AAMA/WDMA/CSA 101/I.S.2/A440-05. Standard/Specification for windows, doors, and unit skylights EXCERPT EDITION



Similar documents
Specifying Windows. Performance Standards

T H E A A M A C E R T I F I C A T I O N P R O G R A M

NAFS and The 2012 Building Code

TEST REPORT. Rendered to: INTERNATIONAL WINDOW Hayward, California. PRODUCT TYPE: Aluminum Hopper SERIES/MODEL: 7222

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: EAGLE WINDOW & DOOR COMPANY

TEST REPORT. Report No.: B Rendered to: CROFT, LLC. Magnolia, Mississippi. PRODUCT TYPE: Aluminum Single Hung Window SERIES/MODEL: 95

Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls and Sloped Glazing Systems

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

ALUMINUM Guide Spec: Standard Aluminum Windows & Doors

Size & Range. for windows & doors. Company

Table of Contents PART 1 WINDOW SELECTION GUIDE. Window and Door Selection Guide

Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

Window Types and Materials

continuing professional education. As such, it construed to be an approval or endorsement by

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

Tuscany Series Vinyl Replacement Windows 3-Part Specification

IAN BENNIE AND ASSOCIATES TEST REPORT NO S2 AWNING WITH FIXED WINDOW PROTOTYPE TEST to AS for. Finesse Window Systems Australia

Astragal: a vertical member placed at the meeting edges of a double door to provide a weather seal and may be used to anchor the fixed door.

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

CHAPTER 24 GLASS AND GLAZING

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems

AAMA Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure

DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1

TECHNICAL MANUAL. airlite.com.au

PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM CORPORATION. SERIES/MODEL: 450 Center Glaze PRODUCT TYPE: Aluminum Curtain Wall

Excerpts from the Canadian National Building Code (NBC)

Scottsdale, Arizona. Presentation by: Hermes Norero, P.E. President and CEO

Relevant British, European and International standards

PERFORMANCE EVALUATION OF THE CERAMITEX RVR SYSTEM IN ACCORDANCE WITH AAMA FOR PRESSURE EQUALIZATION BEHAVIOR & WATER PENETRATION RESISTANCE

Glossary. Argon: An inert, nontoxic gas used in insulating glass units to reduce heat transfer.

PERFORMANCE TEST REPORT

Testing Water Penetration Resistance of Window Systems Exposed to Realistic Dynamic Air Pressures

PERFORMANCE TEST REPORT. Rendered to: TREMCO INCORPORATED. SERIES/MODEL: Proglaze ETA PRODUCT TYPE: Engineered Transition Assembly

Field Water Testing - Lessons Learned

PERFORMANCE TEST REPORT. Rendered to: ARCHITECTURAL METAL SOLUTIONS, INC.

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

DOMUS & ALDUS THE WINDOW CONCEPT WITH A STUNNINGLY MODERN APPEARANCE

CHAPTER 24 GLASS AND GLAZING

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal

research highlight Water Penetration Resistance of Windows - Study of Codes, Standards,Testing, and Certification

A site plan or floor plan clearly identifying the location(s) of all new replacement window(s)

The replacement or modification of existing windows shall comply with the following requirements:

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida

City of Peterborough

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

CERTIFICATE OF APPROPRIATENESS Planning and Development Department, Neighborhood Services

Installer Training and Certification Overview

Series 3502 Thermal Series 3902 Fixed Thermal Architectural Grade Horizontal Sliding Window

Victims Compensation Claim Status of All Pending Claims and Claims Decided Within the Last Three Years

AutoCAD Architecture 2012 UK Content Tools

How To Test For An Architectural Test

REPORT NUMBER: COQ-003 ORIGINAL ISSUE DATE: July 19, 2013

Windows & Doors Standard Sizes

Introduction...COMB-2 Design Considerations and Examples...COMB-3

City of San Diego, CWP Guidelines

Sample Calculations...V-CR-12. Door and Window Typical Combinations... V-CR-12 Horizontal and Vertical Typical Combinations...

Evidence of Performance. Class 2. Class 5A. Class C4 / B4. Test Report No PR01. ift Rosenheim

Dollars & Sense of Compliance!

Insider Tips for Purchasing Replacement Windows

Evidence of Performance Resistance to wind load Watertightness Air permeability

SECTION METAL WALL PANELS

Annual Report H I G H E R E D U C AT I O N C O M M I S S I O N - PA K I S TA N

Casement/Awning Window Parts Reference Catalog

TOPLIGHTS. NOTE: 2.4m high sliding doors are only available in certain configurations and sizes.

Product information. Schüco Window AWS /Web Schüco AWS

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Replacement Windows and Doors

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

SECTION VINYL WINDOWS. A. The General Conditions, Supplementary Conditions, and Division 01 - Requirements apply.

JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC ALUMINUM WINDOWS Guide Specs

Impact-Resistant Windows and Sliding Glass Doors

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: Atrium Companies, Inc. SERIES/MODEL: 50/305 HS PRODUCT TYPE: Vinyl Horizontal Slider

Enhancing The Beauty And Value Of Your Home. Exclusive Patio Door Collection. NORTH STAR PATIO DOOR COLLECTION Two-Panel Three-Panel Four-Panel

Quality Windows And Doors. Great Service. Exceptional Value.

Application for a Window Replacement Master Plan Curtis B. Wayne, Architect Ken Lustbader, Preservation Consultant

Window Installation Instructions

Quality Windows And Doors. Great Service. Exceptional Value.

IECC Compliance Guide for Homes in Virginia

Glossary. 1/3 1/3 1/3 - Configuration of a vent-fixed-vent (xox) window in which the vents and fixed panel are equal sizes

Residential Windows, 3 rd edition Corrected index 1

NanaWall SL73 - Thermally Broken Aluminum Framed Hurricane Rated Folding System with Miami Dade County, Florida NOA

THE ULTIMATE HIGH PERFORMANCE REPLACEMENT WINDOWS AND PATIO DOORS

Building Control Guidance Note

Installation Detailed installation instructions are provided which should be strictly followed.

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: CAPTIVEAIRE, INC. Blue Bell, Pennsylvania

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

WATER TESTING MISCONCEPTIONS: F ENESTRATION PRODUCT CERTIFICATION AND FORENSIC INVESTIGATION OF BUILDING LEAKAGE

western transforming space window systems series 670 a new option for hinged window line

to encourage high quality tropical vernacular Queensland architecture throughout the Shire;

ENERGY EFFICIENT WINDOWS & DOORS A GUIDE TO THERMAL PERFORMANCE. Building Solutions Automotive Industry

Section Aluminum Windows (4600 Series Specifications)

Garden Windows Builders Vinyl

REPORT ON THE TESTING OF SEALED UNITS TO VERIFY THE IMPACT OF PRESSURE EQUALISATION ON INSULATION VALUES.

2009 IECC Update. Scope. Content. International Energy Conservation Code

Transcription:

AAMA/WDMA/CSA 101/I.S.2/A440-05 Standard/Specification for windows, doors, and unit skylights EXCERPT EDITION Product Designations (Product Types, Performance Classes & Grades), and Gateway Performance Requirements CMB-5-05

4 General Requirements 4.1 General - This voluntary Standard/Specification covers requirements for single and dual windows, single and dual side-hinged door systems, sliding doors, and unit skylights for new construction and replacement applications. All products rated in accordance with this Standard/Specification shall conform to all the requirements of this Standard/Specification. All products covered by this Standard/Specification shall be installed in full accordance with the manufacturer s instructions. 4.2 Markings/Identifications - When required by local code or project specification, windows, doors, and unit skylights shall include a permanent identification of the product manufacturer. 4.3 Gateway Performance Requirements - Each product type has a defined gateway set of primary requirements for the applicable product type before entry into the performance class is permitted (see Table 1). Gateway performance requirements are the minimum allowable performance levels that a gateway test specimen shall achieve in order for a product to be rated with a particular classification (R, LC, C, HC, or AW). The gateway test specimen size shall be equal to or larger than the specified gateway size, in both height and width. Typically, the minimum allowable performance levels and the gateway size change as the classification changes. All gateway test specimens shall achieve certain minimum performance levels for air leakage resistance, water penetration resistance, uniform load, and, where required, forced-entry resistance and operating force. Also, all gateway test specimens shall achieve certain additional minimum performance levels for auxiliary (durability) and material tests specific to the product operator type. See Clause 5 for additional details. Product Performance Class Minimum Performance Grade Minimum Design Pressure, Pa (psf) Minimum Structural Test Pressure, Pa (psf) Minimum Water Resistance Test Pressure, Pa (psf) Windows and doors R 15 720 (15.0) 1080 (22.5) 140 (2.90) LC 25 1200 (25.0) 1800 (37.5) 180 (3.75) C 30 1440 (30.0) 2160 (45.0) 220 (4.50) HC 40 1920 (40.0) 2880 (60.0) 290 (6.00) AW 40 1920 (40.0) 2880 (60.0) 390 (8.00) Unit skylights and roof windows R 15 720 (15.0) 1440 (30.0) 140 (2.90) C 30 1440 (30.0) 2880 (60.0) 220 (4.50) HC 40 1920 (40.0) 3840 (80.0) 290 (6.00) TABLE 1 GATEWAY REQUIREMENTS 4.4 Product Designations 4.4.1 General - A primary designator shall be used to designate products included in this Standard/Specification. An optional secondary designator shall be permitted to be used if desired. 4.4.2 Primary Designator 4.4.2.1 General - The primary designator in this Standard/Specification is a four-part code, which includes product type, performance class, performance grade (design pressure), and maximum size tested to achieve this rating. For reporting purposes, the product type shall be typed in full or represented by abbreviations as shown in Figures 2 to 4. Abbreviations shall be as per Table 2. An asterisk (*) added to the size designation indicates that the size tested was an additional test unit that was smaller than the gateway test size for the original product type and performance class, for the purpose of meeting optional performance grade (design pressure) requirements. An example is shown in Figure 3. See Clause 4.4.2.6 for further details regarding optional performance grades (design pressures). Hung Window R30 800 x 1800* (32 x 71*) H R30 800 x 1800* (32 x 71*) or or Hung Window RM1440 800 x 1800* H RM 1440 800 x 1800* Legend: Hung Window or H - product type (see Clause 4.4.2.1) R - performance class (inch-pound) (see Clauses 0.2.1 and 4.4.2.3) RM - performance class (SI) (see Clauses 0.2.1 and 4.4.2.3) 30 - performance grade (design pressure) (inch-pound) (see Clauses 0.2.3, 4.4.2.4, and 4.4.2.6) 1440 - performance grade (design pressure) (SI) (see Clauses 0.1.2.3, 4.4.2.4, and 4.4.2.6) 800 x 1800 - maximum size tested (SI) (see Clause 4.4.2.5) (32 x 71) - maximum size tested (inch-pound) (optional) (see Clause 4.4.2.5)

* - downsized test specimen FIGURE 3 PRIMARY DESIGNATOR (EXAMPLE 2) The characters LW shown in the product type in Figure 4 indicate limited water penetration resistance. LW ratings shall only be permitted for side-hinged door systems, and shall not be permitted for any other product types. Also, LW ratings shall only be permitted where the representative test specimen has successfully passed a water penetration resistance test at a pressure differential of 0 Pa (0.0 psf) or higher, but less than the minimum test pressure required for the indicated performance class and performance grade (design pressure). If the test specimen is not successfully tested to a water penetration resistance test pressure equal to or greater than 0 Pa (0.0 psf), then that side-hinged door system shall not be considered in compliance with this Standard/Specification. An example is shown in Figure 4. Limited Water Side-Hinged Door R40 900 x 2000 (36 x 79) LW SHD R40 900 x 2000 (36 x 79) or or Limited Water Side-Hinged Door RM1920 900 x 2000 LW SHD RM1920 900 x 2000 Legend: LW - limited water Side-Hinged Door or SHD - product type (see Clause 4.4.2.1) R - performance class (inch-pound) (see Clauses 0.2.1 and 4.4.2.3) RM - performance class (SI) (see Clauses 0.2.1 and 4.4.2.3) 40 - performance grade (design pressure) (inch-pound) (see Clauses 0.2.3, 4.4.2.4, and 4.4.2.6) 1920 - performance grade (design pressure) (SI) (see Clauses 0.2.3, 4.4.2.4, and 4.4.2.6) 900 x 2000 - maximum size tested (SI) (see Clause 4.4.2.5) (36 x 79) - maximum size tested (inch-pound) (optional) (see Clause 4.4.2.5) FIGURE 4 PRIMARY DESIGNATOR (EXAMPLE 3) Products that have been tested as dual windows as specified in Clause 4.5 shall have the code DW added to their product designation after the product type. An example of a product designation for a dual window would be HS DW LC25 1800 1400. Products that have been tested as dual doors as specified in Clause 4.5 shall have the code DD added to their product designation after the product type. An example of a product designation for a dual door would be SHD DD LC25 900 2100. 4.4.2.2 Product Type - When used, product designations shall be as per Table 2 for the window, door, and unit skylight product types covered in this Standard/Specification. The depictions in Figure 5 are general in nature and are not all-inclusive. AP = Awning, hopper, projected window LW DASHD = Limited water dual-action side-hinged door ATD = Architectural terrace door LW SHD = Limited water side-hinged door BW = Basement window RW = Roof window C = Casement window SD = Sliding door DASHD = Dual-action side-hinged door SHD = Side-hinged door DAW = Dual-action window SHW = Side-hinged (inswinging) window FD = Fixed door SKG = Unit skylight glass glazed FW = Fixed window SKP = Unit skylight plastic glazed GH = Greenhouse window SLT = Side lite H = Hung window SP = Specialty product HE = Hinged rescue window TA = Tropical awning window HP = Horizontally pivoted window TH = Top-hinged window HS = Horizontal sliding window TR = Transom J = Jalousie window VP = Vertically pivoted window JA = Jal-awning window VS = Vertical sliding window TABLE 2 PRODUCT TYPES 4.4.2.3 Performance Class Products included in this Standard/Specification shall be classified according to any of the five performance classes (R, LC, C, HC, and AW) as described in Clause 0.2.1 and Table 1.

Product Type Architectural terrace door Awning, hopper, projected window Product Designation TABLE 25 GATEWAY PERFORMANCE REQUIREMENTS Minimum Test Size, mm (in) Minimum Design Pressure, Pa (lbf/ft 2 ) Deflection at Design Pressure, mm (in) Minimum Structural Pressure, Pa (lbf/ft 2 ) Minimum Water Air Leakage Resistance Pressure, Pa (lbf/ft 2 ) Pa (lbf/ft 2 ) L/s m 2 (cfm/ft 2 ) ATD-HC40 1060 2280 (42 90) 1920 (40.0) L/175 2880 (60.0) 290 (6.0) 300 (6.2) 1.5 (0.3) ATD-AW40 1200 2430 (48 96) 1920 (40.0) L/175 2880 (60.0) 390 (8.0) 300 (6.2) 0.5 (0.1) AP-R15 1200 400 (48 16) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) AP-LC25 1200 800 (48 32) 1200 (25.0) Reported 1800 (37.5) 180 (3.8) 75 (1.6) 1.5 (0.3) AP-C30 1200 800 (48 32) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) AP-HC40 1500 800 (60 32) 1920 (40.0) L/175 2880 (60.0) 290 (6.0) 300 (6.2) 1.5 (0.3) AP-AW40 1500 900 (60 36) 1920 (40.0) L/175 2880 (60.0) 390 (8.0) 300 (6.2) 0.5 (0.1) Basement window BW-R15 800 360 (32 14) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) Casement window Dual-action side- hinged door Dual-action window Fixed door Fixed window C-R15 600 1500 (24 60) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) C-LC25 800 1500 (32 60) 1200 (25.0) Reported 1800 (37.5) 180 (3.8) 75 (1.6) 1.5 (0.3) C-C30 800 1500 (32 60) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) C-HC40 900 1500 (36 60) 1920 (40.0) L/175 2880 (60.0) 290 (6.0) 300 (6.2) 1.5 (0.3) C-AW40 900 1500 (36 60) 1920 (40.0) L/175 2880 (60.0) 390 (8.0) 300 (6.2) 0.5 (0.1) DASHD-R15 900 2000 (36 79) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) DASHD-LC25 900 2100 (36 83) 1200 (25.0) Reported 1800 (37.5) 180 (3.8) 75 (1.6) 1.5 (0.3) DASHD-C30 1000 2100 (40 83) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) DASHD-HC40 1200 2400 (48 95) 1920 (40.0) L/175 2880 (60.0) 290 (6.0) 300 (6.2) 1.5 (0.3) DAW-R15 1100 1500 (44 60) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) DAW-LC25 1200 1500 (48 60) 1200 (25.0) Reported 1800 (37.5) 180 (3.8) 75 (1.6) 1.5 (0.3) DAW-C30 1200 1800 (48 71) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) DAW-HC40 1500 2500 (60 99) 1920 (40.0) L/175 2880 (60.0) 290 (6.0) 300 (6.2) 1.5 (0.3) DAW-AW40 1500 2500 (60 99) 1920 (40.0) L/175 2880 (60.0) 390 (8.0) 300 (6.2) 0.5 (0.1) FD-R15 900 2000 (36 79) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) FD-LC25 900 2100 (36 83) 1200 (25.0) Reported 1800 (37.5) 180 (3.8) 75 (1.6) 1.5 (0.3) FD-C30 1000 2100 (40 83) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) FD-HC40 1200 2400 (48 95) 1920 (40.0) L/175 2880 (60.0) 290 (6.0) 300 (6.2) 1.5 (0.3) FD-AW40 1500 2500 (60 99) 1920 (40.0 L/175 2880 (60.0) 390 (8.0) 300 (6.2) 0.5 (0.1) FW-R15 1200 1200 (48 48) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) FW-LC25 1400 1400 (56 56) 1200 (25.0) Reported 1800 (37.5) 180 (3.8) 75 (1.6) 1.5 (0.3) FW-C30 1500 1500 (60 60) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) FW-HC40 1500 1800 (60 71) 1920 (40.0) L/175 2880 (60.0) 290 (6.0) 75 (1.6) 1.5 (0.3) FW-AW40 1500 2500 (60 99) 1920 (40.0) L/175 2880 (60.0) 390 (8.0) 300 (6.2) 0.5 (0.1) Greenhouse window GH-R15 900 x 900 x 300 (36 36 x 12) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) Hinged rescue window HE-R15 Varies 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) Horizontally or vertically pivoted window Horizontal sliding window HP/VP-R15 1100 1500 (44 60) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) HP/VP-LC25 1200 1500 (48 60) 1200 (25.0) Reported 1800 (37.5) 180 (3.8) 75 (1.6) 1.5 (0.3) HP/VP-C05 1200 2200 (48 87) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) HP/VP-HC40 1500 2500 (60 99) 1920 (40.0) L/175 2880 (60.0) 290 (6.0) 300 (6.2) 1.5 (0.3) HP/VP-AW40 1500 2500 (60 99) 1920 (40.0) L/175 2880 (60.0) 390 (8.0) 300 (6.2) 0.5 (0.1) HS-R15 1600 1100 (63 44) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) HS-LC25 1800 1400 (71 56) 1200 (25.0) Reported 1800 (37.5) 180 (3.8) 75 (1.6) 1.5 (0.3) HS-C30 1800 1500 (71 60) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) HS-HC40 2500 2000 (99 79) 1920 (40.0) L/175 2880 (60.0) 290 (6.0) 300 (6.2) 1.5 (0.3) HS-AW40 2500 2000 (99 79) 1920 (40.0) L/175 2880 (60.0) 390 (8.0) 300 (6.2) 1.5 (0.3)

Product Type Hung window vertical sliding Product Designation Minimum Test Size, mm (in) Minimum Design Pressure, Pa (lbf/ft 2 ) Deflection at Design Pressure, mm (in) Minimum Structural Pressure, Pa (lbf/ft 2 ) Minimum Water Air Leakage Resistance Pressure, Pa (lbf/ft 2 ) Pa (lbf/ft 2 ) L/s m 2 (cfm/ft 2 ) H-R15 1000 1600 (40 63) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) H-LC25 1100 1900 (44 75) 1200 (25.0) Reported 1800 (37.5) 180 (3.8) 75 (1.6) 1.5 (0.3) H-C30 1400 2300 (56 91) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) H-HC40 1500 2500 (60 99) 1920 (40.0) L/175 2880 (60.0) 290 (6.0) 300 (6.2) 1.5 (0.3) H-AW40 1500 2500 (60 99) 1920 (40.0) L/175 2880 (60.0) 390 (8.0) 300 (6.2) 1.5 (0.3) Jal-awning window JA-R15 1400 1600 (56 63) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) Jalousie window J-R15 900 1200 (36 48) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) Non-hung window vertical sliding Side-hinged door VS-R15 1000 1600 (40 63) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) VS-LC25 1100 1900 (44 75) 1200 (25.0) Reported 1800 (37.5) 180 (3.8) 75 (1.6) 1.5 (0.3) VS-C30 1400 2300 (56 91) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) SHD-R15 900 2000 (36 79) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) SHD-LC25 900 2100 (36 83) 1200 (25.0) Reported 1800 (37.5) 180 (3.8) 75 (1.6) 1.5 (0.3) SHD-C30 1000 2100 (40 83) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) SHD-HC40 1000 2100 (40 83) 1920 (40.0) L/175 2880 (60.0) 290 (6.0) 300 (6.2) 1.5 (0.3) SHD-AW40 1200 2400 (48 95) 1920 (40.0) L/175 2880 (60.0) 390 (8.0) 300 (6.2) 0.5 (0.1) Side-hinged window SHW-AW40 1200 1800 (48 71) 1920 (40.0) L/175 2880 (60.0) 390 (8.0) 300 (6.2) 0.5 (0.1) Side lite Sliding door Top-hinged window Transom Tropical awning window (multiple vent) Tropical awning window (single vent) Unit skylight or roof window (glass glazed) Unit skylight or roof window (plastic glazed) SLT-R15 400 2000 (16 79) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) SLT-LC25 400 2100 (16 83) 1200 (25.0) Reported 1800 (37.5) 180 (3.8) 75 (1.6) 1.5 (0.3) SLT-C30 500 2100 (20 83) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) SD-R15 1800 2000 (71 79) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) SD-LC25 2200 2100 (87 83) 1200 (25.0) Reported 1800 (37.5) 180 (3.8) 75 (1.6) 1.5 (0.3) SD-C30 2400 2100 (95 83) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) SD-HC40 3100 2400 (123 95) 1920 (40.0) L/175 2880 (60.0) 290 (6.0) 300 (6.2) 1.5 (0.3) SD-AW40 3100 2400 (123 95) 1920 (40.0) L/175 2880 (60.0) 390 (8.0) 300 (6.2) 1.5 (0.3) TH-C30 1200 1500 (48 60) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) TH-HC40 1200 1500 (48 60) 1920 (40.0) L/175 2880 (60.0) 290 (6.0) 300 (6.2) 1.5 (0.3) TH-AW40 1500 2500 (60 99) 1920 (40.0) L/175 2880 (60.0) 390 (8.0) 300 (6.2) 0.5 (0.1) TR-R15 1800 300 (71 12) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) TR-LC25 1800 400 (71 16) 1200 (25.0) Reported 1800 (37.5) 180 (3.8) 75 (1.6) 1.5 (0.3) TR-C30 2000 500 (79 20) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) TA-R15 1200 1600 (48 63) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) TA-LC25 1400 2500 (56 99) 1200 (25.0) Reported 1800 (37.5) 180 (3.8) 75 (1.6) 1.5 (0.3) TA-C30 1400 2500 (56 99) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) TA-R15 1200 600 (48 24) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) TA-LC25 1400 700 (56 28) 1200 (25.0) Reported 1800 (37.5) 180 (3.8) 75 (1.6) 1.5 (0.3) TA-C30 1400 700 (56 28) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) SKG/RW-R15 500 1100 (20 44) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) SKG/RW-C30 1100 1100 (44 44) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) SKG/RW-HC40 1100 2400 (44 95) 1920 (40.0) L/175 2880 (60.0) 290 (6.0) 300 (6.2) 1.5 (0.3) SKP/RW-R15 500 1100 (20 44) 720 (15.0) Reported 1080 (22.5) 140 (2.9) 75 (1.6) 1.5 (0.3) SKP/RW-C30 1100 1100 (44 44) 1440 (30.0) Reported 2160 (45.0) 220 (4.5) 75 (1.6) 1.5 (0.3) SKP/RW-HC40 1100 2400 (44 95) 1920 (40.0) L/175 2880 (60.0) 290 (6.0) 300 (6.2) 1.5 (0.3) TABLE 25 GATEWAY PERFORMANCE REQUIREMENTS

CMB-5-05 AAMA/WDMA/CSA 101/I.S.2/A440-05, EXCERPT Copyright 2005 American Architectural Manufacturers Association 1827 Walden Office Square, Suite 550 Schaumburg, IL 60143-4268 USA www.aamanet.org Window & Door Manufacturers Association 1400 East Touhy Avenue, Suite 470 Des Plaines, IL 60018 USA www.wdma.com Canadian Standards Association 5060 Spectrum Way, Suite 100 Mississauga, Ontario, L4W 5N6 Canada www.shopcsa.ca This document is an excerpt of AAMA/WDMA/CSA 101/I.S.2/A440-05. AAMA/WDMA/CSA 101/I.S.2/A440-05 was developed by representative members of AAMA, WDMA and CSA as advisory information and published as a public service. AAMA, WDMA and CSA disclaim all liability for the use, application or adaptation of materials published herein.