Measuring the Point Spread Function of a Fluorescence Microscope

Similar documents
CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

THE COMPOUND MICROSCOPE

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

EXPERIMENT #1: MICROSCOPY

Acoustic GHz-Microscopy: Potential, Challenges and Applications

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

Endoscope Optics. Chapter Introduction

Convex Mirrors. Ray Diagram for Convex Mirror

Bio 321 Lightmicroscopy Electronmicrosopy Image Processing

EXPERIMENT 6 OPTICS: FOCAL LENGTH OF A LENS

waves rays Consider rays of light from an object being reflected by a plane mirror (the rays are diverging): mirror object

Applications of confocal fluorescence microscopy in biological sciences

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

Principles of Microscopy and Confocal and Fluorescence Microscopy

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Physics 441/2: Transmission Electron Microscope

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

RAY OPTICS II 7.1 INTRODUCTION

Rutgers Analytical Physics 750:228, Spring 2016 ( RUPHY228S16 )

Basic Optics System OS-8515C

Forensic Science: The Basics. Microscopy

Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, , 1 April 1998)

Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012

Solution Derivations for Capa #14

Laser tweezer controlled solid immersion lens for high resolution imaging in microfluidic and biological samples

Geometric Optics Converging Lenses and Mirrors Physics Lab IV

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

Fluorescence Microscopy for an NMR- Biosensor Project

Optical Systems Design with Zemax OpticStudio. Lecture 1

Introduction to microstructure

Light and its effects

Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments

MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

Care and Use of the Compound Microscope

Near-field scanning optical microscopy (SNOM)

Crystal Optics of Visible Light

One example: Michelson interferometer

LIGHT SECTION 6-REFRACTION-BENDING LIGHT From Hands on Science by Linda Poore, 2003.

GLOBAL COLLEGE OF ENGINEERING &TECHNOLOGY: YSR DIST. Unit VII Fiber Optics Engineering Physics

Diffraction of Laser Light

Procedure: Geometrical Optics. Theory Refer to your Lab Manual, pages Equipment Needed

Biomedical & X-ray Physics Kjell Carlsson. Light Microscopy. Compendium compiled for course SK2500, Physics of Biomedical Microscopy.

Untangling the megapixel lens myth! Which is the best lens to buy? And how to make that decision!

Review for Test 3. Polarized light. Action of a Polarizer. Polarized light. Light Intensity after a Polarizer. Review for Test 3.

Single Photon Counting Module COUNT -Series

Chapter 17: Light and Image Formation

View of ΣIGMA TM (Ref. 1)

Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer...

LIGHT REFLECTION AND REFRACTION

Lenses and Apertures of A TEM

1. You stand two feet away from a plane mirror. How far is it from you to your image? a. 2.0 ft c. 4.0 ft b. 3.0 ft d. 5.0 ft

1 of 9 2/9/2010 3:38 PM

Z-Stacking and Z-Projection using a Scaffold-based 3D Cell Culture Model

Immersion Oil and the Microscope

BACTERIAL ENUMERATION

Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red

MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY

Physics 116. Nov 4, Session 22 Review: ray optics. R. J. Wilkes

Experiment 3 Lenses and Images

A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31

PROTOCOL. Immunocytochemistry (ICC) MATERIALS AND EQUIPMENT REQUIRED

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy

Optical Communications

9/16 Optics 1 /11 GEOMETRIC OPTICS

Microscope Lab Introduction to the Microscope Lab Activity

Refractive Index Measurement Principle

Chapter 1 High-Resolution Optical and Confocal Microscopy

Size Of the Image Nature Of the Image At Infinity At the Focus Highly Diminished, Point Real and Inverted

MICROSCOPY MARKETING GUIDE

Overview Image Acquisition of Microscopic Slides via Web Camera

Study Guide for Exam on Light

Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012

Refraction of Light at a Plane Surface. Object: To study the refraction of light from water into air, at a plane surface.

A new high-aperture glycerol immersion objective lens and its

Fiber Optics: Fiber Basics

Product Range Overview

Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications

PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES

Optics I: lenses and apertures

What are Fibre Optics?

Lesson 29: Lenses. Double Concave. Double Convex. Planoconcave. Planoconvex. Convex meniscus. Concave meniscus

Looking through the fish-eye the Electron Ronchigram. Duncan T.L. Alexander CIME seminar May 24, 2012

Lenses and Telescopes

Chapter 27 Optical Instruments The Human Eye and the Camera 27.2 Lenses in Combination and Corrective Optics 27.3 The Magnifying Glass

Diffraction of a Circular Aperture

Advances in scmos Camera Technology Benefit Bio Research

C) D) As object AB is moved from its present position toward the left, the size of the image produced A) decreases B) increases C) remains the same

Overview of Optical Recording Technology- Current Status and Near Term Projections

Optical laser beam scanner lens relay system

Optical Microscopy Beyond the Diffraction Limit: Imaging Guided and Propagating Fields

NAME THE POLARIZING LIGHT MICROSCOPE AND FORENSIC SCIENCE. I. Introduction

Thin Lenses Drawing Ray Diagrams

Software-based three dimensional reconstructions and enhancements of focal depth in microphotographic images

Transcription:

Frederick National Laboratory Measuring the Point Spread Function of a Fluorescence Microscope Stephen J Lockett, PhD Principal Scientist, Optical Microscopy and Analysis Laboratory Frederick National Laboratory National Cancer Institute

Contents Basics of image formation Why resolution is not perfect Theoretical spatial resolution limit Air versus immersion objective lenses Why it is important to measure Point Spread Function (PSF) How to measure PSF Examples of PSF measurements; why 3D is important Spherical aberration Objective Lenses and the Correction collar Confocal Fluorescence Microscopy

Basics of Image Formation depth 2D microscope image v 2 3D microscope image v 1 u 1 u 2 f Magnification, M = v u

Why resolution is not perfect: Wave Properties of Light Interference + = Constructive + = Destructive

Spatial Resolution in Optical Microscopy

The Optical Resolution Limit Spatial resolution, x = λ l d (Ernst Abbe, 1874) Numerical aperture, NA λ d 2l d and spatial resolution, x x = λ 2NN l

Theoretical Spatial Resolution Limit For conventional, fluorescence microscopy: λ em = 525 nm, NA = 1.4, n = 1.515 Lateral resolution = 0.51 λ ee NN Depth resolution = 1.67 n λ ee NN 2 = 191 nm = 678 nm

Air Vs Immersion Objective Lenses objective For air, θ max = 41 o cover glass θ n air = 1.0, n oil = 1.515 Image brightness = NA M 2

Why it is important to measure PSF 1) Know what level of detail to expect from the image. 2) Facilitates comparison of results acquired across different instruments. 3) Check that the microscope is performing optimally. The PSF checks the entire emission light path, not just the objective lens. 4) Know when it is better to use an oil or water objective lens. 5) Know when the correction collar is optimized. 6) Post-processing such as deconvolution require an accurate assessment of the PSF.

How to measure PSF 1) Prepare a sample of 0.1 µm diameter fluorescent beads dried onto a #1.5 coverslip (170 µm thick). Invert the coverslip onto a drop of high refractive index mounting medium (e.g. 15 µl of ProLong Gold for a 22 X 22 mm coverslip). Allow medium to cure. If the medium does not cure, then seal coverslip edges to the slide with nail enamel. 2) Instead of (1), pre-mounted bead slide can be purchased from Life Technologies (cat # T14792). 3) Clean the objective lens and bead slide. Ensure that the microscope is warmed up and stable. 4) Acquire a z stack of images with a depth spacing of at least one fifth of the expected axial resolution (for example a spacing of 120 nm for an oil, 1.4 NA lens). Also, ensure that the pixel size in the x / y directions is at least half the expected lateral resolution (for example 100 nm for an oil, 1.4 NA lens). 5) Generate an intensity profile in the z direction through the center of the bead and measure the full width half maximum (FWHM) of the profile. This is the axial resolution.

Examples of PSFs Y X Y Z Z X Intensity 100X, 1.49 NA Nikon lens, oil Depth Z X 10X, 0.3 NA Nikon lens, dry

Example of a Bad PSF Y X 100X, 1.3 NA lens, oil Z X

Spherical Aberration, Refractive Index Mismatch cell sample water y If n 1 = n 2 then all light rays from the lens will focus at a single point a distance y into the sample. n 1 (> n 2 ) oil n 2 θ 1 θ 2 x h When n 1 > n 2, the rays will bend downwards. Using Snell s law: sin θ 1 sin θ 2 = n 2 n 1 h 2 = ( n 2 n 1 ) 2 (x 2 + y 2 ) x 2 h is a function of x, Therefore rays crossing the interface from the oil to the cell at different distances (x) from the center will not focus at the same depth (h) in the cell. PreCongress Course

Using the Correct Immersion Media To avoid refractive index mismatch and the resulting spherical aberration, choose the right type of immersion objective. (Courtesy of ZOYC Live Cell Imaging Workshops 2010) PreCongress Course

Using the Correction Immersion Media Using water immersion objectives for samples in liquid media captures more signal and preserves resolution better than refractive index mismatched oil immersion objectives. oil immersion objective water immersion objective NA=1.4 NA=1.2 (Courtesy of ZOYC Live Cell Imaging Workshops 2010) PreCongress Course

Examples of Objective Lens PlanApo N model 60X magnification 1.40 Numerical aperture Oil Immersion media SC Super corrected Infinity corrected 0.17 Cover Glass thickness FN22 Field of view (0.22 mm) XL Plan N model 25X magnification 1.05 Numerical aperture W Water media MP Multi photon Infinity corrected 0 0.23 Adjustable cover glass thickness FN18 Field of view (0.18 mm) PreCongress Course

Correct and Incorrect Correction Collar 100X, 1.49 lens, good collar 100X, 1.49 lens, bad collar PreCongress Course

PSF Equations for Confocal Microscopy For confocal fluorescence microscopy: Lateral resolution = 0.37 λ NA Axial resolution = 0.64 λ n n2 NA2, where λ = λexλem 2 λ 2 ex+λ 2 em PreCongress Course

Summary Understand conceptually why the spatial resolution of an optical microscope is not perfect. Merits of immersion lenses over dry lenses. Covered the basics of the procedure to measure the PSF. Recognize a good versus bad PSF Know the role of the correction collar. PreCongress Course