dielectric materials; Construction Unique patented extrusion technology for low capacitance cables; Ultra-flexible cables; High speed transmission cable; Space and weight saving; High electrical performances (e r up to 1.5) Various styles available; Good physical properties (different jacket material for mechanical, chemical and climatic requirements). Single wires or coaxial cables assembled in a variety of constructions. Screened or unscreened wires available. Nexans designs round cable consisting of up to 528 elements and featuring an extremely small overall diameter of 13.0 mm/0.51. The microcables product line includes coaxial cables with an OD as small as 0.19mm/.007. Hook-up wires Singlecore unscreened from AWG 46 to AWG 32 Singlecore screened and jacketed from AWG 46 to AWG 32 Multicore and coaxial cables From 2 to 528 conductors From AWG 46 to AWG 32 inner conductor Unscreened and jacketed or screened and jacketed Composite cables Assembly of quads, pairs, coaxial Issue 1 - November 2000-3 -

ELECTRONIC Filotex Technology Inner conductor: silver plated alloy, stainless steel, silver plated copper (stranded or not) Main characteristics Insulation: FEP, PFA, PE (plain or special melt extrusion) Assembly: PTFE tape Drain wire*: silver plated alloy, silver plated copper Mechanical support*: aramid strength member in option Elect. Protection: polyester/aluminium tape, silver plated copper or alloy screen, tin plated copper screen or stainless steel screen Jacket: FEP, PFA, PVC, PUR, PE, TPE, PA * Optional Impedance : 50 W to 130 W Capacitance : 27 pf/m to 110 pf/m (8 pf/ft to 33pF/ft) Operating voltage : from 24 V to 250 V Operating temperature : from 60 C to +200 C Issue 1 - November 2000-4 -

ELECTRONIC Filotex Summary Part 1 Part 2 Part 3 Part 4 Part 5 Part 6 Microcables for all markets: single coaxials - Normal capacitance: 95pF/m - Low capacitance: 55pF/m Microcables for electronic application Microcables for computer application Microcables for ultrasound Microcables for CCD cameras applications - Microcables for Endoscopy - Microcables for Dental application Microcables for other medical applications - Microcables for catheter - Microcables for patient monitoring (invasive applications) - Microcables for ECG - Temporary myocard pacing wire Page 6 Page 7 Page 14 Page 16 Page 20 Page 23 Page 34 Page 35 Page 42 Page 47 Page 48 Page 51 Page 53 Page 55 Issue 1 - November 2000-5 -

Part 1 Microcables for all markets: single coaxials Issue 1 - November 2000-6 -

Normal capacitance 95pF/m All cables are also available in solid conductor version. Issue 1 - November 2000-7 -

Filotex STUDY 123836 32 AWG coax cable Micro coaxial cable Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. FILOTEX Ref : ET 123 836 1 2 3 Multi coax 95 pf/m AWG 32 stranded silver plated alloy. FEP insulation =.65 ±.02mm 44 AWG silver plated copper Helicoidal screen =.75mm nominal 4 FEP jacket =.91 ±.03mm Ultrasound cable assemblies. Characteristic impedance : 50 Ω nominal Linear capacitance : 95 ± 10 pf/m (29pF/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen :350 V DC 1 mn Operating temperature : - 50 C to + 200 C Minimum bending radius : 5 x Overall diameter. Standard colours Dielectric : Black Brown - Red - Orange - Yellow - Green - Blue - Violet - Grey - White Translucide Jacket : White 1 2 3 4 Issue 1 - November 2000-8 -

Filotex STUDY 132474 34 AWG coax cable Micro coaxial cable Very flexible cable with an extremely good mechanical behaviour. FILOTEX Ref : ET 132 474 Multi coax 95 pf/m 1 34 AWG(7 x.06 mm) stranded silver plated copper 2 PFA insulation =.53 ±.02mm 3 44 AWG silver plated copper braid Helicoidal screen =.75mm nominal 4 PFA jacket =.85 ±.03 mm Ultrasound cable assemblies. Characteristic impedance : 50 Ω nominal Linear capacitance : 95 ± 10 pf/m (29pF/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen :350 V DC 1 mn Operating temperature : - 50 C to + 200 C Minimum bending radius : 5 x Overall diameter. Standard colours Dielectric : Green Jacket : Black - Brown - Red - Orange Yellow - Green - Blue - Violet - Grey - White Translucide Issue 1 - November 2000-9 -

Filotex STUDY 124954 36 AWG coax cable Micro coaxial cable FILOTEX Ref : ET 124 954 1 2 3 Multi coax 95 Pf/M AWG 36 stranded silver plated copper. FEP insulation =.44 ± 02mm 44 AWG silver plated copper Helicoidal screen =.54mm nominal 4 FEP jacket =.63 ±.03 mm Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Ultrasound cable assemblies. Characteristic impedance : 50 Ω nominal Linear capacitance : 95 ± 10 pf/m (29pF/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn Operating temperature : - 50 C to + 200 C Minimum bending radius : 5 x Overall diameter. Standard colours Dielectric : Red or Green Jacket : Black - Brown - Red - Orange - Yellow - Green - Blue - Violet - Grey - White - Translucide 1 2 3 4 Issue 1 - November 2000-10 -

Filotex STUDY 122882 38 AWG coax cable Micro coaxial cable FILOTEX Ref : ET 122 882 Multi coax 95pF/m 1 AWG 38 stranded silver plated alloy 2 FEP insulation =.34 ±.02mm 3 44 AWG silver plated copper Helicoidal screen = 44mm nominal 4 FEP jacket =.53 ±.02mm Very flexible cable with an extremely good mechanical behaviour Withstands miscellaneous sterilisation processes Ultrasound cable assemblies Characteristic impedance : 50 Ω nominal Linear capacitance : 95 ± 10 pf/m (29pF/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn Operating temperature : - 50 C to + 200 C Minimum bending radius : 5 x Overall diameter. Standard colors Dielectric : Red or Green Jacket : Black - Brown - Red - Orange - Yellow - Green - Blue - Violet - Gray - White - Translucide 1 2 3 4 Issue 1 - November 2000-11 -

Filotex STUDY 132469 40 AWG coax cable Micro coaxial cable Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. FILOTEX Ref : ET 132 469 Multi coax 95 pf/m 1 AWG 40 silver plated alloy 135 wire 2 PFA insulation. =.23 ± 02mm 3 48 AWG silver plated copper Helicoidal screen =.29mm nominal 4 PFA jacket =.36 ±.03 mm Ultrasound cable assemblies. Characteristic impedance : 50 Ω nominal Linear capacitance : 95 ± 10 pf/m (29pF/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen :350 V DC 1 mn Operating temperature : - 50 C to + 200 C Minimum bending radius : 5 x Overall diameter. Standard colours Dielectric : Green Jacket : Black - Brown - Red - Orange Yellow - Green - Blue - Violet - Grey - White Translucide 1 2 3 4 Issue 1 - November 2000-12 -

Filotex STUDY 132358 42 AWG coax cable Micro coaxial cable Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. FILOTEX Ref : ET 132 358 Multi coax 95 pf/m 1 AWG 42 stranded silver plated alloy 2 PFA insulation =.21mm 3 48 AWG silver plated copper Helicoidal screen =.27mm nominal 4 FEP jacket =.35 ±.03 mm Ultrasound cable assemblies. Characteristic impedance : 50 Ω nominal Linear capacitance : 95 ± 10 pf/m (29pF/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen :350 V DC 1 mn Operating temperature : - 50 C to + 200 C Minimum bending radius : 5 x Overall diameter. Standard colours Dielectric : Green Jacket : Black - Brown - Red - Orange - Yellow - Green - Blue - Violet - Grey - White - Translucide 1 2 3 4 Issue 1 - November 2000-13 -

Low capacitance 55pF/m All cables are also available in solid conductor version. Issue 1 - November 2000-14 -

Filotex STUDY 132475 40 AWG coax cable Micro coaxial cable Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. FILOTEX Ref : ET 132 475 Multi coax 55 pf/m 1 AWG 40 silver plated alloy 135 wire 2 PFA SE insulation =.36 ±.02mm 3 48 AWG silver plated copper Helicoidal screen =.42mm nominal 4 PFA jacket =.47 ±.03 mm Ultrasound cable assemblies. Characteristic impedance : 80 Ω nominal Linear capacitance : 55 ± 5 pf/m (at 95%)(17pF/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn Max DC resistance : 1.2 Ω/ft Operating temperature : - 50 C to + 200 C Minimum bending radius : 5 x Overall diameter. Standard colours Dielectric : Red Jacket : Black - Brown - Red - Orange Yellow - Green Blue - Violet Grey - White Translucide 1 2 3 4 Issue 1 - November 2000-15 -

Part 2 Microcables for electronic application Linear capacitance : ET 132211 27pF/m ET 132084 33pF/m ET 124810 55pF/m Issue 1 - November 2000-16 -

Filotex STUDY 132211 41 AWG coax cable Cable for electronic application Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. FILOTEX Ref : ET 132 211 1 2 3 Coax 130 W AWG 41 constantan FEP SE insulation =.95 ±.05mm 44 AWG silver plated copper Helicoidal screen = 1.05mm nominal 4 PVC jacket = 1.40mm max Characteristic impedance : 130 ± 10 Ω Max linear capacitance : 27 pf/m (8 pf/ft) DC resistance : 130 ± 8 Ω/m Continuous operating voltage : 30 V eff. Test voltage between core and screen :350 V DC 1 mn Operating temperature : - 50 C to + 80 C Minimum bending radius : 5 x Overall diameter. Standard colours Dielectric : Yellow Jacket : Flint Grey 1 2 3 4 Issue 1 - November 2000-17 -

Filotex STUDY 132084 41 AWG coax cable Cable for electronic application Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. FILOTEX Ref : ET 132 084 1 2 3 4 Coax 130 W AWG 41constantan FEP SE insulation =.70 ±.03mm 44 AWG silver plated copper Helicoidal screen =.80mm nominal PVC jacket = 1.1 ±.05mm Characteristic impedance : 130 ± 10 Ω Linear capacitance : 33 ± 3 pf/m (10pF/ft) DC resistance : 130 ± 8 Ω/m Continuous operating voltage : 30 V eff. Test voltage between core and screen :350 V DC 1 mn Operating temperature : - 50 C to + 80 C Minimum bending radius : 5 x Overall diameter. Standard colours Dielectric : Red Jacket :Flint Grey 1 2 3 4 Issue 1 - November 2000-18 -

Filotex STUDY 124810 4 channels 38 AWG coax cable Cable for electronic application FILOTEX Ref : ET 124 810 Multi coax 55 pf/m 1 Core A : AWG 38 stranded silver plated alloy. FEP insulation =.51 ± 02mm AWG 48 silver plated copper Helicoidal screen =.57mm nominal FEP jacket =.62 ± 02mm 4 Cores A twisted = 1.5mm 2 PTFE = 1.55mm nominal tape 3 AWG 41 tin plated copper braid 90 % coverage = 1.8mm nominal 4 Medical P.V.C = 2.8 ±.15mm Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Cable for displacement sensor. Characteristic impedance : 80 Ω nominal Linear capacitance : 55 ± 5 pf/m (at 95%).(17pF/ft) Current capacity : > 250 ma Continuous operating voltage : 250 V DC. Operating temperature : - 20 C to + 75 C Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-19 -

Part 3 Microcables for computer application Linear capacitance : ET 132433 55 pf/m ET 132167 100 pf/m Issue 1 - November 2000-20 -

Filotex STUDY 132433 49 channels 42 AWG coax cable + 8 x 28 AWG wires Cable for computer application (input/output) Very flexible cable with an extremely good mechanical behaviour. FILOTEX Ref : ET 132 433 Multi coax 55 pf/m 1 Core A : AWG 42 (1 x 0.064 mm) silver plated Alloy. PFA " SE " insulation =.26 ±.02mm AWG 48 silver plated copper Helicoidal screen =.32 mm nominal PFA jacket =.36 ±.02mm 2 Core B : AWG 28 (7 x 0.13 mm) stranded tin plated copper. PFA insulation =.59 ±.03 mm 3 Core C : 8 Cores A twisted = 1.1 mm 4 Core D : 9 Cores A twisted = 1.3 mm 5 cores (C) + 1 cores (D) + 8 cores (B) twisted = 4.0 mm nominal 5 PTFE tape = 4.06 mm nominal. 6 AWG 40 tin plated copper braid 85 % coverage = 4.40 mm nominal 7 PVC jacket = 5.9 ±.2 mm Characteristic impedance cores A : 80 Ω nominal Linear capacitance cores A : 55 ± 5 pf/m (at 95%).(17 pf/ft) DC resistance cores A : <= 7.8 Ω/m (2.5 Ω/ft) Continuous operating voltage cores A : 24 V eff. Continuous operating voltage cores B : 250 V DC DC resistance cores B : <=.25 Ω/m (.076 Ω/ft) Test voltage between core and screen : 350 V DC 1 mn Insulation resistance : > 1000 MΩ.km Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-21 -

C Filotex STUDY 132167 49 channels 42 AWG coax cable + 8 x 28 AWG wires Cable for computer application (input/output) FILOTEX Ref : ET 132 167 Multi coax 100 pf/m 1 Core A : AWG 42 (1 x 0.064 mm) silver plated Copper. FEP insulation =.19 ±.02mm AWG 48 tin plated copper Helicoidal screen =.25mm nominal FEP jacket =.30 ±.02mm 2 Core B : AWG 28 (7 x 0.13 mm) stranded tin plated copper. FEP insulation =.59 ±.03mm 3 Core C : 8 Cores A twisted = 0.9mm 4 Core D : 9 Cores A twisted = 1.1mm 5 cores (C) + 1 cores (D) + 8 cores B twisted = 3.75mm nominal 5 PTFE tape = 3.8mm nominal. 6 AWG 40 tin plated copper braid 85 % coverage = 4.15mm nominal 7 PVC jacket = 5.5 ±.2mm Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Characteristic impedance cores A : 50 Ω nominal Linear capacitance cores A : 100 ± 10 pf/m (at 95%).(30.5pF/ft) DC resistance cores A : <= 7.8 Ω/m Continuous operating voltage cores A : 24 V eff. Continuous operating voltage cores B : 250 V DC DC resistance cores B : <=.25 Ω/m Test voltage between core and screen : 350 V DC 1 mn Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-22 -

Part 4 Microcables for Ultrasound : Veterinary application (mechanical probes) Transvaginal application Endocavity application Issue 1 - November 2000-23 -

Filotex STUDY 124311 11 channels 34 AWG coax + 8 x 26 AWG wires Medical Ultrasound cable FILOTEX Ref : ET 124 311 Ultra sound cable 1 Core A : AWG 34 stranded silver plated alloy. PTFE insulation =.52 ±.02mm AWG 43 silver plated copper braid FEP jacket = 1.02 ±.05 mm 2 Core B : AWG 26 stranded tin plated copper. PVC insulation 3 4 5 6 7 =.90 ±.10mm Fillers 7 cores (A) + 1 filler twisted AWG 40 tin plated copper helicoidal screen 90 % coverage 4 cores (A) + 8 cores (B) + fillers twisted around PTFE tape AWG 40 tin plated copper braid 95 % coverage Medical PVC = 7.45 ±3mm Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Ultrasound cable assemblies. Characteristic impedance core (A) : 50 nominal Linear capacitance core (A) : 95 ± 10 pf/m (at 95%).(29 pf/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-24 -

Filotex STUDY 124973 26 channels 36 AWG coax cable + 20 wires 30 AWG Medical Ultrasound cable FILOTEX Ref : ET 124 973 Multi coax 95 pf/m 1 Core A : AWG 36 stranded silver plated copper. FEP insulation =.44 ±.03mm AWG 44 silver plated copper Helicoidal screen =.54mm nominal FEP jacket =.63 ±.03 mm 2 Core B: AWG 30 stranded silver plated copper. FEP insulation =.5 ± 1mm 3 Core C: 3 cores A twisted 4 Core D: 4 cores B twisted 5 Core E: 3 cores B twisted 6 Core F: 2 cores A + 1 core B twisted 8 Cores (C) + 4 cores D + 1 core E + 1 core F twisted = 5.2 mm nominal 7 PTFE tape = 5.25 mm nominal. 8 AWG 40 tin plated copper braid 85 % coverage = 5.6mm nominal 9 Medical PVC = 7.0 ±.3mm Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Ultrasound cable assemblies. Characteristic impedance core (A) : 50 nominal Linear capacitance core (A) : 95 ± 10 pf/m (at 95%).(29 pf/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn DC resistance core (A) : 1.5 Ω/m DC resistance core (B) :.4 Ω/m Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-25 -

Filotex STUDY 124733 33 channels 40 AWG coax + 12 x 36 AWG wires Medical Ultrasound cable FILOTEX Ref : ET 124 733 Ultrasound cable 1 Core A : AWG 40 stranded silver plated alloy. FEP insulation =.25 ±.02 mm AWG 48 silver plated copper Helicoidal screen =.31 mm nominal FEP jacket =.39 ±.02 mm 2 Core B : AWG 36 stranded silver plated. FEP insulation =.40 ±.02mm 3 Core (C) 7 cores (A) twisted 4 Core (D) 6 cores (B) +Cotton filler twisted 5 Core (E) 5 cores (A) +Cotton filler twisted 4 Cores (C) + 2 cores (D) + 1 core (E) twisted = 3.50 mm nominal 6 PTFE tape = 3.7 mm nominal. 7 AWG 44 tin plated copper braid 85 % coverage = 3.9 mm nominal 8 Medical PVC = 4.9 ±.1mm Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Ultrasound cable assemblies. Characteristic impedance core (A) : 50 Ω nominal Linear capacitance core (A) : 95 ± 10 pf/m (at 95%).(29 pf/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-26 -

Filotex STUDY 123992 66 channels 38 AWG coax cable FILOTEX Ref : ET 123 992 Multi coax 95 pf/m 1 Core A : AWG 38 stranded silver plated alloy. FEP insulation =.34 ±.02mm AWG 44 silver plated copper Helicoidal screen =.44mm nominal FEP jacket =.53 ±.02mm 2 Core B : 8 Cores A twisted = 1.6mm 3 Core C : 2 Cores A twisted = 1.05mm 8 cores (B) + 1 cores (C) twisted = 5.3mm nominal 4 PTFE tape 5 = 5.35mm nominal. AWG 40 tin plated copper braid.85 % coverage = 5.7mm nominal 6 Medical P.V.C = 8 ±.2mm Medical Ultrasound cable Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Ultrasound cable assemblies. Characteristic impedance : 50 nominal Linear capacitance : 95 ± 10 pf/m (at 95%).(29pF/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-27 -

Filotex STUDY 124480 84 channels 38 AWG coax cable Medical Ultrasound cable FILOTEX Ref : ET 124 480 Multi coax 95 pf/m 1 Core A : AWG 38 stranded silver plated alloy. FEP insulation =.34 ±.02mm AWG 44 silver plated copper Helicoidal screen = 44mm nominal FEP jacket =.53 ±.02mm 2 Core B : 8 Cores A twisted = 1.6mm 3 Core C : 2 Cores A twisted = 1.05mm 10 cores (B) + 2 cores (C) twisted = 6.0mm nominal 4 PTFE tape = 6.05 mm nominal. 5 AWG 40 tin plated copper braid 85 % coverage = 6.4mm nominal 6 Medical P.V.C = 8.0 ±.2mm Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Ultrasound cable assemblies. Characteristic impedance : 50 nominal Linear capacitance : 95 ± 10 pf/m (at 95%).(29pF/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Flex life test : Standard test in accordance with drawing 250,000 cycles minimum Mover rollers 80 mm Moving range : 550 mm Cable length : 1600 mm Speed :.22 m/s (8 cycles/mn) Test weight (M) : 3000 g Issue 1 - November 2000-28 -

Filotex STUDY 124499 132 channels 38 AWG coax cable Medical Ultrasound cable FILOTEX Ref : ET 124 499 Multi coax 95 pf/m 1 Core A : AWG 38 silver plated copper wire. FEP insulation =.30 ±.02mm AWG 48 silver plated copper Helicoidal screen =.36mm nominal FEP jacket =.46 ±.02mm 2 Core B : 4 Cores A twisted = 1.1mm 3 Core C : 8 Cores A twisted = 1.4mm 1 cores (B) + 16 cores (C) twisted = 6.5mm nominal 4 PTFE tape = 6.6mm nominal. 5 AWG 41 tin plated copper braid 85 % coverage = 7.0mm nominal Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Ultrasound cable assemblies. Characteristic impedance : 50 Ω nominal Linear capacitance : 95 ± 10 pf/m (at 95%).(29pF/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-29 -

Filotex STUDY 132029 132 channels 40 AWG coax cable Medical Ultrasound cable FILOTEX Ref : ET 132 029 Multi coax 55pF/m 1 Core A : AWG 40 stranded silver plated alloy PD 135. FEP «SE» insulation =.34 ±.03 mm AWG 48 silver plated copper Helicoidal screen =.40mm nominal FEP jacket =.46 ±.03mm 2 Core B : 4 Cores A + Kevlar member tensile strength 50 kgf twisted = 1.15mm 3 Core C : 8 Cores A twisted = 1.5mm 1 core (B) + 16 cores C 4 5 6 twisted =6.3mm nominal PTFE tape = 6.35 mm nominal. AWG 40 silver plated alloy braid 85 % coverage = 6.7mm nominal Medical P.V.C = 8.5 ±.25mm Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Ultrasound cable assemblies. Characteristic impedance : 80 Ω nominal Linear capacitance : 55 ± 5 pf/m (at 95%).(17pF/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V AC 1 mn Max DC resistance of centre conductor : 1.2 Ω/ft Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-30 -

Filotex STUDY 124590 132 channels 42 AWG coax cable FILOTEX Ref : ET 124 590 Multicoax 95 pf/m 1 Core A : AWG 42 silver plated copper wire. FEP insulation =.20 ±.02 mm AWG 48 silver plated copper Helicoidal screen =.26 mm nominal FEP jacket =.34 ±.02 mm 2 Core B : 4 Cores A twisted =.8 mm 3 Core C : 8 Cores A twisted = 1 mm 1 cores (B) + 16 cores (C) twisted = 4.7 mm nominal 4 PTFE tape = 4.8 mm nominal. 5 AWG 40 silver plated alloy braid 85 % coverage = 5.2 mm nominal 6 Medical P.V.C = 7.2 ±.3 mm Medical Ultrasound cable Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Ultrasound cable assemblies. Characteristic impedance : 50 Ω nominal Linear capacitance : 95 ± 10 pf/m (at 95%).(29 pf/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-31 -

Filotex STUDY 124541 192 + 4 channels 40 AWG coax cable FILOTEX Ref : ET 124 541 Multi coax 55pF/m 1 Core A : AWG 40 stranded 7x.03mm silver plated alloy PD 135. FEP «SE» insulation =.34 ±.02 mm AWG 48 silver plated copper Helicoidal screen =.40mm nominal FEP jacket =.46 ±.02mm 2 Core B : 16 Cores A twisted = 2.1mm 3 Core C : 4 Cores A twisted =.95mm 12 cores (B) + 1 core C 4 5 6 twisted =7.7mm nominal PTFE tape = 7.75mm nominal. AWG 40 tin plated copper braid 85 % coverage = 8.1mm nominal Medical PVC = 9.6 ±.3mm Medical Ultrasound cable Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Ultrasound cable assemblies. Characteristic impedance : 80 Ω nominal Linear capacitance : 18 ± 2 pf/ft (at 95%) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 500 V AC 1 mn Max DC resistance of centre conductor : 1.2 Ω/ft Max DC resistance of coax shield : 15 Ω/ft Insulation resistance : > 10 MΩ Crosstalk coax to coax, 1 ~ 10 Mhz in 96 inches long cable will all ends terminated in 80 Ω : < 55 db One way signal loss (1 ~ 10 Mhz) : < 0.10 db/ft Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-32 -

Filotex STUDY 132081 256 + 8 channels 40 AWG coax cable Medical Ultrasound cable FILOTEX Ref : ET 132 081 Multicoax 95pF/m 1 Core A : AWG 40 stranded silver plated alloy. FEP insulation =.24 ±.02 mm AWG 48 silver plated copper Helicoidal screen =.3 mm nominal FEP jacket =.39 ±.02 mm 2 Core B : 16 Cores A twisted = 1.9 mm 3 Core C : 8 Cores A twisted = 1.2 mm 16 cores (B) + 1 core (C) twisted = 7.6 mm nominal 4 PTFE tape = 7.65 mm nominal. 5 Medical P.V.C = 9.6 ±.30 mm Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Ultrasound cable assemblies. Characteristic impedance : 50 Ω nominal Linear capacitance : 95 ± 10 pf/m (at 95%).(29pF/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn DC resistance : <= 1.2 Ω/ft Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-33 -

Part 5 Microcables for CCD cameras applications Issue 1 - November 2000-34 -

Microcables for Endoscopy Available models 3.5 mm ET 123602 5 mm ET 132468 ET 123540 ET 124991 ET 124692 7 mm ET 132028 Optional UL style approval : UL20379 Issue 1 - November 2000-35 -

Filotex STUDY 123602 9 channels 38 AWG coax + 5 x 38 AWG wires Medical Video Endoscopy cable FILOTEX Ref : ET 123 602 Video camera Cable 1 Core A : AWG 38 stranded silver plated alloy. FEP insulation =.34 ±.02mm AWG 44 silver plated copper Helicoidal screen =.44mm nominal FEP jacket =.53 ±.02 mm 2 Core B : AWG 38 stranded silver plated alloy. FEP insulation =.34 ±.05mm 3 Fillers 9 Cores (A) + 5 cores (B) + Fillers twisted = 2.05 mm nominal 4 PTFE tape = 2.07 mm nominal. 5 AWG 40 tin plated copper braid 85 % coverage = 2.5mm nominal 6 Medical PVC = 3.45 ±.1mm Very flexible cable with an extremely good mechanical behaviour Withstands miscellaneous sterilisation processes Video Endoscopy cable assemblies Characteristic impedance (core A) : 50 nominal Linear capacitance (core A) : 95 ± 10 pf/m (at 95%) (29pF/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter. Issue 1 - November 2000-36 -

Filotex STUDY 132468 1 channel 30 AWG coax + 11 x 28 AWG wires Medical Video Endoscopy cable FILOTEX Ref : ET 132 468 Video camera Cable 1 Core A : AWG 30 (19 x 42 AWG) stranded silver plated alloy. FEP insulation =.82 ±.05mm AWG 40 silver plated copper braid = 1.20mm nominal FEP jacket = 1.55 ±.05mm 2 Core B: AWG 28 (19 x 40 AWG) stranded silver plated copper. FEP insulation =.60 ±.05mm 1 Core (A) + 11 cores (B) twisted = 2.75 mm nominal 3 PTFE tape. = 2.90 mm nominal 4 AWG 40 silver plated copper spiral shield = 3.25 mm nominal 5 PTFE tape. = 3.4mm nominal 6 Medical PVC = 5.45 ±.2mm Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Video endoscopy cable assemblies Characteristic impedance core (B and D) : 50 Ω nominal Linear capacitance core (B and D) : 110±10 pf/m (at 95%) (33 pf/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-37 -

Filotex STUDY 123540 2 channels 34 AWG coax + 5 x 28 AWG wires Medical Video Endoscopy cable FILOTEX Ref : ET 123 540 Video camera Cable 1 Core A : AWG 34 stranded silver plated alloy. PFA insulation =.53 ±.03mm AWG 44 silver plated copper Helicoidal screen =.63mm nominal PFA jacket =.98 ±.05mm 2 Core B : AWG 28 stranded tin plated copper. PVC insulation = 1.1 ±.05mm 2 core (A) + 5 cores (B) twisted = 3.3 mm nominal 3 PTFE tape = 3.35 mm nominal 4 AWG 41 tin plated copper braid 85% coverage = 3.7 mm nominal 5 Medical PVC = 5.0±15mm Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes Video Endoscopy cable assemblies Linear capacitance core (A) : 100 pf/m nominal DC resistance (A) : 95 Ω/100m nominal Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter. Issue 1 - November 2000-38 -

Filotex STUDY 124991 5 channels 30 AWG coax + 3 x 30 AWG wires Medical video Endoscopy cable FILOTEX Ref : ET 124 991 1 Core A : AWG 30 stranded silver plated copper. FEP insulation =.80 ±.02mm AWG 38 silver plated copper helicoidal screen = 1.0 mm nominal FEP jacket = 1.2 ±.03 mm 2 Core B: AWG 30 stranded silver plated copper. PTFE insulation =.81 ±.05mm 5 Cores (A) + 3 cores (B) twisted = 4.05 mm nominal 3 4 PTFE tape AWG 40 tin plated copper braid 85% coverage = 4.4mm nominal 5 Polyurethane = 5.7 ±.2mm Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Medical cable assemblies. Characteristic impedance core (A) : 50 nominal Linear capacitance core (A) : 95 ± 10 pf/m (at 95%).(29 pf/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-39 -

Filotex STUDY 124692 9 channels 32 AWG coax + 3 x 26 AWG wires FILOTEX Ref : ET 124 692 Video camera Cable 1 Core A : AWG 32 stranded silver plated alloy. FEP insulation =.65 ±.03mm AWG 44 silver plated copper Helicoidal screen =.75mm nominal FEP jacket =.91 ±.05mm 2 Core B : AWG 26 stranded tin plated copper. FEP insulation =.81 ±.05mm 9 Cores (A) + 3 cores (B) twisted = 3.6mm nominal 3 PTFE tape = 3.65mm nominal. 4 AWG 40 tin plated copper braid 85 % coverage = 4.1mm nominal 5 Medical PVC = 5.0 ±.2mm Medical Video Endoscopy cable Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Video endoscopy cable assemblies Characteristic impedance core (A) : 50 nominal Linear capacitance core (A) : 95 ± 10 pf/m (at 95%).(29 pf/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-40 -

Filotex STUDY 132028 3 channels 28 AWG coax 6 channels 32 AWG coax + 3 x 26 AWG wires FILOTEX Ref : ET 132 028 Video Camera Cable 1 Core A : AWG 28 stranded silver plated alloy. FEP insulation = 1.1 ±.05 mm AWG 40 silver plated copper Helicoidal screen = 1.26 mm nominal FEP jacket = 1.58 ±.05 mm 2 Core B : AWG 32 stranded silver plated alloy. FEP insulation =.63 ±.05 mm AWG 44 silver plated copper Helicoidal screen =.73 mm nominal FEP jacket =.91 ±.05 mm 3 Core C : AWG 26 stranded silver plated copper. FEP insulation =.80 ±.05 mm 4 Cotton filler 3 Cores (A) + 6 cores (B) + 3 cores (C) twisted = 4.4 mm nominal 5 PTFE tape = 4.45 mm nominal. 6 AWG 40 tin plated copper braid 85 % coverage = 4.8 mm nominal 7 Medical PVC = 6.8 ±.2 mm Medical Video Endoscopy cable Very flexible cable with an extremly good mechanical behaviour. Withstands miscellaneous sterilization processes. Video endoscopy cable assemblies. Characteristic impedance core (A) : 50 nominal Linear capacitance core (A) : 80 pf/m nominal Characteristic impedance core (B) : 50 nominal Linear capacitance core (B) : 95 pf/m nominal Continuous operating voltage : 30 V eff. Test voltage between core and screen : 500 V AC 1 mn Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-41 -

Microcables for Dental application Issue 1 - November 2000-42 -

Filotex STUDY 124844 1 channels 34 AWG coax + 8 x 34 AWG wires + 2 x 30 AWG wires Dental cable FILOTEX Ref : ET 124 844 Video camera Cable 1 Core A : AWG 34 stranded silver plated alloy. PFA insulation =.53 ±.03mm AWG 44 silver plated copper Helicoidal screen nominal =.63mm PFA jacket =.83 ±.05mm 2 Core B : AWG 30 stranded silver plated alloy. PFA insulation =.50 ±.05mm 3 Core C : AWG 34 stranded silver plated alloy. PFA insulation =.36 ±.05mm 1 core (A) + 2 cores (B) + 8 cores (C) twisted = 2.05mm nominal 4 34 AWG silver plated alloy Drain wire 5 PTFE tape = 2.10 mm nominal 6 AWG 40 silver plated alloy braid 85 % coverage = 2.60 mm nominal 7 Medical PVC = 4.1 ±.15mm Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Video endoscopy cable assemblies. Linear capacitance core (A) : 100 pf/m nominal DC resistance core (A) : 95 Ω/100m nominal DC resistance core (B) : 33.7 Ω/100m nominal DC resistance core (C) : 95 Ω/100m nominal Test voltage between braid and outside : 4000 V AC 1 mn Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-43 -

Filotex STUDY 132331 2 channels 36AWG coax + 9 x 32 AWG wires + 10 x 32 AWG wires Dental cable FILOTEX Ref : ET 132 331 Video camera Cable 1 Core A : AWG 36 stranded silver plated alloy PFA insulation =.52 ±.03mm AWG 44 silver plated copper Helicoidal screen =.62mm nominal PFA jacket =.72 ±.05mm 2 Core B : AWG 32 stranded silver plated alloy PFA insulation =.42 ±.05mm 2 cores (A) + 9 cores (B) twisted =.2.3 nominal 3 PTFE tape 2.35 mm nominal. 4 AWG 40 silver plated copper braid 85% coverage = 2.7mm nominal 5 2 Medical PTFE tapes =3.2 ± 3.2mm max 6 Optional fillers 7 10 cores (B) around = 4.05mm 8 PTFE tape = 4.1mm nominal 9 Medical PVC = 5.3 ±.2mm Very flexible cable with an extremely good mechanical behaviour Withstands miscellaneous sterilisation processes Video endoscopy cable assemblies Characteristic impedance : 60 nominal Linear capacitance : 80pF/m nominal Continuous operating voltage : 24 V eff. DC resistance core (A) : 150 Ω/100m DC resistance core (B) : 600 Ω/100m Test voltage between core and screen : 350 V DC 1 mn Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter 9 8 7 6 5 4 3 2 1 Issue 1 - November 2000-44 -

Filotex STUDY 132116 2 x 36 AWG twisted pairs + 14 x 36 AWG wires Dental cable FILOTEX Ref : ET 132 116 Video camera Cable 1 Core A : AWG 36 stranded silver plated alloy. FEP insulation =.24 ±.03mm 2 Core B : AWG 36 stranded silver plated alloy. FEP insulation =.28 ±.05mm 3 Core C : 2 cores (A) twisted, pitch 5mm nominal (8 mm maxi) 4 Kevlar member 158 TEX Tensile strength > 20 kgf 2 core (C) + 14 cores (B) + Kevlar member twisted, pitch 10mm nominal = 1.7mm max 5 PTFE tape 6 AWG 40 silver plated alloy braid 95 % coverage, pitch 10mm nominal = 2.2mm nominal 7 PTFE tape = 2.4mm max 8 Polyurethane = 3.6mm max Thickness.60 ±.05 mm Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Video endoscopy cable assemblies. Linear capacitance core (C) : 63 pf/m nominal Linear capacitance between 2 cores (B) : 43 pf/m nominal Linear capacitance between cores (B) and braid : 80 pf/mnominal All capitance must be verify on a sample DC resistance core (A) and (B) : 2.07 Ω/m nominal 2.2 Ω/m max Test voltage between braid and outside : 500 V AC Spark test of jacket : 1500 V AC Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-45 -

Filotex STUDY 132182 8 x 36 AWG twisted pairs + 3 x 36 AWG wires Dental cable FILOTEX Ref : ET 132182 Video camera Cable 1 Core A :AWG 36 stranded silver plated alloy. FEP insulation =.24 ±.03mm 2 Core B :AWG 36 stranded silver plated alloy. FEP insulation =.28 ±.05mm 3 Core C : 2 cores (A) twisted, pitch 8mm nominal(10 mm maxi) 4 Kevlar member 158 TEX Tensile strength > 20 kgf 5 Core D : 3 cores (B) twisted + Kevlar member, pitch 9mm nominal (12mm maxi) 1 core (D) + 8 cores (C) twisted, pitch 15 to 25mm = 1.7mm max 6 PTFE tape unsintered 7 AWG 42 hard silver plated alloy braid 95 % coverage, pitch 10mm nominal = 2.15mm nominal 8 PTFE tape unsintered = 2.35mm max 9 Polyurethane = 3.6mm max Thickness.60 ±.05mm All copper alloy are without cadmium. Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Video endoscopy cable assemblies Linear capacitance core (C) : 60 pf/m maxi Linear capacitance between 2 cores (B) : 15 pf/m nominal Linear capacitance between cores (C) and braid : To be define on sample All capacitance must be verify on a sample DC resistance core (A) & (B) : 1.52 Ω/m nominal. 1.6 Ω/m max. Test voltage conductor/conductor : 500 VAC Spark test of jacket : 1500 VAC Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter 9 8 7 6 5 4 3 2 1 Issue 1 - November 2000-46 -

Part 6 Microcables for other medical applications Issue 1 - November 2000-47 -

Microcables for Catheter Issue 1 - November 2000-48 -

Filotex STUDY 132183 3 x 2 wires 44 AWG Cable for catheter FILOTEX Ref : ET 132 183 1 Core A : AWG 44 silver plated copper. Enamel lacquer =.06 ±.005 mm 2 Core B : 2 cores A twisted =.12mm 3 4 3 cores (B) twisted =.22mm nominal AWG 48 silver plated copper spiral shield =.28mm nominal FEP =.40 ±.02 mm Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. Ultrasound cable assemblies Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn Operating temperature : - 30 C to +150 C (200 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-49 -

Filotex STUDY 124524 5 x 30 AWG wires FILOTEX Ref : ET 124 524 1 Core A : AWG 30 stranded silver plated copper. PTFE insulation =.61 ±.05mm 2 Core B : AWG 30 stranded silver plated copper drain wire. 3 Core C : 2 cores (A) + 1 core (B) twisted Polyester/Aluminium tape 1 core (C) + 3 cores (A) twisted 4 PTFE tape = 5.55 mm nominal 5 AWG 38 tin plated copper helicoidal screen. 6 Polyurethane = 3.55 ±.15mm Cable for catheter Very flexible cable with an extremely good mechanical behaviour. Continuous operating voltage : 250 V Operating temperature : - 60 C to +85 C Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-50 -

Microcables for patient monitoring (invasive applications) Issue 1 - November 2000-51 -

Filotex STUDY 123546 2 channels 36 AWG coax cable Medical cable for patient monitoring FILOTEX Ref : ET 123 546 Multi coax 95pF/m 1 Core A : AWG 36 silver plated alloy wire. FEP insulation =.32 ±.03mm AWG 44 silver plated copper Helicoidal screen =.42mm nominal FEP jacket =.52 ±.03mm 2 Cores (A) + 2 cores (B) twisted = 1.02 mm nominal 2 AWG 44 tin plated copper helicoidal screen = 1.12mm nominal 3 Superpolyamide = 1.5 ± 1 mm This cable is not round. Very flexible cable with an extremely good mechanical behaviour Withstands miscellaneous sterilisation processes Ultrasound cable assemblies s Characteristic impedance : 50 nominal Linear capacitance : 95 ± 10 pf/m (at 95%) (29pF/ft) Continuous operating voltage : 24 V eff. Test voltage between core and screen : 350 V DC 1 mn Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter 3 2 1 Issue 1 - November 2000-52 -

Microcables for ECG Issue 1 - November 2000-53 -

Filotex STUDY 022595 ECG cable Medical ECG cable FILOTEX Ref : ET 022 595 Low noise cable 1 24 x.05 mm stranded copper =.28 mm nominal 2 Polyethylene insulation =.70 ±.05mm 3 Semi-conductive layer =.73mm nominal 4.07 mm copper braid = 1mm nominal 5 PVC jacket = 1.4mm nominal. Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. ECG cable assemblies. Continuous operating voltage : 250 V eff. Operating temperature : - 30 C to + 85 C (100 C at peak) Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-54 -

Temporary myocard pacing wire Issue 1 - November 2000-55 -

Filotex STUDY 060517 FILOTEX Ref : ET 060 517 1 19 x 0.06 stranded stainless steel 316L 2 PE insulation =.65 ±.03mm Temporary myocard pacing wire Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes DC resistance : 16 Ω/m Insulation resistance : 100 MΩ.km Dielectric strength : 1500 V DC Operating temperature : - 50 C to + 200 C Minimum bending radius : 5 x Overall diameter. Pull-off force : 5 N to 15 N Issue 1 - November 2000-56 -

Filotex STUDY 132070 1 19 x 0.044 stranded stainless steel 316L =.22 ±.02mm 2 FILOTEX Ref : ET 132 070 PE insulation =.48 ±.02mm Temporary myocard pacing wire Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes DC resistance : 30 Ω/m Insulation resistance : 100 MΩ.km Dielectric strength : 1500 V DC Operating temperature : - 50 C to + 200 C Minimum bending radius : 5 x Overall diameter. Pull-off force : 5 N to 15 N Issue 1 - November 2000-57 -

Filotex STUDY 132524 Temporary myocard pacing wire FILOTEX Ref : ET 132 524 1 19 x.044 mm stranded stainless steel 316L =.22 ±.02 mm 2 Polyethylene insulation =.40 ±.02 mm 3 0.044 mm stainless steel 316L helicoidal screen min. coverage 90 % =.49 ±.02 mm 4 Polyethylene jacket =.75 ±.05mm Very flexible cable with an extremely good mechanical behaviour. Withstands miscellaneous sterilisation processes. DC resistance of inner conductor : 50 Ω/m DC resistance of outer conductor : 30 Ω/m Insulation resistance of insulation : 100 MΩ.km Insulation resistance of jacket : 100 MΩ.km Dielectric strength : 1500 V DC Operating temperature : - 30 C to + 75 C Minimum bending radius : 5 x Overall diameter Issue 1 - November 2000-58 -