PLC training panel (Twido version)

Size: px
Start display at page:

Download "PLC training panel (Twido version)"

Transcription

1 PLC training panel (Twido version) User manual Name School of Trades

2 Produced by: GJR October 2012 Colour leaves: 9 BW leaves: 2 Cover colour: White Cover image: G.J.Rogerson Acknowledgments: Much of the material in this resource and the accompanying online content has been made possible by the generosity of Schneider Electric Group, enabling us to use their diagrams and text.

3 Table of Contents Introduction... 2 Safety... 2 Specifications... 3 The Panel - Main components... 4 The Panel - Inputs & outputs... 5 I/O allocation... 6 Communicating with the PLC Serial Connection PC USB to Twido Port PC Ethernet to Twido via Twidoport adaptor PC to Twido using a LAN or network router... 8 Appendices... 9 Appendix A: How to configure a PC with a fixed IP address Appendix B: Configuring the USB serial cable Appendix C: Wiring and connection diagram Appendix D: Module wiring information Wintec 2012

4 Introduction This user manual has been developed to give PLC course attendees most of the information required to safely use the Twido-equipped PLC training panel, as shown right. As much information as practicable, has been included to enable independent learning of programming and interfacing. This panel uses a Twido PLC and requires the use of Twidosuite programming software. The full Twidosuite programming guide is available at Schneider s website: Safety Important! Wiring diagrams are included in this manual to ensure the correct connection of any external apparatus. Simple protection of the PLC and Touchscreen are offered in the form of 20mm fuses but care should always be taken to ensure that damage is not caused to modules by the incorrect use or connection of I/O equipment. Although the Touchscreen, PLC and I/O operate at 24Vdc, 230Vac is still present at the PSU module and the panel is highly conductive (although it is well earthed though the mains connection). Be aware of this, especially when water is involved in the lab or practical. The automatic control of moving mechanical parts is made possible by some apparatus when connected to a running PLC. This could cause injury if you do not take care when powering up your application. Lastly, you may have noticed that the PLC is heavy and has a movable leg for standing upright. Watch your fingers when manoeuvring and mind your back when lifting. PLC module user manual 2

5 Specifications Phaseo power supply Input voltage Vac Output voltage 24Vdc Output power (nominal) 30W Output current (nominal) 1.2A Twido TWDLMDA20DRT modular controller (24v) 24V digital inputs 12 24V digital outputs Maximum output current 8 (2 transistor, 6 relay) 0.3A per transistor output 2A per relay output Interfaces Port-1 8-pin DIN serial Ethernet RJ-45 via additional Twidoport connected to port-1 Program memory 3000 steps capacity Additional features Real-time clock fitted Analogue I/O (via additional TM2aMM6HT module) Inputs Outputs 4 (0-10V or 4-20mA) 2 (0-10V or 4-20mA) Magelis HMI STU655 touchscreen 320 x 240 pixel, 65k colour 1 serial 485 (RJ-45), 2 USB, 1 Ethernet (RJ-45) 3 Wintec 2012

6 The Panel - Main components Magelis Ethernet port Magelis HMI Twido Ethernet port 24Vdc PSU PLC IEC mains inlet PLC module user manual 4

7 The Panel - Inputs & outputs LAMP1 LAMP2 0-10V output meter LAMP4 LAMP3 0-10V input socket SW1 SW2 SW3 SW4 0-10V input control 14-pin Centronics socket for additional analogue I/O 24-pin Centronics socket for additional digital I/O 5 Wintec 2012

8 14-pin socket 24-pin Centronics socket Parallel with 24-pin I/O allocation Hardware PLC D I/O PLC A I/O PLC address LAMP1 Output 0 %Q0.0 LAMP2 Output 1 %Q0.1 LAMP3 Output 2 %Q0.2 LAMP4 Output 3 %Q0.3 Output 4 Output 5 %Q0.4 %Q0.5 Output 6 Output 7 Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 %Q0.6 %Q0.7 %I0.0 %I0.1 %I0.2 %I0.3 %I0.4 %I0.5 %I0.6 %I0.7 SW1 Input 8 %I0.8 SW2 Input 9 %I0.9 SW3 Input 10 %I0.10 SW4 Input 11 %I V input control Input 0 %IW V input socket Input 1 %IW V panel meter Output 0 %QW mA or 0-10V in Input 2 %IW mA or 0-10V in Input 3 %IW mA or 0-10V out Output 1 %QW1.1 Why do the panel switches start at input 8? Several additional input functions are available within inputs 0-7, including high speed counters etc. These would therefore be wasted if used for discrete panel switches only. PLC module user manual 6

9 Communicating with the PLC There are several ways of interfacing with the Twido PLC for configuring the processor and uploading or downloading the program. 1. Serial Connection PC USB to Twido Port 1 This requires a special two-piece cable. (TSXCUSB485 and TSXCRJMD25) Once Twidosuite software has been installed, your computer should be able to find this cable and assign a COMS port to it. If you encounter any trouble, see the additional info in appendix B or see your tutor. 2. PC Ethernet to Twido via Twidoport adaptor An RJ-45 cross-over patch lead can connect directly from the Ethernet port of your PC to the Twidoport. Your computer must be set-up with a fixed IP address that is in the correct network address range. See Appendix B to configure your PC. 7 Wintec 2012

10 3. PC to Twido using a LAN or network router Once set up correctly, this method allows all devices connected to the same router (or LAN) to communicate with each other. The Magelis HMI s can also be programmed and linked this way. This method also requires that each device and computer has a unique IP address within a specified range. The PLC panels are already configured with fixed IP addresses as shown below. PLC Magelis PLC Magelis PLC Magelis PLC Magelis PLC Magelis PLC Magelis and so on. These address ranges are used only because they are easy to remember. Your tutor may assign an IP address for you to use as YOUR fixed computer IP however, you can make up your own, as long as it does not clash with another device or user. My fixed computer IP address:... Please do not alter the PLC or Magelis IP addresses, unles you have the approval of your tutor, PLC module user manual 8

11 Appendices 9 Wintec 2012

12 Appendix A: How to configure a PC with a fixed IP address 1. Go to Control Panel 2. Click on Network and Internet PLC module user manual 10

13 3. Go to View network status and tasks. 4. Click on Local area connection. Note: you will need to have a network cable inserted to either a device or router. 11 Wintec 2012

14 5. Click Properties on the window that appears. 6. Select TCP/IP version 4 protocol and click on Properties. PLC module user manual 12

15 7. Click the button for Use the following IP address. 8. Type in the appropriate IP address. Check that subnet mask is then click OK. Subnet mask should also work as well. Leave Gateway blank. 13 Wintec 2012

16 Appendix B: Configuring the USB serial cable The following has been extracted from a document by John Caldwell of Schneider Electric, NZ. Step 1. Install TwidoSuite software then exit TwidoSuite. 2. Connect the interface cable to your PC and Twido. TSX CUSB 485 cable, USB torj45 + TSXCRJMD25 cable, RJ45 to minidin rotary switch position 0, polarization OFF 3. Run Schneider Electric/Communication drivers/drivers manager. Select the MODBUS SERIAL Driver tab. PLC module user manual 14

17 4. Click Configuration and on the COM Port drop-down menu, select the com port that has the cable name and (ready) next to it. If (ready) does not appear, unplug the USB connector and plug it back in again. Close the Modbus Driver window and go to step 3 above. Check that the Baud rate is 19.2, 1 stop bit and Parity at None then click OK 15 Wintec 2012

18 5. If (ready) does not appear, uninstall your comms driver then unplug the USB cable and then plug the cable back in and it will reinstall the comms driver. The whole trick here is to get the word (ready) to appear to the right of the cable name as in STEP Start TwidoSuite and go to Monitor Mode and try to establish a connection with one of the existing connections (if there are any shown). PLC module user manual 16

19 If none of these work, click the Manage connection button at the bottom of the Twido screen. Click Add and set up Connection mode to Serial and IP address/number to the port number shown as (ready) in STEP 4. Click Apply and establish communication with the Twido. If this works you are done. If there is no com port corresponding to the com port of STEP 4, then exit TwidoSuite, unplug the USB cable. Wait a few seconds then plug the USB cable back in and restart TwidoSuite. 17 Wintec 2012

20 Appendix C: Wiring and connection diagram PLC module user manual 18

21 19 Wintec 2012

22 20

23 Appendix D: Module wiring information TWD LMDA20DRT modular PLC TM2AMM6HT analogue I/O module 21 Wintec 2012

24 22

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

Application Note: Connecting to a 2500 Series Processor using PLC Workshop Application Note: Connecting to a 2500 Series Processor using PLC Workshop This application note will describe a step by step process for the three ways to connect to a 2500-CXXX with PLC Workshop. The

More information

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly

More information

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

ETHERNET WEATHER STATION CONNECTIONS Application Note 33 ETHERNET WEATHER STATION CONNECTIONS Application Note 33 With WeatherLink and a Device Server INTRODUCTION It is possible to substitute an Ethernet connection for the direct USB or serial connection that

More information

Schneider OS-Loader usage via Ethernet or USB.

Schneider OS-Loader usage via Ethernet or USB. LHC Gas Systems 28 th February, 2007 Schneider OS-Loader usage via Ethernet or USB. Jacques ROCHEZ - IT/CO/FE Abstract This document is a guideline on how to configure correctly a PC for the use of the

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification: PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,

More information

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW) Page 1 of 20 Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW) Document ID: 50036 Contents Introduction Prerequisites Requirements Components Used Network Diagram The Role of Switched

More information

DUKANE Intelligent Assembly Solutions

DUKANE Intelligent Assembly Solutions PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc

More information

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012 Quick Note 32 Using Digi RealPort with a Digi TransPort Router UK Support September 2012 1 Contents 1 Introduction... 3 1.1 Outline... 3 1.2 Assumptions... 3 1.3 Version... 3 2 Configuration & scenario...

More information

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

E-Mon Communication Gateway Utility Instructions for BACnet/mstp E-Mon Communication Gateway Utility Instructions for BACnet/mstp The E-Mon Communication Gateway utility will allow you to configure the Device Instance (Node ID) and other parameters needed for your BACnet/mstp

More information

User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M)

User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) Document code: MN67038-2_ENG Revision 1.400 Page 1 of 25 User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) for

More information

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is

More information

Wireless LAN 802.11g USB Adapter

Wireless LAN 802.11g USB Adapter Wireless LAN 802.11g USB Adapter User s Guide Version 1.0 User s Guide 0 Copyright statement No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

GV-Data Capture V3 Series User's Manual

GV-Data Capture V3 Series User's Manual GV-Data Capture V3 Series User's Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2006 GeoVision, Inc. All rights

More information

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6

More information

EZ-View Network Communications Guide www.cszindustrial.com

EZ-View Network Communications Guide www.cszindustrial.com Network Communications Guide EzView Network Communications Guide RevB July 2013 (V2.2) Supersedes: RevA (May 2011) Cincinnati Sub-Zero Products, LLC 513-772-8810 12011 Mosteller Road Cincinnati, Ohio 45241

More information

Current Cost Data Cable User Guide. Installing and configuring the data cable

Current Cost Data Cable User Guide. Installing and configuring the data cable Current Cost Data Cable User Guide Installing and configuring the data cable Contents About the Data Cable... 3 Data Cable Installation Steps... 3 Post Installation Checks... 3 So the driver is installed,

More information

User Manual Revision 2.003 English

User Manual Revision 2.003 English Document code: MN67120_ENG Revision 2.003 Page 1 of 15 User Manual Revision 2.003 English RS232 / RS485 / Ethernet - Converter (Order Code: HD67120) for Website information: www.adfweb.com?product=hd67120

More information

Ultra Thin Client TC-401 TC-402. Users s Guide

Ultra Thin Client TC-401 TC-402. Users s Guide Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE

More information

Configuring the Switch with the CLI Setup Program

Configuring the Switch with the CLI Setup Program APPENDIXC Configuring the Switch with the CLI Setup Program This appendix provides a command-line interface (CLI) setup procedure for a standalone switch. To set up the switch by using Express Setup, see

More information

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 1 PURPOSE:... 1 2 CPM-4/CPM-2 COMPATIBILITY... 2 2.1 NETWORK CABLES... 2 2.2 FACTORY DEFAULT SETTINGS... 2 2.3 CHANGING THE RS-232 SERIAL PORT BAUD

More information

Enabling Internet Connection Sharing on Windows 2000 15. Enabling ICS On Windows XP As The Host 4 Enabling ICS On Windows XP As The Client 11

Enabling Internet Connection Sharing on Windows 2000 15. Enabling ICS On Windows XP As The Host 4 Enabling ICS On Windows XP As The Client 11 Sharing an Internet Connection with SatDirect Plus Table of Contents Contents Section 1: Section 2: Section 3: Introduction... 1 Physical Setup......2 Enabling Internet Connection Sharing on Windows XP

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700

APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700 Tel: +90-216 466 84 60 Fax: +90-216 364 65 65 datakom@datakom.com.tr http://www.datakom.com.tr APPLICATION NOTE Ethernet Configuration Guide for D-500 D-700 PRODUCTS AFFECTED: D-500 / D-700 WRITTEN BY:

More information

Ethernet Interface Manual Thermal / Label Printer. Rev. 1.01 Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

Ethernet Interface Manual Thermal / Label Printer. Rev. 1.01 Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2 Ethernet Interface Manual Thermal / Label Printer Rev. 1.01 Metapace T-1 Metapace T-2 Metapace L-1 Metapace L-2 Table of contents 1. Interface setting Guiding...3 2. Manual Information...4 3. Interface

More information

Modbus RTU (RS-485) TCP/IP (Ethernet)

Modbus RTU (RS-485) TCP/IP (Ethernet) Eaton Innovative Technology PEM PC Software Installation and Operation Instruction Manual: IM01005006E Rev. 2 March 2007 Modbus RTU (RS-485) TCP/IP (Ethernet) Effective Date 3/2007 For more information

More information

DSL Installation Guide

DSL Installation Guide DSL Installation Guide Thank you for choosing Integra Telecom s DSL service! Introduction This guide will walk you through the DSL installation process and will help you configure a computer to access

More information

Self Help Guide IMPORTANT! F5D7330 - Setting Up An Ad Hoc Connection. Please read the following carefully;

Self Help Guide IMPORTANT! F5D7330 - Setting Up An Ad Hoc Connection. Please read the following carefully; IMPORTANT! This Guide refers to the following Products: F5D7330 - Setting Up An Ad Hoc Connection Please read the following carefully; Synopsis: This guide is designed to assist in you in forming an ad

More information

1-Port Wireless USB 2.0 Print Server Model # APSUSB201W. Quick Installation Guide. Ver. 2A

1-Port Wireless USB 2.0 Print Server Model # APSUSB201W. Quick Installation Guide. Ver. 2A 1-Port Wireless USB 2.0 Print Server Model # APSUSB201W Quick Installation Guide Ver. 2A Section 1 Step 1Connect one end of the Ethernet cable to the RJ-45 port of the Print Server and attach the other

More information

1 Serial RS232 to Ethernet Adapter Installation Guide

1 Serial RS232 to Ethernet Adapter Installation Guide Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).

More information

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page

More information

E-Blocks Easy Internet Bundle

E-Blocks Easy Internet Bundle Page 1 Cover Page Page 2 Flowcode Installing Flowcode Instruction for installing Flowcode can be found inside the installation booklet located inside the Flowcode DVD case. Before starting with the course

More information

Computer Networks I Laboratory Exercise 1

Computer Networks I Laboratory Exercise 1 Computer Networks I Laboratory Exercise 1 The lab is divided into two parts where the first part is a basic PC network TCP/IP configuration and connection to the Internet. The second part is building a

More information

ADSL Router Quick Installation Guide Revised, edited and illustrated by Neo

ADSL Router Quick Installation Guide Revised, edited and illustrated by Neo ADSL Router Quick Installation Guide Revised, edited and illustrated by Neo A typical set up for a router PCs can be connected to the router via USB or Ethernet. If you wish to use a telephone with the

More information

TE100-P21/TEW-P21G Windows 7 Installation Instruction

TE100-P21/TEW-P21G Windows 7 Installation Instruction Hardware Installation TE100-P21/TEW-P21G Windows 7 Installation Instruction 1. Go to http://www.trendnet.com/downloads/ to download the Windows 7 Utility. Save the file to your desktop. 2. Right click

More information

Communications Instructions for DOOSAN, FANUC Controls

Communications Instructions for DOOSAN, FANUC Controls Communications Instructions for DOOSAN, FANUC Controls Ethernet & RS-232 for; 18i, 21i, 0ib and c 30i Series & 0id - 1 - Table of Contents Section 1... 3 Ethernet Set-up for the PC... 3 Description...

More information

Voice Over Internet Protocol (VoIP) Configuration

Voice Over Internet Protocol (VoIP) Configuration (VoIP) Configuration ENGINEERING REPORT No: 02-003 Introduction This report describes interfacing the IPCS VoIP Gateway Model EGW-902 to an ESTeem Model 192E Wireless Ethernet radio modem in a demonstration

More information

Application & Quick-Start Guide

Application & Quick-Start Guide Model: CRMWIC Web Intelligent Controller 1 This document will illustrate various ways to connect and use a CRM-WIC as well as programming examples. When connecting CRM-WIC, the installer has several interface

More information

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Ethernet. Customer Provided Equipment Configuring the Ethernet port. Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.

More information

User Manual. Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP)

User Manual. Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP) User Manual Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP) UMPCEA Rev 1.0, 05/2007 COPYRIGHT NOTICE This manual is a publication of Brainchild Electronics Co... Ltd.

More information

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version

More information

EDGE FX Network configuration

EDGE FX Network configuration Page 1 of 16 TITLE: Category: EDGE FX Network configuration GERBER EDGE Document Number: 4280 Supplied by: Gerber Service Last Modified: April 14, 2011 Summary: In order to connect an EDGE FX to your PC

More information

ON HOLD ANNOUNCER. Once you receive your audio announcer, check the packaging to ensure that all of the following items are enclosed:

ON HOLD ANNOUNCER. Once you receive your audio announcer, check the packaging to ensure that all of the following items are enclosed: ON HOLD ANNOUNCER The is a high quality digital on-hold announcer. It is designed to be attached to a 100BASE-T Ethernet network to receive audio production updates via the Internet. These instructions

More information

WUA-0605 300Mbps Wireless USB Network Adapter

WUA-0605 300Mbps Wireless USB Network Adapter WUA-0605 300Mbps Wireless USB Network Adapter User Manual V1.0 Certification FCC CE FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant

More information

Portable BACnet /IP to MS/TP Router

Portable BACnet /IP to MS/TP Router Portable BACnet /IP to MS/TP Router Installation Instructions TL-BRTRP-0 Part No. 24-10414-2, Rev. F Issued April 2016 Refer to the QuickLIT website for the most up-to-date version of this document. Applications

More information

1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3

1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3 Contents Moxa Technical Support Team support@moxa.com 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements... 4 4 Configuration...

More information

Installation and Operation Guide

Installation and Operation Guide www.aja.com Quick Start Guide Introduction This Quick Start Guide provides a basic overview of KUMO configuration. It is not meant as a substitute for the detailed information found in the KUMO Manual,

More information

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier Refer to the Lifestyle SA-2 & SA-3 Amplifier service manuals, part number 271720 for schematics, PCB layouts and parts lists. Preventative Repair Measures

More information

1 INTRODUCTION. This document describes the procedure to upgrade LTMR.

1 INTRODUCTION. This document describes the procedure to upgrade LTMR. 1 INTRODUCTION This document describes the procedure to upgrade LTMR. Limitation: this package and procedure describe only the upgrade of the LTMR firmware for all network versions (Modbus, Profibus, DeviceNet,

More information

Connecting your Omega/BetaPAT PLUS to a PC via a USB

Connecting your Omega/BetaPAT PLUS to a PC via a USB Connecting your Omega/BetaPAT PLUS to a PC via a USB Install software Windows XP and below Insert the disc into your computers disc drive and run through the setup wizard. Windows Vista & 7 1. Insert the

More information

Follow these steps to prepare the module and evaluation board for testing.

Follow these steps to prepare the module and evaluation board for testing. 2 Getting Started 2.1. Hardware Installation Procedure Follow these steps to prepare the module and evaluation board for testing. STEP1: Plug the EG-SR-7100A module into the sockets on the test board.

More information

2 Setting Up the Hardware for a Wired Ethernet Network... 13. 3 Setting Up the Software for an Ethernet Network... 21

2 Setting Up the Hardware for a Wired Ethernet Network... 13. 3 Setting Up the Software for an Ethernet Network... 21 Contents 1 Networking Basics............................................... 1 Selecting a network connection........................................ 2 Wired Ethernet network...........................................

More information

FINS Gateway For OMRON PLCs

FINS Gateway For OMRON PLCs 1 Purpose This Technical Note describes how to set up a remote collaboration. A remote collaboration consists in configuring, programming or monitoring a PLC from a remote location, without the need of

More information

This techno knowledge paper can help you if: You need to setup a WAN connection between a Patton Router and a NetGuardian.

This techno knowledge paper can help you if: You need to setup a WAN connection between a Patton Router and a NetGuardian. Problem: Patton / 240T WAN Setup Platform: NetGuardian 240T This TKP is a guide to setting up a PPP to T1 WAN connection between a Patton Model 2603 Router and a NetGuardian 240T. The example in this guide

More information

User Manual Revision 1.002 English

User Manual Revision 1.002 English Document code: MN67513_ENG Revision 1.002 Page 1 of 15 User Manual Revision 1.002 English Gateway / Adapter CAN to Ethernet (Order Code: HD67513 HD67513M) HD67513 for Website HD67513 information: www.adfweb.com?product=hd67513

More information

Troubleshooting 920i / iqube Email Issues

Troubleshooting 920i / iqube Email Issues TM UNITS PRINT Troubleshooting 920i / iqube Email Issues If you are having trouble connecting to your networked 920i, the problem might be caused by IP addressing or network firewall issues. First, see

More information

Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry. IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input

More information

WindO/I-NV2 Utility Pass-Through Tool

WindO/I-NV2 Utility Pass-Through Tool B-1159(3) WindO/I-NV2 Utility Pass-Through Tool Instruction Manual Introduction This instruction manual explains the operation and handling of the WindO/I-NV2 Utility Pass-Through Tool. Before using the

More information

PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications

PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications PC/POLL SYSTEMS supports native TCP/IP polling for the SPS2000 cash register. It is recommended users have the register updated

More information

Installation Manual Premier Elite ComIP

Installation Manual Premier Elite ComIP Installation Manual Premier Elite ComIP INS273-5 Overview Introduction The ComIP module allows the Premier & Premier Elite control panels to be connected to either a Local Area Network (LAN) or Wide Area

More information

SMART Board Software for Macintosh FAQ

SMART Board Software for Macintosh FAQ SMART Board Software for Macintosh FAQ NOTE: The following FAQs relate to the latest SMART Board Software for Macintosh release and apply only to Macintosh computers. SMART Board Software for Macintosh

More information

Internet for Everyone In-Room Instructions January 2011 Version 1.3

Internet for Everyone In-Room Instructions January 2011 Version 1.3 Internet for Everyone In-Room Instructions January 2011 Version 1.3 Everywhere Internet 2006 Page 1 of 17 Connecting your computer to the Everywhere Internet network in your room 1. You need a network

More information

How to use KEPServerEX OPC Server (Kepware) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)

How to use KEPServerEX OPC Server (Kepware) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021) Alex Chen, Senior Engineer, Moxa Technical Support Dept. In this Technical Note, we cover the following topics: 1. How to export

More information

Adding a Modbus TCP Device to the Network. Setting Up Your Network

Adding a Modbus TCP Device to the Network. Setting Up Your Network Page 1 of 17 Adding a Modbus TCP Device to the Network Overview This section extends the sample Unity Pro application, by describing how to: add an STB NIP 2212 Modbus TCP network interface module to your

More information

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade Installation Instructions SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade Catalog Numbers 1747-DU501 Topic Page System Requirements 3 Install ControlFLASH 3 Prior to Running ControlFLASH

More information

Connecting the DG-102S VoIP Gateway to your network

Connecting the DG-102S VoIP Gateway to your network Contents of Package: DG-102S VoIP Station Gateway Power adapter CD-ROM, including User s Manual Quick Install Guide Requirements: RS-232 Console Cable Two RJ-45 CAT-5 Straight-Through Cables For more information

More information

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers. How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers. OMEGALOG Help Page 2 Connecting Your Data Logger Page 2 Logger Set-up Page 3 Download Data Page 8 Export Data Page 11 Downloading

More information

Job Aid Pre-Installation Information S8500 Media Server

Job Aid Pre-Installation Information S8500 Media Server Required information Job Aid Pre-Installation Information S8500 Media Server This job aid provides the information, hardware requirements, and computer hardware and software specifications necessary for

More information

1 Application Description... 2 2 System Topology... 2 3 Hardware and Software Requirements... 3

1 Application Description... 2 2 System Topology... 2 3 Hardware and Software Requirements... 3 Contents Moxa Technical Support Team support@moxa.com 1 Application Description... 2 2 System Topology... 2 3 Hardware and Software Requirements... 3 3.1 Hardware Requirement... 3 3.2 Software Equipment...

More information

Your peace of mind. Twido Programmable controllers

Your peace of mind. Twido Programmable controllers Your peace of mind Twido Programmable controllers Need efficiency for your small automation sytems? Twido programmable controllers and TwidoSuite software provide simple and astute solutions for all your

More information

Crow Limited Warranty. Print Version 017

Crow Limited Warranty. Print Version 017 Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose

More information

Modbus and ION Technology

Modbus and ION Technology 70072-0104-14 TECHNICAL 06/2009 Modbus and ION Technology Modicon Modbus is a communications protocol widely used in process control industries such as manufacturing. PowerLogic ION meters are compatible

More information

Connecting to the Internet

Connecting to the Internet Connecting to the Internet Connecting the Gateway to the Internet Configuration of TCP/IP Protocol Installing the USB Drivers Connecting Ethernet Network Devices Connecting USB Network Devices Connecting

More information

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual Section 1: Introduction SECURITY WARNING: New SEG's shipped after April 2008 will have Telnet setup option enabled by

More information

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument. TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as

More information

Equinox L5300 Installation and Configuration Guide Version 1.0 Innovative Payment Processing Solutions for Businesses

Equinox L5300 Installation and Configuration Guide Version 1.0 Innovative Payment Processing Solutions for Businesses January 2016 Equinox L5300 Installation and Configuration Guide Version 1.0 Innovative Payment Processing Solutions for Businesses Contents 1. Terminal Installation... 3 1.1 Terminal Installation Ethernet

More information

SOP085 - HELLER OVEN SOFTWARE INSTALLATION PROCEDURE. For version 6.2.x.x

SOP085 - HELLER OVEN SOFTWARE INSTALLATION PROCEDURE. For version 6.2.x.x SOP085 - HELLER OVEN SOFTWARE INSTALLATION PROCEDURE For version 6.2.x.x DATE REV ECN - DESCRIPTION OF CHANGE Initials 02/20/2014 INT ECN 140003-001 TP For version 6.2.x.x Rev. INT Page 1 of 16 Basic PC

More information

Getting Started with the Xilinx Zynq- 7000 All Programmable SoC Mini-ITX Development Kit

Getting Started with the Xilinx Zynq- 7000 All Programmable SoC Mini-ITX Development Kit Getting Started with the Xilinx Zynq- 7000 All Programmable SoC Mini-ITX Development Kit Table of Contents ABOUT THIS GUIDE... 3 ADDITIONAL DOCUMENTATION... 3 ADDITIONAL SUPPORT RESOURCES... 3 INTRODUCTION...

More information

1 PC to WX64 direction connection with crossover cable or hub/switch

1 PC to WX64 direction connection with crossover cable or hub/switch 1 PC to WX64 direction connection with crossover cable or hub/switch If a network is not available, or if it is desired to keep the WX64 and PC(s) completely separated from other computers, a simple network

More information

32 Transferring Projects and Data

32 Transferring Projects and Data 32 Transferring Projects and Data This Chapter explains how to transfer GP-Pro EX project files to the GP and how to transfer the project files stored on the GP to your PC. Please start by reading 32.1

More information

HP-1000 Powerline USB Adapter

HP-1000 Powerline USB Adapter HP-1000 Powerline USB Adapter User s manual BEFORE INSTALLATION Plan ahead the installation of your powerline network. Note: You will need at least two powerline adapters to create a powerline network.

More information

SVA025 Netcom2 FAQ Rev 1. Mitsubishi Netcom 2 FAQ

SVA025 Netcom2 FAQ Rev 1. Mitsubishi Netcom 2 FAQ SVA025 Netcom2 FAQ Rev 1 Mitsubishi Netcom 2 FAQ SVA025 Netcom2 FAQ Rev 1 2 What series of Netcom did we purchase? Netcom 2 FAQ Mitsubishi has several different versions of communications available. 1.

More information

Installing PowerLink on Windows 7 64-bit

Installing PowerLink on Windows 7 64-bit Instruction Manual Version 1.0, Code No. 20 751 806 1 Introduction... 3 2 Installing Virtual PC... 3 3 Configuring Windows XP Mode... 5 4 Installing Powerlink to Virtual XP... 8 5 Run PowerLink software

More information

Prestige 650R-31/33 Read Me First

Prestige 650R-31/33 Read Me First Prestige 650R-31/33 Read Me First Prestige Rear Panel Connections PORT DSL CONSOLE LAN 10/100M POWER Connect to a telephone jack using a telephone wire. CONNECTION Connect to a serial port (COM port) on

More information

HP-1000 Powerline Ethernet Adapter

HP-1000 Powerline Ethernet Adapter HP-1000 Powerline Ethernet Adapter User s manual BEFORE INSTALLATION Plan ahead the installation of your powerline network. Note: You will need at least two powerline adapters to create a powerline network.

More information

Linksys Gateway SPA2100-SU Manual

Linksys Gateway SPA2100-SU Manual Linksys Gateway SPA2100-SU Manual Manuel de l'utilisateur Table of Contents Looking for Basic Setup Instructions?... 3 Most Recent Version of this Manual... 3 Advanced Setup Instructions... 4 Wiring Your

More information

USB 3.0 to Gigabit Ethernet Adapter

USB 3.0 to Gigabit Ethernet Adapter USB 3.0 to Gigabit Ethernet Adapter User Manual Ver. 1.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3

More information

Using a simple crossover RJ45 cable, you can directly connect your Dexter to any computer.

Using a simple crossover RJ45 cable, you can directly connect your Dexter to any computer. Dexter is a network device using the Ethernet protocol to connect and communicate with other devices on the network: Computers, routers, DHCP servers. Thus you have to setup your Dexter and your network

More information

Config software for D2 systems USER S MANUAL

Config software for D2 systems USER S MANUAL DT-CONFIG SOFTWARE Config software for D2 systems USER S MANUAL CONTENTS 1. Introductions ------------------------------------------------------------------- 3 2. System Requirement and Connection ----------------------------------------

More information

Ethernet Radio Configuration Guide

Ethernet Radio Configuration Guide Ethernet Radio Configuration Guide for Gateway, Endpoint, and Repeater Radio Units April 20, 2015 Customer Service 1-866-294-5847 Baseline Inc. www.baselinesystems.com Phone 208-323-1634 FAX 208-323-1834

More information

S-SupremaConfigurationGuide-DOC 7/23/2014. Suprema Biometrics Configuration Guide ACS OnSite Aparato

S-SupremaConfigurationGuide-DOC 7/23/2014. Suprema Biometrics Configuration Guide ACS OnSite Aparato S-SupremaConfigurationGuide-DOC 7/23/2014 Suprema Biometrics Configuration Guide ACS OnSite Aparato Page 2 Suprema Configuration Guide ACS OnSite Aparato Table of Contents 1. SUPREMA BIOSTAR CONFIGURATION...

More information

UPS Network Interface. Quick InstallationGuide

UPS Network Interface. Quick InstallationGuide UPS Network Interface Quick InstallationGuide Version 1.1 March 1999 COPYRIGHT Copyright 1999 RINGDALE UK Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed,

More information

DSA-1000 / PRT-1000 Device Server / Thermal Printer

DSA-1000 / PRT-1000 Device Server / Thermal Printer LevelOne DSA-1000 / PRT-1000 Device Server / Thermal Printer User Manual V2.0 TABLE OF CONTENTS 1. INTRODUCTION...- 3-2. DEVICE OVERVIEW...- 7-3. HARDWARE SETUP...- 10-4. SYSTEM CONFIGURATION...- 12 -,

More information

BECKHOFF. Application Notes. www.beckhoffautomation.com. BC9000: Getting Started Guide. For additional documentation, please visit.

BECKHOFF. Application Notes. www.beckhoffautomation.com. BC9000: Getting Started Guide. For additional documentation, please visit. BECKHOFF Application Notes www.beckhoffautomation.com BC9000: Getting Started Guide BC-AppNote-002 1.0 27 August 2007 This application note is intended for the first time user of the BC9000 and TwinCAT

More information

CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program

CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program CNC File Transfer Box The CNC File Transfer connects a serial CNC device to the network so files can be easily transferred from a computer to the CNC equipment. Any computer on the network can transfer

More information

enervista UR Setup Software Quick Connect Instructions:

enervista UR Setup Software Quick Connect Instructions: enervista UR Setup Software Quick Connect Instructions: The user can connect to the UR relay via front serial port or rear Ethernet port using the Quick Connect feature of enervista UR Setup software.

More information

Setting up VPN Access for Remote Diagnostics Support

Setting up VPN Access for Remote Diagnostics Support Setting up VPN Access for Remote Diagnostics Support D. R. Joseph, Inc. supports both dial-up and Internet access for remote support of 3GIBC1 and LF-Sizer control systems. This document describes how

More information

DWL-2000AP. Before You Begin. Check Your Package Contents

DWL-2000AP. Before You Begin. Check Your Package Contents This product can be set up using any current web browser, i.e., Internet Explorer 6 or Netscape Navigator 6.2.3. DWL-2000AP D-Link AirPlus Xtreme G TM Wireless Access Point Before You Begin It s best to

More information

Read Me UNISTREAM AUTOMATION IDE

Read Me UNISTREAM AUTOMATION IDE Read Me UNILOGIC SOFTWARE UNISTREAM AUTOMATION IDE Unitronics UniLogic software is the programming Integrated Development Environment (IDE) you use to configure hardware, communications, and develop both

More information