FDA Building One. R. Andy Pahwa. Faculty Advisor: Jim Freihaut/Dustin Eplee

Similar documents
Occupancy: Assembly (A-3) and Business -Includes offices, seminar rooms, classrooms, and café facility. Duke University Medical School

Electrical Systems. <Presenter>

Product description NCC Data Center

Senior Thesis Final Report

GREEN SCHOOLS CASE STUDY. West Wing Elementary

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Mechanical Systems Proposal revised

Print Shop/Mail Room

Proof of Concept - Solar Energy DG Distribution Warehouse

GREEN DATA CENTER DESIGN

Integrated Solar Radiant Systems

EnergyPro Building Energy Analysis. Assisted Living Building

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

A Sustainable, Master-Planned Data Center Park.

AT&T Internet Data Center Site Specification Chicago Area (Lisle, IL)

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G

Strategic Data Centre Site Profiles. Data Centre Co-Location London East

Case Study -Sandy Grove Middle School First Net Positive Energy P3 School In North Carolina

Sustainable Strategies for Rehabilitation Projects: 9th Street Office Building Adaptive Reuse Case Study

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Deep Energy Savings in Existing Buildings

ALL STAR ELECTRIC COMPANY 10,000 Trumbull SE, Suite #F Albuquerque, NM (505) voice & fax NM License

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

Xcel Business Customers: Program and Rebate Summary

Siemens Gebze Location FIRST GREEN BUILDING IN TURKEY CERTIFICIED AS LEED GOLD

LEED Breadth. Introduction

LEED PRESENTATION OUTLINE

AT&T Internet Data Center Site Specification - Phoenix Area (Mesa, AZ)

Rules of Thumb Energy Efficiency in Buildings

AT&T Internet Data Center Site Specification San Diego Koll (San Diego, CA)

NEW JERSEY CENTER OF EXCELLENCE

Sustainable Design and Energy-Efficient Building Techniques for Existing Housing

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

Nominal Life Expectancy for Building Components

Center for Energy Education Laboratory

MECHANICAL PROJECT PROPOSAL

Topics for Today. Order of Magnitude Mechanical Estimating. Order of Magnitude Estimate Goal. Project Delivery Methods. Questions for Client

MURCH ELEMENTARY SCHOOL

Veterans Memorial Coliseum Options Study Appendix A - Deconstruction Scope of Work and Cost Estimate August 31, 2015

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings

NORTHERN VIRGINIA ONE (NoVa) DATA CENTER OVERVIEW

Mechanical, Plumbing, and Fire Protection Conditions

N O W A V A I L A B L E

Brian T. Patterson - Chairman. Governing Member, EMerge Alliance General Manager, Armstrong World Industries

Energy Efficient High-tech Buildings

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

GREEN BEYOND THE MYTH: ENERGY EFFICIENCY IN GREEN BUILDINGS

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME

Portable Energy Efficient Data Centre Solution

Vectren Commercial/Industrial New Construction Incentive Application

Energy'Saving,'Thermal'Comfort'and'Solar'Power'Information'Sheet'

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Iron Hill Corporate Center Newark, DE

OFFICE SPACE FOR LEASE THE WEST MALL TORONTO, ON

Geothermal Heat Pumps: A Pathway to Zero Net Energy (ZNE) for Schools, Homes and Businesses

Heating & Cooling Efficiency

GUIDELINES FOR PLAN CHECK AND PERMIT REQUIREMENTS FOR SOLAR ENERGY SYSTEMS

World s Greenest High Performance Data Center

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

LogisticsCentre IV Distribution Center

HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

FIRE-FIGHTING DESIGN BRIEF REPORT

Deep Energy Savings in Existing Buildings

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

Challenges and Failures in Green Building Design Using Under-Floor Air Distribution. Ken Urbanek, PE, HBDP, LEED AP Director of Engineering

Energy Strategic Plan Los Angeles Community College District Community College League Conference

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

Raising the Bar: A Comparison Study of Iowa s Current and Proposed Energy Code

BPC Green Builders. Green building for new and existing homes. Health Comfort Energy

University of Maryland s Gossett Field House College Park, MD

European Code of Conduct for Data Centre. Presentation of the Awards 2016

2015 RACE TO ZERO STUDENT DESIGN COMPETITION

AT&T Internet Data Center Site Specification New York III (Secaucus, NJ)

Experience Matters...

ENHANCED LABORATORY HVAC SYSTEM

Green Data Centre Design

MEETING AGENDA. Project Administrator:

Florida Energy Efficiency Code For Building Construction

san francisco//usa data center specifications tel: fax: internet + intellectual property + intelligence

HVAC Systems: Overview

Energy Efficiency Analysis for a Multi-Story Commercial Office Building. (LG Multi V III Heat Recovery VRF System)

The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL

Author: Smruti Srinivasan. Supervisor: Anna Provoost (KIEN) Rob Barnhoorn (KIEN) Graduation Professor: Prof.Dr.ir.J.F.G.Cobben

BOMA BESt AND LEED EBOM COMPARISON

LogisticsCentre IV Distribution Center

Potential of Energy Efficiency and Renewable Energy Savings To Impact Florida s Projected Energy Use in 2014

Building Permit Application

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.

Roofing Retrofits: Focus on Sustainability

COMMODITIZING THE DATA CENTER MARKET

Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.

ELECTRICAL SCHEMATIC DESIGN BRIEF

The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted.

Building Condition Assessment Report

COMPARATIVE LIFE-CYCLE ANALYSIS OF ENERGY-EFFICIENCY MEASURES AT TVA S CHATTANOOGA OFFICE COMPLEX: PHASE II RESULTS & FINAL DESIGN

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

How To Plan Out An Array Of Solar Panels

Transcription:

FDA Building One R. Andy Pahwa Faculty Advisor: Jim Freihaut/Dustin Eplee

Project Background Building One

Project Background Originally the headquarters of the Naval Surface Warfare Center

Project Background Function Type: Size (GSF): Office Building 102,000 SF Number of Stories: 4 Stories above Grade + Penthouse Date of Construction: 9/25/2007 11/15/2008 Contract Amount: $36,444,302

Project Background Construction Overview: -Modernization -Portioned Security Pavilion, Atrium Connector Link, Existing Building, Façade Restoration, Site Modification -Excavations of Security Pavilion & Atrium Connector simultaneous with Structural Modifications Electrical Overview: -13.8 kv, 3-Phase Power -480/277V Dry Type Transformer -UPS for emergency Back-Up Structural Overview: -Spread Footings -New Boring for additions -Existing Structure Reinforced Security & Fire Protection Overview: -Card Access / ID Clearance -CCTV s -IR Motion Detectors -Video Intercom Stations -Wet Pipe Sprinkler -recessed pendant fixtures Lighting Overview: -Fluorescent T5 s and CFL s -Photocell Dimming, Occupancy Sensors -use of Day-lighting

Existing Mechanical Penthouse Outside AHU: -5300 CFM -100% OA -Energy Recovery Wheel Serves: Perimeter FCU s Some VV Boxes w/ ReHeat in Interior Areas AHU - 1: -19,000 CFM -30% OA Serves: Perimeter CV Boxes Dual Duct TU s in Conference Rooms VV Boxes w/ ReHeat in Core Zone AHU - 2: -7,350 CFM -Min OA by OAHU Serves: Security Pavilion, Kept at Constant Volume, No Associated return OAHU AHU-1 Security Pavilion AHU-2

Existing Mechanical Penthouse Computer Room AC-1: -5,250 CFM -Temp Set: 61 F Serves: Electrical Room Computer Room AC-2: -6,050 CFM -Temp Set: 55 F OAHU AHU-1 CRAC-3 Serves: Telecom Room Computer Room AC-3: -2,800 CFM -Temp Set: 55 F CRAC-3 CRAC-3 Serves: Security Pavilion LAN Rooms CRAC-1 CRAC-2 AHU-2

Existing Mechanical Total plant Efficiency: 70% Central Utility Plant: -20 MW CoGen -5.6 MW Dual Fuel Engine (Natural Gas & Diesel) -Three 4.5MW Natural Gas Turbines -Two 1130-ton Absorption Chillers -Two 1130-Ton & Three 1980-Ton Electric Chillers -Three 10MMBtu/Hr Hot water boilers Delivers: -13.8 KV 3-Phase Electricity -200F Hot water -39F Chilled Water

Existing Mechanical LEED Features: -Heavy reuse of Raw materials Core, Shell, Public Area finishes, Restoration of Original Brick & Limestone Exterior -Low VOC Materials -Operable, Insulated, Low-E Steel Windows, Integrated w/ HVAC System and Controls -High Solar reflective Index Roof -Native, Low water Plants -Shuttle Service Provided, dedicated Hybrid/Carpool parking 9 3 2 Sustainable Sites 14 Points 2 2 1 Water Efficiency 5 Points 12 1 2 Energy & Atmosphere 17 Points 4 2 7 Materials & Resources 13 Points 14 0 1 Indoor Environmental Quality 15 Points 2 0 3 Innovation & Design Process 5 Points 43 8 16 Project Totals 69 Points Notes: -Designed to LEED Silver Standard, Awarded LEED Gold in January 2010 -Achieved 36% energy Cost savings below ASHRAE 90.1 baseline

Design Objectives -Reduce Demand on Central Utility Plant Original System -Find efficiencies with Least Impact on Design Direct Use of Raw Energy Renewable Energy -Push the boundary with Available Technology Energy Storage

Photovoltaic System -Current Demand 1,000 MM BTU per month 109,000 kwh per month -PV Sizing Based on 24,000 SF Roof area Available Target: ~40% of Electricity Demand Variation: Remove Inverter Impact: Efficiency by 8% Cost by 10%

Photovoltaic System -Current Cost of Utilities $10,000-$14,000 per month depending on fuel cost $15,000 if electricity were to be purchased -PV System Cost $1,225,000 w/ Initial Tax Credits -With Depreciation, Continuous Govt. Subsidy Credits and assumed 4% increase in utility cost Breakeven within 5 Years Average utility Savings of $8,000 per Month SunPower Corp T5 Roof Tile with E19 Panel (19% Efficiency) Solar Panel +Frame + Mounting System = One Pre-Engineered Unit Quick installation, No Roof Penetration needed, 30 Year Life Guarantee, Flexibility and Durability Unparalleled

Thin Film Battery Eliminated inverter from PV System, Increased efficiency, Reduced Up Front Cost of entire System and O&M over Life of the system Draw Electricity from Storage instead of directly from PV system to Reduce Voltage spikes from PV Generation Embed Thin Film Battery Into Wall Insulation Advantages: -2x Energy Density than Commercial Supercapacitors -High Cycle Rate at High Voltage -Custom Pattern a.k.a. Cut to Fit availability -Long life Cycle (>>30,000 Cycles) with high storage efficiency -BioDegradable Disadvantages: -very New Technology -Long Lead Time -Willingness of Subcontractor to Install -Up Front Cost

Thin Film Battery Direct Use of Raw Energy Original System Energy Storage Renewable Energy Property of Product keep R-Values negligible Available in Rolls, easy transportation to Site Install between Insulation and Drywall Floats Built Into Schedule 13-22 Days per Wing (North/South) per Floor To Line the entire building : $2,160,000 For just PV System Capacity: $263,000 Cost can be Amortized into PV System No. of times of Replacement of traditional Batteries alone Could Justify the Cost $263,000 vs. $540,000 over lifetime of system

Direct Current Distribution Existing DC Based Available Systems: Electronic Ballasts Energy Management, Control System Adjustable Speed Drives for HVAC & Pumping Computer, IT Equipment Portable, Personal Electronics Inefficient power Conversions are Needed from the Building s Fixed AC Infrastructure to Power these DC Devices

Direct Current Distribution Using DC Micro Grid -Safe 24VDC at Device Interface -Enables Selective & Scalable Use -Backward & Forward Compatible -Easily Installed by Customary Trades -Promotes Alternative Energy with Higher System Efficiency Integrate Various Sources of Energy on Common Distribution Bus Simplified Direct use of DC Eliminate Multiple DC-AC and AC-DC conversion Losses

Direct Current Distribution Evaluating Lighting System on DC in FDA Building One Total Cost as Installed: $835,000 DC Systems (+25%): $1,045,000 Increased Efficiency achieved with DC: +11% Annual Utility Saving: $13,000 Simple Payback: 16 years Case Study: USGBC Headquarters -Continuous high light reflectivity acoustical ceiling -DC Multi-Channel Power Servers -Fluorescent Lighting w/ DC Ballasts -Wired Controls, Touch Panel Interface -Daylight, Occupancy, Dimming Function LEED Platinum for Commercial Interiors

Direct Current Distribution Mechanical Impact of DC Distribution System Original System Pumps on Direct Current: Direct Use of Raw Energy Renewable Energy -Reduced Head Loss, 15% More Efficient -Direct Comparison showed 10% cost saving by sizing down primary Pumps Energy Storage -Leaving Standby pumps as-is -Immediate Realization of $70,000 Saving

Conclusion Conclusion Photovoltaic System Thin Film Battery DC Distribution Practical, Cost Effective Sustainable, High Cost Worthwhile, Cost Justified

Thank You Questions? Conclusion

FDA Building One Alternative Descriptions Photovoltaic Impact Power Storage DC Distribution Systems Energy Analysis & Payback