0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3



Similar documents
3 Port Solenoid Valve

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

3 Port Solenoid Valve

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double

Single sub-base valve

5 Port Solenoid Valve

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

NAMUR Mount Hygienic Valve

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

4/2-Way Pneumatic Solenoid Valve

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Electro-pneumatic control valves

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

4 Posiflow Proportional Solenoid Valves

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Assisted lift operated 2/2-way solenoid valves Type EV250B

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Linear Luminaire with LED Series EXLUX 6402/2

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

G1/4 Q8. Standard with biased position

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Electro-Pneumatic Bus Door Control Mechanism

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

2/2 and 3/2 Way Size 6 Seat Valves

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

Chapter 6: Check Valves

Line-Mounted Valves L Series

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation

System 8. ü ( System 8

type V46, solenoid or pneumatic operated

3/2-way Solenoid Valve, direct-acting, NC or NO

Series M Applicable Tubing: ø2 Connection Thread: M3, M5

Valves. Sub-Base Mounted Valves to ISO 5599/2

SOLENOID VALVES 3-4 WAY

Unit 24: Applications of Pneumatics and Hydraulics

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Proportional pressure regulators VPPE

3/2-way Mini Solenoid Valve

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Valve systems Base plates, according to standard ISO Brochure

Control block VOFA with safety function

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

STC 3S A Series Solenoid Valves

For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } {175}

SQUARE D INDUSTRIAL CONTROL PRODUCTS

3/2- and 2/2-way cartridge valve type BVE

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

Solenoid valves Type EVU

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

zamak nitrile rubber self-extinguishing technopolymes aluminum

SOLENOID VALVES AND PNEUMATIC VALVES

Series VM. Mechanical Valves VM200. VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25

3/2 Solenoid Cartridge Valve, Size 6

Electro-hydraulic pressure switches type DG

Cable Plug acc. to DIN EN , Form A

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

size size

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

On-off valves MS-EM/EE, MS series, NPT

Table of Contents. MicroAir Series...3-9

IMPORTANT DOCUMENTATION DO NOT DISCARD!

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Solenoid Operated Directional Valves

Givare NC-SRS 280 och 880

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

VSO MAX HP High Flow Proportional Valve

Inductive sensor NI10-M18-Y1X-H1141

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

C 50 μm filtered air, with or without lubrication spool 10 bar G/18 G1/4 6,5 8,5 890

Vacuum Module: Series ZX Vacuum Ejector System/External Vacuum Supply System

servo-controlled 3-WaY vacuum solenoid valves WiTH

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

ISO /2 (VDMA 24563) ISO 02 (18 mm) - ISO 01 (26 mm) Valves

Solenoid Operated Directional Valves

Chapter 5: Flow Valves

Solenoid valves 2/2-way direct-operated Type EV210A

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Transcription:

Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00 00 00 Valve width (mm) 0 8 0 8 [Option] Flow characteristics Metal seal C [dm /(s. Rubber seal bar)] C [dm /(s. bar)] 0. (Poppet)..7..0.0 (Poppet).0.0.. 789

+ Metal Seal / Rubber Seal Port Solenoid Valve 00/00/00 Solenoid Valve Variations Sonic conductance C [dm /(sbar)] Type of actuation Voltage Light/Surge voltage Manual override 00 Metal Rubber (Poppet) 0. P.79 Body ported port 00 P.79 00 P.79 00 P.808..7..0 Metal Rubber (Poppet).0 (R) N.C. () () (P) (R) (P) N.O. (Except 00) (Standard) VDC VDC (Option) 00 VC 00 VC 0 VC 0 VC Grommet (G) L-type plug (L) +- M-type plug (M) -+ DIN terminal (Y) With light/surge voltage L-type plug (L) M-type plug (M) DIN terminal (YZ) Except 00 Non-locking push type (Tool required) Locking type (Tool required) Base mounted port 00 P.809.0.0 Except 00 00.. P.809 790

00/00/00 Manifold Body Ported 00 00 Base model V- V- Piping specifications Piping direction Bore size (P), (R) () Top Top Rc /8 Rc /8 C (for ø.) C (for ø) C (for ø) M (M thread) C (for ø) C (for ø) M (M thread) pplicable solenoid valve P.799 pplicable stations to 0 stations to 0 stations Manifold Options Body Ported Blanking plate assembly V00-0- (for 00) V00-0- (for 00) V00-0- (for 00) P.80 Blanking plug KP- KP-0 KP-0 KP-08 KP-0 P.80 DIN rail XT00-DR- P.80 Silencer (for EXH port) 00 V- Top Rc / C (for ø) C8 (for ø8) C0 (for ø0) Rc / to 0 stations P.80 Base Mounted P.8 Base Mounted Blanking plate assembly V00-0- (for 00) V00-0- (for 00) V00-0- (for 00) P.8 Blanking plug KP- KP-0 KP-0 KP-08 KP-0 P.8 DIN rail XT00-DR- 00 Base model V- Piping direction Side/ top Piping specifications Bore size (P), (R) () Rc /8 C (for ø.) C (for ø) C (for ø) M (M thread) pplicable solenoid valve pplicable stations to 0 stations P.8 Silencer (for EXH port) 00 00 V- V- Side Side Rc / (P) port Rc /8 (R) port Rc / C (for ø) C (for ø) C8 (for ø8) Rc /8 C (for ø) C8 (for ø8) C0 (for ø0) Rc / to 0 stations to 0 stations P.8 Port plug V00-CP (for 00) P.8 79

Body Ported Plug Lead Unit Port Solenoid Valve 00/00/00 Single Unit 00 / How to Order Valve [Option] Note) :DC type only. M C PR 00 body width 0 mm Type of actuation N.C. () (P) (R) Option : None F: With bracket Note) DC type only. Body type Bracket Function Symbol Specifications DC C Standard (0. W) Note ) Note ) K High pressure type R Note, ) External pilot type KR Note, ) High pressure/external pilot type Note ) Semi-standard Note ) For details on external pilot type, refer to page 80. Note ) For C specification power consumption, refer to page 79. Caution Use standard (DC) specification for continuous duty. : Non-locking push type Port size [() port] C ø. One-touch fitting C ø One-touch fitting C ø One-touch fitting M M thread (Replaceable type) Note) For inch size One-touch fittings, refer to page 80. B: Locking type (Tool required) Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC [ VC] (0/0 Hz) 0 VC [0 VC] (0/0 Hz) VDC VDC G: Grommet (DC specification) L: L-type plug with lead wire With light/ surge voltage LO: L-type plug without With light/ surge voltage M: M-type plug with lead wire With light/ surge voltage MO: M-type plug without With light/ surge voltage + + + + Note) Standard lead wire length: 00 mm Note) For applicable One-touch fitting and silencer models for this valve series, refer to page 88. 79

Body Ported 00/00/00 00/00 / How to Order Valve Note) C-type models that Made to Order are have (For details, refer to pages 79 and 8.) DIN terminals only. [Option] 00 body width mm 00 body width 8 mm Type of actuation N.C. () N.O. N.C. N.O. (R) (P) (R) (P) (R) () () () (P) (R) (P) Metal seal Rubber seal Body type Body ported M C IP compliant W Note) Compliant Note) 00/00 DIN terminal rubber seal only (except external pilot). For details on IP enclosure, refer to page 80. Note) C-type models that are have DIN terminals only. Option : None F: With bracket Port size [() port] Symbol Port size 00 00 C ø One-touch fitting C ø One-touch fitting C8 ø8 One-touch fitting C0 ø0 One-touch fitting M M thread 0 Rc / Note) For inch size One-touch fittings and option thread type, refer to page 80. : Non-locking push type B: Locking type (Tool required) (Tool required) +- Bracket Function Symbol Specifications DC C Standard (0. W) Note ) Note ) B High speed response type High pressure type K Note ) (Metal seal type only) R Note, ) External pilot type BR Note, ) High speed response/external pilot type KR Note, ) High pressure/external pilot type (Metal seal type only) Note ) Semi-standard Note ) For details on external pilot type, refer to page 80. Note ) For C specification power consumption, refer to page 79. Caution Use standard (DC) specification for continuous duty. Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC [ VC] (0/0 Hz) 0 VC [0 VC] (0/0 Hz) VDC VDC Note) For applicable One-touch fitting and silencer models for this valve series, refer to back page 88. (DC specification) CEcompliant CEcompliant C DC G: Grommet (DC specification) + Y: DIN terminal +- L: L-type plug with lead wire With light/ surge voltage +- +- LO: L-type plug without With light/ surge voltage YO: DIN YZ: DIN terminal terminal without With light/ surge voltage M: M-type plug with lead wire With light/ surge voltage YOS: DIN Note ) terminal without (DC specification) With surge voltage MO: M-type plug without With light/ surge voltage YS: DIN Note ) terminal With surge voltage C DC Note ) Standard lead wire length: 00 mm Note ) For C voltage valves there is no S type. It is already built-in to the rectifier circuit. + 79

00/00/00 Specifications Valve construction Fluid Metal seal Rubber seal ir, Inert gas 00 (Poppet seal) Max. operating pressure (MPa) 0.7 (High pressure type:.0) 0.7 0.7 (High pressure type:.0) Min. operating pressure (MPa) mbient and fluid temperature ( C) Max. operating frequency (Hz) Pilot exhaust method Lubrication 0. 0 0. 0 to 0 (No freezing) Individual exhaust Not required 0. 0 Common exhaust Mounting orientation Impact/Vibration resistance (m/s Note ) ) Enclosure Push type, Locking type (Tool required) Free 0/0 Dustproof (DIN terminal: IP Note ) ) Based on IEC09 Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between and 000 Hz. Test was performed to axis and right angle directions of the main valve and armature when pilot signal is ON and OFF. (Value in the initial state) Note ) When IP compliant DIN terminals are selected: -YW- Solenoid Specifications Semi-standard Specifications High speed response type High pressure type (Metal seal type only) External pilot type For details on external pilot type, refer to page 80. Made to Order (For details, refer to page 8.) Symbol Description X0 Pilot valve common exhaust X90 Main valve fluororubber X ll fluororubber Coil rated voltage (V) llowable voltage fluctuation Standard Power High speed consumption (W) DC response, high pressure 00 V pparent power (V) C Surge voltage Indicator light DC C 0/0 Hz 0 V [ V] 00 V 0 V [0 V] Grommet (G) L-type plug (L) In common between 0 VC and VC, and between 0 VC and 0 VC. For VC and 0 VC, the allowable voltage is % to +% of rated voltage. M-type plug (M) DIN terminal (Y) G, L, M Y, 00, 0, 00, 0 ±0% of rated voltage 0. [(With light: 0. (DIN terminal with light: 0.)] 0.9 [(With light: 0.9 (DIN terminal with light:.0)] 0.78 (With light: 0.8) 0.78 (With light: 0.87) 0.8 (With light: 0.89) [0.9 (With light: 0.97)] 0.8 (With light: 0.87) [0.9 (With light:.07)].8 (With light:.). (With light:.0).0 (With light:.) [. (With light:.)].7 (With light:.) [.9 (With light:.0)] Varistor LED (Neon light when C with DIN terminal) Flow Characteristics Valve construction Model 00 N.C. valve Poppet N.C. Metal seal 00 valve Rubber seal N.O. Metal seal N.C. valve Metal seal Rubber seal 00 valve Rubber seal N.O. Metal seal valve Rubber seal 0.9.....7... (P ) 0. 0. 0. 0. 0. 0.8 0. 0. 0.8 Flow characteristics 0.7 0.0 0.9 0. 0.0 0. 0.87 0.9 0.88 0...7..7..0..9 ( R) C [dm /(sbar)] b Cv C [dm /(sbar)] b Cv Note ) Based on JIS B 87-98 (Supply pressure: 0. MPa; with light/surge voltage : clean air) Response time values will change depending on pressure and air quality. Note ) Weight for threaded connection 79 0.0 0. 0.7 0.0 0. 0.8 0. 0. 0.7 Standard: 0. W Response time (ms) Note ) High speed response: 0.9 W High pressure: 0.9 W C 0. 0 or less or less or less 0. or less or less 8 or less or less 0. or less or less or less 0. or less or less 8 or less or less 0. or less or less or less 0. or less 7 or less or less or less 0.7 or less or less 7 or less 0.9 or less 7 or less or less or less 0.9 or less or less 7 or less Note ) Weight (g) 7 9

00/00/00 Construction 00 Poppet type N.C. () e w q (P) (R) Component Parts No. Description Body Spool valve Pilot valve assembly Material Resin luminum/hnbr Note r P, R port Resin/luminum 00- (Standard) 00-B (External pilot type) 00/00 Metal seal type Rubber seal type r e w q r e w q N.C. N.C. () () (R) (P) (R) (P) r e w q r e w q N.O. () (R) (P) N.O. () (R) (P) Component Parts No. Description Body Spool, Sleeve Spool valve Piston Pilot valve assembly Material Note luminum die-casted Stainless steel Metal seal luminum/hnbr Rubber seal Resin Note) For How to Order Pilot Valve ssembly, refer to page 807. 79

00/00/00 Dimensions: 00 Single Unit Grommet (G): -G-C, C, C-PR.8 () - + 8..8 One-touch fitting [() port] pplicable tubing O.D.: ø., ø/8" ø, ø/" ø, ø/" x ø. (For mounting).. 0 0 9.9 pprox. 00. 9. C: 9. N7:.9 (.)..8 With bracket Note) For bracket assembly part no., refer to page 807. Note) Tightening torque: 0. to 0. N m (X: External pilot port) <For external pilot> ø. (PE port) <For external pilot> 0.7 9 [ (P), (R) port] R P 0 x ø. (For mounting). 7 -G-M-PR [() port] ø. (PE port) 0. Note) For One-touch fittings for P/R port and silencer part no., refer to page 88. L-type plug (L): -L-C, C, C-PR M-type plug (M): -M-C, C, C-PR pprox. 00.8 [0.8] pprox. 00. [7.] 9.9 [.].9 9.7 [.9] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C 79

+ R P + Body Ported 00/00/00 Dimensions: 00 Single Unit Grommet (G): -G-C, C x ø. (For mounting) pprox. 00 9. 7 9. One-touch fitting [() port] pplicable tubing O.D.: ø, ø/" ø, ø/" 7. 9. M x 0. (External pilot port) <For external pilot> 0.. 8. -. x ø.7 (For manifold mounting) 8.8. 0 C:.7 N7:. (.) 8.. 7.8.. x ø. (For mounting) 8. 0. x M. x 0. Thread length With bracket /8 [(P) port] G/ [(R) port] x ø. die-cast hole (For manifold gasket positioning) Note) For bracket assembly part no., refer to page 807. ø.8 (PE port) ø. (Reverse-mounting-prevention hole ( models only). -G-M [() port] Note) For One-touch fittings for P/R port and silencer part no., refer to page 88. L-type plug (L): -L-C, C DIN terminal (Y): -Y-C, C pprox. 00 79 [8.] 8.8 [.8] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C M-type plug (M): -M-C, C 0. [7.] pprox. 00 9. [7.]. Max. 0 pplicable cable O.D. ø. to ø7..9. 7.9 Pg7 8. 8.. Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Unless otherwise indicated, dimensions are the same as Grommet (G). 797

+ P R 00/00/00 Dimensions: 00 Single Unit Grommet (G): -G-C, C8, C0 pprox. 00 7.8.8 One-touch fitting [() port] pplicable tubing O.D.: ø, ø/" ø8, ø/" ø0, ø/8" x ø. (For manifold mounting) x ø. (For mounting) 8. 0 8. (External pilot port) <For external pilot> 8. 7. (.) 78. +. x ø. (For mounting) ø.8 (PE port) /8 [(R) port] x ø die-cast hole (For manifold gasket positioning).9.7...7 9. 8 / [(P) port] 0. ø. (Reverse-mountingprevention hole ( models only). x M. x 0. Thread length -G-0 8.8 / [() port] 8.. With bracket Note) For bracket assembly part no., refer to page 807. L-type plug (L): -L-C, C8, C0 DIN terminal (Y): -Y-C, C8, C0 pprox. 00 8.8 [88] [9] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Max. 0 pplicable cable O.D. ø. to ø7 Pg7 9.7.8 M-type plug (M): -M-C, C8, C0 pprox. 00 7 [78.] 7..8.. 9.. [0.] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Unless otherwise indicated, dimensions are the same as Grommet (G). 798

Body Ported Plug Lead Unit Port Solenoid Valve 00/00/00 Manifold Connector Kit 00 / How to Order Manifold [Option] Note) For models, DC type only. V 08 00 Manifold type Body ported Stations 0 stations 0 0 stations C Kit type C Connector D 00 / How to Order Valve Option None D DIN rail mounting (With standard DIN rail length) D0 Note ) DIN rail mounting (Without DIN rail) R Note ) External pilot type Note ) Order DIN rail separately. For DIN rail part no., refer to page 80. Note ) When two or more symbols are specified, indicate them alphabetically. Note) For (P), (R) of optional thread type, refer to page 80. M 00 body width 0 mm Type of actuation N.C. Body type Function Symbol Specifications DC C Standard (0. W) Note ) K Note ) High pressure type Note, ) R External pilot type KR Note, ) High pressure/external pilot type Note ) Semi-standard Note ) For details on external pilot type, refer to page 80. Note ) For C specification power consumption, refer to page 79. Caution Use standard (DC) specification for continuous duty. Non-locking push type B Locking type (Tool required) Symbol G L LO M MO C With light/surge voltage Grommet (DC specification) None L-type plug with lead wire L-type plug without Yes M-type plug with lead wire M-type plug without Note) Standard lead wire length: 00 mm Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC [ VC] (0/0 Hz) 0 VC [0 VC] (0/0 Hz) VDC VDC Note) For models, DC type only. Port size [() port] C ø. One-touch fitting C ø One-touch fitting C ø One-touch fitting M M thread (Replaceable type) Note) For inch size One-touch fittings, refer to page 80. 799

00/00/00 00/00 / How to Order Manifold Made to Order (For details, refer to page 8.) Note) C-type models that are have DIN terminals only. [Option] V 08 C 00 00 Manifold type Body ported Stations 0 stations 0 0 stations Kit type C Connector Option None D DIN rail mounting (With standard DIN rail length) D0 Note) DIN rail mounting (Without DIN rail) Note) Order DIN rail separately. For DIN rail part no., refer to page 80. Note) For (P), (R) of optional thread type, refer to page 80. 00/00 / How to Order Valve M 00 body width mm 00 body width 8 mm Type of actuation N.C. Metal seal N.O. Metal seal N.C. Rubber seal N.O. Rubber seal Body type Body ported Function Symbol Specifications DC C Standard (0. W) Note ) Note ) B High speed response type High pressure type K Note ) (Metal seal type only) R Note, ) External pilot type BR Note, ) High speed response/external pilot type KR Note, ) High pressure/external pilot type (Metal seal type only) Note ) Semi-standard Note ) For details on external pilot type, refer to page 80. Note ) For C specification power consumption, refer to page 79. Caution Use standard (DC) specification for continuous duty. 800 Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC [ VC] (0/0 Hz) 0 VC [0 VC] (0/0 Hz) VDC VDC Port size [() port] Symbol Port size C ø One-touch fitting C ø One-touch fitting C8 ø8 One-touch fitting C0 ø0 One-touch fitting M M thread 0 Rc / Non-locking push type (Tool required) B Locking type (Tool required) Symbol G L LO M MO Y YO YZ YS YOS IP compliant W Note) Compliant Note) 00/00 DIN terminal rubber seal only (except external pilot). For details on IP enclosure, refer to page 80. 00 00 Note) For inch size One-touch fittings and optional thread type, refer to page 80. Grommet (DC specification) L-type plug with lead wire L-type plug without M-type plug with lead wire M-type plug without DIN terminal DIN terminal without DIN terminal DIN terminal (DC specification) Note) C-type models that are have DIN terminals only. Light/surge voltage None Yes None Yes Note ) Yes (Without light) Note ) DIN terminal without (DC specification) C DC Note ) Standard lead wire length: 00 mm Note ) For C voltage valves there is no S type. It is already built-in to the rectifier circuit.

Body Ported 00/00/00 Manifold Specifications Base model Piping specifications Piping Port size direction (P), (R) () pplicable Manifold pplicable solenoid base stations valve weight (g) C (for ø.) 00 V- Top Rc /8 C (for ø) C (for ø) to 0 stations M (M thread) C (for ø) 00 V- Top Rc /8 C (for ø) to 0 M (M thread) stations C (for ø) C8 (for ø8) 00 V- Top Rc / to 0 C0 (for ø0) stations Rc / stations: 8 ddition per station: 9 stations: 8 ddition per station: 0 stations: ddition per station: 7 How to Order Manifold ssembly (Example) D side Stations U side V-0C V00-0- -M-C set (C kit -station manifold base part no.) set (Blanking plate assembly part no.) sets (N.C. type part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Enter in order starting from the first station on the D side. dd the valve and option part number under the manifold base part number. When entry of part numbers becomes complicated, indicate by the manifold specification sheet. 80

00/00/00 Dimensions: 00 V- Stations C Grommet (G) U side D side One-touch fitting [() port] pplicable tubing O.D.: ø., ø/8" ø, ø/" ø, ø/" x ø. (For mounting) (8) L L L. [() port] (.) C:. N7: 7.9 8 /8 [(P), (R) port]. () (.) P R P R 9...9 9.... () - + - + - + - + pprox. 00 (Station n) (Station ). 70. [77.] 9. [.] () 0 - + (.) (DIN rail) (DIN rail clamp thread).. (Pitch) P = 0.. L (Rail mounting hole pitch:.) L () x (X: External pilot port) <For external pilot>.9 (PE: Pilot EXH port) M The dashed lines indicate the DIN rail mounting [-D]. (7.) L-type plug (L) M-type plug (M) pprox. 00 9.9.9 [7.] pprox. 00.7 [.9] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Dimensions L n L L L L L 8. 7. 0. 8. 7 80 98 87.. 7. 0. 00 7 8. 8. 9 7. 7. 9 0 8 8 8 7. 0. 9. 9 8 7. 7. 0 0 0. 0 7... 7. 8 7. Formula: L = 0.n + 9. L = 0.n +. n: Stations (Max. 0 stations) 7 8 9 0 8. 98 0. 0.. 8 0. 7 7 87. 00 00. 7. 0. 8. 9 9. 80 90. 0.. 8. 9. 0... 7. 8. 9. 0... 7 77. 88 98. 09 9.

R P Body Ported 00/00/00 Dimensions: 00 V- Stations C Grommet (G) U side One-touch fitting [() port] pplicable tubing O.D.: ø, ø/" ø, ø/" (8) () (.) 9. P R D side [() port] L L x ø. L. (For mounting) (0.) 7. 7. (For M) /8 [(P),(R) port] 7. 7.8 8. (0) () (DIN rail) (DIN rail clamp thread) M x 0. (External pilot port) <For external pilot>. (Pitch) P = 9 L (Rail mounting hole pitch:.) L () pprox. 00 9. PE port 7. (Station n) (Station ) C: 0. N7: (.) - + - + - + - + - + (7.) 8 ().9 The dashed lines indicate the DIN rail mounting [-D]. L-type plug (L) M-type plug (M) DIN terminal (Y) 79 [8.] pprox. 00 Dimensions L n L L L L L 8. 7 7. [.] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C 0. 00 70 0. 9. 8 8. 7. 0 7 9 8 7. 8 07 9. [7.]. pprox. 00 7 7. 9. 8 8. 7 0 8 9 9 98 87. 8. [.] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C 0. 8 0. 7. 98 9 87 8 7. 7 0 8. Max. 0 Pg7.. 7. 79.9. pplicable cable O.D. ø. to ø7 Unless otherwise indicated, dimensions are the same as Grommet (G). Formula: L = n + L = n + n: Stations (Max. 0 stations) 7 8 9 0 0. 8. 98 0.. 8 0. 7 0 7 87. 00 7. 0. 0 78 9 0. 0 8. 9 7.. 9 7 8 99 8. 80

L L L (Station n) (Station ) - + - + - +. 00/00/00 Dimensions: 00 V- Stations Grommet (G) U side One-touch fitting [() port] pplicable tubing O.D.: ø, ø/" ø8, ø/" (8) ø0, ø/8" () C (.) (DIN rail) P R P R D side / [() port] x ø. (For mounting) (.) 0...8.8 7 9 / [(P), (R) port] 0 () (DIN rail clamp thread) (External pilot port) <For external pilot> (Pitch) P = 9 L (Rail mounting hole pitch:.) L () pprox. 00 PE port. (.) 7. - + - + (For /) (7.) () The dashed lines indicate the DIN rail mounting [-D]. L-type plug (L) M-type plug (M) DIN terminal (Y) 8.8 [88] pprox. 00 Dimensions L n L L L L L 98 87. 8. 9 80. [.] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C 0. 00 80. 8. 99 8. 87 8 7. 8 0 7. 7 8 7 [78.] 7 pprox. 00 7 98 87. 8 0. 00 7 8 9. 9 8 7.8 [7.8] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C 0 8 7. 7. 0 7. 0. 0 8. 7 7. 9 Max. 0 9.7.8 Pg7 7.9 7 78. 8.8 pplicable cable O.D. ø. to ø7 Unless otherwise indicated, dimensions are the same as Grommet (G). Formula: L = 9n + L = 9n + n: Stations (Max. 0 stations) 7 8 9 0 0. 8 0. 8. 98. 00. 7. 0 7 87.. 70 89 08 7 8 0 0. 7 0 7 0. 9.. 8 77 9 7 9 9.

Body Ported 00/00/00 Manifold Options Blanking plate assembly V00-0- (for 00) V00-0- (for 00) V00-0- (for 00) It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. Blanking plug KP- KP-0 KP-0 KP-08 KP-0 L ød Dimensions pplicable Model fitting size ød. 8 0 KP- KP-0 KP-0 KP-08 KP-0 (mm) L D 8 0.. 9 8 0 DIN rail XT00-DR- L 7. s for, enter the number from the DIN rail dimensions table. For L dimension, refer to the dimensions of each kit. () () Each manifold can be mounted on a DIN rail. Insert D at the end of the manifold part number. The DIN rail is approximately 0 mm longer than the length of manifold. L Dimension No. L dimension No. L dimension. 8 0. 7 8. 7 8. 98 0.. 7 8 9 0 98 0.. 8 0. 7 7 8 9 0 8 0. 7 8. 98 0. 8. 98. 8 0. 0. L =.n + 0. 7 8 9 0. 8 0. 7 8 9 0 7 8. 98 0. Silencer (for manifold EXH port) Silencer is installed in the manifold EXH port. ø N0-0 N0-0 ø. Dimensions Model Silencer part no. 00 N0-0 00 N0-0 00 N0-0 For a silencer to be mounted in a single valve unit, refer to page 88. 80

Body Ported Semi-standard Specifications [Option] External Pilot Specification The external pilot specification is used when the operating pressure is below the minimum operating pressure 0. to 0. MPa or when valve is used for a vacuum application. Order a valve by adding the external pilot specification [R] to the part number. Valve Part No. R Entry is the same as standard products. Inch Size One-touch Fittings and Optional Threads Inch size One-touch fittings and NPT, NPTF and G thread are available. Valve Part No. External pilot port M x 0. (00) (00) Entry is the same as standard products. Cylinder port Symbol N N N7 N9 N M 0 pplicable tubing O.D. (Inch) ø/8" ø/" ø/" ø/" ø/8" M thread / thread 00 () port 00 00 Note) Metric size One-touch fittings (C) are also available. N7 T Pressure Specifications External pilot pressure range Note ) Metal seal Rubber seal (00: poppet) 00 Note ) 00/00 0. to 0.7 MPa 0. to 0.7 MPa 0. to 0.7 MPa Operating pressure range Note ) 00 kpa to 0.7 MPa Note ) In case of the high pressure type, upper limit of max. operating pressure and external pilot pressure range is MPa. Note ) Pump down from (P) port when 00 series vacuum type is specified. pply pressure from (R) port to relieve vacuum pressure. Set the release pressure at 0% of external pilot pressure or less. In addition, when the 00 is to be used at an operating pressure greater than 0. MPa, please assure that the operating pressure is set to equal to or less than the external pilot pressure. Thread type (Cylinder port and (P), (R) ports) Rc N NPT T NPTF F G Note ) (R) port of the 00 is only G/. Note ) Except 00 Manifold Part No. V C D 00T Entry is the same as standard products. IP Enclosure (Based on IEC09) Note) The pilot exhaust IP valves is common with main valve exhaust. (The standard valve has an individual exhaust for the pilot valve.) DIN terminal is available with IP enclosure. Valve Part No. (pplicable to the 00/00 rubber seal with the exception of the external pilot type) Y W 80 Entry is the same as standard products. Thread type ((P), (R) ports) Rc 00N NPT 00T NPTF 00F G

Body Ported Replacement Parts One-touch Fitting ssembly (for Cylinder port) Fitting size Model 00/00 00 C C C C8 C0 VV000-0-C VV000-0-C Note) Purchasing order is available in units of 0 pieces. VV000-0-C VV000--C VV000--C8 VV000--C0 M (00 only) VV000-0-M <Plug assembly> DC: SY00-0-- 00 VC: SY00-0-- 00 VC: SY00-0-- Other C voltages: SY00-0-- Without lead wire: SY00-0- (with and sockets only) <Gasket and screw assembly> Model Part no. 00 00-GS- 00 00-GS- 00 00-GS- Note) bove part number consists of 0 units. Each unit has one gasket and two screws. Purchasing Symbol Specifications DC order is available in units of 0 pieces. Standard (0. W) B Note) High speed response type <Bracket assembly> Lead wire length 00 mm 0 0 0 0 00 mm 000 mm 00 mm 000 mm 00 mm 000 mm 000 mm How to Order Include the assembly part number together with the part number for the plug s solenoid valve without. Example) In case of 000 mm of lead wire DC -LO-M-PR SY00-0--0 C -LO-M-PR SY00-0--0 Model Part no. Tightening torque (N m) Note) 00 00 00 00-FB 00-FB 00-FB 0. to 0. Note) Tightening torque when mounting a bracket on the valve. <Pilot valve assembly> M V Function Symbol Specifications DC C Standard (0. W) B Note) High speed response type (pplicable to 00/00) K Note) High pressure type (pplicable to Metal seal type, Poppet seal type) Note) Semi-standard None (pplicable to 00/00) Yes (pplicable to 00) V G <DIN terminal type (pplicable to the 00/00)> High pressure type K Note) (Metal seal type only) Note) Semi-standard Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC (0/0 Hz) 0 VC (0/0 Hz) VDC VDC Symbol Y YO YZ YS Note) Symbol DC C G LU LOU MU LZ LOZ MZ Valve model -L -M Function C Y Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC (0/0 Hz) 0 VC (0/0 Hz) VDC VDC Grommet (DC specification) L-type plug with lead wire L-type plug without M-type plug with lead wire MOU MOZ M-type plug without Note) pilot valve electrical entry (L, M) is the opposite of the how to order of valve body. Pilot valve model VM-M VM-L (pplicable to the 00) X0 Non-locking push type Locking slotted type DIN terminal DIN terminal without DIN terminal with light/surge voltage DIN terminal with surge voltage (DC specification) DIN terminal with surge voltage, without (DC specification) Light/surge voltage None Light/surge voltage None Yes Yes YOS Note) (Without light) Note) For C voltage valves there is no S type. It is already built-in to the rectifier circuit. Caution When replacing only the pilot valve assembly, use caution because it is not possible to convert to a V (DIN terminal) from a V (Grommet, L-type, M-type), or vice versa. B Yes 807

(P) Base Mounted Plug Lead Unit Port Solenoid Valve 00/00/00 Single Unit 00 / How to Order Valve [Option] Note) For models, DC type only. M 0 00 body width 0 mm Type of actuation () N.C. (R) Body type Base mounted Function Symbol Specifications DC C Standard (0. W) Note ) K Note ) High pressure type Note, ) R External pilot type KR Note, ) High pressure/external pilot type Note ) Semi-standard Note ) For details on external pilot type, refer to page 8. Note ) For C specification power consumption, refer to page 80. Caution Use standard (DC) specification for continuous duty. : Non-locking push type G: Grommet (DC specification) L: L-type plug with lead wire With light/ surge voltage Port size [() port] CP Without sub-plate 0 Rc /8 B: Locking type (Tool required) Note) For optional thread type, refer to page 8. LO: L-type plug without With light/ surge voltage Note) For models, DC type only. M: M-type plug with lead wire With light/ surge voltage MO: M-type plug without With light/ surge voltage + - + - - + +- Note) Standard lead wire length: 00 mm Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC [ VC] (0/0 Hz) 0 VC [0 VC] (0/0 Hz) VDC VDC Note) For sub-plate part no., refer to page 8. 808

Base Mounted 00/00/00 00/00 / How to Order Valve Made to Order (For details, refer to pages 80 and 8.) Note) C-type models that are have DIN terminals only. [Option] M 00 body width mm 00 body width 8 mm Type of actuation N.C. () N.O. N.C. N.O. (R) (R) () () (P) (R) (P) () (P) Metal seal Rubber seal IP compliant W Note) Compliant Note) 00/00 DIN terminal rubber seal only (except external pilot). For details on IP enclosure, refer to page 8. Port size [() port] Symbol Port size Without sub-plate 0 Rc /8 0 Rc / 0 Rc /8 : Non-locking B: Locking type push type (Tool required) (Tool required) Note) C-type models that are have DIN terminals only. 00 00 Note) For optional thread type, refer to page 8. (R) (P) +- +- Body type Body mounted Function Symbol Specifications DC C Standard (0. W) Note ) B Note ) High speed response type High pressure type K Note ) (Metal seal type only) R Note, ) External pilot type High speed response/external BR Note, ) pilot type KR Note, ) High pressure/external pilot type (Metal seal type only) Note ) Semi-standard Note ) For details on external pilot type, refer to page 8. Note ) For C specification power consumption, refer to page 80. Caution Use standard (DC) specification for continuous duty. (DC specification) CEcompliant CEcompliant C DC G: Grommet (DC specification) + Y: DIN terminal L: L-type plug with lead wire With light/ surge voltage Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC [ VC] (0/0 Hz) 0 VC [0 VC] (0/0 Hz) VDC VDC +- LO: L-type plug without With light/ surge voltage YO: DIN YZ: DIN terminal terminal without With light/ surge voltage M: M-type plug with lead wire With light/ surge voltage YOS: DIN Note ) terminal without (DC specification) With surge voltage MO: M-type plug without With light/ surge voltage YS: DIN Note ) terminal With surge voltage C DC Note ) Standard lead wire length: 00 mm Note ) For C voltage valves there is no S type. It is already built-in to the rectifier circuit. + Note) For sub-plate part no., refer to page 8. 809

00/00/00 Specifications Valve construction Fluid Metal seal Rubber seal ir, Inert gas 00 (Poppet seal) Max. operating pressure (MPa) 0.7 (High pressure type:.0) 0.7 0.7 (High pressure type:.0) Min. operating pressure (MPa) mbient and fluid temperature ( C) Max. operating frequency (Hz) Pilot exhaust method Lubrication 0. 0 0. 0 to 0 (No freezing) Individual exhaust Not required 0. 0 Common exhaust Mounting orientation Impact/Vibration resistance (m/s ) Note ) Enclosure Push type, Locking type (Tool required) Free 0/0 Dustproof (DIN terminal: IP Note ) ) Based on IEC09 Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between and 000 Hz. Test was performed to axis and right angle directions of the main valve and armature when pilot signal is ON and OFF. (Value in the initial state) Note ) When IP compliant DIN terminals are selected: -YW-- Solenoid Specifications Semi-standard Specifications High speed response type High pressure type (Metal seal type only) External pilot type For details on external pilot type, refer to page 8. Made to Order (For details, refer to page 8.) Symbol Description X0 Pilot valve common exhaust X90 Main valve fluororubber X ll fluororubber Coil rated voltage (V) llowable voltage fluctuation Standard Power DC High speed consumption (W) response, high pressure 00 V pparent power (V) C Surge voltage Indicator light DC C 0/0 Hz 0 V [ V] 00 V 0 V [0 V] Grommet (G) L-type plug (L) In common between 0 VC and VC, and between 0 VC and 0 VC. For VC and 0 VC, the allowable voltage is % to +% of rated voltage. M-type plug (M) DIN terminal (Y) G, L, M Y, 00, 0, 00, 0 ±0% of rated voltage 0. [(With light: 0. (DIN terminal with light: 0.)] 0.9 [(With light: 0.9 (DIN terminal with light:.0)] 0.78 (With light: 0.8) 0.78 (With light: 0.87) 0.8 (With light: 0.89) [0.9 (With light: 0.97)] 0.8 (With light: 0.87) [0.9 (With light:.07)].8 (With light:.). (With light:.0).0 (With light:.) [. (With light:.)].7 (With light:.) [.9 (With light:.0)] Varistor LED (Neon light when C with DIN terminal) Flow Characteristics 00 00 00 Valve construction Model N.C. valve Poppet N.C. Metal seal valve Rubber seal N.O. Metal seal valve Rubber seal N.C. Metal seal valve Rubber seal N.O. Metal seal valve Rubber seal (P ) Flow characteristics ( R) C [dm /(sbar)] b Cv C [dm /(sbar)] b Cv 0.87.7..7..0..9. 0. 0.7 0. 0.8 0. 0. 0. 0. 0. 0. 0.8 0. 0.8 0.7 0.70. 0.7..0.0.0.8.0...9. Note ) Based on JIS B 87-98 (Supply pressure: 0. MPa; with light/surge voltage : clean air) Response time values will change depending on pressure and air quality. Note ) Weight without sub-plate. 80 0. 0.0 0.0 0. 0.0 0.7 0. 0. 0.8 Standard: 0. W Response time (ms) Note ) High speed response: 0.9 W High pressure: 0.9 W C 0. 0 or less or less or less 0. or less or less 8 or less or less 0.80 or less or less or less 0.9 or less or less 8 or less or less 0.7 or less or less or less 0.80 or less 7 or less or less or less.0 or less or less 7 or less 0.9 or less 7 or less or less or less. or less or less 7 or less Note ) Weight (g) 78

Base Mounted 00/00/00 Construction 00 Poppet type e r w q N.C. () (P) (R) Component Parts No. Description Body Spool valve Pilot valve assembly Port plug Material Resin luminum/hnbr Resin/HNBR Note V00-CP 00/00 Metal seal type Rubber seal type r e w q r e w q N.C. () N.C. () (R) (P) (R) (P) r e w q r e w q N.O. () (R) (P) N.O. () (R) (P) Component Parts No. Description Body Spool, Sleeve Spool valve Piston Pilot valve assembly Material luminum die-casted Stainless steel luminum/hnbr Resin Note Metal seal Rubber seal Note) For How to Order Pilot Valve ssembly, refer to page 8. 8

00/00/00 Dimensions: 00 Single Unit Grommet (G): -G-0 (X: External pilot port) (For external pilot).. /8 [() port] pprox. 00 pprox. 00.8 [0.8] pprox. 00. [7.] 0.9 [.].9 0.7 [.9] 7. 7. x ø. (For mounting).. PE - + P R.8 8. 0.9 0.. (PE port) /8 [(P), (R) port]. 7 7. L-type plug (L): -L-0 M-type plug (M): -M-0 Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C 8 Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C

Base Mounted 00/00/00 Dimensions: 00 Single Unit Grommet (G): -G- 0 0 /8, / [() port] 9. 9 x ø. (For mounting) pprox. 00 - +. 9 X 9.8 PE port 9 R P 0 0. 7 9. (External pilot port) <External pilot only> /8, / [(P), (R) port] 8 (7) 0 (0.) ( ): -G-0 L-type plug (L): -L- 0 0 DIN terminal (Y): -Y- 0 0 pprox. 00 79 [8.] 9.8[.8] Max. 0 8. pplicable cable O.D. ø. to ø7 Pg7. Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C M-type plug (M): -M-. [8.] pprox. 00 9. [7.]. 0 0 8. 7.9. 8. 8.9 Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C 8

00/00/00 Dimensions: 00 Single Unit Grommet (G): -G- 0 0 /, /8 [() port].. 9 x ø. (For mounting) 7 R P pprox. 00. 7. - +. 0. X 7 PE port... (External pilot port) <External pilot only> /, /8 [(P), (R) port] (9) 7 () ( ): -G-0 L-type plug (L): -L- 0 0 DIN terminal (Y): -Y- 0 0 pprox. 00 8. [88.] 7 [] Max. 0 pplicable cable O.D. ø. to ø7 Pg7 9. Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C M-type plug (M): -M- 0 0 8. 78.8 7. 8. 8. [7.] pprox. 00 7. [78.] 7. 9.9 Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Unless otherwise indicated, dimensions are the same as Grommet (G). 8

Base Mounted Plug Lead Unit Port Solenoid Valve 00/00/00 Manifold Connector Kit 00 / How to Order Manifold [Option] Note) For models, DC-type only. 00 Stations 0 stations 0 0 stations V C C C M CP CM Note ) Note ) Manifold type Base mounted ø. One-touch fitting ø One-touch fitting ø One-touch fitting M thread (Replaceable type) With port plug Mixed port sizes 08 C Port size [() port] For side ported For top ported C Note ) When CP port plug is attached on all () port. Valve on manifold is top ported. Note ) Specify the mixture port (including top and side piping) by the manifold specification sheet. Note ) For inch size One-touch fittings, refer to page 8. Option None D DIN rail mounting (With standard DIN rail length) D0 Note) DIN rail mounting (Without DIN rail) R External pilot type Note ) Order DIN rail separately. For DIN rail part no., refer to page 8. Note ) When two or more symbols are specified, indicate them alphabetically. Kit type C Connector 00 / How to Order Valve M 00 body width 0 mm Type of actuation N.C. Body type Base mouned Function Symbol Specifications DC C Standard (0. W) K Note ) High pressure type Note, ) R External pilot type Note, ) KR High pressure/external pilot type Note ) Semi-standard Note ) For details on external pilot type, refer to page 8. Note ) For C specification power consumption, refer to page 80. Caution Use standard (DC) specification for continuous duty. Note ) Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC [ VC] (0/0 Hz) 0 VC [0 VC] (0/0 Hz) VDC VDC C Note) For models, DC type only. Port size CP With port plug For side ported C ø. One-touch fitting C ø One-touch fitting C ø One-touch fitting For top ported M M thread Note) For inch size One-touch fittings, refer to page 8. Non-locking push type (Tool required) B Locking type (Tool required) Symbol G L LO M MO Light/surge voltage Grommet (DC specification) None L-plug plug with lead wire L-plug plug without Yes M-plug plug with lead wire M-plug plug without Note) Standard lead wire length: 00 mm 8

00/00/00 00/00 / How to Order Manifold Made to Order (For details, refer to page 8.) Note) C-type models that are have DIN terminals only. [Option] 00 00 Symbol C C C8 C0 0 0 CM V Note ) Manifold type Base mounted Stations 0 stations 0 0 stations 08 C Port size [() port] Port size 00 00 ø One-touch fitting ø One-touch fitting ø8 One-touch fitting ø0 One-touch fitting Rc /8 Rc / Mixed port sizes Note ) Specify port mixture/with port plug by means of the manifold specification sheet. Port mixture and port plug are available only for one-touch fitting type. Note ) For inch size One-touch fittings, refer to page 8. C Kit type C Connector Option None D DIN rail mounting (With standard DIN rail length) D0 Note) DIN rail mounting (Without DIN rail) R External pilot type Note ) Order DIN rail separately. For DIN rail part no., refer to page 8. Note ) When two or more symbols are specified, indicate them alphabetically. 00/00 / How to Order Valve M 00 body width mm 00 body width 8 mm Type of actuation N.C. Metal seal N.O. Metal seal N.C. Rubber seal N.O. Rubber seal Caution Use standard (DC) specification for continuous duty. Body type Base mouned Function Symbol Specifications DC C Standard (0. W) Note ) Note ) B High speed response type High pressure type K Note ) (Metal seal type only) Note, ) R External pilot type BR Note, ) High speed response/external pilot type High pressure/external pilot type KR Note, ) (Metal seal type only) Note ) Semi-standard Note ) For details on external pilot type, refer to page 8. Note ) For C specification power consumption, refer to page 80. 8 Non-locking push type (Tool required) B Locking type (Tool required) Symbol G L LO M MO Y YO YZ YS YOS Note ) Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC [ VC] (0/0 Hz) 0 VC [0 VC] (0/0 Hz) VDC VDC Note) C-type models that are have DIN terminals only. Grommet (DC specification) L-type plug with lead wire L-type plug without M-type plug with lead wire M-type plug without DIN terminal DIN terminal without DIN terminal DIN terminal (DC specification) Note ) DIN terminal without (DC specification) IP compliant W Note) Compliant Note) 00/00 DIN terminal rubber seal only (except external pilot). For details on IP enclosure, refer to page 8. Light/surge voltage None Yes None Yes Yes (Without light) C DC Note ) Standard lead wire length: 00 mm Note ) For C voltage valves there is no S type. It is already built-in to the rectifier circuit.

Base Mounted 00/00/00 Manifold Specifications 00 Base model V- Piping specifications Piping Port size direction (P), (R) () Side/Top Rc /8 C (for ø.) C (for ø) C (for ø) M (M thread) Note) pplicable pplicable Manifold solenoid stations base valve weight (g) to 0 stations stations: 8 ddition per station: 9 00 V- Side Rc / C (for ø) C (for ø) C8 (for ø8) Rc /8 to 0 stations stations: ddition per station: 8 00 V- Side (P) port C (for ø) Rc /8 C8 (for ø8) (R) port C0 (for ø0) Rc / Rc / to 0 stations stations: 09 ddition per station: 0 Note) Weight for threaded connection. How to Order Manifold ssembly (Example) Stations U side -L sets D side V-0CC V00-0- -L set (C kit -station manifold base part no.) set (Blanking plate assembly part no.) sets (N.C. type part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Enter in order starting from the first station on the D side. dd the valve and option part number under the manifold base part number. When entry of part numbers becomes complicated, indicate by the manifold specification sheet. C: One-touch fitting for ø V00-0- 87

P Grommet (G) D side L U side (). L (Rail mounting hole pitch:.) (Pitch). P = 0.. (DIN rail) pprox. 00 (PE: Pilot EXH port).9 (Station ) (Station n) 9. 8. (For M) 0 () 00/00/00 Dimensions: 00: Top Ported V- Stations Port size C (X: External pilot port) <For external pilot> (DIN rail clamp thread) (.) - + - + - + - + - + 9..9. 9. x ø. (For mounting) [() port]. L P R L L R (8) (.) () One-touch fitting [() port] pplicable tubing O.D.: ø., ø/8" ø, ø/" ø, ø/".... () /8 [(P), (R) port] C:. N7: 7.9 (.) (7.) The dashed lines indicate the DIN rail mounting [-D]. M pprox. 00.9 () (PE: Pilot EXH port).... PE (). 8 /8 [(P), (R) port] Dimensions L n L L L L L 8. 7. 0. 8. 7 88 98 87.. 7. 0. 00 7 8. 8. 9 7. 7. 9 0 8 8 8 7. 0. 9. 9 8 7. 7. 0 0 0. 0 7... 7. 8 7. Formula: L = 0.n + 9. L = 0.n +. n: Stations (Max. 0 stations) 7 8 9 0 8. 98 0. 0.. 8 0. 7 7 87. 00 00. 7. 0. 8. 9 9. 80 90. 0.. 8. 9. 0... 7. 8. 9. 0... 7 77. 88 98. 09 9.

P (). L L (Rail mounting hole pitch:.) (Pitch). P = 0.. (DIN rail clamp thread) pprox. 00.9 (PE: Pilot EXH port) (.) - + (DIN rail). 9. 9..9 R (.) ().... () Base Mounted 00/00/00 Dimensions: 00: Side Ported V- Stations Port size C Grommet (G) (X: External pilot port) <For external pilot> D side U side - + - + - + - + P R.7 (For M) x ø. (For mounting). L L L (Station ) (Station n) (8) (.) C:. N7: 8. 9. 8 /8 [(P), (R) port] [() port] One-touch fitting [() port] pplicable tubing O.D.: ø., ø/8" ø, ø/" ø, ø/" 0.7 (7.) (). (Pitch) P = 0. The dashed lines indicate the DIN rail mounting [-D]. L-type plug (L) M-type plug (M) pprox. 00.9 [7.] 9.9 pprox. 00.7 [.9] 70. [77.] 9. [.] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Dimensions L n L L L L L 8. 7. 0. 8. 7 98 87.. 7. 0. 00 7 8. 8. 9 7. 7. 9 0 8 8 8 7. 0. 9. 9 8 7. 7. 0 0 0. 0 7... 7. 8 7. Formula: L = 0.n + 9. L = 0.n +. n: Stations (Max. 0 stations) 7 8 9 0 8. 98 0. 0.. 8 0. 7 7 87. 00 00. 7. 0. 8. 9 9. 80 90. 0.. 8. 9. 0... 7. 8. 9. 0... 7 77. 88 98. 09 9. 89

R P D side U side L L () (Rail mounting hole pitch:.) (Pitch) 8 P = (DIN rail clamp thread) (DIN rail) 7.8. PE port (X: External pilot port) <External pilot only> (8) / [(P), (R) port]. /8 /8 [() port]. pprox. 00 7.8 [.8] pplicable cable O.D. ø. to ø7 Max. 0 90. 8.9 7. Pg7 8 [8.] 88. 8. P R 00/00/00 Dimensions: 00 V- Stations Port size C Grommet (G) pprox. 00 7. 0 (.). x ø. (For mounting) L L L (.) (). 0 8. (.9).. () (Station ) (Station n) 0. One-touch fitting [() port] pplicable tubing O.D.: ø, ø/" ø, ø/" ø8, ø/" () (7.). 0. (Pitch) P = pprox. 00 9.[7.] 7. [7.] 7. (Pitch) P = L-type plug (L) M-type plug (M) DIN terminal (Y) The dashed lines indicate the DIN rail mounting [-D]. 89. Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Dimensions L n L L L L L 8. 7 7 98 87. 8 8 80. 8 9. 7. 00 8 90 8 7. 0 Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C 7 7. 0. 8 8. 7 8 9 8 9 98 87. 7 0 0. 00 80. 70. 9 0 8.9 Unless otherwise indicated, dimensions are the same as Grommet (G). Formula: L = n + 0 L = n + 0 n: Stations (Max. 0 stations) 7 8 9 0 0. 8. 98 0. 8 0. 7 0 7 87. 00. 7. 0. 8 0 7 9 08 0. 9 7.. 0 8.. 8 0 8 98 0 8 7. 8 0

R P (.) () Base Mounted 00/00/00 Dimensions: 00 V- Stations Port size C Grommet (G) pprox. 00 D side L L (Rail mounting hole pitch:.) (Pitch) P = 0 U side () (DIN rail clamp thread) (DIN rail). 9. PE port (X: External pilot port) <External pilot only> / [(R) port] 79.8 7. 9. () x ø. (For mounting) L 9 L L P R (8) /8 [(P) port] 9.. 8. (.). () (Station ) (Station n). One-touch fitting [() port] pplicable tubing O.D.: ø, ø/" ø8, ø/" ø0, ø/8" () (7.) 9. (Pitch) P = 0 / / [() port]. 9. (Pitch) P = 0 The dashed lines indicate the DIN rail mounting [-D]. L-type plug (L) M-type plug (M) DIN terminal (Y) pprox. 00. [7.] pprox. 00 7.8 [8.8] pplicable cable O.D. ø. to ø7 Max. 0 9.8 8. 7 Pg7 89. [9.8] 79.8 [8] 7.8 97. 7. 98. Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Dimensions L n L L L L L 98 87. 8. 8 8. 8 8 7. 0 88 0. 0 7. 08 8. 7 0 8 Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C 7 98 87. 8 8. 8 8. 8 9 8 7. 0 88 0 0. 0 7. 08 8. 7 0 8.9 Unless otherwise indicated, dimensions are the same as Grommet (G). Formula: L = 0n + 8 L = 0n + n: Stations (Max. 0 stations) 7 8 9 0 8 0. 8. 98 8 0.. 7. 0 7 87.. 7. 0 8 0 8 0 8. 7. 0 8. 7. 8 88 08 8 8 8 88 08 98 87. 8 8

00/00/00 Manifold Options Blanking plate assembly V00-0- (for 00) V00-0- (for 00) V00-0- (for 00) It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. Blanking plug KP- KP-0 KP-0 KP-08 KP-0 L ød Dimensions pplicable Model fitting size ød. 8 0 KP- KP-0 KP-0 KP-08 KP-0 (mm) L D 8 0.. 9 8 0 DIN rail XT00-DR- L 7. s for, enter the number from the DIN rail dimensions table. For L dimension, refer to the dimensions of each kit. () () Each manifold can be mounted on a DIN rail. Insert D at the end of the manifold part number. The DIN rail is approximately 0 mm longer than the length of manifold. L Dimension L =.n + 0. No. 7 8 9 0 7 8 9 0 L dimension. 8 0. 7 8. 98 0.. 8 0. 7 8. 98 0.. 8 0. No. 7 8 9 0 7 8 9 0 L dimension 7 8. 98 0.. 8 0. 7 8. 98 0.. 8 0. 7 8. 98 0. Silencer (for manifold EXH port) Silencer is installed in the manifold EXH port. ø N0-0 N0-0 ø. Dimensions Model Silencer part no. 00 N0-0 00 N0-0 00 N0-0 Port plug V00-CP (for 00) This is used when changing piping location. (Side or Top) 8

Base Mounted Semi-standard Specifications [Option] External Pilot Specification The external pilot specification is used when the operating pressure is below the minimum operating pressure 0. to 0. MPa or when valve is used for a vacuum application. Order a valve by adding the external pilot specification [R] to the part number. Valve Part No. R Entry is the same as standard products. Manifold Part No. V C Entry is the same as standard products. Inch Size One-touch Fittings and Optional Threads Inch size One-touch fittings and NPT, NPTF and G thread are available. Manifold Part No. V N7 T C Entry is the same as standard products. Entry is the same as standard products. Note) The pilot exhaust IP valves is common with main valve exhaust. (The standard valve has an individual exhaust for the pilot valve.) External pilot port Optional Threads Other than Rc Rc specifications are standard for all ports, however, NPT, NPTF and G are available for overseas markets. dd the appropriate symbol following the port size in the standard part number. Valve Part No. T Entry is the same as standard products. IP Enclosure (Based on IEC09) DIN terminal is available with IP enclosure. Cylinder port Symbol N N N7 N9 N NM Note ) M 0 0 pplicable tubing O.D. ø/8" ø/" ø/" ø/" ø/8" Mixed M thread /8 thread / thread Cylinder port 00 00 00 Note ) Except 00, mixing One-touch fittings and thread types is impossible. Note ) Metric size One-touch fittings (C) are also available. Valve Part No. (pplicable to the 00/00 rubber seal with the exception of the external pilot type) Y W R Pressure Specifications External pilot pressure range Note ) Metal seal Rubber seal (00: poppet) Operating pressure range Note ) 00 Note ) 00/00 0. to 0.7 MPa 0. to 0.7 MPa 0. to 0.7 MPa 00 kpa to 0.7 MPa Note ) In case of the high pressure type, upper limit of max. operating pressure and external pilot pressure range is MPa. Note ) When using the 00 series for a vacuum application, vacuum air through its (P) port. When supplying vacuum-release air, supply it through its (R) port. But do not supply vacuum-release air exceeding 0% for the external pilot pressure. In addition, when the 00 is to be used at an operating pressure greater than 0. MPa, please assure that the operating pressure is set to equal to or less than the external pilot pressure. Thread type (Cylinder port and (P), (R) ports) Rc N NPT T NPTF F G Thread type (Cylinder port and (P), (R) ports of sub-plate) Rc N NPT T NPTF F G 8

Base Mounted Replacement Parts One-touch Fitting ssembly (for Cylinder port) Fitting size Model 00 00 00 C C C C8 C0 VV000-0-C VV000-0-C VV000--C Note) Purchasing order is available in units of 0 pieces. VV000-0-C VV000--C VV000--C8 VV000--C VV000--C8 VV000--C0 M (00 only) VV000-0-M Without lead wire: SY00-0- (with and sockets only) <Gasket and screw assembly> Model Lead wire length 00 mm 0 0 0 0 00 mm 000 mm 00 mm 000 mm 00 mm 000 mm 000 mm How to Order Include the assembly part number together with the part number for the plug s solenoid valve without. Example) In case of 000 mm of lead wire DC -LO-M SY00-0--0 C -LO-M SY00-0--0 Part no. 00 00-GS- 00 00-GS- 00 00-GS- Note) bove part number consists of 0 units. Each unit has one gasket and two screws. Purchasing order is available in units of 0 pieces. <Sub-plate> <Plug assembly> DC: SY00-0-- 00 VC: SY00-0-- 00 VC: SY00-0-- Other C voltages: SY00-0-- Sub-plate part no. Model For internal pilot For external pilot 00 00-S-0 (-) 00-S-0 -R (-) 0 0 00 00-S- 0 (-) 00-S- 0 -R (-) 0 0 00 00-S- 0 (-) 00-S- 0 -R (-) Thread type 8 <Pilot valve assembly> Note) Semi-standard M V Function Symbol Specifications DC C Standard (0. W) B Note) High speed response type (pplicable to 00/00) K Note) High pressure type (pplicable to Metal seal type, Poppet seal type) None (pplicable to 00/00) Yes (pplicable to 00) V G <DIN terminal type (pplicable to the 00/00)> Function Symbol Specifications DC C Standard (0. W) B Note) High speed response type K Note) High pressure type (Metal seal type only) Note) Semi-standard Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC (0/0 Hz) 0 VC (0/0 Hz) VDC VDC Symbol Y YO YZ YS Note) YOS Note) Symbol DC C G LU LOU MU LZ LOZ MZ Valve model -L -M Y Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC (0/0 Hz) 0 VC (0/0 Hz) VDC VDC Grommet (DC specification) L-type plug with lead wire L-type plug without M-type plug with lead wire (pplicable to the 00) MOU MOZ M-type plug without Note) The electrical entry (L, M) for the 00 pilot valve is different from that of the main valve model number. Pilot valve model VM-M VM-L X0 Non-locking push type Locking slotted type Light/surge voltage None Yes Light/surge voltage Caution When replacing only the pilot valve assembly, use caution because it is not possible to convert to a V (DIN terminal) from a V (Grommet, L-type, M-type), or vice versa. B DIN terminal DIN terminal without DIN terminal with light/surge voltage DIN terminal with surge voltage (DC specification) DIN terminal with surge voltage, without (DC specification) None Yes Yes (Without light) Note) For C voltage valves there is no S option. It is already built-in to the rectifier circuit.