DEHNshield Application-optimised multipole combined lightning current and surge arrester

Size: px
Start display at page:

Download "DEHNshield Application-optimised multipole combined lightning current and surge arrester"

Transcription

1 DEHshield Application-optimised multipole Application-optimised prewired combined lightning current based on spark gap technology simply equipped electrical installations with reduced technical requirements For protecting residential buildings and special applications (see brochure o. DS13) Discharge capacity up to 50 ka (10/350 μs) o tripping of 32 A g/gg fuses up to shortcircuit currents of 25 ka rms by indicator flag in the inspection window For protecting low-voltage consumer's installations against surges and even direct lightning strikes. For installation in conformity with the lightning protection zones concept at the boundaries from 0 A 2. DEHshield TC 255: Application-optimised for T-C systems DEHshield TS 255: Application-optimised for T-S systems DEHshield TT 255: Application-optimised for TT and T-S systems ("31" circuit) DEHshield T 255: Application-optimised for single-phase T systems DEHshield TT 2P 255: Application-optimised for single-phase TT and T systems ("11" circuit) The space-saving and application-optimised DEHshield family offers various benefits that are characteristic of spark-gap-based Type 1 arresters such as the "wave breaker function" (WBF). This function and the associated reduction of the pulse time mitigate the energy of the lightning impulse current to an acceptable level for downstream protection stages or terminal equipment. Moreover, DEHshield arresters are directly energy coordinated with other arresters of the Red/ine product family. Application-optimised DEHshield and surge arresters combine lightning equipotential bonding up to 50 ka (10/350 μs) lightning impulse currents and surge protection in a single device. This clearly distinguishes DEHshield from varistor-based arresters of this application and performance class. Due to their technical parameters which are rated for use in simple and compact electrical installations, DEHshield arresters are ideally suited for this application class. For this reason, they are a space-saving and application-optimised solution in particular for residential buildings. DEHshield arresters also provide optimal protection in buildings without external lightning protection system where roof superstructures or overhead line supplies are installed. According to VdS 2031, it is advisable to use Type 1 SPDs for these buildings. A detailed application description can be found in brochure DS13. o additional backup fuse is required if an installation is protected by backup fuses up to 160 A. If applications are not sufficiently defined, it is advisable to use DEHventil. Fulfilling the most stringent technical requirements, DEHventil provides adequate protection at any time and is suitable for any application. The energy coordinated arresters even allow to protect terminal equipment if the distance between DEHshield and the consumers is 5 m. Owing to their non-exhausting spark gap and low space requirements, the application-optimised s can be easily integrated into distribution boards. The follow-current-limiting spark gap technology ensures selectivity even in case of low-value fuses (35 A g/gg), meaning that upstream fuses are not tripped by mains follow currents. Busbars and pin-shaped terminals from DEH SÖHE can be used for connecting DEHshield to other DI rail mounted devices. The type designation of DEHshield allows to easily choose the right arrester for the relevant system configuration of the low-voltage consumer s installation. The operating state/fault indication of every protective path immediately provides information on the operating state of the arrester even if no operating current is present. 40

2 DEHshield 30 DEHshield TC 2 (4 mods.) DSH TC 255 DSH TC Anwendungsopt. Kombiableiter DEHshield Typ 1 für dreiphasige T-C- Systeme Dimension drawing DSH TC 255 Basic circuit diagram DSH TC 255 Application-optimised prewired for T-C systems Type DSH TC 255 Part o SPD according to E / IEC /-11 ominal a.c. voltage (U ) 230 / 400 V ightning impulse current (10/350 μs) [-] (I total ) 3.5 ka Specific energy [-] (W/R) kj/ohms ightning impulse current (10/350 μs) [-] (I imp ) 12.5 ka Specific energy [-] (W/R) 3.06 kj/ohms ominal discharge current (8/20 μs) (I n ) 12.5 / 3.5 ka Voltage protection level (U P ) 1.5 kv Follow current extinguishing capability a.c. (I fi ) 25 ka rms Temporary overvoltage (TOV) (U T ) Operating temperature range (T U ) -40 C...80 C umber of ports 1 Cross-sectional area (,,, ) (min.) Cross-sectional area (,,, ) (max.) For mounting on 35 mm DI rail acc. to E 6015 Enclosure material thermoplastic, red, U 4 V-0 Capacity 4 modules, DI 43880

3 DEHshield DEHshield TS 30 2 (4 mods.) Basic circuit diagram DSH TS 255 Dimension drawing DSH TS 255 Application-optimised prewired for T-S systems DSH TS 255 DSH TS Anwendungsopt. Kombiableiter DEHshield Typ 1 für dreiphasige T-S- Systeme Type DSH TS 255 Part o SPD according to E / IEC /-11 ominal a.c. voltage (U ) 230 / 400 V ightning impulse current (10/350 μs) [-] (I total ) 50 ka Specific energy [-] (W/R) kj/ohms ightning impulse current (10/350 μs) [, -] (I imp ) 12.5 ka Specific energy [,-] (W/R) 3.06 kj/ohms ominal discharge current (8/20 μs) (I n ) 12.5 / 50 ka Voltage protection level [-]/[-] (U P ) 1.5 / 1.5 kv Follow current extinguishing capability a.c. (I fi ) 25 ka rms Temporary overvoltage (TOV) [-] (U T ) Operating temperature range (T U ) -40 C...80 C umber of ports 1 Cross-sectional area (,,,,,) (min.) Cross-sectional area (,,,,,) (max.) For mounting on 35 mm DI rail acc. to E 6015 Enclosure material thermoplastic, red, U 4 V-0 Capacity 4 modules, DI 43880

4 DEHshield 30 DEHshield TT 2 (4 mods.) DSH TT 255 DSH TT Anwendungsopt. Kombiableiter DEHshield Typ 1 f. dreiphasige TT-und T-S-Systeme Dimension drawing DSH TT 255 Basic circuit diagram DSH TT 255 Application-optimised prewired for TT and T-S systems ("31" circuit) Type DSH TT 255 Part o SPD according to E / IEC /-11 ominal a.c. voltage (U ) 230 / 400 V ightning impulse current (10/350 μs) [-] (I total ) 50 ka Specific energy [-] (W/R) kj/ohms ightning impulse current (10/350 μs) [-]/[-] (I imp ) 12.5 / 50 ka Specific energy [-]/[-] (W/R) 3.06 / kj/ohms ominal discharge current (8/20 μs) [-]/[-] (I n ) 12.5 / 50 ka Voltage protection level [-]/[-] (U P ) 1.5 / 1.5 kv Follow current extinguishing capability [-]/[-] (I fi ) 25 ka rms / 100 A rms Temporary overvoltage (TOV) [-] (U T ) Temporary overvoltage (TOV) [-] (U T ) 1200 V / 200 ms Operating temperature range (T U ) -40 C...80 C umber of ports 1 Cross-sectional area (,,,,,) (min.) Cross-sectional area (,,,,,) (max.) For mounting on 35 mm DI rail acc. to E 6015 Enclosure material thermoplastic, red, U 4 V-0 Capacity 4 modules, DI 43880

5 DEHshield DEHshield T 36 (2 mods.) Basic circuit diagram DSH T 255 Dimension drawing DSH T 255 Application-optimised prewired for single-phase T systems DSH T 255 DSH T Anwendungsopt. Kombiableiter DEHshieldTyp 1 für einphasige T- Systeme Type DSH T 255 Part o SPD according to E / IEC /-11 ominal a.c. voltage (U ) 230 V ightning impulse current (10/350 μs) [-] (I total ) 25 ka Specific energy [-] (W/R) kj/ohms ightning impulse current (10/350 μs) [, -] (I imp ) 12.5 ka Specific energy [,-] (W/R) 3.06 kj/ohms ominal discharge current (8/20 μs) (I n ) 12.5 / 25 ka Voltage protection level [-]/[-] (U P ) 1.5 / 1.5 kv Follow current extinguishing capability a.c. (I fi ) 25 ka rms Temporary overvoltage (TOV) [-] (U T ) Operating temperature range (T U ) -40 C...80 C umber of ports 1 Cross-sectional area (,,,) (min.) Cross-sectional area (,,,) (max.) For mounting on 35 mm DI rail acc. to E 6015 Enclosure material thermoplastic, red, U 4 V-0 Capacity 2 modules, DI

6 DEHshield DEHshield TT 2P 36 (2 mods.) DSH TT 2P 255 DSH TT 2P Anwendungsopt. Kombiableiter DEHshield Typ 1 für einphasige TT-und T-Systeme Dimension drawing DSH TT 2P 255 Basic circuit diagram DSH TT 2P 255 Application-optimised prewired for single-phase TT and T systems ("11" circuit) Type DSH TT 2P 255 Part o SPD according to E / IEC /-11 ominal a.c. voltage (U ) 230 V ightning impulse current (10/350 μs) [-] (I total ) 25 ka Specific energy [-] (W/R) kj/ohms ightning impulse current (10/350 μs) [-]/[-] (I imp ) 12.5 / 25 ka Specific energy [-]/[-] (W/R) 3.06 / kj/ohms ominal discharge current (8/20 μs) [-]/[-] (I n ) 12.5 / 25 ka Voltage protection level [-]/[-] (U P ) 1.5 / 1.5 kv Follow current extinguishing capability [-]/[-] (I fi ) 25 ka rms / 100 A rms Temporary overvoltage (TOV) [-] (U T ) Temporary overvoltage (TOV) [-] (U T ) 1200 V / 200 ms Operating temperature range (T U ) -40 C...80 C umber of ports 1 Cross-sectional area (,,,) (min.) Cross-sectional area (,,,) (max.) For mounting on 35 mm DI rail acc. to E 6015 Enclosure material thermoplastic, red, U 4 V-0 Capacity 2 modules, DI 43880

7 Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: 44 (0) Fax: 44 (0) Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.

Class I surge protection with sparkover gaps

Class I surge protection with sparkover gaps for low-voltage supplies surge protection with sparkover gaps Lightning conductors with sparkover gap for lightning protection or equipotential bonding providing class I According to the requirements of

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

wietap wietap Overvoltage Protection Tensions running high

wietap wietap Overvoltage Protection Tensions running high wietap wietap Overvoltage Protection Tensions running high 2 wietap wietap Overvoltage protection Important information on overvoltage The necessity of overvoltage protection on machines and systems as

More information

CATALOGUE SURGE PROTECTION LOW VOLTAGE

CATALOGUE SURGE PROTECTION LOW VOLTAGE CATALOGUE SURGE PROTECTION LOW VOLTAGE SALTEK, s.r.o. (limited liability company), is a Czech company specialising in the development and manufacture of surge protection devices (SPD). SALTEK offer a wide

More information

Surge protection for emergency alarm systems

Surge protection for emergency alarm systems Surge protection for emergency alarm systems White Paper Contents Lightning and surge protection for a burglar alarm system with pulse polling technology Lightning and surge protection for a fire alarm

More information

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

Lightning current simulation in the laboratory - parameters, procedures and test equipment - Lightning current simulation in the laboratory - parameters, procedures and test equipment - Dipl.-Ing. J. Schönau, Dr.-Ing. M. Naß, CE-LAB GmbH Prof. Dr.-Ing. F. Berger, Ilmenau University of Technology

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

The power of nature, the control of technology From ABB's experience, OVR PV: surge protection in photovoltaic plants

The power of nature, the control of technology From ABB's experience, OVR PV: surge protection in photovoltaic plants The power of nature, the control of technology From ABB's experience, OVR PV: surge protection in photovoltaic plants Made for the sun, threatened by atmospheric discharges The importance of surge protective

More information

SANS 10142-1 : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation

SANS 10142-1 : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation SANS 10142-1 : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation 4 Compliance Proof of Compliance (Sub clause 4.1.1) The SABS safety mark The SABS approved performance mark

More information

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions

More information

How can a charging station for electric vehicles be set up simply and safely?

How can a charging station for electric vehicles be set up simply and safely? SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,

More information

ELEMKO reserves the right to modify, add or remove any information included in this catalogue, if necessary. Every updated version of the catalogue

ELEMKO reserves the right to modify, add or remove any information included in this catalogue, if necessary. Every updated version of the catalogue ' EEMKO reserves the right to modify add or remove any information included in this catalogue if necessary Every updated version of the catalogue automatically cancels all the previous ones Photographs

More information

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection

More information

The complete range of consumer switchboards and switchgear

The complete range of consumer switchboards and switchgear Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Main catalog. System pro M compact Surge and lightning protection solutions with QuickSafe technology

Main catalog. System pro M compact Surge and lightning protection solutions with QuickSafe technology Main catalog System pro M compact Surge and lightning protection solutions with QuickSafe technology System pro M compact Surge and lightning protection solutions with QuickSafe technology Presentation

More information

Low Voltage Products. Switches Automatic Transfer Switches

Low Voltage Products. Switches Automatic Transfer Switches Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,

More information

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for. The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved

More information

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast. METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents

More information

Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants

Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants Introduction This document explains how to install Furse Electronic Systems s for mains power supplies: Single

More information

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. Ensuring operational continuity To ensure the operational continuity of an electrical

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

ABB - Pôle Foudre Soulé & Hélita OVR PLUS N1 40

ABB - Pôle Foudre Soulé & Hélita OVR PLUS N1 40 Presentation ABB - OVR PLUS N1 40 ABB France Lightning Protection Group All in one product SPDs with integrated back up protection are a solution that allow to have a complete surge protection design into

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

Charge Controller CC611/CC612 Preliminary datasheet

Charge Controller CC611/CC612 Preliminary datasheet Preliminary datasheet Preliminary datasheet CC61x_D00xxx_00_D_XXE_preliminary/04.2015 Product description The ender charge controller CC611 is the main component of a charging point and is designed for

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Lightning Arresters P30027 18 KVA P30038 10 KVA. Description & Installation

Lightning Arresters P30027 18 KVA P30038 10 KVA. Description & Installation Lightning Arresters P30027 18 KVA P30038 10 KVA Description & Installation Printed in USA 09/11 TO330 Rev. B Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT OVERVIEW 2 2.1 Intended Uses 2 2.2 Lightning

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

5SDD 92Z0401. Housingless Welding Diode. I FAVm = 9 244 A I FSM = 60 000 A V TO = 0.780 V Applications r T = 0.031 m. Types.

5SDD 92Z0401. Housingless Welding Diode. I FAVm = 9 244 A I FSM = 60 000 A V TO = 0.780 V Applications r T = 0.031 m. Types. SDD 92Z41 Housingless Welding Diode Properties SDD 92Z41 Key Parameters High forward current capability V RRM = 4 V Low forward and reverse recovery losses I FAVm = 9 244 A I FSM = 6 A V TO =.78 V Applications

More information

Redline. Comfort functions. Surge Arresters. SurgeGuard. Functions. Applications. Standards. Features. Marking. plug-in

Redline. Comfort functions. Surge Arresters. SurgeGuard. Functions. Applications. Standards. Features. Marking. plug-in Surge rresters Surgeuard omfort functions unctions Protection of an electrical installation and all electrical and electronic devices connected to this installation against destructive surges. Such voltage

More information

EGSTON Standard E2xFxWx 12W

EGSTON Standard E2xFxWx 12W General description The family of switchmode power supplies offers an unmatched degree of flexibility and performance fulfilling even the most stringent requirements. Highly flexible electrical configuration

More information

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases. G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable

More information

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants Installation instructions Contents Key points of installation Before installation Installation Installation check

More information

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850

More information

Product Overview 2Pro AC Devices Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications

Product Overview 2Pro AC Devices Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications Product Overview Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications The 2Pro AC family of devices provide integrated overcurrent/overvoltage/ overtemperature

More information

How To Make A Power Meter Safe

How To Make A Power Meter Safe Safety and Reliability Jörg Jelen Safety and Reliability Dear valued customers and prospects, You now hold the latest Leutron catalogue in your hands which will provide you with an overview of our products

More information

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole) Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic

More information

Surge Protection for Photovoltaic Systems

Surge Protection for Photovoltaic Systems Surge Protection for Photovoltaic Systems 2 photovoltaic generator disconnection boxes Index Introduction 4 Protection of PV systems 5 Surge Protection Range for PV system 6 Surge Protection Panels for

More information

Transient and Lightning Protection for the Water Industries

Transient and Lightning Protection for the Water Industries Transient and Lightning Protection for the Water Industries Mike Nager Phoenix Contact [email protected] 5 th ISA Water/Wastewater Automatic Controls Division Symposium (WWAC) August 3-5, Orlando,

More information

Trip circuit supervision relay. Type RXTCS

Trip circuit supervision relay. Type RXTCS Trip circuit supervision relay Type RXTCS ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm

More information

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Surge Protection and Power Supply Units 2013 / 2014

Surge Protection and Power Supply Units 2013 / 2014 Surge Protection and Power Supply Units 2013 / 2014 6 PCB connection technology and electronics housing PCB terminal blocks and plug-in connectors Electronics housing Connection technology for field devices

More information

EMC Engineering Guidelines For Automation Systems PS 4 PS 416 04/97 AWB 27-1287-GB

EMC Engineering Guidelines For Automation Systems PS 4 PS 416 04/97 AWB 27-1287-GB EMC Engineering Guidelines For Automation Systems PS 4 PS 416 1st edition 04/97 Moeller GmbH, Bonn Author: Werner Albrecht Editors: Klaus Krüger, Thomas Kracht Translator: Chris Baker, Terence Osborn Contents

More information

System pro M compact Miniature Circuit Breaker S 200/S 200 M

System pro M compact Miniature Circuit Breaker S 200/S 200 M Data Sheet System pro M compact Miniature Circuit Breaker S 200/S 200 M 2CDC021023S0012 2CDC021038S0012 The miniature circuit breakers of the System pro M compact series S 200 and S 200 M provide state-of-the-art

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201 Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

Current distribution Comb busbars for Declic and SFT residential devices

Current distribution Comb busbars for Declic and SFT residential devices Current distribution Comb busbars for Declic and SFT residential devices Comb busbar, for connecting 26 x 9 mm modules, consisting of two insulated bars to supply 1P + N devices (Declic, SFT, etc.). Due

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Safety Relays ESM/ESM-F

Safety Relays ESM/ESM-F Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

This is a preview - click here to buy the full publication TECHNICAL REPORT

This is a preview - click here to buy the full publication TECHNICAL REPORT TECHNICAL REPORT IEC TR 62066 First edition 2002-06 Surge overvoltages and surge protection in low-voltage a.c. power systems General basic information Surtensions de choc et protection contre la foudre

More information

New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance

New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance Dennis W. Lenk, Fellow, IEEE Abstract-- This paper examines performance

More information

High-Voltage Circuit-Breakers 3AP1/2 72.5 kv up to 550 kv. Power Transmission and Distribution

High-Voltage Circuit-Breakers 3AP1/2 72.5 kv up to 550 kv. Power Transmission and Distribution High-Voltage Circuit-Breakers AP/ 7.5 kv up to 550 kv Power Transmission and Distribution The AP/ High-Voltage Circuit-Breakers Now Applicable for 550 kv Decades of our experience in high-voltage switching

More information

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c 91052 Erlangen Germany. www.siemens.

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c 91052 Erlangen Germany. www.siemens. Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c 91052 Erlangen Germany www.siemens.com/energy For questions on power transmission and distribution, please contact

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60071-2 Third edition 1996-12 Insulation co-ordination Part 2: Application guide This English-language version is derived from the original bilingual publication by leaving out

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

Surge Protection Main Catalogue 2014/ 2015. New Products. www.dehn-international.com

Surge Protection Main Catalogue 2014/ 2015. New Products. www.dehn-international.com Surge Protection Main Catalogue 2014/ 2015 New Products www.dehn-international.com DEHNcombo YPV SCI (FM) Combined lightning current and surge arrester type 1 + type 2 for use in photovoltaic generator

More information

Contact expander modules

Contact expander modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:

More information

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D-85366 MOOSBURG TEL. +49 87 61 6 81-0 FAX +49 87 61 68 12 30

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D-85366 MOOSBURG TEL. +49 87 61 6 81-0 FAX +49 87 61 68 12 30 40 DRIESCHER - Low voltage fusedswitch-disconnector system 40 Rated current upto 445 A 40 84 40 40 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D-8566 MOOSBURG TEL. +49 87 6 6 8-0 FAX +49 87 6

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear. ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear. EN Edition: 6 from 10.03.2014 Supercedes the edition: 5 from 16.09.2013 Features: uninterrupted supply of 13,8VDC/1A supply voltage: external

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

White paper. ABB solutions for switching and protection of low speed wind turbines

White paper. ABB solutions for switching and protection of low speed wind turbines White paper ABB solutions for switching and protection of low speed wind turbines ABB solutions for switching and protection of low speed wind turbines Index 1 Introduction...2 2 Full converter configuration...4

More information

Installation and operating instructions

Installation and operating instructions English Installation and operating instructions Energy meter 3-phase CETS-A via up to 1500A Description The CETS-A is a compact electronic active power energy meter for application in 3-phase power lines

More information

instabus KNX / EIB System System E F G H

instabus KNX / EIB System System E F G H Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA

More information

Arc Terminator Active Arc-Resistant Switchgear

Arc Terminator Active Arc-Resistant Switchgear Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

Silvertel. Ag5200. 1 Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Silvertel. Ag5200. 1 Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power Silvertel V1.1 November 2012 Datasheet Pb 1 Features IEEE802.3at and IEEE802.3af compliant Maximum 30W output power Dual In-Line (DIL) package size 50.6mm (L) x 30mm (W) Overload, short-circuit and thermal

More information

e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN

e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN We create ideas with power! ELEKTROMETAL ENERGETYKA SA is a new Polish company providing solutions for electrical power engineering. Our services

More information

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power App Notes ~ Outdoor Power System Design and Cost Considerations 1 Authors Peter Nystrom President TSi Power Corp. Coordination of Telecommunications Surge Protective Devices in Countries with Unstable

More information

Protection from Short-circuit

Protection from Short-circuit Protection from Short-circuit Back-up Fuse-Link with ÜLA (controlled power dissipation) Test device for tripping device Special version with threat High-voltage Fuse-Link for voltage transformers (HSW)

More information

AN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x

AN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x On January 1, 1996, exports into Europe began facing some tough transient immunity standards. The International Electrotechnical Commission (IEC), a worldwide

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Gas Discharge Tubes GTCX36-XXXM-R05 Series

Gas Discharge Tubes GTCX36-XXXM-R05 Series GTCX36-XXXM-R05 Series TE Circuit Protection 6mm 3Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data

More information