Technical Manual MDT Rain sensor



Similar documents
Inwall 4 Input / 4 Output Module

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

How To Use A Power Supply On A Powerline 2.2 (Ai)

ABB STOTZ-KONTAKT GmbH. ABB i-bus KNX Weather Unit, Weather Sensor

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

User Manual Weather station V 0.2

Push button 3gang standard flush-mounted xx

IntesisBox KNX Modbus TCP master

KNX Panasonic Air Conditioners

Inwall Room Temperature Unit

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

IntesisBox KNX Modbus RTU master

ABB i-bus EIB / KNX Weather Station WS/S 4.1

IntesisBox KNX Mitsubishi Heavy Industries AC

IntesisBox KNX - LON

ABB i-bus EIB Logic Module LM/S 1.1

IntesisBox KNX LG Air Conditioning

KNX L. Brightness Sensor. Installation and Adjustment. Item number 70119

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

Drayton Digistat +2RF/+3RF

Shutter Actuator, 8-fold, 230 V AC, MDRC JA/S , GH Q R0111. ABB i-bus EIB / KNX

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

KNX Gateway RGK E-01

KNX R. Rain Sensor. Installation and Adjustment

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Estação Meteorológica sem fio VEC-STA-003

EBDSPIR-PRM, EBDSPIR-PRM-IP

PRESENCE DETECTOR PD-C360i/24 KNX ECO (EP )

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Light scene push button 8gang comfort flush-mounted xx

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

KNX Lighting Control System

ELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB.

Tebis application software

Busch-Watchdog Presence EIB Type:

PSC-A5 Solar Charge Controller Manual

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Unica for KNX system 226

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Operating instructions II / 2004

SOLUTIONS FOR THE CONTROL OF THE WHOLE BUILDING

API Marine. BMS Presentation. Ballast Measurement Systems

Triple Waveband Infra-Red Flame Detection

Basics of Dimming. ISC Learning Centre

Climate Ready Shade Operating Systems for residential applications.

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Installation, operation and maintenance manual TX 35A

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Wind Sensor W-RS485 with RS485 Interface

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

DALIX PROGRAMMING MANUAL. Gateway KNX-DALI V1.0 TECHNICAL SUPPORT. Tel (+34)

Combi switchbox with integrated 3/2 way pilot valve

T0118 T2118 T3118. Instruction Manual

Instruction Manual Service Program ULTRA-PROG-IR

HERZ-Thermal Actuators

LED-INTA-0024V-41-F-O

ABB i-bus KNX SA/S Switch Actuators Product Manual

Transmitter Actuator 230V wave UP 560. Operation

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

USB-500 Series Low-Cost Data Loggers and Accessories

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145

EXTERNAL DIMENSIONS AND PARTS

ACS-30-EU-EMDR-10-MOD

Adaptability to Enhanced Security

Adaptability to Enhanced Security

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Operating instructions. RCD flat 4-fold, 6-fold

is then retained absolutely without interruption.

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Cable Plug acc. to DIN EN , Form A

Climate Ready Control Systems Technical Specifications

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

PROXIMITY CARD READERS C-10, C-20, C60, C70

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Transcription:

9/2012 Technical Manual MDT Rain sensor SCN-RS1R1.01

Technical Manual Rain sensor SCN RS1R1.01 1.1. Settings at the ETS Software Selection at the product database: Manufacturer: MDT Technologies Product family: Weather sensors Product type: Rain sensor Medium Type: Twisted Pair (TP) Product name: SCN RS1R1.01 Rain sensor Order number: SCN RS1R1.01 1.2 Starting Up After wiring the allocation of the physical address and the parameterization of every channel follow: (1) Connect the interface with the bus, e.g. MDT USB interface (2) Set bus power up (3) Activate the programming mode by closing the reed contact with the provided magnet red programming LED lights (4) Loading of the physical address (red LED goes out, as soon as this process was completed successfully) (5) Loading of the application (6) Switch the power supply on (7) If the device is enabled you can test the requested functions(also possible by using the ETS Software) 2 Parameterization The Rain Sensor SCN RS1R1.01 is used for the detection of rain and send messages if rain was detected. For faster drying after rain and at low temperatures, a heating is integrated below the sensor area. This enables also the detection of two contiguous rain periods. The following illustration shows the available settings of the rain sensor: 2

Technical Manual Rain sensor SCN RS1R1.01 The following chart shows the dynamic range for all parameters: ETS Text Dynamic range [default value] Startup timeout 1 60s [1s] cyclic send Operating telegram not active, 10min, 30min, 1h, 3h, 6h, 12h, 24h Send object rain only request at change cyclic at change and cyclic sensitivity of rain sensors low high Info object for heating is active no sending, only request send at changes Comment Time between programming and functional start of the device cyclic sending behavior, if sensor answers at the bus Sending behavior for the object rain defines the sensitivity of the detection threshold sending behavior for the state object, if heating is active at the moment The rain sensor contains of 5 adjustable parameters: Startup timeout The startup timeout defines the time between an application download and the functional start of the. cyclic send Operating telegram Via this parameter can be adjusted if an Operating telegram shall be sent and the time steps can be defined. The Operating telegram indicates at the adjusted cyclic distance if the sensor still answers at the bus. By activation and connecting this telegram, the error detection becomes much easier and helps finding broken devices instantly. The chart shows the relevant communication object: Number Name Function Length Usage 1 Operating Info 1 Bit Notification, if sensor answers at the bus Send object rain The sending behavior of the object 0 Rain can be defined via this parameter. The communication sends a logical 1 as soon as rain was measured and a logical 0 if no rain was measured. The chart shows the relevant communication object: Number Name Function Length Usage 0 Rain Message Rain Yes/No 1 Bit Output for detected rain 3

Technical Manual Rain sensor SCN RS1R1.01 Sensitivity of rain sensor If the rain sensor detects rain too early at the default value for the sensitivity (high), this can be adapted via this parameter. Info object for heating is active The info object for the heating indicates when the heating is active. Via this parameter can be adjusted, if the object for the heating shall report an active heating or send its state only on request. The heating is switched on at rain, so if the object 0 rain sends a logical 1, to speed up the drying process. Additional the heating will be switched on, if the temperature falls below 3 C. The temperature related cutoff is at 7 C. So, there is a hysteresis of 4 C. The chart shows the relevant communication object: Number Name Function Length Usage 2 Heating Message 1 Bit Notification, if the heating is Heating On/Off active 4

MDT Brightness/Weather N MDT Brightness-/Weather devices Version SCN-WS3HW.01 Weather Station Home Outdoor installation on wall or pole, flush mounted control unit SCN-SS1H.01 Sun Sensor Indoor installation with vacuum cup, flush mounted control unit SCN-RS1R.01 Rain Sensor Outdoor installation, Surface mounted MDT technologies offers three Brightness / Weather devices: Wetter Station Home: 3 channels for sun protection to control blind/shutter Sun protection up to 3 facades Offers wide functions to control facades (2 switching treshold, teach in function) Central shutter control for Up/Down via brightness value (with time delay) Brightness value for east, south, west, twilight Wind speed value, alarm if wind speed exceeds limit, temperature value Suited to control facades at home Installation on wall or pole, 5m connection cable No additional power supply required Integrated bus coupling unit Sun Sensor: Brightness sensor with vacuum for window installation 2 inputs to connect push button for blind control Hysteresis and time delay programmable 2m connection cable Flush mounted control unit Operation mode 1: Installation on window without blinds Operation mode 2: Installation on window with blinds No additional power supply required Integrated bus coupling unit in control unit Rain Sensor: Integrated, automatically heating Heating operation by choke free output STV-640 or external 24VDC power supply Current consumption of heating is <100mA 5m bus connection cable Stainless fastening angle included in delivery Dimensions (W x H x D): 67mm x 67mm x 29mm Integrated bus coupling unit For project design and commissioning of the Brightness/Weather devices it is recommended to use the ETS3f/ETS4 or later. Please download the application software at www.mdt.de/downloads.html SCN-SS1H.01 Production in Germany, certified according to ISO 9001 Modern design Fully compatible to all KNX/EIB devices Integrated bus coupling unit SCN-WS3HW.01 SCN-RS1R.01 Tel.: + 49-2263 - 880 Fax: + 49-2263 - 4588 knx@mdt.de www.mdt.de Stand: 1012 DIN EN ISO 9001 TAW Cert Zert.Nr.1905606

MDT Brightness/Weather N Technical Data SCN-SS1H.01 SCN-WS3HW.01 SCN-RS1R.01 Measured data Brightness Brightness, Wind, Twilight, Temperature Rain Permitted wire gauge KNX busconnection 0,8mm Ø, solid core 0,8mm Ø, solid core 0,8mm Ø, solid core Power supply KNX Bus KNX Bus KNX Bus Power consumption via KNX bus typ. < 0,3W < 0,3W < 0,3W* Operation temperature range 0 to + 45 C -20 to + 70 C 0 to + 45 C Enclosure IP 20 IP 44 IP 45 Dimensions control unit (W x H x D) 41mm x 41mm x 12mm -- 67mm x 67mm x 29mm * Without heating. Heating operation by choke free output STV 640 or external 24VDC power supply. Current consumption of heating is <100mA Examplary circuit diagram SCN-xSxxx.01 Examplary circuit diagram SCN-RS001.01 Tel.: + 49-2263 - 880 Fax: + 49-2263 - 4588 knx@mdt.de www.mdt.de Stand: 1012 DIN EN ISO 9001 TAW Cert Zert.Nr.1905606