Pressure drop in pipes...



Similar documents
Hydraulic losses in pipes

Experiment 3 Pipe Friction

ME 305 Fluid Mechanics I. Part 8 Viscous Flow in Pipes and Ducts

FLUID FLOW Introduction General Description

Pipe Flow-Friction Factor Calculations with Excel

4.What is the appropriate dimensionless parameter to use in comparing flow types? YOUR ANSWER: The Reynolds Number, Re.

LECTURE 1: Review of pipe flow: Darcy-Weisbach, Manning, Hazen-Williams equations, Moody diagram

L r = L m /L p. L r = L p /L m

Green Thread Product Data

Pacific Pump and Power

Darcy Friction Factor Formulae in Turbulent Pipe Flow

MATLAB AS A PROTOTYPING TOOL FOR HYDRONIC NETWORKS BALANCING

Minor losses include head losses through/past hydrants, couplers, valves,

Chapter 8: Flow in Pipes

Water hammering in fire fighting installation

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Calculating resistance to flow in open channels

Open Channel Flow. M. Siavashi. School of Mechanical Engineering Iran University of Science and Technology

Special Linings for unusual service conditions. Please contact ACIPCO.

Open channel flow Basic principle

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

Fluid Dynamics Basics

Theory, Application, and Sizing of Air Valves

Water Supply. Simulation of Water Distribution Networks. Mohammad N. Almasri. Optimal Design of Water Distribution Networks Mohammad N.

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

Experiment # 3: Pipe Flow

Chapter 13 OPEN-CHANNEL FLOW

= water horsepower WHP brake horsepower QH WHP = (222) ( 33,000 ft-lbs/min-hp)( gal/ft ) 1 HP=0.746 kw

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29

A drop forms when liquid is forced out of a small tube. The shape of the drop is determined by a balance of pressure, gravity, and surface tension

OUTCOME 3 TUTORIAL 5 DIMENSIONAL ANALYSIS

How To Understand Fluid Mechanics

Design of Sewage Pumping Stations by John Zoeller, PE, CEO/President

Fluid Flow in Pipes The Darcy-Weisbach Equation and the Fluid-Flow Calc v1.0 Tool for Engineers

Hydrant flow testing data provides important

Module 9: Basics of Pumps and Hydraulics Instructor Guide

Experiment (13): Flow channel

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

SIZING AND CAPACITIES OF GAS PIPING

Pipe Flow Expert. Verification of Calculation Results

Fluids and Solids: Fundamentals

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

What is the most obvious difference between pipe flow and open channel flow????????????? (in terms of flow conditions and energy situation)

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

AgoraLink Agora for Life Science Technologies Linköpings Universitet Kurs i Fysiologisk mätteknik Biofluidflöden

Practice Problems on Boundary Layers. Answer(s): D = 107 N D = 152 N. C. Wassgren, Purdue University Page 1 of 17 Last Updated: 2010 Nov 22

M6a: Open Channel Flow (Manning s Equation, Partially Flowing Pipes, and Specific Energy)

CE 6303 MECHANICS OF FLUIDS L T P C QUESTION BANK PART - A

HEAVY OIL FLOW MEASUREMENT CHALLENGES

Series 4000 Fiberglass Pipe and Fittings

Urban Hydraulics. 2.1 Basic Fluid Mechanics

For Water to Move a driving force is needed

CEE 370 Fall Laboratory #3 Open Channel Flow

Fluid Mechanics: Static s Kinematics Dynamics Fluid

FLUID FLOW STREAMLINE LAMINAR FLOW TURBULENT FLOW REYNOLDS NUMBER

Module 7: Hydraulic Design of Sewers and Storm Water Drains. Lecture 7 : Hydraulic Design of Sewers and Storm Water Drains

XI / PHYSICS FLUIDS IN MOTION 11/PA

Pipe Flow Experiments

Air-side Systems: Air Duct Design

Battery Thermal Management System Design Modeling

C. starting positive displacement pumps with the discharge valve closed.

Flow Assurance & Operability

Lecture 5 Hemodynamics. Description of fluid flow. The equation of continuity

Backwater Rise and Drag Characteristics of Bridge Piers under Subcritical

2 1/2 Pipe. 40 = height. the gauge pressure inside the vessel from the gauge pressure at the nozzle inlet as shown:

pressure inside the valve just before the final release of air. in pipeline systems resulting from 2p 1 p a m C D A o

Chapter 6 Work and Energy

Note: first and second stops will be reversed. Bring clothing and shoes suitable for walking on rough ground.

DEVELOPMENT OF A SOFTWARE TO DETERMINE THE EMITTER CHARACTERISTICS AND THE OPTIMUM LENGTH OF NEW DESIGNED DRIP IRRIGATION LATERALS

MIKE 21 FLOW MODEL HINTS AND RECOMMENDATIONS IN APPLICATIONS WITH SIGNIFICANT FLOODING AND DRYING

Distinguished Professor George Washington University. Graw Hill

Chapter 10. Open- Channel Flow

Appendix 4-C. Open Channel Theory

Automatic Sprinkler System Calculations

Pressure Drop in Air Piping Systems Series of Technical White Papers from Ohio Medical Corporation

Chapter 9. Steady Flow in Open channels

Experimentation and Computational Fluid Dynamics Modelling of Roughness Effects in Flexible Pipelines

2.0 BASIC CONCEPTS OF OPEN CHANNEL FLOW MEASUREMENT

PEERLESS PUMP COMPANY SYSTEM ANALYSIS FOR PUMPING EQUIPMENT SELECTION

Fundamentals of Fluid Mechanics

Introduction to Water Pipe Sizing

SIZING OF WATER PIPING SYSTEM

du u U 0 U dy y b 0 b

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)

Flow Measurement Options for Pipeline and Open Channel Flow

Kolmetz Handbook of Process Equipment Design. Piping Hydraulics Fluid Flow Line Sizing and Material Selection (ENGINEERING DESIGN GUIDELINE)

Centrifugal Fans and Pumps are sized to meet the maximum

SIZING AND CAPACITIES OF GAS PIPING

WINDER SYSTEMS GE Industrial Control Systems

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

A Comparison of Analytical and Finite Element Solutions for Laminar Flow Conditions Near Gaussian Constrictions

Before H 2 Town of South Windsor, CT Evaluates Large Diameter Concrete Pipe

BULLETIN NO. TEH-908. Bell & Gossett R T. Hydronic System Design with the Bell & Gossett System Syzer / ON GPM FLOW

RESISTANCE OF PE4710 PIPING TO PRESSURE SURGE EVENTS IN FORCE MAIN APPLICATIONS

CE 204 FLUID MECHANICS

C B A T 3 T 2 T What is the magnitude of the force T 1? A) 37.5 N B) 75.0 N C) 113 N D) 157 N E) 192 N

Transcription:

Pressure drop in pipes... PRESSURE DROP CALCULATIONS Pressure drop or head loss, occurs in all piping systems because of elevation changes, turbulence caused by abrupt changes in direction, and friction within the pipe and fittings. The most common methods used to determine the head loss in fiberglass pipe are Hazen-Williams, Manning and Darcy-Weisbach equations. The suitability of each method depends on the type of flow (gravity or pumped) and the level of accuracy required. Due to the smooth inside surface and the resistance to corrosion, ADPF fiber glass pipes have a relatively low head loss as compared to other material pipes. See Pressure loss versus flow rate curves. Hazen-Williams Equation The Hazen-Williams Equation is applicable to water pipes under conditions of full turbulent flow. It has gained wide acceptance in the water and wastewater industries because of its simplicity. v = 0.85 C R 0.63 J 0.54 v = velocity, m/s C = Hazen-Williams Coefficient R = Hydraulic mean radius, m J = Hydraulic gradient, m/m Hazen-William coefficient, C for ADPF fiber glass pipe is taken as 150. Manning Equation The Manning equation typically solves gravity flow problems where the pipe is only partially full and is under the influence of an elevation head only. v = (1/n) R 0.667 J 0.5 v = velocity, m/s n = Manning s Coefficient R = Hydraulic mean radius, m J = Hydraulic gradient, m/m Manning s Coefficient, n for ADPF fiber glass pipe is taken as 0.01 Darcy-Weisbach Equation It states that pressure drop is proportional to the square of the velocity and the length of the pipe. This equation is valid for all fluids in both laminar and turbulent flow. The disadvantage is that the Darcy- Weisbach friction factor is a variable. J = ( f.l.v²)/2.g.d J = Head loss, m g = Gravity constant, 9.81 m/s² v = Velocity, m/s D = Inside diameter, m f = Friction factor L = Length of the pipe, m The well known Reynolds number equation is used to characterize the fluid flow.

Re = v.d / ν where ν= Kinematic viscosity, m²/s The table given below determines the type of flow of fluid from the Reynolds number Type of Flow Reynolds Number Laminar Flow Re 2,000 Transition Flow Zone 2,000 Re 4,000 Turbulent Flow Re 4,000 If the flow is Laminar, f = 64 / Re If the flow is Turbulent, the friction factor can be determined from the Moody diagram found in most fluid mechanics texts or calculated from the Colebrook equation. ε = Long term absolute roughness. Re = Reynolds number The Colebrook friction factor for ADPF fiber glass pipe is determined as 0.04 mm including head losses over joints.

Pressure drop in fittings... Head Loss in Fittings is frequently expressed as the equivalent length of pipe that is added to the straight run of pipe as shown below. This approach is used most often with the Hazen-Williams or Manning s equations. The approach does not consider turbulence and subsequent losses created by different velocities. EQUIVALENT LENGTH IN METERS 150 200 250 300 350 400 450 500 600 700 800 900 1000 90 Elbow 8.5 6.4 7.9 9.4 10.7 12.2 14.0 17.0 23.0 28.0 32.4 37.1 42.3 45 Elbow 3.5 3.4 4.2 5.0 5.7 6.5 8.2 10.9 13.6 16.2 20.1 23.5 25.6 Tee 11.0 14.4 17.8 21.1 24.0 27.5 32.8 38.3 49.5 61.5 72.9 84.6 96.8 When more accuracy is required, head loss in fittings can be determined using loss coefficients (Kfactors) for each type of fittings. In this approach K-factor is multiplied by the velocity head of the fluid flow. H = K (v²/2g) H = Head loss, m V = Velocity of flow, m/s K-FACTOR FOR GRP FITTINGS Type of Fitting K-Factor 90 Elbow, standard 0.5 90 Elbow, single miter 1.4 90 Elbow, double miter 0.8 90 Elbow, triple miter 0.6 45 Elbow, standard 0.3 45 Elbow, single miter 0.5 Tee, straight flow 0.4 Tee, flow to branch 1.4 Tee, flow from branch 1.7 Reducer, single reduction 0.7

Surge pressure (Water Hammer)... Pressure surge or Internal shock, known commonly as water hammer, results from abrupt change of velocity within the system. Under certain conditions, these shock forces can reach magnitude sufficient to rupture or collapse a piping system, regardless of the material of construction. The transient pressure is the rapidly moving wave which increases and decreases the pressure in the system depending on the source of the transient and direction of wave travel. Rapid valve closure can result in the build-up of shock waves due to the conversion of kinetic energy of the moving fluid to potential energy which must be accommodated. These pressure waves will travel throughout the piping system and can cause damage far away from the wave source. The magnitude of the water hammer depends on, Fluid properties Velocity of flow Modulus of Elasticity of the pipe material Length of the pipe line and Speed in which the momentum of the fluid changes The low modulus of elasticity of fiberglass contributes to a self dampening effect as the pressure wave travels through the piping system. The magnitude of pressure wave in a metallic piping system is much higher due to the higher modulus of elasticity of these materials. In addition to rapid valve closure or opening, sudden air release and pump start up or shut down can create water hammer. Talbot formula gives: a=wave velocity (ft/s) P = Surge Pressure (psi) v = Change in flow velocity (ft/s) w = Density of fluid (lb/ft³) SG = Specific gravity of fluid K = Bulk modulus of fluid (psi) E = Hoop modulus of elasticity (psi) d = Inside diameter of pipe (inch) t = Pipe wall thickness (inch) g = Acceleration due to gravity (ft/s²) Good design practice usually prevents water hammer in most systems. Installation of valves which cannot open or close rapidly is one simple precaution. In addition, pumps should never be started into empty discharge lines unless slow opening mechanically actuated valves can increase the flow rate gradually. Check valves on pumps should close as quickly as possible to minimize the velocity of fluid flowing back. In some cases, thoroughly anchoring the piping system may mitigate this problem. In other cases, mechanical valve operators, accumulators, or feedback loops around pumps may have to be used to remove the source of water hammer.

Head Loss Charts...