ProCod. User Manual. Programming software for TWK - Encoders Series CRF and DAF CRF 11069 DE 08 / 10



Similar documents
BIODEX ADDENDUM BIODEX EMG/ANALOG SIGNAL ACCESS CONFIGURATION UTILITY SOFTWARE FOR SYSTEM 3 REVISION 2 AND SYSTEM 4 DYNAMOMETERS

Installing PowerLink on Windows 7 64-bit

STIM202 Evaluation Kit

PM1122 INT DIGITAL INTERFACE REMOTE

2011, The McGraw-Hill Companies, Inc. Chapter 3

Installing the Gerber P2C Plotter USB Driver

DUKANE Intelligent Assembly Solutions

Driver Pant 8 and antenna switcher Ant 8. User manual

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Modbus RTU (RS-485) TCP/IP (Ethernet)

Transmitter Interface Program

PHD User Manual. Table of Contents

User Manual. AS-Interface Programmer

RS - SPM. Serial parallel translator module

Sartorius YAD01IS Win

S7 for Windows S7-300/400

GE Sensing. SiCalPro. Monitor and control software. User manual - K0452

PLC training panel (Twido version)

Application Note CTAN #374

PROGRAMMABLE LOGIC CONTROLLERS Unit code: A/601/1625 QCF level: 4 Credit value: 15 TUTORIAL OUTCOME 2 Part 1

Modbus Communications for PanelView Terminals

NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT.

Guide to Installing BBL Crystal MIND on Windows 7

USB PC Adapter V4 Configuration

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

Digital Photo Bank / Portable HDD Pan Ocean E350 User Manual

Orbit PCI Mk 2 Network Card. User Manual. Part No Issue 4

User Manual Software for DSL Digital Speed Switch

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

Installing an Omnicast System Omnicast version 3.5

Schneider OS-Loader usage via Ethernet or USB.

LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION

BuTeL Software - Scanner Over Ip - RemoteServer software July

Antenna Rotator System

PNOZmulti Configurator V8.1.1

Vicon Flash Upgrade Software

HP Point of Sale (POS) Peripherals Configuration Guide ap5000 VFD Windows (non-opos)

Device configurator DRC200

WHQL Certification Approval...2 User Interface...3 SUNIX s COMLab..4

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

GEIGER COUNTER "Gamma Check Pro"

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

The Answer to the 14 Most Frequently Asked Modbus Questions

Handheld LPC Utility Software for Windows. Operation Manual

RS485 Adapters. User Manual October 26, 2008 V1.02 Copyright Light O Rama, Inc. 2006, 2007, 2008 SC485 USB485B USB485 USB485-ISO

How to setup a serial Bluetooth adapter Master Guide

CashFlow Programming Module CPM

Vicon Flash Upgrade Software

isppac-powr1220at8 I 2 C Hardware Verification Utility User s Guide

PTPhoneManager II. User guide

SOFTWARE EasyComm (Code ) USER S MANUAL (Code M /00 - A) CIRCUTOR, S.A. All rights reserved

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

Korosi Monitoring System (KMS) Software Manual

USB Driver. Installation Manual

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

Parallels Transporter Agent

UDG1000 Hach PCX2200 Serial Port Input Driver configuration

SAPIP GUI INSTALLATION. Table of Contents

Addendum Advanced POS Printer Drivers

ScanWin Installation and Windows 7-64 bit operating system

SA-9600 Surface Area Software Manual

COM Port Stress Test

ENTBUS PLUS SOFTWARE FOR ENERGY MONITORING AND RECORDING INSTALLATION AND OPERATING MANUAL

EVAL-UFDC-1/UFDC-1M-16

Bluetooth HC-06 with serial port module Easy guide

Ash Capture Control User Guide

DIRECT INTERNET DATA. User s Guide

BIODEX. ATOMLAB 500/WIPE TEST COUNTER DATA MANAGER SOFTWARE Version 1.10 (and higher). OPERATION MANUAL

Guest PC. for Mac OS X. User Guide. Version 1.6. Copyright Lismore Software Systems, Ltd. All rights reserved.

File Management Utility. T u t o r i a l

Software User Guide UG-461

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

APPLICATION. Using the PB-100 to Make Calls and Announcements From a Database. Using the PB-100 for All-Call Dialing

1 Application Description Objective Goals... 3

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

Configuring the Siemens TC35 modems for use with the MI2292

Using Xbee in Serial Communication

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

AC500. Software Description. Scalable PLC for Individual Automation. Installation of the AC500 Control Builder PS501

RAID installation guide for Silicon Image SiI3114

WindO/I-NV2 Utility Pass-Through Tool

Application/Connection Examples

Bluetooth to Serial Adapter

1 Minimum system requirements

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Introduction to LogixPro - Lab

WinLIN Setup and Operation:

Current Cost Data Cable User Guide. Installing and configuring the data cable

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

User s Manual for Fingerprint Door Control Software

Connecting instruments serially to your computer

TDP-136 TRANSCEIVER DATA PROGRAMMER

Select Correct USB Driver

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version ( )

LTM-1338B. Plus Communications Manual

VSCOM USB PRO Series Industrial I/O Adapters

SOFTWARE INSTALLATION INSTRUCTIONS

Transcription:

Programming software for TWK - Encoders Series CRF and DAF CRF 11069 DE 08 / 10 User Manual ProCod TWK-ELEKTRONIK GmbH D-40041 Düsseldorf PB. 10 50 63 T. 02 11/96117-0 F. 02 11/96117-99 e-mail: info@twk.de http://www.twk.de - 1 -

COPYRIGHT: The user manual CRF 11069 is owned by TWK-ELEKTRONIK GmbH and is protected by copyright laws and international treaty provisions. 2002 by TWK-ELEKTRONIK GmbH POB 10 50 63 40041 Düsseldorf Germany Tel. +49/211/96117-0 Fax +49/211/96117-99 e-mail: info@twk.de internet: www.twk.de - 2 -

Content 1. Introduction... 4 2. Requirements... 4 2.1 Hardware requirements... 4 2.2 Software requirements... 4 3. Install / Remove... 4 4. Connecting the encoder... 5 5. Basics to communication... 5 6. Operating ProCod... 5 6.1 Starting the program... 5 6.2 Changing the language... 5 6.3 Changing the serial interface... 6 6.4 Changing the encoder type... 6 6.5 Establishing connection... 6 6.6 Programming the encoder... 7 6.7 Programming the encoder DAF... 7 6.8 Read position, Set reference values... 7 Appendix... 8 Parameter list... 8 Parameter terms... 8 Relevant datasheets... 8-3 -

1. Introduction The software ProCod serves to program the TWK-Encoders CRF (SSI, ASA, parallel output interface) and DAF (VDC or ma analogue output signal). In addition to the programming of the parameters it is possible to read the actual position continuously and set the reference values. Each set of parameters can be stored in an individual file or printed out with additionel project data. When setting you can switch between the languages German, English and French. 2. Requirements 2.1 Hardware requirements - Standard PC with at least 486-compatible processor and one free serial port COM1 or COM2. - Converter module PF-K9UM0x from TWK, responsible for converting the RS232 interface of the PC into the encoders RS485 interface and for send/receive-switching, inclusive of connecting cable and Null-modem-cable. - 24V power supply for the encoder and the converter module. 2.2 Software requirements - Installed operating system Win9x, WinNt 4.0 (SP4), Windows 2000 or Windows XP. - The software is not working under Win32s, in a Windows emulation of OS/2 or other operating systems or in virtual machines. 3. Install / Remove Under Windows NT, 2000 and XP you must have administrator privileges to install ProCod. To Install insert the ProCod-CD in your CDROM-Drive. The setup program will start automatically. If setup does not start, please execute the Setup.exe (from version 1.53 onwards: install.bat) file in the root directory of the ProCod-CD manually. During the installation of ProCod a special serial driver is installed with the ProCod user program. This driver expands the functionality of the serial interface of ProCod specific functions. Afterwards you can find the program under Start > Programs > TWK > ProCod. To Remove ProCod choose under Control panel > Software > Install/Remove the line ProCod and click on Add/ Delete. The Driver ProCod Driver Version x.x will be uninstalled automatically. (From Version 1.53 onwards the driver has to be uninstalled separately. Alternatively, the uninstall.bat can be started from the Installation CD). The specific interface driver is removed only after the restart from the system. - 4 -

4. Connecting the encoder Connect the encoder via the converter module, as shown in the following figure, with the PC and switch on power supply. Figure 1: Hardware configuration Note: The supply voltages for encoder and converter should not be separated (common signal ground). The interface used for connection (COM1 or COM2) has to be selected in the program. 5. Basics to communication The communication between PC and encoder is based on the following parameters: Baudrate: 4800 Parity: no Databits: 8 Stopbits: 2 They will be adjusted by ProCod and can not be changed by the user. Since for communication between converter module and encoder via RS422/485 only two wires are used, the communication direction has to be switched between sending and receiving to/from encoder in the converter module. For this switching the RTS-Signal of the RS232 interface of the PC is used. If there are hard disk accesses by the PC during communication with the encoder the synchronous switching of send/ receive direction will be disturbed and the connection to the encoder will break down. It can be re-established by the button Online immediately. Therefore the connection will be shift to offline bevor ProCod accesses the hard disk. 6. Operating ProCod 6.1 Starting the program After installation you can find the program under Start > Programs > TWK > ProCod. After the first start it appears with the default settings: German, interface COM1, encoder type parallel. 6.2 Changing the language You can choose between the languages German, English and French in the main menu under Settings > Language. After changing the language it is necessary to restart ProCod. - 5 -

6.3 Changing the serial interface In the main menu under Settings > Interface you can choose between COM1 and COM2. A restart after changing is not necessary. The adjustment is only possible in the offline mode. The actual interface is shown in the status bar. 6.4 Changing the encoder type ProCod is able to programme all programmable TWK encoders with the following types of interfaces: - parallel - SSI - ASA - analogue You can set the type under Settings > Encoder type. After changing the type the parameter list is rebuilt with the default values and shows the relevant parameters for this type only. The type selected is displayed above the parameter field. (See figure 2) 6.5 Establishing connection To programme or to read the parameters of the encoder, you have to establish the connection via the button Online or via the main menu under Operate > Online first. During connecting the encoder is set into the programming mode. After that the encoder type and additional hardware data, which are necessary to check the entered parameter values, are read. If the type of the connected and the adjusted encoder do not agree, a message will appear to ask you to decide whether to accept the online type or to stay offline. If you select Stay offline, the encoder type will not be changed and the establishing of the connection will become interrupted. After accepting the online type, the parameter list is rebuild with the default values and shows the relevant parameters for this type only.the type selected is displayed above the parameter field. (See figure 2) After the online-state is reached, the entered parameters will be checked depending on the hardware data of the encoder. In the online-state the buttons Read encoder, Program encoder and Read position are available. Figure 2: Parameter list - 6 -

6.6 Programming the encoder Depending on the type of encoder different parameters are progammable. A list of all parameters for every type is located in the appendix and in the connector arrangement description which comes with every encoder. The parameters can be entered offline and online. In the offline mode it is possible to print and save the parameter sets separately for every type of encoder. The validity of the values will be checked during editing. Offline a range check with the default limits is done. Online the entered values will be checked against the hardware data of the encoder. They can be adjusted automatically to the valid highest or lowest value. The fractional part of the resolution, the monfloptime of SSI and the baudrate of ASA can, depending on their hardware data, only accept certain values. In the online status non valid values will be recognized and automatically adapted. To change individual parameters you should read out the actual encoder values first. With the button Program encoder always all parameters are send to the encoder. Before sending the parameters to the encoder the validation check of all values is done again. 6.7 Programming the encoder DAF For the encoder DAF you can choose between three different possibilities of programming depending on the application. They differ in the parameters for resolution and reference values. In every of these cases a diagram illustrates the setted values. 1. Input in steps Here you can program the parameters for resolution as number of steps per turn, for the measuring range as number of turns and for the reference values as number of steps. The parameters will be sent to the encoder without any conversion. 2. Input in steps, reference values analogue Whenever you want to enter the reference values directy in form of Milliamps or Volts ( and not to convert them into steps) than use this method. The resolution is entered as number of steps like before, but the reference values can be entered as analogue values directly. The program will make the conversion into steps in the background. The relationship between analogue value and number of steps is shown in the datasheet 10295 on the CD. The correct setting of the encoder type (A,B or C) is compulsory, otherwise the conversion from analogue into steps will be wrong. 3. Input in turns If you want to programm the analogue measuring range in number of turns directly, e.g. to obtain 20mA after 17,5 turns of a spindel, take this method of programming. Instead of programming the resolution in number of steps you enter the working range (here:17,5 turns) in number of turns directly. The programm calculates the resolution per turn and suggests a measuring range in turns. If the desired working range is not a 2 n value, the next higher 2 n value is suggested for the measuring range. The difference between working range and measuring range is the overflow. The relation between working range and resolution is also explained in the datasheet 10295. Using this method the reference values are equally entered analogue. Please pay attention of the setting of the correct encoder type. 6.8 Read position, Set reference values With the button Read position you can switch the continuous reading of the actual position value on and off. For the SSI and parallel types the parity error and the encoder error are displayed as well. The number displayed on the top shows always the position value converted to decimal. The number on the buttom shows the original position value coming from the encoder in hexadecimal. Depending on the adjustment mode (Preset or Up-/Down) the buttons for setting the reference values or for the Up/ Down-mode are made available. Please note that in Up/Down mode, the value which is set by the Up/Down buttons is stored in the encoder after 6 seconds. - 7 -

Appendix Parameter list Parallel SSI ASA DAF Default value Range* Resolution [steps per turn] 4096 0.0002...4096 Measuring range [turns] 4096 1...4096 Output code gray Gray, binary, BCD, Graytree, binary-tree Code sense cw cw, ccw Parity bit - even even, odd Logic polarity - - - positive positive, negative Adjustment mode Preset Preset, Up/Down Reference value 1 [steps] 0 0...total measuring steps -1 Reference value 2 [steps] 0 0...total measuring steps -1 Offset value [steps] - 0 ± (total measuring steps -1) bzw. -32768...32767 Register length [bit] - - 32 13, 16, 25, 32 Monoflop time [µs] - 20 1...682 Baudrate [Baud] - - 62500 1465...3000000 Identification number 0 0...65535 *The range may differ from the shown values depending on the encoder. Parameter terms Resolution - Specifies the number of steps per turn (revolution). For the output codes Gray, binary and BCD values behind the decimal point are possible. If the entered fractional part is not convertable into a binary value, it is automatically adjusted. Measuring range - Total number of turns before switchng again to zero. Total measuring range- This value results from the parameters resolution and measuring range and is for reference only. It is not editable. Output code - Output code of the position value. Code sense - The code sense specifies the direction of revolution in which the output code increases. cw - increases values when turning clockwise ccw- increase values when turning counter clockwise (View on the shaft end) Parity bit - Defines whether the encoder should output the even or odd parity. Logic polarity - Only valid for parallel interface. Defines the assignement of logical value and voltage level. positive Logic negative Logic H-Level = log. 1 H-Level = log. 0 L-Level = log. 0 L-Level = log. 1 Adjustment mode - Defines the function of the multi-functional inputs. Preset: The reference values are setable via the multi-functional inputs or by ProCod. Up/Down: The output value is setable step by step via the multi-functional inputs or via ProCod. Reference value - The reference value is the value which is output after the function set reference value (via the multi-funcional pins or via ProCod). Offset value - Shifts the output value by a preset amount. Register length - Length (number of data bits) of SSI-protocoll. Monoflop time - Serves for synchronisation of data transmission of the SSI-interface. Baudrate - Transmission rate in Baud (Bit/s) of ASA-Interface. Id-Nummer - The identification number can be allocated to each specific encoder. Relevant datasheets Encoder CRF - CRF 10266 Encoder DAF - DAF 10286 and DAF 10295 Converter PF-K9UM00 - PF 10713-8 -