Current distribution Comb busbars for Declic and SFT residential devices



Similar documents
P System Cubicles. Certified for more safety

know-how Giant in distributing electricity for industry Prisma GK

Functional system Prisma P

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

SAFETY ALERT SWITCHBOARD INTERNAL SEGREGATION AND IP RATING. May 2014 BACKGROUND

Securing your electrical installations Prisma,

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Providing Consulting Engineers and Switchboard Builders the BUILDING BLOCKS for advanced & cost effective solutions TECHNO MODULAR SWITCHBOARD SYSTEM

Distribution Boards & Consumer Units

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

The power distribution board that sets new standards

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

The range of rail-mounted terminal blocks. for a perfect electrical installation.

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

How To Build A Low Voltage Capacitor Lvcp

The complete range of consumer switchboards and switchgear

Automation Products. Low Voltage Switchgear MNS System Overview

The complete guide to Low Voltage switchgear

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

MNS is Switchgear System Technical Overview

The all-in-one residential network. Delta 8. Access to TV, radio, phone and data in every room

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

SENTRON Switching and Protection Devices Air Circuit Breakers

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

R.C.C.B. s two-pole LEXIC

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Unified requirements for systems with voltages above 1 kv up to 15 kv

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

2 The installation system

Electronic overload relay EF19 and EF45

How To Choose A Transformer

Current transformer selection guide

Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World

ZS10 Screw Clamp Terminal Block

Switchboard system. NorLine 800

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Electronic overload relay EF65, EF96 and EF146

5.2. Overview. The better method to install solderless compression connectors on power cable

MEDIUM VOLTAGE SWITCHGEAR AND CONTROLGEAR MODEL MS-E. IEC /12 /15 kv 25, 31.5, 40 ka

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

TriLine ASSEMBLY System PowerModules

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Relay mounting systems

Industrial Process Plants. Residential & Commercial Buildings. Roads & Tunnels. Airports & Seaports

References Control and signalling units Ø 22 0

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

FUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue SOCOMEC. Fuse combination switches

Command Control. D Command Control. Fuse Switches I.1 - STI isolatable fuse-carriers... D 2 I.2 - SBI fuse-carriers... D 4.

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

TX OPEN RS232/485 module

Tape Wound, Split Core and Ebony Current Transformers

Control and Signalling Units

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS

Block width on rail (mm) Standard block* is shown on blue background

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Current transformers (CT) & Shunts

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

Comparative study for cables and busbars

Medium voltage insulator

Power Meter Series 700

Trapezoidal-Connectors Series TMC

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

SIVACON The Versatile Low-Voltage Switchboard

Vario-Series Accessories

D-Line Contactors, Overload Relays and Accessories

Manual Motor Starter MS 116 up to 16 A Technical Data

IEC specifications for LV assembly switchboards

Jumper bar BJM. Assembled jumper bar BJD. Assembled jumper bar

Tape Wound, Split Core and Ebony Current Transformers

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

DEHNshield Application-optimised multipole combined lightning current and surge arrester

ASSEMBLED SOCKET-COMBINATIONS

Catalogue May EasyLine XLP Fuse Switch Disconnector pole

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

GE Power Controls. MiniFORM Switchboards

SIVACON Low Voltage Switchboard

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

MNS Low Voltage Switchgear System Guide

Electrical safety and protection devices

Measurement and Instrumentation

MV CABLE TYPE C

Power management. PowerLogic System. Catalogue 2004

GUIDE TO FORMS OF SEPARATION

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

MGE TM Galaxy TM 7000

Merlin Gerin Multi 9 System Protection Miniature Circuit Breakers

PC/104, PC/104 -Plus, VarPol connectors

LANC Fibre Patch Panel Solution

Transcription:

Current distribution Comb busbars for Declic and SFT residential devices Comb busbar, for connecting 26 x 9 mm modules, consisting of two insulated bars to supply 1P + N devices (Declic, SFT, etc.). Due to the small amount of space occupied by the comb busbars, the connection terminals on devices are easy to access. 047866 Bar clic Supply b by semi-rigid cable directly in the tunnel terminals of the device: v cross-section 16 for Declic v cross-section 10 for SFT b by semi-rigid cable via connector 14875: v cross-section 35 v cross-section 16 + 6 v cross-section 10 + 10. Electrical characteristics: b rated operating current: Ie (40 C): v 63 A with 1 central supply point v 90 A with 2 supply points b rated insulation voltage: 250 V b short-circuit withstand capacity: compatible with the breaking capacities of Merlin Gerin modular circuit breakers (1P + N). Choice of accessories Comb busbars Bar clic 14876 4 connectors for 35 mm 2 cables 14875 E40634 120E_5_0050.fm/2 3 octobre 2007 Schneider Electric

Comb busbars for DPN, SFT and C60 devices 043532 Range of comb busbars for 18 mm terminal spacing b supplied with two IP2 end-caps b markers can be fitted for circuit identification b cutting locations are marked on the copper bars and on the insulation b self-extinguishing insulating material, colour RAL 7016 b unused teeth may be insulated by fitting tooth-caps. 1P + N and 3P + N comb busbars Comb busbars For Declic, DPN, DPN N, SFT and STI 26-mod. comb 14880 1P + N Set of two 48-mod. comb 14890 3P + N Set of two 48-mod. comb 14899 Electrical characteristics b rated operating current: Ie (40 C): v 80 A with 1 central supply point v 100 A with 2 supply points b rated insulation voltage: 250 V b short-circuit withstand capacity compatible with the breaking capacities of Merlin Gerin modular circuit breakers. Connection Supply: b by semi-rigid cable: v 16 with DPN circuit breakers v 10 with SFT and STI devices, directly in their tunnel terminals b by 25 semi-rigid cable via connector 14885. Accessories For comb busbars Set of 40 end-caps 1P + N 14886 3P + N 14887 Set of 40 tooth-caps 1P + N and 3P + N 14898 E40635 N L1 L2 L3 3P + N comb busbar 14899. E40636 1P + N comb busbars make it possible to dismount Declic and DPN circuit breakers. Schneider Electric 3 octobre 2007 120E_5_0050.fm/3

Comb busbars for DPN, SFT and C60 devices (cont.) 030920 1P, 2P, 3P and 4P comb busbars Comb busbars For C60a/N/H/L, SFT, STI (except 3P +N) 1P 24-mod. comb 14881 108-mod. comb (L = 1 m) 14801 Set of two 48-mod. comb 14891 2P 24-mod. comb 14882 108-mod. comb (L = 1 m) 14802 Set of two 48-mod. comb 14892 3P 24-mod. comb 14883 108-mod. comb (L = 1 m) 14803 Set of two 48-mod. comb 14893 4P 24-mod. comb 14884 108-mod. comb (L = 1 m) 14804 Set of two 48-mod. comb 14804 Accessories For comb busbars Set of 40 end-caps 1P, 2P 14886 3P, 4P 14887 Set of 40 tooth-caps 1P, 2P, 3P, 4P 14888 Electrical characteristics b rated operating current: Ie (40 C): v 80 A with 1 central supply point v 100 A with 2 supply points b rated insulation voltage: 500 V (as per IEC 664) b short-circuit withstand capacity compatible with the breaking capacities of Merlin Gerin modular circuit breakers. Connection Supply: b by semi-rigid cable: v 25 with C60 circuit breakers (all ratings) v 10 with SFT and STI devices, directly in their tunnel terminals b by 25 semi-rigid cable via connector 14885. E40637 Tooth-caps may be fitted to insulate unused teeth. 030921 Connectors b compatible with SFT, STI, C60 comb busbars b clipped firmly onto insulated parts of comb busbars b can be fitted with Telemecanique clip-on markers for circuit identification. Connectors Set of 4 insulated connectors for 25 cables 14885 E40638 120E_5_0050.fm/4 3 octobre 2007 Schneider Electric

Comb busbars for DPN, SFT and C60 devices (cont.) 024706 100 A connection Flexible connection system, made of insulated copper cables (class 2: 1000 V insulation) with: b 6.9 x 2.5 mm ferrule crimped at one end for 16 tunnel terminals b 90 lugs with 8.5 mm holes crimped at the other end. Applications b direct connection between busbars at the rear of an enclosure and a comb busbar. 100 A connection L (mm) Set of four 100 A cables 420 07038 E40688 Direct connection between busbars at the rear of a Prisma G enclosure and a row of modular devices. Schneider Electric 3 octobre 2007 120E_5_0050.fm/5

NG125 NG125 References Comb busbars for NG25 054948 1P, 2P, 3P and 4P comb busbars Description b range of 1P, 2P, 3P and 4P comb busbars for 27 mm terminal spacing b length: v 432 mm (16 x 27 mm) for 1P, 2P and 4P comb busbars v 405 mm (15 x 27 mm) for 3P comb busbar b insulating material, colour grey RAL 7016 b IPXXB protection with tooth-caps b may be cut to length. Choice of comb busbars Comb busbars For NG125 1P 14811 2P 14812 3P 14813 4P 14814 The comb busbars are supplied with: b 8 tooth-caps + 2 end-caps for 2P comb busbars b 4 tooth-caps + 2 end-caps for 3P and 4P comb busbars. Accessories End-caps and tooth-caps 14818 comprising: b 20 tooth-caps b 4 end-caps for 2P and 3P comb busbars b 4 end-caps for 4P comb busbars. Electrical characteristics b rated operating current: Ie (40 C) = 125 A b maximum rated current per outgoing circuit: 63 A b rated insulation voltage: 690 V b rated impulse withstand voltage: Uimp = 8 kv b short-circuit withstand capacity compatible with the breaking capacities of Merlin Gerin modular circuit breakers. Connection Supply by cables with a maximum cross-section of 50 mm², directly in the tunnel terminals of the device. To supply the comb busbar from a busbar set located at the rear of the enclosure, use the 100 A prefabricated connection system (see page 120F_5_0055). E40639 MERLIN GERIN MERLIN GERIN I.ON I.ON Tooth-caps may be fitted to insulate unused teeth. 120E_5_0050.fm/6 3 octobre 2007 Schneider Electric

Schneider Electric 3 octobre 2007 120E_5_0050.fm/7