Siebert DisplayManager

Similar documents
OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC.

Podium View TM 2.0 Visual Presenter Image Software User Manual - English (WINDOWS)

Remote Access Server - Dial-Out User s Guide

Keep it Simple Timing

Installing the Gerber P2C Plotter USB Driver

Network FAX Driver. Operation Guide

Network Installation Guide. WorkForce 610 Series Artisan 710 Series

Instruction manual. testo easyheat Configuration and Analysis software

FrontDesk Installation And Configuration

Network Installation Guide. Artisan 810 Series

How To Download From A Tachograph With A Tachoreader Combo (Tachograph)

Figure 1: RotemNet Main Screen

RMCS Installation Guide

SHARP Digital Signage Software Pro PN-SS05 OPERATION MANUAL

Vicon Flash Upgrade Software

Palomar College Dial-up Remote Access

Contents. Hardware Configuration Uninstalling Shortcuts Black...29

PTPhoneManager II. User guide

EPM110 Field Strength Measuring Instrument

NDA ISSUE 1 STOCK # CallCenterWorX-Enterprise IMX MAT Quick Reference Guide MAY, NEC America, Inc.

Addendum Advanced POS Printer Drivers

Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.

Device Installer User Guide

Getting Started with IntelleView POS Administrator Software

Monitoring Network DMN

HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

NETWORK PRINT MONITOR User Guide

Iridium Extreme TM Satellite Phone. Data Services Manual

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Guide to Installing BBL Crystal MIND on Windows 7

LockView CompX Database & Network Configuration & Installation Manual

TECHNICAL BULLETIN. Configuring Wireless Settings in an i-stat 1 Wireless Analyzer

Model 288B Charge Plate Graphing Software Operators Guide

Sharp Remote Device Manager (SRDM) Server Software Setup Guide

EPSON Scan Server & EPSON TWAIN Pro Network

OfficeServ Link. User Guide. Version 2.1 June 2005

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

PC Program User s Guide ( ) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming

Handheld LPC Utility Software for Windows. Operation Manual

User's Guide. Using RFDBManager. For 433 MHz / 2.4 GHz RF. Version

ActiView. Visual Presenter Image Software User Manual - English

QIAsymphony Management Console User Manual

VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0

Andover Continuum Remote Communication Configuration Guide

Sign Compatibility. Tru ColorXP

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

MULTIFUNCTIONAL DIGITAL SYSTEMS. Network Fax Guide

Metasys System Direct Connection and Dial-Up Connection Application Note

SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

64-Bit Compatibility with Micromeritics Applications

Vicon Flash Upgrade Software

To Begin Customize Office

Korosi Monitoring System (KMS) Software Manual

Global Monitoring + Support

I. DigitalCAT Captioning Software Overview A. Welcome B. Acquiring the Captioning Add-On C. Purpose of this Guide...

FLoader User's Manual

3M Occupational Health and Environmental Safety 3M E-A-Rfit Validation System. Version 4.2 Software Installation Guide (Upgrade) 1 P age

Ultra Thin Client TC-401 TC-402. Users s Guide

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

footscan SCSI system Installation guide: balance software

TICO-EN. TiXML-Console TICO. User Manual V

PIGCHAMP MOBILE. PigCHAMP Knowledge Software. Installation Guide for Mobile Units

ABUS WIRELESS ALARM SYSTEM

MultiOne. Getting started

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

Diamond II v2.3 Service Pack 4 Installation Manual

Exeba -ATS. User Guide. Escan Technologies Corporation

Legal Notes. Regarding Trademarks KYOCERA MITA Corporation

OPTAC Fleet Viewer. Instruction Manual

LockView 4.2 CompX Database & Network Configuration & Installation Manual

User Manual Network Interface

Manuals for This Product

First Installation Guide

Sartorius

Global Water Instrumentation, Inc.

AB-Clock. Manual. Copyright by GRAHL software design

IP SERIAL DEVICE SERVER

Legal Notes. Regarding Trademarks KYOCERA Document Solutions Inc.

Create a PDF File. Tip. In this lesson, you will learn how to:

INSTALLING MICROSOFT SQL SERVER AND CONFIGURING REPORTING SERVICES

Maintaining the Content Server

User s Guide for version 5 Page

IPRS-7 IP/GPRS PC Receiver Software Quick Start V1.2

Legal Notes. Regarding Trademarks. Models supported by the KX printer driver KYOCERA MITA Corporation

User Guide HUAWEI UML397. Welcome to HUAWEI

MULTIFUNCTIONAL DIGITAL SYSTEMS. Operator's Manual for TWAIN Driver/File Downloader

Basics. a. Click the arrow to the right of the Options button, and then click Bcc.

1 Minimum system requirements

Backup Assistant. User Guide. NEC NEC Unified Solutions, Inc. March 2008 NDA-30282, Revision 6

Driver Installation and Hyperterminal Operation of iload Digital USB Sensors

KX Driver User Guide

Manual Client Management Software HDR50-CMS

Central Management System

Using Avaya Flare Experience for Windows

Transcription:

Pos: 2 /Siebert/Bedienungsanl eitungen/siebert Display Manager/Titelseite @ 1\mod_1357809374670_48.docx @ 5398 @ @ 1 Pos: 3 /Siebert/Seitenumbruch @ 0\mod_1314194553878_0.docx @ 150 @ @ 1 Siebert DisplayManager Operating instructions

Pos: 5 /Siebert/Seitenumbruch @ 0\mod_1314194553878_0.docx @ 150 @ @ 1 Pos: 4 /Siebert/Bedienungsanl eitungen/gerätebeschr eibung Grossanzeigen all e Serien/Kontakt @ 1\mod_1339668951540_48.docx @ 4323 @ 1 @ 1 1 Contact www.siebert-group.com GERMANY Siebert Industrieelektronik GmbH Siebertstrasse, D-66571 Eppelborn P.O. Box 11 30, D-66565 Eppelborn Phone +49 (0)6806 980-0, Fax +49 (0)6806 980-999 email info.de@siebert-group.com AUSTRIA Siebert Österreich GmbH Mooslackengasse 17. A-1190 Wien Phone +43 (0)1 890 63 86-0, Fax +43 (0)14 890 63 86-99 email info.at@siebert-group.com FRANCE Siebert France Sarl 33 rue Poincaré, F-57200 Sarreguemines P.O. Box 90 334, F-57203 Sarreguemines Cédex Phone +33 (0)3 87 98 63 68, Fax +33 (0)3 87 98 63 94 email info.fr@siebert-group.com THE NETHERLANDS Siebert Nederland B.V. Jadedreef 26, NL-7828 BH Emmen Phone +31 (0)591-633444, Fax +31 (0)591-633125 email info.nl@siebert-group.com SWITZERALND Siebert AG Bützbergstrasse 2, P.O. Box 91, CH-4912 Aarwangen Phone +41 (0)62 922 18 70, Fax +41 (0)62 922 33 37 email info.ch@siebert-group.com BAL DisplayManager 5.01 2/18

Pos: 7 /Siebert/Seitenumbruch @ 0\mod_1314194553878_0.docx @ 150 @ @ 1 Pos: 6 /Siebert/Bedienungsanl eitungen/gerätebeschr eibung Grossanzeigen all e Serien/R echtlicher Hi nweis @ 1\mod_1339668878995_48.docx @ 4317 @ 1 @ 1 2 Legal note Siebert Industrieelektronik GmbH This operation manual has been prepared with the utmost care. However, we do not accept any liability for possible errors. We always appreciate your suggestions for improvement, corrections, comments and proposals. Please contact us: editing@siebert-group.com Siebert, LRD and XC-Board are registered trademarks of Siebert Industrieelektronik GmbH. All other product names mentioned herein may be trademarks or registered trademarks of their respective owners. We reserve the right to make alterations to the technical data and delivery options without notice. - All rights reserved, including the rights of translation. No part of this document may in any form or by any means (print, photocopy, microfilm or any other process) be reproduced or by using electronic systems be processed, copied or distributed without our written permission. BAL DisplayManager 5.01 3/18

Pos: 8 /Siebert/Bedienungsanl eitungen/m odul Inhaltsverzeichnis @ 1\mod_1352981287156_48.docx @ 5155 @ @ 1 Table of contents 1 Contact 2 2 Legal note 3 3 Software description 6 Model designation... 6 Properties... 6 PC requirements... 6 Installation... 6 4 First steps 7 Program start... 7 Defining the display... 7 Entering texts... 7 Send text... 7 5 Creating and managing displays 8 Display files... 8 Display window... 8 Adding displays... 8 Opening displays... 8 Opening display automatically after program start... 8 Closing the display... 9 Deleting a display... 9 Defining groups... 9 Grouping displays... 9 6 Parameterizing displays 11 Paging interval... 11 Brightness... 11 Device address... 11 Serial interface... 11 TCP/IP connection... 11 Modem connection... 11 Text mode... 12 User-defined character sets... 12 Automatic brightness control... 12 7 Creating and managing texts 13 Entering texts... 13 Inserting macros... 13 Font type... 13 Font color... 13 BAL DisplayManager 5.01 4/18

Pos: 9 /Siebert/Seitenumbruch @ 0\mod_1314194553878_0.docx @ 150 @ @ 1 Flashing... 13 Marquee... 14 Paging... 14 Deleting formatting... 14 Static texts... 14 Saving texts... 15 Opening texts... 15 Deleting texts... 15 8 Showing text on the large size display 16 Establish connection... 16 Sending text to the display... 16 Call static text... 16 Current Content... 16 Restoring static text... 16 Timer... 16 9 Menu bar 18 BAL DisplayManager 5.01 5/18

Pos: 15 /Si ebert/seitenumbr uch @ 0\mod_1314194553878_0.docx @ 150 @ @ 1 Pos: 10 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/softwar e-beschr eibung/übs Softwar e-beschrei bung @ 1\mod_1357811416374_48.docx @ 5460 @ 1 @ 1 3 Software description Pos: 11 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/softwar e-beschr eibung/geltungsber eich @ 1\mod_1357811396610_48.docx @ 5448 @ 2 @ 1 Model designation This operating manual applies for the software Siebert DisplayManager. Pos: 12 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/softwar e-beschr eibung/eigenschaften @ 1\mod_1357811336859_48.docx @ 5430 @ 2 @ 1 Properties Pos: 13 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/softwar e-beschr eibung/pc Anforderungen @ 1\mod_1357811404455_48.docx @ 5454 @ 2 @ 1 PC requirements The software Siebert DisplayManager is an editor for comfortable creation and management of dynamic and static texts, which are displayed on the large displays of the series SX502. The texts to be displayed on the display can be entered directly and sent to the display. Alternatively, texts can be saved and called up manually or time-controlled, if necessary. The software Siebert DisplayManager can be used to activate several displays at the same time. Microsoft Windows XP, Windows 7 Processor from 1 GHz, from 1 GB RAM Screen resolution 800 x 600 or higher Serial interface or network card with TCP/IP Pos: 14 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/softwar e-beschr eibung/installati on @ 1\mod_1357811517992_48.docx @ 5472 @ 2 @ 1 Installation Introduce the CD-ROM into the CD-ROM drive and follow the instructions of the installation wizard. BAL DisplayManager 5.01 6/18

Pos: 21 /Si ebert/seitenumbr uch @ 0\mod_1314194553878_0.docx @ 150 @ @ 1 Pos: 16 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/erste Schritte/Ü BS Erste Schritte @ 1\mod_1357811864842_48.docx @ 5478 @ 1 @ 1 4 First steps Pos: 17 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/erste Schritte/Programmstart @ 1\mod_1357811899365_48.docx @ 5483 @ 2 @ 1 Program start Click on "Programs Siebert DisplayManager" in the Windows start menu to start the Siebert DisplayManager. Pos: 18 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/erste Schritte/Anzeige defini eren @ 1\mod_1357811965979_48.docx @ 5488 @ 2 @ 1 Defining the display Click on File in the menu bar and then click on New display. The dialog box Add a new display is opened. Enter the name of the display (e. g. Production 1) in the Name input field. Define the size of the display (e.g. 2 lines, 20 characters per line) in the input fields Number of lines and Characters per line. Define the color option of the display in the Color section and then click on the Next button. In the section Interface you specify the type of data transfer (Serial, TCP/IP, Modem, Grouping). The text mode defines the desired text type (Dynamic text or Static text). Then click Next. Serial Pos: 19 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/erste Schritte/T exte eing eben @ 1\mod_1357814887583_48.docx @ 5493 @ 2 @ 1 Entering texts Define the serial interface and the baud rate. Then click on Next. TCP/IP Define the IP address and the TCP port of the display. Then click Next. Modem Define the serial interface to which the modem is connected. In the input field number you enter the number of the modem integrated in the display. Then click Next. To change the memory place of display click Select. Then you can save the newly created display by clicking Next. After you have defined and saved the settings for your display a window opens automatically in which you can edit the display texts. Pos: 20 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/erste Schritte/T ext senden @ 1\mod_1357815206868_48.docx @ 5498 @ 2 @ 1 Send text Click on the first line in the input field and enter your text. Carry out the desired formatting by means of the commands in the Format menu. If no connection exists to the display click on Display in the menu bar and then click Connect. To send your text to the display click Display in the menu bar and the click Send. If you have chosen Static Text as text type click on Display in the menu bar and then click Call Static Text. BAL DisplayManager 5.01 7/18

Pos: 22 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeigen anleg en und verwalten/übs Anzeigen anlegen und ver walten @ 1\mod_1357816703461_48.docx @ 5510 @ 1 @ 1 5 Creating and managing displays Pos: 23 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeigen anleg en und verwalten/anzeigedatei en @ 1\mod_1357816734704_48.docx @ 5515 @ 2 @ 1 Display files Pos: 24 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeigen anleg en und verwalten/anzeigenfenster @ 1\mod_1357816795184_48.docx @ 5520 @ 2 @ 1 Display window The software Siebert DisplayManager allows to activate several displays. For this purpose each display is saved in an individual file that can be opened, if necessary, in a separate window. In the display window you find the input field and the preview window. Pos: 25 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeigen anleg en und verwalten/anzeige hinzufügen @ 1\mod_1357818512741_48.docx @ 5525 @ 2 @ 1 Adding displays In the input field the display texts are created and edited before sending them to the display. In the display preview the texts are displayed in the same form in which they will appear on the display. Pos: 26 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeigen anleg en und verwalten/anzeigen öffnen @ 1\mod_1357818637747_48.docx @ 5530 @ 2 @ 1 Opening displays Click on File in the menu bar and then on New Display. Define your display as described in Chapter 4. Click on File in the menu bar and the on Open display. Click on the corresponding display file and then click the Open button. A display window for this display opens. Pos: 27 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeigen anleg en und verwalten/anzeigen automatisch öffnen nac h Programmstart @ 1\mod_1357818747276_48.docx @ 5535 @ 2 @ 1 Opening display automatically after program start To allow a display to open automatically after the program start it must be registered in the DisplayManager. In the menu bar click Tools and then click Registered Displays. All already registered displays are displayed. Click the Add button and choose the desired display file. BAL DisplayManager 5.01 8/18

The display is registered and its display window opens. To remove a display open the dialog box Registered displays and click Delete. The display is removed from the registration, i.e. the display window stays open, but does not open automatically after program start. Pos: 28 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeigen anleg en und verwalten/anzeige schli essen @ 1\mod_1357819347381_48.docx @ 5540 @ 2 @ 1 Closing the display Pos: 29 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeigen anleg en und verwalten/anzeige l öschen @ 1\mod_1357819903884_48.docx @ 5545 @ 2 @ 1 Deleting a display Pos: 30 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeigen anleg en und verwalten/gr uppi erungen defi nier en @ 1\mod_1357820185735_48.docx @ 5550 @ 2 @ 1 Defining groups To close the work window click Window in the menu bar and after click Close. Delete the corresponding file using the usual Windows functions in the Explorer. A group is a virtual display and receives a display window, just like a real display. All displays that are assigned to a group receive the same data. Click File in the menu bar and after click New display. Define your display as described in Chapter 2 and select Grouping in section Interface. Pos: 31 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeigen anleg en und verwalten/anzeigen gruppi eren @ 1\mod_1357820383093_48.docx @ 5555 @ 2 @ 1 Grouping displays To add a display to a group click Tools in the menu bar and after click Grouping. The window Groupings opens. Only those displays can be grouped that are in the text mode Dynamic Text. In the combo box Group select the group to which you want to add displays or from which you want to delete displays. The list Available displays shows all displays that are open at the moment which are in the text mode Dynamic Text and are not yet added to the selected group. BAL DisplayManager 5.01 9/18

Pos: 32 /Si ebert/seitenumbr uch @ 0\mod_1314194553878_0.docx @ 150 @ @ 1 To add a display to the group click on the corresponding display in the list Available displays and after click Add. The displays assigned to this group appear in the list Current displays. All available displays can be assigned to the group by clicking the Add all button. To remove a display from the group click the corresponding group in the list Current displays and then click Delete. You can remove all displays from the grouping by clicking the Delete all button. BAL DisplayManager 5.01 10/18

Pos: 33 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeige par ametrieren/ü BS Anzeige par ametrieren @ 1\mod_1357820998477_48.docx @ 5561 @ 1 @ 1 6 Parameterizing displays Pos: 34 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeige par ametrieren/einl eitungssatz @ 1\mod_1357821034501_48.docx @ 5566 @ @ 1 Click Tools and after click Properties in the menu bar. The dialog box Properties for the currently active displays opens. Pos: 35 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeige par ametrieren/blätterinter vall @ 1\mod_1357821113747_48.docx @ 5571 @ 2 @ 1 Paging interval If a text contains more characters than can be displayed on the display, it will be automatically displayed in paging mode. Select register Display and enter the time interval in the input field Paging interval with which the display thumbs through the display preview. The paging interval of the display preview may differ from the one of the display. As default, a paging interval of 5 seconds is set. Pos: 36 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeige par ametrieren/h elligkeit @ 1\mod_1357821553338_48.docx @ 5576 @ 2 @ 1 Brightness Pos: 37 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeige par ametrieren/ger äteadresse @ 1\mod_1357821691302_48.docx @ 5581 @ 2 @ 1 Device address Pos: 38 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeige par ametrieren/seri elle Schni ttstelle @ 1\mod_1357828811533_48.docx @ 5586 @ 2 @ 1 Serial interface The brightness of the display can be set to normal brightness (0) or reduced brightness (1). Select register Display and enter the corresponding value in the input filed Brightness. As default the brightness level 0 is set. Select register Communication and in box Device address click Advanced. The window Device address opens. Activate, resp. deactivate the device address. If you have activated the device address define the number of digits of the device address under Address digits and click OK. Enter the device address in the field Device address. Enter these settings as specified in the display hardware. For parameterization of the serial interface select register Communication and in box Interface select option Serial port. For this set the serial interface and the bit rate in the combo boxes Com-Port and Baud rate. Click the Advanced button for further settings. The window Com port settings opens. The entry data should only be performed by experienced users. In box Format you can set parity, data bits and stop bits of the serial interface. In box Handshake you can set the handshake method. Choose the option None if you do not wish to use a handshake method. To activate the hardware handshake select Option RTS/CTS. To activate the software handshake select option XOn/XOff. Pos: 39 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeige par ametrieren/tc P/TC P/IP-Verbi ndung @ 1\mod_1357830092212_48.docx @ 5591 @ 2 @ 1 TCP/IP connection Select register Communication and in box Interface select TCP/IP. Now you can configure the TCP/IP connection in the box Network. Enter the IP address of the display without leading zeros in the Address input field. Enter the TCP port of the display in the input field Port. To verify whether the indicated IP address can be reached click Test. A ping is executed on the specified IP address. Pos: 40 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeige par ametrieren/m odem-verbi ndung @ 1\mod_1357830986767_48.docx @ 5596 @ 2 @ 1 Modem connection Select register Communication and in box interface select Modem. Now you can configure the Modem connection in the box Modem. In the input field Call number enter the number of the Modem integrated in the display. In combo box Com-Port select the serial interface on which the Modem is connected to the PC. Click on register Advanced, for further settings. The window Modem Settings is opened. In input field Initializing you can enter additional AT commands which are transmitted to the Modem before each calling. For example, the AT command M0 causes that the internal speaker of the Modem is always off. In the input field Connection timeout you can specify the time interval in seconds, how long to wait for answer while dialing. BAL DisplayManager 5.01 11/18

Pos: 44 /Si ebert/seitenumbr uch @ 0\mod_1314194553878_0.docx @ 150 @ @ 1 Pos: 41 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeige par ametrieren/t extmodus @ 1\mod_1357832647827_48.docx @ 5601 @ 2 @ 1 Text mode In input field Auto disconnect you can specify the time interval in seconds how long to wait on hanging-up after sending the last data packet to the Modem. Depending on the number of bytes to be transmitted this value must be increased accordingly. This is especially to be considered during transmission of Static Texts to the display. For review in this case, the Statics texts should be read back again from the display after transmission. Click Display in the menu bar and after click Static text on/off to define if you want to create dynamic or static texts. Pos: 42 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeige par ametrieren/benutzerdefi nierte Z eichensätze @ 1\mod_1357833016010_48.docx @ 5606 @ 2 @ 1 User-defined character sets Click Tools in the menu bar and after click User-defined character sets. The window User-defined character sets opens. You now can set the character set by clicking the Browse button. The set character set is used for the display preview. The character sets (sxf-files) are set up with the tool FontManager. Character sets with a character height of 7 pixels can be set as user-defined character set1, character sets with a height of 14 or 16 pixels can be set as user-defined character set2. Please note that the newly set character sets have not been loaded into the display yet. With the tool FontManager you download the Character sets in the display. Click Display in the menu bar and after click Reading out character set. To download the user-defined character sets from the display. The transferred character sets are saved and automatically set in the dialog window User-defined character sets. Pos: 43 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/anzeige par ametrieren/automatische H elligkeitssteuer ung @ 1\mod_1357833677265_48.docx @ 5611 @ 2 @ 1 Automatic brightness control For two freely selectable times during a day, the brightness of the displays can be set automatically tot he selected brightness level. To configure the Automatic brightness control click Tools in the menu bar and after click Brightness control. The window Brightness control opens. Set the desired times and the corresponding brightness levels. Activate the timer and confirm your settings with OK. BAL DisplayManager 5.01 12/18

Pos: 45 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte erstell en und verwalten/übs T ext e erstellen und ver walten @ 1\mod_1357833896837_48.docx @ 5617 @ 1 @ 1 7 Creating and managing texts Pos: 46 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte erstell en und verwalten/t exte eingeben @ 1\mod_1357833944495_48.docx @ 5622 @ 2 @ 1 Entering texts Pos: 47 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte erstell en und verwalten/makr os ei nfügen @ 1\mod_1357834186391_48.docx @ 5627 @ 2 @ 1 Inserting macros Position the cursor in the input field and enter the desired text. The text is automatically displayed in the display preview, the current input position being highlighted by white flashing. The font size Acala 7 in the font color red is set as default. In the input field both, the entered test and the commands for text formatting and the commands for macro features are shown. The entered text is always shown in the color black in the input field. Commands for text formatting are shown in blue, commands for macro features are shown in light blue. Entering and formatting texts in the input field does not yet have an effect on the display. Macros are available for the following functions: current time current hour value current minute value current second value current date current day current month current year current weekday variable bar graph Pos: 48 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte erstell en und verwalten/schriftart @ 1\mod_1357834348368_48.docx @ 5632 @ 2 @ 1 Font type Pos: 49 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte erstell en und verwalten/schriftfar be @ 1\mod_1357834420327_48.docx @ 5637 @ 2 @ 1 Font color To insert macros in the text, click on Macros in the menu bar and then on the corresponding macro. In the input field, the macros are shown as commands. The corresponding values are entered in the display preview. Four fixed and two user-defined character sets are available on the display. Mark a section of the text and click on Format in the menu bar. Then select the desired font. In the input field the font type is shown as the corresponding command. Only for multi-color displays Mark the characters in the input field, of which you would like to change the color. Click on Format in the menu bar and then select red, yellow or green. In the input field the font color is shown as the corresponding command. Pos: 50 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte erstell en und verwalten/bli nken @ 1\mod_1357834587784_48.docx @ 5642 @ 2 @ 1 Flashing In the input field mark the characters that you want to display flashing. Click on Format in the menu bar and after click Flashing. The corresponding commands are entered in the input field. BAL DisplayManager 5.01 13/18

For deactivating the flashing characters mark the flashing characters in the input field and click again on the Flashing button. Pos: 51 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte erstell en und verwalten/laufschrift @ 1\mod_1357834705113_48.docx @ 5647 @ 2 @ 1 Marquee To activate the marquee position the curser at the position from which you want the marquee to start. Click on Format and after click on Marquee. The corresponding command is entered in the input field. To deactivate the marquee click on the line in the input field that contains the marquee. Now click the Marquee button again. Pos: 52 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte erstell en und verwalten/bl ätter n @ 1\mod_1357893667531_48.docx @ 5657 @ 2 @ 1 Paging If a text contains more characters than can be displayed in the entire display, it will be automatically displayed in paging mode. Enter a text in the input field or activate a saved text. To activate the paging function, click on Display in the menu bar and then click on Paging. Paging is now simulated in the display preview. For deactivating the paging mode click on Display in the menu bar again and click on Paging again. Once the text is edited in the input field the paging mode is finished. Pos: 53 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte erstell en und verwalten/f ormati erungen löschen @ 1\mod_1357894474140_48.docx @ 5662 @ 2 @ 1 Deleting formatting Pos: 54 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte erstell en und verwalten/statische T exte @ 1\mod_1357894643426_48.docx @ 5667 @ 2 @ 1 Static texts Mark the lines for which you want to delete the formatting commands. Click on Format and after click on Delete formattings. If the display is in static text mode, the texts can be organized via the toolbar Static text. Click on View in the menu bar and after click on Toolbars to show the toolbar. A static text file consists of several texts. To add more texts to the end of a static text file, click on Static text in the menu bar and after click on End. Then click on Static text in the menu bar and then click on Next to create a new static text. Analogously static texts are added to the beginning of the static text file using the buttons opposite. To add a new text at any position in the static text file click on Static text in the menu bar and then click on Add. The desired text position can be specified in the window Add new text. To swap the position of the current text with another text in the static text file click on Static text in the menu bar and then click on Swap. For entering the desired text position the window Swap text opens. BAL DisplayManager 5.01 14/18

Pos: 58 /Si ebert/seitenumbr uch @ 0\mod_1314194553878_0.docx @ 150 @ @ 1 To move the current text to another position in the static text file click on Static text in the menu bar and then click on Move. The window Move text, in which you can enter the desired text position, opens. If the current text is moved forwards in the static text file, all text between the indicated and the current position are moved backwards. The current text is now located at the indicated position. Moving the current text backwards in the static text file has the following effect: The texts that are on the following positions until the indicated position are moved in front. The current text is now located at the indicated position. To select a determined text in the static text file, click on the corresponding text in the Text selection field. The text is shown in the display preview. Pos: 55 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte erstell en und verwalten/t exte speichern @ 1\mod_1357897539702_48.docx @ 5672 @ 2 @ 1 Saving texts Pos: 56 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte erstell en und verwalten/t exte öffnen @ 1\mod_1357897845277_48.docx @ 5677 @ 2 @ 1 Opening texts Pos: 57 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte erstell en und verwalten/t exte löschen @ 1\mod_1357898044546_48.docx @ 5682 @ 2 @ 1 Deleting texts To delete a text from the static text file select the corresponding text in the Text selection field. Click on Static text in the menu bar and then click Delete. Click File in the menu bar and then click New text. Enter your text in the input field. Click File in the menu bar and then click Save text. In the window Save file as, enter the file name and confirm the input with Save. If the display is in dynamic mode the display texts are saved in *.sdt format. In the static text mode the static text file is saved in *.sft format. Click File in the menu bar and then click Open text. Select the desired file in the dialog window Open and click the Open button. Depending on the text mode of the display a dynamic text or a static text can be opened. Now the saved text appears in the input field. To delete text files use the usual Windows delete functions in the explorer. BAL DisplayManager 5.01 15/18

Pos: 59 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte auf der Grossanzeige darstellen/ü BS Texte auf der Grossanzeig e darstellen @ 1\mod_1357900219722_48.docx @ 5688 @ 1 @ 1 8 Showing text on the large size display Pos: 60 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte auf der Grossanzeige darstellen/ver bindung herstell en @ 1\mod_1357900264908_48.docx @ 5693 @ 2 @ 1 Establish connection To send the texts to the display a connection to the display has to be established. Click Display in the menu bar and then click Connect. Pos: 61 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte auf der Grossanzeige darstellen/t ext zur Anzeige senden @ 1\mod_1357900372310_48.docx @ 5698 @ 2 @ 1 Sending text to the display Pos: 62 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte auf der Grossanzeige darstellen/statischen Text aufrufen @ 1\mod_1357900570908_48.docx @ 5703 @ 2 @ 1 Call static text Pos: 63 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte auf der Grossanzeige darstellen/aktueller Inhalt @ 1\mod_1357900669334_48.docx @ 5708 @ 2 @ 1 Current Content Click Display in the menu bar and then click Send to show the text on the display. In the dynamic text mode the text is shown directly on the display. In the static text mode the generated static text file is transferred to the display. Afterwards you can call the desired static text. Select the corresponding text in the text selection field. Click Display in the menu bar and then click Static text. The selected text is shown in the display. The display preview always shows the text which is currently edited. The dynamic text sent last to the display can be restored in the display preview. Click Display in the menu bar and after click Dynamic text. Pos: 64 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte auf der Grossanzeige darstellen/statische T exte zurückl esen @ 1\mod_1357900866149_48.docx @ 5713 @ 2 @ 1 Restoring static text Click Display in the menu bar and then click Reading out static text. The static text file is transferred from display und the first text is shown in the display preview. Pos: 65 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/texte auf der Grossanzeige darstellen/ti mer @ 1\mod_1357900969374_48.docx @ 5718 @ 2 @ 1 Timer With the help of the timer you can determine at which point of time (date and time) a saved text is to show on the display. The timer function is for dynamic texts only. A connection to the display has to be established. Click Tools in the menu bar and then click Timer. The window Timer opens. In section Dynamic text select the text for which you want to define an automatic text call. In section Time define time and day for the automatic text call. If you want to define an exact date first click on the Date tab and then click on the selection arrow belonging to this section. Choose the desired date in the calendar. It is also possible to display texts automatically on a daily basis or on a certain day of the week. In this case click on one of the options. BAL DisplayManager 5.01 16/18

Pos: 66 /Si ebert/seitenumbr uch @ 0\mod_1314194553878_0.docx @ 150 @ @ 1 In section Display select the display on which the text is to show automatically. Adjust the brightness of the display for the text call. Click Apply to save your settings for the automatic text call. All text files are listed together with the corresponding settings for the automatic text calls in the date list. If you want to delete a fixed date, click on it in the date list and remove it by clicking Delete. BAL DisplayManager 5.01 17/18

=== Ende der Liste für T extmar ke Inhalt1 === Pos: 67 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/menül eiste/ü BS Menüleiste @ 1\mod_1357901334544_48.docx @ 5724 @ 1 @ 1 9 Menu bar Pos: 68 /Si ebert/bedi enungsanlei tungen/siebert Displ ay M anag er/menül eiste/inhal t M enüleiste @ 1\mod_1357901403559_48.docx @ 5729 @ @ 1 Alternatively the settings can also be made with the help of the menu bar. The symbols have the following meaning (from left to right): File New text, open text, save text, new display Edit Cut, copy, paste Display Connect, send, restore static text file, call static text Display Paging, static text on/off, current dynamic text Extras Properties, timer The symbols have the following meaning (from left to right): Format Color selection, selection of font from six different types, marquee, flashing, delete formatting BAL DisplayManager 5.01 18/18