TDP-136 TRANSCEIVER DATA PROGRAMMER
|
|
|
- Percival Anthony
- 9 years ago
- Views:
Transcription
1 TDP-136 TRANSCEIVER DATA PROGRAMMER PC SOFTWARE INSTALLATION & OPERATING INSTRUCTIONS Til Document No. 00RE277 Rev. A (Software V1.1x) NOV 2000 Technisonic Industries Limited 250 Watline Avenue, Mississauga, Ontario L4Z 1P4 Tel: (905) Fax: (905) E. Robinson Road, Suite 214, Amherst, New York Tel: (716) This document contains designs and other information which are the property of Technisonic Industries Ltd. Except for rights expressly granted by contract to the Canadian Government, or to the United States Government, this document may not, in whole or in part, be duplicated or disclosed or used for manufacture of the part disclosed herein, without the prior permission of Technisonic Industries Ltd.
2 bmaskclr>pctgqgml>r_`jcx>öéë>nnpcpuu pct n_ec bcqapgnrgml b_rc _nnpl A Section 2 (all pages) Change document to reflect operating instructions for R1V11 software.. fix GD1/GD2 upload. support print to file NOV 2000 R.K. Technisonic Industries Limited 250 Watline Avenue, Mississauga, Ontario L4Z 1P4 Tel: (905) Fax: (905) E. Robinson Road, Suite 214, Amherst, New York Tel: (716) ii
3 Table of Contents Section Introduction Description Minimum System Requirements Section Software Installation Windows 95* Windows 98* Windows NT 4.0* Hardware Installation Section General Getting Started Graphical User Interface (GUI) Basic Information Frame Rx Information Frame Tx Information Frame Memory Channel Summary Frame File Functions Frame Data Transfer Functions Frame Erase/Purge Functions Frame COM Port Selector Frame RS-232 Serial Technical Data Table of Figures Section Figure 2-1. The Install Program Icon Button Figure 2-2. The TDP-136 Data Cable Figure 2-3. The Data Cable Wiring Diagram Section Figure 3-1. TDP-136 Program Window Figure 3-2. Program Title Bar Figure 3-3. Basic Information Frame Figure 3-4. Basic Information - DEF Figure 3-5. Rx (Receive) Information Frame Figure 3-6. Tx (Transmit) Information Frame Figure 3-7. Memory Channel Summary Frame Figure 3-8. Memory Channel Summary Header Figure 3-9. Save and Erase Check Box Figure File Manipulation User Controls Figure Data Transfer Controls Figure Erase and Purge Controls Figure COM Port Selector * Microsoft, Windows 95, Windows 98, Windows NT, and Internet Explorer are registered trademarks of Microsoft Corporation. iii
4
5 SECTION 1 GENERAL DESCRIPTION 1.1 Introduction This publication provides operating and installation information on the TiL Transceiver Data Programmer for the TDFM-136 (TDP-136). The TDP software allows a standard PC to retrieve data from a connected TDFM-136 transceiver, for editing, storing, and sharing with other TDFM-136 transceivers. With the TDP software, you can create, save and print archives of the TDFM-136 channel settings. 1.2 Description The TiL TDP-136 software is a 32 bit Windows application that will work under Windows 95, Windows 98 and Windows NT 4.0. Please see the next section for specific details on your particular installation. 1.3 Minimum System Requirements Windows 95 - Intel 486 or compatible based PC - Windows 95 with the latest Service Releases/Packs installed (Installation of Microsoft Internet Explorer 5.0 or any Microsoft application more recent than mid 1998, will have automatically updated the required system files.) - Mouse - SVGA 800 x 600 Screen resolution - 5MB free Hard-Disk space - One available properly configured RS-232 serial (COM) port or Windows 98 - Intel or compatible Pentium class PC - Windows 98 with the latest Service Releases/Packs installed - Mouse - SVGA 800 x 600 Screen resolution - 5MB free Hard-Disk space - One available properly configured RS-232 serial (COM) port or Windows NT Intel or compatible Pentium class PC - Windows NT 4.0 with at least Service Pack 4 installed (Installation of Microsoft Internet Explorer 5.0 or any Microsoft application more recent than mid 1998, will have automatically updated the required system files.) - Mouse - SVGA 800 x 600 Screen resolution - 5MB free Hard-Disk space Technisonic Industries Ltd. 1-1
6
7 SECTION 2 INSTALLATION INSTRUCTIONS 2.1 Software Installation Before the TDP software can be installed, all the minimum computer system requirements outlined in the previous section must be met, or you will have difficulty installing or operating the software. The Installation procedures outlined in this document, assume some basic working knowledge of at least one of Microsoft s Windows 95/98/NT operating systems. NOTE: At any point during installation, if any Dialog Boxes pop up exclaiming that newer system files are about to be overwritten by older files, click on NO to skip overwriting newer files Windows 95 If your computer does not have Microsoft Internet Explorer 5.0 or any other Microsoft application, no later than mid 1998 installed, then it is possible that certain essential system files are outdated. If these system files are outdated your system will not meet the minimum requirements for installing and operating a large variety of new software including the TDP software. If your computer DOES meet the minimum requirements, you may proceed to step To update Windows 95, you will need to install an update available on Microsoft s website, called DCOM95 (dcom95.exe). To download DCOM95, just enter this (current) Internet URL for the file in your location bar in your Internet Browser. Your Browser will invoke a SAVE AS dialog box for you to save the file. Keep track of where you place it, as you will be required to locate it and RUN it. Conveniently, the file will fit on a regular IBM Formatted 3½ 1.44MB floppy disk, for easy transport and distribution. If you have the DCOM95.EXE update file on a floppy disk, copy/place it in a temporary location on your Hard-disk. 2. RUN DCOM95 by locating and double-clicking on it in Windows Explorer. Any System files on your computer that are OLDER than the ones contained in the DCOM95 update, will be replaced. You will be asked to restart your computer. Do so, and when the computer has finished booting, you will have an updated Operating System that will meet the requirements of the Transceiver Data Programmer software. 3. To install the TDP software, locate SETUP.EXE on the CD-ROM in Windows Explorer. When you have located it, double-click it to start the setup process. Technisonic Industries Ltd. 2-1
8 00RE277 TDP-136: Transceiver Data Programmer The setup wizard may or may not ask to reboot the computer, depending on which components your system required from the installation package. If so, let the computer restart and run setup again to complete the installation process. No further reboots will be required. 4. After setup finishes unpacking the software, a dialog box will pop up with the option to continue (by clicking on the icon button see Figure 2-1), exit the setup, or at this time you may choose an alternate location for the installation. If you have no objections to the default location just click on the icon button to continue the installation. 5. The TDP installation will ask what START menu Program Group you want the TDP software shortcut installed. Click FINISH if the default Program Group name is adequate. The Transceiver Data Programmer is now installed and ready to use with a TDFM Windows 98 Windows 98 comes pre installed with Internet Explorer 5.0 embedded into the operating system. As a result, the operating system as a whole meets the requirements for the installation and operation of the TDP software. 1. To install the TDP software, locate SETUP.EXE on the CD-ROM in Windows Explorer. When you have located it, double-click it to start the setup process. The setup wizard may or may not ask to reboot the computer, depending on which components your system required from the installation package. If so, let the computer restart and run setup again to complete the installation process. 2. After setup finishes unpacking the software, a dialog box will pop up with the option to continue (by clicking on the icon button see Figure 2-1), exit the setup, or at this time you may choose an alternate location for the installation. If you have no objections to the default location just click on the icon button to continue the installation. 3. The TDP installation will ask what START menu Program Group you want the TDP software shortcut installed. Click FINISH if the default Program Group name is adequate. The Transceiver Data Programmer is now installed and ready to use with a TDFM Windows NT 4.0 For a Windows NT 4.0 installation, a minimum of Service Pack 4 must be installed. If you do not have at least Service Pack 4, contact Microsoft for the most current Service Pack. 1. To install the TDP software, locate SETUP.EXE on the CD-ROM in Windows Explorer. When you have located it, double-click it to start the setup process. 2-2 Technisonic Industries Ltd.
9 TDP-136: Transceiver Data Programmer 00RE277 The setup wizard may or may not ask to reboot the computer, depending on which components your system required from the installation package. If so, let the computer restart and run setup again to complete the installation process. 2. After setup finishes unpacking the software, a dialog box will pop up with the option to continue (by clicking on the icon button see Figure 2-1), exit the setup, or at this time you may choose an alternate location for the installation. If you have no objections to the default location just click on the icon button to continue the installation. 3. The TDP installation will ask what START menu Program Group you want the TDP software shortcut installed. Click FINISH if the default Program Group name is adequate. The Transceiver Data Programmer is now installed and ready to use with a TDFM-136. Click on this ICON button to begin installation Figure 2-1. The Install Program Icon Button 2.2 Hardware Installation To interconnect the TDFM-136 to your PC, you must connect the 15 pin D connector of the Data Cable (TiL Part No ) to the TDFM-136, and the other end of the cable to an available Serial (COM) Port on your PC. The yellow (+) and green (-) wires that come out of the shell of the 15 pin D connector, are the power supply lines for the TDFM-136. In order for the TDFM-136 to operate, you must supply a minimum of 28 Volts (DC 1A capable min). Technisonic Industries Ltd. 2-3
10 00RE277 TDP-136: Transceiver Data Programmer 9 pin female 'D' connector goes to the 9 pin 'D' serial (COM) port on your PC...or pin 'D' connector goes to TDFM Volts (DC) is required on these supply lines to power the TDFM-136 Yellow wire is positive (+) Green wire is negative (-) If your computer does NOT have an available 9 pin serial COM port then this 25 pin female 'D' connector goes to 25 pin 'D' serial COM port on your PC Figure 2-2. The TDP-136 Data Cable NOTE: Do NOT connect both the 9 pin and 25 pin D connectors simultaneously. 2-4 Technisonic Industries Ltd.
11 TDP-136: Transceiver Data Programmer 00RE277 Figure 2-3. Data Cable Wiring Diagram If you do not have a TiL Data Cable , you may make your own as per Figure 2-3, or you may purchase a cable. Technisonic Industries Ltd. 2-5
12
13 SECTION 3 OPERATING INSTRUCTIONS 3.1 General This section contains instructions for the correct operation of the TDP-136 software, and explanations of the various parts and elements of the program s Graphical User Interface (GUI). NOTE: The following images are examples only, and may not reflect your particular data settings. 3.2 Getting Started To start the TDP-136 in Windows, simply click the Start menu > Programs > TiL Transceiver Data Programmer >TDP-136. The program should begin, and the following program window should open up. The current version number is in square brackets in the Title Bar. Figure 3-1. TDP-136 Program Window NOTE: Use of a mouse is highly recommended! It is possible however, to use the software by using the [Tab], [Shift]+[Tab] and cursor keys to navigate through the program interface. You will note that all the buttons have an underlined letter. By pressing the [Alt] key and the underlined letter, you can invoke that function. (eg: [Alt]+F, would save the file.) Technisonic Industries Ltd. 3-1
14 00RE277 TDP-136: Transceiver Data Programmer Figure 3-2. Program Title Bar For your convenience, the name of the currently opened data file, in this instance Userinfo.136, is shown in the Program Title Bar. No filename will be displayed on initial program startup. 3.3 Graphical User Interface (GUI) The window is broken up into 8 logical sections or frames. Basic Information, Rx Information, Tx Information, Memory Channel Summary, File Functions, Data Transfer Functions, Erase/Purge Functions, and COM Port Selector Basic Information Frame The Basic Information frame is where you enter or edit the basic information for a channel memory. The field information displayed includes: the current active channel for editing, the Scan List(s) that the current Channel is to be included in, the text Description assigned to that channel and the channel Operating Mode. Figure 3-3. Basic Information Frame A - The Channel box displays the currently active channel. Valid entries are DEF, 1 through 200, GD1, and GD2. If you like, you may directly enter the channel number you would like to edit into this box. Invalid characters will be ignored. B - The UP/DOWN buttons allow you to select the next or previous channel for editing. If you should scroll down past the lower channel limit (001), the channel will jump to GD2 and continue scrolling down from there. Inversely, if you should scroll up past the upper channel limit (GD2), the channel will jump to 001 and continue scrolling UP from there. This function is offered as a courtesy. C - The Scan List select boxes allow you to assign the current active channel to any, or a combination of any of the 5 available scan lists. 3-2 Technisonic Industries Ltd.
15 TDP-136: Transceiver Data Programmer 00RE277 D - The Description text box, allows for a name or label to be assigned to the current active channel. The label can be any arbitrary word up to 9 characters in length. Valid characters are 0 through 9, (lower-case) a through z, (upper-case) A through Z, (space),!,, #, $, %, and &. Invalid characters will be ignored. E - The Operating Mode pull-down list box, sets and/or displays the current mode of operation for the active channel. The options are Wide, Narrow, or Digital. Both Wide and Narrow are Analog operation functions. The pull-down box allows for selection but not direct entry. F - The Save Record button, will commit to the active channel, any changes done in the Basic Information, Rx Information, Tx Information frames. You will see the active channel data in the Channel Information Summary reflect the changes made. By clicking on the Save Record, the active channel will advance by one record. Figure 3-4. Basic Information Editing - DEFault G - When the current active Channel is DEF, You may edit the DEFault values of all information entered into the Basic Information, Rx information, and Tx Information frames. These entries will become the defaulted values pre-entered into all the fields of each frame for any active channel that has never been edited Rx Information Frame The Rx Information frame is where you enter or edit the receive parameters for the selected channel memory. Each field is explained below. Figure 3-5. Rx (Receive) Information Frame Technisonic Industries Ltd. 3-3
16 00RE277 TDP-136: Transceiver Data Programmer A - This Frequency box determines the receive frequency. The valid range is MHz to MHz, in 25 khz ( MHz) steps for Wide mode and 12.5 khz ( MHz) steps for Narrow and Digital modes. The program will ignore invalid characters. B - The Squelch Mode pull-down list box selects either Noise, CTCSS, or DCS (also known as DPL) modes for the TDFM-136 in Narrow or Wide (analog) modes. Refer to E in For Digital mode, the valid selections are Digital Clear, or Talk Group. Refer to E in The pull-down box allows for selection but not direct entry, and will not allow for incompatible mode selection. C - The Tones pull-down list allows for the selection of an industry standard tone frequency for the CTCSS squelch mode. The pull-down box allows for selection but not direct entry. D - The Codes pull-down list allows for the selection of an industry standard DCS code for the DCS squelch mode. The pull-down box allows for selection but not direct entry. E - The Talk Group box is used to assign a numeric identifier or serial number to the user for the P25 (digital) operating mode. This is a 4 character HEXADECIMAL number. Valid characters are 0 to 9 and A to F. All other characters will be ignored. F - The NAC (Network Access Code) box is used to assign a numeric identifier or serial number to the user for the P25 (digital) operating mode. This is a 3 character HEXADECIMAL number. Valid characters are 0 to 9 and A to F. All other characters will be ignored Tx Information Frame The Rx Information frame is where you enter or edit the transmit parameters for the selected channel memory. Each field is explained below. Figure 3-6. Tx (Transmit) Information Editing Window A - The Sx and Dx radio buttons, select either Simplex or Duplex operating modes. In Duplex (Dx) mode, the Tx Information may be entered independent of the settings of the Rx Information. 3-4 Technisonic Industries Ltd.
17 TDP-136: Transceiver Data Programmer 00RE277 B - In Simplex (Sx) mode, the Tx Information setting fields are grayed out, and none of the field values may be edited. All the values in the fields will be the same as those entered in the Rx Information frame. When you enter the information into each field in the Rx frame, the corresponding Tx field will display the same setting Memory Channel Summary Frame The Memory Channel Summary displays the currently stored settings for all the 202 memory Channels (1 to 200, GD1, and GD2). All of the information for each channel line represents the settings as defined in the Basic Information, Rx Information, and Tx Information fields. Figure 3-7. Memory Channel Summary Frame The up-down scroll bar on the right will allow you to quickly move to the desired channel in the summary window. As a convenience, the selected channel will automatically center itself in the window (where possible). And will become the active channel displayed in the Edit frames/fields above. As a convenience, the TDP software will keep track of and display whether the Channel entry was programmed in Simplex (Sx) or Duplex (Dx) modes. The editable channel default settings (defined as Def ) are shown at the top of the summary window, and remain there for quick reference, independent of the channel list position. You may also use the summary window to select the active channel for editing. By clicking anywhere on the line of any of the channels listed in the window, you will make that channel active for editing in the Basic Information, Rx Information, and Tx Information frames. If the Save Record button is clicked at any point after editing any active channel, the changed information is reflected for that channel in the summary window. Figure 3-8. Memory Channel Summary Window Header Technisonic Industries Ltd. 3-5
18 00RE277 TDP-136: Transceiver Data Programmer A - All information under this heading represents the Basic Information configuration for each of the 202 channels. See B - The Receive settings for the 202 channels are arranged in columns under this heading. See C - All the Transmit settings for the 202 channels are arranged in columns under this heading. See D - Chan represents the channel number (0 to 200, GD1 and GD2). E - Scan shows which scan list(s) each channel is currently assigned to. F - The Description is the alphanumeric label or name assigned by the user to the Channel. G - Mode indicates the spacing of the channel. n indicates narrow channel spacing (12.5 khz), the w indicates wide channel spacing (25 khz) and D indicates Digital operating mode. H - This is the receive Frequency assigned to the channel. I - Indicates the Squelch mode assigned to the receive function of the channel. In Noise and Digital Clear squelch mode, the mode will be indicated as Rx. In CTCSS mode, the mode will be indicated as Rt. The DCS squelch mode is identified as Rc. In digital mode, the Talk Group mode is identified as Rg. J - This is the user selected Tone assigned to the CTCSS function. K - Code is the user selected digital code assigned to the DCS function. L - Represents the unique identifier or serial number assigned to the Talk Group function for the Digital Mode. M - Represents the unique identifier or serial number assigned to the Network Access Code function for the Digital Mode. Note: I, J, K, L, and M represent the same data types for the Transmit Information. Figure 3-9. Save and Erase Check Box 3-6 Technisonic Industries Ltd.
19 TDP-136: Transceiver Data Programmer 00RE277 To the left of the Channel number, you will notice a column of check-boxes. These checkboxes indicate whether a channel s content data is to be saved, erased or ignored during the download process. A - The grayed check-box indicates a channel whose contents are to be erased from the connected TDFM-136 during download. B - The check-box indicates a channel whose data is to be updated in the connected TDFM- 136 during download. C - An empty check-box will do nothing during download. During the download process, the channel will be skipped over. (See C and D) File Functions Frame The File Functions Frame controls allow the user to manipulate the Transceiver Data Files for the TDFM-136 (filename.136). Figure File Manipulation Controls A - Save File will allow you to save the Current data set into a file with a name of your choosing. The filename may be any length up to 64 characters. A file extension of.136 will be automatically appended to the filename. (eg: Dataset1.136) B - Open File will bring up the Open dialog box to allow you to select an existing.136 file to load. C - The Print List function will print all the contents of all the 202 (1 to 200, GD1, and GD2) channels, as presented in the Memory Channel Summary window. As a convenience, the description header will be printed at the top of each page. D - The Print to File option will create a text file of the entire channel list, as presented in the Memory Channel Summary window. The text file may then be inserted into your documentation. Technisonic Industries Ltd. 3-7
20 00RE277 TDP-136: Transceiver Data Programmer Data Transfer Functions Frame The Data Transfer Functions frame is where you send data to, or receive data from, the TDFM-136 transceiver. Each button is explained below. Figure Data Transfer Controls NOTE: Industry standard defines Download as the RECEIVING function, and Upload as the SENDING function. In the TDP-136 however, the button nomenclature has been worded to coincide with the TDFM-136 s function. You will invoke the SAME function name on the TDFM-136 and the TDP-136 software. A - The Upload (from Radio) button instructs the TDP-136 program to wait for and read in the channel data from the TDFM-136 connected to the Computer s COM Port. ** IMPORTANT: You must click this BEFORE instructing the connected TDFM-136 to SEND the channel data ** B - The Download (to Radio) button instructs the TDP-136 program to send the channel data from the TDFM-136 connected to the Computer s COM Port. ** IMPORTANT: You must click this AFTER instructing the connected TDFM-136 to wait for channel data ** C - Select All marks all channels for download to the TDFM-136. In the Channel Summary window, all channels will be marked with a to the left of the channel number. All channel data will be updated to the TDFM-136 connected to the PC, during the download process. D - Clear All un-selects all channels in the Channel Summary window. Any channel marked with a will NOT be updated during the Download process Erase/Purge Functions Frame The erase and purge functions allow you to erase selected memory channels (Erase) or to remove all data from the radio and reset it to FACTORY SETTINGS (Purge). The functions may be selected or de-selected in the TDP software as desired, the actual data in the Transceiver is not affected until the command is transferred to the unit using the Download command. NOTE: Once the command has been sent to the Transceiver, the previous information CANNOT be restored using the UnErase or UnPurge functions. 3-8 Technisonic Industries Ltd.
21 TDP-136: Transceiver Data Programmer 00RE277 Figure Erase and Purge user Controls A - By clicking on the Un/Erase Current, you will mark the currently active channel for erasing. The contents of the channel in the Channel Summary window will be replaced with the word ERASED. The channel will also be marked with the grayed out ( ) check-box. During the download process, the contents of channels marked for erase will be erased on the connected TDFM-136. This is a toggle function. If you click Un/Erase Current again, the previous data contents for the currently active channel will be restored in the TDP Software only (see the note above) Because of the nature of the TDFM-136, channels 001, GD1 and GD2 MAY NOT be empty or erased. If you click the Un/Erase Current button while either of the channels is active, the program will display an error message to alert you of this. B - The Purge function, effectively resets the TDFM-136 to AS SHIPPED from the FACTORY. This function erases the entire contents of the TDFM-136, and resets channels 001, GD1 and GD2 to the factory defaults. Use this function to quickly erase and reset the transceiver. All the channels will be marked with a. All the Channel data in the Channel Summary window will be replaced with the words ERASED. The Purge command will be executed upon Download ONLY. C - Purge is a toggle function. When the Purge button is pressed, it becomes an UnPurge function. By clicking this UnPurge function, all the channel data for each of the Channels in the Channel Summary window will be restored IN THE TDP SOFTWARE ONLY you CANNOT UnPurge the Transceiver Data once the command has been sent COM Port Selector Frame This selects the COM (RS-232 Serial communications) port on your computer, to which the TDFM-136 is connected. Figure COM Port Selector Technisonic Industries Ltd. 3-9
22 00RE277 TDP-136: Transceiver Data Programmer On ANY computer manufactured after 1990, COM 1 is typically a 9 pin male D connector. COM 2 may be either a 9 pin male or 25 pin male D connector. COM 3 and COM 4 are available in the TDP-136 software as a valid option, although they typically exist only in a computer with a third party Serial Card installed. Any time you select a COM port, the selection is saved automatically. Next time the TDP-136 software is run, the COM port you chose, will be selected. NOTE: The TDP-136 software assumes you have an available, properly configured COM port RS-232 Serial Technical Data The TDP-136 software communicates with the TDFM-136 transceiver at 9600 Baud 8 Data bits, No parity and 1 Stop bit. The TDP software is preset to this configuration and therefore the settings are not user definable Technisonic Industries Ltd.
Vicon Flash Upgrade Software
INSTRUCTION MANUAL Notes Refer to XX134 NO. XX134-13-01 REV. 1212 Vicon Flash Upgrade Software It is possible to upgrade software for the SurveyorVFT and Surveyor -Mini Camera Domes through a PC using
SharpdeskTM R3.1. Installation Guide Version 3.1.01
SharpdeskTM R3.1 Installation Guide Version 3.1.01 1 Copyright 2000-2004 by Sharp Corporation. All rights reserved. Reproduction, adaptation or translation without prior written permission is prohibited,
File Management Utility. T u t o r i a l
File Management Utility T u t o r i a l Contents System Requirements... 2 Preparing Files for Transfer to GlobalMark... 2 Application Launch... 2 Printer Setup... 2 Communication Status... 4 Communication
Vicon Flash Upgrade Software
NOTES NO. REV. SEC. INSTRUCTION MANUAL Refer to XX134-11-00 1108 3 XX134 Vicon Flash Upgrade Software It is possible to upgrade software for the SurveyorVFT through a PC using the Flash Upgrade software.
History of Revisions. Ordering Information
No part of this document may be reproduced in any form or by any means without the express written consent of II Morrow Inc. II Morrow, Apollo, and Precedus are trademarks of II Morrow Inc. Windows is
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide
Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide Hypercom Corporation 8888 East Raintree Drive Scottsdale, Arizona 85260 USA Corporate Telephone: 480.642.5000 Corporate
Model 288B Charge Plate Graphing Software Operators Guide
Monroe Electronics, Inc. Model 288B Charge Plate Graphing Software Operators Guide P/N 0340175 288BGraph (80207) Software V2.01 100 Housel Ave PO Box 535 Lyndonville NY 14098 1-800-821-6001 585-765-2254
Manual. Danfoss Central Station Communications Software Version 3
Manual Danfoss Central Station Communications Software Version 3 RS.8A.Q1.02 1-2001 Contents Introduction 4 System Overview 4 Minimum and Recommended Hardware Requirements 4 Using the Keyboard to Select
MS830 / MS833 Barcode Reader v1.0 9-December-2014
MS830 / MS833 Barcode Reader v1.0 9-December-2014 Publication Information 2014 Imagine Communications Corp. Proprietary and Confidential. Imagine Communications considers this document and its contents
Operating Instructions
Operating Instructions (For Setting up the Printer Driver and the Panasonic Document Management System) Digital Imaging Systems Model No. DP-800P / 800E / 806P Installation Table of Contents Installation
WinPFT File Transfer Utility (Catalog No. 2711-ND7)
Technical Data WinPFT File Transfer Utility (Catalog No. 2711-ND7) Overview WINPFT is a stand-alone Windows utility which lets you transfer applications developed for standard PanelView terminals or Dataliner
DUKANE Intelligent Assembly Solutions
PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc
BIGPOND ONLINE STORAGE USER GUIDE Issue 1.1.0-18 August 2005
BIGPOND ONLINE STORAGE USER GUIDE Issue 1.1.0-18 August 2005 PLEASE NOTE: The contents of this publication, and any associated documentation provided to you, must not be disclosed to any third party without
QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay
QUICK START GUIDE SG2 Client - Programming Software SG2 Series Programmable Logic Relay SG2 Client Programming Software T he SG2 Client software is the program editor for the SG2 Series Programmable Logic
SA-9600 Surface Area Software Manual
SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The
Signature Center Getting Started Guide
Signature Center Getting Started Guide 1113710 PRODUCED IN IRELAND Copyright 2010 McKesson Corporation and/or one of its subsidiaries. All Rights Reserved. This documentation is an unpublished work of
Device configurator DRC200
Operating manual 42/49-27 EN Engineer IT Device configurator DRC200 R&C Process Data Management Software Impressum Device configurator DRC200 Operating manual Document No. 42/49-27 EN Date of issue: 11.02
DIAL-UP DATA. User s Guide
DIAL-UP DATA User s Guide Iridium Satellite LLC Rev. 5; January 1, 2003 DIAL-UP DATA SERVICE--------------------------------------------------------------------------------------- TABLE OF CONTENTS 1 Dial-Up
Operating Instructions
Operating Instructions (For Setting Up) Digital Imaging Systems Installation Overview Model No. DP-8060 / 8045 / 8035 Table of Contents Setting Your Machine Installation Overview General Installation Overview...
AccXES Account Management Tool Administrator s Guide Version 10.0
AccXES Account Management Tool Administrator s Guide Version 10.0 701P41531 May 2004 Trademark Acknowledgments XEROX, AccXES, The Document Company, and the identifying product names and numbers herein
Control Technology Corporation CTC Monitor User Guide Doc. No. MAN-1030A Copyright 2001 Control Technology Corporation All Rights Reserved Printed in USA The information in this document is subject to
PORTABLE DATA COLLECTION TERMINAL
PORTABLE DATA COLLECTION TERMINAL WINDOWS TRANSFER UTILITY HELP FILES BETA EDITION Compsee, Inc. A Subsidiary of McRae Industries, Inc. 2 Welcome Thank you for using the Apex III Windows Transfer Utility
Brother Automatic E-Mail Printing OPERATION MANUAL
Brother Automatic E-Mail Printing OPERATION MANUAL Copyright Brother 1999 No part of this publication may be reproduced in any form or by any means without permission in writing from the publisher. The
Installing S500 Power Monitor Software and LabVIEW Run-time Engine
EigenLight S500 Power Monitor Software Manual Software Installation... 1 Installing S500 Power Monitor Software and LabVIEW Run-time Engine... 1 Install Drivers for Windows XP... 4 Install VISA run-time...
Kaspersky Password Manager
Kaspersky Password Manager User Guide Dear User, Thank you for choosing our product. We hope that you will find this documentation useful and that it will provide answers to most questions that may arise.
How to setup a serial Bluetooth adapter Master Guide
How to setup a serial Bluetooth adapter Master Guide Nordfield.com Our serial Bluetooth adapters part UCBT232B and UCBT232EXA can be setup and paired using a Bluetooth management software called BlueSoleil
OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher
OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout
Newton Backup Utility User s Guide. for the Windows Operating System
Newton Backup Utility User s Guide for the Windows Operating System K Apple Computer, Inc. 1995 Apple Computer, Inc. All rights reserved. Under the copyright laws, this manual may not be copied, in whole
Title Page. Installation Guide. PowerChute plus Version 5.0.1. for Windows 95
Title Page PowerChute plus Version 5.0.1 for Windows 95 Notice Page : PowerChute plus for Windows 95 version 5.0.1 PowerChute plus License Statement This software is protected by both United States copyright
STIM202 Evaluation Kit
Table of contents: 1 FEATURES... 2 2 GENERAL DESCRIPTIONS AND SYSTEM CONTENTS... 2 3 SYSTEM REQUIREMENTS... 2 4 GETTING STARTED... 3 4.1 INSTALLATION OF NI-SERIAL CABLE ASSEMBLY DRIVER... 3 4.2 INSTALLATION
Scan System (F) Operation Guide Set-up Edition
Scan System (F) Operation Guide Set-up Edition This Operation Guide mentions that 1650 is a 16 ppm (prints per minute) machine, 2050 is a 20 ppm (prints per minute) machine and 2550 is a 25 ppm (prints
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
Release Notes. R&S ZVH4/ZVH8 Cable and Antenna Analyzer
Release Notes Revision: 01 R&S ZVH4/ZVH8 Cable and Antenna Analyzer Firmware Release V1.50 These Release Notes describe the following models and options of the R&S Cable and Antenna Analyzer: R&S Cable
Software for Agilent Technologies Vector Series Network Analyzers
Using the Software Software for Agilent Technologies Vector Series Network Analyzers Software Overview The IntuiLink Vector Series Network Analyzer (VNA) software offers a set of connectivity tools that
CashFlow Programming Module CPM
CashFlow Programming Module CPM Installation & User Guide GB REV G4 08/08/2006 Table of Content Table of Content... 2 CashFlow Programming Module (CPM)... 4 What is a CPM?... 4 CPM Identification... 4
Xerox DocuPrint P12 Print Driver User Guide
Xerox DocuPrint P12 Print Driver User Guide Xerox Corporation 800 Phillips Road Webster, New York 14580 1998 Xerox Corporation. Xerox, The Document Company, the stylized X, and the identifying product
NDA-30141 ISSUE 1 STOCK # 200893. CallCenterWorX-Enterprise IMX MAT Quick Reference Guide MAY, 2000. NEC America, Inc.
NDA-30141 ISSUE 1 STOCK # 200893 CallCenterWorX-Enterprise IMX MAT Quick Reference Guide MAY, 2000 NEC America, Inc. LIABILITY DISCLAIMER NEC America, Inc. reserves the right to change the specifications,
Table of Contents. 1. Overview... 3. 1.1 Materials Required. 3 1.2 System Requirements. 3 1.3 User Mode 3. 2. Installation Instructions..
Table of Contents 1. Overview..... 3 1.1 Materials Required. 3 1.2 System Requirements. 3 1.3 User Mode 3 2. Installation Instructions.. 4 2.1 Installing the On Call Diabetes Management Software. 4 2.2
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
BIODEX. ATOMLAB 500/WIPE TEST COUNTER DATA MANAGER SOFTWARE Version 1.10 (and higher). OPERATION MANUAL 086-333
ATOMLAB 500/WIPE TEST COUNTER DATA MANAGER SOFTWARE Version 1.10 (and higher). OPERATION MANUAL 086-333 BIODEX Biodex Medical Systems, Inc. 20 Ramsey Road, Shirley, New York, 11967-4704, Tel: 800-224-6339
Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts
Rubbermaid Medical Solutions Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts REVISED FEBRUARY 25, 2010 Filename: Cart Interface Installation & Control Board
GUARD1 PLUS SE Administrator's Manual
GUARD1 PLUS SE Administrator's Manual Version 4.4 30700 Bainbridge Road Solon, Ohio 44139 Phone 216-595-0890 Fax 216-595-0991 [email protected] www.guard1.com i 2010 TimeKeeping Systems, Inc. GUARD1 PLUS
Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide
Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide Document Number: P0874391 Document Release: Standard 1.00 Date: November 1997 Year Publish FCC TM 1997 All rights reserved Printed in
GX-2009 Data Logger Management Program Operator s Manual
GX-2009 Data Logger Management Program Operator s Manual Part Number: 71-0163RK Revision: C Released: 3/19/12 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by
Software Installation Procedure (MS Windows)
Software Installation Procedure (MS Windows) E9970-96005 Rev. A 02/2004 (3070 05.30p 0603 WN) In this guide... Introduction, 1 Agilent 3070 Tech Support Web Site, 2 Time for Installation, 2 PC Specifications
Upgrading from Call Center Reporting to Reporting for Call Center
Upgrading from Call Center Reporting to Reporting for Call Center www.nortelnetworks.com 2003 Nortel Networks i Table of Contents Table of Contents Change History...1 How to use this guide...2 Introduction...
Real Time Monitor. A Real-Time Windows Operator Interface. DDE Compliant. (for remote data display)
Real Time Monitor A Real-Time Windows Operator Interface DDE Compliant (for remote data display) TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 INSTALLATION...2 1.2 FIRST START UP - DDE CONFIGURE...2 1.3 AUTO-STARTUP...2
CNC Transfer. Operating Manual
Rank Brothers Ltd CNC Transfer Operating Manual Manufactured by: Rank Brothers Ltd 56 High Street, Bottisham, Cambridge CB25 9DA, England Tel: +44 (0)1223 811369 Fax: +44 (0)1223 811441 Website: http://www.rankbrothers.co.uk/
ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4
ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 1 PURPOSE:... 1 2 CPM-4/CPM-2 COMPATIBILITY... 2 2.1 NETWORK CABLES... 2 2.2 FACTORY DEFAULT SETTINGS... 2 2.3 CHANGING THE RS-232 SERIAL PORT BAUD
PC Programming Manual KX-TA/TES/TEM824. Advanced Hybrid System. Model No.
WANET TELECOMS LIMITED Plot 53, Jinja Road Kampala Uganda Tel: +256 392 904 691 : +256 793 846 923 FAX: +1 414 978 7282 Email: [email protected] Website: www.wanetelecoms.com Advanced Hybrid System
Easy Setup Guide for the Sony Network Camera
-878-191-11 (1) Easy Setup Guide for the Sony Network Camera For setup, a computer running the Microsoft Windows Operating System is required. For monitoring camera images, Microsoft Internet Explorer
PARTNER ACS R4.0 Remote Administration R4.0. Getting Started
PARTNER ACS R.0 Remote Administration R.0 Getting Started 8-6-66 700080 Issue May 00 Copyright 00, Avaya Inc. Document 8-6-66 All Rights Reserved 700080 Printed in USA Issue May 00 Notice Every effort
AXIS Camera Station Quick Installation Guide
AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera
PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999
232 232232 PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999 Guarantee. FULL 36 MONTHS GUARANTEE. We guarantee your interface card for a full 36 months from purchase, parts and labour, provided it has been
Installing the Gerber P2C Plotter USB Driver
Installing the Gerber P2C Plotter USB Driver 1 You can install a Gerber P2C plotter using a USB connection and communicate with it using compatible design software. The following procedures describe installing
PC Program User s Guide (01.01.05) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming
Work Off-Line Set up a new database or modify a previously saved database (without being connected to the telephone system). This helps minimize on-site programming time. Work On-Line (connected directly
Getting Started with Vision 6
Getting Started with Vision 6 Version 6.9 Notice Copyright 1981-2009 Netop Business Solutions A/S. All Rights Reserved. Portions used under license from third parties. Please send any comments to: Netop
4 Backing Up and Restoring System Software
4 Backing Up and Restoring System Software In this Chapter... Planning a Backup Strategy, 4-3 Preparing for Disaster Recovery, 4-4 Creating Boot Recovery Diskettes, 4-5 Making a Full Backup Tape, 4-8 Restoring
CA XCOM Data Transport for Windows Server/Professional
CA XCOM Data Transport for Windows Server/Professional Installation Guide Release 11.6 Second Edition This Documentation, which includes embedded help systems and electronically distributed materials,
Getting Started with IntelleView POS Administrator Software
Getting Started with IntelleView POS Administrator Software Administrator s Guide for Software Version 1.2 About this Guide This administrator s guide explains how to start using your IntelleView POS (IntelleView)
Reporting for Contact Center Setup and Operations Guide. BCM Contact Center
Reporting for Contact Center Setup and Operations Guide BCM Contact Center Document Number: NN40040-302 Document Status: Standard Document Version: 04.00 Part Code: N0060637 Date: June 2006 Copyright 2005
Page 1 S5.5 Monitoring Software Manual Rev 1.2 for Software Ver 1.0
Trantec S5.5 Monitoring Software Manual Initial Setup Minimum PC Requirements 1.6 GHz CPU, 256 MB Memory, 1 available USB port, Windows XP Recommended PC >2.0 GHz CPU, 512 MB (XP) 1 GB (Vista) memory,
Installation and initial configuration of UI View32, with PMap Server 7 and Precision Mapping Streets and Traveler 8.0 on Microsoft Vista
Installation and initial configuration of UI View32, with PMap Server 7 and Precision Mapping Streets and Traveler 8.0 on Microsoft Vista Background: UI View is considered one of the best Automated Position
When upgrading your TAPIT software make sure that all call accounting data has been exported before you begin the installation process.
When upgrading your TAPIT software make sure that all call accounting data has been exported before you begin the installation process. Registration Settings: SERIAL NUMBER: COMPUTER ID: REGISTRATION NUMBER:
Ethernet Interface Manual Thermal / Label Printer. Rev. 1.01 Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2
Ethernet Interface Manual Thermal / Label Printer Rev. 1.01 Metapace T-1 Metapace T-2 Metapace L-1 Metapace L-2 Table of contents 1. Interface setting Guiding...3 2. Manual Information...4 3. Interface
Guest PC. for Mac OS X. User Guide. Version 1.6. Copyright 1996-2005 Lismore Software Systems, Ltd. All rights reserved.
Guest PC for Mac OS X Version 1.6 User Guide Copyright 1996-2005 Lismore Software Systems, Ltd. All rights reserved. Table of Contents About Guest PC... 1 About your Virtual Computer... 1 Creating a Virtual
Orbit PCI Mk 2 Network Card. User Manual. Part No. 502566 Issue 4
Orbit PCI Mk 2 Network Card User Manual Part No. 502566 Issue 4 Information in this document is subject to change without notice. Companies, names and data used in examples herein are fictitious unless
1 Intel Smart Connect Technology Installation Guide:
1 Intel Smart Connect Technology Installation Guide: 1.1 System Requirements The following are required on a system: System BIOS supporting and enabled for Intel Smart Connect Technology Microsoft* Windows*
footscan SCSI system Installation guide: balance software
footscan SCSI system Installation guide: balance software Doc nr RS-PRD-00137-01 PN 80000061 Page 1 Information in this guide is subject to change without notice. No part of this document may be reproduced
Serial ATA 2 Ports PCI Host
Serial ATA 2 Ports PCI Host This Manual is for the various Model of 2ports SATA HBA: Model A: Low Profile Serial ATA Internal 2 Ports Model B: Low Profile External 1 Port + Internal 1 Port Model C: Low
CentreWare Internet Services Setup and User Guide. Version 2.0
CentreWare Internet Services Setup and User Guide Version 2.0 Xerox Corporation Copyright 1999 by Xerox Corporation. All rights reserved. XEROX, The Document Company, the digital X logo, CentreWare, and
ADC SWATCH (v3.0) Switch Monitoring Software) User Manual)
ADC SWATCH (v3.0) Switch Monitoring Software) User Manual) Content Page INTRODUCTION... 1 Revision History... 1 Trademark Information... 1 1 OVERVIEW... 2 1.1 System Requirements... 2 2 INSTALLATION...
OfficeServ Link. User Guide. Version 2.1 June 2005
OfficeServ Link User Guide Version 2.1 June 2005 OfficeServ Link Version 2.1 User Guide This manual should be read before the installation and operation of the OfficeServ Link Software. COPYRIGHT This
SQL Server 2008 R2 Express Installation for Windows 7 Professional, Vista Business Edition and XP Professional.
SQL Server 2008 R2 Express Installation for Windows 7 Professional, Vista Business Edition and XP Professional. 33-40006-001 REV: B PCSC 3541 Challenger Street Torrance, CA 90503 Phone: (310) 303-3600
LevelOne MUS-1001. 1GB Smart Flash. User Manual V1.0.0-0610
LevelOne MUS-1001 1GB Smart Flash User Manual V1.0.0-0610 CONTENT CHAPTER 1 INTRODUCTION...4 1.1 About this Manual...4 1.2 Support Services...5 CHAPTER 2 PRODUCT OVERVIEW...6 2.1 Package Contents...6 2.2
Installation and Operating Instructions for the iks Aquastar Winsoft Demo-Software V0.1. System requirements
Installation and Operating Instructions for the iks Aquastar Winsoft Demo-Software V0.1 List of contents System requirements... 1 Installation... 2 Operation... 2 Connecting your PC to the iks aquastar...
InfoPrint 4247 Serial Matrix Printers. Remote Printer Management Utility For InfoPrint Serial Matrix Printers
InfoPrint 4247 Serial Matrix Printers Remote Printer Management Utility For InfoPrint Serial Matrix Printers Note: Before using this information and the product it supports, read the information in Notices
R ADVANCED MODEL-SETUP
M0008487C TYPE S R ADVANCED MODEL-SETUP Setup Software Preface Thank you for selecting our AC Servo Amplifier R ADVANCED MODEL. This User s Manual is a support tool explaining the use and specifications
Practice Fusion API Client Installation Guide for Windows
Practice Fusion API Client Installation Guide for Windows Quickly and easily connect your Results Information System with Practice Fusion s Electronic Health Record (EHR) System Table of Contents Introduction
OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com
OWNERS MANUAL Status Monitor for Windows 95, 98, ME, NT 4, 2000 & XP SIGNALCRAFTERS TECH, INC. www.signalcrafters.com 57 Eagle Rock Avenue, East Hanover, NJ 07936 Tel: 973-781-0880 or 800-523-5815 Fax:
Nero MediaStreaming for MCE Manual
Nero MediaStreaming for MCE Manual Nero AG Copyright and Trademark Information This manual and all its contents are protected by copyright and are the property of Nero AG. All rights reserved. This manual
NVIDIA Graphics Card and Driver Installation Guide (Windows NT 4.0 and Windows 2000)
NVIDIA Graphics Card and Driver Installation Guide (Windows NT 4.0 and Windows 2000) Revision 2.1 March 1, 2001 Published by NVIDIA Corporation 3535 Monroe Street Santa Clara, CA 95051 Copyright 2001 NVIDIA
Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.
Important Please read this User s Manual carefully to familiarize yourself with safe and effective usage. The latest software and User's Manual are available for download from our site: http://www.eizo.com
Software User Guide UG-461
Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment
Handheld LPC Data Retrieval Software for Windows. Operation Manual
Handheld LPC Data Retrieval Software for Windows MODEL S388-70 Operation Manual Read this manual carefully and understand the warnings described in this manual before operating the product. Keep this manual
PM1122 INT DIGITAL INTERFACE REMOTE
PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings
PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400
PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400 PePWave Surf Outdoor Series: Surf AP 200/400-X, PolePoint 400-X, Surf 400-DX User Manual Document Rev. 1.2 July 07 COPYRIGHT & TRADEMARKS
IMPORTANT! CPD 8424R1
IMPORTANT! You need to reinstall EPSON Image Authentication System (IAS) on your camera if it was installed before your camera was repaired. Please see your EPSON Image Authentication System User s Guide
Instruction manual. testo easyheat Configuration and Analysis software
Instruction manual testo easyheat Configuration and Analysis software en 2 General Information General Information This documentation includes important information about the features and application of
DIAL-UP DATA. User s Guide
DIAL-UP DATA User s Guide Iridium Satellite LLC Rev. 2; June 15, 2001 DIAL-UP DATA SERVICE--------------------------------------------------------------------------------------- TABLE OF CONTENTS 1 Dial-Up
Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.
TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as
Introduction 1-1 Installing FAS 500 Asset Accounting the First Time 2-1 Installing FAS 500 Asset Accounting: Upgrading from a Prior Version 3-1
Contents 1. Introduction 1-1 Supported Operating Environments................ 1-1 System Requirements............................. 1-2 Security Requirements........................ 1-3 Installing Server
DIRECT INTERNET DATA. User s Guide
DIRECT INTERNET DATA User s Guide Iridium Satellite LLC Rev. 2; June 15, 2001 DIRECT INTERNET DATA ------------------------------------------------------------------------------------- TABLE OF CONTENTS
M&C Software. for Windows. Windows-Based Monitor and Control Software for Comtech EF Data Satellite Terminals User s Guide
M&C Software for Windows Windows-Based Monitor and Control Software for Comtech EF Data Satellite Terminals User s Guide IMPORTANT NOTE: The information contained in this document supersedes all previously
Compuprint 4247 Serial Matrix Printers
Compuprint 4247 Serial Matrix Printers Remote Printer Management Utility for Serial Matrix Printers MAN10300-00.00 First edition (October 2011) This edition applies to the Compuprint 4247 printers and
PTPhoneManager II. User guide
COMMUNICATION AT ITS BEST PTPhoneManager II User guide Communications A member of PEIKER group DOCUMENT PEI TEL Communications GmbH - PTPhoneManager II - 2 - T ABLE OF CONTENTS Table of contents Table
User Manual. Thermo Scientific Orion
User Manual Thermo Scientific Orion Orion Star Com Software Program 68X637901 Revision A April 2013 Contents Chapter 1... 4 Introduction... 4 Star Com Functions... 5 Chapter 2... 6 Software Installation
Allworx OfficeSafe Operations Guide Release 6.0
Allworx OfficeSafe Operations Guide Release 6.0 No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopy,
Upgrading from Call Center Reporting to Reporting for Contact Center. BCM Contact Center
Upgrading from Call Center Reporting to Reporting for Contact Center BCM Contact Center Document Number: NN40010-400 Document Status: Standard Document Version: 02.00 Date: June 2006 Copyright Nortel Networks