CREEK Technical Services, LLC



Similar documents
BITUMINOUS ROOF COATINGS, CEMENTS, PRIMERS AND ADHESIVES

Quality You Can Trust Since From North America s Largest Roofing Manufacturer

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

Roof Systems Overview

Maintenance & repair Solutions

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

Table of Contents. Benefits of UNIFLEX Fluid Applied Roofing Systems 2 3. Elastomeric Finish Coats 4 5. Aluminum Finish Coats 6

CHAPTER 7: Building Systems ROOFING SYSTEMS

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

LAMA has developed over the years a wide range of products that can be used in the waterproofing

Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ 36.

Roofing Systems. New Applications / Re-Roofing / Maintenance

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

BLACK JACK ALL WEATHER ROOF COATING

After the business decisions

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

Please read the entire document before purchasing and installing any of these products


WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Commercial Roof Systems Selection Guide

MASTICS. 275 Centre St., Unit 15 Holbrook, MA (617) Shedd Rd. Middlefield, OH (440)

THE EFFECT OF REFLECTIVE ROOF COATINGS ON THE DURABILITY OF ROOF SYSTEMS

How to repair your existing low slope flat roof.

High Performance Solutions and Compounds for Roofing and Structural Waterproofing

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs

RECOATING AND RENEWING SPF ROOFING SYSTEMS

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

WATERPROOFING FOR CONCRETE STRUCTURES

COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

Colorado State University. Durrell Center Roof Repair

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

COMMERCIAL BUILDING APPLICATIONS

Durapax Coal Tar BUR Application Guide

ROOF ASSEMBLIES CHAPTER 9

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

COMMERCIAL & LOW SLOPED ROOF SPECIALISTS TOTAL NDL SYSTEM MANUFACTURER WARRANTIES

SECTION STANDING SEAM METAL ROOFING

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Roofer On-the-Job Training Guide

SECTION STORM DRAINAGE SYSTEM

Treatment of a surface or structure to resist the passage of water in the absence of hydrostatic pressure. presence of hydrostatic pressure.

CHAPTER 6 ASPHALT ROLL ROOFING

Roofing Repairs

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

FIRESTONE BUILT-UP ROOFING SYSTEMS APPLICATION GUIDE 3/14/2011

Peel & Seal Self-Stick Roofing Solutions

Maintaining Your Roof

BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC.

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Firestone Modified Bitumen Roofing Systems DURABLE. RELIABLE. SUSTAINABLE

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

The existing roof angle change terminations and flashings when sound and intact can be reused.

FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING. Asphalt Roofing Manufacturers Association

SEAMS SEAMING USING SEAM TAPE

ITEM THERMOPLASTIC MEMBRANE ROOFING

FIRESTOPPING & SMOKE SEALS

HOT ASPHALT BUILT-UP ROOFING SYSTEMS MORE LAYERS MEANS MORE PROTECTION

Minor Cracks in Horizontal Surfaces

!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!

Building Owners Guide to a Duro-Last System!

Indefinite Quantity Unit Price Schedule

Prices Effective April 1, 2016

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

Waterproof Rooftop Balconies & Decks. Or How To Keep Your Ceiling Dry When People Walk On Your Roof

USER GUIDE Easier, Safer, Betta! WATERPROOFING

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

ROOFING PRODUCTS. INSTALLATION GUIDE FOR RESISTO. Time-tested premium quality products

The Harold J. Becker Company, Inc.

Asphalt-Applied and Cold Application Built-Up Roofing Application Guide

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

Florida Building Code Approval

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

tamko.com RESIDENTIAL ROOFING PRODUCT GUIDE

USER GUIDE Easier, Safer, Betta! gripsetbetta.com WATERPROOFING

Site Inspection Report

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

COMMERCIAL ROOFING. Learning Objectives. Commercial Roofing Fundamentals May 2, 2012

Residential Roofing Guide

Crescent Valley High School Roof Investigation

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

DELTA Premium Moisture Management Systems for Foundations.

Best Practices in Roof Design: Sustainable Energy Efficient Reroofing

THERMAL AND MOISTURE PROTECTION WATERPROOFING

Detached accessory structures that contain no conditioned floor area are exempt.

ATLAS Roofing Products

FIRESTONE APP ROOFING SYSTEMS APPLICATION GUIDE TABLE OF CONTENTS

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

tamko.com RESIDENTIAL ROOFING PRODUCT GUIDE

Transcription:

EVALUATION REPORT 2010 FLORIDA BUILDING CODE Manufacturer: Henry Company Report Issued February 20, 2013 999 North Sepulveda Blvd., Suite 800 El Segundo, CA 90245 (800) 486-1278 Manufacturing Plants: Quality Assurance: Bartow, FL Scarbourgh, Ontario PRI Construction Materials Technologies (QUA9110) SCOPE Category: Roofing Subcategory: Cements-Adhesives-Coatings Code Sections: 1507.10.2, 1507.15.2, 1523.1.1 Properties: Material Standards REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) HGC-023-02-01 ASTM D 6083 2005e01 PRI Construction Materials Technologies (TST5878) HGC-147-02-01 ASTM D 1227 1995 (2007) PRI Construction Materials Technologies (TST5878) HGC-152-02-01 ASTM D 3019 1994 (2007) PRI Construction Materials Technologies (TST5878) HGC-153-02-01 ASTM D 3019 1994 (2007) PRI Construction Materials Technologies (TST5878) HGC-157-02-01 ASTM D 4586 2000 PRI Construction Materials Technologies (TST5878) HGC-158-02-01 ASTM D 4586 2000 PRI Construction Materials Technologies (TST5878) HGC-159-02-01 ASTM D 4586 2000 PRI Construction Materials Technologies (TST5878) HGC-059-02-01 TAS 114(H) 1995 PRI Construction Materials Technologies (TST5878) HGC-160-02-01 ASTM D 4586 2000 PRI Construction Materials Technologies (TST5878) HGC-163-02-01 ASTM D 4586 2000 PRI Construction Materials Technologies (TST5878) HGC-164-02-01 ASTM D 4586 2000 PRI Construction Materials Technologies (TST5878) HGC-166-02-01 TAS 139 1995 PRI Construction Materials Technologies (TST5878) HGC-170-02-01 ASTM D 1227 1995 (2007) PRI Construction Materials Technologies (TST5878) HGC-174-02-01 ASTM D 41 2005 PRI Construction Materials Technologies (TST5878) HGC-175-02-01 ASTM D 4479 2007 PRI Construction Materials Technologies (TST5878) HGC-175-02-01 ASTM D 4479 2007 PRI Construction Materials Technologies (TST5878) HGC-176-02-01 ASTM D 4586 2000 PRI Construction Materials Technologies (TST5878) HGC-177-02-01 ASTM D 4586 2000 PRI Construction Materials Technologies (TST5878) HGC-184-02-01 ASTM D 2824 2006 PRI Construction Materials Technologies (TST5878) HGC-185-02-01 ASTM D 2824 2006 PRI Construction Materials Technologies (TST5878) HGC-186-02-01 ASTM D 2824 2006 PRI Construction Materials Technologies (TST5878) HGC-187-02-01 ASTM D 2824 2006 HEN13001 FL10889 Page 1 of 5

PRODUCT DESCRIPTION & APPLICATION Unless otherwise noted, all surfaces shall be clean, dry, and free of oil, grease, rust, scale, or other debris prior to application. Unless otherwise noted, coatings are not recommended over gravel, rubber or PVC sheet roofing, shingles of any kind, nor old, dry, brittle roofs unable to withstand shrinkage stresses. Consult product data sheets for detailed application instructions. HE505 FLASHMASTER FLASHING HE906 FLASHMASTER PLUS HE208 WET PATCH TM ROOF LEAK REPAIR HE204 PLASTIC ROOF HE554 GOLD MEDAL MB FLASHING HE208R RUBBERIZED WET PATCH ROOF LEAK REPAIR HE107 ASPHALT EMULSION SEALER AND DAMPROOFER HE555 ALUMINUM HE555FR ALUMINUM HE280DC WHITE ELASTOMERIC ASTM D 4586, Type I trowel-grade flashing cement made from heavybodied asphalt reinforced with organic fibers applied 1/8-inch thick at a rate of 1 gal/12.5 ft 2. Use with asphalt coated, SBS modified, metal and masonry ASTM D 4586, Type I and ASTM D 3409 trowel-grade rubber polymer modified mastic compound of asphalt, organic fibers and mineral fillers applied to wet or dry surfaces 1/8-inch thick at a rate of 1 gal/12.5 ft 2. Use with asphalt composition, SBS modified, metal and masonry ASTM D 4586, Type I/II and ASTM D 3409 trowel-grade compound for sealing roof leaks on wet surfaces applied 1/8-inch thick at a rate of 1 gal/12.5 ft 2. Use with asphalt, BUR, SBS modified, metal and masonry ASTM D 4586, Type I trowel-grade sealant made from refined asphalt for dry surfaces. Applied 1/8-inch thick at a rate of 1 gal/12.5 ft 2. ASTM D 4586, Type I Class I, trowel-grade rubberized flashing cement designed for use with SBS modified bituminous roofing and asphalt coated membranes. Applied at a rate of 1 gal/ 12.5 ft 2. ASTM D 4586, Type I Class II and ASTM D 3409, trowel-grade SBS modified bitumen used for repair of roof leaks on wet surfaces. Applied at a rate of 1 gal/ 12.5 ft 2. Use with asphalt, BUR, SBS modified, metal and masonry ASTM D 1227, Type II Class I, brush/spray-grade asphalt emulsion coating used for maintenance of roofing materials applied at a rate of 3-4 gal/ 100 ft 2. Use with composition ASTM D 2824, Type III, fibered aluminum roof coating used for maintenance of roofing materials. Applied at a rate of 1.25-2.0 gal/ 100 ft 2. Use with asphalt, BUR, modified bituminous, and weathered galvanized and tin ASTM D 2824, Type III, applied at a rate of 1.25-2.0 gal/ 100 ft 2. Use with asphalt, BUR, modified bituminous, metal, and primed masonry ASTM D 6083 water-based acrylic latex coating. Application rates are as follows: Smooth Surfaces: 2 to 2-1/2 gal/100 ft 2 applied in two coats Mineral Cap Sheet: 2 to 3 gal/ 100 ft 2 applied in two coats Use with concrete, galvanized steel, SBS modified, BUR, EPDM, and PVC. HEN13001 FL10889 Page 2 of 5

HE289 WHITE ROOFING SEALANT HE553 MBA GOLD MODIFIED BITUMEN ADHESIVE HE201 FIBERED BLACK ROOF COATING HE910-01 ASPHALT PRIMER PRO-GRADE ALL WEATHER FLASHING #27; PRO-GRADE ALL WEATHER FLASHING #225 PRO-GRADE SILVER MEDAL MB FLASHING #531 ELASTOMERIC PRO-GRADE 226 PLASTIC ROOF PRO-GRADE 812 FIBERED ALUMINUM PRO-GRADE 832 FIBERED ALUMINUM TAS 139, white, elastomeric patching compound used for repair of roof leaks prior to coating. Applied at a rate of 1 gal/ 12.5 ft 2. Use with SBS modified, metal, and masonry ASTM D 3019, Type III, fibrated rubberized adhesive for use with adhering modified bituminous and asphalt coated membranes. Applied at a rate of 1.5 gal/ 100 ft 2. ASTM D 4479, Type I, brush or spray-grade used for maintenance of roof materials. Applied at a rate of 1.5 gal/ 100 ft 2. Use with metal, SBS modified, or composition ASTM D 41 Type II, asphalt primer for use with smooth surface roofs, concrete, masonry, brick, and metal surfaces. Applied at a rate of 1 gal/200 ft 2. ASTM D 4586, Type I Class II and ASTM D 3409, trowel-grade flashing cement for sealing roof leaks on dry or wet surfaces applied at a rate of 1 gal/ 12.5 ft 2. ASTM D 4586, Type I Class I, trowel-grade plastic roof cement applied 1/8-inch thick at a rate of 1 gal/ 12.5 ft 2. Use with asphalt, metal and composition roof surfaces. ASTM D 2824, Type III, coating for use with smooth surface asphalt built-up and modified bitumen membranes applied at a rate of 1 gal/ 75 ft 2 1.5 gal/ 100 ft 2. ASTM D 2824, Type I coating for use with smooth surface asphalt built-up and modified SBS and APP bitumen membranes. Application rates are as follows: Smooth Surfaces: 0.25-0.33 gal/ 100 ft 2 Mineral Cap Sheet: 0.33-0.5 gal/ 100 ft 2 Masonry and smooth surface SBS and APP roofs surfaced with hot asphalt must first be coated with fully-cured asphalt emulsion. PRO-GRADE 842 FIBERED ALUMINUM PRO-GRADE 331 COLD PROCESS ROOF ADHESIVE PRO-GRADE 441 FIBERED ROOF COATIING ASTM D 2824, Type III, coating for use with built-up asphalt, prepared roll roofing, smooth surface modified bitumen membranes, weathered galvanized iron or tin applied at a rate of 1.25-2.0 gal/ 100 ft 2. ASTM D 3019, Type III, brush-grade, cold-applied, adhesive for use with asphalt coated or self-adhering modified bitumen products applied at a rate of 2 gal/ 100 ft 2. ASTM D 4479, Type I, heavy-bodied asphalt coating reinforced with fiber applied at a rate of 2 gal/ 100 ft 2. Use with asphalt, metal and composition roofs HEN13001 FL10889 Page 3 of 5

PRO-GRADE 535 SILVER MEDAL MBA MODIFIED BITUMEN ADHESIVE PRO-GRADE 162 FIBERED ASPHALT EMULSION BULL 100 PREMIUM ALUMINUM ROOF COATING BULL 900 SPECIAL FLASHING BULL 700 PLASTICE ROOF BULL 200 ASPHALT PRIMER SL1100- SUNNILAND PLASTIC SL1400 SUNNILAND PREMIUM MODIFIED SL1300 SUNNILAND ALL WEATHER FLASHING PR300 PREMIER PLASTIC ROOF PR350 PREMIER WET OR DRY PLASTIC ROOF PR400 PREMIER COLD PROCESS ADHESIVE ASTM D 3019, Type III, fibrated, rubberized adhesive for use with SBS modified bitumen and asphalt-coated membranes applied at a rate of 1.5 gal/ 100 ft 2. Not to be used with SBS membranes single ply with polyethylene backing or APP products. ASTM D 1227, Type II Class I, brush/spray-grade coating of an asphalt base with a clay emulsion that contains mineral fibers for use in damp proofing new or existing asphalt roofs, galvanized or ungalvanized metal, composition roofing or periodic maintenance recoating applied in two coats at a rate of 3-5 gal/ 100 ft 2 /coat. ASTM D 2824, Type III, coating used for smooth surface asphat builtup, modified bitumen membranes and metal applied at a rate of 1 gal/ 75 ft 2-1 gal/ 100 ft 2. compound for roof flashings applied to wet or dry surfaces 1/8-inch thick at a rate of 1 gal/ 12.5 ft 2. ASTM D 4586, Type I Class I, trowel-grade mastic compound applied 1/8-inch thick at a rate of 1 gal/ 12.5 ft 2. Not for use over coal tar. ASTM D 41 Type II, solution of asphalt base in a petroleum solvent applied at a rate of 0.5 gal/ 100 ft 2. ASTM D 4586, Type I Class I, trowel-grade mastic compound for vertical and horizontal applications applied 1/8-inch thick at a rate of 1 gal/ 12.5 ft 2. For use repairing leaks on metal roofs, shingles, composition roofing and asphalt. ASTM D 4586, Type I Class I, trowel-grade mastic compound applied to wet or dry surfaces 1/8-inch thick at a rate of 1 gal/ 12.5 ft 2. For use repairing leaks on metal roofs, shingles, concrete, masonry and brick. Not for use over coal tar. compound for wet or dry surfaces applied 1/8-inch thick at a rate of 1 gal/ 12.5 ft 2. For use repairing leaks on metal roofs, shingles, concrete, masonry and brick. Not for use over coal tar. ASTM D 4586, Type I Class I, trowel-grade mastic applied 1/8-inch thick at a rate of 1 gal/ 12.5 ft 2. For use with asphalt, metal and composition compound for wet or dry surfaces applied 1/8-inch thick at a rate of 1 gal/ 12.5 ft 2. For use repairing leaks in composition, mineral surface cap sheet, asphalt coated, SBS modified, metal, roofs, shingles, concrete, masonry and brick. ASTM D 3019, Type III, cold-applied asphalt roofing adhesive applied at a rate of 2 gal/ 100 ft 2. PR550 PREMIER ALUMINUM ROOF COAT ASTM D 2824, Type III, coating for use on smooth surface asphalt built-up, metal and modified bitumen membranes applied at a rate of 1-1.2 gal/ 100 ft 2. HEN13001 FL10889 Page 4 of 5

ROOFER S CHOICE ASPHALT EMULSION ASTM D 1227, Type II Class I, brush/spray-grade coating for smooth surfaces applied in one coat or at right angles in two coats at a rate of 3 gal/ 100 ft 2 /coat. LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. Structural integrity of the roofing substrate or assembly is not within scope of this evaluation. Refer to the appropriate product approval for installation of these components within an Approved roof assembly. 3. Installation of the evaluated products shall comply with this report and the manufacturer s published application instructions. 4. Applications are valid for new and existing roof systems. COMPLIANCE STATEMENT The products evaluated herein have demonstrated compliance with the 2010 Florida Building Code as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT HEN13001 FL10889 Page 5 of 5